Loading...
HomeMy WebLinkAbout72927_9138_102-den-may03 2424 STUTZ DR.  SUITE 400  DALLAS, TX 75235  TEL [214] 350 5600  FAX [214] 350 0019 REPORT OF FIELD DENSITY TESTS Grapevine Building A 3642 Euless-Grapevine Road Grapevine, Texas REPORTED TO: ARCO/Murray 4925 Greenville Ave., Suite 915 Dallas, Texas 75206 ATTN: Mr. Chase Killingsworth REPORT NO. 102 REPORT DATE: 05-08-24 REG PROJECT NO. 25298 TECHNICIAN: P. Butler PAGE: 1 of 1 Proctor No. ASTM Standard Description Optimum Moisture, % Maximum Density, PCF 1 D-698 Brown & reddish brown sandy clay 18.2 105.8 2 D-698 Reddish brown clay w/gray clay & sand 19.4 103.8 Test No. Date Location Depth Below Final S. G. (feet) Pocket Pen (tsf) Field Density (pcf) Field Moisture (%) Proctor ID Compaction Level (%) 1438 05-03-24 Sanitary Line A: STA 19+50 6.0 2.75 102.6 20.1 1 97.0 1439 Sanitary Line A: STA 19+51 5.0 2.5 101.7 20.8 1 96.2 1440 Sanitary Line A: STA 19+52 4.0 2.75 102.0 21.0 1 96.5 1441 Sanitary Line A: STA 19+53 3.0 3.0 102.7 19.6 1 97.1 1442 Sanitary Line A: STA 19+54 2.0 2.75 102.4 20.4 1 96.8 1443 Sanitary Line A: STA 19+55 1.0 2.0 100.9 22.5 1 95.4 1444 Sanitary Line A: STA 19+56 0.0 2.25 101.4 21.9 1 95.9 Comments: Where tested, materials were in compliance with project specifications. E-Mail Distribution: (2) ARCO/Murray/ Mr. Chase Killingsworth Mr. Brice Jones (2) Pritchard Associates/ Mr. Taylor Wildman Mr. Azra Spahalic (4) City of Grapevine/ Mr. Daniel Steinshouer Mr. Phillip Sedivy Mr. Israel Lozano/ Mrs. Kelly Taft (2) DFW West Logistics One. LLC/ Mr. Bunker Curnes Mr. Tom Curnes Submitted by: REED ENGINEERING GROUP, LTD. Registration Number F-3114 Bill Woolwine Sr. Manager, CMT BW/sp