HomeMy WebLinkAboutItem 06 - Temporary Concrete Batch Plant ITEM # - MEMO TO: HONORABLE MAYOR AND MEMBER S OF THE CITY COUNCIL FROM: ROGER NELSON, CITY MANAGER/$/ MEETING DATE: DECEMBER 5, 2000 SUBJECT: TEMPORARY CONCRETE BATCH PLANT FOR OSBURN CONTRACTORS RECOMMENDATION: City Council to consider approval of a request to locate a temporary concrete batch plant on Lot 1, Block 2, Westport Business Park from December 5, 2000 through May 1, 2001. BACKGROUND: The applicant, Osburn Contractors, is requesting a temporary concrete batch plant to be located at Lot 1, Block 2, Westport Business Park. This is the site for Oakmont Industries. The applicant plans to operate the batch plant from 7:00 a.m. to 7:00 p.m. Monday through Friday until May 1, 2001. Staff recommends approval. HTH/sh oAsh\osburn.cbp November 29,2000(11:02AM) CITY OF GRAPEVINE NOV 14 2000 TEMPORARY USE APPLICATION 77-1 1. APPLICANT �vl0V Q 2000 L NAME C�S✓�i/.c/ ADDRESS 9/ 7 _ CITYl.Z/ __`STATE -7 ZIP zSd 2 PHONE NO. ��� �- yZz FAX NO._ i97d 2. PROPERTY OWNER NAME ADDRESS 3 S Z a 3Gbs" CITY -�-4 a.�..i,„ STATE Co iAa- ZIP 3 n3 sad" PHONE NO. FAX NO. kt c� -Q�,5-q t 4 3. ADDRESS OF TEMPORARY USE PERMIT REQUEST: 4, LEGAL DESCRIPTIbN OF PROPERTY: �c7G 2 5. DESCRIBE REASON FOR TEMPORARY USE: 6. DATES OF PROPOSED TEMPORARY USE FROM—&.z?/4 � O CZ7_2,�do T. TOTAL NUMBER OF OFF-STREET OR HIGHWAY PARKING SPACES 8. TIME AND HOURS OF TEMPORARY USE OPERATION_7A-Aa- '7,1- SUBMIT A DETAILED DIAGRAM OF THE PROPOSED TEMPORARY USE,SITE/PLOT PLAN OR A PLAT SHOWING THE PROPOSED TEMPORARY USE DRAWN TO SCALE AND DIMENSIONED WITH OTHER DRAWINGS AS DESIRED OR AS REQUESTED BY STAFF. IN THE CASE OF CONCRETE MIXING OR BATCHING PLANTS FOR USE DURING THE CONSTRUCTION OF BUILDINGS OR PUBLIC IMPROVEMENTS FOR THIRTY (30) DAYS OR LESS MAY BE APPROVED BY THE DIRECTOR OF DEVELOPMENT SERVICES, CONCRETE MIXING OR BATCHING PLANTS FOR USE MORE THAN THIRTY DAYS SHALL REQUIRE APPROVAL BY COUNCIL. }(30 r OWNER NAME(PRINT))�ov.�p, s OWNER SIGNATURE NOT PUBLIC " (D DATE O CENSE EX �TIGiJ CITY OF GRAPEVINE, DEVELOPMENT SERVICES, P 0 BOX 95104. GRAPEVINE, TEXAS 76099 (817)410-3155 FAX (817 41 -} i 3012 4 TEXAS NATURAL RESOURCE CONSERVATION COMMISSION AIR QUALITY STANDARD PERMIT REGISTRATION for CONCRETE BATCH PLANTS FORM PI-IS-CBP Please print or type all information. This form is for use by Concrete Batch Plants ONLY. All other air quality standardpermit registrations should use Form PI-IS. Please contact the Mechanical/Combustion Section of the ro p (� Air Permits Division with any questions at(512) 239-1250 or Fax (512)239-1300. Written inquiries may be TNRCCaddressed to: Texas Natural Resource Conservation Commission, Office of Permitting, Remediation, & Registration,Air Permits Division le�ess6chec�s�oava�able on reque8 7,Austin �t,lto3as�ist7. �ne registrant provt'dingZthecrequ�ed ed to use an administrative comp information. ation to TNRCC,Air Permits Division(MC-162)P.O.Box 13087,Austin,TX Forward application and supporting document 78711-3087; Forward any fees and a copy of this form onl to Cashier,agency use O.Box 13088,Austin,TX 78711-3088. For age I. VERY IMPORTANT INFORMATION • YES ao O A. Is CONFIDENTIAL information part of this registration? YES If"YES",is each confidential page so marked in big red letters? B. Is this registration in response to,or related in any way to,a Notice of Violation(NOV)at t�25 If"YES" date of NOV: P ocatiQU21- and the specific TNRCC rules)violated: , C. Are the new facilities or changes to existing facilities represented in this registration requiredYtEoSep e as a disposal facility under the Taxes Solid Waste Disposal Act? D. Does this action result in the registration of any grandfathered facilities? YES 0 II, REGISTRANT INFORMATION A. PERMITTEE. Osburn Contractors Inc. ividual Authorized to Act for Registrant:Name: Title: Field Coordinator Texas State Comptroller's Tax ID No.: 7 5—2 4 6 9 0 6 2 Mailing Address: 1 7 C Fax: ( Q 7 2 9; d Telephone: ( 9 7 21 2 0 5 9 0 8 6 _,ayY Technical Contact and Designee for Public Notice Period Questions; Name. Ida- o, E-mail Address: IdaRodrz uez Mailing'Addess. 1917 Copper c'arla^� mY 7�n4� Tele hone: s urn on raRors.cam Fax: ( 1 Same B. TYPE OF FACILITY: Portable Read Mix • Permanent Specialty (check one): • Permanent(Central or Ready Mix} Y Name of Facility and Company's Facility No.: Osburn Plant #1 Job `name• WestnQr Buss. Par TNRCC Account ID No. (if known): ='9 3 - 2 81 8—O Previous Exemption,Permit-by-Rule or Permit No.: Length of Time at this Site: 6 monthY Proposed Start of Construction: C. PHYSICAL LOCATION OF FACILP1YY:— 1 Black 2 Westport Bossiness Park Street Address or Description of Location: Lot (A physical address or accurate driving directions must be provided on all registrations.) zip Code: 76051E County: Tarrant Nearest City: atitude and Lon 'tude must be to the nearest second Latitude: Lon 'lode: - III. PUBLIC NOTIFICATION INFORMATION Contiguous or adjacent to Public Works Project? YES NO Total number of employees of the company requesting this application: 300 lace a Please list the location(public place in the county where the facilities are/will be located)where you are planning to p copy of the application for public review and copying during the public comment period: Please furnish the names of the state legislators who represent the area where the facility site is located: State Senator: T .„„ ,,Toy Gon State Representative: Vicki Tri�i tt TNRCC F0RMP1--1 S--CBP,AIR QUALITY STANDARD PERMIT REGISTRATION FOR CONCRETE BATCH PLANT (Page 2 of 4) IV. FEE and FRANCHISE TAX TION: • A fee of$450 is attached. Ulicno NO If no,explain why: A permit fee is required if pue must be performed. Please forward the fee and a is form to: Cashier,TNRCC,P.O. Box 13088,Austin,TX 78711 • A copy of a Certificate of Good Standing from the State Comptroller's Office is attached.- YES • NO If no,explain why: If the permittee is a corporation, a certification is required. V. SUBNHT TIN FOLLOWING GENERAL INF TION: A. A current area map is attached. YES NO A current area map is required for all s dard ermit registrations. This map must show a true north arrow, the entire plantproperty,and the location of the operty relative to prominentgeographical features such as highways, roads, streams, and significant landmarks such as buildings, residences, and schools. All areas within one mile of any plant boundary must appear on this map. B. A plot plan is attached. YES NO A plot plan is required for all standard pe it re strations. The plotplan must show the plant property and clearly show all property lines, affected emission s, buildings, tanks,process vessels, and other process equipment. The plot plan must have a scale,must indicate a true north arrow, must reference a plant benchmark, and must be dated. C. A process description is attached. YE NO If NO, explain why: A process description and process flow 'agr m should be submitted for all registrations and must include a description of the project and related p esses, and a description of any equipment being installed. The description must be in sufficient detail to indicate that the facility will conform to the specified conditions of the standard permit. If alternative fencing or borders are proposed in lieu of distance setbacks for stockpiles and roads, these design specifics must be included. D. Submit the following_emissions data includin fugitive emissions and the basis of emissions estimates: Emission Name of Source Emission Rate of Each Air Contaminant Point lb/hr tons/yr Number Total Particulate Total LParticulate Suspended Matter Suspendeder Particulate < 10 microns Particulate crons P PM P 10) 7 Silo Cement 1 .94 2.52 .22 .28 10 Batch Drop Cement 1 .08 ' 1 . 40 TWRCC FORM PI-I,FCBP,AIR QUALITYSTANDARD PERMIT REGISTRATIONFOR CONCRETE BATCH PLANT (Page 3 of 4) VI. GENERAL REQUIREMENTS: Submit itemized information and/or analysis demonstrating that all applicable general requirements as specified in TNRCCRules ittach A17nformzzrten-c: ecessary to justify the following answers. Please note: Z ric dispersion modeling will not uired as part of the air quality impact analysis. 6.610(a)(1)- Not a lic • YES • NO • N/A§ 116.610(a)(2)- The construction or operation of the permitted sources will commence prior to the effective date of a revision of this standard permit under which the project would no longer meet the requirements for the standard permit N/A§ 116.610(a)(3)- The proposed project will comply with applicable provisions of federal New Source Performance Standards(NSPS) • YES • NO • N/A§ 116.610(a)(4)- The proposed project complies with applicable provisions of Federal Clean Air Act(FCAA)§ 112(Hazardous Air Pollutants)under Title 40 Code of Federal Regulations Part 61 (40 CFR Part 61). • YES • NO • N/A§ 116.610(a)(5)- The proposed project complies with applicable Maximum Achievable Control Technology(MACT)standards under FCAA 40 CFR Part 63. • YES • NO • N/A§ 116.610(b) - The proposed project does not constitute a new major source or major modification for Prevention of Significant Deterioration(PSD) or nonattainment permits • YES • NO • N/A§ 116.610(c) - The proposed project does not circumvent by artificial limitations the requirements of 30 TAC § 116.610 VII. A COPY OF THIS REGISTRATION and all attachments must be sent by the re 'sgi trant to A. Appropriate TNRCC Regional Office(City):_Arlington B. Local Programs: 1. City of Dallas Department of Health and Human Se?rvi es 2. • NO LOCAL PROGRAMS VIII. PROFESSIONAL ENGINEER SEAL: Is the estimated capital cost of this project greater than$2 million dollars? • YES • NO If YES, registration must be submitted under seal of a Texas Licensed Professional Engineer, unless exemption is claimed pursuant to the Texas Engineering Practice Act(TEPA). • Exemption from this P.E. seal requirement is claimed pursuant to TEPA Section DL I, (Name-Please print or type) (Title:Owner,Plant Manager,President, Vice President,Environmental Director, etc) state that I have knowledge of the facts herein set forth and that the same are true and correct to the best of my knowledge and belief. I fiuther state that to the best of my knowledge and belief,the project for which registration is made will not in any way violate any provision of the Texas Health& Safety Code (THSC),Chapter 382,Texas Clean Air Act,as amended, or any of the rules and regulations of the Texas Natural Resource Conservation Commission adopted under Chapter 382 or any local governmental ordinance or resolution pursuant to the Texas Clean Air Act. I further state that I have read and understand Section 382.091,THSC,which defines CRINIINAL OFFENSES for certain violations, including intentionally or knowingly making or causing to be made false material statements or representations in this registration, and Section 382.092,THSC,pertaining to rNAL PENALTIES. DATE: 10—12—0 0 SIGNATURE: NOTE- ORIGINAL SIGNATURE LN INK IS REQ UIRED. TABLE 20 CONCRETE HATCH PLANTS 1. What type of plant? (Check One) Permanent y Portable 2. What type of batching will be accomplished? (Check One) Wet (Rotary Mix Trucks) Dry Central Mix 3. Maximum Production Rates: d'/hour 7t,- pp yd'/year Maximum Operations: 1,9 hours/day _days/wk weeks/yr hour/year Does the facility operate at night? Yes No 4. Cement/Flyash/Additive Silo Information: i a) How many silos will this plant have? t b) What is the volume of each silo? 20,00 ft' ft' ft' c) Explain method of loading silo(s) : -Ij J d) Is each silo equipped ith overl ad war ing evic ? Yes No Please describe: i,j r i tt e) What type of abatement device will be used on silo vent( ) ? u c.-� — f) If baghouses are used on the vent(s) , for each device submit the following data and attach a Table 11: I.Flow rate cfm Total filtering area ft2 Air to cloth ratio Outlet grain loading gr dscf Method of cleaning bags Automatic (not manual) sequenced cleaning? Yes No II. Flow rate cfm Total filtering area ft2 Air to cloth ratio Outlet grain loading gr/dscf Method of cleaning bags Automatic (not manual) sequenced cleaning? Yes No III.Flow rate cfm Total filtering area ft2 Air to cloth ratio Outlet grain loading gr/dscf Method of cleaning bags Automatic (not manual) sequenced cleaning? Yes No 5. How will the batch drop to truck or central mixer be controlled to prevent dust emissions? Suction shroud with exhaust air to central baghouse? (complete following and (attach Table 11) Flow rate cfm Total filtering area n�CJ ft2 Air to cloth ratio Outlet rain loading gr/dscf Method of cleaning bags Air ViI tnrtn Automatic (not manual) sequenced cleaning? Yes No Flexible Discharge Spout with Water Fog Ring (attach design drawing) Other type of abatement device (explain in detail and attach design drawing) : 6. The cement weigh hopper will be vented tot he: (Pick One) Cement\Flyash Silo Baghouse _ Central Baghouse Discharge Spout Other: 7. List all additives or ad-mixtures and maximum usage rates at your facility: t1jal Pcs (2a Provide additional information on any items requested above in this space: 8. Will the sand and aggregate be washed prior to delivery at your facility? 4es No `9. The number of acres or square feet which may be covered by aggregate stockpiles:—:5i2� ! 10. Explain the metho of mov ng aggre to from storage piles to the mixing area (in detail) : f �.- W � r 11. Will water sprays be used at the fo lowing locations? a) Stockpiles Yes No b) Aggregate bin outlets Yes No c) Conveyor transfer points Yes No d) Screens Yes No 12. Plant roads will be: Paved & Cleaned Paved & Vacuumed oil Coated _ Gravel Chemical Sprayed Water Sprinkled 13. Aggregate transport trucks have: ___L Beds Covered by Tarps A sprinkler system 14. Please provide the following information for all vehicles which travel on plant property Weight (tons) No. of Distance Traveled Vehicle Type Speed Empty Full wheels per round trip (miles or feet)) Paved Unpaved Raw Aggregate 5 Loaders ��� Cement Tankers Flyash Tankers A)txx� Additives Mix Trucks 0, d 10/93 ■ r ( ( r a5• o: ' ° w. = .Ski ( 4` on if /. ®ry r o :use `^^•_%:� 17, 78 P ON.SITZ CiONCRtTV BATCH PLANT COMMGsUR.ATION s Dust Collector Sand Stockpile Cement Storage c o o, 300 ft CA m m — Rock Stockpile a . a Generator