Loading...
HomeMy WebLinkAboutPMISC2023-002693ADDRESS 3326 Clearfield Dr. Grapevine, TX 76051 LEGAL Countryside Estates Addition Blk 10 Lot 24 A24 S220 10 *04785061* PERMIT HOLDER Shannon Rockett Mr Rooter DFW (214) 339-9000 COLLABORATORS •Shannon Rockett Mr Rooter DFW (214) 339-9000 OWNERS •Reynaud, Otis W INSPECTIONS 2 1. TCEQ Backflow Certification Submit 2. Plumbing Final INFORMATION FIELDS **APPLICANT NAME (Individual)Mark McGaughy **APPLICANT PHONE NUMBER 2143399000 VALUATION 2500 FEE TOTAL PAID DUE Plumbing Miscellaneous Fee $ 37.00 $ 37.00 $ 37.00 TOTALS $ 37.00 $ 37.00 $ 0.00 READ AND SIGN I HEREBY CERTIFY THAT THE FOREGOING IS CORRECT TO THE BEST OF MY KNOWLEDGE AND ALL WORK WILL BE PERFORMED ACCORDING TO THE DOCUMENTS APPROVED BY THE BUILDING DEPARTMENT AND IN COMPLIANCE WITH THE CITY OF GRAPEVINE CODES REGULATING CONSTRUCTION. IT IS UNDERSTOOD THAT THE ISSUANCE OF THIS PERMIT DOES NOT GRANT OR AUTHORIZE ANY VIOLATION OF ANY CODE OR ORDINANCE OF THE CITY OF GRAPEVINE. I FURTHER CERTIFY THAT ALL WORK THAT IS REQUIRED TO COMPLY WITH ANY FEDERAL, STATE, AND / OR LOCAL LAW REGARDING ENERGY CONSERVATION WILL BE PERFORMED IN ACCORDANCE WITH THOSE LAWS, AND THAT VERIFICATION OF ENERGY CODE COMPLIANCE SHALL BE SUBMITTED TO THE CITY UPON REQUEST. July 26, 2023 Signature Date City of Grapevine PO Box 95104 Grapevine, Texas 76099 817) 410-3166 Plumbing Permit - MISC Project # 23-002693 Project Description: installing double check valve Issued on: 07/26/2023 at 10:39 AM MYGOV.US 23-002693, 07/26/2023 at 10:39 AM Issued by: Connie Cook Page 1/2 AC PLOW PRENENTION ASSEMBI,Y'I'ESI'ANDN,IAINTI.'NANCE REPOM' Thc fi4lowin4 .�fonfl uItINI IV cojjlplxtcd fore", h a , �,twiht te�wdA A�L:Iml and dated ori0n;d mut N-1 a.mhimltvd to tl mipplier for mmrAwc ltt^ cater I e% NAME OF PWS- Citv of Grat)evine PPS IN: 2260013 PWS NMAILING ADDRESS- 1P0 Box95104 Grapevine, TX 76099 C 4 P\\,*,s coN,rAcr PERSON: ADDRE-SS OF SERVICE: Current Resident 3326 Clearfield Dr Grapevine. TX 76051 The backtlow prevention assembly detailed below has been tested -,aid maintaincolas required by conanission regulatiows and is certit' ted to be operating, wit hinacceptable paranicters. `TYPE OF BACKFLOW PREVENTiON ASSEMBLY (811A.): Reduced Pressure Prineil)le (R09A) Reduced Pressure Principle -Detector ('RPBA-D) Type 110 Double Check Valve (DCVA) E] Double Check -Detector (DCVA-D) Tyler, 110 Pressure Vacuum Breaker (PVB) SDill-Resistaw Pressure Vacuum Breaker (SVf3) 5-11,1111facturer: :shrill -Watts N,pass: Size: Main: 3/4" 13%,Pass� I BPA U�catit n At meter .%'LF007M3QT Bypass: Model Number: fi ain Serial Mimi: Bypxss.� Niaill-214184 BP..�Serves: 7irriqation I Reason for test- New 0 E, K i s tit —n�, 0 I Replacement El Old McKlel/Serial # ? ? 1 Is theassembly installed inaccordance with manufacturer recommendations and/or hxal codes? Yes No 1 Is tile assellibls, installed oil a non-jx)tablewatcr sul)I)IN (auxiliaq)? D Yes E I N' TESTRESULT Reduced Pressure Princil)le Assenibly (RPBA) Assembly PVB & SVB PASS DCVA FAIL C3 I" Check 21 Check Reliel'Valve Bypass Check Air Inlet Check Valve Re " "' Vaive 2' if �l IllitialTest Illeld.k12.3 psid lieldat psid Opened at I leld at psid Opened psid field at Did Date: 08-01-23 Clotwd Tight Closed Tirlit psid Cloy, Tight 0 Did not open �id Time: 7:45 AM Did not C3 Did it fully open naked 0 Leaked El Leaked 0 Uaked o )L lvil 0 Yes C1 /No CI) Repairs and Main: Materials Used*,", Bypass: Test After Held at — psid field at 1)sid Openedat_ lieldat_psiol Opened at_psid lIe1dat___ 11mair ClosedTight 0 Closed Tight 0 psid Closed p4d Date: Tight 0 Time: check: numeric reading intred t, r DCVA on.V . Differential pressure gaug-e used: Potable: Non -Potable: 0 )t '(I)for ac-Potable: 09-23-2022 ""iae" pressure 06plt7 Z3 Datetesw oraccurac Mlake/Model: Wilkins TG-5 Sid: nR171inq Company NaActive Backfiow Licensed Tester Name (Printfryrle): John An fee,101 Licensed Tester Name (Signature): Conilmny Address: 611 N IH 35E., Suite 4 Carrollton, TX 75006 Company Phone #: 972-242-2229 'Fj) K—r License ­# License )iralion Date, _j 04-04-26 -f—he aboveiscertifled to I)e true at the three of testing. *'ITSTRECORDS MUST BE KEPTFOR A,r LEAST THREE YEARS I30'I*AC §290.46(B)j -": USE ONLY NIAN111,ACTURER'S REJILACUMENTPAR'I'S TCPO. )(IVO i Pev;6nn W,-01-10 10 1 pnog I of I