Loading...
HomeMy WebLinkAboutDFW West Logistics Electrical Office As Built Documents_2024-12-165 6 P Q 5 6 P Q DSS-1 (INDOOR) T 5 6 P Q 5 6 P Q RTU-1 EF-1 DSS-1 28'-9" 18 ' - 2 " 12 ' - 1 " 15 ' - 8 " 14'-1" GFCI LOAD GFCI GFCI RTU-1 HO1-1,3,5 (3)#10,(1)#10G 26MCA,30MOCP DSS-1 LO1-1,3 (2)#10,(1)#10G 13MCA,15MOCP J CP-1 LO1-5 (2)#12,(1)#12G WH-1 HO1-7 (2)#10,(1)#10G 6.0kW J GFCI J J LO1- (8)#12,(1)#12G ####,## ##,## ## #### ## ## ## LO1- (4)#12,(1)#12G ## J LO1- (4)#12,(1)#12G LO1- (2)#12,(1)#12G GFCI GFCIGFCI ## ## ## NEW PANEL HO1 NEW TRANSFORMER TXLO1 NEW PANEL LO1 5 6 P Q 5 6 P Q T 5 6 P Q 5 6 P Q A4 A4 A4 A4 A4 A4 A4 A4 A4 A4 A4 A4 A4 A4 A4 A4 A4 A4/E A4 A4 A4 A4 A4 A4 A4 A4 B/E B B B B B B B B B B B B B B X1 X1 X1 X1 B/E B/EB/E A4/E A4/E A4/E A4/E NEW PANEL HO1 NEW TRANSFORMER TXLO1 NEW PANEL LO1 These drawings and/or Electronic files are the sole property of Hurst Electric. They may not be used, in whole or in part, reproduced in any form, by any method, for any purpose, without written consent from Hurst Electric. No person may make any modification to this electronic drawing file without the express written consent of Hurst Electric. Anyone coming into possession of this material other than by specific written agreement with Hurst Electric is hereby warned that use of such without written consent from Hurst electric will result in legal action for damages and other remedies. 229 W. HURST BLVD HURST, TX 76053 (817) 268-3000 0"1"If this plot bar is not exactly 1 inch long the physical size of the drawing has changed. SHEET NUMBER JOB NO : GA1054 REVISIONS AR C H I T E C T CI V I L : CO N T R A C T O R CO N S U L T I N G E N G I N E E R S ST R U C T U R A L : EL E C T R I C A L : PL U M B I N G : FI R E P R O T E C T I O N : ME C H A N I C A L : 79 3 0 C L A Y T O N R D . S T E 3 0 0 RI C H M O N D , H E I G H T S 6 3 1 1 7 (P ) 3 1 4 - 8 2 2 - 5 1 9 1 WW W . G M A - A R C H I T E C T S . C O M THIS DESIGN AND THESE DRAWINGS ARE THE PROPERTY OF GMA ARCHITECTS, INC. NO PART OF THIS WORK MAY BE REPRODUCED WITHOUT PRIOR WRITTEN PERMISSION FROM GMA ARCHITECTS, INC. HA L F F A S S O C I A T E S , I N C . 12 0 1 N O R T H B O W S E R R O A D RI C H A R D S O N , T X 7 5 0 8 1 21 4 . 3 4 6 . 6 2 0 0 RI C H A R D A D A M S E N G I N E E R S 55 0 7 E B U S C H B L V D TA M P A , F L 3 3 6 1 7 81 3 . 9 8 5 . 4 6 0 0 VE N T U R E M E C H A N I C A L I N C . 16 4 4 W C R O S B Y R O A D CA R R O L L T O N , T X 7 5 0 0 6 97 2 . 8 7 1 . 1 3 0 0 HU R S T E L E C T R I C C O . 22 9 W . H U R S T B L V D . HU R S T , T X 7 6 0 5 3 81 7 . 2 6 8 . 3 0 0 0 TB D PR O J E C T AR C O / M U R R A Y D E S I G N B U I L D 49 2 5 G R E E N V I L L E A V E # 9 1 5 DA L L A S , T X 7 5 2 0 6 21 4 . 3 7 7 . 6 6 8 1 PR O J E C T S W A N S O N 36 4 2 E U L E S S - G R A P E V I N E R O A D GR A P E V I N E , T X AO S E N G I N E E R I N G 50 2 0 T E N N Y S O N P A R K W A Y PL A N O , T X 7 5 0 2 4 21 4 . 4 3 2 . 3 0 3 0 DATE : 05.08.2023 AS BUILT 12-16-24 AS BUILT AS OF 12-16-2024 #NOTES BY SYMBOL: 1. FACTORY SUPPLIED DISCONNECT SWITCH. 2. NOT NOT USED. 3. ROOFTOP WEATHERPROOF GFCI OUTLET WITH IN-USE COVER. 4. NOTE NOT USED. 5. NOTE NOT USED. 6. NOTE NOT USED.. GENERAL WAREHOUSE POWER NOTES: CITY CODES: NEC: 2005 2015 IECC A. ALL WIRING TO BE #12 AWG THHN FOR 120V CIRCUITS LESS THAN 150'. ALL WIRING TO BE #10AWG THHN FOR 120V CIRCUITS GREATER THAN 150'. B. ALL PENETRATIONS THROUGH WALLS AND CEILING TO BE FIRE CAULKED AND AIR TIGHT. C. COORDINATE ALL ROOF PENETRATIONS WITH ROOFING SUBCONTRACTOR AND G.C. PRIOR TO PENETRATING ROOF. D. CONDUIT RACKS 12" OR LESS TO BE LOCATED 1'-0" FROM SPRINKLER HEAD. CONDUIT RACKS GREATER THAN 12" TO 24" MUST BE LOCATED NO CLOSER THAN 2'-0" FORM SPRINKLER HEAD. E. HOME RUN CONDUITS TO BE LIMITED TO NO MORE THAN (6) HOT CONDUCTORS. F. ALL EQUIPMENT GROUNDING CONDUCTORS OF WIRE SIZE #6AWG AND SMALLER ARE TO HAVE A CONTINUOUS OUTER FINISH THAT IS EITHER GREEN OR GREEN WITH ONE OR MORE YELLOW STRIPES. EQUIPMENT GROUNDING CONDUCTORS OF WIRE SIZE #4AWG AND LARGER SHALL BE IDENTIFIED WITH GREEN TAPE (OR OTHER LISTED MEANS) ACCORDING TO NEC 250.119(A). G. HIGH BAY LIGHTING CONTROL: ALL HIGHBAYS TO BE CONTROLLED BY INTEGRAL OCCUPANCY SENSORS E2.00 NSCALE: 1/8" = 1'-0"01 OFFICE POWER SCALE: 1/8" = 1'-0"02 OFFICE LIGHTING