Loading...
HomeMy WebLinkAboutPLBG2024-002546ADDRESS 3572 Twelve Oaks Ln. Grapevine, TX 76051 LEGAL Carriage Glen Addition Blk 1 Lot 6 A 6 S220 1 *06588018* PERMIT HOLDER Ron Tierney Tierney Plumbing (817) 251-9292 COLLABORATORS •Ron Tierney Tierney Plumbing (817) 251-9292 OWNERS •Hubbard Brad Alan INSPECTIONS 14 1. Plumbing Rough In 2. Plumbing Sewer 3. Plumbing Shower Pan 4. Plumbing Top Out 5. Plumbing Tub Seal 6. Plumbing Water Service 7. Plumbing Gas Service 8. Plumbing P-Trap 9. Plumbing Temp Gas 10. TCEQ Backflow Certification Submit 11. Backflow Device Inspection 12. Plumbing Customer Sevice Inspection 13. Plumbing Water Heater 14. Plumbing Final INFORMATION FIELDS **APPLICANT NAME (Individual)Ron Tierney **APPLICANT PHONE NUMBER 8172519292 VALUATION 1725 FEE TOTAL PAID DUE Plumbing Permit Fee {VALUE}$ 57.00 $ 57.00 $ 57.00 TOTALS $ 57.00 $ 57.00 $ 0.00 READ AND SIGN I HEREBY CERTIFY THAT THE FOREGOING IS CORRECT TO THE BEST OF MY KNOWLEDGE AND ALL WORK WILL BE PERFORMED ACCORDING TO THE DOCUMENTS APPROVED BY THE BUILDING DEPARTMENT AND IN COMPLIANCE WITH THE CITY OF GRAPEVINE CODES REGULATING CONSTRUCTION. IT IS UNDERSTOOD THAT THE ISSUANCE OF THIS PERMIT DOES NOT GRANT OR AUTHORIZE ANY VIOLATION OF ANY CODE OR ORDINANCE OF THE CITY OF GRAPEVINE. I FURTHER CERTIFY THAT ALL WORK THAT IS REQUIRED TO COMPLY WITH ANY FEDERAL, STATE, AND / OR LOCAL LAW REGARDING ENERGY CONSERVATION WILL BE PERFORMED IN ACCORDANCE WITH THOSE LAWS, AND THAT VERIFICATION OF ENERGY CODE COMPLIANCE SHALL BE SUBMITTED TO THE CITY UPON REQUEST. July 19, 2024 Signature Date City of Grapevine PO Box 95104 Grapevine, Texas 76099 817) 410-3166 Plumbing Permit {VALUE} Project # 24-002546 Project Description: Replace double check valve at the curb to irrigation Issued on: 07/19/2024 at 10:50 AM MYGOV.US 24-002546, 07/19/2024 at 10:50 AM Issued by: Courtney Cogburn Page 1/2 Texas Commission on Environmental Quality BACKFLOW PREVENTION ASSEMBLY TEST AND MAINTENANCE REPORT The followin - fbrm must be com, leted for ewh assembh'tested. A signed nd dated orkirad must be submitted to the u wata supjAjer for recordkeel4n, W1:10SM plic i NAME OF PWS: Grapevine f,WS ID#: zz=:i PIWS- MXIINGADDRESS: PWS CONTACT PERSON: 13aq"oW tor ADDRESS OF SERVICE, SFD/ 3572 Twelve Oaks Ln The backflow prevention assembly detailed below has been tested and maintained as required by commission regulations and is certified to be oble parameters. OF BACIUWW PREVENTION ASSEMBLY (BPA�: Reduced Pressure Principle (RPBA) Reduced Pressure PrinFiple-Detector (RPBA-D) Type ]g �[31 srt Double Check Valve (DCVA) Double Cbeck-Detector (DCVA-D) Type H ID jo j Spill -Resistant Pressure Vacuum Breaker (SVB) Pressure Vacuum Breaker (PVB) Mani main: Bypass:; Size: 1"n: Bypass: Model Number: Main- Bypass BPA Location: i Main: 77 S�al. Numbe ass i BPA Serves- Byp PERMIT NumBER: 24-002546 Reason for test: i New JX' Existing -0' Replacement Old Model/Serial #I Is the assembly installed in accordance with manufacturer recommendations and/or local codes 14 IYes No Is the assembly installed on a non -potable water supply (auxiliary)? , 0 1�'es j[Z No TEST RMJMT:� Type 19 Reduced Pressure Principle Assembly (RPBA) Assembly PVB & SVB PAS� DCVA Relief Valve Bypass Check Air Inlet Check �Valve I a Ch��k 2nd Chec�*** FAIL 0 psid 11 Held at 'i Ipsid Leaked p,WTHeld at 21 check. numeric reading, re atured for pgApniv Potable: _D�R;;n�ai pressure gauge used: Nop-Potable: SN: 111306 61-02- 41 MakelModel: Ljq 31 Date tested for pnMac,� Remwks- Company Name: Licensed Tester Name .01 Accuracy Backfiow Brian Cox (PrintlType), Company Address: Po Box 6832 Licensed Tester Name (Signature): McKinney, TX 75071 Company one It. I SPAT License # BPDI�T77066- 972-699-7156 License Exg,iration Date: 02-23-25 The above is cerdfied to be true at the thne of tesfin& TEST RECORDS MUST BE KEPT FOR AT LEAST THREE YEARS [30 TAC §290.46(B)j ** USE ONLY MANUFACTURER'S REPLACEMENT PARTS TCEQ-20700 (Revision 04-04-2019) Page I of 1