HomeMy WebLinkAboutPLBG2024-000627 (3)ADDRESS
1200 William D Tate
Ave.
Grapevine, TX 76051
LEGAL
1towne Center Addition
#2 Blk 1 Lot 3r
S
PERMIT HOLDER
Ron Tierney
Tierney Plumbing
(817) 251-9292
COLLABORATORS
•Ron Tierney
Tierney Plumbing
(817) 251-9292
OWNERS
•Secchi Sons Lp
(972) 980-8231
TENANTS
•Three Barrels Beer
Garden Ferrari's Italian
Villa
INSPECTIONS 6
1. Plumbing Rough In
2. Plumbing Top Out
3. Plumbing P-Trap
4. TCEQ Backflow Certification Submit
5. Backflow Device Inspection
6. Plumbing Final
INFORMATION FIELDS
**APPLICANT NAME (Individual)Ron Tierney
**APPLICANT PHONE NUMBER 8172519292
VALUATION 5100
FEE TOTAL PAID DUE
Plumbing Permit Fee {VALUE}$ 72.90 $ 72.90 $ 72.90
TOTALS $ 72.90 $ 72.90 $ 0.00
READ AND SIGN
I HEREBY CERTIFY THAT THE FOREGOING IS CORRECT TO THE BEST OF
MY KNOWLEDGE AND ALL WORK WILL BE PERFORMED ACCORDING TO
THE DOCUMENTS APPROVED BY THE BUILDING DEPARTMENT AND IN
COMPLIANCE WITH THE CITY OF GRAPEVINE CODES REGULATING
CONSTRUCTION. IT IS UNDERSTOOD THAT THE ISSUANCE OF THIS PERMIT
DOES NOT GRANT OR AUTHORIZE ANY VIOLATION OF ANY CODE OR
ORDINANCE OF THE CITY OF GRAPEVINE.
I FURTHER CERTIFY THAT ALL WORK THAT IS REQUIRED TO COMPLY WITH
ANY FEDERAL, STATE, AND / OR LOCAL LAW REGARDING ENERGY
CONSERVATION WILL BE PERFORMED IN ACCORDANCE WITH THOSE
LAWS, AND THAT VERIFICATION OF ENERGY CODE COMPLIANCE SHALL BE
SUBMITTED TO THE CITY UPON REQUEST.
February 21, 2024
Signature Date
City of Grapevine
PO Box 95104
Grapevine, Texas 76099
817) 410-3166
Plumbing Permit {VALUE}
Project # 24-000627
Project Description: Install 1/2" RPZ under coffee maker,
install drain, and extend a 1" drain over to the floor drain. Run
new PEX pipe from ceiling to RPZ and insulate and strap
"Three Barrels Beer Garden / "Ferrari's Italian Villa
Issued on: 02/21/2024 at 4:57 PM
MYGOV.US 24-000627, 02/21/2024 at 4:57 PM Issued by: Connie Cook
Page 1/2
Texas Commission on Environmental Quality
BACKFLOW PREVENTION ASSEMBLY TESTA MAINTENANCE REPORT
The folinwing firm mug be eonjjejed fear each a$sewbly tweed, A signed and dated original must be submitted to the vublic water 90P)ier for recordkeeping *vumses�
NAMEOFPWs.
ditV of Urapevine
PWS ID : I 2200013
_P_WS MAILING ADDRESS: a V Brook
_1�50.1 _had
C6rr_
DVS CONTACT PERSON: L�#ckfloW ordinator
ADDRESS OF SERVICE: 1, Ferra&§ ltaliafly!lla/1290 William D Tate Ave
_
The back -flow prevention assembly detailed below has been tested and maintained as required by commission regulations
and is certified to be operating within accel)table oarameters.
TYPE 00 BACKFLOW 'PREVENTION ASSEMBLY (BPA):
Reduced Pressure Principle (RPBA) 0: Reduced Pressure Principle -Detector (RPRA-D) Type it
Double Check Valve (DCVA) E]!
Double Check -Detector (DCVA-D) Type 1110
Pressure Vacuum Breaker (PYB) Spill -Resistant Pressure Vacuum Breaker (SVB)
Manufacturer: Main:
ypass:!�
Size: ain: r a. s
Bypass:
[Model Number. main:
yp s:
A BPA Location:
Serial Number: Main: 91'3L_7� /L1 Bypass: 1 BPA Se
rves:
-------- — ------------
Reason fOrtest: New lExisting Eli
Replacement 0Old Model/Serial#j
Is the assembly installed in accordance with manufacturer reco� �endations and/or local codes?
Is the assembly installed on a non potable water supply (auxiliary)?
TEST RESULT
ype 11
Reduced Pressure Principle Assembly (RPBA7�[ Assembly
PASS,
DCVA
DCVA
FAIL 0
I 2.'1 eqk Check*-*
Initial Test
Dale
Held at 12!wWs Held at
,
Closed Tight Closed Tight
Time:
Leakedl Leaked
Repairs, and
Main:;
Materials
Yes 0 No
0 Yes WNo
Relief Valve Bypass Check Air Inlet
Check Valve
_7 Opened < ,Held at1_psid Openedad psid Hold at
psid Closed Tight Did not open Z3 psid
Did not Leaked Did it fully open Leaked
open U
(Yes
useall Bypass:'
Test After Held at. psid -,Held at i psid Opened at Held at psid Opened at psid Held at 1
Riiali Closed Tight psid
Closed Tight Closed psid
Date:
TE3
Time: Fight
check: numeric reading re aired for DCVeA� ly
DC
v
FD rential pressure gauge used, 'ea ro
M�iffe_
Potable: Non" -Potable: 01
0 1 Date te'
MalkefModel-, I Midwest 845 5 W I 11 305�31 sted for accuracyi 11-2-24
ke trk
PERMIT# 24-000627
Company Name:
,.01 Accuracy Backflow Lien
ensed Tester Name Brian Coxt/Type).
Company Address: Licensed Tester Name (Signature):
Po Box 6832 Mckinney, Tx 75071
Company Phone #: ' 972-699-7156 BPAT License# BPOO17066
License Expiration Date: 2-23-25
The above is certified to bet at the titne of testing.
TEST RECORDS MUST BE KEPT FOR AT LEAST THREE YEARS t30 TAC §290.46(B)l
** USE ONLY MANUFACTURER'S REPLACEMENT PARTS
TCEQ-20700 (Revision 04-04-2019) Page I of t