Loading...
HomeMy WebLinkAbout654207_38631_137-cyl-aug02 2424 STUTZ DR.  SUITE 400  DALLAS, TX 75235  TEL [214] 350 5600  FAX [214] 350 0019 CONCRETE CYLINDER TEST REPORT Grapevine Building A 3642 Euless-Grapevine Road Grapevine, Texas REPORTED TO: ARCO/Murray 4925 Greenville Ave., Suite 915 Dallas, Texas 75206 ATTN: Mr. Chase Killingsworth REPORT NO. 137 REG PROJECT NO. 25298 SAMPLE DATE: 08-02-24 TECHNICIAN: P. Mendoza PAGE: 1 of 3 Location of Sample Set Number Location Quantity Represented (c.y.) 1 Paving: 30’E from NE corner of Building 1 30/700 2 Paving: 80’S, 25’E from NE corner of Building 1 130/700 3 Paving: 180’S, 20’E from NE corner of Building 1 220/700 4 Paving: 310’S, 40’E from NE corner of Building 1 390/700 5 Paving: 410’S, 90’E from NE corner of Building 1 450/700 6 Paving: 530’S, 20’E from NE corner of Building 1 520/700 7 Paving: 620’S, 20’E from NE corner of Building 1 620/700 Design Information Source of Concrete Mix Identification Specified Strength (psi) Sample Size Estrada R4060AEWR 4000 4x8 Test Results Set No. Cylinder ID Date Tested Age @ Test Total Load (lbs.) Fracture Type Compressive Strength (psi) Average Strength (psi) 1 3676 08-09-24 7 69600 2 5540 3676 08-30-24 28 3676 08-30-24 28 3676 08-30-24 28 3676 Hold H 2 3677 08-09-24 7 62520 2 4970 3677 08-30-24 28 3677 08-30-24 28 3677 08-30-24 28 3677 Hold H 3 3678 08-09-24 7 38230 3 3040 3678 08-30-24 28 3678 08-30-24 28 3678 08-30-24 28 3678 Hold H REPORT NO. 137 REG PROJECT NO. 25298 SAMPLE DATE: 08-02-24 PAGE: 2 of 3 Test Results Set No. Cylinder ID Date Tested Age @ Test Total Load (lbs.) Fracture Type Compressive Strength (psi) Average Strength (psi) 4 3679 08-09-24 7 38040 3 3030 3679 08-30-24 28 3679 08-30-24 28 3679 08-30-24 28 3679 Hold H 5 3680 08-09-24 7 51170 2 4070 3680 08-30-24 28 3680 08-30-24 28 3680 08-30-24 28 3680 Hold H 6 3681 08-09-24 7 50670 3 4030 3681 08-30-24 28 3681 08-30-24 28 3681 08-30-24 28 3681 Hold H 7 3682 08-09-24 7 44000 3 3500 3682 08-30-24 28 3682 08-30-24 28 3682 08-30-24 28 3682 Hold H Cylinder Data Set No. Cylinder ID Slump (inches) Time of Sample Air Temp. (°F) Concrete Temp. (°F) Air Entrainment (%) Unit Weight (lbs/ft3) Ticket Number 1 3676 4.5 1:30 AM 74 90 4.0 146.7 2270 2 3677 5.0 2:15 AM 74 91 4.5 146.5 2280 3 3678 5.0 4:05 AM 75 92 4.5 146.6 2289 4 3679 6.0 5:30 AM 80 93 5.0 146.4 2302 5 3680 5.5 7:20 AM 83 93 5.0 146.3 2313 6 3681 5.0 8:30 AM 84 95 4.0 146.5 2321 7 3682 5.5 9:30 AM 85 95 5.0 146.4 2333 Fracture Type Type 1 Type 2 Type 3 Type 4 Type 5 Type 6 Note: (1) Concrete was sampled in accordance with ASTM C-31 (2) Concrete cylinders were tested in accordance with ASTM C-39 REPORT NO. 137 REG PROJECT NO. 25298 SAMPLE DATE: 08-02-24 PAGE: 3 of 3 E-Mail Distribution: (2) ARCO/Murray/ Mr. Chase Killingsworth Mr. Brice Jones (2) Pritchard Associates/ Mr. Taylor Wildman Mr. Azra Spahalic (4) City of Grapevine/ Mr. Daniel Steinshouer Mr. Phillip Sedivy Mr. Israel Lozano/ Mrs. Kelly Taft (2) DFW West Logistics One. LLC/ Mr. Bunker Curnes Mr. Tom Curnes Submitted by: REED ENGINEERING GROUP, LTD. Registration Number F-3114 Cary Tipps Project Manager, CMT CT/cn