HomeMy WebLinkAbout73358_9342_157-den-aug15
2424 STUTZ DR. SUITE 400 DALLAS, TX 75235 TEL [214] 350 5600 FAX [214] 350 0019
REPORT OF FIELD DENSITY TESTS
Grapevine Building A
3642 Euless-Grapevine Road
Grapevine, Texas
REPORTED TO: ARCO/Murray
4925 Greenville Ave., Suite 915
Dallas, Texas 75206
ATTN: Mr. Chase Killingsworth
REPORT NO. 157
REPORT DATE: 08-23-24
REG PROJECT NO. 25298
TECHNICIAN: C. Damron
PAGE: 1 of 1
Proctor
No.
ASTM
Standard
Description
Optimum
Moisture, %
Maximum
Density, PCF
1 D-698 Brown & reddish brown sandy clay 18.2 105.8
2 D-698 Reddish brown clay w/gray clay & sand 19.4 103.8
Test
No.
Date
Location
Depth
Below
Final S. G.
(feet)
Pocket
Pen
(tsf)
Field
Density
(pcf)
Field
Moisture
(%)
Proctor
ID
Compaction
Level (%)
1648 08-15-24 Ramp: 65’N, 10’W(1) 0.0 2.75 102.0 19.5 1 96.4
1649 Ramp: 70’N, 40’W(1) 0.0 2.5 101.7 19.9 1 96.1
1650 08-16-24 Ramp: 70’S, 10’W(2)0.0 2.25 100.7 21.6 1 95.2
1651 Ramp: 70’S, 40’W(2)0.0 2.5 101.1 20.9 1 95.6
Comments: Where tested, materials were in compliance with project specifications.
Footnotes: (1) Measurements referenced from SW building corner.
(2) Measurements referenced from NW building corner.
E-Mail
Distribution: (2) ARCO/Murray/
Mr. Chase Killingsworth
Mr. Brice Jones
(2) Pritchard Associates/
Mr. Taylor Wildman
Mr. Azra Spahalic
(4) City of Grapevine/
Mr. Daniel Steinshouer
Mr. Phillip Sedivy
Mr. Israel Lozano/
Mrs. Kelly Taft
(2) DFW West Logistics One. LLC/
Mr. Bunker Curnes
Mr. Tom Curnes
Submitted by:
REED ENGINEERING GROUP,
LTD.
Registration Number F-3114
Bill Woolwine
Sr. Manager, CMT
BW/sp