HomeMy WebLinkAboutPLBG2023-002580ADDRESS 3000 Grapevine Mills Pkwy., 519 Grapevine, TX 76051 LEGAL City Of Blk 15 Lot C S 1grapevine PERMIT HOLDER Clayton Robinson CR Plumbing (940) 367-3778 COLLABORATORS •Clayton Robinson CR Plumbing (940) 367-3778 OWNERS •Grapevine Mills Mall Lp (317) 636-1600 TENANTS •Legoland Discovery Center INSPECTIONS 15 1. MISC. Plumbing Inspection 2. Plumbing Rough In 3. Plumbing Sewer 4. Plumbing Shower Pan 5. Plumbing Top Out 6. Plumbing Tub Seal 7. Plumbing Water Service 8. Plumbing Gas Service 9. Plumbing P-Trap 10. Plumbing Temp Gas 11. TCEQ Backflow Certification Submit 12. Backflow Device Inspection 13. Plumbing Customer Sevice Inspection 14. Plumbing Water Heater 15. Plumbing Final INFORMATION FIELDS **APPLICANT NAME (Individual)Clayton Robinson **APPLICANT PHONE NUMBER 9403673778 VALUATION 4505 TCEQ TCEQ Blank Form.pdf FEE TOTAL PAID DUE Plumbing Permit Fee {VALUE}$ 72.00 $ 72.00 $ 72.00 TOTALS $ 72.00 $ 72.00 $ 0.00 READ AND SIGN I HEREBY CERTIFY THAT THE FOREGOING IS CORRECT TO THE BEST OF MY KNOWLEDGE AND ALL WORK WILL BE PERFORMED ACCORDING TO THE DOCUMENTS APPROVED BY THE BUILDING DEPARTMENT AND IN COMPLIANCE WITH THE CITY OF GRAPEVINE CODES REGULATING CONSTRUCTION. IT IS UNDERSTOOD THAT THE ISSUANCE OF THIS PERMIT DOES NOT GRANT OR AUTHORIZE ANY VIOLATION OF ANY CODE OR ORDINANCE OF THE CITY OF GRAPEVINE. I FURTHER CERTIFY THAT ALL WORK THAT IS REQUIRED TO COMPLY WITH ANY FEDERAL, STATE, AND / OR LOCAL LAW REGARDING ENERGY CONSERVATION WILL BE PERFORMED IN ACCORDANCE WITH THOSE LAWS, AND THAT VERIFICATION OF ENERGY CODE COMPLIANCE SHALL BE SUBMITTED TO THE CITY UPON REQUEST. July 17, 2023 City of Grapevine PO Box 95104 Grapevine, Texas 76099 817) 410-3166 Plumbing Permit {VALUE} Project # 23-002580 Project Description: Replace 1/2" RPZ for Legoland in the utility room "Legoland" Issued on: 07/17/2023 at 5:33 PM MYGOV.US 23-002580, 07/17/2023 at 5:33 PM Issued by: Connie Cook Page 1/2 Signature Date City of Grapevine Plumbing Permit {VALUE} Project # 23-002580 NOTICES ALL work must be done in compliance with the 2006 INTERNATIONAL PLUMBING CODE. PLAN SUBMITTAL: WHEN PLANS ARE REQUIRED BY CODES, ORDINANCES, OR AS DETERMINED BY THE BUILDING OFFICIAL, THREE (3) SETS OF PLANS SHALL BE SUBMITTED IN HARD COPY FORMAT. ENGINEER SEALED PLANS AND CALCULATIONS SHALL BE SUBMITTED AS REQUIRED BY CODES, ORDINANCES OR WHERE OTHERWISE REQUIRED BY STATE LAW. NOTES > 24 HOUR INSPECTION NUMBER METRO (817) 410-3010, CUT OFF TIME FOR A.M. INSPECTION IS 7:30 A.M. --- CUT OFF TIME FOR P.M. INSPECTION IS 12:30 P.M. > PERMIT ISSUED IN ACCORDANCE WITH APPLICATION ON FILE IN THIS OFFICE. THIS PERMIT SHALL EXPIRE IF WORK IS NOT COMMENCED WITHIN (180 DAYS) OF ISSUANCE OR IF WORK IS SUSPENDED OR ABANDONED FOR A PERIOD OF (180 DAYS). THE ISSUANCE OR GRANTING OF THIS PERMIT AND / OR APPROVAL OF PLANS, SPECIFICATIONS AND COMPUTATIONS SHALL NOT BE CONSTRUED TO BE A PERMIT FOR, OR AN APPROVAL OF, ANY VIOLATION OF ANY OF THE PROVISIONS OF THE CODES AND ORDINANCES OF THE CITY OF GRAPEVINE. THE ISSUANCE OF A PERMIT BASED ON PLANS, SPECIFICATIONS, AND OTHER DATA SHALL NOT PREVENT THE BUILDING DEPARTMENT FROM THEREAFTER REQUIRING THE CORRECTION OF ERRORS IN SAID PLANS, SPECIFICATIONS, AND OTHER OR REQUIRING CORRECTIONS OF THE CONSTRUCTION ITSELF. MYGOV.US 23-002580, 07/17/2023 at 5:33 PM Issued by: Connie Cook Page 2/2 Texas Comvnl,,;,ion on Envii-onment-d Quality BACKFLOW PREVENTION ASSEMBIATESTAND MAINTENANCE REPORT tor -',t-'h i-cw N% A ilq,?ai ard d,i:L,.-01,, 1 J \,--\NTIE OF PWS: PWS jr.)qf: PW S \ 1A I L IN"(1 ADDR ES S: PWS CONTACT PERSON: ADDIRVISS 01"SURVICE: '?)CM (�akpwi(\e i-k-A\5 ��,,)t ['tic kwkllow o'evention asscillblv detailed heloA has been tested and maintained as I-eLjLlh,cd by commission rek,ulaticatl 110d 1, ccrtified to be operall 111- -xvith ill acceptable parameters. TYPE OF BACKI'LOW PICE VEN'rICES ASSEMBIAMPU Rcduccd I'l-essure Principle (RPBA) [I Reduced Pressure Principle -Detector (RPBA-D) Type 11 El El Double Clleck Valve (DCV-A) Double Check -Detector (DCVA-D) Type If 11 PI-eSSUre Vacuum Breaker (PVB) i f--j Spill-Resi,,,tart Pressure VaCLILIM Breaker (SVB) MUllff-KALII-Cr: i Main: Wakj-7,, 13} pass: i size: Vic, Main: 11 y pass: Model Number N41ill: LFC0qQ-F B\pa.,,s: BPA Location: Sen;fl Nmuhcr Main: a,'571-,>10 B p., Rcas011 R)" test: Ncxv Existing El Replacement El Old Model/Serial # k the assembP, insualled ill accordance with imanufacturer recommendations andlor local codes" c, ❑ N k tile 'Isscillbl" installed oil a non -potable water supply tauxiliary)" El IRepah-s 3nd IMaterials I -`. , M,ter Ale- R i —1i r Date: "Thule: 4RCdLICCd PrCSSLII-C Principle Assembly (RPBA,) DCVO Reliet'Valve 1' Check 1 2`1 Check. - Held -it 0 psid Held at 7. t psid Opciied al'31 -Nr ja PSid Closed "wilt Clo,�ed Tipla Leaked 11 Leaked El Did not I open Main: By1m,"Z: Held at Psid Held at — psid Ope ClosedTight El P`�id Ch 1 Z7 I) tie I I A,,sembly 13\pass Check, Held at ( losc°dTight Leaked Held at Closed Ti,-,hL F-1 PVB SN, B Air Inlet Chek val,e psid Opened ,at — psis] Held ai 11 I'lid taut open El El Did it fall' ()Pell Leaked (Yes F1 /No 0) Psid Openedal — 17sid Held at 1`6 check,: numeric readim-, rem ired for DCVA only Differential pressure iyaUlle used: Potable: Non -Potable: El j SN, aD,te tested for accurac y Re €zltszks: Company Name: Licensed Tester Name l,PrintfFvpe): Compaw, Addi-ess: -C), Licensed Tester Name (Signatut CollipaI1) plione #: BIPAT License License Expiration Date: Z. ZT -L& The above is certified to be true at the time of testing. I L'STRFCORDS NIUSTBL KEPT FOR ATI,EAs'rTHREE YEARS 130 TAU290,46l B)l USFONI A ylANI TACTUREWS R::PI.,,\Cl-',%IENT I-IAR,rs TCEQ-20700 (Revision 04-04-2019) Pa,-,e I of I