Loading...
HomeMy WebLinkAbout72818_9080_51-cyl-mar15field test report 3642 euless grapvine 2424 STUTZ DR.  SUITE 400  DALLAS, TX 75235  TEL [214] 350 5600  FAX [214] 350 0019 CONCRETE CYLINDER TEST REPORT Grapevine Building A 3642 Euless-Grapevine Road Grapevine, Texas REPORTED TO: ARCO/Murray 4925 Greenville Ave., Suite 915 Dallas, Texas 75206 ATTN: Mr. Chase Killingsworth REPORT NO. 51 REG PROJECT NO. 25298 SAMPLE DATE: 03-15-24 TECHNICIAN: N. Kobzeff PAGE: 1 of 2 Location of Sample Set Number Location Quantity Represented (c.y.) 1 Pier: E-1 10/10 Design Information Source of Concrete Mix Identification Specified Strength (psi) Sample Size Estrada R3050NAWR 3000 4x8 Test Results Set No. Cylinder ID Date Tested Age @ Test Total Load (lbs.) Fracture Type Compressive Strength (psi) Average Strength (psi) 1 1490 03-22-24 7 52780 3 4200 1490 04-12-24 28 62510 3 4980 1490 04-12-24 28 61140 3 4870 1490 04-12-24 28 61500 2 4890 4910 1490 Hold H Cylinder Data Set No. Cylinder ID Slump (inches) Time of Sample Air Temp. (°F) Concrete Temp. (°F) Air Entrainment (%) Unit Weight (lbs/ft3) Ticket Number 1 1490 3.0 10:11 AM 59 68 2.1 N/A 163 Fracture Type Type 1 Type 2 Type 3 Type 4 Type 5 Type 6 Note: (1) Concrete was sampled in accordance with ASTM C-31 (2) Concrete cylinders were tested in accordance with ASTM C-39 REPORT NO. 51 REG PROJECT NO. 25298 SAMPLE DATE: 03-15-24 PAGE: 2 of 2 E-Mail Distribution: (2) ARCO/Murray/ Mr. Chase Killingsworth Mr. Brice Jones (1) Pritchard Associates/ Mr. Taylor Wildman (2) City of Grapevine/ Mr. Daniel Steinshouer Mr. Phillip Sedivy (2) DFW West Logistics One. LLC/ Mr. Bunker Curnes Mr. Tom Curnes Submitted by: REED ENGINEERING GROUP, LTD. Registration Number F-3114 Cary Tipps Project Manager, CMT CT/cn