Loading...
HomeMy WebLinkAbout73384_9353_163-cyl-aug27 2424 STUTZ DR.  SUITE 400  DALLAS, TX 75235  TEL [214] 350 5600  FAX [214] 350 0019 CONCRETE CYLINDER TEST REPORT Grapevine Building A 3642 Euless-Grapevine Road Grapevine, Texas REPORTED TO: ARCO/Murray 4925 Greenville Ave., Suite 915 Dallas, Texas 75206 ATTN: Mr. Chase Killingsworth REPORT NO. 163 REG PROJECT NO. 25298 SAMPLE DATE: 08-27-24 TECHNICIAN: E. Gonzalez PAGE: 1 of 2 Location of Sample Set Number Location Quantity Represented (c.y.) 1 Slab: B.5-1.4 10/30 Design Information Source of Concrete Mix Identification Specified Strength (psi) Sample Size Estrada Ready Mix R4055NASC 4000 4x8 Test Results Set No. Cylinder ID Date Tested Age @ Test Total Load (lbs.) Fracture Type Compressive Strength (psi) Average Strength (psi) 1 4210 09-03-24 7 44730 4 3560 4210 09-24-24 28 4210 09-24-24 28 4210 09-24-24 28 4210 Hold H Cylinder Data Set No. Cylinder ID Slump (inches) Time of Sample Air Temp. (°F) Concrete Temp. (°F) Air Entrainment (%) Unit Weight (lbs/ft3) Ticket Number 1 4210 4.75 10:08 AM 84 93 2.0 149.1 2965 Fracture Type Type 1 Type 2 Type 3 Type 4 Type 5 Type 6 Note: (1) Concrete was sampled in accordance with ASTM C-31 (2) Concrete cylinders were tested in accordance with ASTM C-39 REPORT NO. 163 REG PROJECT NO. 25298 SAMPLE DATE: 08-27-24 PAGE: 2 of 2 E-Mail Distribution: (2) ARCO/Murray/ Mr. Chase Killingsworth Mr. Brice Jones (2) Pritchard Associates/ Mr. Taylor Wildman Mr. Azra Spahalic (4) City of Grapevine/ Mr. Daniel Steinshouer Mr. Phillip Sedivy Mr. Israel Lozano/ Mrs. Kelly Taft (2) DFW West Logistics One. LLC/ Mr. Bunker Curnes Mr. Tom Curnes Submitted by: REED ENGINEERING GROUP, LTD. Registration Number F-3114 Cary Tipps Project Manager, CMT CT/cn