Loading...
HomeMy WebLinkAbout73331_9330_151-den-aug09 2424 STUTZ DR.  SUITE 400  DALLAS, TX 75235  TEL [214] 350 5600  FAX [214] 350 0019 REPORT OF FIELD DENSITY TESTS Grapevine Building A 3642 Euless-Grapevine Road Grapevine, Texas REPORTED TO: ARCO/Murray 4925 Greenville Ave., Suite 915 Dallas, Texas 75206 ATTN: Mr. Chase Killingsworth REPORT NO. 151 REPORT DATE: 08-19-24 REG PROJECT NO. 25298 TECHNICIAN: B. Reed PAGE: 1 of 1 Proctor No. ASTM Standard Description Optimum Moisture, % Maximum Density, PCF 1 D-698 Brown & reddish brown sandy clay 18.2 105.8 2 D-698 Reddish brown clay w/gray clay & sand 19.4 103.8 Test No. Date Location Depth Below Final S. G. (feet) Pocket Pen (tsf) Field Density (pcf) Field Moisture (%) Proctor ID Compaction Level (%) 1618 08-09-24 Slab leave-out: H.3-1.4 0.0 3.5 99.2 21.4 2 95.5 1619 Slab leave-out: J.4-1.4 0.0 3.25 101.3 19.3 2 97.5 1620 Slab leave-out: K.2-1.4 0.0 3.5 102.1 22.4 2 98.3 1621 Slab leave-out: L.2-1.4 0.0 3.25 99.4 19.3 2 95.7 1622 Slab leave-out: M.2-1.4 0.0 3.0 99.8 22.1 2 96.2 Comments: Where tested, materials were in compliance with project specifications. E-Mail Distribution: (2) ARCO/Murray/ Mr. Chase Killingsworth Mr. Brice Jones (2) Pritchard Associates/ Mr. Taylor Wildman Mr. Azra Spahalic (4) City of Grapevine/ Mr. Daniel Steinshouer Mr. Phillip Sedivy Mr. Israel Lozano/ Mrs. Kelly Taft (2) DFW West Logistics One. LLC/ Mr. Bunker Curnes Mr. Tom Curnes Submitted by: REED ENGINEERING GROUP, LTD. Registration Number F-3114 Bill Woolwine Sr. Manager, CMT BW/sp