Loading...
The URL can be used to link to this page
Your browser does not support the video tag.
Home
My WebLink
About
SFRA2024-004006
RECEIVED: 11/4/2024 24-004006 DATE OF ISSUANCE: 2621 KIMBERLY DRIVE SOLAR PANEL INSTALLATION PERMIT #: I IJ BUILDING PERMIT APPLICAT.1,0N JOB ADDRESS: 2621 Kimberly Dr. LOT: BLOCK: BUILDING CONTRACTOR (companv name): Southern Solar LLC CURRENT mAjj_,x 5000 Overton Plaza STE 200 CITYSTATE/zip: Fort Worth, Tx 761 Ot PROPERTY OWNER: Jim Hodgson CURRENTMAILING ADDRESS: 2621 Kimberly Dr. CITY/,STATE/ZIP: Grapevinve, Tx 76051 1 A MM. FIRE SPRINKLERED? YES WHAT TRADES WILL BE NEEDED? , :,, �, �::: , — : � a ELECTRIC X PLUMBING DESCRIPTION OF WORK TO BE DONE: Installation of PV Solar System USE OF BUILDING OR STRUCTURE: Single Family Residence NAME OF BUSINESS: ME Total Square Footage tinder roof. 189-14 Square Footage of alteration/addition: 189.14 C1 I hereby certify that plans have been reviewed and the building will be inspected by a certified energy code inspector in accordance with State Law. Plan review and inspection documentation shall be made available to the Building Department (required for new buildint-Fs, alterations and additions) Ll I hereby certify that plans have been submitted to the `Texas Department of Licensing and Regulation for Accessibility Review. Control Number: (Not required for I & 2 family dwellings) L3 I hereby certify that an asbestos survey has been conducted for this structure in accordance with the regulatory requirements ofthe `Texas Department of Health. (REQUIRED FOR DEMOLITIONS, ADDITIONS AND OR ALTERATI( NTO COMMERCIAL AND PUBLIC BUILDINGS) I hereby certity that the foregoing is correct to the best of my knowledge and all work will be perlortnedaccording to The docinnents approved by the Building Department and in compliance with the City Of Grapevine Ordinance regulating construction. It is understood that the issuance of this permit does not grant or authorize any violation of any code or ordinance of the City Of Grapevine. I 14IRTHERNIORF UNDERSTAND THAT PLANS AND SPECIFICATIONS ARE NOT REVIEWED FOR HANDICAPPED AND THAT THE DESIGN PROFESSIONA L/OWNER IS RESPONSIBLE FOR OBTAINING SUCH APPRON'AL FRONITHE APPROPRIATE STATE AND OR FEDERAL AGFN('Y(Si, PRINT NAME: Hamid Moradi SIGNATURE PHONE#,. 817-751-8911 EMAIL: projectmanager@southernsolartx.com Q CHECK BOX IF PREFERRED TO BE CONTACTED BY E-MAIL THE FOLLOWING IS TO BE COMPLETED BY THE BUILDING INSPECTION DEPARTMENT FCon,struction Type. VT Permit Valuation: $ Setbacks Approval to ISSLIC I occupancy Group. 9 - 3 Fire Sprinkler: YES— NO Division: Zoning: PVD R- 7. Building Depth: Building Width: Occupancy Load: -Rlrease Trap Plan Review Approval: Date: //- 12 Site Plan Approval: Date: Fire Department: Date - Public Works Department Date: Health Department: Date: Approved for Permit: Date: I -Lot Drainage Submitted: Approved: Front: Electrical j Left: Plumbing Rear: Mechanical Right: Hood Building Permit Fee: Plan Review Fee: Lot Drainage Fee: Sewer Availability Rate: Water Availability Rate: Total Fees: Total Amount Due: PO BOX 95104, GRAPEWW--� 7 X 760119 MI 7; 410-3165 OYORMSOSPEAM11APPLICATIONS ADDRESS 2621 Kimberly Dr. Grapevine, TX 76051 LEGAL Silvercrest I Blk 1 Lot 11 S *06318959* PERMIT HOLDER Hamid Moradi Southern Solar (817) 751-8911 COLLABORATORS •Hamid Moradi Southern Solar (817) 751-8911 OWNERS •Hodgson, James R INSPECTIONS 1 1. Building Final INFORMATION FIELDS **APPLICANT NAME (Individual)Hamid Moradi **APPLICANT PHONE NUMBER 8177518911 APPLICANT E-MAIL VALUATION 32400 * CONSTRUCTION TYPE VB * OCCUPANCY GROUP R-3 DOCUMENTS - MISC 01 APPLICATION.pdf DOCUMENTS - MISC 02 CONSTRUCTION PLANS.pdf, ENGINEERED LETTER.pdf * ZONING DISTRICT R-7.5 APPROVED TO ISSUE ELECTRIC YES FEE TOTAL PAID DUE Building Permit Fee, ($150.00 Flat Fee) Simple Alteration $ 150.00 $ 150.00 $ 150.00 TOTALS $ 150.00 $ 150.00 $ 0.00 READ AND SIGN I HEREBY CERTIFY THAT THE FOREGOING IS CORRECT TO THE BEST OF MY KNOWLEDGE AND ALL WORK WILL BE PERFORMED ACCORDING TO THE DOCUMENTS APPROVED BY THE BUILDING DEPARTMENT AND IN COMPLIANCE WITH THE CITY OF GRAPEVINE ORDINANCE REGULATING CONSTRUCTION. IT IS UNDERSTOOD THAT THE ISSUANCE OF THIS PERMIT DOES NOT GRANT OR AUTHORIZE ANY VIOLATION OF ANY CODE OR ORDINANCE OF THE CITY OF GRAPEVINE. I FURTHERMORE UNDERSTAND THAT PLANS AND SPECIFICATIONS ARE NOT REVIEWED FOR HANDICAPPED ACCESSIBILITY BY THE CITY AND THAT THE DESIGN PROFESSIONAL / OWNER IS RESPONSIBLE FOR OBTAINING SUCH APPROVAL FROM THE APPROPRIATE STATE AND OR FEDERAL AGENCY(S). City of Grapevine PO Box 95104 Grapevine, Texas 76099 817) 410-3166 Building - Residential Alteration Project # 24-004006 Project Description: Installation of PV Solar System [ELECTRONIC REVIEW] Issued on: 11/14/2024 at 10:25 AM MYGOV.US 24-004006, 11/14/2024 at 10:25 AM Issued by: Connie Cook Page 1/2 November 14, 2024 Signature Date City of Grapevine Building - Residential Alteration Project # 24-004006 NOTICES 1) ALL work must be done in compliance with the 2021 INTERNATIONAL BUILDING CODE. **ALL work ISSUED prior to January 1, 2024, must be done in compliance with the 2006 INTERNATIONAL BUILDING CODE. 2) City Approved Stamped Plans must be on-site for ALL INSPECTIONS. 3) Project address must be clearly posted at the job site. NOTES > 24 HOUR INSPECTION NUMBER METRO (817) 410-3010, CUT OFF TIME FOR A.M. INSPECTION IS 7:30 A.M. --- CUT OFF TIME FOR P.M. INSPECTION IS 12:30 P.M. > PERMIT ISSUED IN ACCORDANCE WITH APPLICATION ON FILE IN THIS OFFICE. THIS PERMIT SHALL EXPIRE IF WORK IS NOT COMMENCED WITHIN (180 DAYS) OF ISSUANCE OR IF WORK IS SUSPENDED OR ABANDONED FOR A PERIOD OF (180 DAYS). THE ISSUANCE OR GRANTING OF THIS PERMIT AND / OR APPROVAL OF PLANS, SPECIFICATIONS AND COMPUTATIONS SHALL NOT BE CONSTRUED TO BE A PERMIT FOR, OR AN APPROVAL OF, ANY VIOLATION OF ANY OF THE PROVISIONS OF THE CODES AND ORDINANCES OF THE CITY OF GRAPEVINE. THE ISSUANCE OF A PERMIT BASED ON PLANS, SPECIFICATIONS, AND OTHER DATA SHALL NOT PREVENT THE BUILDING DEPARTMENT FROM THEREAFTER REQUIRING THE CORRECTION OF ERRORS IN SAID PLANS, SPECIFICATIONS, AND OTHER OR REQUIRING CORRECTIONS OF THE CONSTRUCTION ITSELF. MYGOV.US 24-004006, 11/14/2024 at 10:25 AM Issued by: Connie Cook Page 2/2 COPE OF WORK TO INSTALL A ROOF MOUNTED SOLAR PHOTOVOLTAIC SYSTEM AT THE OWNER RESIDENCE LOCATED AT 2621 KIMBERLY DR. GRAPEVINE, TX 76051, USA THE POWER GENERATED BY THE PV SYSTEM WILL BE INTERCONNECTED WITH THE UTILITY GRID THROUGH THE EXISTING ELECTRICAL SERVICE EQUIPMENT. THE PV SYSTEM DOES NOT INCLUDE STORAGE BATTERIES, EOUIPMENTSUMMARY 18 LONG[ LR6.54HABB-400M MODULES j 118 ENPHASE I08PLUS-72.2-US (240V) MICROINVERTERS GENERAL NOTES THESE CONSTRUCTION DOCUMENTS HAVE BEEN BASED ON FIELD INSPECTIONS AND OTHER INFORMATION AVAILABLE AT THE TIME. ACTUAL FIELD CONDITIONS MAY REQUIRE MODIFICATIONS CONTRACTOR SHALL FURNISH ALL LABOR. MATERIAL, EQUIPMENT. TOOLS, OBTAIN ALL PERMITS, LICENSES AND PAY ALL REQUIRED FEES AND COMPLETE INSTALLATION. « CONTRACTOR SHALL OBTAIN BULDING PERMIT NO WORK TO START UNLESS BUILDING PERMIT IS PROPERLY DISPLAYED, • ALL WORKMANSHIP AND MATERIALS SHALL BE OF FIRST QUALITY AND IN COMPLIANCE WITH THE REQUIREMENTS OF THE NATIONAL BUILDING CODE, THE DEPARTMENT OF ENVIRONMENTAL PROTECTION AND ALL PERTINENT AGENCIES. • IT IS ESSENTIAL THAT ALL WORK PROCEED WITH THE MAXIMUM COOPERATION OF ALL PARTIES AND WITH MINIMUM INTERFERENCE TO THE OCCUPANTS WITHIN THE BUILDING. THE OWNER'S DIRECTIONS IN THIS REGARD SHALL BE FULLY COMPLIED WITH. « THE CONTRACTOR SHALL PERFORM THE WORK IN STRICT CONFORMANCE WITH THE LOCAL LAWS. REGULATIONS AND THE NATIONAL ELECTRIC CODE. THE CONTRACTOR SHALL OBTAIN ALL PERMITS, APPROVALS, AFFIDAVITS, CERTIFICATIONS, ETC. AND PAY ALL FEES AS REQUIRED BY THE LOCAL AUTHORITIES. « CONTRACTORS SHALL OBTAIN FIRE CERTIF. UPON COMPLETION OF WORK. ELECTRICAL NOTES ALL EQUIPMENT TO BE LISTED BY UL OR OTHER NRTL, AND LABELED FOR ITS APPLICATION, ALL CONDUCTORS SHALL BE COPPER, RATED FOR 600 V AND 90 DEGREE C WET ENVIRONMENT. • WIRING. CONDUIT, AND RACEWAYS MOUNTED ON ROOFTOPS SHALL BE ROUTED DIRECTLY TO, AND LOCATED AS CLOSE AS POSSIBLE TO THE NEAREST RIDGE, HIP, OR VALLEY. WORKING CLEARANCES AROUND ALL NEW AND EXISTING ELECTRICAL EQUIPMENT SHALL COMPLY WITH NEC 110.26 WHERE SIZES OF JUNCTION BOXES, RACEWAYS, AND CONDUITS ARE NOT SPECIFIED, THE CONTRACTOR SHALL SIZE THEM ACCORDINGLY, ALL WIRE TERMINATIONS SHALL BE APPROPRIATELY LABELED AND READILY VISIBLE. » MODULE GROUNDING CLIPS TO BE INSTALLED BETWEEN MODULE FRAME AND MODULE SUPPORT RAIL, PER THE GROUNDING CLIP MANUFACTURERS INSTRUCTION. MODULE SUPPORT RAIL SHALL BE BONDED TO THE MODULE PRONG TRUONG 144185 GOVERNING CODES 2021 INTERNATIONAL BUILDING CODE 2021 INTERNATIONAL RESIDENTIAL CODE 2021 INTERNATIONAL FIRE CODE 2020 NATIONAL ELECTRICAL CODE •AHJ NAME: GRAPEVINE CITY WIRING AND CONDUIT NOTES ALL CONDUIT SIZES AND TYPES SHALL BE LISTED FOR ITS PURPOSE AND APPROVAL FOR THE SITE APPLICATIONS ALL PV CABLES AND HOMERUN WIRES BE #10AWG'USE-2. PV WIRE, OR PROPRIETARY SOLAR CABLING SPECIFIED BY MFR, OR EQUIVALENT; ROUTED TO SOURCE CIRCUIT COMBINER BOXES AS REQUIRED ALL PV DC CONDUCTORS IN CONDUIT EXPOSED TO SUNLIGHT SHALL BE DEBATED ACCORDING TO AS PER LATEST NEC CODE. EXPOSED ROOF PV DC CONDUCTORS SHALL BE USE-2.90"C RATED. WET AND UV RESISTANT, AND UL LISTED RATED FOR 60OV, UV RATED SPIRAL WRAP SHALL BE USED TO PROTECT WIRE FROM SHARP EDGES PHASE AND NEUTRAL CONDUCTORS SHALL BE DUAL RATED THHNtTHWN-2 INSULATED: 90"C RATED, WET AND UV RESISTANT, RATED FOR 10OOV AS PER APPLICABLE NEC 4-WIRE DELTA CONNECTED SYSTEMS HAVE THE PHASE WITH THE HIGHER VOLTAGE TO GROUND MARKED ORANGE OR IDENTIFIED BY OTHER EFFECTIVE MEANS ALL SOURCE CIRCUITS SHALL HAVE INDIVIDUAL SOURCE CIRCUIT PROTECTION VOLTAGE DROP LIMITED TO 2% AC CONDUCTORS >4AWG COLOR CODED OR MARKED PHASE A OR Ll- BLACK. PHASE B OR L2- RED, PHASE C OR L3- BLUE, NEUTRAL.- WHITEIGRAY SEPERATE PLAIRNG. Ms CHANICAL. LECTRI.A_ "D SIC s PERM`q 18"AL BE REECUIRED l :l1 Date Signed. 10,30.24 Firm Number: F-23402 F'R,)JECI SITE F147'gVCI i'a3t;U:kil the CII-b ald Grarv,'a' CSC ' VICINITY MAP 'CALF NTN ALL CHANGES III APPROVAL OF REVISED PLANS cl{IS {:1ii,lC 1tEtLr',fFt� F,aR rJCI� 3 (;! 1_TtgP� L l f ryl f-- SYSTEM RATING i, 200 kV\Vr. kWAC PV1 PV2 PV'3 PV4 PVE_PVc PV7 PV8 PV9-PV10 PV11-PV1t3 PF QTOVOLTAIC SYSTEM FIRE CLASSIFICATION ST NG I LISTING N ACCORDANCE WITH UL 1703 STANDARD. SHEETINDEX COVER PAGE SITE PLAN ROOF PLAN STRING LAYOUT R BOM ATTACHMENT DETAILS ELE:;TRICAL LINE & CALCS SPECIFIDAT IONS & NOTES S IGNAGE EQUIPMENT SPECIFICATIONS HOUSE PHOTO $CALC NIS CONSTRUCTION MOORS 7:00 AA, - 7:00 RM, MONDAY . SATURDAY ONLY NO WORK PIMROTTED ON SUNDAY RECEIVED:A 1 1 124-004006 ,2621 KIMBERLY DRIVE AP PANEL a a tee,: VANTAGEE POINT I910 PAC FI M AVE SU TE 9250, DALLA5, TX 75201, USA PHrr {Blti19?453?5 $Y:>TEM INFO, EIS LONGI LRi+ ;.1NAE'C3--tOC:Atl (1el CNPHA9E ItjBPLl: "2-..-US 124W,, DC SYS TEM'JIZE 7400VDC AC SY$ rE M SIZE 5 4C5 h'dVAC ESIID IGH3720P05167),.0 REVI8ION5 es R TIC N I DA7e I RF\/ PROJEC t NAMF A ADDRE>Ei Q U7 u5 O U h _i o Q LU Q? C7 m U) z LU X F a © Ir � X w < O 0 Fes- W � C7 it < m W Y ev Cp N DATE �10116t2:Je4 - ^_ SHEET NAME COVER PACE SHEET SIZE . r ANSI B 11" X 17" SHEET NUMBER �..... P V-1 ITE NOTES A LADDER SHALL BE IN PLACE FOR INSPECTION IN COMPLIANCE WITH OSHA REGULATIONS. THE PV MODULES ARE CONSIDERED NON-COMBUSTIBLE AND THIS SYSTEM IS AN UTILITY INTERACTIVE SYSTEM WITH NO STORAGE BATTERIES. THE SOLAR PV INSTALLATION BHA[ PROPER ACCESS AND WORKING C LEGEND ,N) JJ.JWTl',)N BOX ,Ej _91LITY METER IF) MAIN SERVICE PANEL o2) SUB PANEL IM ENPI-ASE IsQ CrIVRINER (N)VISE LE 1_00ASLE UkBlED Fji3O,ANNECT VENT ATTIC FAN (ROOF ,'BSTRIJCTIONI ROOF ATTACHMENT CONDUIT ENPIASE IO8PLUS 42-2-IjS Q'140VI MICRI'ANVE-RTER LONG1 LR5-54KAPI340001 MODULES RONRLIGE CLACK XR-10 RAIL 168 TRENCH 0 (E) PATI PR E�Ty TREES [El DRIVEWAY 2-STORY HOUSE tIE 3 POOL (EI, CHIMNEY (TYP__) 0 (E)FENCE M tEi AUTOMATIC TRANFER SWITCH P,Cl'�_T_"Jli PHONGTRUONG 144185 Date Signed: 1030.24 Firm Number: F-23402 I ' 1 F _L IV I Y (1t, I, it PI A tj`S 5 0' Ill K I P I ON JAu-'Ilr'_-TAII nov, A' I CHA W& S fAllj IlF IPP IIA Fl! METER NO#: 191113270 EQUIPMENT SUMMARY j ESIID#:10443720006167050 VISIBLE LOCKABLE LABELED DISCONNECT LOCATED ON 18 LONGI LR5-54HABB400M MODULES ACCESSIBLE EXTERIOR WALL WITHIN 10 FEET OF SCALE: 1/32"= 1'-0 18 ENPHASE 108PLUS -72-2-US (240V) MICROINVERTERS UTILITY METER lw A5_v VANTAGE POI PIT SOLAR 1910 PA CI Ff C AVE SUI TE 9250, DALLAS, TX 75201, USA PH# 1 18) 97 . ,8 .45376 SYSTEM JNPF`� 18, LONG Lr,f�,IHAUO.400PI ,18 CNPHAIE bjfiPLUo -72 2US 1240VI GC 5)(STEN1 SIZE 7 20,1 o VDIC ACS"RH:IZE 54001,VVAt; ES110 ME TER l) 1113270 REVISIONS IIEICRIFTI,`N � FAT I-, iR&v PRORC�r NAME &ADDRESS DATE 10M2024 SHEET NAME SITE PLAN SHEET SIZE ANSI B 11 " X 17" SHEET NUMBER PV-2 ESIGN SPECIFICATION MODULE TYPE, DIMENSIONS & WEIGHT RISK CATEGORY: 11 1 NUMBER OF MODULES: 18 MODULES ROOF ROOF CONSTRUCTION SFD MODULE 1 TYPE. LONGI LR5-54HABB-400M TILT ZONING: RESIDENTIAL MODULE WEIGHT: 49.6 LBS #1 40` SNOW LOAD (ASCE7-16): 5 PSF MODULE DIMENSION& 67.79" X 44.64" = 21.01 BE #2 39' EXPOSURE CATEGORY: C UNIT WEIGHT OF AREA: 2,37 PSF WIND SPEED (ASCE7-16): 105 MPH LEGEND ARRAY AREA & ROOF AREA CALVS ftjJNCTlDN&,A ROOF # OF MODULES ARRAY AREA (Sq. Ft.) 41 4 9 189,14 1 ,E) UTILITY METER #2 9 189.14 tc) MAIN SERVIrE PANEL (TOTAL ARRAY AREAfrOTAL ROOF AREA) X 100% �E) SUR PANEL = (3'878,27/3917) X 100%= 9.661 �W ENPHASE Q rIMBINER iN) ISELELOCKAPLELABEI-ED [)IllvCNNFCl 10 VENT, ATTiO FAN (ROOF QOCSqTRU F ATCTITAC�iCN) RNCNT CONDIA I' rNPlA'3E UMPLUS -724 US 12,10V) MICR"ANVCRTFR LCN','I LR5-S4HAEE4400M MOEAAES I RONRDGE RACK XR tO RAIL 68 TRENCH Dite Signed: 10.30.24 Firm Number: F-23402 SCALE: 3/32"= ll-W ROOF DESCRIPTION RAFTER RAFTER ROOF MATERIAL SIZE SPACING 2" x 24'o,c. COMP SHINGLE 2" x 24"o.c. COMP SHINGLE . It a A, cl 1� 'A !Ei AUTOMATIC TRANFER SWITCH METER NO#: 191113270 EQUIPMENT SUMMARY j ESE ID#:10443720006167050 VISIBLE LOCKABLE LABELED DISCONNECT LOCATED ON 18 LONGI LR5-54HABB400M MODULES ACCESSIBLE EXTERIOR WALL WITHIN 10 FEET OF 18 ENPHASE 108PLUS -72.2-US (240V) MICROINVERTERS, UTILITY METER "Aff-rt 1z �-Ao VANTAGE PNI (Yr SOLAR 1910 PACI Ff C AVE SUI TE 9250, DALLA;, TX 75201, USA r"J# 1 18) 97 . ,8 .45376 SYSTEM IWr 1 18, LONG L`1�54HAUO.40R,l I id) CNPHAIE 108PLU, -72 2US 124WI DC 5YSTEN1 SIZE -, 20,1 KvVDC: ACS"RM�IZE 5401JWIVAt L'slit) IW43-hO+)01,1671050 METER l) 1113270 REVISIONS 11ElCRl'TPN � CAIF j R&v PROR,'�IFNAME &ADDRESS so Itca - LU z 0 wc) (t) z Qw.I- 0 w 0 0 > C5 xw - cff z F- LU 0 Z W ED w (o cli DATE 10M2024 SHEET NAME ROOF PLAN SHEET SIZE ANSI B 11 " X 17" SHEET NUMBER PV-3 EQUIPMENT I OTY SOLAR PV MODULE 118 JINVERTER 118 JUNCTION BOX 12 10 COMBINER BOX Il FUSED AC DISCONNECT 1 ATTACHMENT 48 ATTACHMENT 96 ENPHASE Q CABLE 22 BRANCH TERMINATOR 3 10 WATER TIGHT CAP 4 RAILS 13 BONDED SPLICE 6 ICLAMPS 46 ICLAMP 20 1 GROUNDING LUG 5 BILL OF MATERIALS ESCRIPTION ONGI LR5-54HABB400M NPHASE 108PLUS -72-2-US (240V) UNCTION BOX. NEMA 3R, UL LISTED NPHASE IQ COMBINER 4 W/10 GATEWAY <40-AMI-240-4) OA FUSED AC DISCONNECT, (2) 30A FUSES, 24OV, NEMA R. UL LISTED IALO ULTRAGRIP -BLACK (QM-HUG-01 -Bl) ELF DRILLING SCREW. #14, WOOD TIP WITH WASHER, PDM BACKED NPHASE 0 CABLE 240V (PER CONNECTOR) RANCH TERMINATOR ) WATER TIGHT CAPS RONRIDGE BLACK XR-10 RAIL 168 PLICE KIT INIVERSAL FASTENING OBJECT (UFO) TOPPER SLEEVE tROUNDING LUG ___j U3 rn 0 70 —Tl 70 rTI Lil rTI rTI SCALE: 3/32"= 1'-0" i y MODULE STRINGING 16` FIRE SETBACK 18" FIRE SETBACK — — — --------- ------ VANTAGE P01 Nr SOLAR 1910 PACI Ff C AVE SU TE 9250, DALLAS, TX 752101, USA Phj# 1 18) 97 . ,8 .45376 SYSTEM Wr r 18, LONG Ls,��5IH1Eo.400r,l ,18 ENPHAIE IjfipLUo -72 2US 124W� DC 5YSTEN1 SIZE 7 20,1 Ke VDIC ACS"TBI�IZE 54000VAt L'Sllt) ](,`43-hOr)01,1671050 METER l) 1113270 REVISIONS DECRPTPN � DAIE- R&v PI OR,'� r NAME &ADDRESS so > )< (j) -i DATE 10)1$r2024 SHEET NAME STRING LAYOUT & BOM SHEET SIZE ANSI B 11 " X 17" SHEET NUMBER PV-4 SEE (2) FOR ENLARGED VIEW ATTACHMENT DETAIL SCALE `ITS UNIVERSAL MID CLAMF ,Up kylam cil'ollmal ENLARGED VIEW (ATTACHMENT DETAIL) SCALE NTS IRONRIDGE HALO ULTRAGRIP IRONRIDGE XR10 RAIL (168) 2"X6" RAFTER @ 24"OC SELF DRILLING SCREW, #14, NOCID TIP WITH WASHER, EPDM 3ACKED EMBED. MIN, 2.-;" INTO ROOF FRAMING PH ONG TRUONG lw A5-v VANTAGE POI Nr SOLAR 1910 PA CI Ff C AVE SUI TE 9250, DALLA5, TX 75201, USA PI-j# 1818) 97.4537.6 SYSTEM Wr � 18, LONG LR ,18 ENPHAIE IjfipLUo -72 2US 124WI DC 5YSTEN1 SIZE -, 20,1 KvVDC: ACSYWBI�IZE 54001,VVAt L'Sllt) IW43-hO�)01,1671050 METER l) 1113270 REVISIONS DESI'RPTPN � DOE- l R&v PRORC�r NAME &ADDRESS so X -i UJI z ul g (9 0 () > (t) z Qw. 0 w 009LO0 S 0 (D 0 1> 0 w 0� � z 0 F— LU z 0 ct: = LU < ED 13 w (o cli 1�-J DATE 10M2024 11441 ME SHEET NAME ATTACHMENT -TER @ 24"O,C DETAILS SHEET SIZE ANSI B Date Signed: 10 30.24 11 X 17" Firm Number F-23402 SHEET NUMBER PV-5 .62 46 i 7 1.33 00 P-4 Q--,Vc" ; " A—_ 1 ('- ji rod Rvx k ` uri Lllesc'irtOn i 4atigTfT Numbcr XR2- I --i- i J2A XR- Iu- 132b X,," -1 Rail 132)" i I f et- X k I 'j I 68A XR I i68B X R - 0, Rail 168' i 14 h, (- t 1) 5.96 FZ- XR -I )-2r',4A XK-10-20,13 XR' 204" 117 Petl 7 - ;*- I vI 0 {'Ili flpllH. Alt M eu' nm:'� '4W A VANTAGE POI Nr SOLAR 1910 PA CI Ff C AVE SUI TE 9250, DALLA5, TX 75201, USA PI-j# 1818) 974 53. SYSTEM Wr t 18, LONG -R ,18 CNPHAIE IjfipLUo -72 2US 1240Vl DC 5YSTEN1 SIZE -, 20,1 KvVDC: ACS"TBI�IZE 5401JOVAL L'Silt) IW43-hOt)01,1671050 METER l) 1113270 REVISIONS DECRPTPN � DAZE- j R&v o s r- 9 — X UJI Z U.1 g (9 0 W jj� @) o > (t) z (D In a 9 co w 0 0) (9 > C5 x- cff z F- LU 0 Z Bf =1 7: W ED w (o cli DATE 10M3t2024 SHEET NAME ATTACHMENT DETAILS SHEET SIZE ANSI B 11 " X 17" SHEET NUMBER PV-6 I7 TYPICAL INITVILCONDUCrOR LOC.T Is iN I FINA.<.ONDU':IOR LOCATION CONDIJC1uR CQN0111E I #CM PARALLEL, CURRENFCARRYIN+, CCINDUC, I OR IN '. UNDUN FILL Ut IUD EUC FEMP CIRR GOO NUUIi CANT WIX Fi+M,E DERATED IEN,;Ifl 'ACTOR FILL c. JRRCNT C4RRCN7 AMP ART VOI10;[: PROF CIRCUITS CIRCUIT ('ER'.ENT FAPTOR � ARRAY JJNc n(.,N BOx 12 Al'A Ct CABLE i "+ PIW N+,i 6AWT CARL 071 i 110 NIA 1270A 1513A, NA NIA 35rr 04,< CPPPCR 2 .:ll NATION EiQk .0 CO1s1t31NEi1 BOX 4 10 AVr THtNN2 COPPER MIN 075"NIA 2 I 4 277E°., 20A 6Afl* THIIFN2 0''1 11?C 48 1210A 151111 IFA ( 2!r48A `;VT 0i1°s. EMT t UFPER [ 3 t IQ tC�MEINE:R G'f)#4 FUSCb AC •,a AVu,y ifFAN "s LUPFER Mihl Ji`:'DIA I 3 144p^.s, 35i BAVVti ThP AN-2 U9i I.+-'I,Y i ?1 (Bii A23A 55+, ;`�€bA EFT OOJ'o = DISLONNECT CFO, � COFPCR 4 i REED Ak, AT$ IA`lw( THICN2 COPPER MIND"i'DIA) 1 3 34'.H% CLA N/A, NA0111 1 2178. :, 21A ,;'1N 5v1i5A SFT OOr9 DI SCONNLOT ' LA4T ,i-'CI 1 EQUIPMENT SUMMARY 18 LONGI LR5-54HABB-400M MODULES ' 18 ENPHASE 108PLUS 42-2-US (240V) MICROINVERTERS BRANCH 1 10- L01 ICI CR5-54HABB- I0QMf4e(W 411XIO 1PLlS iI BRANCH 2 08- LONGI LR5-54H% 5B-400M(4iH}W I MODULES - PrAK O^_,LITRI-- P Cl-WIT ALA _ .I'..,.z.,n,•F r<. -,;_I.�:-: ta., co- <;:a;.= SCALE: NTS METER = '". ,. _.i,ti P„N€ ill '-NTlIR:GNP1fiil. Pd`,> 1pc•t.:,lnc lAr-.=•Tt3'>€nn€Ic4�rr-r=� F,:, '-.i, ,• ;;,,. CONN[--T.F. IPCNI OOv FH1 H 55U TABLE EVR US: - ;04 THE L HE SIDE OF THE SFR` 4,,£ RAI PF, ENT t;: w V- - w J 1NFT C,N Pik CATE'AAY 0A lEW,31, t •N n i' - r {i:F n. f.,.,.t,-ac NFMA :t,; s=[,-'.Ter 2PA.^P IN; FNi'HA.F .'C,NIS NFP. R-s . A 10 AMI 24 t- METER NO#:191113270 ESIID#:10443720006167050 VISIBLE LOCKABLE LABELED DISCONNECT LOCATED ON ACCESSIBLE EXTERIOR WALL WITHIN 10 FEET OF UTILITY METER L 1a Date Signed! 10.30.24 Firm Number. F-23402 SERVICE INFO UTILITY PROVIDER: ONCOR AHJ NAME: GRAPEVINE CITY MAIN SERVICE VOLTAGE: 240V MAIN PANEL BRAND: SOURRE D MAIN SERVICE PANEL: 200 A MAIN BREAKER RATING: 200 A SERVICE FEED SOURCE. UNDERGROUND e. � s VANTAGE POI Nr SOLAR 1510 PA.,I FI C AVE SUI TE 9250, DAL LA5, TX 75201, USA Phut'!Hi8)9.4.5376 SYSTEM INF%� t.18, LONG LFif-541PAUB�400t-0 18 E:NPMASE IjfipLUo --". 2 2US 124AP GC 5YSTEM SIZE -, 20,1 R VDIC AC S"R flM IZE 54001,VVAt E:SIIU l(O-13?zry,0516710,50 FIF TER 1)1113270 i REVISIONS DESCRIPTI-'N DOE- EF-v i I PRORC: f NAME &ADDRESS so >< J t% LU C Z W d Gwi C5 � m 0 F— W ? Gl 0Z W � w ,;z ED W {li DATE 10M`9 2024 _. SHEET NAME .. �... ELECTRICAL LINE & CALCS. .. SHEET SIZE " ANSI B 11" X 17" I SHEET NUMBER Pv-7 I (MANUFACTURER/MODEL IVMP FC ISO TEMP. TEMP. COEFF, VOC j PTC RATING MODULE DIMENSION PANEL WATTAGE SOLAR MODULE SPECIFICATIONS LONGI LR5-54HABB-400M 30.94 V 12 93 A 37 05 V 13,72 A -0.27%/K 387.73 W 67,79"(L) x 44.64"(W) 400 W I INVERTER SPECIFICATIONS I MANUFACTURER / MODEL j ENPHASE IQ8PLUS -72-2-US (240V) I MAX DC SHORT CIRCUIT CURRENT 15 A I CONTINUOUS OUTPUT CURRENT 1,21 A raw i� RECORD LOW TEMP AMBIENT TEMP (HIGH TEMP 2 a) CONDUIT HEIGHT ROOFTOPTEMP CONDUCTOR TEMPERATURE RATE MODULE TEMPERATURE COEFFICIENT OF VOC PERCENT OF VALUES 0.80 0.70 0.50 -91C 3T C 7/8" 59"C 90°C -0.27 %/K NUMBER OF CURRENT CARRYING CONDUCTORS IN EMT 4-6 7-9 10-20 Bate Signed: I0.30.24 Firm Number: F-23402 � s t VANTAGE P01 Nr SOLAR 1510 PACI FI C AVE SUI TE 9250, DALLA5, TX 75201, USA Phut'!Hi8)9.4�5376 SYSTEM IWr% VOLTAGE RISE IN Q CABLE FROM THE MIC:ROINVERTERS TO THE JUNCTION BOX 14,tnNc1 id) E:NPMASE FOR BRANCH CIRCUIT #1 OF 10 IQ8PLUS MICROS, THE VOLTAGE RISE ON THE. 240 VAC Q CABLE IS 0.46% s u 72zTUSQ40Vl FOR BRANCH CIRCUIT #2 OF 8 IQ8PLUS MICROS, THE VOLTAGE RISE ON THE 240 VAC 0 CABLE IS 0.30% GC S"TBISIZE ; ;A AC SYSTL�E4 :IZ.E 5�4C�0 kVVAt; 4001, VOLTAGE RISE FROM THE JUNCTION BOX TO THE IQ COMBINER BOX 4 LIS110 10113 17,H1516'Jitl METER 151113270 VRISE = (AMPS/INVERTER X NUMBER OF INVERTERS) X (RESISTANCE IN OHMS/FT.) X (2-WAY WIRE LENGTH IN FT.) = (1,21 AMP X 10) X (0.00129 OHMS/FT) X (70 FT X 2) I REVISIONS (aEs:wcTo N ae Te I R&v = 12,10 AMPS X 0.00129 OHMS/FT) X 140 FT i I = 2.19 VOLTS I %VRISE = 2.19 VOLTS = 240 VOLTS = 0.91% THE VOLTAGE RISE FROM THE JUNCTION BOX TO THE IQ COMBINER BOX 4 IS 0,91% VOLTAGE RISE FROM THE IQ COMBINER BOX 4 TO THE FUSED AC DISCONNECT P (}lE,:rrdAMe&A DRESS VRISE = (AMPS/INVERTER X NUMBER OF INVERTERS) X (RESISTANCE IN OHMS/FT.) X (2-WAY WIRE LENGTH IN FT.) = (1.21 AMP X 18) X (0.00051 OHMS/FT) X (5 FT X 2) = 21,78 AMPS X 0,00051 OHMS/FT) X 10 FT = 0.11 VOLTS %VRISE = 0.11 VOLTS + 240 VOLTS = 0.05% THE VOLTAGE RISE FROM THE 10 COMBINER BOX 4 TO THE FUSED AC DISCONNECT (2-WAY WIRE LENGTH IN FT.) = (1.21 AMP X 18) X (0.00051 OHMS/FT) X (5 FT X 2) = 21.78 AMPS X 0,00051 OHMSIFT) X 10 FT = 0,11 VOLTS %VRISE = 011 VOLTS = 240 VOLTS = 0.05% THE VOLTAGE RISE FROM THE FUSED AC DISCONNECT TO THE ATS IS 0.05% TOTAL SYSTEM VOLTAGE RISE FOR ALL WIRE SECTIONS 0.46% + 0.91 % + 0.05% + 0,05% = 1,47% �: ura•., xu..1 iGta : ift"I; N`.; i +N{-♦:t ('r f¢F kC so c� w :E ca C9m W Z w � I- ti O w (9 > U z 0 0 F— W 1 C1 0 ct: - a W < ED W x ui cu DATE 10M`9 2024 SHEET NAME SPECIFICATIONS & NOTES SHEET SIZE ANSI B 11" X 17" SHEET NUMBER PV-8 1-1 ELECTRIC SHOCK HAZARD TERMINALS ON BOTH LINE AND LOAD SIDES MAY BE ENERGIZED IN THE OPEN POS I C ON LABEL LOCATION POINT OF INT, ERCONNECTION MAIN SERVICE DISCONNECT, AG DISCONNECT, AD C,' DMBINER, INVERTER PER CODE. NEC 690 1 ',(R! CAUTION 'SOLAR ELECTRIC SYSTEM CONNECTED LABEL LOCATION POINT OF INTE20ONNECT11-N & INVERTER PER CODE NEC 690 15 &,590 1'(B) TURN RAR D SHUTDOWN SWITCH TO Ti-E OFF' E� , ITION TO SHUT DOWN PV3YSTFM AND REDUCE SHO,"X HAZARD IN THE ARRAY LABEL LOCATION MAIN SERVICE DSCONNECT FIVISDISOILTSCE PLACIFITTHERE,IF M14-11SINSIDE PLACE ONTI-F AC DISCONNECT PER C�C-CE 2020 NEW 900 55iC) 4] LABEL LOCATION AC DISCONNECT PERCODE NE,*:6905T3(C)RI F-51_g. 4W. 9 A &Q, LABEL LOCAl ION AC DISCONNECT PER CODE NFPA 70, NEC 690 14 F12] F8 L: E"r A"Naia"gain LABEL I-OCATION, INVERTER AT ORVVITHNTOF THE D.--wCMIBNE.R SWITCH PER CODE NFC,390 56(0)12, LABEL LOCATION POINT OPINTERCONNECTION PURCODE NEC%6 10 LABEL LOCATION POINT OF INTERCONNECTION PER CODE NEC705 12(C) Fl-11 LABEL LCo,,ATIrN AD DSCONNECTfPREAMERPOINTS OF CONNECTION PER CODE NEC, 690 13(8) MANSERVICE DISCONNECT! AC DISCONNECT, MAIN SERVICE PANEL` REVENUE METE AC COMBINER PERCOITE 2020 NEC 705 12(C) Date Signed: 10.30.24 Firm Number: F-23402 ADHESIVE FASTENED SIGNS THE LABEL SHALL BE SUITABLE FOR THE ENVIRONMENT WHERE IT IS INSTALLED. WHERE REQUIRED ELSEWHERE IN THIS CODE, ALL FIELD APPLIED LABELS, WARNING AND MARKINGS SHOULD COMPLY WITH ANSI 2635.4 [NEC 1 1021(B) FIELD MARKING]. ADHESIVE FASTENED SIGNS MAY BE ACCEPTABLE IF PROPERLY ADHERED, VINYL SIGNS SHALL BE WEATHER RESISTANT [IFC 605.11.13) I Alool, VANTAGE POI Nr SOLAR 1910 PA CI Ff C AVE SU TE 9250, DALLA;, TX 75201, USA PH# 1818)9745376 SYSTEM Wr 18, LONG Lr,f�,!HAUO.40R,l , id) CNPHAIE 108PLU, -72 2US 124WI GC SYSTEM SIZE -, 20,1 K� vl)l� "RH ACS�IZE 54001,VVAt METER l) 1113270 REVISIONS DESI;WTI„N � NOE- R&v PRORC�r NAME &ADDRESS DATE 10M2024 SHEET NAME SIGNAGE SHEET SIZE ANSI B 11 " X 17" SHEET NUMBER PV-9 A M I I ,,,1 5, - H,p, RYA fl?t,)VP F, N AI6 fc'FF Kt P F ANDrEw " LOPEZ 146865 Date Signed: I O. 30,24 Firm Number. F-23402 LABEL LOCATION: EACH SERVICE EQUIPMENT LOCATION AND AT THE LOCATION(S) OF THE SYSTEM JDISCONNECTiS) FOR ALL ELECTRIC POWER PRODUCTION SOURCES CAPABLE OF BEING INTERCONNECTED (PER ODDE NEC 705 10) lw A5-v VANTAGE POI Nr SOLAR 1910 PA CI Ff C AVE SUI TE 9250, DALLA5, TX 75201, USA PH# 1818)97 . .45376 SYSTEM Wr � 18, LONG -R ,18 CNPHAIE IjfiPLUo -72 2US 124W� DC 5YSTEN1 SIZE -, 20,1 F VDI: ACSYWBI�IZE 5401JOVAt L'Sllt) IW43-hO+)01,1671050 METER l) 1113270 REVISIONS DE,,';RJPT-`N � DAIS- R&v PROR,'� r NAME &ADDRESS DATE 10M2024 SHEET NAME SIGNAGE SHEET SIZE ANSI B 11 X 17" SHEET NUMBER PV-10 OR Gl.ballyvaliditec - gh m.d,ft 30 Complete Syst— and P.d-tCc14<.b- - hUI 1UN C,;IY Ar PROVf:D P1 AW; III FIF KFPI ON MLjoc, 11ir-, Al M I llmt 0 W ". L 24 1u lw AW VANTAGE POI Nr SOLAR 1910 PA CI Ff C AVE SU TE 9250, DALLA5, TX 75201, USA PhJ# 1818)97 . .45376 SYSTEM INFr t18, LONG Lf,;��,!HADD�400r,l ,18 ENPHAIE IjAPLUo 72 2US i24W� DC SYSTEM SIZE -, 20,1 Kt VDI: ACS"TBI�IZE 5401JOVAt; L'Silt) IW43-hO+)01,1671050 METER In 1113270 REVISIONS DECRPTPN � DAIS- IR&v PROR,'�r NAME &ADDRESS D u') o s I- x -j Q < G LU z 0 WO Z UJI w Q. 0 (D (D > C5 x LU � z F— W Ca z 0 W < ED 2 w cN (o cli DATE 10M2024 SHEET NAME EQUIPMENT SPECIFICATIONS SHEET SIZE ANSI B 11 " X 17" SHEET NUMBER PV-1 I TY -�IOM IlC,IAUI,f OP C, Al J, App"I'VIL, III AN'; 10 UE Mt PC uu T,TL Al AU IMIL, L Hy N611LBE AVC.", lw AW VANTAGE POI Nr SOLAR 1910 PA CI Ff C AVE SU TE 9250, DALLAS, TX 75201, USA PhJ# 1818)97 . .45376 SYSTEM Wr � 18, LONG Lr, ,18 ENPHAIE IjfipLUo -72 2US i24WC DC 5YSTEN1 SIZE -, 2FCJ Kvvl)C: ACSYWBI�IZE 5401JOJAt; L'Silt) METER l) 1113270 REVISIONS DESCRPTI-`N � DAZE IR&v &ADDRESS D o s I- (,) , x -j p < G LU :E —1 Z U.1 g (9 o 0 > @) (t) z Qw. CC (D w 0 In a 9 w 0 �-) (D > C5 xw - cff z F- W 0 Z W ED 13 w cli (o DATE 10M2024 SHEET NAME EQUIPMENT SPECIFICATIONS SHEET SIZE ANSI B 11 " X 17" SHEET NUMBER PV-12 Ms� i 'Ill"n al :Il W, t.qfa, tova� i '-, � -a 1-1, �W Q lr[Nt, 1A E. m it 11 14 JP' tit, -41F DESCRIPTION STY B JB-12 "AJ 12 WK411 IdbilS, SKIT I IT 15-20 LOS UL 1741. NEMA 3R GSA G22,2 NO. 290 145 LBS m Hjl'zVATfAlIA ;lr4111Wll PILA PFW UN X" :11F P1 At I TIME, VANTAGE POINT SOLAR 1910 PAQ FI 0 AVE ' 'U TF 9250, DALLAS, TX 75201, USA PH(818)9745375 SY:T-MINF, t 1 tt� LONCA -r5.l-!HA66.40(f,1 081E�NPHASE QRPLIJSi22-0',iNWI FJC$YSTEMIZE 7200klnVC AC I Y 4 M-P! '17L 5 400 KWAG ES110 IW137h0t)06M050 METER 15M3270 " ISIONS DF9�,RIP rfl:�N I WF� I RFV PROJECT NAW. ADDRESS loll 2i 0 X < tQ LLJ Z Uj g (D 0 o (') @) > co z CC r- (D Lu 0 00 (D d uj z w Z -0 -j LU m w 04 DATE 10M6/21J24 —iHEE—T NAME EQUIPMENT SPECIFICATIONS SHEET SIZE ANSI B 11 X 17" SHEET NUMBER PV-1 3 5" EZf SOLAR EZf SOLAR lF B JB-1.2 TX� WUH1 1451,q SPUN' Of 3 OUISIDE INSIDE t —1`ii 11— A40 11- --------------------------- r I 01� Mot RE UISKI �('R CON'"'LILHON clly.- PPUVEI: PLAW; 10 W Kt. p I Uti if if J0 li r, fl F A I A, LL T IMI P, LWE li V-111,14 Al 01. -Ml' f39j VANTAGE POINT SOLAR 1910 PACIFICAVE "UTF 9250, DAL AS, TX 75201, USA F'Hf �' 8 18) 9 74,5375 SY:T -M I NP l 1 8� LONCA Lr5.l-!HA66.40R,l t 181 ENPtAASE OR, J S ' , 2 2- U, i N W DC $)'STEM IZE 7200 5400KWAG ES110 IW137h0�)06M050 METER 15)M3270 KVISIONS DF9�,RIP rll:�N I -11 R111 PRO JEC T NAMt; & ADDRESS loll 2i 0 < LLJ z Z o (u), 5 cr 0) Z �U'l I ul .0 0 Z�) 0 UJ z F- W Z 0 cr -j LN m w 04 PATE iOMZ21;24 SHEET NAME EQUIPMENT SPECIFICATIONS SHEET SIZE ANSI B 11 " X 17" SHEET NUMBER PV-14 ASY -TAP - I Ri Il A, VANTAGE POINT SOLAR 1910 PAQ FI 0 AVE ' 'U TF 9250, DALLAS, TX 75201, USA F'Hf (818)9745375 SY:TCM INPi l 1 8� LONCA -r5.l-!HA6B.40(f,l 4181 ENPtAASE 108PLIJS 4 2 2- JS i NW, FiC $)'STEM IZE 7200 5400KWAG ES110 IW137h0�)06M050 METER 151113270 " ISIONS DF9�,RlPrfl.�Nl tXrF. JRFV PRO JEC T NAMt; & ADDRESS DATE 10M6/21J24 SHEET NAME EQUIPMENT SPECIFICATIONS SHEET SIZE ANSI B 11 X 17" SHEET NUMBER PV-1 5 fklg{- P"t I A�A 0 609 111k Jtiii >SIt All, I I I 'All VANTAGE POINT SOLAR 1910 FACT FIC:AVFSUITE 9250, DALLAS, TX 75201, USA PH,ll YSTEM INFO 118) LoNcll LP '5-,54HA@8-I0C.KI 111 EN"HAS1 "a'�L'7 - 2 2 U1 :24WI DC ',YG TEM SIZE 7 200 04M AC SY iILM 61ZE 5.100 WWAi L6IID GWi720QCWf,7Q,',0 PETER 181113270 REVI$IONS DESCRFHO] DAFF REV PRCXIE�' T NAME & ADDRE3:i Lr) 0 X LU z Z ILL o 3 LU W z 0- 0 w 0- 0 a So- s o �) 0 > 0 X w � z F— W > Z i 0 LU 4,1s 0- m 2 2 w DATE 10V162024 SHEET NAME EQUIPMENT SPECIFICATIONS SHEET s�zE ANSI B 1 V X 17" SHEET NUMBER PV-16 NNETKWIEE� When integrating with a home solar attachments must be dependable for the lifetime of the rooftop Due to recent innovations, many asphalt shingles have bonded courses A mount that protects without the need to pry shingles can really speed things up, Halo UfraGnp' (HUG') is here to respect the root, Its Halo is a cast -aluminum barrier that encases the UldaGrip, our industrial -grade. foam -and -mastic seat. This allows HUG to accelerate the installation process and provide the utmost 4) waterproofing protection. Give your root a HUG! NEW UftmGnp- Seat Tbartnottriat r� 1 —1, The telt 'd—, ry , nna risw vtiv,�- rrv 4, is R.Na the R4611 ................. gz Mulft-Thared Waterproofing HUG WW1_ Adaptive, Rafter -Friendly Installation Trusted Strength & Less Hassle The rafter -mounted Parts are designed HUG has been and certified for tested and rated to Compliance with support 1004 (ley) of the International uplift and 368 has) Building Code & of lateral load. ASCE/SEI-7 Structural capacities of HUG' were ;nstalls, which means the following, No prying shingles No root nail interference No pilot holes necessary No sealant in most cases) • No buyti shims needed HUG passed both systems Conform to the UL 441 Section CIL 2703 mechanical 27 'Ram lest" and and bonding TAS 100(A)-96 rectu"emeres, See `Wind Driven Rate Rush Mount Manual Test' by Interrek, for more into, 11 fro .1 F K Viol, it;tilf-jsL U1 t L -LP F UR r.l fY AVf LD P1 AN S lQ10- Al-i'l nN I llt I A i A MR � t 1:,rl_E hY V1 1W i I H i1i 1W A51t VANTAGE P01 Nr SOLAR 1910 PA CI Fl C AVE SUI TE 9250, DALLA5, TX 75201, USA Pl-ilf 1818) 974 53. SYSTEM Wr 18, LONG L_c�5.ri1co.400hl ,18 ENPHAIE IjfiPLUo 72 2.1_c QlWl DC 5YSTEN1 SIZE 7 20,1 Kl VDI� ACS"Rrl:IZE 54001,VVAr; Uslit) IW437hO�)01,1671050 t 41�T �E R 1', 1113270 REVISIONS DE,,CRJPTPN � DA I E- I Ri-v PROJ�r:r NAME &ADDRESS o s h- (,) , x _j p < LU Z W 0 > (f) o z LU (D W 0 0 T_ W Cff >1 z 0 F- LU Ca z 0 LU < ED 13 ZE U.1 Oil (0 CI DATE 10M2024 SHEET NAME EQUIPMENT SPECIFICATIONS SHEET SIZE ANSI B 11 " X 17" SHEET NUMBER PV-1 7 Over their lifetime, solar panels experience countless extreme weather events. Not just the worst storms in years, but the worst storms in 40 years. High winds capable of ripping panels from a roof. and snowfalls weighing 4 enough to buckle a panel frame. A0 XR Rails ` are the structural oackdone preventing these results- They resist upirfilt protect against buckling and safely and efficiently transfer loads into Me building Structure. Their superior spanning capaiciffy requires fewer roof attachments reducing the number of roof penetrations and the amount of installation time Compatible with Rat & Pitched Roots Force -Stabilizing Curve n,, XR Rail, Family Corrosion -Resistant Materials XR Rail' Family The XR Rail! Family offers the strength of a curved rail in three targeted sizes Each size supports specific design loads, while minimizing material costs. Depending on your location, there is an XR Rail' to match. -,N ME, XFHOO XR10D0 S, It 14 11. Rail Selection The table below atas prepared in compliance with applicable engineering codes and standards.' letters 90 120 None 140 XR10 XR100 XAIOEO 160 90 120 20 140 160 90 30 160 90 40 160 80 160 120 160 1W AW VANTAGE POI Nr SOLAR 1910 PA CI Fl C AVE SU TE 9250, DALLA5, TX 75201, USA PhJtr 1818) 974 53. SYSTEM IWr 0 8, LONG -R.54HADD.400r,1 ,18 ENPHAIE bjfiPLUo -72 2,1-c 124Wi DC 5YSTEN1 SIZE -, 20,1 KvVDC: ACS"TBI�IZE 54001,VVAt; LIS110 103437h0r,01,1671050 t E 4U �R 1', 1113270 REVISIONS DESI;RPTPN � DA I E- I Ri-v PROA,=:r NAME &ADDRESS D 1-: Lro so x LU Z C) 0 W (t) Z QW. (D W 0 0 9 do 0 0 > C5 XW - cff Z F— W 0 Z W ED W C"I up Cu DATE 10M2024 SHEET NAME EQUIPMENT SPECIFICATIONS SHEET SIZE ANSI B 11 X 17" SHEET NUMBER PV-18 SOLAR-800f-CIECKCM A Riopous LOAD ANALYSIS DATE: 10-30-2024 FOR: YourSolarPlans, Inc. 3000 E. Birch St Suite 201 Brea. CA 92821 USA 4000 L Birch Street, Suite 20; Brea, CA 92621 Ph: 844- 783-5483 JOB: Hodgson, Jim 2621 Kimberly Dr Grapevine, TX 7601 This letter is to certify that we have performed a structural analysis of the existing roof members that are to support photovoltaic panels, as shown on the attached report. The calculations were performed in aLL2L40.wc ,2 with tl�te editions of IBC 2021 � 4�SCE 7-22. an* IRC 2021 . _• t4e buildinw codes for tke state of �M Ground Snow (psf) 5 psf Sloped Snow (psf), reduced per ASCE. Sect. 7.4 2,41 psf Basic Wind Speed (mph): 105 mph Roof Slope: 40 degrees The PV module orientation: Both The maximum horizontal roof mount spacing: 4 ft. The maximum vertical roof mount spacing: 2,833 ft. Staggered roof mounts required? Yes _♦ on this analysis, we can certify that the individual existing roof framing ♦_ that support the ?IV *'andls: ane tM iA4jyi4V'81-f#*f mawr4utrs as-itseri*6i. in the attaeh m�k#;M art a4,--#*at,- t-# svp"rt thfd design loads as required by the various codes. This includes Dead Loads (including the weight of the PV panels), Live Loads, Snow t=• and Wind Loads, on the roof members that support the PV panels, combined as required in the codes, FXAMITLMMUMP . -1 M-MMFIMHFM#"# please contact us at your convenience. NOTE, 1, Prior to commencement of work, the Solar Installer shall verify that the roof framing sizes. spacing, and spans (between supports), are as noted in these plans. The Engineer of Record must be notified if any discrepancies are discovered, before proceeding, 2. These plans are Stamped for Structural Code compliance of the of members that support the PV solar system only. 3. These plans are not stamped for rain water leakage prevention. 4As a !2recaufi olt or wet snow nhotild h=. rpm—... if the snow builds up to 18" or more. 0 Z's PHONG TRUONG 144185 Date Signed: 10.30,24 Firm Number: F-23402 RECEIVED: 11/4/2024 24-004006 2621 KfMBERLY DRIVE SOLAR PANEL I N S TA LL A TI 0 N Date of Report: 10-30-2024 Job Name: Hodgson, Jim Data Input by: Kevin Nguyen Job Number: 123 Contact E-mail: Job Address: 2621 Kimberly Dr Contact Phone: 7148721728 Grapevine, TX 76051 1#JMjrV=__ k TT using the input data supplied by the user, listed under Current Input Data. The user input has not been independently reviewed by a licensed Professional Engineer for appropriateness or indicates Compliance/Non-Compliance with the reference Codes listed below. The following items have been checked for Code Compliance: Load Combination #1: 0 0- 0 0 a O0 N d' =--, - Load Combination #2: Suwortina Rafter Strewth with: DL Rf + - Load Combination #3: Supporting Rafter Strength with: DL Rf + DL Solar + Wind Down Strength with: DL Rf + DL Solar + Snow - Load Combination #5: Supporting Rafter Strength with: DL Rf + DL Solqr +,754tivid +,75S=v m =wyminromill - Load Combination #7: Supporting Rafter Strength with: Wind Up - O�6 * (DL Rf + DL Solar) W �! I �11 l Data Input By: Kevin Nguyen Job Number: 123 Job Name: Hodgson. Jim Job Address: 2621 Kimberly Dr City, State: Grapevine, TX 76051 Current Input Data Payment Method Invoice Roof Type InteriorBearingWall Ceiling Type 1/2 gyp. Bd. Collar Tie Space 0 Coverage % 9.66 Frame Size 2x6@24 Ground Snow (psf.) 5 Sloped Roof Snow Load (psf) 2,41 Lag Screw Diam, (in) 1/4 Lag Screw Embed. (in) 2.5 Overall Span (ft) 30 PV Weight (psf) 3 PV Module Orientation Both Rafter Span (ft) 12 Rail System 2Rail Roof Mean Height (ft) 25 Roof Slope (degrees) 40 Roofing Type Asphalt Shingles Sloped Ceiling No Max. Horizontal Roof Mount(ft) 4 Max. Vertical Roof Mounts (ft) 2.833 Standoff Staggered Yes Wind Exposure C Wind Speed (mph) 105