Loading...
HomeMy WebLinkAboutORD 2024-026ORDINANCE NO. 2024-026 AN ORDINANCE OF THE CITY COUNCIL OF THE CITY OF GRAPEVINE, TEXAS, ISSUING CONDITIONAL USE PERMIT CU24-07 TO AMEND THE PREVIOUSLY APPROVED SITE PLAN OF CU18-13 (ORDINANCE NO. 2018-043) FOR A PLANNED COMMERCIAL CENTER TO ALLOW FOR THE POSSESSION, STORAGE, RETAIL SALES AND OFF -PREMISE CONSUMPTION OF ALCOHOLIC BEVERAGES (BEER AND WINE ONLY), OUTSIDE DINING, GASOLINE SERVICE AND A MONUMENT SIGN IN CONJUNCTION WITH A CONVENIENCE STORE (RACETRAC), SPECIFICALLY TO REVISE THE SITE LAYOUT TO ADD FUELING PUMPS, FUELING CANOPIES, ELECTRIC VEHICLE CHARGING STATIONS, AND ASSOCIATED MANEUVERING LANES FOR BLOCK 1, LOT 1, RACETRAC GRAPEVINE ADDITION (3955 GRAPEVINE MILLS PARKWAY) IN A DISTRICT ZONED "CC", COMMUNITY COMMERCIAL DISTRICT ALL IN ACCORDANCE WITH A SITE PLAN APPROVED PURSUANT TO SECTION 47 OF ORDINANCE NO. 82-73 AND ALL OTHER CONDITIONS, RESTRICTIONS AND SAFEGUARDS IMPOSED HEREIN; CORRECTING THE OFFICIAL ZONING MAP; PRESERVING ALL OTHER PORTIONS OF THE ZONING ORDINANCE; PROVIDING A CLAUSE RELATING TO SEVERABILITY; DETERMINING THAT THE PUBLIC INTERESTS, MORALS AND GENERAL WELFARE DEMAND THE ISSUANCE OF THIS CONDITIONAL USE PERMIT; PROVIDING A PENALTY NOT TO EXCEED THE SUM OF TWO THOUSAND DOLLARS ($2,000.00); DECLARING AN EMERGENCY AND PROVIDING AN EFFECTIVE DATE WHEREAS, an application was made requesting issuance of a conditional use permit by making applications for same with the Planning and Zoning Commission of the City of Grapevine, Texas, as required by State statutes and the zoning ordinance of the City of Grapevine, Texas, and all the legal requirements, conditions and prerequisites having been complied with, the case having come before the City Council of the City of Grapevine, Texas, after all legal notices requirements, conditions and prerequisites having been complied with; and WHEREAS, the City Council of the City of Grapevine, Texas, at a public hearing called by the City Council did consider the following factors in making a determination as to whether this requested conditional use permit should be granted or denied.. safety of the motoring public and the pedestrians using the facilities in the area immediately surrounding the site; safety from fire hazards and measures for fire control; protection of adjacent property from flood or water damages, noise producing elements, and glare of the vehicular and stationary lights and effect of such lights on established character of the neighborhood; location, lighting, and types of signs and relation of signs to traffic control and adjacent property, street size and adequacy of width for traffic reasonably expected to be generated by the proposed use around the site and in the immediate neighborhood; adequacy of parking as determined by requirements of this ordinance for off-street parking facilities; location of ingress and egress points for parking and off-street locating spaces, and protection of public health by surfacing on all parking areas to control dust; effect on the promotion of health and the general welfare, effect on light and air; the effect on the overcrowding of the land, the effect on the concentration of population; the effect on the transportation, water, sewerage, schools, parks and other facilities; and WHEREAS, the City Council of the City of Grapevine, Texas, at a public hearing called by the City Council of the City of Grapevine, Texas, did consider the following factors in making a determination as to whether this requested conditional use permit should be granted or denied; effect on the congestion of the streets, the fire hazards, panics and other dangers possibly present in the securing of safety from same, the effect on the promotion of health and the general welfare, effect on adequate light and air, the effect on the overcrowding of the land, the effect on the concentration of population, the effect on the transportation, water, sewerage, schools, parks and other public facilities; and WHEREAS, all of the requirements of Section 48 of Ordinance No. 82-73 have been satisfied by the submission of evidence at a public hearing; and WHEREAS, the City Council further considered among other things the character of the existing zoning district and its peculiar suitability for particular uses and with the view to conserve the value of buildings and encourage the most appropriate use of land throughout this City; and WHEREAS, the City Council of the City of Grapevine, Texas, does find that there is a public necessity for the granting of this conditional use permit, that the public demands it, that the public interest clearly requires the amendment, that the zoning changes do not unreasonably invade the rights of those who bought or improved property with reference to the classification which existed at the time their original investment was made; and WHEREAS, the City Council of the City of Grapevine, Texas, does find that the conditional use permit lessens the congestion in the streets, helps secure safety from fire, panic and other dangers, prevents the overcrowding of land, avoids undue concentration of population, facilitates the adequate provisions of transportation, water, sewerage, schools, parks and other public requirements; and WHEREAS, the City Council of the City of Grapevine, Texas, has determined that there is a necessity and need for this conditional use permit and has also found and determined that there has been a change in the conditions of the property surrounding Ordinance No. 2024-026 2 CU24-07 and in close proximity to the property requested for a change since this property was originally classified and, therefore, feels that the issuance of this conditional use permit for the particular piece of property is needed, is called for, and is in the best interest of the public at large, the citizens of the City of Grapevine, Texas, and helps promote the general health, safety and welfare of this community. NOW, THEREFORE, BE IT ORDAINED BY THE CITY COUNCIL OF THE CITY OF GRAPEVINE, TEXAS: Section 1. That the City does hereby issue a conditional use permit in accordance with Section 48 of Ordinance No. 82-73, the Comprehensive Zoning Ordinance of the City of Grapevine, Texas, same being also known as Appendix "D" of the City Code, by granting Conditional Use Permit CU24-07 to amend the previously approved site plan of CU18-13 (Ordinance No. 2018-043) for a planned commercial center to allow for the possession, storage, retail sale and off -premise consumption of alcoholic beverages (beer and wine only), outside dining, gasoline service and a monument sign, specifically to revise the site layout to add fueling pumps, fueling canopies, electric vehicle charging stations, and associated maneuvering lanes in conjunction with a convenience store (RaceTrac) in a district zoned "CC", Community Commercial District Regulations within the following described property: Block 1, Lot 1, RaceTrac Grapevine Addition (3955 Grapevine Mills Parkway) all in accordance with a site plan approved pursuant to Section 47 of Ordinance No. 82-73, attached hereto and made a part hereof as Exhibit "A", and all other conditions, restrictions, and safeguards imposed herein, including but not limited to the following: None. Section 2. The City Manager is hereby directed to amend the official zoning map of the City of Grapevine, Texas, to reflect the herein conditional use permit. Section 3. That in all other respects the use of the tract or tracts of land herein above described shall be subject to all the applicable regulations contained in said City of Grapevine zoning ordinance and all other applicable and pertinent ordinances of the City of Grapevine, Texas. Section 4. That the zoning regulations and districts as herein established have been made in accordance with the comprehensive plan for the purpose of promoting health, safety, morals and the general welfare of the community. They have been designed with respect to both present conditions and the conditions reasonably anticipated to exist in the foreseeable future; to lessen congestion in the streets; to secure safely from fire, panic, flood and other dangers; provide adequate light and air; to prevent overcrowding of land, to avoid undue concentration of population; facilitate the adequate provisions of transportation, water, sewerage, drainage and surface water, parks and other public requirements, and to make adequate provisions for the normal business, commercial needs and development of the community. They have been made with reasonable consideration, among other things, of the character of the district, and its peculiar suitability for the particular uses and with a view of conserving the value of buildings and encouraging the most appropriate use of land throughout the community. Ordinance No. 2024-026 3 CU24-07 Section 5. This ordinance shall be cumulative of all other ordinances of the City of Grapevine, Texas, affecting zoning and shall not repeal any of the provisions of said ordinances except in those instances where provisions of those ordinances which are in direct conflict with the provisions of this ordinance. Section 6. That the terms and provisions of this ordinance shall be deemed to be severable and that if the validity of the zoning affecting any portion of the tract or tracts of land described herein shall be declared to be invalid, the same shall not affect the validity of the zoning of the balance of the tract or tracts of land described herein. Section 7. Any person violating any of the provisions of this ordinance shall be deemed guilty of a misdemeanor and upon conviction thereof shall be fined in a sum not to exceed Two Thousand Dollars ($2,000.00) and a separate offense shall be deemed committed upon each day during or on which a violation occurs or continues. Section 8. The fact that the present ordinances and regulations of the City of Grapevine, Texas, are inadequate to properly safeguard the health, safety, morals, peace and general welfare of the inhabitants of the City of Grapevine, Texas, creates an emergency for the immediate preservation of the public business, property, health, safety and general welfare of the public which requires that this ordinance shall become effective from and after the date of its final passage, and it is accordingly so ordained. PASSED AND APPROVED BY THE CITY COUNCIL OF THE CITY OF GRAPEVINE, TEXAS on this the 19th day of March, 2024. APPROVED: William D. Tate Mayor ATTEST: C,RAPF Tara Brooks City SecretaryL, , C9 APPROVED AS TO FORM: T% (7). Matthew C.G. Boyle City Attorney Ordinance No. 2024-026 4 CU24-07 T.O. SLAB 0' -0" T.O. PARAPET WALL 19' -10" T.O. TOWER ROOF 23' -0" T.O. SIDE TOWER ROOF 21' -6 1/2" 1 2 2.3 2.5 3 4 5 6 7dc 3 A420 1 A410 3 A411 2 A420 2 A411 1 A420 2 A410 BR -1 BR -1 BR -1 EF -1 EF -2 EF -1 EF -1 M-1 AW -1 AW -1 M-3 M-1 M-5 M-5 BR -1 M-1 M-5 M-5 M-3 C EF -1 EF -1 M-5 M-5 A3 DD A2 A1 A126 4 BR -1 BR -1 CS -1 BR -1 M-3 1 EP -1 AW -1 BR -1 M-3 BR -1 BR -1 BR -1 BRACKET 7'-8" T.O. 3 44 5 6 7 8 8 8 9 1010 13 15 EF -1 HP -1 M-5 M-1 BR -1 BR -1 1 2 13 1 E.J.E.J. 3 GL -1 GL -2 GL -1 13 A201 T.O. SLAB 0' -0" T.O. PARAPET WALL 19' -10" T.O. TOWER ROOF 23' -0" T.O. SIDE TOWER ROOF 21' -6 1/2" 122.32.534567d c 1 A421 2 A4213 A421 4 A421 BR -1 M-1 M-5 M-5 BR -1 BR -1 M-1 EF -1 EF -2 EF -1 EF -1 AW -1 EP -1 4'-0" 15'-5"4'-0"38'-5 1/2"4'-0"38'-3" 8'-0" A200 3 M-1 M-5 M-5 BR -1 M-5 BRACKET 7'-8" T.O. 1 56 8 8 1112 13 16 17 1714 9 3 412 E.J.E.J.E.J.E.J. 8'-10"54'-10 1/2"36'-5" 3 SOLDIER COURSE TO BE FLUSH WITH FACE OF WALL BEHIND GENERATOR TAP BOX, C/T AND METER 1 AW -1 EP -1 13'-0" 1818 T.O. SLAB 0' -0" T.O. PARAPET WALL 19' -10" T.O. TOWER ROOF 23' -0" T.O. SIDE TOWER ROOF 21' -6 1/2" B C baD.7DA.6A.3 4 A420 M-1 M-5 M-5 M-1 M-5 M-1 M-5 HP -1 BR -1 BR -1 BR -1 M-1 EF -2 EF -1 EF -1 EF -1 7 8 13 14 1 19'-4" 13'-0" A126 3 E.J.E.J. 3 T.O. SLAB 0' -0" T.O. PARAPET WALL 19' -10" T.O. TOWER ROOF 23' -0" T.O. SIDE TOWER ROOF 21' -6 1/2" BCb aD.7 D A.6 A.3 1 A422 1 A423 EF -1 M-1 M-5 M-5 M-1 EF -1 M-5 M-5 M-5 EF -2 EF -1 EF -1 M-1 BR -1 BR -1 BR -1 BR -1 M-1 M-5 M-5 M-3 EP -1 2 2 8 8 13 13 14 14 7 A201 2 B B E.J.E.J. 3 7 2 A423 GPD GROUP Professional Corporation AKRON, OH 44311 520 S. MAIN STREET, STE 2531 THESE PLANS ARE SUBJECT TO FEDERAL COPYRIGHT LAWS: ANY USE OF SAME WITHOUT THE EXPRESSED WRITTEN PERMISSION OF RACETRAC PETROLEUM, INC. IS PROHIBITED. 2016 RACETRAC PETROLEUM INC. COPYRIGHT NOTICE DESIGN PROFESSIONALS RaceTrac ISSUE/REVISION RECORD RACETRAC PETROLEUM, INC. 200 GALLERIA PARKWAY SOUTHEAST SUITE 900 ATLANTA, GEORGIA 30339 (770) 431 -7600 PROJECT NAME RaceTrac RACETRAC STORE NUMBER PROTOTYPE SERIES 5.5K 2.0 PLAN MODIFICATION NOTICE SPB NO.DATE STANDARD PLAN BULLETINS (SPB) MODIFY THE PROTOTYPE SERIES SET NOTED ABOVE. THE LISTED SPB REPRESENTS THE LATEST MODIFICATION INCORPORATED TO THIS PROTOTYPE SERIES SET AT ORIGINAL RELEASE. THE ISSUE/ REVISION RECORD COLUMN ABOVE LISTS ANY REVISIONS OR SPB INCORPORATED IN THIS SET AFTER THE ORIGINAL RELEASE. CONTACT RACETRAC ENGINEERING AND CONSTRUCTION FOR ANY SUBSEQUENT BULLETINS NOT INCORPORATED HEREIN. PROFESSIONAL SEAL PROJECT NUMBER SHEET TITLE SHEET NUMBER ® ® DATE DESCRIPTION A300 2016157.03 EXTERIOR ELEVATIONS 3955 GRAPEVINE MILLS PARKWAY TEXAS 76051 GRAPEVINE GRAPEVINE MILLS 2018 RH MO #1065 08/27/18 PERMIT SET ELEVATION KEYNOTES 1 WALL MOUNTED SECURITY CAMERA 2 3" SQUARE DOWNSPOUT. REFER TO CIVIL DRAWINGS FOR CONNECTIONS 3 MECHANICAL EQUIPMENT BEYOND 4 REFER TO DETAILS ON SHEET A431 FOR CAST STONE SHAPE 5 HOSE BIB; REFER TO PLUMBING DRAWINGS 6 PATIO FAN; REFER TO SPECIFICATIONS 7 ILLUMINATED SIGN PANEL BY OWNER MOUNTED ON RACEWAY. 8 ACM PANEL REVEAL LINE. REFER TO REFLECTED CEILING PLAN FOR DIMENSIONS 9 INTERCOM AND SPEAKER 10 EMERGENCY FUEL SHUT OFF SWITCH. MOUNT TOP OF SIGN AT 48" A.F.F. 11 LOCATION OF ELECTRICAL SERVICE C/T AND METER 12 GENERATOR TAP BOX - SEE ELECTRICAL FOR LOCATION 13 SECURITY CAMERA MOUNTED TO FASCIA 14 OVERFLOW SPILL SCUPPER 15 PACKAGE PASSER. REFER TO EQUIPMENT PLAN 16 PROVIDE METAL GUARD GATE AT LADDER TO 8'-0" A.F.F. WITH LOCKING HASP 17 4'-0" WIDE X 1'-7" HIGH SCUPPER. REFER TO DETAILS 9 & 10 ON SHEET A201 18 12" WIDE BY 4" HIGH SCUPPER. REFER TO DETAILS ON SHEET A201. GENERAL NOTES 1. CONTRACTOR SHALL VERIFY ALL EXTERIOR MATERIAL CO LOR AND FINISHES WITH THE ARCHITECT. ANY DISCREPANCIES NOTED SHALL BE BRO UGHT TO THE ATTENTION OF THE ARCHITECT FOR CLARIFICATION. 2. PROVIDE EXPANSION JOINTS (EJ) AT ALL LOCATIONS W HERE EIFS ABUTS A DISSIMILAR MATERIAL OR WHERE OTHERWISE REQUIRED BY MANUFACTURER. 3. PROVIDE EXPANSION JOINTS (EJ) AS LOCATED ON EXTE RIOR ELEVATION. SPECIFICATION FOR JOINT SEALANT SHALL BE 'PRECAST W HITE' SL-2 BY TREMCO. 4. MAXIMUM SPACING OF EXPANSION JOINTS SHALL BE 15'-0" O.C. OR PER MANUFACTURER RECOMMENDATION. 5. REFER TO LIGHTING PLANS FOR LIGHTING FIXTURE LOC ATION AND SCHEDULE. 6. REFER TO STRUCTURAL DRAWINGS FOR JOIST AND BEAM BEARING AND FOUNDATIONS. 7. REFER TO REFLECTED CEILING PLANS FOR COMPLETE DIMENSIONS OF ACM JOINT LOCATIONS. 3/16" = 1'-0"1 FRONT ELEVATION 3/16" = 1'-0"2 REAR ELEVATION 3/16" = 1'-0"3 LEFT ELEVATION 3/16" = 1'-0"4 RIGHT ELEVATION EXTERIOR MATERIAL SCHEDULE AWNING AW-1 - ALUMINUM AWNING SELECTED BY RACETRAC BRICK BR-1 BORAL LAREDO BRICK MORTAR COLOR "LIGHT BUFF" CAST STONE CS-1 CONTINENTAL CAST STONE OR APPROVED OTHER MATCH BORAL TUSCAN LINTEL CHAMPAGNE COLOR 1102 NATURAL STONE; MORTAR COLOR "LIGHT BUFF". SEAL WITH (SL-5) SEALANT. CEMENT BOARD HP-1 JAMES HARDIE ARTISAN V-GROOVE SIDING PAINT SHERWIN WILLIAMS SEALSKIN #7675 EIFS EF-1 STO STO THERM CI "FINE FINISH" APPLICATION; COLOR TO MATCH SW #6113 "INTERACTIVE CREAM" EF-2 STO STO THERM CI "FINE FINISH" APPLICATION; COLOR TO MATCH SW #6094 "SENSATIONAL SAND" GLAZING GL-1 1" NON-IMPACT RATED INSULATED GLAZING CLIMATE ZONES 2 OR 3. IGU AT STOREFRONT 0.28 U-FACTOR, SHGC PF>0.25=0.27 (1/4" PPG SOLARBAN 70-XL LOW-E #2 +1/2" AIR +1/4" CLEAR) OR APPROVED ALTERNATE GL-2 1" NON-IMPACT RATED ACID ETCHED INSULATED GLAZING CLIMATE ZONES 2 OR 3. IGU AT STOREFRONT 0.28 U-FACTOR, SHGC PF>0.25=0.27 (1/4" PPG SOLARBAN 70-XL LOW-E #2 +1/2" AIR +1/4" CLEAR SATIN ETCH #3) OR APPROVED ALTERNATE METAL M-1 PREFINISHED 4" 2-PIECE COMPRESSION METAL COVER METAL TO MATCH STOREFRONT COLOR DARK BRONZE M-2 COLOR DARK BRONZE. METAL TO MATCH STOREFRONT COLOR DARK BRONZE M-3 VISTAWALL (OR APPROVED ALTERNATE) FG-3000 STOREFRONT SYSTEM (OR APPROVED ALTERNATE) PREFINISHED DARK BRONZE ANODIZED ALUMINUM AA-MI2C22A44 M-5 ALCOA REYNOBOND PE COLORWELD 500 "CLASSIC BRONZE" M-7 VERSATEX WP4 TONGUE AND GROOVE PAINT INTERACTIVE CREAM PAINT EP-1 SHERWIN WILLIAMS EXTERIOR PAINT TO SW #7020 "BLACK FOX" ROOFING DURO DUROLAST 50 MIL MEMBRANE ROOFING SYSTEM WHITE; MECHANICALLY FASTENED TREX TX-1 SELECT COMPOSITE 1/2" THICKNESS WOODLAND BROWN WINDOW FILM WF-1 WINDOW FILM; 3M PRESTIGE 70 SOLAR FILM WF-2 WINDOW FILM; OPAQUE THESE PLANS ARE SUBJECT TO FEDERAL COPYRIGHT LAWS: ANY USE OF SAME WITHOUT THE EXPRESSED WRITTEN PERMISSION OF RACETRAC PETROLEUM, INC. IS PROHIBITED. 2023 RACETRAC INC. COPYRIGHT NOTICE DESIGN PROFESSIONALS RaceTrac® Hill Foley Rossi & Associates ARCHITECTURE + ENGINEERING 3680 Pleasant Hill Road Suite 200 Duluth, GA 30096 770.662.9858 GTP CONSULTING ENGINEERS 4197 PLEASNT HILL RD SUITE 200 DULUTH, GA 30096 770.622.2270 ISSUE/REVISION RECORD DATE DESCRIPTION 2023.04.27 PRELIMINARY SUBMITTAL 2024.01.31 PERMIT COMMENTS 2024.02.19 PERMIT COMMENTS 2024.03.08 PERMIT COMMENTS PROJECT NUMBER 15.720 2024.03.08 RE D BL U E BL U E WH I T E 4' - 0 " 16 ' - 0 " ALL CANOPY LIGHTING SHALL BE RECESSED TO REDUCE GLARE RE D BL U E BL U E WH I T E BR-1 BR-1 BR-1 4' - 0 " 16 ' - 0 " RE D BL U E BL U E WH I T E BR-1 RE D WH I T E BL U E BL U E BR-1 BR-1 STANDARD CANOPY FASCIA COLOR SPECIFICATION CHART COLOR CALLOUT CANOPY MANUFACTURER STANDARD COLOR SPECIFICATION "TAN" LANE CANOPIES ETT TAN FASCIA McGEE CANOPIES ETT TAN FASCIA MADISON CANOPIES PUEBLO TAN FASCIA "RED" LANE CANOPIES TRD RED FASCIA McGEE CANOPIES TRD RED FASCIA - PROGRAM RED MADISON CANOPIES PROGRAM RED FASCIA C3001C3002 C300 3 C300 4 MATERIAL % OF ELEVATION STONE EIFS 0% 0% GLAZING METAL WOOD 0% 75% 0% REAR ELEVATION 329 TOTAL SF SQ. FOOT. BRICK 25% 0 0 0 248 0 81 MATERIAL % OF ELEVATION STONE EIFS 0% 0% GLAZING METAL WOOD 0% 75% 0% FRONT ELEVATION 329 TOTAL SF SQ. FOOT. BRICK 25% 0 0 0 248 0 81 MATERIAL % OF ELEVATION STONE EIFS 0% 0% GLAZING METAL WOOD 0% 50% 0% SIDE ELEVATION 161 TOTAL SF SQ. FOOT. BRICK 50% 0 0 0 80 0 81 MATERIAL % OF ELEVATION STONE EIFS 0% 0% GLAZING METAL WOOD 0% 50% 0% SIDE ELEVATION 161 TOTAL SF SQ. FOOT. BRICK 50% 0 0 0 80 0 81 THESE PLANS ARE SUBJECT TO FEDERAL COPYRIGHT LAWS: ANY USE OF SAME WITHOUT THE EXPRESSED WRITTEN PERMISSION OF RACETRAC PETROLEUM, INC. IS PROHIBITED. 2023 RACETRAC INC. COPYRIGHT NOTICE DESIGN PROFESSIONALS RaceTrac RACETRAC PETROLEUM, INC. 200 GALLERIA PARKWAY SOUTHEAST SUITE 900 ATLANTA, GEORGIA 30339 (770) 431-7600 PROJECT NAME RaceTrac RACETRAC STORE NUMBER PROTOTYPE SERIES 5.5K 2.0 PLAN MODIFICATION NOTICE SPB NO.DATE STANDARD PLAN BULLETINS (SPB) MODIFY THE PROTOTYPE SERIES SET NOTED ABOVE. THE LISTED SPB REPRESENTS THE LATEST MODIFICATION INCORPORATED TO THIS PROTOTYPE SERIES SET AT ORIGINAL RELEASE. THE ISSUE/ REVISION RECORD COLUMN ABOVE LISTS ANY REVISIONS OR SPB INCORPORATED IN THIS SET AFTER THE ORIGINAL RELEASE. CONTACT RACETRAC ENGINEERING AND CONSTRUCTION FOR ANY SUBSEQUENT BULLETINS NOT INCORPORATED HEREIN. PROFESSIONAL SEAL PROJECT NUMBER SHEET TITLE SHEET NUMBER ® ® Hill Foley Rossi & Associates ARCHITECTURE + ENGINEERING 3680 Pleasant Hill Road Suite 200 Duluth, GA 30096 770.662.9858 GTP CONSULTING ENGINEERS 4197 PLEASNT HILL RD SUITE 200 DULUTH, GA 30096 770.622.2270 C300 15.720 EV CHARGING CANOPY ELEVATIONS 3955 GRAPEVINE MILLS PKWY GRAPEVINE, TX 76051 TEXAS GRAPEVINE MILLS EDO 0203 08/19/22 2022 RH MO 0203 #1065 2024.03.08 PRELIMINARY SUBMISSION 1/8" = 1'-0"1 PROPOSED CANOPY ELEVATION 1/8" = 1'-0"2 PROPOSED CANOPY ELEVATION 1/8" = 1'-0"3 PROPOSED CANOPY FRONT ELEVATION 1/8" = 1'-0"4 PROPOSED CANOPY REAR ELEVATION FUEL CANOPY FINISH SCHEDULE ID MANUF. MATERIAL COMMENTS BRICK BR-1 US BRICK LAREDO BRICK MORTAR COLOR "LIGHT BUFF" FASCIA BLUE - 2" BLUE STRIPE RED - REFER TO SPECIFICATION CHART ON SHEET C100 WHITE - 8" WHITE STRIPE PAINT EP-1 SHERWIN WILLIAMS EXTERIOR PAINT TO SW #7020 "BLACK FOX" 3/32" = 1'-0"6 PROPOSED EDO CANOPY PLAN ISSUE/REVISION RECORD DATE DESCRIPTION 2023.04.27 PRELIMINARY SUBMITTAL 2024.01.31 PERMIT COMMENTS 2024.02.19 PERMIT COMMENTS 2024.03.08 PERMIT COMMENTS 2018 RH MO 5c RT2360 Grapevine Mills EDO Additional Site Signage 3955 Grapevine Mills Pkwy. Grapevine, TX. Revision #Date Page # and Details 1 11.07.23 Updated site pan. Added D5 Sign. 2 02.13.24 Shifted D1 to other side of drive. Moved D1 and D2 inside property line. Added D6 Color Schedule GENERAL NOTE: ALL WORK SHALL BE IN COMPLIANCE WITH RECOGNIZED INDUSTRY STANDARDS, MANUFACTURER’S RECOMMENDATIONS AND ALLAPPLICABLE STATE AND LOCALCODES. NO SUBSTITUTIONS ALLOWED. C1 C2 C3 C5 C6 SUPPLIER(S)PART NUMBER(S) AKZO NOBEL MATTHEWS Akzo SIGN91780 Red* MP81489 R137186 LVS Semi-Gloss V1.1 Racetrac Red COLOR LOGO RED MA AKZO NOBEL TTHEWS MP83729 R143456 L Akzo Sign 10553 White* VS Semi Gloss V1.1 WhiteWHITE AKZO NOBEL MATTHEWS Dark Bronze 313E MP21286 R170760 Dark Bronze 313EDARK BRONZE AKZO NOBEL MATTHEWS 3M RACETRAC BLUE PRICER BLACK 3630-22 Black Translucent Vinyl C7 C8 3M 3630-156 Vivid Green Translucent VinylPRICER GREEN 3M 3630-143 Poppy Red Translucent VinylPRICER RED C11 AKZO NOBEL FORT MYERS, FL AWNING ONLY MATTHEWS PMS 1807C Color Match (see provided sample) PMS 1807C Color Match (see provided sample) C15 AKZO NOBEL NAPLES, FL AWNING ONLY MATTHEWS SW 6444 Color Match (see provided sample) SW 6444 Color Match (see provided sample) C18 3MADDRESS WHITE 7725-10 White Opaque Vinyl R A CE T R A C PRINT-Provided by Miratec Systems S W IR LW O RLD PRINT-Provided by Miratec Systems 3M Akzo Code Sign3243 Blue* MP02136 R143265 LVS Semi-Gloss V1.1 Sultan Blue 7725-17 Vivid Blue Opaque Vinyl Page 2 STANDARD AWNING RED Mp15024 RED DRAGON LVS SEMI GLOSS V1.1 AKZO NOBEL MATTHEWSC19 CUSTOM COLOR MATCH-SAMPLE PROVIDED C20 STANDARD AWNING BLUE CUSTOM COLOR MATCH-SAMPLE PROVIDED Mp10259 LVS SEMI GLOSS V1.1 AKZO NOBEL MATTHEWS C9 PRICER BLUE 3M 3630-127 Intense Blue Translucent Vinyl (Ethanol Free- DEF) 3M 3630-43 Light Tomato Red Translucent Vinyl Provided by Others; Install by Sign Vendor 3M 3630-015 Yellow Translucent Vinyl 3M 3630-22 Black Translucent Vinyl or Laminated Digital Print -Provided by Miratec Systems 3M 3630-167 Bright Blue Translucent Vinyl or Laminated Digital Print -Provided by Miratec Systems 3M 3630-337 Process Blue Translucent Vinyl or Laminated Digital Print -Provided by Miratec SystemsC21EFC WGYG BLUE Mp10147 IMPULSE SATIN FINISH MATTHEWS C22 EFC WGYG BEIGE Sw9087 SMOKEY BEIGESHERWIN WILLIAMS Flex Face Provided by Others; Install by Sign Vendor Provided by Others; Install by Sign Vendor C23 EFC STANDARD COLOR Sw7048 URBANE BRONZESHERWIN WILLIAMSC24 A F F T A F F T A F T T V T FF=479.00 24K - B20 DIESEL (EDO Canopy) 14K - B10010K - DEF F F DEF DEF FE T DEF FE T DEF FE T MAS T E R SATE L L I T E MAS T E R SATE L L I T E DEF FE T SAT E L L I T E MAST E R DEF FE T SAT E L L I T E MAS T E R 28.00' 10.00' TRUCKS O N L Y 45 . 1 1' 45.00' 21" DOT ROLLOVER CURB + SHOULDER EV#1 EV#2 EV#3 EV#4 45 . 0 0 ' 80.83' 75 . 0 0 ' 10 7 . 9 4 ' 75 . 0 0 ' 75 . 0 0 ' 13.00'13.00' 48.3 1 ' 13 . 5 0 ' 50.00'50.00' 74.38' 70 . 0 0 ' 97 . 1 1' 36 . 0 0 ' 36 . 0 0 ' EV EV 30.00'30.00'70 . 0 0 ' 30 . 0 0 ' 40 . 0 0 ' 41 PARKING STALLS INCREASE FROM 36 30 . 0 0 ' 50 . 0 0 ' 50 . 0 0 ' 40 . 0 0 ' 36.00' 30. 0 5 ' Page 3Site Plan D1D2 D3 D4A B A A B Sign Legend D1 D2 D3 D4 Directional Sign Directional Sign Directional Sign Directional Sign A D5 Directional Sign D5 A B D6 Directional Sign AD6 Removed from this request TUBE PAINTED C23 DIRECT BURIAL INSTALL GENERAL NOTE: ALL WORK SHALL BE IN COMPLIANCE WITH RECOGNIZED INDUSTRY STANDARDS, MANUFACTURER’S RECOMMENDATIONS AND ALL APPLICABLE STATE AND LOCAL CODES. NO SUBSTITUTIONS ALLOWED. Page 4Non Illuminated Directional Sign: D1-D6 STRUCT RECT. 6063 T52 3” x 3” x 0.1875 SAMPLE MESSAGING SINGLE SIDED SIGNS WILL NOT HAVE MESSAGING ON SECONDARY SIDE QUANTITY 6 26.67 S.F. Each 160.0 S.F. Total 0.125 ALUMINUM PAINTED C1 WITH REFLECTIVE WHITE VINYLTRUCKS ONLY AUTOS ONLY 3'-4" 8' - 0 " 6- 1 / 2 " Left End View Directional Pylon 4” 4” D1 GENERAL NOTE: ALL WORK SHALL BE IN COMPLIANCE WITH RECOGNIZED INDUSTRY STANDARDS, MANUFACTURER’S RECOMMENDATIONS AND ALLAPPLICABLE STATE AND LOCALCODES. NO SUBSTITUTIONS ALLOWED. Page 5 SIDE A TRUCK ENTRY AUTO ENTRY TRUCK ENTRY TRUCK FUEL AUTO ENTRY SIDE A SINGLE SIDED SIDE A SINGLE SIDED SIDE B SHARED E XIT AUTOS ONLY D2 D3 D3 Non Illuminated Directional Sign: D1-D6 QUANTITY 6 26.67 S.F. Each 160.0 S.F. Total AUTO ENTRY GENERAL NOTE: ALL WORK SHALL BE IN COMPLIANCE WITH RECOGNIZED INDUSTRY STANDARDS, MANUFACTURER’S RECOMMENDATIONS AND ALLAPPLICABLE STATE AND LOCALCODES. NO SUBSTITUTIONS ALLOWED. Page 6 SIDE A TRUCK FUEL AUTOS ONLY SIDE B SHARED E XIT AUTOS ONLY D4 D4 Non Illuminated Directional Sign: D1-D6 QUANTITY 6 26.67 S.F. Each 160.0 S.F. Total SIDE A AUTOS ONLY SIDE B SHARED E XIT AUTOS ONLY D5 D5 SIDE A SINGLE SIDED TRUCK ENTRY AUTOS ONLY D6 3' - 6 " 1'-5 1/4" OMITTED Site Plan GENERAL NOTE: ALL WORK SHALL BE IN COMPLIANCE WITH RECOGNIZED INDUSTRY STANDARDS, MANUFACTURER’S RECOMMENDATIONS AND ALLAPPLICABLE STATE AND LOCALCODES. NO SUBSTITUTIONS ALLOWED. Page 7 on Page 2See Color Schedule P2 P1 P3 PT1 PT2 PT3 Sign Legend P1 Parking SignP1 P2 P3 PT1 PT2 Parking / Towing Sign Parking / Towing Sign Parking Sign Parking Sign Parking Sign PT2 Parking / Towing Sign PT2 Parking / Towing SignPT3Parking / Towing Sign A F F T A F F T A F T T V T FF=479.00 24K - B20 DIESEL (EDO Canopy) 14K - B10010K - DEF F F DE F DE F FE T DEF FE T DEF FE T MA S T E R SAT E L L I T E MAS T E R SAT E L L I T E DE F FE T SA T E L L I T E MAS T E R DEF FE T SAT E L L I T E MA S T E R 28.00' 10.00' TRUCKS O N L Y 45 . 1 1' 45.00' 21" DOT ROLLOVER CURB + SHOULDER EV#1 EV#2 EV#3 EV#4 45 . 0 0 ' 80.83' 75 . 0 0 ' 10 7 . 9 4 ' 75 . 0 0 ' 75 . 0 0 ' 13.00'13.00' 48.3 1 ' 13 . 5 0 ' 50.00'50.00' 74.38' 70 . 0 0 ' 97 . 1 1' 36 . 0 0 ' 36 . 0 0 ' EV EV 30.00'30.00'70 . 0 0 ' 30 . 0 0 ' 40 . 0 0 ' 30 . 0 0 ' 50 . 0 0 ' 50 . 0 0 ' 40 . 0 0 ' 36.00' 30. 0 5 ' Parking Signs P1-P3 Page 8 QTY 3 DIRECT BURIAL GENERAL NOTE: ALL WORK SHALL BE IN COMPLIANCE WITH RECOGNIZED INDUSTRY STANDARDS, MANUFACTURER’S RECOMMENDATIONS AND ALL APPLICABLE STATE AND LOCALCODES. NO SUBSTITUTIONS ALLOWED. SINGLE FACED GROUND FRONT VIEW SIDE VIEW .090 ALUMINUM PANEL PAINTED RED C1 ON FRONT & BACK ORACAL 5500 ENGINEER GRADE REFLECTIVE WHITE VINYL 010 FIRST SURFACE APPLIED 2’-0” 1’ - 6 ” 3” x 3” x 144” ALUMINUM POLE PAINTED C3 8’ - 0 ” Parking / Tow Signs, PT1-PT3 GENERAL NOTE: ALL WORK SHALL BE IN COMPLIANCE WITH RECOGNIZED INDUSTRY STANDARDS, MANUFACTURER’S RECOMMENDATIONS AND ALL APPLICABLE STATE AND LOCALCODES. NO SUBSTITUTIONS ALLOWED. Page 9 QTY 3 .090 ALUMINUM PANEL PAINTED WHITE C2 ON REAR REFLECTIVE ENGINEER GRADE DIGITAL PRINT FIRST SURFACE APPLIED ZONE UNAUTHORIZED VEHICLES 24 HRS A DAY 7 DAYS TOW AWAY OR VESSELS WILL BE TOWED AWAY AT OWNER’S EXPENSE A WEEK SINGLE FACED Towing Company 000-000-0000 Ord. No. DIRECT BURIAL GROUND FRONT VIEW SIDE VIEW 3” x 3” x 144” ALUMINUM POLE PAINTED C3 8’ - 0 ” ZONE UNAUTHORIZED VEHICLES 24 HRS A DAY 7 DAYS TOW AWAY OR VESSELS WILL BE TOWED AWAY AT OWNER’S EXPENSE A WEEK 000-000-0000 TOWING COMPANY .090 ALUMINUM PANEL PAINTED RED C1 ON FRONT & BACK ORACAL 5500 ENGINEER GRADE REFLECTIVE WHITE VINYL 010 FIRST SURFACE APPLIED 2’-0” 1’ - 6 ” 12” 18 ” Ord. No.