HomeMy WebLinkAboutSFRA2024-003346ADDRESS
301 Banyan Dr.
Grapevine, TX 76051
LEGAL
Banyan Place Blk 3 Lot
1r
A 1R
S220 3
*06359590*
PERMIT HOLDER
Teresa Wise
Olshan Foundation Repa
ir
(972) 238-1600
COLLABORATORS
•Teresa Wise
Olshan Foundation
Repair
(972) 238-1600
OWNERS
•Miller, Keith
INSPECTIONS 1
1. Building Final
INFORMATION FIELDS
**APPLICANT NAME (Individual)Teresa Wise
**APPLICANT PHONE NUMBER 682-333-8879
VALUATION 21000
* CONSTRUCTION TYPE VB
* OCCUPANCY GROUP R-3
DOCUMENTS - MISC 01 301 Banyan Drive - Permit
Application.pdf
DOCUMENTS - MISC 02 301 Banyan Drive - Olshan DA Rev.pdf
DOCUMENTS - MISC 03 REVISED PLANS 9-19-24.pdf
DOCUMENTS - MISC 04 REVISED APPLICATION.pdf
* ZONING DISTRICT R-5.0
FEE TOTAL PAID DUE
Building Permit Fee, ($150.00
Flat Fee) Simple Alteration $ 150.00 $ 150.00 $ 150.00
TOTALS $ 150.00 $ 150.00 $ 0.00
READ AND SIGN
I HEREBY CERTIFY THAT THE FOREGOING IS CORRECT TO THE BEST OF
MY KNOWLEDGE AND ALL WORK WILL BE PERFORMED ACCORDING TO
THE DOCUMENTS APPROVED BY THE BUILDING DEPARTMENT AND IN
COMPLIANCE WITH THE CITY OF GRAPEVINE ORDINANCE REGULATING
CONSTRUCTION. IT IS UNDERSTOOD THAT THE ISSUANCE OF THIS PERMIT
DOES NOT GRANT OR AUTHORIZE ANY VIOLATION OF ANY CODE OR
ORDINANCE OF THE CITY OF GRAPEVINE.
I FURTHERMORE UNDERSTAND THAT PLANS AND SPECIFICATIONS ARE
NOT REVIEWED FOR HANDICAPPED ACCESSIBILITY BY THE CITY AND THAT
THE DESIGN PROFESSIONAL / OWNER IS RESPONSIBLE FOR OBTAINING
SUCH APPROVAL FROM THE APPROPRIATE STATE AND OR FEDERAL
AGENCY(S).
City of Grapevine
PO Box 95104
Grapevine, Texas 76099
817) 410-3166
Building - Residential
Alteration
Project # 24-003346
Project Description: Foundation Repair-Install 25 Pilings and
adjust 7 existing pilings
Issued on: 09/23/2024 at 3:34 PM
MYGOV.US 24-003346, 09/23/2024 at 3:34 PM Issued by: Connie Cook
Page 1/2
eptember 12,2024
01shan Foundation Solutions
1614 Bluebank Road
Dallas, Texas 75229
Subject: Review for Permit Letter
Re: 301 Banyan Drive, Grapevine, Texas 76051
Dunaway I BEG' has reviewed the sketch and the foundation repair system
proposed for the subject location. In our opinion, the proposed foundation repair
and adjustments to the existing pilings should minimize the foundation settlement
at the subject location provided proper installation techniques are used which
includes all piles to be installed and driven to the point of refusal. In addition, the
installation is to be per the manufacturer's recommendations, specifications for
pre -cast concrete Cable LockTM pilings FPA-SC-08 latest edition which can be
found at w-,,vw I ou n{] (1 tic) r � I t(:) i industry standards, proper
foundation maintenance is performed and in accordance with 2021 IRC. A
foundation maintenance program can be obtained at the Foundation
Performance Association website.
The areas that are represented by cross -hatching on the attached sketch are
the areas, in our opinion, that will be affected by the proposed foundation repair
system, provided the foundation system is of acceptable strength. If the actual
strength of the foundation system is found to be inadequate to support the
spacing of the piles as shown on the attached sketch, then additional piles may
be required to support the foundation.
Dunaway I BEC appreciates being of service. If YOU have any questions or
require additional information, please contact the undersigned.
Regards,
11-1114KI, _/1
Megan McLernore, PE
Dunaway I BEC
REVISIONS RECEIVED 9�20!2024
1; 24-003346
301 BANYAN DRIVE
FOUNDATION REPAIR
Z� pi
1.. .. .. .. .. . ...
3200 MDrive, ve, Suite 440
'�DUNAWAYIBEC Houston, Texas 77042
P: 832-240-3771
F: 832-240-2724
TBPE #F-1 i 14
vvw,Ii.dunw,ay.com
301 Banyan Drive, Grapevine, Texas 76051
8,000 PSI
Heavy Outy
Inte0o(king
Steel Segments go
ot Nliwl Va"V
I
I ------ - _ --- ---------
Piles are to be installed and
driven to the point of refusal
m
III I III III I I II � I II II �
m
SANDRA MILLER
BANYAN301 DRIVE
GRAPEVINE,
m
5
4
f lllllll 111114 3
2
i
<6
ADJ
ADJ
ADJ
11IIlIl ADJ
#II im1,II 11
DUNN 'AY BEC
324 01crestOwe Sute440 Houston, Teas 77042 *bUNAWAyjBEEPh 832-240-37791 Fa, 0..32-240-2724
TREE REGIS #, F-1114
NOTES UNLESS OTHERWISE SPECIFIED
PILES SHOULD BE INSTALLED TO REFUSAL WHICH, IS DEFINED AS WHEN THE EXISTING
FOUNDATION START TO HAVE UPLIFT FROM THE DRIVING FORCE EXERTED ON THE PILE
EXTERIOR PILINGS SHOULD BE AT A SPACING NOT GREATER THAN 8 FEET CENTER TO
CENTER ON ONE STORY HOMES AND NOT GREATER THAN fir FEET ON TWO STORY HOMES
ELEVATION READINGS SHALL BE TAKEN BEFORE AND AFTER THE FOUNDATION LIFT
INDICATES AREA AFFECTED BY NEW PILINGS
ELEVATIONS HAVE BEEN ADJUSTED FOR VARIATIONS dN FLOOR COVERINGS
ADJUST EXISTING PILINGS AS REQUIRED, IF ANY
LEGEND
♦ PROPOSED PIER 0 BUILDERS PIER X PREVIOUS WORK