HomeMy WebLinkAboutPLBG2024-000627 (3)ADDRESS 1200 William D Tate Ave. Grapevine, TX 76051 LEGAL 1towne Center Addition #2 Blk 1 Lot 3r S PERMIT HOLDER Ron Tierney Tierney Plumbing (817) 251-9292 COLLABORATORS •Ron Tierney Tierney Plumbing (817) 251-9292 OWNERS •Secchi Sons Lp (972) 980-8231 TENANTS •Three Barrels Beer Garden Ferrari's Italian Villa INSPECTIONS 6 1. Plumbing Rough In 2. Plumbing Top Out 3. Plumbing P-Trap 4. TCEQ Backflow Certification Submit 5. Backflow Device Inspection 6. Plumbing Final INFORMATION FIELDS **APPLICANT NAME (Individual)Ron Tierney **APPLICANT PHONE NUMBER 8172519292 VALUATION 5100 FEE TOTAL PAID DUE Plumbing Permit Fee {VALUE}$ 72.90 $ 72.90 $ 72.90 TOTALS $ 72.90 $ 72.90 $ 0.00 READ AND SIGN I HEREBY CERTIFY THAT THE FOREGOING IS CORRECT TO THE BEST OF MY KNOWLEDGE AND ALL WORK WILL BE PERFORMED ACCORDING TO THE DOCUMENTS APPROVED BY THE BUILDING DEPARTMENT AND IN COMPLIANCE WITH THE CITY OF GRAPEVINE CODES REGULATING CONSTRUCTION. IT IS UNDERSTOOD THAT THE ISSUANCE OF THIS PERMIT DOES NOT GRANT OR AUTHORIZE ANY VIOLATION OF ANY CODE OR ORDINANCE OF THE CITY OF GRAPEVINE. I FURTHER CERTIFY THAT ALL WORK THAT IS REQUIRED TO COMPLY WITH ANY FEDERAL, STATE, AND / OR LOCAL LAW REGARDING ENERGY CONSERVATION WILL BE PERFORMED IN ACCORDANCE WITH THOSE LAWS, AND THAT VERIFICATION OF ENERGY CODE COMPLIANCE SHALL BE SUBMITTED TO THE CITY UPON REQUEST. February 21, 2024 Signature Date City of Grapevine PO Box 95104 Grapevine, Texas 76099 817) 410-3166 Plumbing Permit {VALUE} Project # 24-000627 Project Description: Install 1/2" RPZ under coffee maker, install drain, and extend a 1" drain over to the floor drain. Run new PEX pipe from ceiling to RPZ and insulate and strap "Three Barrels Beer Garden / "Ferrari's Italian Villa Issued on: 02/21/2024 at 4:57 PM MYGOV.US 24-000627, 02/21/2024 at 4:57 PM Issued by: Connie Cook Page 1/2 Texas Commission on Environmental Quality BACKFLOW PREVENTION ASSEMBLY TESTA MAINTENANCE REPORT The folinwing firm mug be eonjjejed fear each a$sewbly tweed, A signed and dated original must be submitted to the vublic water 90P)ier for recordkeeping *vumses� NAMEOFPWs. ditV of Urapevine PWS ID : I 2200013 _P_WS MAILING ADDRESS: a V Brook _1�50.1 _had C6­rr­­­­_ DVS CONTACT PERSON: L�#ckfloW ordinator ADDRESS OF SERVICE: 1, Ferra&§ ltaliafly!lla/1290 William D Tate Ave _ The back -flow prevention assembly detailed below has been tested and maintained as required by commission regulations and is certified to be operating within accel)table oarameters. TYPE 00 BACKFLOW 'PREVENTION ASSEMBLY (BPA): Reduced Pressure Principle (RPBA) 0: Reduced Pressure Principle -Detector (RPRA-D) Type it Double Check Valve (DCVA) E]! Double Check -Detector (DCVA-D) Type 1110 Pressure Vacuum Breaker (PYB) Spill -Resistant Pressure Vacuum Breaker (SVB) Manufacturer: Main: ypass:!� Size: ain: r a. s Bypass: [Model Number. main: yp s: A BPA Location: Serial Number: Main: 91'3L_7� /L1 Bypass: 1 BPA Se rves: -------- — ------------ Reason fOrtest: New lExisting Eli Replacement 0Old Model/Serial#j Is the assembly installed in accordance with manufacturer reco� �endations and/or local codes? Is the assembly installed on a non potable water supply (auxiliary)? TEST RESULT ype 11 Reduced Pressure Principle Assembly (RPBA7�[ Assembly PASS, DCVA DCVA FAIL 0 I 2.'1 eqk Check*-* Initial Test Dale Held at 12!wWs Held at , Closed Tight Closed Tight Time: Leakedl Leaked Repairs, and Main:; Materials Yes 0 No 0 Yes WNo Relief Valve Bypass Check Air Inlet Check Valve _7 Opened < ,Held at1_psid Openedad psid Hold at psid Closed Tight Did not open Z3 psid Did not Leaked Did it fully open Leaked open U (Yes useall Bypass:' Test After Held at. psid -,Held at i psid Opened at Held at psid Opened at psid Held at 1 Riiali Closed Tight psid Closed Tight Closed psid Date: TE3 Time: Fight check: numeric reading re aired for DCVeA� ly DC v FD rential pressure gauge used, 'ea ro M�iffe_ Potable: Non" -Potable: 01 0 1 Date te' MalkefModel-, I Midwest 845 5 W I 11 305�31 sted for accuracyi 11-2-24 ke trk PERMIT# 24-000627 Company Name: ,.01 Accuracy Backflow Lien ensed Tester Name Brian Coxt/Type). Company Address: Licensed Tester Name (Signature): Po Box 6832 Mckinney, Tx 75071 Company Phone #: ' 972-699-7156 BPAT License# BPOO17066 License Expiration Date: 2-23-25 The above is certified to bet at the titne of testing. TEST RECORDS MUST BE KEPT FOR AT LEAST THREE YEARS t30 TAC §290.46(B)l ** USE ONLY MANUFACTURER'S REPLACEMENT PARTS TCEQ-20700 (Revision 04-04-2019) Page I of t