Loading...
HomeMy WebLinkAboutPLBG2023-002581ADDRESS 3000 Grapevine Mills Pkwy., 525 Grapevine, TX 76051 LEGAL Grapevine Mills Addition Blk 1 Lot 1r3 S Sea Life Center Aquarium PERMIT HOLDER Clayton Robinson CR Plumbing (940) 367-3778 COLLABORATORS •Clayton Robinson CR Plumbing (940) 367-3778 OWNERS •Grapevine Mills Mall Lp (317) 636-1600 TENANTS •Sea Life Center Aquarium (212) 512-9600 INSPECTIONS 3 1. TCEQ Backflow Certification Submit 2. Backflow Device Inspection 3. Plumbing Final INFORMATION FIELDS **APPLICANT NAME (Individual)Clayton Robinson **APPLICANT PHONE NUMBER 9403673778 VALUATION 4505 Square Footage 35157 TCEQ TCEQ Blank Form.pdf FEE TOTAL PAID DUE Plumbing Permit Fee {VALUE}$ 72.00 $ 72.00 $ 72.00 TOTALS $ 72.00 $ 72.00 $ 0.00 READ AND SIGN I HEREBY CERTIFY THAT THE FOREGOING IS CORRECT TO THE BEST OF MY KNOWLEDGE AND ALL WORK WILL BE PERFORMED ACCORDING TO THE DOCUMENTS APPROVED BY THE BUILDING DEPARTMENT AND IN COMPLIANCE WITH THE CITY OF GRAPEVINE CODES REGULATING CONSTRUCTION. IT IS UNDERSTOOD THAT THE ISSUANCE OF THIS PERMIT DOES NOT GRANT OR AUTHORIZE ANY VIOLATION OF ANY CODE OR ORDINANCE OF THE CITY OF GRAPEVINE. I FURTHER CERTIFY THAT ALL WORK THAT IS REQUIRED TO COMPLY WITH ANY FEDERAL, STATE, AND / OR LOCAL LAW REGARDING ENERGY CONSERVATION WILL BE PERFORMED IN ACCORDANCE WITH THOSE LAWS, AND THAT VERIFICATION OF ENERGY CODE COMPLIANCE SHALL BE SUBMITTED TO THE CITY UPON REQUEST. July 18, 2023 Signature Date City of Grapevine PO Box 95104 Grapevine, Texas 76099 817) 410-3166 Plumbing Permit {VALUE} Project # 23-002581 Project Description: Install a 1/2-inch RPZ in the kitchen for the soda machine. [Install RPZ above sink] "Sea Life Center Aquarium" Issued on: 07/18/2023 at 8:53 AM MYGOV.US 23-002581, 07/18/2023 at 8:53 AM Issued by: Connie Cook Page 1/2 City of Grapevine Plumbing Permit {VALUE} Project # 23-002581 NOTICES ALL work must be done in compliance with the 2006 INTERNATIONAL PLUMBING CODE. PLAN SUBMITTAL: WHEN PLANS ARE REQUIRED BY CODES, ORDINANCES, OR AS DETERMINED BY THE BUILDING OFFICIAL, THREE (3) SETS OF PLANS SHALL BE SUBMITTED IN HARD COPY FORMAT. ENGINEER SEALED PLANS AND CALCULATIONS SHALL BE SUBMITTED AS REQUIRED BY CODES, ORDINANCES OR WHERE OTHERWISE REQUIRED BY STATE LAW. NOTES > 24 HOUR INSPECTION NUMBER METRO (817) 410-3010, CUT OFF TIME FOR A.M. INSPECTION IS 7:30 A.M. --- CUT OFF TIME FOR P.M. INSPECTION IS 12:30 P.M. > PERMIT ISSUED IN ACCORDANCE WITH APPLICATION ON FILE IN THIS OFFICE. THIS PERMIT SHALL EXPIRE IF WORK IS NOT COMMENCED WITHIN (180 DAYS) OF ISSUANCE OR IF WORK IS SUSPENDED OR ABANDONED FOR A PERIOD OF (180 DAYS). THE ISSUANCE OR GRANTING OF THIS PERMIT AND / OR APPROVAL OF PLANS, SPECIFICATIONS AND COMPUTATIONS SHALL NOT BE CONSTRUED TO BE A PERMIT FOR, OR AN APPROVAL OF, ANY VIOLATION OF ANY OF THE PROVISIONS OF THE CODES AND ORDINANCES OF THE CITY OF GRAPEVINE. THE ISSUANCE OF A PERMIT BASED ON PLANS, SPECIFICATIONS, AND OTHER DATA SHALL NOT PREVENT THE BUILDING DEPARTMENT FROM THEREAFTER REQUIRING THE CORRECTION OF ERRORS IN SAID PLANS, SPECIFICATIONS, AND OTHER OR REQUIRING CORRECTIONS OF THE CONSTRUCTION ITSELF. MYGOV.US 23-002581, 07/18/2023 at 8:53 AM Issued by: Connie Cook Page 2/2 1'exas Corni-tilssion cart Elivironniental QtialitN BACKFLOW PREVENTION ASSEMBLYTEST AND MAINTENANCE REPORT I f1v Wrn� mw,' be omo,cwd tur ,a A atiwwbh tcme,L A izned and dated vrk6nai niLl't bo-suhmiucj to :hc puNIC k.,Io unphT 1,,s A PPS 09: PWS \'JAIUNGADDRESS: PNVS CON TAC' I'PERSON: ADDRESS OF St"RVICT: The backilow pi-evetitioti a-�senibly deLailed below ha.k; becii tested and inaintain I as i-eLlUii-cd by coinniiNsioii rellUlatioll" and's cei-tified to be operatnio W11,11illacceptable paranicteis. TYPE OF BACKFLOWPRE'ELATION ASSEMBLY (BPA): Rediiced P1'e-,1;Ul-e Priticiple (RPBA) ❑ iRedLicedPreS,LtrePi-iticil)le-Detect(-)rtRPBA-D) Type 110 El Dotibic Check 'Valve (D(.'.V.zk) El Double Check -Detector (DCVA-D) Type 11 El PrCSSUI-C VaCLAWn Breaker (PVB) ❑ Spill -Resistant Pressure Vacutlin Bi-eaket- (SVB) Size: VI-" %lodcl NUMI-)CE L BPALocation: NLMJOCI-: NI'lini S7clz-185Z BP A 1, Reason t'01' ICA: Ne", Existing El Replacenient El Old kfodel/Sei-ial # ls the a.t;selllbk installed ill accoirdance with inatiitf'aclurcr i-econiniendallonsand/or local codes'! DR"Yes El No V, t1b, lasiniled can at 11011-POtable Watel-SUPply (111[Xiliat'V)'? I'ESTRESULT1 Type 11 IRCdUCCd PJ-e',SU1-e Pt-inciple Assen-ibly (RPBA) P VB � S VB PASS DCVA Relict'valve 13\.passCbo,,k It =\ii lillea ill Clie,k Vake Ithl 2 Cbeck--** FAIL El I"Clieck InitialTest I 1-1clo a! JC) paid I-leldat Cl.?- psid Ot)ened at 44.O HeWai psidjOpelled at laid I leld at k-of Tit-,N 5�r cjosed,riLta Ulost,dTighi F-1 Did not opcii El Did bot Led,ed ❑ ;31 k�,ikcd El Leaked 0 Leaked 0 Did it I'Lilly open lac t1 (Yes f-1 /No 0) Repairs and :\1 I 111: it Test Arter psid Held at 'Held Lit sid'Opened at I Held, at psid Opened at Held at i — — p psid 1�c �)air lClo,,ed,riglit 11 CIk--),�edTi,,h1 El psid Closed psid Date: Cl 2"" check: [ILMICI-IC i-eading I-C(11,tired for DCVA oniv -Clitial pl-esstll-e L!alloe LlSed: 5 Potable: aAoc- Non -Potable: D 1. ly-qq E SN NCO Date tested fi-lraccuracy lilad's: Conipam Nanie: Licenscel Tester Naine tYtt (Pi-int/Tvpc)- Conipany Addi-ess: 2-7 License(I-Fe,,,tei,Naiiiie(,SignittLil-ee: zz k m1palIN, Pbolle BPAT License if E I q t,�5 qqO-' SD7,277a,, License Expii�ation Date: -L -L7- V, The above is certified to be true at the time of testing. I:TFSTRf-,CORDS NIU'STBE KEPT FOR AT LEAST THREE `t'EARS 130TAC §290.46(13)1 I !SF ONLY MINI 1FACTUIRFR'S R 1: Ill, ACI`Al F,' NT PARTS TCF0-20-100 (Rey sion 04-04-2019) Paze I of' I