Loading...
HomeMy WebLinkAboutPLBG2024-002752ADDRESS 1855 Cimarron Trl. Grapevine, TX 76051 LEGAL Pallaggios Estates Blk 1 Lot 3A PERMIT HOLDER Dillon Patterson SWAT PLUMBING (817) 244-4370 COLLABORATORS •Dillon Patterson SWAT PLUMBING (817) 244-4370 OWNERS •Johnson, James F INSPECTIONS 2 1. Plumbing Water Service 2. Plumbing Final INFORMATION FIELDS **APPLICANT NAME (Individual)DILLON PATTERSON **APPLICANT PHONE NUMBER 817-244-4370 VALUATION 3500 Square Footage 50 FEE TOTAL PAID DUE Plumbing Miscellaneous Fee $ 37.00 $ 37.00 $ 37.00 TOTALS $ 37.00 $ 37.00 $ 0.00 READ AND SIGN I HEREBY CERTIFY THAT THE FOREGOING IS CORRECT TO THE BEST OF MY KNOWLEDGE AND ALL WORK WILL BE PERFORMED ACCORDING TO THE DOCUMENTS APPROVED BY THE BUILDING DEPARTMENT AND IN COMPLIANCE WITH THE CITY OF GRAPEVINE CODES REGULATING CONSTRUCTION. IT IS UNDERSTOOD THAT THE ISSUANCE OF THIS PERMIT DOES NOT GRANT OR AUTHORIZE ANY VIOLATION OF ANY CODE OR ORDINANCE OF THE CITY OF GRAPEVINE. I FURTHER CERTIFY THAT ALL WORK THAT IS REQUIRED TO COMPLY WITH ANY FEDERAL, STATE, AND / OR LOCAL LAW REGARDING ENERGY CONSERVATION WILL BE PERFORMED IN ACCORDANCE WITH THOSE LAWS, AND THAT VERIFICATION OF ENERGY CODE COMPLIANCE SHALL BE SUBMITTED TO THE CITY UPON REQUEST. August 02, 2024 Signature Date City of Grapevine PO Box 95104 Grapevine, Texas 76099 817) 410-3166 Plumbing Permit - MISC Project # 24-002752 Project Description: WATER LINE REPLACEMENT TO REPAIR THE LEAK ON THE MAIN WATER LINE Issued on: 08/02/2024 at 1:20 PM MYGOV.US 24-002752, 08/02/2024 at 1:20 PM Issued by: Connie Cook Page 1/2 Texas Commission on Environmental Qaqjkify BACKFLOW PREVENTION ASSEMBLY TEST AND JWAM1,WNAjNCE REpORT The fellowin,- form must be completed for each assembly tested. A si-_,ied and dated o6einal must be submitted to the jiublic %Vatff sulylier for reer, I rdkeerin, *i,,wi Wes: �__NAME OF PWS: ne ­ - __ __ _ _ _I Grapevi PWS ID#: PWS MAIL-ING ADDRESS: PW_S CONTACT PERSOM Backfiow Coordinator ADDRESS OF SERVICE.: SFD/ 1855 Cyrnarron Trail ___Qhloe1 SWAT PI/ 682-200-39014 The backflow prevention assembly detailed below has been tested and mairtained as required by commission regulations and is certified to be operating within acceptable pwameters. TYPE OF BACKFLOW PREVENTION ASSEP,1P:LY'(BPA),- Reduced Pressure Principle (RPBA) Reduced Pressure Prine : o iple-Detector (RPBA-D) Type H : 'i X; Double Check Valve (DCVA) Double Check-Delector (DCVO,-D) Type H2O Pressure Vacuum Breaker (PVB) Spill -Resistant Pressure Vacuum breaker (SYB) M_ain:3/4" Manufacturer: Main: FebCo Bypass-, Size: Bypass: I Model Number: Main: 850 RypassJ: EPA Location: Lett Side Vroe ety-dt &te Serial Number: Main. HD56090 Bypass; TiiPk_Ser_veS: 1 Irrigation PERMIT NUMBER: 24- 027 Reason for test: New Existing 0: Replacement E1 Old Model/Serial # a, Is the assembly installed i accordance with manufacturer recommendations and/or local codes? es No Is the assembly installed on, a non -potable water supply (auxWary)? eyes TEST RESULT Typa Il Reduced Pressure Principle Assembly (RPBA) Assembly PVB & SVB 7- PASg DCVA Relief Valve Bypass Check Airinlet Check 'Valve FAIL 0 1 Check 21 Check' Initial Test 7Heldatl" �si d Held ZZ;DTpsid Opened at Held at paid Opened at;.. j psid Held al dosed Ti Closed Tlght,0 11 Did no" OPP ,Date:, Tight Closed Tight psid Time 'Leaked Did not Lcakr Did it fully o Leaked (;)ygxakcd pen d open Q "M19 salt;.„. R a!" Date7., Tim e .Bypass: Held at psid Held at psid Glassed TightClosed Tight 2,d check: numeric readim_� [_ 4� ]�, rt Differential pressure gaug ge used- MakeM90ej:_ Midwest We�t I Remarks: 1 kYes lu /No U) Opened at;_._; Held at.! psid Opened at psid held at psid Closed Mid Tight �11 b, ota (astable:N,011 211 5 Date tested for taco brad _L7_ Ll I _01 -2023 i, L_,ompany Name: .01 Accuracy Backflow Licensed Tester Name Robert MacCloskey (Print/Tyre): Company Address: Po Box 6832 Licensed TesterName (Sigaature): McKinney, TX 75071 Company Phone W: 972-699-7156 SPAT License i BP0021622 License Exeiratioq D-ae, 1-11-22-2025 The above is certified to be true at the time of testing. TEST RECORDS MUST BE KEF`T FOR AT LEAST THREE YEARS [30 TAC §290,46(B)] [ISE ONLY MANUFACTURER'S REPLACEMENT PARTS TCEQ-20700 (Revision 04-04-2019) Page 1 of 1,