DFW West Logistics_Fire Alarm As Builts_12.23.24 (1)
SCOPE: THIS PROJECT IS A SPRINKLER MONITOR SYSTEM IN A NEW GROUP S BUILDING. A NEW AUTOCALL 4007ES ADDRESSABLE FIRE ALARM CONTROL PANEL WILL BE INSTALLED WITH AUTOCALL PERIPHERALS AND AUTOCALL NOTIFICATION DEVICES. ALL EQUIPMENT WILL BE INSTALLED IN ACCORDANCE WITH LOCAL AND STATE CODES AND STANDARDS. GENERAL NOTES: 1. TYPE OF CONSTRUCTION: TENANT IMPROVEMENT 2. WIRING METHOD: EXPOSED PLENUM RATED UNLESS NOTED OTHERWISE 3. SLC, CLASS A 4. NOTIFICATION CIRCUITS, CLASS B 5. PRIMARY POWER SHALL BE A DEDICATED CIRCUIT 6. EXTERIOR WEATHERPROOF HORN -STROBE TO BE LOCATED ABOVE THE FDC AND OPERATE ON WATER FLOW ALARM ONLY AND WILL BE NON-SILENCEABLE WHILE WATER IS STILL FLOWING THROUGH FIRE SPRINKLER SYSTEM. 7. AN APPROVED SET OF "AS -BUILT" PLANS AND OTHER DOCUMENTS REQUIRED BY NFPA AND IFC SHALL BE POSTED AT FACP IN AN APPROVED LABELED DOCUMENT BOX. 8. BREAKER FOR FIRE ALARM CONTROL PANEL AND ALL POWER SUPPLIES SHALL BE MARKED WITH AN APPROVED KIT. FOR THIS PROJECT IT IS A PART OF THE E120-GV SURGE PROTECTION KIT (SEE DATA SHEET). 9. ALL FACP & POWER SUPPLY CIRCUITS SHALL HAVE APPROVED BREAKER LOCK -OUTS INSTALLED. 10. FIRE ALARM CONTROL PANEL AND ALL POWER SUPPLIES SHALL BE LABELED INSIDE WITH THE CIRCUIT BREAKER # AND LOCATION. 11. EACH RISER & OTHER VALVES SHALL HAVE THEIR OWN SPECIFIC TAMPER SIGNALS. 12. EACH RISER SHALL HAVE THEIR OWN SPECIFIC WATER FLOW SIGNAL. 13. TEXAS FIRE MARSHAL'S INSTALLATION CERTIFICATE SHALL BE FILLED OUT & POSTED AT THE FACP. 14. PRIMARY POWER TO BE PROVIDED FROM A DEDICATED 120V CIRCUIT (BY OTHERS) SECONDARY POWER TO BE PROVIDED BY 2 12V 7AH LEAD -ACID SEALED BATTERIES. CIRCUIT TO BE CLEARLY MARKED AS BEING FOR THE FACP OR OTHER TERMINAL EQUIPMENT. AIM ' AIM AIM AIM AIM RISER #1-2 SCALE: 1/8" = 1' CAUSE AND EFFECT: 1. SMOKE DETECTORS ACTIVATES GENERAL ALARM 2. PULL STATIONS ACTIVATES GENERAL ALARM 3. WATER FLOW ACTIVATES GENERAL ALARM 4. WATER FLOW ACTIVATES EXTERIOR AV P1-N1-01, NON SILENCABLE 5. VALVE TAMPER MONITOR ACTIVATES SUPERVISORY 6. EXHAUST FANS SHUT DOWN ON FIRE ALARM /WATERFLOW. 7. NOTIFICATION DEVICES ACTIVATE ON GENERAL ALARM 8. ALARM, SUPERVISORY, AND TROUBLE TO REPORT TO CENTRAL STATION MONITORING VIA CONTACT ID DRAWING INDEX: F1.1 OVERALL SPRINKLER MONITORING SYSTEM LAYOUT/DETAILS P1 FIRE ALARM CONTROL PANEL H -"-i BEOICATE0121V G 20AMPCIRCUIT DACT•001 CELLULAR COMM 1 1.1 11.2 POWER PUMP RUNNING • .AIM AIM 11.3 0PHASE REV AIM Li-4 R 11.5 1_1.6 11.7 OEXHAUTFAN W LOOP TMP TST FOR TMP AA AIM Ll-20 Ll-21 Ll-22 JUNCTION FLOW TMP FLOW BOX AIM/ AABM/ Ll-23 TMP Lt•24 Lt•25 AIM S/ LI.8 11.9 Ll•10 Ll-11 Ll•12 PRV TMP PF CNTRL TMP OS&Y TMP FP BYPASS TMP FLOW A M M AIM �M� AIM/ I _,�..�, n m D, r C :AIM' AIM AIM - 'AOM AIM AIM " AIM AIM AIM' AIM ,,AIM " MAIM AIM ' AIM' AIM, FIRE PUMP ROOM/RISER #3-4 SCALE: 1/8" = 1' OVERALL SPRINKLER MONITORING SYSTEM LAYOUT SCALE: N.T.S. Ll•14 0FLOW AIM LI.15 TMP AIM Ll-16 Ll-17 Ll-18 Ll-19 FLOW TMP FLOW TMP JUNCTION MA M AIM AIM BOX AIM. AIM AIM.. AIM RISER #5-6 SCALE: 1/8" = 1' DEVICE LEGEND SYMBOL QTY MANUFACTURER PART NO DESCRIPTION 4007ES RED WITH A 3 A, CLASS B, IDNAC SLC FOR UP TO 127 ADDRESSABLE NOTIFICATION APPLIANCES, AND A rFAC-1 1 AUTOCALL A007-9201 OUTPUT POWER SUPPLYIBATTERY CHARGER; INCLUDES IDNET+COMMUNICATIONS FOR 100 ADDRESSABLE POINTS 7 NAPCO SLE-LTEVI-FIRE DUAL PATH COMMUNICATOR, CELLULAR WOR IP. CONNECTED BY VERIZON LTE"'' ASS, ADDRESSABLE MANUAL STATION, DOUBLE ACTION, PUSH OF 1 AUTOCALL A4099-9006 OPERATION, ENGLISH Q 22 AUTOCALL A4090-9001 IDNET ADDRESSABLE SUPERVISED MODULE IAM R 1 AUTOCALL A4090-9002 RELAYIAM O 1 AUTOCALL A4098-9714 WIA4098-9792 TRUEALARM PHOTOELECTRIC SMOKE DETECTOR W/TRUEALARM SENSOR STANDARD BASE 1 AUTOCALL A49AV-APPLW-0 WALL MOUNT WEATHERPROOF VISIBLE AND AUDIBLENISIBLE NOTIFICATION APPLIANCES, SPECIFY WP COVER SS 120v 1 SPACE AGE ELECTRONICS E120V-GT HYBRID SURGE PROTECTION DEVICE CABLE AND WIRE LEGEND LABEL PART NO AWG RESISTANCE (OIKFT) DESCRIPTION TOTAL LENGTH L 1612 FPLR (SLC) 16 489 2 COND, SOLID COPPER FPLR ADDRESSABLE 1017' T RJ-11 22 1614 4 COND, UNSHIELDED COMMUNICATIONS CABLE 1' N 1412 FPLP/R (NAC) 14 3 07 2 CORD. SOLID COPPER FPLPIR ANALOG UNSHIELDED 17' PANEL P1 (A007-9201) BATTERY CALCULATION (SECONDARY POWER SOURCE REQUIREMENTS) PANEL POWER SUPPLY MAX CURRENT =4A TOTAL USED CAPACITY (IN ALARM) = 0413A (10 33 %) STANDBY CURRENT (AMPS) SECONDARY ALARM CURRENT (AMPS) CITY PART NO. DESCRIPTION CURRENT DRAW (A) TOTAL (A) CURRENT DRAW (A) TOTAL PANEL COMPONENTS 1 A007-9201 CPU CPU Assembly 018 0.18 0185 0.185 i A007-9806 SDACT Module for Point or Event Reporting 0.03 0.03 0.04 0.04 CIRCUIT SYMBOL QTY PART NO DESCRIPTION CURRENT DRAW (A) TOTAL (A) CURRENT DRAW (A) TOTAL (A) Dual Path Communicator, Cellular P1•DACT 0 1 SLE-LTEVI-FIRE &tor IP, connected by Venzon 0 0 0 0 LTE'1, ASS 22 A4090-9001 IDNet Addressable Supervised 0,0008 0.0176 0001 0.022 Module IAM I O R 1 A4090-9002 Relay IAM 0,0008 0.0008 0 001 0.001 O 1 A4098-9714 w1A4098-9792 TrueAlarm Photoelectric Smoke Detector wlTrueAlarm Sensor 00008 0.0008 0,001 0.001 P1•Lt Standard Base �F 1 A4099-9006 Addressable manual station, Double Action. Psh operation. 0,0008 0.0008 0 001 0.001 English © 1 CLASS A RETURN 0 0 0 0 Wall Mount Weatherproof Visible P1•N1 �WP 1 A49AV-APPLW-0 and AudibleNlsible Notification 00008 0.0008 0163 0.163 App,ances. Specify Cover 75cd TOTAL STANDBY (A) 0.2308 TOTAL ALARM (A) 0.413 REQUIRED STANDBY TIME = 24 HOURS REQUIRED ALARM TIME = 5 MINUTES SECONDARY STANDBY LOAD (A) 0.2308 24 5,54 SECONDARY ALARM LOAD (A) 0A13 ' 008 0.03 STANDBY AND ALARM SUBTOTAL (AMP HOURS) 5.57 BERATING FACTOR 1.2 SECONDARY LOAD REQUIREMENTS (AMP HOURS) 6.69 PROVIDE (2) 12V 7AH BATTERIES 'BATTERY BOX SIZE CAPACITY NOT SPECIFIED, REFER TO MANUFACTURER DOCUMENTATION ( CIRCUIT SETTINGS TOTALS )Starting Calculation Voltage 29 Max. Voltage Drop, 0.02 P1 N1 POINT-TO-POINT REPORT ( Min. Operational Voltage: 16 End Of Line Voltage: 28,98 Max. Circuit Current (A): 3 Voltage Drop Percent 0.06 % Wire Resistance(OIkFtL 307 Total Circuit Current (A) 0.163 Circuit Wiring Properties:'V 1412 FPLPIR (NAC)14 AWG, 2 Cond, Solid Copper FPLPIR Analog Unshielded Total Circuit Length Ed, 17 Spare Current (A): 2.837 Distance measured using drawn segment lengths with 10 00 % additional length calculated Total Circuit Resistance (0): 0103119 Spare Current (A) Percent: 94.57 % Device Label Part No, Description Device Current (A) Remaining Current (A) Dist. From Previous (Ft) Resistance From Previous Voltage Drop From Voltage At Device Total Voltage Drop Voltage Drop Percent (Q) Previous Wall Mount Weatherproof Visible and AudibleNlsible NI.1 A49AV-APPLW-0 Notification Appliances. 0.163 0.163 17 0.103119 0.02 28.98 0.02 0.06 % Specify Cover 75cd Calculation Methods: Resistance From Previous (0) = Wire Resistance (OIFf x 2 x Dist From Previous (Fh Voltage Drop From Previous = Resistance From Previous (0) x Remaining Current (A) MIN291 02 M_ 61 P. •no] j l APPLICABLE CODES: .A .d 2015 -• AS AMENDED BY THE CITY OF A' 2 FOR SUBMITTALF-1 RECORD DRAWINGS i I have reviewed these plans and W ❑X certify that they comply with the applicable codes (� and standards; Or ❑ certify they were copied from sealed engineering (� plans and any violations of the applicable codes or standards are specifically noted on these plans. 0 Q ry NORTH TEXAS FIRE, LLC. Q LO _o >� 4050 SANDSHELL DRIVE LL_I W FORT WORTH, TX 76137 Q x 817-720-7000 ACR-2625711 � I- �V)z v� Lij O�W APS Licensee Signature License # APS-1743780 W Q ry RYAN S. MASTERS 3/12/2024 Q APS Printed name Date cO (� r-9 SHEET TITLE- U W OVERALL SPRINKLER MONITORING __D SYSTEM LAYOUT/DETAILS O n F1.1 DRAWN BY: RSM I SHEET 1 OF 1