Loading...
HomeMy WebLinkAboutPLBG2023-002958ADDRESS 1517 Brookwood Dr. Grapevine, TX 76051 LEGAL Dove Landing Addition Blk 1 Lot 20 S *05787556* PERMIT HOLDER Shannon Rockett Mr Rooter DFW (214) 339-9000 COLLABORATORS •Shannon Rockett Mr Rooter DFW (214) 339-9000 OWNERS •Blake, Jennifer L INSPECTIONS 3 1. TCEQ Backflow Certification Submit 2. Backflow Device Inspection 3. Plumbing Final INFORMATION FIELDS **APPLICANT NAME (Individual)Mark McGaughy **APPLICANT PHONE NUMBER 214-339-9000 VALUATION 2935 TCEQ 1517 BROOKWOOD DR.pdf FEE TOTAL PAID DUE Plumbing Permit Fee {VALUE}$ 57.00 $ 57.00 $ 57.00 TOTALS $ 57.00 $ 57.00 $ 0.00 READ AND SIGN I HEREBY CERTIFY THAT THE FOREGOING IS CORRECT TO THE BEST OF MY KNOWLEDGE AND ALL WORK WILL BE PERFORMED ACCORDING TO THE DOCUMENTS APPROVED BY THE BUILDING DEPARTMENT AND IN COMPLIANCE WITH THE CITY OF GRAPEVINE CODES REGULATING CONSTRUCTION. IT IS UNDERSTOOD THAT THE ISSUANCE OF THIS PERMIT DOES NOT GRANT OR AUTHORIZE ANY VIOLATION OF ANY CODE OR ORDINANCE OF THE CITY OF GRAPEVINE. I FURTHER CERTIFY THAT ALL WORK THAT IS REQUIRED TO COMPLY WITH ANY FEDERAL, STATE, AND / OR LOCAL LAW REGARDING ENERGY CONSERVATION WILL BE PERFORMED IN ACCORDANCE WITH THOSE LAWS, AND THAT VERIFICATION OF ENERGY CODE COMPLIANCE SHALL BE SUBMITTED TO THE CITY UPON REQUEST. September 13, 2023 Signature Date City of Grapevine PO Box 95104 Grapevine, Texas 76099 817) 410-3166 Plumbing Permit {VALUE} Project # 23-002958 Project Description: Replaced Doublecheck device in yard Issued on: 09/13/2023 at 3:23 PM MYGOV.US 23-002958, 09/13/2023 at 3:23 PM Issued by: Connie Cook Page 1/2 The follmim! form must be compkted fore h mbl,, tosatd. A skned and dukd *dowl mkist besubmimd to!!�CJIYILHC��Ater bu orw.. NAME OF PWS: QLity of Grap q PWS ID#: 2200013 I_PWS MAILING ADDRESS: IPO Box 95104 Grape yi1ne, TX 76099 1 PWS CONTACT PERSON: I FADDRESS OF SERVICE'. ­_1jennifer Blake 1517 Brookwood Dr Grapevine, TX 76051 . ......... The backflow prevention assembly detailed below -has been tested and md"itn'tained as re . quired by commission regulations and is certified to be olvrating within acceptable Ixtrameters. TYPE OF BACKYLOW PREVENTION A$SEMBLY , il—PA—): RedPressure Princi -D) Type 110 - ------ F—Red'aced-► . ... .... uced Pressure Principle (RPBA) Double Check Valve (DCVA) El Double Check -Detector (DCVA-D) Type 110 Pressure Vacuum Breaker iiiVb) Spill -Resistant Pressure Vacuum Breaker (SVB) Manufacturer: Main:Watts By Jim: Size, —9 -a - 0 0 7 M 1 Q T Bypass: �atw. Bypass: Model Number: BPA Location: lFront yard near sidewalk Number: Main.587018 Bypass: TBPAServes: lirri 'ation 1 Reason fo-r- test; 5New 0 1 Existing 0 Replacement El Old Model/Serial#`� ? Is the assembly installed in accordance with manufacturer recommendations and/or local codes? 190 1 Yes 0 No Is -potable water supply (auxiliary)? the assembly installed on a non 1 Yes No Type 11 ;t PVB & SVB Check Valve psi Held at 1.8 psid Held at g_.O psi �j Opened at Held at it Held at M Closed Tight 0 Closed Tight 0 'psid Closed Tight 0 Did not open' E] Jpsid Leaked 0 Leaked 0 Did not open 0 Leaked �Did it fully open 0 Lea ked 171 (Yes El /No ED Repairs and Main: Materials Used** Bypass: 'at_ T estAfter ed Hlat i [Held psid Regal Closed Tight 0 Date.■ Time- 244 check: nnje� XVA oniv Differential pressure gauge used: Make/Model- NIftiis TG-5 ,.Remarks: Permit # 23-002932 J Company Name: & A Activ6­Sac -k-fF&W-- Licensed Tester Name (Printff,�): 'John Ansley Company Address: 1611 N lH 35E., Suite 4% LicensedTester Name (Signature): Carrollton, TX 75006 Company Phone #: 7-- PAT License tBP00061 piration Date: The above Is certified to be true at the time of testing. TEST RECORDS MUST BE KEPT FOR AT LEAST THREE YEARS [30 TAC §290-46(8)1 ** USE ONLY MANUFACTURER'S REPLACEMENT PARTS