HomeMy WebLinkAboutItem 24 & 25 - CU16-22; PD16-07 Renaissance Hotel TO: HONORABLE MAYOR, CITY COUNCIL MEMBERS AND THE
PLANNING AND ZONING COMMISSION
FROM: BRUNO RUMBELOW, CITY MANAGER.2)1
SCOTT WILLIAMS, DEVELOPMENT SERVICES DIRECTOR
MEETING DATE: OCTOBER 18, 2016
SUBJECT: DEVELOPMENT SERVICES TECHNICAL REPORT OF
CONDITIONAL USE APPLICATION CU16-22 AND PLANNED
DEVELOPMENT OVERLAY PD16-07 SILVER LAKE
CROSSINGS/RENAISSANCE HOTEL
1
I I t I
Grapevine ct APPLICANT: Mehul Patel
Lake
°eke
no
1X1635
r1
11111 ' I PROPERTY LOCATION AND SIZE:
`-"' ,1 as The subject property is located at 2225 Bass Pro
-' Court and is proposed to be platted as Lot 2, Block 1,
.Mo"e Silver Lake Crossings. The property contains
approximately 21.6 acres and has 475 feet of
1 — frontage along an internal access easement within
Glade Rd -' - — the planned commercial center.
REQUESTED CONDITIONAL USE, PLANNED DEVELOPMENT OVERLAY AND
COMMENTS:
The applicant is requesting a conditional use permit to establish a 300 room hotel
(Renaissance Hotel) with the possession, storage, retail sales, and on-premise
consumption of alcoholic beverages(beer,wine, and mixed beverages)in coniunction with
a restaurant, outdoor patio seating, outdoor speakers, and an increase in height. The
applicant is also seeking a planned development overlay to deviate from, but not be limited
to, reduction in the amount of parking provided below that required by ordinance.
With this request the applicant intends to develop a nine story, 300 room Renaissance
Hotel on the subject tract that is part of the planned commercial center established with the
Towneplace Suites/Marriott Courtyard/Hilton Garden Inn hotel complex located
immediately adjacent to the south. This hotel with have its access and frontage along a
0 2CU\CU16-22 42 1 October 12,2016(3 37PM)
shared common access easement through the planned commercial center. All guestrooms
will meet or exceed the minimum 380 s.f. room size requirement. The applicant will also be
providing 19,687 s.f. of conference space and a restaurant in excess of 4,000 s.f. with
seating for 150 patrons.A 2,934 s.f. swimming pool is also proposed, therefore meeting all
ordinance requirements for new hotel development within the City.
As part of the conditional use process,the applicant proposes to establish an outdoor patio
area with outdoor speakers that will be on a lower level from the main lobby looking
towards the lake to the northeast. Also, through the conditional use process, the applicant
is seeking to exceed the height maximum of 50 feet for the district to allow for the nine
story (114 feet) to be developed on the site.
Prior to the September 20 public hearing, as part of the applicant's initial submittal, a
planned development overlay was requested specifically to reduce the amount of parking
provided from a required 500 spaces to 280 spaces. This was based on a parking ratio of
0.8 spaces per room and 40 spaces for the restaurant function. A reduction was also
proposed for the tri-branded hotel immediately adjacent to the south from 717 spaces to
394 spaces which was similarly based on a ratio of 0.8 spaces per room and 42 spaces for
the restaurant function. Shortly before the meeting, the applicant reconsidered the amount
of parking being provided for both hotels and elected to increase the amount provided to
1 0 spaces per room as well and parking for the respective restaurant functions. In total,
the applicant obligated to provide 350 total parking spaces for the Renaissance Hotel and
492 total spaces for the tri-branded hotel to the south. This decision was made without
sufficient time to amend the site plan and provide elevations of a parking structure
necessary to contain this additional parking for use by both hotels.
The amended site plan now shows a four story parking garage located on the Renaissance
Hotel site positioned in the general location where the main surface parking area for the
Renaissance Hotel was originally located which represents the applicant's commitment to
provide one parking space per room plus parking necessary for the restaurant uses in both
hotels. This new structure will contain 284 parking spaces (approximately 70 per floor
level) that will be utilized by both hotels. For the Renaissance Hotel, 164 surface parking
spaces will be provided, and of the 284 spaces contained within the parking structure, 186
spaces will be utilized to meet the Renaissance Hotel's parking obligations. Although
approved at the September 20 meeting, the tn-branded hotel immediately adjacent to the
south (Townplace/Courtyard/Garden Inn) has remained as approved with 394 surface
parking spaces along with another 98 spaces within the parking structure for their use as
needed.
PRESENT ZONING AND USE:
The property is currently zoned "CC" Community Commercial District and undeveloped.
0 ZCU\CU16-22 42 2 October 12.2016(3 37PM)
HISTORY OF TRACT AND SURROUNDING AREA:
The subject and surrounding property was zoned"SP"Specific Use Permit Zoning and "I-1"
Light Industrial District prior to the 1984 City Rezoning. Portions of the subject property
were once part of the Austin Ranch which received approval from Council (Z77-18 and
Z81-44)for on-premise consumption of alcoholic beverages. At Council's September 21,
1999 meeting the subject and surrounding property (52.8 acres) was rezoned from "PID"
Planned Industrial Development District to "CC"Community Commercial District(Z99-13)
for a mixture of uses to include retail, hotel, and restaurant development. At the May 15,
2001 meeting Council approved a conditional use permit (CU01-22)for a restaurant with
on-premise alcohol beverages sales and consumption and outside dining however the
restaurant was never developed. At Council's August 1, 2009 meeting, a zone change
(Z09-04) rezoning 21.2 acres of the subject and surrounding properties from "CC"
Community Commercial District to "MXU" Mixed Use District along with three conditional
use requests (CU09-21, CU09-22, and CU09-23) to allow for three hotels, a multifamily
complex and a stand-alone parking garage was considered and later withdrawn by the
applicant. The following month at the September 15, 2009 meeting, Council approved a
conditional use request(CU09-32)to allow for a 300 room hotel with increased height and
on-premise alcohol beverage sales in conjunction with a restaurant and a pole sign; the
hotel was never developed. At the January 17, 2012 meeting, a conditional use request
was approved (CU11-34) for a six story, 300 room hotel (Marriott Courtyard and
TownePlace Suites) on the subject site. At a December 17, 2013 meeting the Council
approved a conditional use permit on the subject property to establish a planned
commercial center on the subject site and allow for a 20 foot pylon sign for the TownePlace
Suites/Marriott Courtyard hotel complex at the southeast corner of Bass Pro Court and
State Highway 26.
SURROUNDING ZONING AND EXISTING LAND USE:
NORTH: "CC" Community Commercial District, "HCO" Hotel and Corporate
Office District—undeveloped vacant property, D/FW Hilton Hotel
SOUTH: "GU" Governmental Use District—D/FW International Airport
EAST: "CC"Community Commercial District—undeveloped vacant property
WEST: "GU" Governmental Use District—Corps of Engineers/Grapevine
Lake, Cowboy's golf course
AIRPORT IMPACT:
The subject tract is located within "Zone C" Zone of Greatest Effect, as defined on the
"Aircraft Sound Exposure: Dallas/Fort Worth Regional Airport Environs" map. In"Zone C,"
industrial and commercial uses that can tolerate a high level of sound exposure are
acceptable. With appropriate sound attenuation for the project,the applicant's proposal is
01ZCIACU16-22 42 3 October 12,2016(3 37PM)
an appropriate use in these noise zones.
MASTER PLAN APPLICATION:
The Master Plan designates the subject property as a Commercial Land Use. The
applicant's proposal is in compliance with the Master Plan.
/rs
0 ZCU)CU16-22 42 4 October 12.2016(3 37PM)
. m .
. i� •
••
•
TM:®" to
....0
'el Ar y
a
2
//
\/ ) ..n.. - _- - : '"',3Bam.m 2127C
•
Oq.. •
... :::'
. s HCO - --
_ . . \` pF WgpeII SpN
,9
GU z. ' „„a
, rrI
- , II
–II .wc
•u
TR f
,o.,” _ .•Tt
�„ GPPpp
...............
i
. •i9S \ 103P lc70,2 0
m
Feet
0 200 400 600 800
�— CU16-22 & PD16-07
VW 4. Renaissance Hotel
Tin dale hat de nDate Prepared 9/12/2016 ..ed a at...,.i.iMe�..la .,,4o.,mw.e..w »b<.. a w,.,,..te.a
(Alto- aa.
GRA' VINE
-1 8 irA 5
CITY OF GRAPEVINE
CONDITIONAL USE APPLICATION
Form "A"
PART 1.APPLICANT INFORMATION
Name of applicant/agent/company/contact
Newcrest Image
Street address of applicant/agent
700 Slate Hwy 121 Byp,Suite 175
City/Slate/Zip Code of applicant/agent
Lewisville,TX 75067
Telephone number of applicant/agent Fax number of applicant/agent
214 744 4650 214 988 9006
Email address of applicant/agent Mobile phone number of applicant/agent
PART 2.PROPERTY INFORMATION
Street address of subject property
aaa5 sass Pro Col us- -k-
Legal description of subject properly(metes&bounds must be described on 8 112 It"sheet)
Lot 1 Block 1 Addition
Size of subject property
9 385 Acres Square footage
Present zoning classification Proposed use of the property
CC New Hotel
Circle yes or no,if applies to this application
Outdoor speakers No
Minimum/maximum distnct size for conditional use request
minimum 5 acres
Zoning ordinance provision requiring a conditional use
Section 25 Conditional Uses
PART 3.PROPERTY OWNER INFORMATION
Name of current properly owner
Supreme Bright Grapevine III LW I I I,
Street address of property owner JI �J
700 State Hwy 121 Byp,Suite 175
City/State/Zip Code of property owner 1.y
Lewisville,TX 75067
Telephone number of property owner Fax number of property owner.
214 988 9006
CUtk— aa
❑ Submit a letter describing the proposed conditional use and note the request on the site plan document
❑ In the same letter,describe or show on the site plan,and conditional requirements or conditions imposed upon the particular conditional
use by applicable district regulations(example buffer yards,distance between users)
❑ In the same letter,describe whether the proposed conditional use will,or will not cause substantial harm to the value,use,or enjoyment of
other property in the neighborhood Also,describe how the proposed conditional use will add to the value,use or enjoyment of other
property in the neighborhood
❑ Application of site plan approval(Section 47.see attached Form"B')
❑ The site plan submission shall meet the requirements of Section 47,Site Plan Requirements.
❑ All conditional use and conditional use applications are assumed to be complete when filed and will be placed on the agenda for public
heanng at the discretion of the staff Based on the size of the agenda,your application may be scheduled to a later date
❑ All public hearings will be opened and testimony given by applicants and interested citizenry Public hearings may be continued to the
next public hearing Public hearings will not be tabled
❑ Any changes to a site plan(no matter how minor or major)approved with a conditional use or conditional use permit can only be approved
by city council through the public hearing process
❑ I have read and understand all the requirements as set forth by the application for conditional use or conditional use permit and
acknowledge that all requirements of this application have been met at the time of submittal
PART 4.SIGNATURE TO AUTHORIZE CONDITIONAL USE REQUEST AND PLACE A CONDITIONAL USE
REQUEST SIGN ON THE SUBJECT PROPERTY
Akita l41a �rf
Print Applicants Name: Applicant's Signature:
The State of I4Xe
County Of D^ �(/��''II o / 5s ,� p .L.c
Before Me r LP (,( ttA on this day personally appeared DY GL*-L E ^� '
(n ry) (applicant)
known to me(or proved to me on the oath of card or other document)to be the person whose name is subscribed to the foregoing instrument and
acknowledged to me that he executed the same for purposes and consideration therein expressed
(Seal)Given under my hand and seal of office this 2r 12:day of ' '3 ,A D yo CC
KELSEY POLLARD
1I J p �
sr*A_ Notary State of texas I T
`f My Commission Expnes I Notary In And For to Or Texas
•,,,��," May 13. 2019
nituki1 ?A)44 C,-------------
Print Property Owners Name: Property Owner's Signature•
The State Of c).1/411A-144
''T ' ,L"�e
County Of y\�t�s�' �n 1,_—y e AA �.1 n
Before Me $tj 90 "`x✓_ on this day personally appeared M LkW /A-
(notary) (property owner)
known to me(or proved to me on the oath of card or other document)to be the person whose name is subscribed to the foregoing instrument and
acknowledged to me that he executed the same for the purrppooses and consideration therein expressed
(Seal)Given under my hand and seal of office this Zo"
uday of 't" 'j ,AD jo1C. .
4.. KELSEY POLLARD
Notary Public.State of Texas . ,i �",
' la My Commission Expires [—
Notary In And State Of texas R H r 1,, iii IL '1 II
'.:;;,,,,,0:F May 13, 2019 I I
By
Cu \ o- a
ACKNOWLEDGEMENT
All Conditional Use and Special Use Applications are assumed to be complete
when filed and will be placed on the agenda for public hearing at the discretion of
the staff. Based on the size of the agenda, your application may be scheduled to a
later date.
All public hearings will be opened and testimony given by applicants and
interested citizenry. Public hearings may be continued to the next public hearing.
Public hearings will not be tabled.
Any changes to a site plan (no matter how minor or major) approved with a
conditional use or a special use permit can only be approved by city council
through the public hearing process.
Any application for a change in zoning or for an amendment to the zoning
ordinance shall have, from the date of submittal, a period of four months to
request and be scheduled on an agenda before the Planning and Zoning
Commission and City Council If after said period of four months an application
has not been scheduled before the Commission and Council said application shall
be considered withdrawn, with forfeiture of all filing fees. The application, along
with the required filing fee may be resubmitted any time thereafter for
reconsideration. Delays in scheduling applications before the Planning and
Zoning Commission and City Council created by city staff shall not be considered
a part of the four month period.
I have read and understand all of the requirements as set forth by the application
for conditional use or special use permit and acknowledge that all requirements of
this application have been met at the time of submittal.
Signature of Applicant /1//3 -
Date: 9'17;I, 6
Signature of Owner I VV ---------
Date: .yi4 [ i7TiETU19iT)
,I+
I
/4-or/
S
GRAVINE
WA SI CITY OF GRAPEVINE
PLANNED DEVELOPMENT OVERLAY
APPLICATION
PART 1.APPLICANT INFORMATION
Name of applicant/agent/company/contact
Neworest Image
Street address of applicant/agent
700 Hwy 121 Byp,Suite 175
Gay/State/Zip Code of applicant/agent
Lewisville,TX 75067
Telephone number of applicant/agent Fax number of applrcant/agent
214 744 4650 214 988 9006
Email address of applicant/agent Mobile phone number of applicant/agent
Applicants interest in subject property.
Developer
PART 2. PROPERTY INFORMATION
Street address of subject property
aaas (Ms,s Pro Col, -r-E
Legal description of subject property(metes 8 bounds must be described on 8 1/21x 11"sheet)
Lot 1 Block 1 Addition
Size of subject property
9 385 Acres Square footage
Present zoning classification Proposed use of the property
CC New Hotel
Minimum/maximum distnct size for request
minimum 5 acres
Zoning ordinance provision requesting deviation from
off-street parking reduction
PART 3. PROPERTY OWNER INFORMATION
Name of current property owner.
Supreme Bright Grapevine Ill,LLC
Street address of property owner
700 Hwy 121 Byp,Suite 175
City/State/Zip Code of property owner
Lewisville,TX 75067
Telephone number of property owner Fax number of property owner.
214 744 4650 214 988 9006
r
P74'
O 1ZCLA1Formnapp pd doc 1'! L 11
7/17/2014 1 � I 2
BY-
b1b o�
❑ Submit a letter describing the proposed Planned Development and note the request on the site plan document
Cl Describe any special requirements or conditions that require deviation of the zoning distract regulations
❑ Describe whether the proposed overlay will,or will not cause substantial harm to the value,use or enjoyment of other property in
the neighborhood
❑ Describe how the proposed planned development will add to the value,use or enjoyment of other property in the neighborhood
❑ The site plan submission shall meet the requirements of Section 47, Site Plan Requirements
❑ All planned development overlay applications are assumed to be complete when filed and will be placed on the agenda for public
hearing at the discretion of the staff Based on the size of the agenda,your application may be scheduled to a later date
❑ All public hearings will be opened and testimony given by applicants and interested citizenry Public hearings may be continued to
the next public hearing Public hearings will not be tabled
❑ Any changes to a site plan(no matter how minor or major)approved with a planned development overlay can only be approved by
city council through the public hearing process
❑ I have read and understand all the requirements as set forth by the application for planned development overlay and acknowledge
that all requirements of this application have been met at the time of submittal.
PART 4.SIGNATURE TO AUTHORIZE PLANNED DEVELOPMENT OVERLAY REQUEST AND PLACE A PLANNED
DEVELOPMENT OVERLAY REQUEST SIGN ON THE SUBJECT PROPERTY
M 1 ai-A
Print Applicant's Name:�� p Applicant's Signature.
The State Of I tug
County Of Olw/'- l�� I
Before Me 4t'{ f� Fe(La(OA on this day personally appeared IV\Gtr Pc4-1-c4
(notary) (applicant)
known to me(or proved to me on the oath of card or other document)to be the person whose name is subscribed to the foregoing instrument and
acknowledged to me that he executed the same for the purposes and consideration therein expressed
(Seal)Given under my hand and seal of office this ZB day of T'01ly ,AO �(L
°• t't" KELSEY POLteRD JI/'
.I" NotaryELState of Texas
!,/1, ; My Commission Expires Notary In And For State Of Texas
Sat,;;,..... May 13, 2019
You L ) XL(
( n�✓v--
Print Property Owners Name: Property Owner's Signature:
The State Of r'b''K,C
CountyOf Dd1�/'���. �E J
Before Me I�l tOl( / `id on this day personally appeared e Lett E,/°✓��.r"(
in,J/
otary) (property owner)
known to me(or proved to me on the oath of card or other document)to be the person whose name is subscribed to the foregoing instrument and
acknowledged to me that he executed the same for the purposes and consideration therein expressed.
(Seal)Given under my hand and seal of office this heO day of J V�`rL ,A O �.
&n, KELSEY POLLARD J fi —
�,▪ sq Notary Public State of texas
e°o.▪ ('��e My Commission Expues Notary In And For eOf Texas
44,33, May 13, 2019
O'ZCLAI Forms'app pd doc 3
7/17/2e1 -fir- Il l\I It'I I
I t: ' III
II
KIL9 -off
ACKNOWLEDGEMENT
All Planned Development Overlay Applications are assumed to be complete when filed and
will be placed on the agenda for public hearing at the discretion of the staff. Based on the size
of the agenda, your application may be scheduled to a later data
All public hearings will be opened and testimony given by applicants and interested citizenry.
Public hearings may be continued to the next public hearing. Public hearings will not be
tabled.
Any changes to a site plan (no matter how minor or major) approved with a planned
development overlay can only be approved by city council through the public hearing
process.
Any application for a change in zoning or for an amendment to the zoning ordinance shall
have, from the date of submittal, a period of four months to request and be scheduled on an
agenda before the Planning and Zoning Commission and City Council. If after said period of
four months an application has not been scheduled before the Commission and Council said
application shall be considered withdrawn, with forfeiture of all filing fees. The application,
along with the required filing fee may be resubmitted any time thereafter for reconsideration.
Delays in scheduling applications before the Planning and Zoning Commission and City
Council created by city staff shall not be considered a part of the four month period.
I have read and understand all of the requirements as set forth by the application for planned
development overlay and acknowledge that all requirements of this application have been met
at the time of submittal.
Signature of Applicant
Date: 7118'11c
Signature of Owner l�W `'•�
Date:
Ti ji
0=U0Forms\app pd doe I q
aI
Li
E -
CLUI (s -tea
CALLISONZTKL
,r P I in October 6,2016
P.
Grapevine City Council
200 S.Main Street
Grapevine,TX 76051
Subject:300 Key Hotel Parking Garage
To whom it may concern:
In order to achieve a 1:1 parking ratio for the properties at Silver Lake Crossings,a 4 story,
284 stall parking garage will be located on Lot 2, Block 1,situated south east of the
proposed 300 key Renaissance hotel. Working with the natural grading of the site,the
garage will be 3 levels on the south facade fronting Bass Pro Court and drop one level
towards the lake for a total of 4 levels on the north facade. The exterior design of the
garage will mimic the hotel with the use of framed stucco panels along the sloping ramps
and stair towers. In order to accommodate fresh air requirements,the panels will stagger
between solid and void spaces. Where straight slabs are used,cables are provided to
support landscaping to grow vertically up the garage. An elevator tower located along the
front facade facing Bass Pro Court can be used for potential wayfinding opportunities.
Kind regards, / '
j•--:.{:fr
Jim Suggs
Associate Vice President
Tr]
Fi
ll' icl (-016 Ii)
L
JULY 19, 2016
RENAISSANCE SILVER LAKE PARKING
STUDY
GRAPEVINE, TEXAS
f
/ r.
I ft IITT 10LL'LS
10 �RI
ealcYVERA - Texas Registered Engineering Firm F-761
+ooaoo
_t 500 W.7th Street,Suite 300
••��f0,�.•' Mall Unit 23
Fort Worth,TX 76102-4728
1 6116 Phone:(817)335-300D
Fax:(817)335-1025
■
Silver Lake Parking Study I- I l I I11 / C)L I/\PS
Grapevine,TX
Introduction
The objective of this study is to determine if the required parking space rate requirements for the
proposed Renaissance Silver Lake Hotel in Grapevine,Texas may be reduced from 1.5 parking spaces per
guest room.Currently,the City of Grapevine's Comprehensive Zoning Ordinance requires that hotels
with restaurants,clubs,or conference facilities between 25,001 and less than 100,000 square feet(SF)
of conference area require 1 5 parking spaces for each room plus one parking space per 100 square feet
of conference area.This technical memorandum aims to determine if a lower parking space per room
rate is feasible without adverse effects to hotel operations.
Methodology
The first step in conducting this parking study was to determine an existing hotel of similar size,usage,
and location where parking lot usage data may be collected. By collecting data at a similar hotel,an
estimate of the proposed hotel's parking lot usage may be obtained. After consideration of the
qualifying factors, it was determine that the Courtyard Dallas DFW Airport North/Grapevine and
Towneplace Suites at 2200 Bass Pro Court,Grapevine,Texas were best suited as Study Hotels.The
proposed hotel's location along with the location of the Study Hotels is shown in Exhibit 1.A detail of
the proposed and Study Hotels is shown in Exhibit 2.
Proposed
Hotel
G
Bass Pro
1 Court
t Lr!-
Bass Pm
r Drive snow.
Study Hotels
-Courtyard&Towneplace G113
® 0
Exhibit 1—Proposed Hotel and Study Hotels Location
1
1i
N.TS. (yy �� I i i
' '� 2 11 .P \\ \.\ I Ii
zd
+r i kx �1 f
0'‘?g ��� ° 9. r i
v• 48 , ✓ ��,• m o e \ �' ` \ ^F
ti _ ...
- °Existing @ S
Courtyard/Towneplace J /Y
` Hotels .
L. Proposed '•`�� r. . fel; -%i
Renaissance
, �%
P/
/ J
Hotel `\.
!.r
s nr.
„t, „,. , ,. 0 „ Ihut I.
I. III?
`\` - n; N
jr, '' j i
S
k te_ ------ -
a _--
_ F
HUITf-K)L!ARS Silverlake Traffic Impact Analysis Exhibit
1
L.. .o,
S[Sp2�22 Cr� Dn e 2
9155%,433919612 Proposed Hotel and Study Hotels Detail
FA No.27611
Silver Lake Parking Study I 1l fill ZOL f:APS
Grapevine,TX
The Courtyard Marriot and Towneplace Suites are physically connected hotels that share the same
parking lot.Combined,the Study Hotels have 300 guest rooms and 26,018 SF of meeting space.A guest
room, meeting space,and available parking space comparison for the proposed Renaissance and
Courtyard/Towneplace hotels is shown in Table 1.
Table 1—Study and Proposed Hotel Comparison
Hotel IS of Guestrooms Meeting Space(SF) Available Parking Spaces
Existing Courtyard/Towneplace 300 26018 498
Proposed Renaissance 300 26127 TBD
Table 1 shows that the proposed Renaissance hotel has the same amount of guestrooms and only 109
SF of meeting space more than the Study Hotels. Following the City of Grapevine's Ordinance for
required parking spaces and considering the number of guestrooms, meeting space square footage, and
available parking spaces for the Study Hotels,the parking space to guest room rate is 0.79.The
calculations for this rate is shown below.
— (Available ParkingSpaces /Meeting Space SF)
Parking Space —
(Meeting
SF /f1
Guestroom Number o f Guestrooms
498 — /26018 SFl
Parking Space 100 SF 1 _
Guestroom 300 — 0'79
Based on information provided in Parking Generation,4th Edition from the Institute of Transportation
Engineers, parking lot usage at hotels is typically at its highest during the late evening to early morning
hours.Taking this into account,it was determined that the ideal time to conduct the parking lot data
collection was from 4:00 AM to 4:30 AM.Also, it is expected that hotel occupancy during the summer
months(the time of year which this study was conducted)would be at its highest leading up to and
during the weekend.Thus,the parking lot data collection was scheduled from Thursday,June 30th to
Saturday,July 2n° between 4:00 and 4:30 AM. Data collection results are shown in Table 2.
3
Silver Lake Parking Study I It_ 1111701 !.' RS
Grapevine,TX
Table 2—Courtyard Marriot/Towneplace Suites Parking Lot Study Data
Handicap All Percent Occupied
Date Spaces Other Total Capacity Parking Spaces
Spaces /Guest Rooms
Available
Spaces - 9 489 498 - -
Thursday, 1 216 217 44%
Occupied 6/30/2016 0 72
Spaces Friday,7/1/16 2 183 185 37% 0.62
Saturday,7/2/16 5 196 201 40% 0.67
From Table 2, it is observed that the Study Hotels' parking lot did not exceeded 44%of capacity and
averaged 41%over the three observation days The rate of occupied spaces versus guest rooms
averaged 0.67.
In addition to data collection,the staff at the Study Hotels were consulted concerning hotel occupancy
and parking lot usage.The Dual General Manager at the Marriot Courtyard and Towneplace Suites,
Michelle Strong,was contacted for this information. Per the General Manager,the normal occupancy
for both hotels is between 80%and 84%with peak periods of the year experiencing over 90%
occupancy. During these normal and peak periods,the amount of parking spaces the two hotels share is
more than adequate to handle all parking demands Only during special events held at the hotel,such as
weddings or large conferences, has parking demand exceeded capacity. During these special events,
guests were directed to park at a spill over lot nearby and subsequently shuttled over to the hotel.This
typically only happens three to four times a year and is not a usual occurrence.She also noted that due
to their proximity to DFW Airport, many of their guests arrive from the Airport and utilize the hotel
shuttle.The Study Hotels operate three shuttles to and from the Airport 24-hours a day,seven days a
week, and circulate every half hour.
Another factor analyzed as part of the parking study was the use of transportation network companies
(TNCs) at DFW Airport and their acceptance as a transportation alternative to taxies or other car-for-hire
services TNCs include app-based companies such as Uber and Lyft. Based on data from the Airport,
TNCs have become a significant part of ground transportation at DFW.Since December of 2015,TNCs
have exceeded taxies as the car-for-hire most often used at the Airport.Ground transportation ride data
from June 2015 to January 2016 is shown in Figure 1
4
Silver Lake Parking Study [HI. I I17_OI_I\RS
Grapevine,TX
250,000 —
234,570
216,644
200,000 —
193,006
183,330 187,743
163,569 70,415
150,000 — 152,255 Taxicab
—6—Limousine
100,000 — TNCs
shared Ride
--Total Rides
50,000 —
I I I I I I I I
°cyh ,;S< p°�h Seg15 O`15 tJO by O¢15 la 1°
< G c
Figure 1—Ground Transportation Rides at DFW Airport
From Figure 1, it is observed that due to the increasing usage of TNCs at DFW Airport,the total amount
monthly ground transportations rides since August 2015 to January 2016 has increased by over 60,000.
Documented rides from TNCs at the Airport began in August 2015
Analysis Results
From the data collection performed at the Study Hotels, it is observed that its parking lot was under
capacity during the study period To further enforce this observation,the General Manager provided
that under normal and even peak hotel occupancy,the parking lot is able to accommodate guest's
vehicles adequately. In addition,the 24-hour airport shuttle from the Study Hotels provides guests with
transportation to and from the Airport;therefore,reducing the amount of parking spaces required at
the hotel.
Based on data from DFW Airport,it is observed that transportation network companies are not only
becoming an accepted alternative to other car-for-hire services like taxies, but are also increasing the
amount of travelers using car-for-hire services as a whole.The utilization of these services provides less
of a parking demand for hotels in the surrounding DFW Airport vicinity like the Study Hotels and
proposed Renaissance Hotel.
5
Silver Lake Parking Study Hl
Grapevine,TX
Recommendations and Conclusions
From the analysis performed in this study,the following recommendations are suggested to address the
reduction of the parking rate at the proposed Renaissance Hotel. Recommendations are as follows:
1. The proposed hotel is expected to receive a high number of guests arriving DFW Airport.The
implementation of a 24-hour shuttle system,similar to that used at the Courtyard
Marriot/Towneplace Suites,would serve a large number of guests and aide to minimize parking
demand.
2. During special events at the proposed Renaissance Hotel,where parking demand may exceed
available spaces,a nearby parking lot may be used as a spill over lot to accommodate guest
vehicles Shuttles may be utilized to bring guests to and from this auxiliary parking lot.This
system is currently in use at the Courtyard/Towneplace Hotels.
In conclusion,the proposed Renaissance hotel may utilize a parking space to guest room rate of 0.8
without adversely affecting hotel operations.
6
ORDINANCE NO.
AN ORDINANCE ISSUING A CONDITIONAL USE PERMIT IN
ACCORDANCE WITH SECTION 48 OF ORDINANCE
NO. 82-73, THE COMPREHENSIVE ZONING ORDINANCE
OF THE CITY OF GRAPEVINE, TEXAS, SAME BEING ALSO
KNOWN AS APPENDIX "D" OF THE CITY CODE, BY
GRANTING CONDITIONAL USE PERMIT CU16-22 TO
ESTABLISH A 300-ROOM HOTEL TO ALLOW FOR THE
POSSESSION, STORAGE, RETAIL SALE, AND ON-
PREMISE CONSUMPTION OF ALCOHOLIC BEVERAGES
(BEER, WINE, AND MIXED BEVERAGES) IN CONJUNCTION
WITH A RESTAURANT; OUTDOOR PATIO SEATING;
OUTDOOR SPEAKERS; AND AN INCREASE IN HEIGHT IN A
DISTRICT ZONED "CC" COMMUNITY COMMERCIAL
DISTRICT ALL IN ACCORDANCE WITH A SITE PLAN
APPROVED PURSUANT TO SECTION 47 OF ORDINANCE
NO. 82-73 AND ALL OTHER CONDITIONS, RESTRICTIONS
AND SAFEGUARDS IMPOSED HEREIN; CORRECTING THE
OFFICIAL ZONING MAP; PRESERVING ALL OTHER
PORTIONS OF THE ZONING ORDINANCE; PROVIDING A
CLAUSE RELATING TO SEVERABILITY; DETERMINING
THAT THE PUBLIC INTERESTS, MORALS AND GENERAL
WELFARE DEMAND THE ISSUANCE OF THIS
CONDITIONAL USE PERMIT; PROVIDING A PENALTY NOT
TO EXCEED THE SUM OF TWO THOUSAND DOLLARS
($2,000.00); DECLARING AN EMERGENCY AND
PROVIDING AN EFFECTIVE DATE
WHEREAS, an application was made requesting issuance of a conditional use
permit by making applications for same with the Planning and Zoning Commission of the
City of Grapevine, Texas, as required by State statutes and the zoning ordinance of the
City of Grapevine, Texas, and all the legal requirements, conditions and prerequisites
having been complied with, the case having come before the City Council of the City of
Grapevine, Texas, after all legal notices requirements, conditions and prerequisites having
been complied with; and
WHEREAS, the City Council of the City of Grapevine, Texas, at a public hearing
called by the City Council did consider the following factors in making a determination as
to whether this requested conditional use permit should be granted or denied: safety of the
motoring public and the pedestrians using the facilities in the area immediately
surrounding the site; safety from fire hazards and measures for fire control; protection of
adjacent property from flood or water damages, noise producing elements, and glare of the
vehicular and stationary lights and effect of such lights on established character of the
neighborhood; location, lighting, and types of signs and relation of signs to traffic control
and adjacent property, street size and adequacy of width for traffic reasonably expected to
be generated by the proposed use around the site and in the immediate neighborhood;
adequacy of parking as determined by requirements of this ordinance for off-street parking
facilities; location of ingress and egress points for parking and off-street locating spaces,
and protection of public health by surfacing on all parking areas to control dust; effect on
the promotion of health and the general welfare; effect on light and air; the effect on the
overcrowding of the land; the effect on the concentration of population; the effect on the
transportation, water, sewerage, schools, parks and other facilities; and
WHEREAS, the City Council of the City of Grapevine, Texas, at a public hearing
called by the City Council of the City of Grapevine, Texas, did consider the following
factors in making a determination as to whether this requested conditional use permit
should be granted or denied; effect on the congestion of the streets, the fire hazards,
panics and other dangers possibly present in the securing of safety from same, the effect
on the promotion of health and the general welfare, effect on adequate light and air, the
effect on the overcrowding of the land, the effect on the concentration of population, the
effect on the transportation, water, sewerage, schools, parks and other public facilities;
and
WHEREAS, all of the requirements of Section 48 of Ordinance No. 82-73 have been
satisfied by the submission of evidence at a public hearing; and
WHEREAS, the City Council further considered among otherthings the character of
the existing zoning district and its peculiar suitability for particular uses and with the view
to conserve the value of buildings and encourage the most appropriate use of land
throughout this City; and
WHEREAS, the City Council of the City of Grapevine, Texas, does find that there is
a public necessity for the granting of this conditional use permit, that the public demands it,
that the public interest clearly requires the amendment, that the zoning changes do not
unreasonably invade the rights of those who bought or improved propertywith reference to
the classification which existed at the time their original investment was made; and
WHEREAS, the City Council of the City of Grapevine, Texas, does find that the
conditional use permit lessens the congestion in the streets, helps secure safety from fire,
panic and other dangers, prevents the overcrowding of land, avoids undue concentration
of population, facilitates the adequate provisions of transportation, water, sewerage,
schools, parks and other public requirements; and
WHEREAS, the City Council of the City of Grapevine, Texas, has determined that
there is a necessity and need for this conditional use permit and has also found and
determined that there has been a change in the conditions of the property surrounding and
in close proximity to the property requested for a change since this property was originally
classified and, therefore, feels that the issuance of this conditional use permit for the
Ordinance No. 2
particular piece of property is needed, is called for, and is in the best interest of the public
at large, the citizens of the City of Grapevine, Texas, and helps promote the general
health, safety and welfare of this community.
NOW, THEREFORE, BE IT ORDAINED BY THE CITY COUNCIL OF THE CITY OF
GRAPEVINE, TEXAS:
Section 1 . That the City does hereby issue a conditional use permit in
accordance with Section 48 of Ordinance No. 82-73, the Comprehensive Zoning
Ordinance of the City of Grapevine, Texas, same being also known as Appendix"D"of the
City Code, by granting Conditional Use Permit No. CU 16-22 to establish a 300-room hotel
(Renaissance Hotel) to allow for the possession, storage, retail sale, and on-premise
consumption of alcoholic beverages (beer, wine, and mixed beverages) in conjunction with
a restaurant; outdoor patio seating; outdoor speakers; and an increase in height in a
district zoned "CC" Community Commercial District within the following described property:
Lot 2, Block 1 , Silver Lake Crossings Addition (2225 Bass Pro Court) all in accordance
with a site plan approved pursuant to Section 47 of Ordinance No. 82-73, attached hereto
and made a part hereof as Exhibit "A", and all other conditions, restrictions, and
safeguards imposed herein, including but not limited to the following: None.
Section 2. The City Manager is hereby directed to amend the official zoning map
of the City of Grapevine, Texas, to reflect the herein conditional use permit.
Section 3. That in all other respects the use of the tract or tracts of land herein
above described shall be subject to all the applicable regulations contained in said City of
Grapevine zoning ordinance and all other applicable and pertinent ordinances of the City
of Grapevine, Texas.
Section 4. That the zoning regulations and districts as herein established have
been made in accordance with the comprehensive plan for the purpose of promoting
health, safety, morals and the general welfare of the community. They have been
designed with respect to both present conditions and the conditions reasonably anticipated
to exist in the foreseeable future; to lessen congestion in the streets; to secure safely from
fire, panic, flood and other dangers; provide adequate light and air; to prevent
overcrowding of land, to avoid undue concentration of population; facilitate the adequate
provisions of transportation, water, sewerage, drainage and surface water, parks and other
public requirements, and to make adequate provisions for the normal business,
commercial needs and development of the community. They have been made with
reasonable consideration, among other things, of the character of the district, and its
peculiar suitability for the particular uses and with a view of conserving the value of
buildings and encouraging the most appropriate use of land throughout the community.
Section 5. This ordinance shall be cumulative of all other ordinances of the City
of Grapevine, Texas, affecting zoning and shall not repeal any of the provisions of said
Ordinance No. 3
ordinances except in those instances where provisions of those ordinances which are in
direct conflict with the provisions of this ordinance.
Section 6. That the terms and provisions of this ordinance shall be deemed to be
severable and that if the validity of the zoning affecting any portion of the tract or tracts of
land described herein shall be declared to be invalid, the same shall not affect the validity
of the zoning of the balance of the tract or tracts of land described herein.
Section 7. Any person violating any of the provisions of this ordinance shall be
deemed guilty of a misdemeanor and upon conviction thereof shall be fined in a sum not to
exceed Two Thousand Dollars ($2,000.00) and a separate offense shall be deemed
committed upon each day during or on which a violation occurs or continues.
Section 8. The fact that the present ordinances and regulations of the City of
Grapevine, Texas, are inadequate to properly safeguard the health, safety, morals, peace
and general welfare of the inhabitants of the City of Grapevine, Texas, creates an
emergency for the immediate preservation of the public business, property, health, safety
and general welfare of the public which requires that this ordinance shall become effective
from and after the date of its final passage, and it is accordingly so ordained.
PASSED AND APPROVED BY THE CITY COUNCIL OF THE CITY OF
GRAPEVINE, TEXAS on this the 18th day of October, 2016.
APPROVED:
William D. Tate
Mayor
ATTEST:
Tara Brooks
City Secretary
APPROVED AS TO FORM:
Ordinance No. 4
John F. Boyle, Jr.
City Attorney
Ordinance No. 5
ORDINANCE NO.
AN ORDINANCE ISSUING A PLANNED DEVELOPMENT
OVERLAY IN ACCORDANCE WITH SECTION 41 OF
ORDINANCE NO. 82-73, THE COMPREHENSIVE
ZONING ORDINANCE OF THE CITY OF GRAPEVINE,
TEXAS, SAME BEING ALSO KNOWN AS APPENDIX "D" OF
THE CITY CODE, BY GRANTING PLANNED DEVELOPMENT
OVERLAY PD16-07 TO DEVIATE FROM, BUT NOT BE
LIMITED TO REDUCTION IN THE AMOUNT OF PARKING
PROVIDED BELOW THAT REQUIRED BY ORDINANCE ALL
IN ACCORDANCE WITH A SITE PLAN APPROVED
PURSUANT TO SECTION 47 OF ORDINANCE NO. 82-73
AND ALL OTHER CONDITIONS, RESTRICTIONS AND
SAFEGUARDS IMPOSED HEREIN; CORRECTING THE
OFFICIAL ZONING MAP; PRESERVING ALL OTHER
PORTIONS OF THE ZONING ORDINANCE; PROVIDING A
CLAUSE RELATING TO SEVERABILITY; DETERMINING
THAT THE PUBLIC INTERESTS, MORALS AND GENERAL
WELFARE DEMAND THE ISSUANCE OF THIS PLANNED
DEVELOPMENT OVERLAY PERMIT; PROVIDING A
PENALTY NOT TO EXCEED THE SUM OF TWO THOUSAND
DOLLARS ($2,000.00); DECLARING AN EMERGENCY AND
PROVIDING AN EFFECTIVE DATE
WHEREAS, an application was made requesting issuance of a planned
development overlay by making applications for same with the Planning and Zoning
Commission of the City of Grapevine, Texas, as required by State statutes and the zoning
ordinance of the City of Grapevine, Texas, and all the legal requirements, conditions and
prerequisites having been complied with, the case having come before the City Council of
the City of Grapevine, Texas, after all legal notices requirements, conditions and
prerequisites having been complied with; and
WHEREAS, the City Council of the City of Grapevine, Texas, at a public hearing
called by the City Council did consider the following factors in making a determination as
to whether this requested planned development overlay should be granted or denied:
safety of the motoring public and the pedestrians using the facilities in the area
immediately surrounding the site; safety from fire hazards and measures for fire control;
protection of adjacent property from flood or water damages, noise producing elements,
and glare of the vehicular and stationary lights and effect of such lights on established
character of the neighborhood; location, lighting, and types of signs and relation of signs to
traffic control and adjacent property; street size and adequacy of width for traffic
reasonably expected to be generated by the proposed use around the site and in the
immediate neighborhood; adequacy of parking as determined by requirements of this
ordinance for off-street parking facilities; location of ingress and egress points for parking
and off-street locating spaces, and protection of public health by surfacing on all parking
areas to control dust; effect on the promotion of health and the general welfare; effect on
light and air; the effect on the overcrowding of the land; the effect on the concentration of
population; the effect on the transportation, water, sewerage, schools, parks and other
facilities; and
WHEREAS, the City Council of the City of Grapevine, Texas, at a public hearing
called by the City Council of the City of Grapevine, Texas, did consider the following
factors in making a determination as to whether this requested planned development
overlay should be granted or denied; effect on the congestion of the streets, the fire
hazards, panics and other dangers possibly present in the securing of safety from same,
the effect on the promotion of health and the general welfare, effect on adequate light and
air, the effect on the overcrowding of the land, the effect on the concentration of
population, the effect on the transportation, water, sewerage, schools, parks and other
public facilities; and
WHEREAS, all of the requirements of Section 41 of Ordinance No. 82-73 have been
satisfied by the submission of evidence at a public hearing; and
WHEREAS, the City Council further considered among otherthings the character of
the existing zoning district and its peculiar suitability for particular uses and with the view
to conserve the value of buildings and encourage the most appropriate use of land
throughout this City; and
WHEREAS, the City Council of the City of Grapevine, Texas, does find that there is
a public necessity for the granting of this planned development overlay, that the public
demands it, that the public interest clearly requires the amendment, that the zoning
changes do not unreasonably invade the rights of those who bought or improved property
with reference to the classification which existed at the time their original investment was
made-land
WHEREAS, the City Council of the City of Grapevine, Texas, does find that the
planned development overlay lessens the congestion in the streets, helps secure safety
from fire, panic and other dangers, prevents the overcrowding of land, avoids undue
concentration of population, facilitates the adequate provisions of transportation, water,
sewerage, schools, parks and other public requirements; and
WHEREAS, the City Council of the City of Grapevine, Texas, has determined that
there is a necessity and need for this planned development overlay and has also found
and determined that there has been a change in the conditions of the property surrounding
and in close proximity to the property requested for a change since this property was
originally classified and, therefore, feels that the issuance of this planned development
overlay for the particular piece of property is needed, is called for, and is in the best
Ordinance No. 2
interest of the public at large, the citizens of the City of Grapevine, Texas, and helps
promote the general health, safety and welfare of this community.
NOW, THEREFORE, BE IT ORDAINED BY THE CITY COUNCIL OF THE CITY OF
GRAPEVINE, TEXAS:
Section 1 . That the City does hereby issue a planned development overlay in
accordance with Section 41 of Ordinance No. 82-73, the Comprehensive Zoning
Ordinance of the City of Grapevine, Texas, same being also known as Appendix"D"of the
City Code, by granting Planned Development Overlay PD 16-07 to deviate from, but not be
limited to, reduction in the amount of parking provided below that required by ordinance
within the following described property: Lot 2, Block 1 , Silver Lake Crossings (2225 Bass
Pro Court) all in accordance with a site plan approved pursuant to Section 47 of Ordinance
No. 82-73, attached hereto and made a part hereof as Exhibit "A", and all other conditions,
restrictions, and safeguards imposed herein, including but not limited to the following:
None.
Section 2. The City Manager is hereby directed to amend the official zoning map
of the City of Grapevine, Texas, to reflect the herein planned development overlay.
Section 3. That in all other respects the use of the tract or tracts of land herein
above described shall be subject to all the applicable regulations contained in said City of
Grapevine zoning ordinance and all other applicable and pertinent ordinances of the City
of Grapevine, Texas.
Section 4. That the zoning regulations and districts as herein established have
been made in accordance with the comprehensive plan for the purpose of promoting
health, safety, morals and the general welfare of the community. They have been
designed with respect to both present conditions and the conditions reasonably anticipated
to exist in the foreseeable future; to lessen congestion in the streets; to secure safely from
fire, panic, flood and other dangers; provide adequate light and air; to prevent
overcrowding of land, to avoid undue concentration of population; facilitate the adequate
provisions of transportation, water, sewerage, drainage and surface water, parks and other
public requirements, and to make adequate provisions for the normal business,
commercial needs and development of the community. They have been made with
reasonable consideration, among other things, of the character of the district, and its
peculiar suitability for the particular uses and with a view of conserving the value of
buildings and encouraging the most appropriate use of land throughout the community.
Section 5. This ordinance shall be cumulative of all other ordinances of the City
of Grapevine, Texas, affecting zoning and shall not repeal any of the provisions of said
ordinances except in those instances where provisions of those ordinances which are in
direct conflict with the provisions of this ordinance.
Ordinance No. 3
Section 6. That the terms and provisions of this ordinance shall be deemed to be
severable and that if the validity of the zoning affecting any portion of the tract or tracts of
land described herein shall be declared to be invalid, the same shall not affect the validity
of the zoning of the balance of the tract or tracts of land described herein.
Section 7. Any person violating any of the provisions of this ordinance shall be
deemed guilty of a misdemeanor and upon conviction thereof shall be fined in a sum not to
exceed Two Thousand Dollars ($2,000.00) and a separate offense shall be deemed
committed upon each day during or on which a violation occurs or continues.
Section 8. The fact that the present ordinances and regulations of the City of
Grapevine, Texas, are inadequate to properly safeguard the health, safety, morals, peace
and general welfare of the inhabitants of the City of Grapevine, Texas, creates an
emergency for the immediate preservation of the public business, property, health, safety
and general welfare of the public which requires that this ordinance shall become effective
from and after the date of its final passage, and it is accordingly so ordained.
PASSED AND APPROVED BY THE CITY COUNCIL OF THE CITY OF
GRAPEVINE, TEXAS on this the 18th day of October, 2016.
APPROVED:
William D. Tate
Mayor
ATTEST:
Tara Brooks
City Secretary
APPROVED AS TO FORM:
Ordinance No. 4
John F. Boyle, Jr.
City Attorney
Ordinance No. 5
A
r
3-tLVER LAKE CROZ!OS
RAPEVINE,
® t2�
cn
T E X A S
1► Y
a
m
DEVELOPER / OWNER:
NEWCREST IMAGE
700 STATE HIGHWAY 121 BYPASS, SUITE 175
LEWISVILLE, TX 75067
PHONE: (214) 744-4650
FAX (214)988-9006
CONTACT: MEHUL PATEL
EMAIL: Mehul.Patel@Newcrestlmage.com
CUP
UBMITTAL
GRAPE , TE;V,54.
AUGUST 2016
VICINITY MAP
NTS
i
CRGSSI NGS
INGS
Sheet Number
Sheet Title
1
COVER
2
OVERALL SITE PLAN
3
OVERALL SITE DATA
4
OVERALL VARIANCE REQUESTS
5
SITE PLAN
6
LANDSCAPE PLAN
7
LEVEL 1 FLOOR PLAN
8
LEVELS 2-7 TYPICAL FLOOR PLAN
9
LEVEL 8 FLOOR PLAN
10
LEVEL B 1 FLOOR PLAN
LEVEL 1 LIGHTING AND OUTDOOR SPEAKER
I I
PLAN
LEVEL B1 LIGHTING AND OUTDOOR
12
SPEAKER PLAN
13
BUILDING ELEVATIONS
14
BUILDING ELEVATIONS
15
BUILDING ELEVATIONS
16
PARKING GARAGE ELEVATIONS
17
300- KEY HOTEL SIGNAGE DETAILS
CASE NAME: --R VHE CROSS NCS/REN455MJDf fWTE1
CASE NUMBER: -8-22. PDIO-
LOCATION. SILVER IAKSEPCR0951N COURT,RO IDR— UPT 2. LOCK i,
MAYOR SECRETARY
DATE:
PLANNING AND ZONING COMMISSION
CHAIRMAN
NOT FO CONSTRUCTION
CIVIL ENGINEER 1 SURVEYOR:
1R
P<E of rF+
y
�+..
HUI
i KIMBERLY ••
R.COLE /
Engineering/Architecture/Surveying
++�� 105298 •�¢��
0+I FS .�CEN......
500 W. 7th St. Ste. 300 Fort Worth, Texos 76102H.
,11\�t�A•Ei��' F•b
zUors, Inc.
Phone (817)335-3000 Fax (817)335-1025
R,g*,
Firm Registration .No.In F-781
CONTACT: KIMBERLY R. COLE, P.E.
CASE NAME: --R VHE CROSS NCS/REN455MJDf fWTE1
CASE NUMBER: -8-22. PDIO-
LOCATION. SILVER IAKSEPCR0951N COURT,RO IDR— UPT 2. LOCK i,
MAYOR SECRETARY
DATE:
PLANNING AND ZONING COMMISSION
CHAIRMAN
i
1
1
f
1
1
f �=
DOCK
1
OUS77NG LAKE /a
a
/f
Q
OWNER: DFW HILTON ADDITION _.
PUBLIC TRAIT.
CONNECTION
DOCK , �---
/
OWNER.,
EVERGREEN
V LLIANCE
ERGREE
GOLF
/ EKLSRNG ZONING CC DOCK
PROPOSED ZONING: PCC
SILVER AD i E ki k y k s t
c `
CROSSINGS AODIRON
LOT 2
BLOCK I PUBUC 1NM PAVILION
(zve AG) s7sTEM/_� k ty T"
Fr.)
MULR FAABLY ka '� PROPOSED
I � RESTDlD.71A7. I aft } y k CONNECTION TO
EX S NG ZONING CC
PD M1N' ~y- PUBLIC TRAIL
I ..', 'PROPoSED ZONING: F SYSTEM
THE BLUFFS Ar /
GRAPEVINE 3
LOT IAI `{ )`
BLOCK T
I1a.57 AC)
k Li� a `L (seI Teao SQ Fr) k
PAVKION
PROPOSED SIGN
MULTI -FAMILY
SAWARY
G4R{CE SEWER LIFT y
f
S7A710NTr�jFUTU
RESUE azncc PROPosEo sIoN lPccl
eamNc $
RLE BLUFFS AT
kT �.LOT IA2
ti GOLF CART PROPOSEDSYCN ❑ BIKE
BLOCK I
RENTALS + �Zt 4S3 AC
IRE?WSFW �NO7EL 2 b{ , (188,583.0 SC. FT.) Q`
m
off' \_ �'s5.:+"^� /PROPOSED TRAIL
u` � Exisrrvc zoNNc. acc - ���� � � � � '��' ♦� /
a PROPoSED ZONING' PCC �, I (� O mNE
SILVER LAKE I --f— � *� GR4PEW
CROSSINGS ADD 70N EXISTING SIGN (PCC) i�. \ PROPOSED SIGN PUBLIC IM
y f LOT IA NULD-FAM LY PUBLIC TRAL PROPOSED
CONNECDON 7TJ
W BLOCK rPUBLI( PROPOSED MUL SYSTE RLVL
o r
(8.88 _ sySTEM
(420,654.0 SQ.
'PROPOSED
H
SIGN (PCC)
9`
t il i tkA b„. 4 t
a - EXSRNG QUAL BRAND FUTURE SITE 998
r m (�
�"g''"� k'�' -TT— EX/STINO ZONNG: CC
THE BLUFFS AT
LCRAPEVINE
i o H2TON G4ROEN INN BLOCK 1 `7 0
❑ + t HOED Em NSraN ( (2.58 AC) ♦ \�
1t i A° s„ ro i G� 1 (Tlzaea.o SO. Fr)��/
Ej I
EXISTING SIGN (PCC)
0
OWNER OFW AIRPORT
NOTES:
I. ALL DOWNSTREAM DRAINAGE ISSUES MUST BE RESOLVED PRIOR TO
ANY OF THE PROPERTIES BEING DEVELOPED.
0 50 100 200
SCALE: 1 " = 100'
NOT FOR CONSTRUCTION
U
Z
cd
g
0
G
PROPOSED DEVELOPMENT RENAISSANCE HOTEL
SILVER LAKE CROSSINGS ADDITION LOT $ BLOCK I
SILVERLAKE CROSSINGS RENAISSANCE HOTEL
SILVER LAKE CROSSINGS ADDITION LOT 2, BLOCK 1
OVERALL SITE DATA
PROPOSED LAND USE: HOTEL
PROPOSED LAND USE: HOTEL
EXISTING ZONING: COMMUNITY COMMERCIAL (CC)
-
LOTAREA
PROPOSED ZONING: COMMERCIAL CENTER WI PD OVERLAY
SITE DATA
PROPOSED ZONING. PCC W/ PD OVERLAY'
LOTAREA
SF
AC
LOTAREA
939,482.00
21.6
MAIN HOTEL BUILDING HEIGHT (FT)
114'-0"
50'-0"
PARKING GARAGE BUILDING HEIGHT (FT)
47'-0"
50'-0"
AC
9.66
PROVIDED
REQUIRED
TOTAL OPEN SPACE (SF)
731,801.00
281,844.60
(30% Min. Required)
77.9%
30,0%
TOTALIMPERVIOUS AREA(SF)
207,681.00
751,585.60
(Not to Exceed 80%)
22.1%
80.0%
PARKING GARAGE FIRST FLOOR FOOTPRINT
25,130.00
25,6%
BUILDING FIRST FLOOR FOOTPRINT
66,660.00
5.6%
TOTAL FIRST FLOOR FOOTPRINT
91,790.00
563,689.20
(Not to Exceed 60%)
9.8%
60.0%
FLOOR AREA RATIO (BUILDING/LOT SIZE)
0.098:1
REQUIRED
MAIN HOTEL TOTAL BUILDING AREA(SF)
245,705
N/A
PARKING GARAGE TOTAL BUILDING AREA(SF)
89,120
(30% Min. Required)
NUMBER OF PARKING SPACES
284
30.1%
NUMBER OFGUESTROOMS
300
300
GUESTROOMS (SF) MIN.
380
380
MEETING/CONFERENCE (SF)
19,687
10,000
RESTAURANT AREA(SF)
4,310
1
....(Full SeNce Kitchen Required)
28,019
100,846
RESTAURANT SEATS
150
14.2
SWIMMING POOL (SF)
2,934
1,000
BUILDINGSETBACKS
0.142:1
-
FRONT YARD (FT)
25
25
SIDE YARD - EACH SIDE (FT)
20
20
REAR YARD (FT)
25
25
PARKING
450
300
GUESTROOMSPACES
300
450
(SPACEIRM)
(11RM)
(1.51RM)
CONFERENCE SPACE (SF)
5,000
15,000
(NO ADDITIONAL REQ'D)
RESTAURANT AREA(SF)
2,506
RESTAURANT SEATING SPACES
50
50
(SPACE/SEATS)
(1 SPACE 13 SEATS)
(1 SPACE 13 SEATS)
PARKING TOTAL (INCL. ADA)
350*
Sao
SURFACE PARKING (0 OF SPACES)
164
1,000
PARKING GARAGE (# OF SPACES)
186
- -
SHARED PARKING W/ LOT 1A, BLOCK 1 (# OF SPACES)
98
PARKING TOTAL PROVIDEDIREQ'D WITH LOT 1A, BLOCK 1
448
25'
* PARKING REQUIRED AT 1 SPACE PER GUESTROOM REDUCTION
654
EXISTING COURTYARD MARRIOTT] TOWNEPLACE SUITES &
PROPOSED DEVELOPMENT HILTON GARDEN INN HOTEL EXPANSION
SILVER LAKE CROSSINGS ADDITION LOT 1A, BLOCK i
SILVER LAKE CROSSINGS MULTI -BRAND HOTEL - HILTON GARDEN INN 150 RM EXPANSION
SILVER LAKE CROSSINGS ADDITION LOT IA, BLOCK 1
OVERALL SITE DATA
PROPOSED LAND USE MULTI -FAMILY
PROPOSED LAND USE: HOTEL
EXISTING ZONING: COMMUNITY COMMERCIAL
-
LOTAREA
EXISTING ZONING: PLANNED COMMERGAL CENTER (PCC)
SITE DATA
PROPOSED ZONING. PCC W/ PD OVERLAY'
LOTAREA
SF
591,163.00
AC
13.57
SITE DATA
PROVIDED
REQUIRED
BUILDING HEIGHT (Fr)
55'4" (4 STORIES)
LOTAREA
SF
420,654.00
45'4" (3 STORIES)
AC
9.66
26.5
PROVIDED
'
REQUIRED
EXISTING COURTYARD MARRIOTT /
TOW NEPLACE SUITES HOTEL
#
%
EFFICIENCY (625 - 700) SF
53
BUILDING HEIGHT (FT)
69'-6"
194
54.0%
50'-0"
HILTON GARDEN INN
25,6%
THREE BEDROOM (1,945) SF (BROWNSTONES)
20
5.6%
BUILDING HEIGHT (FT)
69'-0"
100%
50'-0"
188,563.001 4.33
EXISTING COURTYARD
MARRIOTTI
TOWNEPLACESUITES NILTONGARDENINN150
HOTEL RM EXPANSION
PROVIDED PROVIDE)
TOTAL
REQUIRED
TOTAL OPEN SPACE (SF)
34%
-
126,527,00
126,196.20
(30% Min. Required)
(250 SF/DWELLING UNIT)
-
30.1%
30% min
TOTAL IMPERVIOUS AREA(SF)
295,793.93
-
294,127.00
336,523.20
(Not to En:eed 80%)
391,742.76
-
69.9%
80% max
FIRST FLOOR FOOTPRINT
59,916
28,019
100,846
252,392.40
(Not to Freed 60%)
14.2
6.7%
20.9%
60%
FLOOR AREARATIO(BUILDING/LOT SIZE)
0.142:1
-
0.209'1
25
TOTAL BUILDING AREA(SF)
225,511
108,282
333,793
REAR YARD (FT)
NUMBER OF-GUESTROOMS
300
150
450
300
GUESTROOMS (SF) MIN.
380
380
-
360
MEETING/CONFERENCE(SF)
10,000
5,000
15,000
10,000
RESTAURANT AREA(SF)
2,506
2,500
5,006
1
RESTAURANT SEATS
100
25
125
59,916 1 28,019
SWIMMING POOL (SF)
1,000
179,725
1,000
1,000
BUILDING SETBACKS
- -
FRONTYARD
25'
25'
TOTAL BUILDING AREA(SF)
654
SIDEYARb(2)
20'
20'
-
20'
REAR YARD
25'
25'
NUMBER OF RESTAURANT SEATS
25'
PARKING
275
GUESTROOMS (SF) MIN.
380 380
GUESTROOMSPACES
300
150
450
675
(SPACE/RM)
(1/RM)
(1/RMI
(IIRM)
(1.5/RM)
CONFERENCE SPACE (SF)
6,816
SWIMMING POOL (SF)
1,000
(NO ADDITIONAL REQ'D)
3,934
TOTAL PARKING
394
RESTAURANT SEATING SPACES
34
8
42
42
(SPACE/SEATS)
(1 SPACE 13 SEATS) (1 SPACE 13 SEATS)
(I SPACE/3 SEATS)
TOTAL PARKING
492"*
717
TOTAL ON-SITE PARKING
394
LOT 2, BLOCK 1 OFFSITE PARKING
(PARKING GARAGE)
98
' INTENDED TO AMEND PREVIOUSLY APPROVED PCC FOR 160 ROOM HOTEL EXPANSION
" PARKING REQUIRED AT 1 SPACE PER GUESTROOM REDUCTION
PLANNED COMMERCIAL CENTER TOTAL TABULATIONS:
PROPOSED DEVELOPMENT.. MULTI -FAMILY HOUSING
THE BLUFFS AT GRAPEVINE LOT 1A1, BLOCK I
SILVER LAKE CROSSINGS MULTI -FAMILY DEVELOPMENT
THE BLUFFS AT GRAPEVINE LOT 1A1, BLOCK 1
OVERALL SITE DATA
PROPOSED LAND USE MULTI -FAMILY
EXISTING ZONING: COMMUNITY COMMERCIAL
-
LOTAREA
PROPOSED ZONING: RMFWIPDOVERLAY
SITE DATA
SF AC
LOTAREA
SF
591,163.00
AC
13.57
SEE BELOW SEE BELOW
PROVIDED
REQUIRED
BUILDING HEIGHT (Fr)
55'4" (4 STORIES)
35'-0" (2 STORIES)
45'4" (3 STORIES)
MAXIMUM DENSITY(UNITS/ACRE)
26.5
20.0
'
SILVER LAKE CROSSINGS ADDN. LOT 1A, BLOCK 1
UNIT MIX BREAKDOWN
#
%
EFFICIENCY (625 - 700) SF
53
14.8%
ONE BEDROOM (750 - 1,006) SF
194
54.0%
TWO BEDROOM (1,027 -1,291) SF
92
25,6%
THREE BEDROOM (1,945) SF (BROWNSTONES)
20
5.6%
TOTAL NUMBER OF DWELLING UNITS
359
100%
THE BLUFFS AT GRAPEVINE LOT 1A2, BLOCK 1
188,563.001 4.33
TOTAL OPEN SPACE (SF)
199,42024
118,317.57
(20%Min. Required)
34%
20%
USABLE OPEN SPACE (SF)
319
250
(250 SF/DWELLING UNIT)
-
-
FIRST FLOOR FOOTPRINT (SF)
148,199.00
295,793.93
(Not to Exceed 50%)
25%
50%
TOTAL IMPERVIOUS AREA(SF)
391,742.76
443,690.89
(Not to Exceed 75%)
66%75%
TOTAL BUILDING AREA(SF)
492,313.00
-
FLOOR AREA RATIO (BUILDINGILOT SIZE)
0.25:1
-
GRAPEVINELOT GRAPEVINE LOT
BUILDING SETBACKS
150 RM EXPANSION
RENAISSANCE HOTEL
FRONTYARD (FT)
25
40
SIDE YARD -EACH SIDE (Fr)
20
20
REAR YARD (FT)
30
30
PARKING DATA
114'-0" (MAIN HOTEL)
ATTACHED GARAGE
120
-
SURFACE PARKING (INCL. ADA)
468
-
PARKINGTOTAL588
718
(SPACEIDWELLING UNIT)
(1.6/DU)
(21DU)
SILVER LAKE CROSSINGS PLANNED COMMERCIAL CENTER
OVERALL SITE DATA
LOTAREA
SF AC
EXISTING COURTYARD MARRIOTT I TOWNEPLACE
SEE BELOW SEE BELOW
SUITES HOTEL
HILTON GARDEN INN HOTEL EXPANSION
'
SILVER LAKE CROSSINGS ADDN. LOT 1A, BLOCK 1
420,654.00 9.66
RENAISSANCE HOTEL
SILVERLAKE CROSSINGS ADDN. LOT 2, BLOCK 1
939,482.00 21.6
THE BLUFFS AT GRAPEVINE LOT 1A2, BLOCK 1
188,563.001 4.33
THE BLUFFS AT GRAPEVINE LOT 2A2, BLOCK 1
112,383.00 2.58
EXISTING
COURTYARD
MARRIOTT/
THE BLUFFS AT THEBLUFTSAT
TOWNEPLACE
HILTONGARDElINN
GRAPEVINELOT GRAPEVINE LOT
SUITES HOTEL
150 RM EXPANSION
RENAISSANCE HOTEL
1A2, BLOCK 1 2A2, BLOCK I
PROVIDED
PROVIDED
PROVIDED
PROVIDED PROVIDED
ON-SITETOTAL
114'-0" (MAIN HOTEL)
- -
BUILDING HEIGHT (FT)
691-6"
69'-0"
47'-0" (PARKING GARAGE)
TOTAL OPEN SPACE (SF)
126,527.00
731,801.00
188,563.00 112,383.00
1,159,274.00
TOTAL IMPERVIOUS AREA(SF)
294,127.OD
207,681.00
0 0
501,808.00
TOTAL FIRST FLOOR FOOTPRINT
59,916 1 28,019
91,790.00
- -
179,725
FLOOR AREARATIO(BUILDINGILOT SIZE)
0.142:1
0.098:1
- -
245,705 (MAIN HOTEL)
- -
333,793
TOTAL BUILDING AREA(SF)
225,511 108,282
89,120 (PARKING GARAGE)
NUMBER OF GUESTROOMS
300 150
300
-
750
NUMBER OF RESTAURANT SEATS
100 25
150
275
GUESTROOMS (SF) MIN.
380 380
380
MEETING/CONFERENCE (SF)
10.000 5,000
19,687
34,687
RESTAURANT AREA (SF)2,506
-
4,310
6,816
SWIMMING POOL (SF)
1,000
2,934
3,934
TOTAL PARKING
394
448
842*
* TOTAL PARKING REQUIRED I PROVIDED AT 1 SPACE PER GUESTROOM & 1 SPACE PER 3 RESTAURANT SEATS
NOT FOR CONSTRUCTION
0
PROPOSED DEVELOPMENT.' RENAISSANCE HOTEL
SILVER LAKE CROSSINGS ADDITION LOT Z BLOCK 1
CONDITIONAL USE PERMIT REQUEST
SECTION.
REGULATION
PROPOSED DEVIATION
EXPLANATION
25 t CA.
Alcohol beverage sales may be permitted
Alcohol beverage sales will be
The hotel will provide a high-
56 / C.
Ixovided a special permit is Issued in
provided on the conditions of
end restaurant and bar to
58.
accordance with Section 42. B. of this
acquinng a special permit In
serve hotel and outside
Ordinance,
accordance with Section 42.81 of
guests.
22/G.
53 of the Zoning Ordinance.
this Ordinance.
adequately supported by a
251 C.16.
Restaurant with outside dining andfor drive
The Restaurant will pradde
The lake at Silver Lake
through may be permitted provided the
outside dining on the condition
crossNgs provides a unique
provisions of Section 48 of the Zoning
that the provisions of Section 48
amenity to Hotel properly.
Ordinance are met.
of the Zoning Ordinance are met.
Positioned at high elevetian
22/1.3
Motels or hotels with conference faciliities
Off street parking shall be
above the take, the restaurant
with less than 25,E sq, ft, of conference
provided at a ration of 1 parking
and bar have 180- degree views
area shall provide 1.5 parking spaces per
space per guest room, plus
of the property's natural
guest room, plus requirements for eating
requirements for an eating or
landscape and having an
or drinking establishments,
drinking estabiishmem.
outdoor dining experience will
degrees and under no circumstances shall a
(40) degrees and under no circumstances shall
help to contract the guests to
cluster of buildings exceed two hundred (250)
a cluster of buildings exceed eight hundred
the outdoors.
25 / C.19.
Structures in excess of fifty (50) feel in
The hotel simchar, Is 114'-0" In
The site drops in elevation and
22/1.1.
height may be permitted provided the
height.
limits the area in which a
provisions of Section 48 of the Zoning
maximum height regulations shall be
feasible stmctum can be built.
Ordinance are met.
observed:
In order to accommodate 300
L The maximum height ofthe principal
1. Exceptas provided below, the maximum
keys, the hotel structure
structure shall be two (2) stories not to
structure height shall be three (3) stories not
needs 7 floors of guest roans
exceed thirty-five(35)feet.
to exceed forty-five(45) feet, The maximum
above the ground level.
25! C.24.
Any use allowed within this district with
Outdoor speakers will be
Outdoor speakers will be
outdoor speakers may be permitted
provided on the condition of
positions in the soffit of the
provided the provisions of $sell- 48 of the
acquinng a special permit in
covered outdoor dining temice
Zoning Ordinance am met.
accordance with Section 48 of
outside the restaurant as well
22/J
OFF-STREET PARKING: Off-street parking
this Ordinance.
11 1, the safit of the covered
shall be provided in accordance with the
be provided in accordance with the provisions
outdoor tem me adjacent to the
22/M.6
provisions of Section 56 and 58 ofthis
of Section 56 and 58 of this Ordinance and
lobby lounge.
PLANNED DEVELOPMENT OVERLAY VARIANCE REQUEST
SECTION
REGULATION
PROPOSED DEVIATION.
EXPLANATION
25 / K,
OFFSTREET PARKING: Off-street parking
OFFSTREET PARKING,. Off-
Based on a parking study
56 / C.
shall be provided in accordance with the
street parking shall be provided
completed on July 19, 2016 by
58.
protisions of Sections 56 and 58 and shall
in accordance with the
Hunt-Zoilars, Inc. the
be landscaped In accordance with Section
provisions of Sections 56 and 58
development can be
22/G.
53 of the Zoning Ordinance.
and shall be landscaped In
adequately supported by a
standards shall be required.
accordance with Section 53 of
reduction of 1 space per
L Depth of front yard, feet -40
this Ordinance.
guestoom. Reductions in
areas. Maximum width for accessways shall
OR street parking shall be prWried
parking requirements are
be twenty-five (25) feet.
6. Stoops, retaining walls, awnings, raised
based on the actual usage of
22/1.3
Motels or hotels with conference faciliities
Off street parking shall be
the existing Courtyard
with less than 25,E sq, ft, of conference
provided at a ration of 1 parking
ManiotU Townepiace Suites
area shall provide 1.5 parking spaces per
space per guest room, plus
hotel. Shared parking
guest room, plus requirements for eating
requirements for an eating or
agreement parking spaces for
or drinking establishments,
drinking estabiishmem.
Lot 1A, Block 1 will be utilized
degrees and under no circumstances shall a
(40) degrees and under no circumstances shall
via Lot 2, Block L
PROPOSED DEVELOPMENT: MUL77—FAMILY HOUSING
THE BLUFFS AT GRAPEVINE LOT IA i, BLOCK 1
CONDITIONAL USE PERMIT REQUEST
SECTION
REGULATION
PROPOSED DEVIATION
EXPLANATION
22/F.l.d.
The maximum density within the R -MF
The maximum density within the R-MFDistrict
At27umts peracre, Silver Lake Crossings
561 C.
Districtshall not exceed twenty(20)dwelling
shall notexceed(27) dweliingunits pergross
will providethe appropriate amountof
58.
units pergrossacm.
am.
residential density to support the mix of
feet in width shall be maintained between
Sections 56 and 58 and shall be
other uses in the master plan.
22/G.
AREA REGULATIONS: The following minimum
AREA REGULATIONS: The following minimum
Silver Lake Crossings has been designed
standards shall be required.
standards shall be required,
with new urbanist principals. The
L Depth of front yard, feet -40
L Depth affront yard, feet -25
planning methodology pushes the
areas. Maximum width for accessways shall
OR street parking shall be prWried
buildings up to the streets, to create the
be twenty-five (25) feet.
6. Stoops, retaining walls, awnings, raised
street edge and define the pedestrian
22/1.3
The maximum length of any building shall not
planters, sculptures, and other decorative
zone. Additionally, a number of units on
exceed two hundred (200) linear feet. Such
landscape items may be located within the
the ground floorwill have direct access
limitation shall apply to any duster of
required front yard setback.
to the right of way which activates the
attached buildings unless there is a break In
attached buildings unless there are two (2)
streets. The parking for the project has
the deflection angle ofat least twenty(20)
breaks in the deflection angle of at leastforty
been internalized be hind the buildings.
degrees and under no circumstances shall a
(40) degrees and under no circumstances shall
In order to achieve these design
cluster of buildings exceed two hundred (250)
a cluster of buildings exceed eight hundred
concepts, a modification to the front
feet In length.
(800) feet in length.
yard setback is necessary.
22/1.1.
HEIGHT REGULATIONS: The following
HEIGHT REGULATIONS: The following
Providing a variation is height creates
maximum height regulations shall be
maximum height regulations shall be
architectural interest. The taller
observed:
observed:
buildings are a more appropriate scale
L The maximum height ofthe principal
1. Exceptas provided below, the maximum
forthe mix of uses in the masterpian.
structure shall be two (2) stories not to
structure height shall be three (3) stories not
The majority of the buildings will be
exceed thirty-five(35)feet.
to exceed forty-five(45) feet, The maximum
three stories and only the main building
height of the principal structure (leasing/ club
will be four stories. The additional
/ fitness building) shall be four (4) stories not
height will provide greatervisibility for
to exceed fifty-five (55) feet.
the residential buildings above the
proposed restaurants.
22/J
OFF-STREET PARKING: Off-street parking
OFF-STREET PARKING: Off-street parking shall
Adequate parkingis critical for a rental
shall be provided in accordance with the
be provided in accordance with the provisions
residential development. Based on our
22/M.6
provisions of Section 56 and 58 ofthis
of Section 56 and 58 of this Ordinance and
experience and current market
Ordinance and other applicable ordinances of
otherapplicable ordinances of the City.
conditions, the proposed reduced ratio is
the City.
feet. Whenever two (2) principal structures
sufficient for the number of units and
Is greater. Whenevertwo(2) principal
are arranged face-to-face or back-to-back, the
the unit mix proposed. The goal is to
structures are arranged face-to-face or back-
minimum distance shall be forty(40)feet.
provide one car per bedroom and an
56/C.1
Off street parking shall be provided at a ratio
Off street parking shall be provided at a ratio
additional ratio of 0.25 spaces per unit
of 2.0 parking spaces per dwelling unit.
of L6 parking spaces per dwelling unit.
for visitor parking. These parameters
exterior walls of the buil dings and does not
include balconies, railings, orother
will yield a total of approximately 1.6
include balconies, railings, or other
architectural features.
spaces per unit for this development.
PLANNED DEVELOPMENT OVERLAY VARIANCE REQUEST
SECDON
REGULATION
PROPOSED DEVIATION
EXPLANATION
531 H.2.b.
Wheneveran off-street parking or vehicular
Accessways between lots may be permitted
An access easement will be provided
561 C.
use areas abuts an adjacent property linea
through all perimeter landscape areas.
between the multi -family development
58.
perimeter landscape area of at leastten (10)
accordance with the provisions of
and the proposed restaurant pad site in
feet in width shall be maintained between
Sections 56 and 58 and shall be
lieu of the landscape area. The
the edge of the parking area and the adjacent
landscaped in accordance with
minimum width of the provided access
property line. Amssways between lots may
Section 53 of this Ordinance.
easement will be 27 feet.
be permitted through all perimeter landscape
usage of the existing Courtyard Marriott f
areas. Maximum width for accessways shall
OR street parking shall be prWried
Towneplace Suites hotel. Shared parking
be twenty-five (25) feet.
at a ration of 1 parking space per
89mement parking spaces will be utilized
22/1.3
The maximum length of any building shall not
The maximum length of any building shall not
The additional length applies mostly to
exceed two hundred (200) linear feet. Such
exceed three hundred (300) Iinearfeet. Such
the main leasing building. The
limitation shall apply to any duster of
limitation shall apply to any ciusterof
additional length allows for a larger
attached buildings unless there is a break In
attached buildings unless there are two (2)
courtyard area and more unitviews
the deflection angle ofat least twenty(20)
breaks in the deflection angle of at leastforty
toward project amenity areas. This helps
degrees and under no circumstances shall a
(40) degrees and under no circumstances shall
mate a more expansive recreational
cluster of buildings exceed two hundred (250)
a cluster of buildings exceed eight hundred
open space for the residents to enjoy.
feet In length.
(800) feet in length.
22/NLS
No building shall be located closer than
No minimum distance between the building
There will be no minimum distance
fifteen (15) feet to the edge of an off-street
and the off-street parking orvehicular use,
between buildings and vehicular uses.
parking, vehicular use, orstorage area.
We have located a number of the
buildings along the pedestrian ways to
create a boulevard feel, which
encourages pedestrian interaction.
Additionally, there are areas where the
building is adjacent to the drive aisle
with tuck-undergarages. In these cases,
the separation needs to be reduced to
provide a more efficient street
configuration.
22/M.6
The minimum distance between two (2)
The minimum distance between any two (2)
Due to the additional building height,
unattached buildings shall be twenty(20)
unattached buildings shall be twenty(20)
the removal of the term"orthe height of
feet orthe height of the building whichever
feet. Whenever two (2) principal structures
the building, whichever is greatest"
Is greater. Whenevertwo(2) principal
are arranged face-to-face or back-to-back, the
al lows for a more effidently planned
structures are arranged face-to-face or back-
minimum distance shall be forty(40)feet.
community. Allowing buildings to be
to -back, the mini mum distance shall be (50)
The point of measurement shall be the
closer together allows a planner to
feet. The point of measurement shall bethe
exterior wails of the buildings and does not
create spacesthat have agreatersense
exterior walls of the buil dings and does not
include balconies, railings, orother
of enclosure, more variety and more
include balconies, railings, or other
architectural features.
urban scale.
architectual features.
EXiS77NG COURTYARD MARRIOTT/ TOWNEPLACE SUITES &
PROPOSED DEVELOPMENT HILTON GARDEN INN HOTEL EXPANSION
SILVER LAKE CROSSINGS ADDIT70N LOT IA, BLOCK i
CONDITIONAL USE PERMIT REQUEST
SECTION
REGULATION
PROPOSED DEVIATION
EXPLANATION
25 t C.19.
Structures in excess of fifty (50) feet
The requested maximum height is
The amhitecture of the expansion
561 C.
in height maybe be permitted,
70 feet.
requires the building to be the same
58.
provided they meet the provisions of,
accordance with the provisions of
height. The existing building has a height
and Conditional Use Permit is
Sections 56 and 58 and shall be
not to exceed 70 feet.
issued pursuant to, Section 48 of
landscaped in accordance with
guestoom. Reductions in parking
the Ordinance.
Section 53 of this Ordinance.
requirements are based on the actual
PLANNED DEVELOPMENT OVERLAY VARIANCE REQUEST
SECTION
REGULATION
PROPOSED DEVIATION
EXPLANATION
251 K.
OFFSTREET PARKING: Oft -street
OFFSTREET PARKING: Off-street
Based on a parking study completed on
561 C.
parking shall be provided in
parking shall be provided in
July 19, 2016 by Hunt-Zollars. Inc, the
58.
accordance with the provisions of
accordance with the provisions of
development can be adequately
Sections 56 and 58 and shall be
Sections 56 and 58 and shall be
supported by a reduction of 1 space per
landscaped In accordance with
landscaped in accordance with
guestoom. Reductions in parking
Section 53 of the Zoning Ordinance.
Section 53 of this Ordinance.
requirements are based on the actual
usage of the existing Courtyard Marriott f
Motels or hotels with conference
OR street parking shall be prWried
Towneplace Suites hotel. Shared parking
facillities with less than 25,000 sq.
at a ration of 1 parking space per
89mement parking spaces will be utilized
ft. of conference area shall provide
guest room, plus requirements for
via Lot 2, Block 1.
1S parking spaces per guest mom,
an eating or drinking
plus requirements for eating or
establishment.
drinking establishments.
NOT FOR CONSTRUCTION
CiTY OF GRAPEVINE
100 -YR FLOOD EASEMENT -\/"I
.o rj
S=UPAHKINUVNLOI IPULO Ki(9OF SPADES) 98 / t� `\
PARKING TOTAL PROEO'
VIDEDfRDWTTH LOT10.8LOCK 1 448 ✓ I `VARIABLE WIDTH PUBLIC
• PARKINGREQUIREDATI SPACE PER GUESTROOM REDUCTIONf
/ f � ACCESS & DRAINAGE
EASEMENT
��l /
aki.
NE
8' PAINTED
CONCRETE#
aREN
LOADING
,� f
/
/
DOCK
i
TRASH
9' MAX HT. MODULAR
BLOCK RETAINING WALL
o
o , i t 1 CONFERENCE SPACE i Y ak` � k� T \,, Tl s
.�1.�
",
'hM1i 5' SIDEWALK
„ W ,
'� T,��, StLVERLAKE CROSSINGS ADDITION
70' LANDSCAPE a
DnRE ynam •c�l .„ =h,•,;,U etl.,,ti;+A
'a�4i,
s
..s.v,•.
_
5' SIDEWALK -
BUFFER WR ,
.
ni
a
s < t SANITARY
P S 7
P'
4
te,; tt`,m. 1�t tt�. ., SEWER
i t
0 5, T i
r l
t
a
„.P N
RATE LIFT
t +
SEE NOTE 11
M 6
h, 2
20` BLDG SETBACK 4 a- A t 0 FIRE STATION
1� 3=fit k�k��ai� `ktsi ('�i `xs m#, NE
MAIN SEE NOTE 11
” a CONFERENCE .a
24' FIRE LANE ' .. tii ,-. tl i:' bi3fi M1 �t CENTER EN1RY o, 2' MAX HT.
t. a i tt # # i MODULAR BLOCK
n
�7sRETAINING WALL
t tw 5" SIDEWALK
NOTE 12
N89'51 '35'W 474.49'
W
N
VARIABLE WIDTH PUBLIC
ACCESS EASEMENT—
I I I " : I !
10" MAX HT. MODULAR
BLOCK RETAINING WALL
5'
H
PROPOSEDSIGNfl'•;n
16
LOT IA
BLK I
SILVERLAKE CROSSINGS AO0177ON 1Till 1.
/ l V
///,', /
/ ��,• EXISTING LAKE
' WSE = 507.10"
'LIC TRAIL SYSTEM
Ia
I I
IEWALK
�s
NOT FOR CONSTRUCTION
u i
�`
0
OWNER/DEVELOPER:
'II
c3
KINWEST PARKWAY, SUITE 150
1RV/NG, TEXAS 75063
s KIMBERLY R. COLE i
�•-r•••••-•••••••••••-••r••�
t i
PHONE(2 f 4) 774-4650
LLt�''o �, 105298
E,
FAX: (214) 260-3724
CONTACT:
U.
t4i
MEHUL PATEL
;A` .Iv
T
9
REVISIONS
RE FlR
DATE BY
OI
FIRE
SANITARY Z
SEWER I(
N
PUBLIC LIFT
_
STATION
�(I
III
j
s
ro
r-
a
c.5
o
®
1 GO
I I
5,
N
NOTE 12
N89'51 '35'W 474.49'
W
N
VARIABLE WIDTH PUBLIC
ACCESS EASEMENT—
I I I " : I !
10" MAX HT. MODULAR
BLOCK RETAINING WALL
5'
H
PROPOSEDSIGNfl'•;n
16
LOT IA
BLK I
SILVERLAKE CROSSINGS AO0177ON 1Till 1.
/ l V
///,', /
/ ��,• EXISTING LAKE
' WSE = 507.10"
'LIC TRAIL SYSTEM
Ia
I I
IEWALK
�s
NOT FOR CONSTRUCTION
u i
�`
Of�ltl
OWNER/DEVELOPER:
'II
i°°•e............. ... e...�
KINWEST PARKWAY, SUITE 150
1RV/NG, TEXAS 75063
s KIMBERLY R. COLE i
�•-r•••••-•••••••••••-••r••�
t i
PHONE(2 f 4) 774-4650
LLt�''o �, 105298
E,
FAX: (214) 260-3724
CONTACT:
U.
t4i
MEHUL PATEL
;A` .Iv
T
Hmtt zllors, mo.
Flrm Registration No. F-761
REVISIONS
NO. DESCRIPTION
DATE BY
I
FIRE
SANITARY Z
SEWER I(
LANE
PUBLIC LIFT
_
STATION
�(I
III
0
I I
5,
r
LEGEND
i PROPERTY LINE
E- VEHICULAR FLOW
-FlRE FIRE LANE
PROPOSED BUILDING
NOTES
1. OWNER IS REQUESTING VARIANCE TO HEIGHT RESTRICTION TO ALLOW
FOR A MAXIMUM HEIGHT OF 114 FEET. REFER TO SHEET 4 FOR
DETAILED EXPLANATION,
2, OWNER IS REQUESTING VARIANCE TO OFF-STREET PARKING
REQUIREMENT TO ALLOW FOR A RATIO OF 1 SPACE PER GUESTROOM.
REFER TO SHEET 4 FOR DETAILED EXPLANATION.
3. CURRENT ZONING: CC" COMMUNITY COMMERCIAL: CURRENT USE.-
VACANT,'
SEVACANT,' PROPOSED ZONING: PART OF PLANNED COMMUNITY CENTER,
PROPOSED USE: HOTEL WITH RESTAURANT AND CONFERENCE SPACE
4. ALL ON-SITE ELECTRICAL CONDUCTORS ASSOCIATED WITH NEW
CONSTRUCTION SHALL BE LOCATED UNDERGROUND.
5. ALL TRANSFORMERS SHALL BE SCREENED PER CITY REQUIREMENTS.
6. CONDITIONAL USE REQUEST CUP16-22 IS A REQUEST TO ESTABLISH A
300 ROOM HOTEL (RENAISSANCE HOTEL) WITH THE POSSESSION,
STORAGE, RETAIL SALES AND ON -PREMISE CONSUMPTION OF
ALCOHOLIC BEVERAGES (BEER, WINE, MIXED BEVERAGES) IN
CONJUNCTION WITH A RESTAURANT OUTDOOR PATIO SEATING, OUTDOOR
SPEAKERS, AND AN INCREASE IN HEIGHT
7. PLANNED DEVELOPMENT OVERLAY PD16-07 IS A REQUEST TO DEVIATE
FROM BUT NOT BE LIMITED TO A REDUCTION IN THE AMOUNT OF
PARKING PROVIDED BELOW THAT REQUIRED BY ORDINANCE.
B. THE ENTIRE SITE IS THE PREMISE.
9. ALL THE REQUIREMENTS OF THE GRAPEVINE SOIL EROSION CONTROL
ORDINANCE SHALL BE MET DURING THE PERIOD OF CONSTRUCTION
10, MAXIMUM SIZE FOR SIGNAGE IS 60 SF WITH A HEIGHT NO GREATER
THAN 6 FEET: ALL SIGNS SHALL BE 15' SETBACK FROM ALL
PROPERTY LINES.
11, HOTEL SIGNAGE ON WALL. REFER TO ARCH FOR StGNAGE DETAILS.
12. CONFERENCE CENTER SIGNAGE. REFER TO ARCH FOR SIGNAGE DETAILS.
13. OWNER UNDERSTANDS THAT ALL DOWNSTREAM DRAINAGE ISSUES MUST
BE RESOLVED PRIOR TO ANY OF THE PROPER77ES BEiNG DEVELOPED.
14, SITE WILL COMPLY WITH ALL FAA HEIGHT GUIDELINES.
0 20 40 80
SCALE: 1" = 40'
ItCASE NAME; SILVEtt tN¢ cRosswcs/RRlWG.4WCE xora
CASE NUMBER cute—xz, role w
LOCATION: a PPO aaURr, IDT Z, BLOCK t,
SILVER INCE CROCSIN0.S IDCn10N
iMAYOR SECRETARY
„qFf PLANNING AND ZONING COMMISSION
DATE:
SHEET.--!—OF--L
T:aOFtom
APPROVAL DOES NOT AUTHORIZE ANY WORK
IN CONFLICT ANY CODES OR
ORDINANCES.
DEPARTMENT OF DEVELOPMENT SERVICES
CUP 300 ROOM HOTEL SUBMITTAL
SITE PLAN
HUITT-ZOLLARS
Huitt–Zollars, Inc. Engineering / Architecture
500 W. 7th St, Ste. 300 Fort Worth, Texas 76102
Phone (817)335-3000 Fax (817)335-1025
AS SHOWN 108/01/20165 OFOF 7
NOT FOR CONSTRUCTION
�`
Of�ltl
OWNER/DEVELOPER:
SUPREME BRIGHT GRAPEVINE Ill, LLC
1135
i°°•e............. ... e...�
KINWEST PARKWAY, SUITE 150
1RV/NG, TEXAS 75063
s KIMBERLY R. COLE i
�•-r•••••-•••••••••••-••r••�
t i
PHONE(2 f 4) 774-4650
LLt�''o �, 105298
E,
FAX: (214) 260-3724
CONTACT:
U.
t4i
MEHUL PATEL
;A` .Iv
EMAIL: mehut®nchLnet
}.1
Hmtt zllors, mo.
Flrm Registration No. F-761
REVISIONS
NO. DESCRIPTION
DATE BY
0 20 40 80
SCALE: 1" = 40'
ItCASE NAME; SILVEtt tN¢ cRosswcs/RRlWG.4WCE xora
CASE NUMBER cute—xz, role w
LOCATION: a PPO aaURr, IDT Z, BLOCK t,
SILVER INCE CROCSIN0.S IDCn10N
iMAYOR SECRETARY
„qFf PLANNING AND ZONING COMMISSION
DATE:
SHEET.--!—OF--L
T:aOFtom
APPROVAL DOES NOT AUTHORIZE ANY WORK
IN CONFLICT ANY CODES OR
ORDINANCES.
DEPARTMENT OF DEVELOPMENT SERVICES
CUP 300 ROOM HOTEL SUBMITTAL
SITE PLAN
HUITT-ZOLLARS
Huitt–Zollars, Inc. Engineering / Architecture
500 W. 7th St, Ste. 300 Fort Worth, Texas 76102
Phone (817)335-3000 Fax (817)335-1025
AS SHOWN 108/01/20165 OFOF 7
,w10119AZ-1 2 %
0
INTERIOR TREE
PERIMETER TREE
NOT FOR CONSTRUCTION
NON -VEHICULAR OPEN SPACE TREE
®
FEATURE LANDSCAPE AREA
1
/
/
IY ABUTMENTEASEMENT
X
7 F l
---DENSE TREES TO REMAIN
rAl
Y_y
SHEET 6 OF 16
NOT FOR CONSTRUCTION
Y a
IV ABUTMENT EASEMENT
C u
/
�4 SO
(7 �A
oY �
1
/
/
IY ABUTMENTEASEMENT
X
7 F l
---DENSE TREES TO REMAIN
rAl
Y_y
SHEET 6 OF 16
NOT FOR CONSTRUCTION
1
rr
C u
/
�4 SO
(7 �A
oY �
1135 KINWEST PARKWAY, SUITE 150
�• .p
0
IPA 0
TpTe
PHONE.• (214) 774-4650
19 ABUTMENTi SEMENT
FAX: (214) 260-3724
OF
CONTACT: MEHUL PATEL
�
1
,
Huitt-Zollam, Inc. - Firm Registration No. F-761
REVISIONS
NO. DESCRIPTION
DATE I BY
1
� z
15 BUTMENT EASEM NT
7-1
( y
LANDSCAPE REQUIREMENTS
PERIMETER LANDSCAPING' PARKING/VEHICULAR USE AREAS MUST BE
SCREENED FROM ABUTTING PROPERTIES AND/OR PUBLIC RIGHTS OF WAY
15 ABUTTMENT EASEMENT AT R.O.W.
10' ABUTTMENT EASEMENT A PL FROM ADJACENT PROPERTIES
(1) TREE FOR EVERY 50 LF -5,200 / 50 =
REQUIRED: 109 TREES
PROVIDED: 34 TREES*
*REMAINING PORTION COVERED IN DENSE EXISTING TREES & WATER TO
REMAIN.
NON -VEHICULAR OPEN SPACP
15% OF TOTAL SITE AREA DEVOTED TO FEATURE LANDSCAPING, 50% TO BE
PROVIDED IN FRONT YARD
SITE AREA: 939,482 SF
REQUIRED: 281,844.60 SF
PROVIDED: 731,801 SF
TREE REQUIREMENTS FOR NON -VEHICULAR OPEN SPACE
% OF SITE IN VEHICULAR SPACE = 14.05% (VEH 132,008 SF)
-1 TREE PER 2,500 SF OF NON -VEHICULAR OPEN SPACE FOR SITES WITH
LESS THAN 30% VEHICULAR SPACE
-1 TREE PEP 3000 SF OF NON -VEHICULAR OPEN SPACE FOR SITES WITH
30%-49% VEHICULAR SPACE
-1 TREE PER 4000 SF OF NON -VEHICULAR OPEN SPACE FOR SITES WITH
OVER 50% VEHICULAR SPACE
281, 844.60 / 2500 =
REQUIRED: 113 TREES
PROVIDED: 13 PROPOSED TREES, EXISTING DENSE TREE STAND PRESERVED
INTERIOR LANDSCAPING:
LANDSCAPE 10% OF THE GROSS PARKING AREA INCLUDING DRIVES,
PARKING AND SIDEWALKS
REQUIRED: 13,201 SF
PROVIDED: 18,124 SF
(1) TREE FOR EVERY \400 SF OF INTERIOR LANDSCAPE AREA
REQUIRED: 36 TREES
PROVIDED: 36 TREES
REQUIRED/PROVIDED: PLANTER ISLANDS EVERY 12 SPACES AND AT THE
TERMINUS OF ALL ROWS. ISLANDS MUST CONTAIN (1) TREE, & BE 9'X18'
MINIMUM SIZE
IRRIGATION:
ALL UNPAVED AREAS TO BE IRRIGATED WITH AN UNDERGROUND AUTOMATIC
IRRIGATION SYSTEM WITH RAIN SENSORS AND FREEZE CONTROLS.
IRRIGATION SYSTEM WILL BE WATER EFFICIENT EMPLOYING DRIP IRRIGATION
IN BED AREAS AND WATER EFFICIENT LAWN SPRAY HEADS.
0 20 40 80
SCALE: 1" = 40' CUP 300 ROOM HOTEL SUBMITTAL
LANDSCAPE PLAN
na a�ns InrrsExu
A'CASE NUMBER�cuie-u. Poio-oT
:... ( LOCATION:ans ass Eao worst: wr a„ elncx I,
scum —E ewssncs enomoK
.)� MAYOR SECRETARY
PLANNING AND ZONING COMMISSION
1
CHAIRMAN
''mx.... DATE:
APPROVAL DOES NOT AUTHORIZE ANY WORK
IN CONFLICT WITH ANY CODES OR
ORDINANCES
DEPARTMENT OF DEVELOPMENT SERVICES
t�'� NeWcr�sPFiTu(�
e
Huitt-Zollom, Inc. Engineering / Architecture
500 W. 7th St. Sts. 300 Fort Worth, Texas 76102
Phone (817)335-3000 Fox (817)335-1025
NED: SCALE DATE SHEET
N'
KED: AS SHOWN 08/01/2016 §_.F_12_
SHEET 6 OF 16
NOT FOR CONSTRUCTION
G.
OWNER/DEVELOPER:
GRAPEVINE EQUITY PARTNERS, LLC
�4 SO
(7 �A
oY �
1135 KINWEST PARKWAY, SUITE 150
�• .p
IRVING, TEXAS 75063
IPA 0
TpTe
PHONE.• (214) 774-4650
4 iP
P
FAX: (214) 260-3724
OF
CONTACT: MEHUL PATEL
(, v^° ,„.;a•^' {„,`
EMAIL: mehul*nchi.net
Huitt-Zollam, Inc. - Firm Registration No. F-761
REVISIONS
NO. DESCRIPTION
DATE I BY
0 20 40 80
SCALE: 1" = 40' CUP 300 ROOM HOTEL SUBMITTAL
LANDSCAPE PLAN
na a�ns InrrsExu
A'CASE NUMBER�cuie-u. Poio-oT
:... ( LOCATION:ans ass Eao worst: wr a„ elncx I,
scum —E ewssncs enomoK
.)� MAYOR SECRETARY
PLANNING AND ZONING COMMISSION
1
CHAIRMAN
''mx.... DATE:
APPROVAL DOES NOT AUTHORIZE ANY WORK
IN CONFLICT WITH ANY CODES OR
ORDINANCES
DEPARTMENT OF DEVELOPMENT SERVICES
t�'� NeWcr�sPFiTu(�
e
Huitt-Zollom, Inc. Engineering / Architecture
500 W. 7th St. Sts. 300 Fort Worth, Texas 76102
Phone (817)335-3000 Fox (817)335-1025
NED: SCALE DATE SHEET
N'
KED: AS SHOWN 08/01/2016 §_.F_12_
w
SER7ICE ENTRY
LOAI.AAGDOGK ,.......
TRA.SNCV.VAr70R
8117 PAWED
WWRETECCREEN "sT
WALL .. � LOADING&
RECEF'+1NG
$43 SF
3`
� �.. ALCOH(X
^.; .. _. STOR.
114 BE
16. DRY STGR KFCHEN "
^YOFF ` OFF, AFF. ' „OFF. OFF. ' `OFF, DFF. •... :.-6FF. 4465E
/ ADpdIM& l96SF 165Sf ifi88F tOfl SF tCd SF .re SF I96SF 1985E
EMPLOYEE MEN ELEVLOSBY
SUPPORT CN.-FF0FPfi.F
EMPLOYEE .. 3,962 SF 142SF —._JAN. 423 SF 44's SF
' ENTRE ......._ ...._.,,_ ,:'" '.
Rp SF
" f iSkk.'N1Er
A. BANQUET MGP M}OtaEtt
s STORAGE1678E
& .,ASF �, 4235E
$ BOARD RGCA7 'E' •
461 SF r+" FRONT DESK
' BOARD WWI_ fi"'P-GRT
AV OfNiTROL .,_ t,' 461SF 655- FF
346SF BOARDROOM .>>
--- 5ER'ACE 576R 487 SF
CORRIDOR
¢ P 7,7334E
LUGS.
133 SF
U9UTY ROOM y GENERATOR r .. " HOTEL 14NAGE ON
EWPR' FIE 62"JSF v" WALL. REFER TO
DETAIL I ON SHFFT tfi _.
OF NFOR DE'AS --
.. EPER.--LEG NOTA ENTRY -....
272 BE , ^--- SACLEAR CANOPY
. _.............. _ ... .....,.: _ .. _ " _ _ ......... .. _ _ .. ,., .. _ .... 04ERHcM HOTEL D9O. -OFF
ELECTP.E'AL GRAND
i
272 IF i BALLROOIA � k
1t5N BE
FLRECTL :, �
b I 272 SF
,
nRE;PumR t" , CONFERENCE
272SF CENTER D70F OFF
r
DOM, VfFR PdEFL'NCTION
PUMPE0F,ERS
4'S'F U' SF r` t5: Sf �-.. !
__.__ -__.. _., MAIN CCWFERENCE
1 CENTER ENTRY
OONFEREN:k'4C:lti'ER
CONFERENCE >K,;NAC.E O`r'kAtt. REFER TO
. k'EETK�G MEETIiG MEET3N4 WE=_TH, I
6! 4Y t T: 7, `:BEEF 1'95SF 1'CV ;,16S SF SUPPORT DML50N£NEET 160F 16
327 SF 725 SF FOR DETAILS
135�F
f
n_q
24 4' 'R-` SECC4:CARrC,y4FERENCE Cc'NTEREN'R'Y,...
zr
1.300 -Key Hotel Level 1
SCALE 1"=26'-O"
0 5' 10' 20' 60'
A DESIGN CONSULTANCY ANCY OF ARCADIS
0
t , ,
..- PA°YJ RftOhu
`'" ......_ OUTDOOR ACE
LOBBY !� 1 �-,
3zaR£t .
♦ 4 a
t /
-- HOTEL SLUNAGE ONYtALL. REFER
TO t£TAIL `.ONSPEET 1SOF 16 FCR
DETAILS
CCWNECTIGA7
Ec ONK-
T0
MASER TRAF.
Plan Notes:
1. These Plans are for conceptual purposes only. All building
plans require review and approval by Development Services.
2. All mechanical and electrical equipment, including air condition-
ing units, shall be designed, installed and operated to minimize
noise impact on surrounding property. All such equipment shall be
screen from public view.
3. In the case of on -premise beer, wine and mixed drink sales
A. Conditional use request for the sale, storage, and
on -premise consumption of alcoholic beverages (beer,
wine, and mixed beverages).
B. The entire site is the premise.
4. All speakers shall face away from any contiguous residential
zonig districts.
5. All Masonry shall follow City of Grapevine Appendix D - Zon-
ing -Ordinance No. 82-73, Section 54 - Masonry requirements.
6. All Signage shall follow City of Grapevine Appendix D - Zon-
ing -Ordinance No. 82-73, Section 60 - Sign Standards.
Facade Plan Notes:
7. All lighting shall be designed to reflect away from any adjacent
residential area.
8. Structures over 50'-0" are permitted on properties located east
of Fairway Drive.
NOT FOR CONSTRUCTION I
.k
x
�*
M1� {
RESTAURANT
UNEN STOR
TERRACE ,
63s SF
AUAM
1242'F
OmOC
i RESTAURANT
ISO CF
8 BAR
4314SF
EOIL LINEN
WALL .. � LOADING&
RECEF'+1NG
$43 SF
3`
� �.. ALCOH(X
^.; .. _. STOR.
114 BE
16. DRY STGR KFCHEN "
^YOFF ` OFF, AFF. ' „OFF. OFF. ' `OFF, DFF. •... :.-6FF. 4465E
/ ADpdIM& l96SF 165Sf ifi88F tOfl SF tCd SF .re SF I96SF 1985E
EMPLOYEE MEN ELEVLOSBY
SUPPORT CN.-FF0FPfi.F
EMPLOYEE .. 3,962 SF 142SF —._JAN. 423 SF 44's SF
' ENTRE ......._ ...._.,,_ ,:'" '.
Rp SF
" f iSkk.'N1Er
A. BANQUET MGP M}OtaEtt
s STORAGE1678E
& .,ASF �, 4235E
$ BOARD RGCA7 'E' •
461 SF r+" FRONT DESK
' BOARD WWI_ fi"'P-GRT
AV OfNiTROL .,_ t,' 461SF 655- FF
346SF BOARDROOM .>>
--- 5ER'ACE 576R 487 SF
CORRIDOR
¢ P 7,7334E
LUGS.
133 SF
U9UTY ROOM y GENERATOR r .. " HOTEL 14NAGE ON
EWPR' FIE 62"JSF v" WALL. REFER TO
DETAIL I ON SHFFT tfi _.
OF NFOR DE'AS --
.. EPER.--LEG NOTA ENTRY -....
272 BE , ^--- SACLEAR CANOPY
. _.............. _ ... .....,.: _ .. _ " _ _ ......... .. _ _ .. ,., .. _ .... 04ERHcM HOTEL D9O. -OFF
ELECTP.E'AL GRAND
i
272 IF i BALLROOIA � k
1t5N BE
FLRECTL :, �
b I 272 SF
,
nRE;PumR t" , CONFERENCE
272SF CENTER D70F OFF
r
DOM, VfFR PdEFL'NCTION
PUMPE0F,ERS
4'S'F U' SF r` t5: Sf �-.. !
__.__ -__.. _., MAIN CCWFERENCE
1 CENTER ENTRY
OONFEREN:k'4C:lti'ER
CONFERENCE >K,;NAC.E O`r'kAtt. REFER TO
. k'EETK�G MEETIiG MEET3N4 WE=_TH, I
6! 4Y t T: 7, `:BEEF 1'95SF 1'CV ;,16S SF SUPPORT DML50N£NEET 160F 16
327 SF 725 SF FOR DETAILS
135�F
f
n_q
24 4' 'R-` SECC4:CARrC,y4FERENCE Cc'NTEREN'R'Y,...
zr
1.300 -Key Hotel Level 1
SCALE 1"=26'-O"
0 5' 10' 20' 60'
A DESIGN CONSULTANCY ANCY OF ARCADIS
0
t , ,
..- PA°YJ RftOhu
`'" ......_ OUTDOOR ACE
LOBBY !� 1 �-,
3zaR£t .
♦ 4 a
t /
-- HOTEL SLUNAGE ONYtALL. REFER
TO t£TAIL `.ONSPEET 1SOF 16 FCR
DETAILS
CCWNECTIGA7
Ec ONK-
T0
MASER TRAF.
Plan Notes:
1. These Plans are for conceptual purposes only. All building
plans require review and approval by Development Services.
2. All mechanical and electrical equipment, including air condition-
ing units, shall be designed, installed and operated to minimize
noise impact on surrounding property. All such equipment shall be
screen from public view.
3. In the case of on -premise beer, wine and mixed drink sales
A. Conditional use request for the sale, storage, and
on -premise consumption of alcoholic beverages (beer,
wine, and mixed beverages).
B. The entire site is the premise.
4. All speakers shall face away from any contiguous residential
zonig districts.
5. All Masonry shall follow City of Grapevine Appendix D - Zon-
ing -Ordinance No. 82-73, Section 54 - Masonry requirements.
6. All Signage shall follow City of Grapevine Appendix D - Zon-
ing -Ordinance No. 82-73, Section 60 - Sign Standards.
Facade Plan Notes:
7. All lighting shall be designed to reflect away from any adjacent
residential area.
8. Structures over 50'-0" are permitted on properties located east
of Fairway Drive.
NOT FOR CONSTRUCTION I
Plan Notes:
1. These Plans are for conceptual purposes only. All building
plans require review and approval by Development Services.
2. All mechanical and electrical equipment, including air condition-
ing units, shall be designed, installed and operated to minimize
noise impact on surrounding property. All such equipment shall be
screen from public view.
3. In the case of on -premise beer, wine and mixed drink sales
A. Conditional use request for the sale, storage, and
on -premise consumption of alcoholic beverages (beer,
Vine, and mixed beverages).
B: The entire site is the premise.
4. All speakers shall face away from any contiguous residential
zonig districts.
5. All Masonry shall follow City of Grapevine Appendix D - Zon-
ing -Ordinance No. 82-73, Section 54 - Masonry requirements.
6. All Signage shall follow City of Grapevine Appendix D - Zon-
ing -Ordinance No. 82-73, Section 60 - Sign Standards.
Facade Plan Notes:.
7. All fighting shall be designed to reflect away from any adjacent
residential area.
B. Structures over 50'-0" are permitted on properties located east
of Fairway Drive,
NOT FOR CONSTRUCTION
f
(
Plan Notes;
1. These Plans are for conceptual purposes only. All building
plans require review and approval by Development Services.
2. All mechanical and electrical equipment, including air condition-
ing units, shall be designed, installed and operated to minimize
noise impact on surrounding property. All such equipment shall be
screen from public view.
3. In the case of on -premise beer, wine and mixed drink sales
A. Conditional use request for the sale, storage, and
on -premise consumption of alcoholic beverages (beer,
wine, and mixed beverages).
B. The entire site is the premise.
4. All speakers shall face away from any contiguous residential
zonig districts.
5. All Masonry shall follow City of Grapevine Appendix D - Zon-
ing -Ordinance No. 82-73, Section 54 - Masonry requirements.
6. All Signage shall follow City of Grapevine Appendix D - Zon-
ing -Ordinance No. 82-73, Section 60 - Sign Standards.
Facade Plan Notes:
7. All lighting shall be designed to reflect away from any adjacent
residential area.
8. Structures over 50'-0" are permitted on properties located east
of Fairway Drive.
NOT FOR CONSTRUCTION i
1.300-Key Hotel Level 131
SCALE 1"=20'-0"
0 5' 10' 20' 50'
,..
A DESIGN CONSULTANCY OF ARCAOI
PATIO
Plan Notes:
1. These Plans are for conceptual purposes only. All building
plans require review and approval by Development Services.
2. All mechanical and electrical equipment, including air condition-
ing units, shall be designed, installed and operated to minimize
noise impact on surrounding property. All such equipment shall be
screen from public view.
3. In the case of on -premise beer, wine and mixed drink sales
A. Conditional use request for the sale, storage, and
on -premise consumption of alcoholic beverages (beer,
wine, and mixed beverages).
B. The entire site is the premise.
4. All speakers shall face away from any contiguous residential
zonig districts.
5. All Masonry shall follow City of Grapevine Appendix D - Zon-
ing -Ordinance No. 82-73, Section 54 - Masonry requirements.
6. All Signage shall follow City of Grapevine Appendix D - Zon-
ing -Ordinance No. 82-73, Section 60 - Sign Standards,
Facade Pian Notes:
7. All lighting shall be designed to reflect away from any adjacent
residential area.
8. Structures over 50'-0. are permitted on properties located east
of Fairway Drive.
NOT FOR CONSTRUCTION I
Lv,
nit ott pts
'COV`r'fk:y(:s."tz:SR ..._ UPlIGH7MG AT
1.300 -Key Hotel Level 1 Lighting and Outdoor Speaker Plan
SCALE 1"=20'-0"
0 F-10' 20' so'
CALLISONRTKL
A DESWN C04SULFANICY €1F ARGA0,15
Aw \
O`f `
os' \
scogM.E AT
p.\ c=w'N'wP.
\\
KERN ,
SJFFET, TCP.
Oma\
DGWNLk.Sti' EGRM R
Plan Notes:
1. These Plans are for conceptual purposes only. All building
plans require review and approval by Development Services,
2. All mechanical and electrical equipment, including air condition-
ing units, shall be designed, installed and operated to minimize
noise impact on surrounding property. All such equipment shall be
screen from public view.
3. In the case of on -premise beer, wine and mixed drink sales
A. Conditional use request for the sale, storage, and
on -premise consumption of alcoholic beverages (beer,
wine, and mixed beverages).
B. The entire site is the premise,
4. All speakers shall face away from any contiguous residential
zonig districts.
5. All Masonry shall follow City of Grapevine Appendix D - Zon-
ing -Ordinance No. 82-73, Section 54 - Masonry requirements.
6. All Signage shall follow City of Grapevine Appendix D - Zon-
ing -Ordinance No. 82-73, Section 60 - Sign Standards.
Facade Plan Notes:
7. All lighting shall be designed to reflect away from any adjacent
residential area.
8. Structures over 50'-0" are permitted on properties located east
of Fairway Drive.
NOT FOR CONSTRUCTION
0
Plan Notes:
1. These Plans are for conceptual purposes only. All building k
plans require review and approval by Development Services.
2. All mechanical and electrical equipment, including air condition-
ing units, shall be designed, installed and operated to minimize
noise impact on surrounding property. At such equipment shall be
screen from public view.
3. In the case of on -premise beer, wine and mixed drink sales
A. Conditional use request for the sale, storage, and
on -premise consumption of alcoholic beverages (beer,
Vine, and mixed beverages).
B. The entire site is the premise,
4. All speakers shall face away from any contiguous residential
zonig districts.
5. All Masonry shall follow City of Grapevine Appendix D - Zon-
ing -Ordinance No. 82-73, Section 54 - Masonry requirements.
6. All Signage shall follow City of Grapevine Appendix D - Zon-
ing -Ordinance No. 82-73, Section 60 - Sign Standards,
Facade Plan Notes:
7. All lighting shall be designed to reflect away from any adjacent
residential area.
8. Structures over 50'-0" are permitted on properties located east
of Fairway Drive.
....-_'JOWNLM.:Mt OVER DOOR
C}
t,
'"I".
EXTER1ORWALI,
up 4 vkP.
CA
LO
DA
1.300 -Key Hotel Level 61 Lighting and Outdoor Speaker Plan DA
SCALE 1"=20'-0"
sr
0 5' 10' 20' 50'
A DESIGN CONSULTANCY OF ARCADIS
C
REFER TO DETAIL 4 ON SHEET 10 OF 20 FOR SIGNAGE DETAIL
1. HOTEL TOWER SOUTH ELEVATION
SCALE 1116"=1'A"
0 5' 10' 20' So'
TOP OF MECHANIC)
PARAPET.100'-0"
ROOF DECK:8r-O"
ti
LWV-0"
L7:68'-0"
v
L6:58'-0"
L5:48'4"
—c
L4:38'-0"
1.3:28'-0"
1-2:18'-0"
L1:W-V
SCALE 1/16"=1'-0'• �..,.�... ���„ ..�...
0 5' 10' 20' 50'
Facade Plan Notes:
MATERIALS AREA CALCULATION:
1. These Facade Plans are for conceptual purposes only. All building plans require review and approval by Development Services.
50970 ft'
53.3%
2. All mechanical and electrical equipment, includingair conditioningunits, shall be designed, installed and operated to minimize noise im-
9 P
A. Stucco Type A
30973 ft'
32A%
pact on surrounding property. All such equipment shall be screen from public view.
pact
B Stucco Type B
3. All Masonry shall follow City of Grapevine Appendix D - Zoning -Ordinance No. 82-73, Section 54 - Masonry requirements.
C Stone Type A
5973 ft'
6.2%
4. All Signage shall follow City of Grapevine Appendix D - Zoning -Ordinance No. 82-73, Section 60 - Sign Standards.
D Stone Type B
5297 112
5.5%
5. All lighting shall be designed to reflect away from any adjacent residential area.
E. Wood Panels
2377 ft2
2.5%
6. Structures over 50'-0" are permitted on properties located east of Fairway Drive.
Total Materials Area
95590 ft'
100%
v '
ORTKL
A DESIGN CONSULTANCY OF ARC WS
` 4 '
71� 6� ► ski {
4Jt'
NORTH
NOT FOR CONSTRUCTION
0
0
TOP OF MECHANIC
PARAPET:100'-0"
ROOF DECK -88'-O"
1.898'"0"
1.7:68%0"
L6:58' -O"
L5:48'-0"
L4:3W4"
L3:28'-0"
1.2:16'•0"
1.1:0'4"
3. HOTEL TOWER NORTH ELEVATION
SCALE 1/16"=1'-0"
0 5' 10' 20' so,
4. HOTEL TOWER EAST ELEVATION
SCALE 1116"=V-0"
0 5' 10' 20' 50'
Facade Plan Notes:
1. These Fagade Plans are for conceptual purposes only. All building plans require review and approval by Development Services.
2. All mechanical and electrical equipment, including air conditioning units, shall be designed, installed and operated to minimize noise im-
pact on surrounding property.. All such equipment shall be screen from public view,.
3. All Masonry shall follow City of Grapevine Appendix D - Zoning -Ordinance No. 82-73, Section 54 - Masonry requirements.
4. All Signage shall follow City of Grapevine Appendix D - Zoning -Ordinance No. 82-73, Section 60 - Sign Standards,
5. All lighting shall be designed to reflect away from any adjacent residential area.
6. Structures over 50'-0" are permitted on properties located east of Fairway Drive.
A DESIGN CON UILTANCY OF ARGADI
NOT FOR CONSTRUCTION
R
MATERIALS AREA CALCULATION:
' \\
lk
A. Stucco Type A
50970 f12
53.3%
4
B. Stucco Type B
30973 ft2
32.4%�
m """ `�
fes' '—'c�
C. Stone Type A
5973 ft'
6.2%
• ,
1 2
D. Stone Type B
5297 ft2
5.5%
t
®y t,
s
E. Wood Panels
2377 ft'
2.5%
Total Materials Area
95590 ft'
100°0
/
NORTH
NOT FOR CONSTRUCTION
R
NOT FOR CONSTRUCTION
WOOD PANELS
ALUMINUM STOREFRONT GLAZING SYSTEM
ALUMINUM STOREFRONT GLAZING SYSTEM
STUCCO TYPE B
STUCCOTYPEA
STUCCOTYPEA
STUCCO TYPE B
REFER TO DETAIL 3 ON SHEET
223.1'
10 OF 20 FOR SIGNAGE DETAIL
i
113'-0'
31'-10" 9'3" 6'-8'
150'-0'
25'x'
29'-1 19'-0' 8'-0' 56'-2"
TOP OF BALLROOM
PARAPET:31'-0"
—o
TOP OF PARAPET20'-0"
ROOF DECKAW-V TOP OF PARAPETI8'-0"
_
Tl
I
j
4,11
}
5. CONFERENCE CENTER SOUTH ELEVATION
6'CONFERENGE CENTER EAST ELEVATION
SCALE 1/16"=1'-0"
SCALE 1116"=1'-0"
0 5' 10 20' 50'
0 6' 10' 20' So'
TOP OF BALLROOM
19'.6' 9"
153'-4"
823"
—
PARAPET31'-0"
v
ROOF DECK:16'-0"
TOP OF PARAPETIB'-0"
TOP OF PARAPET.20'-0
STUCCO TYPE B
--
- ---v
1..
STUCCOTYPEA
RE
NO. '--- DESCRIPT
L1:W-0"
7. CONFERENCE CENTER SOUTH ELEVATION
CUP 300 ROO)
SCALE 1/16"=1'-0"
BUILDIN(
0 5' 10' 20' 50'
CASE NAME: s �rn uxc caosswos/nowss'Nce aom
CASE NUMBER�cVrs-as. Polo -m
-
LOC MON:Z Butt Pao WUar; L°T s, e— 1.
Jmum roxt caossHcs inortroa
,.,
Facade Plan Nates:
MATERIALS AREA CALCULATION:
MAYOR SECRETARY
S , \ DATE:
1
1. These Facade Plans are for conceptual purposes only. All building plans require
review and approval by Development Services,�
, \ 4
'
2. All mechanical and electrical equipment, including air conditioning units, shall be
designed, installed and operated to minimize noise im-
A. Stucco Type A 50970 ft2
t PANNING AND ZONING COMMISSION
53.3%
pact on surrounding property. All such equipment shall be screen from public view.
3. All Masonry shall follow City Grapevine Appendix D Zoning
B. Stucco Type B 30973 ft2
01~
32.4%
of - -Ordinance No. 82-73, Section 54 -Masonry requirements.
4. All Signage shall fallow City of Grapevine Appendix D - Zoning -Ordinance No. 82-73, Section 60 -Sign Standards.
C. Stone Type A 5973 ft'
YP
5297 ftz
i� fHAIRMAN
6.2 % 2 DATE:
'
HUITT-
5. All lighting shall be designed to reflect away from any adjacent residential area.
D. Stone Type B
z
5.5% � (�g
'® t "tt �2 sHEEr:_i¢_oF__tz
6. Structures over 50'-0" are permitted on properties located east of Fairway Drive.
E. Wood Panels 2377 ft
2,5%
�'� t
J
Neat-zon° ", lac.
Total Materials Area 95590 ft�
r G APPROVA DOES NOT AUTHORIZE ANY WORK
f 0O %
—t JZ I 3 �' j . IN CONFLICT WITH ANY CODES OR
500 W. 7th St. Ste. 300
Phone (817)335-3000
C L
--'s.� , ORDINANCES.
dtCONSULTANCY ' i
- —
NORTH
SCALE
DRAWN:
DEPARTMENT OF DEVELOPMENT SECES
SERVICES
AS SHOWP
CHECKED:
NOT FOR CONSTRUCTION
2" 13 7 -11' 275"
ROOF:47'dt"
v
PARAPEE38'"6"
ton " _
x '
IA�PE=
PARAPET:38'-6"
F Si
L6:25�
L8:35�
wa ,
r
1-7:30'"0"
11
1-3:10'
v
L6:2S-0"
L2:5"�Y;
4.f�r----�-
�C�I
L1:0'-0"
o
-
j $ �i STUCCO�PANELTYPEB
L5:20�
i
SCALE 1/16"=1'-0"
1-4:15'"0"
� �
L3:101-0"
rS"„tl P
i i x
L2:5'-0"
�...xr .K,,ui,
, ,;i' "tP ,xaa ii�� 1^,�:,i:"" ,,.irW'
STUCCO PANELTYPEASTUCCO
a
L1:0'-0"
r { V,
` PRECAST CONCRETE
STUCCO PANELTYPEA
8. GARAGE EAST ELEVATI,
,... ;i
SCALE 1/16"=1'-0"
x + r-' 1 r 1 ' i PAINTED PRECAST CONCRETE
`', n
0 5' 10' 20'
S0'
4T -T
ROOFAT'•0"
v
PARAPEE38'"6"
ton " _
�
IA�PE=
L7:3W-W'
1 3
r
L6:25�
Y
L5:20'4"
r
i
1-3:10'
r
L2:5"�Y;
r
L1:0'-0"
o
-
j $ �i STUCCO�PANELTYPEB
10. GARAGE WEST ELEVATION
SCALE 1/16"=1'-0"
0 5' 10' 20' S0'
'r ..."�
... ,•ir�',»•`�'.»`a'
rS"„tl P
t
12. PARKING ENTRY A SIGNAGE
SCALE 318"=1'-0"
0 V 2' 5' 10'
214'-3'
126'5"
I
24'-0' 20'-0' 3"
PAINTED PRECAST CONCRETE
Facade Plan Notes:
1, These Fagade Plans are for conceptual purposes only. All building plans require review and approval by Development Services.
2. All mechanical and electrical equipment, including air conditioning units, shall be designed, installed and operated to minimize noise im-
pact on surrounding property. All such equipment shall be screen from public view.
3. All Masonry shall follow City of Grapevine Appendix D - Zoning -Ordinance No. 82-73, Section 54 - Masonry requirements.
4. All Signage shall follow City of Grapevine Appendix D - Zoning -Ordinance No. 82-73, Section 60 - Sign Standards.
5. All lighting shall be designed to reflect away from any adjacent residential area.
6. Structures over 50'-0" are permitted on properties located east of Fairway Drive.
A DE tON CONSULTANCY OF A CADIS
16 - - A 11. GARAGE NORTH ELEVATION
REFER TO DETAIL 12 ON SHEET 16 OF 17 FOR SIGNAGE DETAIL SCALE 1116"=1'-0"
0 5' 10' 20' 50'
HALO LIT PIN MOUNTED BRUSHED ALUMINUM LETTERS
PAINTED PRECAST CONCRETE
—I J
r
i
NORTH Jh
NOT FOR CONSTRUCTION
6
z
VERTICAL CABLE TO SUPPORT PLANTING
ton " _
�
; t,,' , ,
PRECAST CONCRETE BARRIER WALL
PAINTED PRECAST CONCRETE
Facade Plan Notes:
1, These Fagade Plans are for conceptual purposes only. All building plans require review and approval by Development Services.
2. All mechanical and electrical equipment, including air conditioning units, shall be designed, installed and operated to minimize noise im-
pact on surrounding property. All such equipment shall be screen from public view.
3. All Masonry shall follow City of Grapevine Appendix D - Zoning -Ordinance No. 82-73, Section 54 - Masonry requirements.
4. All Signage shall follow City of Grapevine Appendix D - Zoning -Ordinance No. 82-73, Section 60 - Sign Standards.
5. All lighting shall be designed to reflect away from any adjacent residential area.
6. Structures over 50'-0" are permitted on properties located east of Fairway Drive.
A DE tON CONSULTANCY OF A CADIS
16 - - A 11. GARAGE NORTH ELEVATION
REFER TO DETAIL 12 ON SHEET 16 OF 17 FOR SIGNAGE DETAIL SCALE 1116"=1'-0"
0 5' 10' 20' 50'
HALO LIT PIN MOUNTED BRUSHED ALUMINUM LETTERS
PAINTED PRECAST CONCRETE
—I J
r
i
NORTH Jh
NOT FOR CONSTRUCTION
VERTICAL CABLE TO SUPPORT PLANTING
ton " _
�
; t,,' , ,
PRECAST CONCRETE BARRIER WALL
na CABLE RAILING
CABLE RAILING
`,I, i}i' }} $ i i PAINTED ALUMINUM METAL FRAME
� II:
r
r;';
-
j $ �i STUCCO�PANELTYPEB
±
PAINTEDALUMINUM METAL FRAME
'r ..."�
... ,•ir�',»•`�'.»`a'
rS"„tl P
i i x
PANEL TYPE B
�...xr .K,,ui,
, ,;i' "tP ,xaa ii�� 1^,�:,i:"" ,,.irW'
STUCCO PANELTYPEASTUCCO
a
r { V,
` PRECAST CONCRETE
STUCCO PANELTYPEA
�w
x °" '� r ��PAINTED
,... ;i
PAINTED PRECAST CONCRETE
x + r-' 1 r 1 ' i PAINTED PRECAST CONCRETE
`', n
x.,z. ',,• x^ Int
PAINTED PRECAST CONCRETE
.. �'
9' GARAGE SOUTH ELEVATION
REFER TO DETAIL 12 ON SHEET 16 OF 17 FOR SIGNAGE DETAIL
SCALE
0 5' 10' 20' 60'
-----------.... -------- -r`
1264'
24-0 1'-1" 13'-7" I5"
P6
&.3. 79'-T 1'
. 10'-6°
10,-10. "1,5"
f
'
�
- PAINTED PRECAST CONCRETE
PAINTED PRECAST CONCRETE
Facade Plan Notes:
1, These Fagade Plans are for conceptual purposes only. All building plans require review and approval by Development Services.
2. All mechanical and electrical equipment, including air conditioning units, shall be designed, installed and operated to minimize noise im-
pact on surrounding property. All such equipment shall be screen from public view.
3. All Masonry shall follow City of Grapevine Appendix D - Zoning -Ordinance No. 82-73, Section 54 - Masonry requirements.
4. All Signage shall follow City of Grapevine Appendix D - Zoning -Ordinance No. 82-73, Section 60 - Sign Standards.
5. All lighting shall be designed to reflect away from any adjacent residential area.
6. Structures over 50'-0" are permitted on properties located east of Fairway Drive.
A DE tON CONSULTANCY OF A CADIS
16 - - A 11. GARAGE NORTH ELEVATION
REFER TO DETAIL 12 ON SHEET 16 OF 17 FOR SIGNAGE DETAIL SCALE 1116"=1'-0"
0 5' 10' 20' 50'
HALO LIT PIN MOUNTED BRUSHED ALUMINUM LETTERS
PAINTED PRECAST CONCRETE
—I J
r
i
NORTH Jh
NOT FOR CONSTRUCTION
HALO LIT PIN MOUNTED BRUSHED
ALUMINUM LETTERS
1. HOTEL ENTRY SIGNAGE
SCALE 3/8"=1'-0"
0 V 2' 51 10,
HALO LIT PIN MOUNTED BRUSHED
ALUMINUM CHANNEL LETTER
HALO LIT PIN MOUNTED BRUSHED
ALUMINUM LETTERS
ANAISSANCU
CONFERENCE CENTER
3. CONFERENCE CENTER ENTRY SIGNAGE
SCALE 318"=I' -O"
0 V 2' 51 10,
STUCCO
HALO LIT PIN MOUNTED BRUSHED
ALUMINUM CHANNEL LETTER
HALO LIT PIN MOUNTED BRUSHED
ALUMINUM LETTERS
STONE
141"17 STUCCO.
STONE
2. HOTEL DRIVE WAY SIGNAGE
SCALE 3/8"=1'-0"
0 1' 2' 51 10'
BOTTOM OF THE LETTER IS 857' ABOVE THE GROUND
4. HOTEL TOWER SIGNAGE
SCALE 3/8"=1'-0"
0 V 2' 61 10,
NOT FOR CONSTRUCTION I
/Z01b I -LL--, -J-L-