Loading...
HomeMy WebLinkAboutPLBG2023-003219ADDRESS 1211 W Northwest Hwy. Grapevine, TX 76051 LEGAL Westview Business Park Blk 1 Lot 1a S Car Wash Grapevine Location c/o Kimball Rd., L.P. PERMIT HOLDER Crockett / Patterson Crockett Patterson Const ruction & Plumbing, Inc (121) 476-3730 (3) COLLABORATORS •Crockett / Patterson Crockett Patterson Construction & Plumbing, Inc (121) 476-3730 (3) OWNERS •Kimball Road Lp TENANTS •Car Wash Grapevine Location c/o Kimball Rd., L.P. INSPECTIONS 3 1. TCEQ Backflow Certification Submit 2. Backflow Device Inspection 3. Plumbing Final INFORMATION FIELDS **APPLICANT NAME (Individual)Crockett Patterson **APPLICANT PHONE NUMBER 2147637303 VALUATION 1794 Square Footage 4500 FEE TOTAL PAID DUE Plumbing Permit Fee {VALUE}$ 57.00 $ 57.00 $ 57.00 TOTALS $ 57.00 $ 57.00 $ 0.00 READ AND SIGN I HEREBY CERTIFY THAT THE FOREGOING IS CORRECT TO THE BEST OF MY KNOWLEDGE AND ALL WORK WILL BE PERFORMED ACCORDING TO THE DOCUMENTS APPROVED BY THE BUILDING DEPARTMENT AND IN COMPLIANCE WITH THE CITY OF GRAPEVINE CODES REGULATING CONSTRUCTION. IT IS UNDERSTOOD THAT THE ISSUANCE OF THIS PERMIT DOES NOT GRANT OR AUTHORIZE ANY VIOLATION OF ANY CODE OR ORDINANCE OF THE CITY OF GRAPEVINE. I FURTHER CERTIFY THAT ALL WORK THAT IS REQUIRED TO COMPLY WITH ANY FEDERAL, STATE, AND / OR LOCAL LAW REGARDING ENERGY CONSERVATION WILL BE PERFORMED IN ACCORDANCE WITH THOSE LAWS, AND THAT VERIFICATION OF ENERGY CODE COMPLIANCE SHALL BE SUBMITTED TO THE CITY UPON REQUEST. September 06, 2023 Signature Date City of Grapevine PO Box 95104 Grapevine, Texas 76099 817) 410-3166 Plumbing Permit {VALUE} Project # 23-003219 Project Description: Replacing (1) 1-1/2'' RPZ device inside the mechanical closet for the car wash water system. NOT irrigation.(Self Service Carwash) "Kimball Rd. LLC" Issued on: 09/06/2023 at 2:10 PM MYGOV.US 23-003219, 09/06/2023 at 2:10 PM Issued by: Connie Cook Page 1/2 Texas Commission on Environmental Quality BACKFLOW PREVENTION ASSENIBLYTESTAND NIAIN'tENANCE REPORT The followin., fonn mum be coms�Ieted furvach tested. A si.-Iicd and (Lilvd oriAml inua be submitted to the f,ublic water swl in NAME6F OWS: lcitv of Grapevine SEP PWS ID#: :2200013 PWS MAILING ADDRESS: :PO Box 95104 Grapevine, TX 76099 PWS CONTACT PERSON: ADDRESS OF SERVICE: Gra,,��evine Carwash 1211 W Northwest HWY Grapevine TX 76051 T lie backilow prevention assembly detailed below has been tested and Maintained as required by commission regulations and is certified to be olvratim-, within acceptable parameters. 11'YPE OF BACKFLOW PREVENTION ASSE-14111,Y (BPA): Reduced Pressure Principle (RPBA Reduced Pressure Principle -Detector (RPBA-D) Type 110 Double Check Valve (DCVA) Double Check -Detector (DCVA-D) Type 110 E] •Pressure Vacuum Breaker (PVB) Spill -Resistant Pressure Vacuum Breaker.,(SUB) I Main: Main: 1-1/2" Byp.-ks,;: anUfacturer: Bypass: Size: BPA Location: in meth room Model Number: Maii':LF009M2QT Bypass: Serial . BPA Serves: :mainline Number Maiii:092768 Bypass,: Reasoil for test: New 0 Existing 13 Rei dacenient 0 Old Model/Serial 4 153553 009M2QT Is the assembly installed in accordance With Inaffil fact Lire r recommendations and/or local codes'? IZI Yes D No Is the assembly installed on a non -potable water supply (auxiliary)? El Yes M No TEST ]RESULT Type It �j Reduced Pressure Principle Assembly (RPBA) �i Assembly !I PVB & SVB PASS 0 DCVA 15 Relief Valve Bypass Check Air Inlet Check Valve FAIL 0 I" Check i� 2n' Check*** jl Initial Test .............. Held at 9.0 psid Held ;It 8 ps .9 id !,�ODejjod at 2.9 Iteld at psid, Opencdat Jleldat 08-2-8-23 C I oxd Ti lit Closed Tiolit d Did not Closed Tight 1� Did not open El psid 'Did it fully open 11,xaked Time: 1:00 PM Leaked Ej Lcak-ed �U-aked [:3 Open li(Ye- INO Repairs and Mai 11 Materials Used** Bypass: Test After Held at — paid i, Held at psid Held at Opened at �? psid Opened at paid Held at Revair Closed Ti-ht D Closed Tight paid aiClosed;,paid Date: Tight 11 Ti nie: check: nurneri re ing C ad re(;uircd for DCVA onl�, Differential pressure gauge used: Potable: Z Non -Potable: LMakcIM1o4Fl:. TG-5 !06171303 Date tested for accuracL. -23-2022 L09111 1. 11 Remarks: Company Name; ::A & A Active Backflow Licensed Tester Name (Priq/T` pe�)John P V1919y Company Address: 1611 N 1H 35E., Suite 410 Licensed Tester Name (Signature): ,Carrollton, TX 75006 �BPO Company Phone #: BPAT License O06162-# License Expiration Date: 104-04-26 The above Is certified to be true at the time of testing. TEST RECORDS MUST OE KEPT FOR AT LEAST THREE YEARS 130 TAC k290.46(B)l ** USE ONLY MANUFACTURER'S REPLACEMENT PARTS TCEQ-20700 (Revision 04-04-2019) Page I of I