Loading...
HomeMy WebLinkAboutDFW West Logistics_Architectural OFFICE As Builts_12.18.24ABBREVIATIONS LEGEND AFF ACOU ADA ADJ ALUM ALT APPR APPROX ARCH A/E AVG BD BLVD BLKG BLDG BMD CPT CLG CT COL CONC CMU CONT CJ CORR DTL DIM DR DN DS DWG ELEC ELEV EMER EQ EQUIP EXIST EJ EXT EIFS FIN FIP FE FEC FL FT FTG GA GALV GC GL GYP HT ABOVE FINISHED FLOOR ACOUSTICAL AMERICANS WITH DISABILITIES ACT ADJACENT ALUMINUM ALTERNATE APPROVE, APPROVED APPROXIMATE ARCHITECT, ARCHITECTURAL ARCHITECT/ENGINEER AVERAGE BOARD BOULEVARD BLOCKING BUILDING BOTTOM OF METAL DECK CARPET CEILING CERAMIC TILE COLUMN CONCRETE CONCRETE MASONRY UNIT CONTINUOUS, CONTINUE CONTROL JOINT, CONSTRUCTION JOINT CORRIDOR DETAIL DIMENSION DOOR DOWN DOWNSPOUT DRAWING ELECTRIC, ELECTRICAL ELEVATION EMERGENCY EQUAL EQUIPMENT EXISTING EXPANSION JOINT EXTERIOR EXTERIOR INSULATION FINISH SYSTEM FINISH, FINISHED FOAM IN PLACE FIRE EXTINGUISHER FIRE EXTINGUISHER CABINET FLOOR, FLOORING FEET, FOOT FOOTING GAGE, GAUGE GALVANIZED GENERAL CONTRACTOR GLASS, GLAZING GYPSUM HEIGHT HM IMP IN INT JAN MAINT MAT'L MAX MECH MTL MEZZ MIN MISC MTD N/A NTS OC OPP OH PLAM PLBG PREFAB PREFIN PT QTY REF REINF REQ'D RD SCH SIM SHT SC STC SPEC SF SS STD STL STR TEMP TH TYP UNO VERT VEST VCT VWC WH W/ W/O WD HOLLOW METAL INSULATED METAL PANEL INCH INTERIOR JANITOR MAINTENANCE MATERIAL MAXIMUM MECHANIC, MECHANICAL METAL MEZZANINE MINIMUM MISCELLANEOUS MOUNTED NOT APPLICABLE NOT TO SCALE ON CENTER OPPOSITE OVERHEAD PLASTIC LAMINATE PLUMBING PREFABRICATE, PREFABRICATED PREFINISH, PREFINISHED PRESSURE TREATED QUANTITY REFERENCE REINFORCE, REINFORCED,REINFORCING REQUIRED ROOF DRAIN SCHEDULE SIMILAR SHEET SOLID CORE SOUND TRANSMISSION COEFFICIENT SPECIFICATION SQUARE FOOT, SQUARE FEET STAINLESS STEEL STANDARD STEEL STRUCTURE, STRUCTURAL TEMPORARY TEMPORARY THICK, THICKNESS TYPICAL UNLESS NOTED OTHERWISE VERTICAL VESTIBULE VINYL COMPOSITION TILE VINYL WALL COVERING WATER HEATER WITH WITHOUT WOOD SYMBOLS LEGEND SECTION PLAN TITLE DRAWING TITLEREVISION MARK SECTION NUMBER DIRECTION OF NORTH EXTENT OF CUT BETWEEN DOTS 2 5 A2.1 SCALE: 1/4"=1'-0" DWG TITLE SCALE: 1/4" = 1'-0" PLAN TITLE DIRECTION OF CUT 5 A7.1 SHEET SECTION IS SHOWN REVISION NUMBER LIST OF DRAWINGS SHEET #DESCRIPTION ARCHITECTURAL TT1.1 COVER SHEET TT1.2 COMCHECK TLS1.1 LIFE SAFETY PLAN LOCATION MAP PLUMBING BEST MANAGEMENT PRACTICES SOLID WASTE MANAGEMENT : PROVIDE DESIGNATED WASTE COLLECTION AREAS AND CONTAINERS. CLEAR SITE OF TRASH. MATERIAL DELIVERY AND STORAGE : PROVIDE A DESIGNATED MATERIAL STORAGE AREA; IF NEEDED, PROVIDE A SECOND CONTAINER CONCRETE WASTE : PROVIDE A DESIGNATED AREA TO BE USED FOR CONCRETE TRUCK WASH-OUT IF NEEDED.AT NO TIME SHALL RUN-OFF ENTER THE STORM DRAINS. TYPE / NUMBER ROOM NUMBER WINDOW NUMBER GLAZING LETTER ROOM NAME FRAME / OPENING DESIGNATION FRAME / OPENING LETTER OR NUMBER101 WINDOW DESIGNATION 01 GLAZING DESIGNATION ROOM DESIGNATION ### NAME P1WALL TYPE KEYNOTE DRAWING NOTE NUMBER PARTITION REFERENCED DETAIL DETAIL NUMBER 5 A7.1 SHEET DETAIL IS SHOWN ELEVATION SHEET ELEVATION IS SHOWN DIRECTION OF VIEW 5 A7.1 ELEVATION NUMBER PAINT & PAINTING SUPPLIES PROVIDE PROPER STORAGE, USE AND CLEANUP OF MATERIALS. VEHICLE FUELING, MAINT. AND CLEANING : PROVIDE A DESIGNATED FUELING AREA WITH A SECOND CONTAINER. HAZARDOUS WASTE MANAGEMENT: PREVENT THE DISCHARGE OF HAZARDOUS WASTE POLLUTANTS INTO THE STORM DRAIN SYSTEM. THE CONTRACTOR/OWNER SHALL IMPLEMENT BEST MANAGEMENT PRACTICES AS FOLLOWS: PROJECT DATA PROJECT DESCRIPTION 1A TT1.1 TITLE SHEET EGRESS DATA - CHAPTER 10 ALLOWABLE HEIGHT - CHAPTER 5, TABLE 504.3 ALLOWABLE BUILDING HEIGHT:75'-0", 4-STORIES ACTUAL BUILDING HEIGHT:44'-0" TOP OF PARAPET, 1-STORY (EXISTING; NO CHANGE) CONSTRUCTION TYPE - CHAPTER 6 PROPOSED:TYPE IIB STRUCTURAL FRAME : BEARING WALLS (EXTERIOR) : 0 HOURS 0 HOURS BEARING WALLS (INTERIOR) NON-BEARING WALLS : 0 HOURS 0 HOURS FLOOR CONSTRUCTION : ROOF CONSTRUCTION : 0 HOURS 0 HOURS FIRE PROTECTION SYSTEM - CHAPTER 9 FULLY SPRINKLED OCCUPANT LOADS - CHAPTER 10, TABLE 1004.5 USE GROUP RATIO USE GROUP SF OCCUPANT LOAD BUILDING CODE INFORMATION PROJECT CODE DATA USE GROUPS - CHAPTER 3 USE GROUPS: SEPARATION: B (OFFICE) UNLIMITED AREA - NON SEPARATED ALLOWABLE AREA - CHAPTER 5, TABLE 506.2 ALLOWABLE AREA:UNLIMITED AREA (SECTION 507) 2,965 SF B 1/150 SF 2,689 SF 18 PERSONS REQUIRED DOOR WIDTH : 37 X 0.2" = 7.4" PROVIDED DOOR WIDTH : 3 EXITS X 32" EA = 96" 1 EXIT X 64" EA = 64" COMMON PATH OF TRAVEL REQUIREMENT : 100' MAXIMUM TRAVEL DISTANCE : 100' BUILDING CODE: ELECTRICAL CODE: PLUMBING CODE: MECHANICAL CODE: FIRE CODE: 2021 INTERNATIONAL BUILDING CODE W/ AMENDMENTS 2020 NATIONAL ELECTRIC CODE W/ AMENDMENTS 2021 INTERNATIONAL PLUMBING CODE W/ AMENDMENTS 2021 INTERNATIONAL MECHANICAL CODE 2015 INTERNATIONAL FIRE CODE W/ AMENDMENTS ACCESSIBILITY: ENERGY CODE: 2012 TEXAS ACCESSIBILITY STANDARD | TAS | TDLR 2015 INTERNATIONAL ENERGY CONSERVATION CODE W/ AMENDMENTS NEW 2,965 SF SPECULATIVE OFFICE WITHIN A 200,340 EXISTING WAREHOUSE ACTUAL AREA: TA2.0 OVERALL PLAN TA2.1 ENLARGED OFFICE FLOOR PLAN TA2.2 ENLARGED RESTROOM FLOOR PLAN TA2.3 MILLWORK SECTIONS TA3.1 ENLARGED OFFICE RCP PLAN TA3.2 CEILING DETAILS TA4.1 DOOR SCHEDULE AND DETAILS TA4.2 PARTITION DETAILS TA4.3 PARTITION TYPES TA5.1 EXTERIOR OFFICE ELEVATIONS TA6.1 SECTIONS TA10.1 FINISH SPECIFICATIONS TA10.2 OFFICE FINISH FLOOR PLAN PLUMBING SYSTEMS - CHAPTER 29, 2902.1 PLAN BACKGROUND GRAPHICS ALL PLAN BACKGROUND FEATURES SUCH AS RACKING, EQUIPMENT, FURNITURE, ETC. ARE LIGHTENED ON THE FLOOR PLANS AND ARE SHOWN FOR COORDINATION PURPOSES ONLY. THEY ARE NOT TO BE CONSIDERED A PART OF THIS PERMIT NOR SHALL THEY BE USED FOR FIELD DIMENSIONING (SCALING). P0.1 COVER SHEET SYMBOLS AND NOTES P2.1 PLUMBING FLOOR PLAN P3.1 PLUMBING DETAILS P4.1 PLUMBING SCHEDULES P5.1 PLUMBING RISERS PROJECT FOR: ARCHITECT CONTRACTOR GMA ARCHITECTS 7930 CLAYTON ROAD, SUITE 300 RICHMOND HEIGHTS, MISSOURI 63117 (P) 314.822.5191 MECHANICAL ELECTRICAL PLUMBING ARCO/ MURRAY DESIGN BUILD 4925 GREENVILLE AVENUE, SUITE 915 DALLAS, TEXAS 75206 (P) 214.377.6681 OFFICE BUILD OUT 3642 EULESS-GRAPVINE ROAD, SUITE 100 GRAPEVINE TX, 76051 SWANSON INDUSTRIAL SWANSON INDUSTRIAL VENTURE MECHANICAL INC. 1644 W CROSBY RD CARROLLTON, TX 75006 (P) 972.871.1300 HURST ELECTRIC CO. 229 W. HURST BLVD. HURST, TX 76053 (P) 817.268.3000 AOS ENGINEERING 5020 TENNYSON PARKWAY PLANO, TX 75024 (P) 214-432-3030 SHEET NUMBER JOB NO : GA1054 PA : MLK DATE : 1/8/2024 REVISIONS AR C H I T E C T CO N T R A C T O R CO N S U L T I N G E N G I N E E R S EL E C T R I C A L : PL U M B I N G : ME C H A N I C A L : 79 3 0 C L A Y T O N R D . S T E 3 0 0 RI C H M O N D , H E I G H T S 6 3 1 1 7 (P ) 3 1 4 - 8 2 2 - 5 1 9 1 WW W . G M A - A R C H I T E C T S . C O M THIS DESIGN AND THESE DRAWINGS ARE THE PROPERTY OF GMA ARCHITECTS, INC. NO PART OF THIS WORK MAY BE REPRODUCED WITHOUT PRIOR WRITTEN PERMISSION FROM GMA ARCHITECTS, INC. VE N T U R E M E C H A N I C A L I N C . 16 4 4 W C R O S B Y R O A D CA R R O L L T O N , T X 7 5 0 0 6 97 2 . 8 7 1 . 1 3 0 0 HU R S T E L E C T R I C C O . 22 9 W . H U R S T B L V D . HU R S T , T X 7 6 0 5 3 81 7 . 2 6 8 . 3 0 0 0 PR O J E C T AR C O / M U R R A Y D E S I G N B U I L D 49 2 5 G R E E N V I L L E A V E # 9 1 5 DA L L A S , T X 7 5 2 0 6 21 4 . 3 7 7 . 6 6 8 1 PR O J E C T S W A N S O N 36 4 2 E U L E S S - G R A P E V I N E R O A D , S U I T E 1 0 0 GR A P E V I N E , T X AO S E N G I N E E R I N G 50 2 0 T E N N Y S O N P A R K W A Y PL A N O , T X 7 5 0 2 4 21 4 . 4 3 2 . 3 0 3 0 FOR RECORD SET 12.18.2024 WATER LAVATORIES SERVICEDRINKING MEN - 19CLASSIFICATION: B OCCUPANTS: 37 1 PER 100 = 0.37 1 PER 25 (1ST 50) = 0.76 1 PER 40 (1ST 80) = 0.475 WOMEN - 18 MENSUBTOTALSWOMEN 0.76 0.475 0.37 MEN WOMEN REQUIRED TOTALS TOTAL PROVIDED 1 1 CLOSETS FOUNTAINS SINKS 0.72 0.450 1 1 1 1 4 4 1 1 1 1 PER 40 (1ST 80) = 0.450 UNISEX 1 1 PER 25 (1ST 50) = 0.72 B 1/15 SF 276 SF 19 PERSONS TOTAL 2,965 SF 37 PERSONS MECHANICAL M101 OVERALL FLOOR PLAN - MECHANICAL M102 OVERALL ROOF PLAN - MECHANICAL M401 ENLARGED SPEC - OFFICE FLOOR PLAN - MECHANICAL M402 ENLARGED SPEC - OFFICE ROOF PLAN - MECHANICAL M601 MECHANICAL SCHEDULES ELECTRICAL E0.00 ELECTRICAL SPECS AND SYMBOLS E0.01 ELECTRICAL COMCHECK E2.00 OVERALL WAREHOUSE E2.01 OFFICE ELECTRICAL ELECTRIC CODE:2020 NATIONAL ELECTRICAL CODE (NFPA 70) REGARDING ELECTRICAL VEHICLE CHARGING STATIONS FUEL GAS CODE: 2021 INTERNATIONAL FUEL GAS CODE STRUCTURAL TS1.0 ROOF FRAMING DETAILS TT1.2 COMCHECK SHEET NUMBER JOB NO : GA1054 PA : MLK DATE : 1/8/2024 REVISIONS AR C H I T E C T CO N T R A C T O R CO N S U L T I N G E N G I N E E R S EL E C T R I C A L : PL U M B I N G : ME C H A N I C A L : 79 3 0 C L A Y T O N R D . S T E 3 0 0 RI C H M O N D , H E I G H T S 6 3 1 1 7 (P ) 3 1 4 - 8 2 2 - 5 1 9 1 WW W . G M A - A R C H I T E C T S . C O M THIS DESIGN AND THESE DRAWINGS ARE THE PROPERTY OF GMA ARCHITECTS, INC. NO PART OF THIS WORK MAY BE REPRODUCED WITHOUT PRIOR WRITTEN PERMISSION FROM GMA ARCHITECTS, INC. VE N T U R E M E C H A N I C A L I N C . 16 4 4 W C R O S B Y R O A D CA R R O L L T O N , T X 7 5 0 0 6 97 2 . 8 7 1 . 1 3 0 0 HU R S T E L E C T R I C C O . 22 9 W . H U R S T B L V D . HU R S T , T X 7 6 0 5 3 81 7 . 2 6 8 . 3 0 0 0 PR O J E C T AR C O / M U R R A Y D E S I G N B U I L D 49 2 5 G R E E N V I L L E A V E # 9 1 5 DA L L A S , T X 7 5 2 0 6 21 4 . 3 7 7 . 6 6 8 1 PR O J E C T S W A N S O N 36 4 2 E U L E S S - G R A P E V I N E R O A D , S U I T E 1 0 0 GR A P E V I N E , T X AO S E N G I N E E R I N G 50 2 0 T E N N Y S O N P A R K W A Y PL A N O , T X 7 5 0 2 4 21 4 . 4 3 2 . 3 0 3 0 FOR RECORD SET 12.18.2024 OFFICE LIFE SAFETY PLAN3 TLS1.1 SCALE: 1/4" = 1'-0" 106 UNISEX RR 105 UNISEX RR 104 JANITOR 103 OPEN OFFICE 107 BREAKROOM 108 UNISEX RR 109 UNISEX RR 110 IT CLOSET TR A V E L D I S T A N C E = 5 3 ' - 0 " T O E X I T FE C QP 1 EXIT BRAILLE NOTE 1: THE INTERNATIONAL SYMBOL OF ACCESSIBILITY SHALL BE THE STANDARD USED TO IDENTIFY FACILITIES THAT ARE ACCESSIBLE TO AND USABLE BY PHYSICALLY DISABLED PERSONS AS SET FORTH IN THE AMERICAN WITH DISABILITIES ACT (ADA). 4" 6" NOTE 2: WHERE PERMANENT IDENTIFICATION IS PROVIDED FOR ROOMS AND SPACES. SIGNS SHALL BE INSTALLED ON THE WALL ADJACENT TO THE LATCH SIDE OF THE DOOR. WHERE THERE IS NO WALL SPACE TO THE LATCH SIDE OF THE DOOR, INCLUDING AT DOUBLE LEAF DOORS, SIGNS SHALL BE PLACED ON THE NEAREST ADJACENT WALL. MOUNTING HEIGHT SHALL BE 60" TO THE CENTERLINE OF THE SIGN ABOVE FINISHED FLOOR. EGRESS WALL SIGNS EXIT & ENTRANCE SIGNAGE WITH BRAILLE OTHER WALL SIGNS GENERAL NOTES TACTILE EXIT SIGN: "EXIT". EVENLIGHT SOVEREIGN II OR SIMILAR. SIGNAGE KEYNOTES ALL EGRESS ILLUMINATION SHALL COMPLY WITH 2021 IBC SECTION 1006. THE MEANS OF EGRESS ILLUMINATION LEVEL SHALL NOT BE LESS THAN 1 FOOT-CANDLE AT THE WALKING SURFACE LEVEL. SEE ELEC. DWGS. FOR EGRESS ILLUMINATION COMPLIANCE. FINAL LAYOUT OF WAREHOUSE EXIT SIGNS & FIRE EXTINGUISHERS TO BE COORDINATED W/ LOCAL FIRE MARSHALL. PROVIDE TACTILE EXIT SIGNS IN COMPLIANCE W/ SECTION 1013 OF 2021 IBC. 1. 2. 3. EXIT DOORS SHALL BE OPERABLE FROM THE INSIDE WITHOUT THE USE OF A KEY OR SPECIAL KNOWLEDGE OF EFFORT. 4. ADDITIONAL EXIT SIGNS AND/OR EMERGENCY LIGHTING MAY BE REQUIRED, SUBJECT TO FIELD INSPECTION & DETERMINATION OF THE AUTHORITY HAVING JURISDICTION. 5. 1 LIFE SAFETY LEGEND EXIT WIDTH PROVIDED IN INCHES TRAVEL DISTANCE TO PRIMARY EXIT 36 EXIT SYMBOL 55' =EXIT SIGN =FIRE EXTINGUISHER, MOUNTED NO HIGHER THAN 3'-6" AFF TO TOP OF FIRE EXTINGUISHER. VERIFY FINAL LOCATIONS WITH LOCAL FIRE MARSHALL FE ALL PLAN BACKGROUND FEATURES SUCH AS RACKING, EQUIPMENT, FURNITURE, ETC. ARE LIGHTENED ON THE FLOOR PLANS AND ARE SHOWN FOR COORDINATION PURPOSES ONLY. THEY ARE NOT TO BE CONSIDERED A PART OF THIS PERMIT NOR SHALL THEY BE USED FOR FIELD DIMENSIONING (SCALING). 6. TRAVEL DISTANCE = 77'-3" TO EXIT A B C D E F G H J K L M N P 1 2 3 4 5 6 Q NOT IN SCOPE KEY PLAN SCALE: NTS 6 AREA OF WORK 5/8" GYP. BD. SEMI-RECESSED FIRE EXTINGUISHER CABINET MAINTAIN RATED PARTITION AROUND CABINET AS REQ'D. COORDINATE DEPTH OF CABINET W/ PARTITION THICKNESS 2 TLS1.1 SCALE: N.T.S. FIRE EXTINGUISHER CABINET 2-1/2" MAX. R. O . P E R M F R . 4' - 0 " A . F . F SEE PLAN FOR PARTITION TYPES 1 TLS1.1 SCALE: N.T.S. FIRE EXTINGUISHER CABINET FIRE EXT. CABINET SHIM AS REQUIREDSEMI-RECCESSED FIRE EXTINGUISHER CABINET SEMI-RECCESSED TLS1.1 LIFE SAFETY PLAN SHEET NUMBER JOB NO : GA1054 PA : MLK DATE : 1/8/2024 REVISIONS AR C H I T E C T CO N T R A C T O R CO N S U L T I N G E N G I N E E R S EL E C T R I C A L : PL U M B I N G : ME C H A N I C A L : 79 3 0 C L A Y T O N R D . S T E 3 0 0 RI C H M O N D , H E I G H T S 6 3 1 1 7 (P ) 3 1 4 - 8 2 2 - 5 1 9 1 WW W . G M A - A R C H I T E C T S . C O M THIS DESIGN AND THESE DRAWINGS ARE THE PROPERTY OF GMA ARCHITECTS, INC. NO PART OF THIS WORK MAY BE REPRODUCED WITHOUT PRIOR WRITTEN PERMISSION FROM GMA ARCHITECTS, INC. VE N T U R E M E C H A N I C A L I N C . 16 4 4 W C R O S B Y R O A D CA R R O L L T O N , T X 7 5 0 0 6 97 2 . 8 7 1 . 1 3 0 0 HU R S T E L E C T R I C C O . 22 9 W . H U R S T B L V D . HU R S T , T X 7 6 0 5 3 81 7 . 2 6 8 . 3 0 0 0 PR O J E C T AR C O / M U R R A Y D E S I G N B U I L D 49 2 5 G R E E N V I L L E A V E # 9 1 5 DA L L A S , T X 7 5 2 0 6 21 4 . 3 7 7 . 6 6 8 1 PR O J E C T S W A N S O N 36 4 2 E U L E S S - G R A P E V I N E R O A D , S U I T E 1 0 0 GR A P E V I N E , T X AO S E N G I N E E R I N G 50 2 0 T E N N Y S O N P A R K W A Y PL A N O , T X 7 5 0 2 4 21 4 . 4 3 2 . 3 0 3 0 FOR RECORD SET 12.18.2024 A B C D E F G H J K L M N P 1 2 3 4 5 6 Q OVERALL PLAN1 TA2.0 SCALE: 1" = 30'-0" 3 TA2.1 SEE SHELL DRAWING FOR MORE INFO TA2.0 OVERALL PLAN SHEET NUMBER JOB NO : GA1054 PA : MLK DATE : 1/8/2024 REVISIONS AR C H I T E C T CO N T R A C T O R CO N S U L T I N G E N G I N E E R S EL E C T R I C A L : PL U M B I N G : ME C H A N I C A L : 79 3 0 C L A Y T O N R D . S T E 3 0 0 RI C H M O N D , H E I G H T S 6 3 1 1 7 (P ) 3 1 4 - 8 2 2 - 5 1 9 1 WW W . G M A - A R C H I T E C T S . C O M THIS DESIGN AND THESE DRAWINGS ARE THE PROPERTY OF GMA ARCHITECTS, INC. NO PART OF THIS WORK MAY BE REPRODUCED WITHOUT PRIOR WRITTEN PERMISSION FROM GMA ARCHITECTS, INC. VE N T U R E M E C H A N I C A L I N C . 16 4 4 W C R O S B Y R O A D CA R R O L L T O N , T X 7 5 0 0 6 97 2 . 8 7 1 . 1 3 0 0 HU R S T E L E C T R I C C O . 22 9 W . H U R S T B L V D . HU R S T , T X 7 6 0 5 3 81 7 . 2 6 8 . 3 0 0 0 PR O J E C T AR C O / M U R R A Y D E S I G N B U I L D 49 2 5 G R E E N V I L L E A V E # 9 1 5 DA L L A S , T X 7 5 2 0 6 21 4 . 3 7 7 . 6 6 8 1 PR O J E C T S W A N S O N 36 4 2 E U L E S S - G R A P E V I N E R O A D , S U I T E 1 0 0 GR A P E V I N E , T X AO S E N G I N E E R I N G 50 2 0 T E N N Y S O N P A R K W A Y PL A N O , T X 7 5 0 2 4 21 4 . 4 3 2 . 3 0 3 0 FOR RECORD SET 12.18.2024 ENLARGED OFFICE FLOOR PLAN2 TA2.1 SCALE: 1/4" = 1'-0" 106 UNISEX RR 105 UNISEX RR 104 JANITOR 103 OPEN OFFICE 107 BREAKROOM 108 UNISEX RR 109 UNISEX RR 110 IT CLOSET 106 105 104 109 110108 103A 103B 107B 107A EX 103 1 TA2.2 35'-3 3/4" P 3' - 1 1 1 / 2 " 5' - 3 1 / 4 " 10 3 / 4 " 10 3 / 4 " 1'-4"1'-10"5'-0"5'-0"2'-6 3/4" 2' - 6 3 / 4 " 5' - 0 " 1' - 1 1 1 / 4 " 15 ' - 2 " 16'-2 1/8" 11'-0"3'-4 1/2"1'-11 5/8" 2' - 0 " 2'-1" 8' - 9 " 2'-0" FINISH END PANEL SS-1, SCHEDULED COUNTERTOP WITH 4" BACKSPLASH AND RIGHT SIDE SPLASH PL-1, PLASTIC LAMINATE BASE CABINET, NO SHELF. ATTACHED BASE, AT SINK CABINET, ONLY PL-1, PLASTIC LAMINATE BASE CABINET WITH (1) DRAWER AND (1)ADJUSTABLE SHELF WITH BLACK MELAMINE INTERIOR PL-1, PLASTIC LAMINATE UPPER CABINET, 12" DEEP WITH (2) ADJ. SHELVES AND BLACK MELAMINE INTERIOR 11'-0" REF 2'-0"2'-0"3'-0"2'-0"2'-0" 3'-4 1/2"1'-11 5/8" 3'-6" 3'-6" FINISH END PANEL PL-1, PLASTIC LAMINATE BASE 2' - 1 0 " 1' - 8 " 3' - 0 " 3'-4" 8 7/8" 8' - 1 3 / 4 " 9' - 9 " TA2.23 BREAKROOM MILLWORK ELEVATION1 TA2.1 SCALE: 1/4" = 1'-0" COPY MILLWORK ELEVATION3 TA2.1 SCALE: 1/4" = 1'-0" TA2.2 1 1"2'-2"2'-2"2'-2"2'-2" 8'-9" FINISH END PANEL SS-1, SCHEDULED COUNTERTOP WITH 4" BACKSPLASH AND RIGHT SIDE SPLASHPL-1, PLASTIC LAMINATE BASE CABINET WITH (1) DRAWER AND (1)ADJUSTABLE SHELF WITH BLACK MELAMINE INTERIOR PL-1, PLASTIC LAMINATE UPPER CABINET, 12" DEEP WITH (2) ADJ. SHELVES AND BLACK MELAMINE INTERIOR 2' - 1 0 " 1' - 8 " 3' - 0 " PL-1, PLASTIC LAMINATE BASE 4 TA2.3 4 TA2.3 2 TA2.3 3 TA2.3 1 TA2.3 COPY P1 P1 P1 P1 P1 P1 P1 P1 P5 P5 P3 P3 P3 P3 P3 P3 P3 Q 6 7 2 5 3 4 1 8 5 5 5 5 9 9 9 99 9 3'-4"2'-10"1'-6" 8 7/8" 3'-4"8 7/8" 3' - 4 " 4' - 4 3 / 8 " 3' - 4 " 5' - 8 1 / 8 " 3'-4"2'-10" FLOOR PLAN KEY NOTES 1 JANITOR SINK, VERIFY WITH G.C., AT THIS LOCATION. ADD FRP WALL PROTECTION 4'-0" HIGH ON WET WALLS. RE: FINISH PLAN OWNER PROVIDED REFRIGERATOR WITH ICE MAKER, PROVIDE ELECTRICAL/ WATER CONNECTIONS AS NECESSARY. REFER TO ELECTRICAL AND PLUMBING DRAWINGS ACCESSIBLE DRINKING FOUNTAIN, RE: TO PLUMBING DRAWINGS AND DRINKING FOUNTAIN DETAIL ON SHEET TA2.2 OWNER PROVIDED COPY MACHINE, VERIFY POWER REQUIREMENTS PRIOR TO CONSTRUCTION OWNER PROVIDED FURNITURE, VERIFY ELECTRICAL REQUIREMENTS AND DATA REQUIREMENTS PRIOR TO CONSTRUCTION PROVIDE WATER LINE FOR OWNER PROVIDED COFFEE MACHINE, VERIFY REQUIREMENTS PRIOR TO CONSTRUCTION, COORDINATE WITH ELEVATIONS OWNER PROVIDED MICROWAVES, VERIFY PROPER ELECTRICAL REQUIREMENTS PRIOR TO CONSTRUCTION PROVIDE 10 GALLON WATER HEATER MOUNTED ON RACK AFF. SEE MEP DRAWINGS FOR MORE INFORMATION. SECOND FLOOR SPANDREL GLASS. SEE DETAILS 1/TA6.1 AND 2/TA6.1 GENERAL FLOOR PLAN NOTES 1.CONTRACTOR TO VERIFY ALL DIMENSIONS AND CONDITIONS SHOWN ON THE DRAWINGS AT THE JOB SITE AND NOTIFY ARCHITECT OF ANY OMISSIONS, DISCREPANCIES, AND/OR CONFLICTS BEFORE PROCEEDING WITH THE WORK. 2.EQUIPMENT SUPPLIERS SHALL FIELD VERIFY ALL DIMENSIONS PRIOR TO FABRICATION. 3.USE TAPEABLE METAL CORNER BEADS AT ALL GYPSUM BOARD CORNERS. 4.DOORS SHOWN ADJACENT TO WALLS ARE TYPICALLY 4" FROM ADJACENT UNLESS NOTED OTHERWISE. 5.ALL DIMENSIONS ARE TO FACE OF PARTITIONS. 6.FIRE RETARDANT BLOCKING SHALL BE PROVIDED IN ALL WALLS AS REQUIRED BY CODE AND AS REQUIRED / RECOMMENDED FOR THE SUPPORT OF MILLWORK, TOILET PARTITIONS AND ACCESSORIES, ETC. 7.PROVIDE MOISTURE RESISTANT GYPSUM BOARD AT ALL WALLS. 8.EXPOSED CONCRETE FLOOR JOINTS SHALL BE FILLED WITH MM80 SEMI-RIGID JOINT SEALANT OR EQUAL. 9.ALL INTERIOR OFFICE WALLS, STEEL GIRTS AND BRACING SHALL BE PAINTED. 10.PROVIDE ACCESS PANELS AS REQUIRED, COORDINATE WITH M.E.P. & F.P. 11.COORDINATE FIRE EXTINGUISHERS LOCATIONS WITH ARCHITECT AND LOCAL FIRE MARSHALL. LOCATIONS SHALL FOLLOW NFPA 472, FM STANDARDS, AND ADA GUIDELINES. SEE DETAILS 1/TLS1.1 & 2/TLS1.1. 12.PROVIDE ROOM NAME SIGNAGE FOR MEN'S AND WOMEN'S RESTROOMS. INCLUDE INTERNATIONAL SYMBOL OF ACCESSIBILITY. SIGNAGE SHALL BE A.D.A. COMPLIANT. PROVIDE EXAMPLES TO ARCHITECT. SEE SHEET TLS1.1 13.DOORS DIMENSIONED TO FACE OF JAMB. 14 ROOF INSULATION ABOVE OFFICE LOCATIONS TO BE R-25 3 4 5 6 7 8 2 9 GENERAL FLOOR PLAN LEGEND NEW WALL EXISTING WALL TO REMAIN FUTURE WALL EXISTING DOOR TO REMAIN NEW WALL A B C D E F G H J K L M N P 1 2 3 4 5 6 Q NOT IN SCOPE KEY PLAN SCALE: NTS 6 AREA OF WORK TA2.1 ENLARGED OFFICE FLOOR PLAN SHEET NUMBER JOB NO : GA1054 PA : MLK DATE : 1/8/2024 REVISIONS AR C H I T E C T CO N T R A C T O R CO N S U L T I N G E N G I N E E R S EL E C T R I C A L : PL U M B I N G : ME C H A N I C A L : 79 3 0 C L A Y T O N R D . S T E 3 0 0 RI C H M O N D , H E I G H T S 6 3 1 1 7 (P ) 3 1 4 - 8 2 2 - 5 1 9 1 WW W . G M A - A R C H I T E C T S . C O M THIS DESIGN AND THESE DRAWINGS ARE THE PROPERTY OF GMA ARCHITECTS, INC. NO PART OF THIS WORK MAY BE REPRODUCED WITHOUT PRIOR WRITTEN PERMISSION FROM GMA ARCHITECTS, INC. VE N T U R E M E C H A N I C A L I N C . 16 4 4 W C R O S B Y R O A D CA R R O L L T O N , T X 7 5 0 0 6 97 2 . 8 7 1 . 1 3 0 0 HU R S T E L E C T R I C C O . 22 9 W . H U R S T B L V D . HU R S T , T X 7 6 0 5 3 81 7 . 2 6 8 . 3 0 0 0 PR O J E C T AR C O / M U R R A Y D E S I G N B U I L D 49 2 5 G R E E N V I L L E A V E # 9 1 5 DA L L A S , T X 7 5 2 0 6 21 4 . 3 7 7 . 6 6 8 1 PR O J E C T S W A N S O N 36 4 2 E U L E S S - G R A P E V I N E R O A D , S U I T E 1 0 0 GR A P E V I N E , T X AO S E N G I N E E R I N G 50 2 0 T E N N Y S O N P A R K W A Y PL A N O , T X 7 5 0 2 4 21 4 . 4 3 2 . 3 0 3 0 FOR RECORD SET 12.18.2024 GENERAL RESTROOM NOTES 1.SEE PLUMBING DRAWINGS FOR FIXTURE SPECIFICATIONS. 2.ALL EQUIPMENT SHALL BE LOCATED WITHIN REQUIRED ADA REACH RANGES 3.DO NOT LOCATE ANY FIXTURE BEHIND GRAB BARS. 4.SEE STANDARD LAV DETAILS ON THIS SHEET FOR REQUIRED CLEARANCE. 5.ALL FAUCET CONTROLS AND OPERATING MECHANISMS SHALL BE OPERABLE WITH ONE HAND AND SHALL NOT REQUIRE TIGHT GRASPING, PINCHING, OR TWISTING OF WRIST. FORCE REQUIRED TO ACTIVATE CONTROLS SHALL NOT BE GREATER THAN 5LBF 6.WATER CLOSET SEATS SHALL BE ELONGATED TYPE AND EITHER OF THE OPEN FRONT TYPE OR HAVE AN AUTOMATIC SEAT COVER DISPENSER. SEE PLUMBING DRAWINGS. 7.RESTROOM WALLS SHALL HAVE A SMOOTH, HARD NON-ABSORBENT SURFACE. 8.RESTROOM FLOORS SHALL HAVE A SMOOTH, HARD NON-ABSORBENT AND SLIP RESISTANT SURFACE SUCH AS CONCRETE, TILE OR OTHER APPROVED MATERIAL AND EXTENDS 4" ONTO THE WALL. 9.ALL RESTROOMS INCLUDED IN THIS SET OF DRAWINGS FULLY COMPLY WITH ADA ACCESSIBILITY STANDARDS AND SUBJECT TO FIELD VERIFICATION. ACCESSIBLE TOUCHLESS WALL MOUNTED LAVATORY, SEE PLUMBING DWGS FOR FIXTURE TYPE ACCESSIBLE TOUCHLESS WALL MOUNTED FLUSH VALVE WATER CLOSET, SEE PLUMBING DWGS. FOR FIXTURE TYPE SURFACE MOUNTED SOAP DISPENSER, BOBRICK #B-2111 HC GRAB BARS, EQUIVALENT TO BOBRICK #B-6806 36" LG BACK OF TOILET, 42" LG ADJACENT TO TOILET 12" OFF BACK WALL, 18" L VERTICAL GRAB BAR MTD 39 TO 41" AFF AND 39" TO 41" OFF BACK WALL. SURFACE MOUNTED MULTI-ROLL TOILET TISSUE DISPENSER, BOBRICK #B-4288 SURFACE MOUNTED SANITARY NAPKIN DISPOSAL, BOBRICK #B-270 RECESSED TRASH RECEPTACLE, BOBRICK #B-43644 WITH RECESSED, AUTOMATED GEORGIA PACIFIC-ENMOTION, TOUCHLESS, BATTERY OPERATED PAPER TOWEL DISPENSER (ITEM #59466) ABOVE, STAINLESS FINISH. 24" X 48"H MIRROR, BOBRICK #B-290 HIGH-LOW WATER FOUNTAIN WITH BOTTLE FILLER 60" WIDE X 56" DEEP MINIMUM CLEARANCE AT WATER CLOSET 5'-0" DIA. WHEELCHAIR TURNING DIAMETER. 30" X 48" CLEAR FLOOR SPACE 1 2 3 4 5 6 7 8 9 10 11 RESTROOM EQUIP LEGEND (ALL KEY NOTES MAY NOT BE PRESENT ON EACH SHEET) 12 ENLARGED RESTROOM PLANS1 TA2.2 SCALE: 3/8" = 1'-0" 16"-18" 6'-2 7/8"1'-6" 2' - 1 0 " M A X 1 8 4 2 5 6 CL CL 7'-8 7/8" RESTROOM ELEVATION2 TA2.2 SCALE: 3/8" = 1'-0" 2' - 1 0 " M A X 1'-6" CL 6'-2 7/8" 16"-18" CL 7'-8 7/8" 1'-6" CL 16"-18" CL4'-4 5/8" 7'-7 3/4" 2' - 1 0 " M A X 16"-18" 4'-4 5/8"1'-6" 2' - 1 0 " M A X CL CL 7'-7 3/4" 34 " M A X T O T O P OF R I M O F S I N K 29 " C L R 40 " M A X T O BO T T O M O F RE F L E C T I V E SU R F A C E 1 5 " M I N . TO O U T L E T . M U S T B E BE L O W GR A B B A R 2' - 1 0 " 39 " - 4 1 " 16"-18" 17 " - 1 9 " TO T O P OF TO I L E T SE A T 6"3'-0" 39"-41" 12" MAX. 42" MIN. 7"-9" 4'-6" MIN. 1' - 6 " MI N . 2" M I N . 4 2 4 5 8 6 2 1 MANUAL FLUSH VALVE TO BE ON OPEN SIDE OF ROOM 3 3' - 4 " 7 CL STANDARD MOUNTING HEIGHT SCHEDULE 12" MIN. 24" MIN. 29" CLEAR AT FRONT OF SINK WRAP ALL EXPOSED PIPES 29 " M I N . 27 " M I N . 34 " M A X . *NOTE: IF A MINIMUM 9 INCHES HEIGHT OF TOE CLEARANCE IS PROVIDED A MAXIMUM OF 6 INCHES OF THE 48 INCHES CLEAR FLOOR SPACE REQUIRED AT THE FIXTURE MAY EXTEND INTO THE TOE SPACE. 6" MAX.8" MIN. 17" MIN. 18 " M I N . TO ℄ 17" MIN. 30 " M I N . 48" MIN. 19" MAX.TOE CLEARANCEKNEE CLEARANCE SIDE ELEVATION PLAN VIEW THESE DIAGRAMS ILLUSTRATE THE SPECIFIC REQUIREMENTS OF THESE REGULATIONS AND ARE INTENDED ONLY AS AN AID FOR BUILDING DESIGN AND CONSTRUCTION. CLEAR FLOOR SPACE9" M I N . STANDARD LAVATORY CLEARANCE (N.T.S) DRINKING FOUNTAIN DETAIL 39 1 / 2 " M A X . 27 " M A X CL E A R MAX.6" 36 " M A X . THIS DIAGRAM ILLUSTRATES THE SPECIFIC REQUIREMENTS OF THESE REGULATIONS AND IS INTENDED ONLY AS AN AID FOR BUILDING DESIGN AND CONSTRUCTION. STANDARD HEIGHT DRINKING FOUNTAIN ACCESSIBLE DRINKING FOUNTAIN MAX.15"MAX.15"5"5" STANDARD HEIGHT E.D.F. ACCESSIBLE E.D.F. MA X . ACCESSIBLE BOTTLE FILLER MA X . ACCESSIBLE BOTTLE FILLER 36 " T O C O N T R . 36 " T O C O N T R . RESTROOM ELEVATION3 TA2.2 SCALE: 3/8" = 1'-0" RESTROOM ELEVATION5 TA2.2 SCALE: 3/8" = 1'-0" RESTROOM ELEVATION4 TA2.2 SCALE: 3/8" = 1'-0" 8 7/8"1'-1 3/4"4" 8' - 4 1 / 8 " 9' - 9 " 4"2'-7 1/2"8 7/8" 1' - 8 3 / 8 " 8' - 0 5 / 8 " 8' - 6 1 / 8 " 22 2 1 1 1 44 4 7 7 33 8 88 5 6 5 6 5 6 6' - 0 " 4' - 0 " 4' - 0 " 7 7 6' - 0 " FRP-1, ON ALL WALLS FRP-1, ON ALL WALLS WT-1, 6' AFF ON ALL WALLS WT-1, 6' AFF ON ALL WALLS P-1, PAINT P-1, PAINTP-1, PAINT P-1, PAINT TA2.24 TA2.25 TA2.2 2 TA2.2 3 108 UNISEX RR 109 UNISEX RR 105 UNISEX RR 106 UNISEX RR 106 105 109108 2 22 2 11 7 7 7 7 11 5 6 5 6 4 3 3 4 5 6 8 8 9 10 11 12 12 8 3 3 8 6 5 44 10 12 11 12 10 1212 1111 10 P4 P3 P3 P3 P3 P3 P5 P5 P5 P3 P3 P4 B-1, VINYL BASEB-1, VINYL BASE 3 3 3'-4"4'-7"3'-4"4'-11 1/4" 3'-4"2'-3 5/8"3'-4"2'-8 1/2"3'-0 3/8" 1'-9 1/8" CL 1'-9 1/8" CL 4"4" TA2.2 ENLARGED RESTROOM FLOOR PLANS SHEET NUMBER JOB NO : GA1054 PA : MLK DATE : 1/8/2024 REVISIONS AR C H I T E C T CO N T R A C T O R CO N S U L T I N G E N G I N E E R S EL E C T R I C A L : PL U M B I N G : ME C H A N I C A L : 79 3 0 C L A Y T O N R D . S T E 3 0 0 RI C H M O N D , H E I G H T S 6 3 1 1 7 (P ) 3 1 4 - 8 2 2 - 5 1 9 1 WW W . G M A - A R C H I T E C T S . C O M THIS DESIGN AND THESE DRAWINGS ARE THE PROPERTY OF GMA ARCHITECTS, INC. NO PART OF THIS WORK MAY BE REPRODUCED WITHOUT PRIOR WRITTEN PERMISSION FROM GMA ARCHITECTS, INC. VE N T U R E M E C H A N I C A L I N C . 16 4 4 W C R O S B Y R O A D CA R R O L L T O N , T X 7 5 0 0 6 97 2 . 8 7 1 . 1 3 0 0 HU R S T E L E C T R I C C O . 22 9 W . H U R S T B L V D . HU R S T , T X 7 6 0 5 3 81 7 . 2 6 8 . 3 0 0 0 PR O J E C T AR C O / M U R R A Y D E S I G N B U I L D 49 2 5 G R E E N V I L L E A V E # 9 1 5 DA L L A S , T X 7 5 2 0 6 21 4 . 3 7 7 . 6 6 8 1 PR O J E C T S W A N S O N 36 4 2 E U L E S S - G R A P E V I N E R O A D , S U I T E 1 0 0 GR A P E V I N E , T X AO S E N G I N E E R I N G 50 2 0 T E N N Y S O N P A R K W A Y PL A N O , T X 7 5 0 2 4 21 4 . 4 3 2 . 3 0 3 0 FOR RECORD SET 12.18.2024 FLEL BASE CABINET SECTION w/ 6" DRAWER1 TA2.3 SCALE: 3/4" = 1'-0" 2'-0" 1 1 / 2 " 2' - 1 0 " PARTITION TYPE AS SCHED. BACKSPLASH WHERE OCCURS, SEE ELEVATIONS COUNTERTOP AS SCHED. AL I G N 6" DRAWER ON FULL EXTENT SLIDES MULTIPLE HOLE & PIN SUPPORTS @ MIN 2" OC SCHEDULED BASE FINISH BLACK MELAMINE INTERIOR AND (1) ADJUSTABLE SHELF SCHEDULED CABINET FINISH 4" FLEL BASE CABINET SECTION - DOOR2 TA2.3 SCALE: 3/4" = 1'-0" 2'-0" 1 1 / 2 " 2' - 1 0 " PARTITION TYPE AS SCHED. BACKSPLASH WHERE OCCURS, SEE ELEVATIONSCOUNTERTOP AS SCHED. AL I G N MULTIPLE HOLE & PIN SUPPORTS @ MIN 2" OC SCHEDULED BASE FINISH BLACK MELAMINE INTERIOR AND (1) ADJUSTABLE SHELF SCHEDULED CABINET FINISH 4" SCHEDULED CABINET PULL 4" FLEL DISPOSAL & INSULATED HW & DRAIN PIPING AS SCHED. BASE CABINET W/ SINK & GARBAGE DISPOSAL3 TA2.3 SCALE: 3/4" = 1'-0" PARTITION TYPE AS SCHED. BACKSPLASH WHERE OCCURS, SEE ELEVATIONS 2'-0" CL 8" MIN, TAS AL I G N APRON PANEL W / PLAIN FINISH COUNTERTOP AS SCHED. BASE CABINET WITH SCHEDULED FINISH CLEARANCE UNDER SINK COMPLYING W / TAS: MIN 2'-5" AFF @ APRON , 2'-3" AFF X 8" D @ KNEE SPACE , 9" AFF X 11"D @ TOE SPACE SINK W / REAR DRAIN AND FAUCET AS SCHED. PLASTIC LAMINATE TOE KICK BASE ATTACHED TO PLASTIC LAMINATE BASE CABINET DOOR PROVIDE DRAIN LINE & P-TRAP W/ PIPE PROTECTION TO MEET ACCESSIBILITY REQUIREMENTS 2' - 1 0 " 4" 1 1 / 2 " 11" MIN, TAS 9" , AD A 4" SCHEDULED CABINET PULL SCHEDULED CABINET PULL SE E E L E V A T I O N S 1'-0" CLEAR INSIDE (2) ADJUSTABLE SHELVES & BLACK MELAMINE INTERIOR SCHEDULED FINISH ON FACE OF CABINET SCHEDULED CABINET PULL MULTIPLE HOLE & PIN SUPPORTS @ MIN 2" OC 4 TA2.3 SCALE: 1 1/2" = 1'-0" UPPER CABINET SECTION HT A F F A S IN D I C A T E D TA2.3 MILLWORK SECTIONS SHEET NUMBER JOB NO : GA1054 PA : MLK DATE : 1/8/2024 REVISIONS AR C H I T E C T CO N T R A C T O R CO N S U L T I N G E N G I N E E R S EL E C T R I C A L : PL U M B I N G : ME C H A N I C A L : 79 3 0 C L A Y T O N R D . S T E 3 0 0 RI C H M O N D , H E I G H T S 6 3 1 1 7 (P ) 3 1 4 - 8 2 2 - 5 1 9 1 WW W . G M A - A R C H I T E C T S . C O M THIS DESIGN AND THESE DRAWINGS ARE THE PROPERTY OF GMA ARCHITECTS, INC. NO PART OF THIS WORK MAY BE REPRODUCED WITHOUT PRIOR WRITTEN PERMISSION FROM GMA ARCHITECTS, INC. VE N T U R E M E C H A N I C A L I N C . 16 4 4 W C R O S B Y R O A D CA R R O L L T O N , T X 7 5 0 0 6 97 2 . 8 7 1 . 1 3 0 0 HU R S T E L E C T R I C C O . 22 9 W . H U R S T B L V D . HU R S T , T X 7 6 0 5 3 81 7 . 2 6 8 . 3 0 0 0 PR O J E C T AR C O / M U R R A Y D E S I G N B U I L D 49 2 5 G R E E N V I L L E A V E # 9 1 5 DA L L A S , T X 7 5 2 0 6 21 4 . 3 7 7 . 6 6 8 1 PR O J E C T S W A N S O N 36 4 2 E U L E S S - G R A P E V I N E R O A D , S U I T E 1 0 0 GR A P E V I N E , T X AO S E N G I N E E R I N G 50 2 0 T E N N Y S O N P A R K W A Y PL A N O , T X 7 5 0 2 4 21 4 . 4 3 2 . 3 0 3 0 FOR RECORD SET 12.18.2024 ENLARGED OFFICE RCP PLAN1 TA3.1 SCALE: 1/4" = 1'-0" 106 UNISEX RR 105 UNISEX RR 104 JANITOR 107 BREAKROOM 108 UNISEX RR 109 UNISEX RR 110 IT CLOSET P GYP. BD 9'-0" AFF GYP. BD 9'-0" AFF GYP. BD 9'-0" AFF GYP. BD 9'-0" AFF GYP. BD 9'-0" AFF ACT-1 9'-0" AFF ACT-1 14'-0" AFF 1.CONTRACTOR TO REVIEW CEILING PLAN AND NOTIFY ARCH OF ANY CONFLICTS SUCH AS DUCT WORK, PIPING, ELEC., ETC. PRIOR TO PROCEEDING WITH CONSTRUCTION. 2.ALL OFFICE AREA ACOUSTICAL CEILING SHALL BE CENTERED IN EACH ROOM AS SHOWN UNLESS NOTED OTHERWISE. 3.SEE 2/TA3.2 FOR GYP. BOARD CEILING DETAIL 4.SEE LIFE SAFETY PLANS FOR EXIT SIGN LOCATIONS, THOSE SHOWN ARE FOR DESIGN INTENT ONLY AND SHOULD BE VERIFIED WITH THE LOCAL CODE OFFICIALS AND FIRE DEPARTMENT. 5.SEE ELEC. PLANS FOR FINAL LIGHTING LAYOUT. 6.SEE MECH. PLANS FOR FINAL HVAC GRILLS, DIFFUSERS, DUCTS, AIR RETURNS, ETC. LAYOUT. 7.PROVIDE MOISTURE RESISTANT GYP BOARD AT TOILET ROOM CEILINGS. 8.MATERIALS EXPOSED WITHIN DUCTS OR PLENUMS SHALL BE NONCOMBUSTIBLE OR SHALL HAVE A FLAME SPREAD INDEX NOT TO EXCEED 25 AND A SMOKE DEVELOPED INDEX NOT TO EXCEED 50, WHERE TESTED AS A COMPOSITE PRODUCT IN ACCORDANCE WITH ASTM E84 OR UL 723. 9.ACCESS PANELS TO BE LOCATED IN GYP. BOARD CEILING IN EACH RESTROOM. LOCATION TO BE DETERMINED BY ELECTRICIAN/HVAC CONTRACTOR. -SEE ELECTRICAL AND MECHANICAL DRAWINGS. GENERAL R.C.P. NOTES R.C.P. LEGEND GYP. BD. CEILING 2'-0" X 4'-0" ACOUSTICAL CEILING TILE (ACT-1: ARMSTRONG DUNE SECOND LOOK OR EQUAL) (ITEMS ON LEGEND ARE NOT TO SCALE) Q 103 OPEN OFFICE ACT-1 14'-0" AFF A B C D E F G H J K L M N P 1 2 3 4 5 6 Q NOT IN SCOPE KEY PLAN SCALE: NTS 6 AREA OF WORK TA3.1 ENLARGED OFFICE RCP PLAN SHEET NUMBER JOB NO : GA1054 PA : MLK DATE : 1/8/2024 REVISIONS AR C H I T E C T CO N T R A C T O R CO N S U L T I N G E N G I N E E R S EL E C T R I C A L : PL U M B I N G : ME C H A N I C A L : 79 3 0 C L A Y T O N R D . S T E 3 0 0 RI C H M O N D , H E I G H T S 6 3 1 1 7 (P ) 3 1 4 - 8 2 2 - 5 1 9 1 WW W . G M A - A R C H I T E C T S . C O M THIS DESIGN AND THESE DRAWINGS ARE THE PROPERTY OF GMA ARCHITECTS, INC. NO PART OF THIS WORK MAY BE REPRODUCED WITHOUT PRIOR WRITTEN PERMISSION FROM GMA ARCHITECTS, INC. VE N T U R E M E C H A N I C A L I N C . 16 4 4 W C R O S B Y R O A D CA R R O L L T O N , T X 7 5 0 0 6 97 2 . 8 7 1 . 1 3 0 0 HU R S T E L E C T R I C C O . 22 9 W . H U R S T B L V D . HU R S T , T X 7 6 0 5 3 81 7 . 2 6 8 . 3 0 0 0 PR O J E C T AR C O / M U R R A Y D E S I G N B U I L D 49 2 5 G R E E N V I L L E A V E # 9 1 5 DA L L A S , T X 7 5 2 0 6 21 4 . 3 7 7 . 6 6 8 1 PR O J E C T S W A N S O N 36 4 2 E U L E S S - G R A P E V I N E R O A D , S U I T E 1 0 0 GR A P E V I N E , T X AO S E N G I N E E R I N G 50 2 0 T E N N Y S O N P A R K W A Y PL A N O , T X 7 5 0 2 4 21 4 . 4 3 2 . 3 0 3 0 FOR RECORD SET 12.18.2024 WALL ANGLE 12 GA. VERTICAL HANGER WIRE CROSS TEE RUNNER AT 24" O.C. FACE OF PARTITION 12 GA. VERTICAL HANGER WIRE AT 48" O.C. MAIN RUNNER AT 48" O.C. 2"MIN. ACOUSTICAL CEILING TILE NOTES: 1. INTERMEDIATE OR HEAVY DUTY MAIN TEE CLASSIFICATIONS 2. ALL WIRE BRACING TO BE ATTACHED TO SUSPENSION MEMBER WITH A MINIMUM OF 3 TURNS. 3. ALL WIRES TO BE SECURED TO THE STRUCTURE ABOVE. 4. 1 IN 6 MAX. PLUMB OF VERTICAL HANGER WIRES. 5. PERIMETER TEE ENDS TIED TOGETHER. 6. LIGHT FIXTURE (ALL TYPES) MECHANICALLY ATTACHED TO GRID PER NEC 410-16 (TWO PER FIXTURE UNLESS INDEPENDENTLY SUPPORTED). 7. PENDANT-HUNG FIXTURES DIRECTLY SUPPORTED FROM STRUCTURE WITH 9 GA. WIRE (OR APPROVED ALTERNATIVE) 8. AIR TERMINALS: 20 LBS OR LESS TO BE POSITIVELY ATTACHED TO GRID. - 20 TO 56 LBS TO BE POSITIVELY ATTACHED TO GRID AND TWO WIRES TO STRUCTURE ABOVE (MAY BE SLACK) - 56 LBS OR OVER TO BE SUPPORTED DIRECTLY TO STRUCTURE ABOVE BY 4 WIRES OR APPROVED ALTERNATIVE. 9. SPRINKLER HEADS AND OTHER PENETRATION CLEARANCE TO BE MIN. 3/8" ON ALL SIDES. 8" MAX. 7/8" MIN. 3/8" MIN. INSTALL IN ACCORDANCE WITH THE 2006 IBC, SECTION 808.1.1.1 AND ASTM C 635 AND ASTM C 636 (NOTE: NOT REQUIRED UNLESS WALL ANGLE LESS THAN 7/8") 3 TA3.2 SCALE: 3" = 1'-0" TYPICAL ACOUSTICAL CEILING GRID DETAIL 2 TA3.2 SCALE: 1 1/2" = 1'-0" GYP. BD. CEILING DETAIL PRE-ENGINEERED GYP BD SUSPENSION SYSTEM - USG ICC ESR- 1222 OR APPROVED EQUAL STEEL CROSS TEE 5/8" TYPE "X" GYP BD MAIN TEE SPLICE 12 GA. HANGER WIRE ATTACH SECURELY TO STRUCTURE ABOVE SECURELY ATTACH GYP BD TO SUSPENSION SYSTEM PER MFR RECOMMENDATIONS MAIN STEEL TEE INSTALL CONTROL JOINTS PER MFR RECOMMENDATIONS CEILING AREAS EXCEEDING 900 SF TO BE SUBDIVIDED W/ CONTROL JOINTS INTO AREAS LESS THAN 900 SF SEE DETAIL 1/TA3.2 USG 093 CONTROL JOINT OR APPROVED EQUAL 5/8" GYP. BD. MAIN TEES 1/2" GYP. BOARD CEILING CJ DETAIL1 TA3.2 SCALE: 1 1/2" = 1'-0" TA3.2 CEILING DETAILS SHEET NUMBER JOB NO : GA1054 PA : MLK DATE : 1/8/2024 REVISIONS AR C H I T E C T CO N T R A C T O R CO N S U L T I N G E N G I N E E R S EL E C T R I C A L : PL U M B I N G : ME C H A N I C A L : 79 3 0 C L A Y T O N R D . S T E 3 0 0 RI C H M O N D , H E I G H T S 6 3 1 1 7 (P ) 3 1 4 - 8 2 2 - 5 1 9 1 WW W . G M A - A R C H I T E C T S . C O M THIS DESIGN AND THESE DRAWINGS ARE THE PROPERTY OF GMA ARCHITECTS, INC. NO PART OF THIS WORK MAY BE REPRODUCED WITHOUT PRIOR WRITTEN PERMISSION FROM GMA ARCHITECTS, INC. VE N T U R E M E C H A N I C A L I N C . 16 4 4 W C R O S B Y R O A D CA R R O L L T O N , T X 7 5 0 0 6 97 2 . 8 7 1 . 1 3 0 0 HU R S T E L E C T R I C C O . 22 9 W . H U R S T B L V D . HU R S T , T X 7 6 0 5 3 81 7 . 2 6 8 . 3 0 0 0 PR O J E C T AR C O / M U R R A Y D E S I G N B U I L D 49 2 5 G R E E N V I L L E A V E # 9 1 5 DA L L A S , T X 7 5 2 0 6 21 4 . 3 7 7 . 6 6 8 1 PR O J E C T S W A N S O N 36 4 2 E U L E S S - G R A P E V I N E R O A D , S U I T E 1 0 0 GR A P E V I N E , T X AO S E N G I N E E R I N G 50 2 0 T E N N Y S O N P A R K W A Y PL A N O , T X 7 5 0 2 4 21 4 . 4 3 2 . 3 0 3 0 FOR RECORD SET 12.18.2024 HEAD FRAME MAT'L SILLJAMB REMARKS DOOR SCHEDULE DETAILSDOOR MAT'L TYPETYPEHEIGHTWIDTHTHICK. SE E S C H E D SEE SCHED INTERIOR FRAME TYPES SCALE: 14"=1'-0" TYPE A DOOR TYPES SCALE: 14"=1'-0" TYPE 1 7' - 0 " 2" 2"SEE SCHED 2" 16 GA WELDED HM (GALV/ PTD) HARDWARE NOTES 1.WHERE WALL STOPS ARE NOT PRACTICAL PROVIDE FLOOR STOPS (IVES 436B OR 438B OR EQUAL) 2.CYLINDRICAL LOCKS SHALL BE GRADE ONE. DEADBOLTS SHALL BE GRADE ONE WITH CYLINDER X LEVER OPERATION LOCK. ALL HARDWARE FINISH TO BE BRUSHED ALUMINUM. 3.ALL DOORS INDICATED AS EXIT DOORS ON LIFE SAFETY PLANS SHALL INCLUDE HARDWARE THAT ALLOWS OPERATION & EGRESS WITHOUT THE USE OF A KEY IN THE DIRECTION OF EGRESS INDICATED BY THE EXIT SIGN ARROWS. ALL SWINGING EGRESS DOORS SHALL RELEASE WITH A FORCE NOT TO EXCEED 5 POUNDS. FIRE DOORS AND DOORS OR GATES REQUIRED TO BE EQUIPPED WITH PANIC HARDWARE, BREAK AWAY FEATURES OR OTHER FACTORS REQUIRING HIGHER OPENING FORCE FOR SAFETY REASONS SHALL ALLOW THE DOOR LATCH TO RELEASE WHEN SUBJECTED TO A 15-POUND (67 N) FORCE MAXIMUM. 4.PROVIDE HARDWARE AS REQUIRED FOR THE NORMAL OPERATION OF EACH DOOR. 5.PROVIDE ACCESSIBLE APPROVED LEVER HANDLE ON ALL SWING (NON-OVERHEAD) DOORS. PROVIDE HAGER HEAVY DUTY SERIES (OR EQUAL) IN WAREHOUSE AREAS AND SCHLAGE MEDIUM DUTY SERIES (OR EQUAL) IN OFFICE AREAS. 6.ALL HARDWARE SHALL COMPLY WITH THE ACCESSIBILITY CODE LISTED ON THE COVER SHEET. 7.CLOSERS SHALL BE LCN OR APPROVED EQUAL. 8.LOCKSET FUNCTION TO BE DETERMINED BY THE GENERAL CONTRACTOR AND APPROVED BY THE OWNER. 9. ALL DOORS TO UTILIZE IC CORES AND BE KEYED ALIKE. 10.BALL BEARING HINGES SHALL HAVE NON-REMOVABLE PINS. 11.EXTERIOR DOORS SHALL BE PROVIDED WITH ACCESSIBLE ANODIZED ALUMINUM THRESHOLDS WITH A MAXIMUM HEIGHT OF 1/2" AND BEVELED EDGE SLOPES NO GREATER THAN 1:12 12.RATED DOORS AND FRAMES SHALL BEAR AN APPROVED LABEL INDICATING (1) THE RATING FOLLOWED BY THE LETTER "S", (2) THE MANUFACTURER AND (3) THE NAME OF THE 3RD PARTY INSPECTION AGENCY. 18 GA INSUL. HM DOOR (GALV/ PTD) INTERIOR HARDWARE SCHEDULE FIRE RATING HDW GROUP ROOM # DOOR # GROUP #1 - UNISEX RR'S ·1-1/2 PR BUTTS ·PRIVACY LOCKSET W/ OCCUPANCY INDICATOR ·WALL STOP ·CLOSER ·SILENCER ·KICK PLATE (WAREHOUSE SIDE) GROUP #2 - CLASSROOM LOCKSET ·1-1/2 PR BUTTS ·CLASSROOM LOCKSET ·WALL STOP ·CLOSER ·SILENCER ·KICK PLATE (WAREHOUSE SIDE) GROUP #3 - CLASSROOM SECURITY LOCKSET ·1-1/2 PR BUTTS ·CLASSROOM SECURITY LOCKSET ·WALL STOP ·CLOSER ·SILENCER 103A 104 105 106 107A 108 109 110 ------1 HM ---A HM 103 ---HM 3'-0"7'-0"---A3 3 ------HM 3'-0"7'-0"---A HM1 23/A4.1 3/A4.1 ------HM 3'-0"7'-0"---A HM1 1 107 ---3'-0"7'-0"---3 3 ------3'-0"7'-0"---1 INTERIOR TYPE B 7' - 0 " 2" 2"SEE SCHED 2" 16 GA ALUM (GALV/ PTD) SE E S C H E D SEE SCHED INTERIOR TYPE 2 SOLID CORE WOOD DOOR 103B 107B 103 ---HM 3'-0"7'-0"---3 3 107 ---2 B ALUM 2 ------3'-0"7'-0"---1 ------3'-0"7'-0"---2 3'-0"7'-0" 2 2 2 WD HM WD WD WD 3'-0"7'-0"--- A A B B B ALUM ALUM ALUM 1 --- --- 2/A4.1 1/A4.1 --- --- 2/A4.1 1/A4.1 --- 2/A4.1 1/A4.1 --- 2/A4.1 1/A4.1 --- --- --- --- 3/A4.1 3/A4.1 3/A4.1 3/A4.1 INTERIOR TYPE 3 18 GA INSUL. HM DOOR (GALV/PTD) SE E S C H E D SEE SCHED 3' - 6 " 2' - 3 " 6"6 1/2" T HM 3/A4.1 3/A4.1 HM 3/A4.1 3/A4.1 HM 3/A4.1 3/A4.1 NO KICK PLATES NO KICK PLATES NO KICK PLATES NO KICK PLATES DOOR AS SCHEDULED 1 3 / 4 " 6" 4 7 / 8 " DOOR JAMB 3 5/8" METAL STUD DOOR JAMB CASING DOOR HEAD STOP 2" 1 1/4" 5/8" GYPSUM WALLBOARD 1 TA4.1 SCALE: 3" = 1'-0" ALUM DOOR JAMB DETAIL DOOR AS SCHEDULED 1 3/4" 6" 4 7/8" DOOR HEAD 3 5/8" METAL STUD DOOR HEAD CASING DOOR HEAD STOP ALUMINUM FRAME 2" 1 1 / 4 " 5/8" GYPSUM WALLBOARD 2 TA4.1 SCALE: 3" = 1'-0" ALUM DOOR HEAD DETAIL SE E D O O R SC H E D U L E 2" 1/2" DO O R O P E N I N G HM MAN DR HEAD/JAMB AT GYP. GYPSUM BOARD ON METAL STUDS - REFER PARTITION TYPES DOUBLE STUD @ JAMB RUNNER CHANNEL @ HEAD REFER TO WALL TYPE FOR STUD SIZE & GAUGE CONT. SEALANT, BOTH SIDES HOLLOW METAL FRAME STANDARD Z ANCHORS 3 PER JAMB MIN. REFER TO WALL TYPE TO DETERMINE REQUIRED FRAME WIDTH WOOD OR HOLLOW METAL DOOR - SEE DOOR SCHEDULE 3 TA4.1 SCALE : 1 1/2"=1'-0"TA4.1 DOOR SCHEDULE SHEET NUMBER JOB NO : GA1054 PA : MLK DATE : 1/8/2024 REVISIONS AR C H I T E C T CO N T R A C T O R CO N S U L T I N G E N G I N E E R S EL E C T R I C A L : PL U M B I N G : ME C H A N I C A L : 79 3 0 C L A Y T O N R D . S T E 3 0 0 RI C H M O N D , H E I G H T S 6 3 1 1 7 (P ) 3 1 4 - 8 2 2 - 5 1 9 1 WW W . G M A - A R C H I T E C T S . C O M THIS DESIGN AND THESE DRAWINGS ARE THE PROPERTY OF GMA ARCHITECTS, INC. NO PART OF THIS WORK MAY BE REPRODUCED WITHOUT PRIOR WRITTEN PERMISSION FROM GMA ARCHITECTS, INC. VE N T U R E M E C H A N I C A L I N C . 16 4 4 W C R O S B Y R O A D CA R R O L L T O N , T X 7 5 0 0 6 97 2 . 8 7 1 . 1 3 0 0 HU R S T E L E C T R I C C O . 22 9 W . H U R S T B L V D . HU R S T , T X 7 6 0 5 3 81 7 . 2 6 8 . 3 0 0 0 PR O J E C T AR C O / M U R R A Y D E S I G N B U I L D 49 2 5 G R E E N V I L L E A V E # 9 1 5 DA L L A S , T X 7 5 2 0 6 21 4 . 3 7 7 . 6 6 8 1 PR O J E C T S W A N S O N 36 4 2 E U L E S S - G R A P E V I N E R O A D , S U I T E 1 0 0 GR A P E V I N E , T X AO S E N G I N E E R I N G 50 2 0 T E N N Y S O N P A R K W A Y PL A N O , T X 7 5 0 2 4 21 4 . 4 3 2 . 3 0 3 0 FOR RECORD SET 12.18.2024 CLIP ANGLE WITH SCREW OR WELD ATTACHMENT COLD ROLLED CHANNEL 6 TA4.2 SCALE: 1 1/2" = 1'-0" LATERAL BRACING STUDS PER PARTITION TYPE NOTE: ALTERNATIVE LATERAL BRACING METHODS SHALL BE CONSIDERED. FRAMING SUBCONTRACTOR TO NOTIFY GENERAL CONTRACTOR IF ALTERNATE LATERAL BRACING METHOD IS BEING PROPOSED STUD SIZE 362S125-18 16"4'-0" 362S125-27 16" 362S137-33 16" 362S200-33 16" 362S200-68 16" SIZE SPACING SPAN CEILING TILES (BRACING SPACING)SPACING SPAN MAXIMUM SPAN MAXIMUM SPAN 362S125-18 (25 GA.)16"11'-0"24"9'-0" 362S125-33 (20 GA.)16"13'-6"24"12'-6" 600S125-33 (20 GA.)16"20'-6"24"18'-0" CEILING JOISTS (NON-LOAD BEARING) INTERIOR PARTITION (NON-LOAD BEARING) 1-STUD & 1-TRACK 2-STUD & 1-TRACK 3-STUD & 1-TRACK 4-STUD & 1-TRACK 5-STUD & 1-TRACK (1) xxxS162-43 w/ (2) 33 MIL MIN TRACKS (1) xxxS200-33 w/ (2) 33 MIL MIN TRACKS AT INT. (2) 362S162-33 w/ (2) 33 MIL MIN TRACKS AT DEMISING (2) 600S162-33 w/ (2) 1000T125-43, 800T125-33, 600T125-33 OR 362T125-43 (2) 800S162-33 w/ (2) 1000T125-43, 800T125-43, 600T125-54, OR 362T125-54 4'-0" 8'-0" 10'-0" 12'-0" 6'-0" SEE SECTION SEE SECTION (4) #8 SCREWS EA END TOTAL (4) #8 SCREWS EA END TOTAL (4) #8 SCREWS EA END TOTAL KING STUDS, U.N.O.SPAN HEADER SIZE BOX BEAM HEADERS GY P . B O A R D C E I L I N G DE T A I L X A4 . X 4'-0" 3'-6" 3'-6" STUD SPACING BRIDGING SPACING MAX. PARTITION HEIGHT 11'-4" 15'-3" 18'-3" 22'-5" 26'-6" 362S200-68 12"28'-6" 4'-0" 6'-0" 6'-0" 6'-0" 6'-0" 600S137-33 16"6'-0" 600S200-33 16" 600S250-54 16" 600S250-97 16" 600S250-97 12" 25'-2" 30'-0" 35'-0" 39'-11" 6'-0" 6'-0" 6'-0" 6'-0"42'-11" STUD SIZE 800S200-33 16"6'-0" 800S250-43 16" 800S250-68 16" 800S250-97 16" 800S250-97 12" STUD SPACING BRIDGING SPACING MAX. PARTITION HEIGHT 35'-7" 39'-2" 43'-8" 47'-4" 50'-10" 1000S162-43 16"41'-7" 6'-0" 6'-0" 6'-0" 6'-0" 6'-0" 1000S250-43 16"6'-0" 1000S250-54 16" 1000S250-97 16" 44'-9" 47'-3" 54'-1" 6'-0" 6'-0" HEADER SCHEDULE (NON-LOAD BEARING) 6-STUD & 1-TRACK 14'-0" 16'-0" (6) #8 SCREWS EA END TOTAL (8) #8 SCREWS EA END TOTAL CONNECTION (2) 1000S162-43 w/ (3) 1000T125-43, 800T125-43, 600T125-54 OR 362T125-68 (2) 800S162-43 w/ (3) 1000T125-43, 800T125-43, 600T125-43 OR 362T125-54 (2) 600S162-33 w/ (2) 1000T125-43, 800T125-33, 600T125-43 OR 362T125-54 (4) #8 SCREWS EA END TOTAL 6-STUD & 1-TRACK METAL STUD WALL SIZE & SPACING SEE SECTIONS AND STUD SCHEDULE SEE HEADER SCHED. ATTACHED TRACK TO STUD WITH #8 (#7 @ 18 MIL. STUDS) SCREW AT EACH FLANGE 33 MIL. TYP. UP TO 10'-0" OPENING 43 MIL. UP TO 12'-0" OPN'G.54 MIL. UP TO 16'-0" OPN'G. OPENING SEE HEADER SCHED. #8 SCREWS SEE SCHED. METAL STUD WALL SIZE & SPACING SEE SECTIONS AND STUD SCHEDULETRACK SEE HEADER SCHED. ATTACH TRACK TO STUD AT EACH FLANGE W/ #8 SCREWS TOP TRACK ATTACH BACK TO BACK STUDS W/ #8 SCREWS @ 12" O.C. ATTACH TRACK TO STUD AT EACH FLANGE W/ #8 SCREWS CONC. SLAB CONT. TRACK W/ .180" POWER DRIVEN SHOT PINS AT 16" O.C. U.N.O. AT SECTIONS (ESR-1799) OR APPROVED EQUAL CONT. TRACK W/ .180" POWER DRIVEN SHOT PINS AT 16" O.C. U.N.O. AT SECTIONS (ESR-1799) OR APPROVED EQUAL (1) POWER DRIVEN SHOT PIN FOR EACH KING STUD, TYP. CONC. SLAB CLOSURE STUD REQ'D FOR OPENING JAMB #8 SCREWS @ 12" O.C. BUILT-UP HEADER SEE SCHEDULE OPENING #8 SCREWS @ 12" O.C. 1.UNLESS NOTED OTHERWISE ON THE PLANS, USE THE FOLLOWING COLD-FORMED STEEL FRAMING FOR INTERIOR NON-LOAD BEARING PARTITIONS. 2.ALL FRAMING SHALL CONFORM TO THE BUILDING CODE; REFER TO THE SHEETS AT THE BEGINNING OF THE SET FOR BUILDING CODE USED. IT IS THE SUBCONTRACTOR'S RESPONSIBILITY TO FOLLOW THE CURRENT CODES ADOPTED BY THE AUTHORITY HAVING JURISDICTION. 3.ALL FRAMING HAS BEEN DESIGNED PER THE AISI S100 AND AISI S211 FOR A LATERAL LOAD OF 5PSF WITH DEFLECTION LIMITS OF L/120 AND 2" MAXIMUM. 4.ALL MEMBERS SHALL BE ASTM A1003, 50KSI FOR MEMBERS 54MIL (16GAGE) AND THICKER, 33KSI FOR MEMBERS 43MIL (18GAGE) AND THINNER, ZINC COATED MEETING ASTM A525, G-60 OR EQUIVALENT. 5.ALL KING STUDS SHALL BE FULL HEIGHT AND SHALL MATCH THE TYPICAL STUD SIZE. 6.ALL TRACKS SHALL MATCH THE WALL STUD DEPTH, AND SHALL BE A MINIMUM OF 33MIL (20GAGE) THICK. STUDS SHALL BEAR 1" MINIMUM ON TOP AND BOTTOM TRACK FLANGES. DEFLECTION TRACKS SHALL BE SELECTED TO MEET THE STANDARD DEFLECTION LIMITS FOR THE FRAMING ABOVE: SPAN/240 FOR ROOF MEMBERS, AND SPAN/360 FOR FLOOR MEMBERS. EXAMPLE: a.FOR A DEFLECTION TRACK LOCATED UNDER OR ADJACENT TO A 60'-0" SPAN ROOF JOIST, THE DEFLECTION TRACK SHALL ALLOW FOR THE FOLLOWING: GAP = (60 FT X 12 INCHES/FT)/240 = 3 INCHES 7.WALLBOARD CONTROL JOINTS SHALL BE SPACED AT A MAXIMUM OF 24'-0" HORIZONTAL AND 25'-0" VERTICAL. 1.ALL FRAMING SHALL CONFORM TO THE BUILDING CODE AND AISI S100. 2.WHERE CEILING SUPPORTED TOILET PARTITIONS OCCUR, USE 600S125-43 @ 16" O.C. UP TO 16'-0" MAXIMUM SPAN. 3.362S125-43 CEILING TIES (SEE SCHEDULE) WITH 1 - #8 SCREW AT EACH JOIST. 4.DESIGN LOAD: DEAD LOAD = 5 PSF, DEFLECTION LIMIT L/360 600 S 162 54 DE P T H LI P FL A N G E WI D T H C-STUD/ JOIST TRACK CHANNEL FURRING CHANNELS-SECTIONS T-SECTIONS U-SECTIONS F-SECTIONS STYLE: (EXAMPLE: STUD OR JOIST SECTION = S) THE FOUR ALPHA CHARATCERS UTLIZED BY THE DESIGNATOR SYSTEM ARE: S = STUD OF JOIST SECTIONS T = TRACK SECTIONS U = CHANNEL SECTIONS F = FURRING CHANNEL SECTIONS MATERIAL THICKNESS: (EXAMPLE: 0.054 IN. = 54 MILS; 1 MIL = 1/1000 IN.) DESIGNATOR SYSTEM ARE: MATERIAL THICKNESS IS THE MINIMUM BASE METAL THICKNESS IN MILS. MINIMUM BASE METAL THICKNESS REPRESENTS 95% OF THE DESIGN THICKNESS. EXAMPLE: - MEMBER DEPTH: (EXAMPLE: 6" = 600 X 1/100 INCHES) ALL MEMBER DEPTHS ARE TAKEN IN 1/100 INCHES FOR ALL "T" SECTIONS MEMBER DEPTH IS THE INSIDE TO INSIDE DIMENSION. FLANGE WIDTH: (EXAMPLE: 1 5/8" = 1.625"=162 X 1/100 INCHES) ALL FLANGE WIDTHS ARE TAKEN IN 1/100 INCHES 45° 6" METAL STUD DIAGONAL BRACE WHERE REQUIRED. SEE STRUCTURAL DRAWINGS. 12 GA. HANGER WIRE METAL STUD WALL WITH 5/8" THK. GYPSUM BOARD AT BOTH SIDES SUSPENDED ACOUSTIC CEILING TILE 2 TA4.2 SCALE: 1 1/2" = 1'-0" PARTITIONS THAT BREAK THE GRID BRACING DETAIL FOR FLOOR / ROOF ASSEMBLY AS APPLICABLE HOLD GYPSUM BOARD PANELS TIGHT TO BOTTOM OF DECK FASTENERS AT 3" O.C. MAX BlazeFrame RipTrack DEFLECTION TRACK RipTRAK Clip (RTC) ON EACH SIDE OUTER / OVERLAPPING GYPSUM BOARD STRIPS TEAR AWAY BEAD (EACH SIDE) 5/8" GYP BD - SEE PARTITION TYPE VARIES REFER TO PARTITION TYPE 5 1/ 2 " NO M I N A L JO I N T 2" 2" 3" B. O . TR A C K DEFLECTION TRACK AT JOIST - GIRDER3 TA4.2 SCALE: 1 1/2" = 1'-0" METAL DECK - SEE STRUCTURAL STOP DRYWALL 1/2" FROM DECK & CAULK 5/8" DRYWALL ON 1-5/8" METAL STUDS @ 16" C/C - USE TYPE "X" GYP. BD. AT RATED WALLS STEEL JOIST - SEE STRUCT. DEFLECTION TRACK - ANCHOR TO JOIST PER PARTITION TYPE COMPRESSIBLE FILLER TRACK RUNNER SET INSIDE OF DEFLECTION TRACK METAL STUD - SEE PARTITION TYPES FILL GAPS W/ MINERAL WOOL AT RATED PARTITIONS NOTES: 1.USE FIRE RATED CAULK AS REQUIRED PER U.L. #, FOR RATED PARTITIONS 2.WHEN PERPENDICULAR TO JOIST, ALIGN WITH BOTTOM CHORD OF JOIST 3.WHEN WALLS DO NOT HIT JOIST, PROVIDE DEFLECTION TRACK AT UNDERSIDE OF DECK * TEAR AWAY BEAD (EACH SIDE) OVERLAP TOP DRYWALL JOIST ENCASEMENT OVER FACE OF DEMISING WALL. DO NOT ATTACH TO DEFLECTION TRACK VARIES REFER TO PARTITION TYPE FLOOR / ROOF ASSEMBLY AS APPLICABLE * : 1.5x SIZE OF DEFLECTION TRACK LEG LENGTH. SEE STRUCTURAL. COORDINATE DEFLECTION TRACK WITH ANTICIPATED MOVEMENT OF STRUCTURE 1/4" BEAD OF AC. SEALANT AT PARTITION TYPES W/ SOUND ATTENUATING BLANKET. FLOOR ANCHORAGE OF PARTITION1 BASE VARIES - REF. SCHEDULE MTL. RUNNER TRACK W/ POWER DRIVEN FASTENERS @ 24" 0.C. NO. OF LAYERS OF GYP. BOARD AS INDICATED BY PART. TYPE. ENCLOSE TOP, BOTTOM, BACK AND SIDES OF ALL MECHANICAL AND ELECTRICAL DEVICES W/ AC. SEALANT AT PARTITION TYPES W/ SOUND ATTENUATING BLANKETS. "V" GROOVE DRYWALL CONTROL JOINT 25'-0" O.C. MAX. BOTH SIDES 5/8" 1/2" MAX. 2 CONTROL JOINT WHI-495-PSV-0824 1 TA4.2 SCALE: 1 1/2" = 1'-0" 4 TA4.2 SCALE: 1 1/2" = 1'-0" DEFLECTION TRACK DETAIL AT METAL DECK PARTITION DETAILS CEILING GRID STOPS AT PARTITION SEISMIC BRACING SYSTEM FOR PARTITIONS IS TO BE INDEPENDENT OF BRACING SYSTEM FOR CEILINGS SCHEDULED PARTITION SCHEDULED CEILING SEE REFLECTED CEILING PLAN METAL STUD BRACING SECURELY ATTACH TO STRUCTURE ABOVE AND TOP TRACK BELOW 5 TA4.2 SCALE: 3" = 1'-0" THAT BREAK THE GRID BRACING DETAIL FOR PARTITIONS TA4.2 PARTITION DETAILS SHEET NUMBER JOB NO : GA1054 PA : MLK DATE : 1/8/2024 REVISIONS AR C H I T E C T CO N T R A C T O R CO N S U L T I N G E N G I N E E R S EL E C T R I C A L : PL U M B I N G : ME C H A N I C A L : 79 3 0 C L A Y T O N R D . S T E 3 0 0 RI C H M O N D , H E I G H T S 6 3 1 1 7 (P ) 3 1 4 - 8 2 2 - 5 1 9 1 WW W . G M A - A R C H I T E C T S . C O M THIS DESIGN AND THESE DRAWINGS ARE THE PROPERTY OF GMA ARCHITECTS, INC. NO PART OF THIS WORK MAY BE REPRODUCED WITHOUT PRIOR WRITTEN PERMISSION FROM GMA ARCHITECTS, INC. VE N T U R E M E C H A N I C A L I N C . 16 4 4 W C R O S B Y R O A D CA R R O L L T O N , T X 7 5 0 0 6 97 2 . 8 7 1 . 1 3 0 0 HU R S T E L E C T R I C C O . 22 9 W . H U R S T B L V D . HU R S T , T X 7 6 0 5 3 81 7 . 2 6 8 . 3 0 0 0 PR O J E C T AR C O / M U R R A Y D E S I G N B U I L D 49 2 5 G R E E N V I L L E A V E # 9 1 5 DA L L A S , T X 7 5 2 0 6 21 4 . 3 7 7 . 6 6 8 1 PR O J E C T S W A N S O N 36 4 2 E U L E S S - G R A P E V I N E R O A D , S U I T E 1 0 0 GR A P E V I N E , T X AO S E N G I N E E R I N G 50 2 0 T E N N Y S O N P A R K W A Y PL A N O , T X 7 5 0 2 4 21 4 . 4 3 2 . 3 0 3 0 FOR RECORD SET 12.18.2024 1.SEAL ALL PENETRATIONS. 2.REFER TO SHEET TA4.2 FOR SIZING OF ALL METAL STUDS BASED ON HEIGHT. 3.ALL INTERIOR WALL AND CEILING FINISH MATERIALS SHALL BE CLASSIFIED IN ACCORDANCE WITH ASTM E84 OR UL 723, AND SHALL CARRY CLASS C FLAME SPREAD AND SMOKE DEVELOPED INDEXES: FLAME SPREAD INDEX: 76-200 SMOKE DEVELOPED INDEX: 0-450 4.MATERIALS EXPOSED WITHIN DUCTS OR PLENUMS SHALL BE NONCOMBUSTIBLE OR SHALL HAVE A FLAME SPREAD INDEX NOT TO EXCEED 25 AND A SMOKE DEVELOPED INDEX NOT TO EXCEED 50, WHERE TESTED AS A COMPOSITE PRODUCT IN ACCORDANCE WITH ASTM E84 OR UL 723. PARTITION NOTES 5/8"3 5/8"5/8" 4 7/8" 1/ 2 " 3 5/8" METAL STUD-INSULATEDP3 6" BRACE AS REQUIRED RE: TO DETAILS 2/TA4.1 AND 5/TA4.1 CONTINUOUS 20 GA. RUNNER TRACK CEILING AS SCHEDULED 3 5/8" METAL STUDS. SEE CHART FOR GAUGING & SPACING BASED ON HEIGHT. PROVIDE FULL CAVITY SOUND ATTENUATION BATTS BASE AS SCHEDULED HOLD BTM. OF GYP. BD. 1/2" OFF FLOOR FLOOR DECK SOUND ATTENUATION BATTS 4'-0" HORIZONTALLY EACH SIDE OF PARTITION P1 5/8"3/4"3 5/8" 5" (U.N.O.) FLOOR 1/ 2 " 3-5/8" METAL STUD FURRED WALL - INSULATED DECK 5/8" TYPE X GYPSUM BOARD 3-5/8" METAL STUDS. SEE CHART FOR GAUGING AND SPACING BASED ON HEIGHT FULL CAVITY THERMAL BATTS ; (R-13 MIN - CONFIRM W/ MECHANICAL ENGINEER) BASE AS SCHEDULED. SEE FINISH SHEETS HOLD BTM. OF GYP. BD. 1/2" OFF FLOOR ACOUSTICAL SEALANT SCALE: 1 1/2" = 1'-0" SCHEDULED CEILING (SEE REFLECTED CEILING PLAN) EX. CONC. TILT WALL / CMU WALL. SEE FLOOR PLAN SEE STRUCT. 6" FOIL FACED STICK-PIN INSULATION TO DECK (R-13 MIN - CONFIRM W/ MECHANICAL ENGINEER) 5/8"5/8"8" 9 1/4" 1/ 2 " P5 FULL HT. 8" METAL STUD-INSULATED DEFLECTION TRACK - SEE 3/TA4.1 AND 4/TA4.1 ALL PENETRATIONS AND JOINTS (PARTITION TO DECK AND PARTITION TO FLOOR) TO BE PROPERLY SEALED/CAULKED 5/8" TYPE "X" GYPSUM BOARD EACH SIDE. RUN TO DECK ON WAREHOUSE SIDE ONLY. 8" METAL STUDS. SEE CHART FOR GAUGING & SPACING BASED ON HEIGHT R-13 THERMAL BATTS WITH VAPOR BARRIER BASE AS SCHEDULED HOLD BTM. OF GYP. BD. 1/2" OFF FLOOR SCALE: 1 1/2" = 1'-0" FLOOR SCHEDULED CEILING - WHERE OCCURS (SEE REFLECTED CEILING PLAN) 6" SOUND BATTING ACOUSTICAL SEALANT UNDER DECK INSULATION WAREHOUSE SIDE PLUMBING WALL SEE PLAN 5/8"5/8" P4 RE : T O R C P FO R C E I L I N G H E I G H T S SCHEDULED CEILING DRYWALL GUSSETS TOP, BOTTOM & MIDDLE 3 5/8" METAL STUDS. SEE CHART FOR GAUGING & SPACING BASED ON HEIGHT R-19 BATT INSUL. MOISTURE RESISTANT 5/8" GYPSUM BOARD ON BOTH SIDES BASE AS SCHEDULED FLOOR 6" 5/8" GYPSUM BOARD BRACE AS REQUIRED RE: SHEET TA4.1 SCALE: 1 1/2" = 1'-0" BATT INSULATION TO DECK. STRAPPING TO HOLD IN PLACE. (R-13 MIN - CONFIRM W/ MECHANICAL ENGINEER) 5/8" TYPE "X" GYPSUM BOARD EACH SIDE. RUN TO DECK ON WAREHOUSE SIDE ONLY. A4.3 PARTITION TYPES SHEET NUMBER JOB NO : GA1054 PA : MLK DATE : 1/8/2024 REVISIONS AR C H I T E C T CO N T R A C T O R CO N S U L T I N G E N G I N E E R S EL E C T R I C A L : PL U M B I N G : ME C H A N I C A L : 79 3 0 C L A Y T O N R D . S T E 3 0 0 RI C H M O N D , H E I G H T S 6 3 1 1 7 (P ) 3 1 4 - 8 2 2 - 5 1 9 1 WW W . G M A - A R C H I T E C T S . C O M THIS DESIGN AND THESE DRAWINGS ARE THE PROPERTY OF GMA ARCHITECTS, INC. NO PART OF THIS WORK MAY BE REPRODUCED WITHOUT PRIOR WRITTEN PERMISSION FROM GMA ARCHITECTS, INC. VE N T U R E M E C H A N I C A L I N C . 16 4 4 W C R O S B Y R O A D CA R R O L L T O N , T X 7 5 0 0 6 97 2 . 8 7 1 . 1 3 0 0 HU R S T E L E C T R I C C O . 22 9 W . H U R S T B L V D . HU R S T , T X 7 6 0 5 3 81 7 . 2 6 8 . 3 0 0 0 PR O J E C T AR C O / M U R R A Y D E S I G N B U I L D 49 2 5 G R E E N V I L L E A V E # 9 1 5 DA L L A S , T X 7 5 2 0 6 21 4 . 3 7 7 . 6 6 8 1 PR O J E C T S W A N S O N 36 4 2 E U L E S S - G R A P E V I N E R O A D , S U I T E 1 0 0 GR A P E V I N E , T X AO S E N G I N E E R I N G 50 2 0 T E N N Y S O N P A R K W A Y PL A N O , T X 7 5 0 2 4 21 4 . 4 3 2 . 3 0 3 0 FOR RECORD SET 12.18.2024 QP 56 -SEE SHELL DRAWING FOR ADDITIONAL ELEVATIONS EXTERIOR OFFICE - NORTH ELEVATION1 TA5.1 SCALE: 1" = 20'-0" EXTERIOR OFFICE - EAST ELEVATION2 TA5.1 SCALE: 1" = 20'-0" -SEE SHELL DRAWING FOR ADDITIONAL ELEVATIONS TA5.1 EXTERIOR OFFICE ELEVATIONS SHEET NUMBER JOB NO : GA1054 PA : MLK DATE : 1/8/2024 REVISIONS AR C H I T E C T CO N T R A C T O R CO N S U L T I N G E N G I N E E R S EL E C T R I C A L : PL U M B I N G : ME C H A N I C A L : 79 3 0 C L A Y T O N R D . S T E 3 0 0 RI C H M O N D , H E I G H T S 6 3 1 1 7 (P ) 3 1 4 - 8 2 2 - 5 1 9 1 WW W . G M A - A R C H I T E C T S . C O M THIS DESIGN AND THESE DRAWINGS ARE THE PROPERTY OF GMA ARCHITECTS, INC. NO PART OF THIS WORK MAY BE REPRODUCED WITHOUT PRIOR WRITTEN PERMISSION FROM GMA ARCHITECTS, INC. VE N T U R E M E C H A N I C A L I N C . 16 4 4 W C R O S B Y R O A D CA R R O L L T O N , T X 7 5 0 0 6 97 2 . 8 7 1 . 1 3 0 0 HU R S T E L E C T R I C C O . 22 9 W . H U R S T B L V D . HU R S T , T X 7 6 0 5 3 81 7 . 2 6 8 . 3 0 0 0 PR O J E C T AR C O / M U R R A Y D E S I G N B U I L D 49 2 5 G R E E N V I L L E A V E # 9 1 5 DA L L A S , T X 7 5 2 0 6 21 4 . 3 7 7 . 6 6 8 1 PR O J E C T S W A N S O N 36 4 2 E U L E S S - G R A P E V I N E R O A D , S U I T E 1 0 0 GR A P E V I N E , T X AO S E N G I N E E R I N G 50 2 0 T E N N Y S O N P A R K W A Y PL A N O , T X 7 5 0 2 4 21 4 . 4 3 2 . 3 0 3 0 FOR RECORD SET 12.18.2024 SE E C O R E A N D S H E L L D R A W I N G S FINISH FLOOR EL. = 100'-0" B WALL SECTION1 TA6.1 SCALE: 3/8" = 1'-0" WALL SECTION2 TA6.1 SCALE: 3/8" = 1'-0" 14 ' - 0 " R . O . 2' - 0 " 9' - 6 " R . O . VA R I E S - S E E C O R E A N D S H E L L D R A W I N G S SPANDREL GLASS. SEE WINDOW TYPE B FINISH FLOOR EL. = 100'-0" 14 ' - 0 " R . O . 2' - 0 " T/ PANEL B/ WD BLOCKING 3' - 0 3 / 8 " R . O . SPANDREL GLASS. SEE WINDOW TYPE D SE E C O R E A N D S H E L L D R A W I N G S T/ PANEL B/ WD BLOCKING VA R I E S - C O R E A N D S H E L L D R A W I N G S B D 2'-6" 2' - 0 " CL CL WINDOW PREFIN. ALUM FRAME 2"2" 6'-0"5'-8" 18'-0" 2"2" 5'-8" 2" 2' - 8 " 2" 3' - 6 " 2" 2' - 8 " 2" 9' - 6 " 1" INSULATED GLASS NOTE:S = SPANDREL GLASS S S S S S S S S S 16 ' A F F 2"2" 6'-0"3'-8" 14'-6" 2"2" 4'-2" 2" 2' - 8 " 2" 3' - 0 " 16 ' A F F DWINDOW PREFIN. ALUM FRAME S SS WINDOW TYPE LEGEND TA6.1 WALL SECTIONS SHEET NUMBER JOB NO : GA1054 PA : MLK DATE : 1/8/2024 REVISIONS AR C H I T E C T CO N T R A C T O R CO N S U L T I N G E N G I N E E R S EL E C T R I C A L : PL U M B I N G : ME C H A N I C A L : 79 3 0 C L A Y T O N R D . S T E 3 0 0 RI C H M O N D , H E I G H T S 6 3 1 1 7 (P ) 3 1 4 - 8 2 2 - 5 1 9 1 WW W . G M A - A R C H I T E C T S . C O M THIS DESIGN AND THESE DRAWINGS ARE THE PROPERTY OF GMA ARCHITECTS, INC. NO PART OF THIS WORK MAY BE REPRODUCED WITHOUT PRIOR WRITTEN PERMISSION FROM GMA ARCHITECTS, INC. VE N T U R E M E C H A N I C A L I N C . 16 4 4 W C R O S B Y R O A D CA R R O L L T O N , T X 7 5 0 0 6 97 2 . 8 7 1 . 1 3 0 0 HU R S T E L E C T R I C C O . 22 9 W . H U R S T B L V D . HU R S T , T X 7 6 0 5 3 81 7 . 2 6 8 . 3 0 0 0 PR O J E C T AR C O / M U R R A Y D E S I G N B U I L D 49 2 5 G R E E N V I L L E A V E # 9 1 5 DA L L A S , T X 7 5 2 0 6 21 4 . 3 7 7 . 6 6 8 1 PR O J E C T S W A N S O N 36 4 2 E U L E S S - G R A P E V I N E R O A D , S U I T E 1 0 0 GR A P E V I N E , T X AO S E N G I N E E R I N G 50 2 0 T E N N Y S O N P A R K W A Y PL A N O , T X 7 5 0 2 4 21 4 . 4 3 2 . 3 0 3 0 FOR RECORD SET 12.18.2024 1. 7. 9. 8. 3. 6. 5. 2. 4. GENERAL NOTES 10. PA I N T PAINT - GYPSUM BOARD CEILING GYP. COLOR: CEILING BRIGHT WHITE SW7007 MFG PAINT: SHERWIN WILLIAMS FINISH: PRO-MAR 400 FLAT WALL TREATMENT (OFFICE AREA)BASE FINISH SPECIFICATIONS FLOORING MILLWORK PL A S T I C L A M I N A T E SU R F A C E S CO U N T E R T O P WA L L T I L E FR P FIBER REINFORCED PANEL-JANITOR MFG: KEMLITE GLASBORD COLOR: 85 WHITE REFER TO ELEVATIONS TO VERIFY FINISHES AND FOR ADDITIONAL FINISH INFORMATION. ALL INTERIOR HOLLOW METAL DOOR FRAMES SHALL BE BE PAINTED (ENAMEL FINISH) P-3. INSTALL ALL MATERIALS ACCORDING TO MANUFACTURER'S INSTRUCTIONS. DO NOT PAINT ANY EXTERIOR PREFINISHED WINDOW/STOREFRONT FRAMES. ALL BULKHEADS/CASED OPENINGS SHALL BE PAINTED TO MATCH ADJACENT SURFACE, UNLESS NOTED OTHERWISE. PROVIDE AND CONTINUE SCHEDULED FLOORING FROM WALL TO WALL INCLUDING UNDER MILLWORK UNLESS OTHERWISE NOTED. INSTALL THE FOLLOWING TRANSITION STRIPS BETWEEN FLOORING CHANGES; CPT TO CONCRETE - JOHNSONITE EG-20-J IN COLOR 20 CHARCOAL DO NOT PUT VINYL BASE AT CONCRETE OR IMP WALLS. ALL WOOD TO BE STAINED TO MATCH ARCHITECTS SAMPLE IF NOT ALREADY PRE-FINISHED. NO FINISH/MATERIAL SUBSTITUTIONS WILL BE ACCEPTED UNLESS REVIEWED AND APPROVED BY ARCHITECT. PAINT ALL HVAC LOUVERS/GRILLS IN A PARTITION TO MATCH THAT PARTITION. 11. B-1 4" COVE BASE MFG: TARKETT COLOR: 20 CHARCOAL P-1 PAINT - FIELD MFG: SHERWIN WILLIAMS COLOR: EXTRA WHITE SW7006 P-2 PAINT - ACCENT FINISH: EGGSHELL WT-1 FRP-1 LAMINATE CABINETSPL-1 SS-1 MFG: FORMICA STYLE: GRAPHITE 837-58 WOOD WD-1 CO N C R E T E SOLID SURFACE MFG: FORMICA COLOR: BLEACHED CONCRETE 601-S1 MFG: VT INDUSTRIES COLOR: RIVERSTONE RI18 STYLE: PLAIN SLICED SELECT WHITE BIRCH 12. FRP-1 SHALL BE INSTALLED AT WAREHOUSE RESTROOMS & JANITOR CLOSETS 4'-0" HIGH A.F.F. ON ALL WET WALLS. SEE FINISH PLAN WOOD DOORS CNC-1 SEALED CONCRETE MFG: SHERWIN WILLIAMS COLOR: CITYSCAPE SW7067 FINISH: EGGSHELL FL O O R T I L E RESTROOM TILETL-1 VI N Y L LVT-1 LUXURY VINYL TILE (FIELD) MFG: ARMSTRONG PATTERN: PARALLEL USA 12 COLOR: EVENING SHADOW J5102 SIZE: 6" X 48" X 0.08" INSTALLATION: ASHLAR RESTROOM FLOOR TILE TO CPT - SCHLUTER, RENO U LVT TO CPT - JOHNSONITE SLT- 20-A IN COLOR 20 CHARCOAL WALL TILE (RESTROOM WALL TILE) B-2 CA R P E T CPT-1 CARPET TILE (OPEN OFFICE) MFG: INTERFACE PATTERN: OPEN AIR 418 COLOR: 107044 NICKEL SIZE: 20" X 20" INSTALLATION: ASHLAR CONTACT: JACLYN DAVIS, 314.660.2372 JACLYN.DAVIS@INTERFACE.COM CONTACT: JOANNA WHITTAKER, 314.629.0125 JOANNA.WHITTAKER@DALTILE.COM MFG: DALTILE PATTERN: CHOICE COLOR: IRON CS23 SIZE: 12" X 24" INSTALLATION: 33% OFFSET GROUT: TEC POWER GROUT, MATCH TILE MFG: CROSSVILLE PATTERN: AMAYA WOOD COLOR: WALNUT SIZE: 6" X 24" INSTALLATION: 33% OFFSET GROUT: TEC POWER GROUT, WARM TAUPE 973 CONTACT: NIKKI STELLOH 314.327.9764 Nikki.Stelloh@VirginiaTile.com FINISH: MATTE 6" COVE BASE MFG: TARKETT COLOR: 20 CHARCOAL P-3 PAINT - HM DOORS & FRAMES MFG: SHERWIN WILLIAMS COLOR: PEPPERCORN SW7674 FINISH: ENAMEL ACOUSTICAL CEILING TILEACT-1 SIZE: 24" X 48", ANGLED TEGULAR 15/16" MFG: ARMSTRONG PATTERN: DUNE SECOND LOOK TA10.1 FINISH SPECIFICATIONS SHEET NUMBER JOB NO : GA1054 PA : MLK DATE : 1/8/2024 REVISIONS AR C H I T E C T CO N T R A C T O R CO N S U L T I N G E N G I N E E R S EL E C T R I C A L : PL U M B I N G : ME C H A N I C A L : 79 3 0 C L A Y T O N R D . S T E 3 0 0 RI C H M O N D , H E I G H T S 6 3 1 1 7 (P ) 3 1 4 - 8 2 2 - 5 1 9 1 WW W . G M A - A R C H I T E C T S . C O M THIS DESIGN AND THESE DRAWINGS ARE THE PROPERTY OF GMA ARCHITECTS, INC. NO PART OF THIS WORK MAY BE REPRODUCED WITHOUT PRIOR WRITTEN PERMISSION FROM GMA ARCHITECTS, INC. VE N T U R E M E C H A N I C A L I N C . 16 4 4 W C R O S B Y R O A D CA R R O L L T O N , T X 7 5 0 0 6 97 2 . 8 7 1 . 1 3 0 0 HU R S T E L E C T R I C C O . 22 9 W . H U R S T B L V D . HU R S T , T X 7 6 0 5 3 81 7 . 2 6 8 . 3 0 0 0 PR O J E C T AR C O / M U R R A Y D E S I G N B U I L D 49 2 5 G R E E N V I L L E A V E # 9 1 5 DA L L A S , T X 7 5 2 0 6 21 4 . 3 7 7 . 6 6 8 1 PR O J E C T S W A N S O N 36 4 2 E U L E S S - G R A P E V I N E R O A D , S U I T E 1 0 0 GR A P E V I N E , T X AO S E N G I N E E R I N G 50 2 0 T E N N Y S O N P A R K W A Y PL A N O , T X 7 5 0 2 4 21 4 . 4 3 2 . 3 0 3 0 FOR RECORD SET 12.18.2024 OFFICE FINISH FLOOR PLAN2 TA10.2 SCALE: 1/4" = 1'-0" 106 UNISEX RR 105 UNISEX RR 104 JANITOR 103 OPEN OFFICE 107 BREAKROOM 108 UNISEX RR 110 IT CLOSET P Q CNC-1 P-1 B-1 CNC-1 P-1 B-1 FRP-1 FRP-1 FRP-1 FRP-1 FRP-1 FRP-1 FRP-1 FRP-1 CNC-1 P-1 B-1 LVT-1 P-1 B-1 109 UNISEX RR TL-1 P-1 WT-1 WT-1 WT-1 WT-1 WT-1 WT-1 WT-1 WT-1 P-2 P-2 P-2 P-2LVT-1 P-1 B-1 LVT-1 P-1 B-1 CPT-1 P-1 B-1 B-2 B-2 200 ELECTRICAL ROOM 300 FIRE PUMP ROOM B-2 B-2B-2 H FINISH FLOOR PLAN (ELECTRICAL AND FIRE PUMP ROOM)1 TA10.2 SCALE: 1/4" = 1'-0" 22'-0 1/4" 8' - 1 3 / 4 " TL-1 P-1 P-1 P-1 P-1P-1 P-1 FRP-1 FRP-1 6 A B C D E F G H J K L M N P 1 2 3 4 5 6 Q NOT IN SCOPE KEY PLAN SCALE: NTS AREA OF WORK 1 TL-1 WT-1 WT-1 @ 8' AFF PT-2 ABOVE TA10.2 OFFICE FINISH FLOOR PLAN SHEET NUMBER JOB NO : GA1054 PA : MLK DATE : 1/8/2024 REVISIONS AR C H I T E C T CO N T R A C T O R CO N S U L T I N G E N G I N E E R S EL E C T R I C A L : PL U M B I N G : ME C H A N I C A L : 79 3 0 C L A Y T O N R D . S T E 3 0 0 RI C H M O N D , H E I G H T S 6 3 1 1 7 (P ) 3 1 4 - 8 2 2 - 5 1 9 1 WW W . G M A - A R C H I T E C T S . C O M THIS DESIGN AND THESE DRAWINGS ARE THE PROPERTY OF GMA ARCHITECTS, INC. NO PART OF THIS WORK MAY BE REPRODUCED WITHOUT PRIOR WRITTEN PERMISSION FROM GMA ARCHITECTS, INC. VE N T U R E M E C H A N I C A L I N C . 16 4 4 W C R O S B Y R O A D CA R R O L L T O N , T X 7 5 0 0 6 97 2 . 8 7 1 . 1 3 0 0 HU R S T E L E C T R I C C O . 22 9 W . H U R S T B L V D . HU R S T , T X 7 6 0 5 3 81 7 . 2 6 8 . 3 0 0 0 PR O J E C T AR C O / M U R R A Y D E S I G N B U I L D 49 2 5 G R E E N V I L L E A V E # 9 1 5 DA L L A S , T X 7 5 2 0 6 21 4 . 3 7 7 . 6 6 8 1 PR O J E C T S W A N S O N 36 4 2 E U L E S S - G R A P E V I N E R O A D , S U I T E 1 0 0 GR A P E V I N E , T X AO S E N G I N E E R I N G 50 2 0 T E N N Y S O N P A R K W A Y PL A N O , T X 7 5 0 2 4 21 4 . 4 3 2 . 3 0 3 0 FOR RECORD SET 12.18.2024