Loading...
HomeMy WebLinkAboutItem 03 - Grapevine Mills MallTO- HONORABLE MAYOR, CITY COUNCIL MEMBERS, AND THE PLANNING AND ZONING COMMISSION FROM- BRUNO RUMBELOW, CITY MANAGER ERICA MAROHNIC, DIRECTOR, PLANNING SERVICES MEETING DATE- JANUARY 21, 2025 SUBJECT- PLANNING SERVICES TECHNICAL REPORT OF CONDITIONAL USE APPLICATION CU24-51, GRAPEVINE MILLS MALL EV CHARGING STATIONS �I I ----I � I I I - - - - - - - - - - - --Ii — Grapevine I DLake t I �a I 1 4 yak' I.H 1635 �1 a Northwest j APPLICANT- Brian Powers — Black & Veatch PROPERTY LOCATION AND SIZE - ads % 5��`I The subject property is located at 3000 Grapevine a'00Mills Parkway, platted as Block 1, Lot 1R3, ' SDFW Grapevine Mills Addition, Phase I. The addition 'y 3 I Hall -Johnson 36o Airport a contains 136.92 acres and has approximately 2,388 I T— —� o I feet of frontage along State Highway 26 and ID -_ - Glade Rd. approximately 1,834 feet of frontage along � �, I _� - Grapevine Mills Parkway. The site is located 3: adjacent to the northeast corner of the mall, between Fieldhouse USA and Meow Wolf, approximately 340 feet west of East Grapevine Mills Circle. REQUESTED CONDITIONAL USE AND COMMENTS - The applicant is requesting a conditional use permit to amend the previously approved site plan CU24-01 (Ord. 2024-044) for a planned commercial center in excess of 1,000,000 square feet of gross, leasable space. This request is specifically to add three, public use. freestanding Level 3 electric vehicle (EV) charging stations to the existing mall parking lot. On January 16, 2024, City Council approved AM23-02 (Ord. 2024-006) to create new definitions, allow electric vehicle charging stations as a conditional use, and create use - specific standards, relative to electric vehicle charging stations. With this request, the applicant proposes installing three Level 3 (Rapid Charge), electric vehicle (EV) charging stations on the subject site. The EV chargers will be approximately 8.2 feet in height, located adjacent to the northeast corner of the mall between Fieldhouse USA and Meow Wolf, approximately 340 feet west of East Grapevine Mills Circle. Twelve existing parking spaces will be converted into six EV charging stalls, including three EV charging pedestals and an equipment area. The three EV chargers will charge two vehicles at a time. The stalls and equipment are adjacent to two existing driving aisles of head -to -head parking spaces. An 8-foot equipment enclosure is proposed for the EV charging equipment, in addition to one 18-foot light pole and security camera. The EV chargers will be available 24 hours a day. The total number of parking spaces required is 9,117. The total number of parking spaces provided is 10,219. All other use -specific standards in Subsection 42. 1. Electric vehicle (EV) charging stations, are met. PRESENT ZONING AND USE: The subject site was zoned "L-1" Light Industrial District prior to the 1984 City-wide rezoning at which time the subject site was rezoned to "HCO", Hotel/Corporate Office and "PID", Planned Industrial Development. The subject property was rezoned to "CC", Community Commercial with (Z95-13) on October 17, 1995. The property is currently zoned "CC", Community Commercial District with a planned commercial center in excess of 1,000,000 square feet of gross leasable space designation and is developed as the Grapevine Mills Mall. On January 16, 1996, City Council approved CU95-36 (Ord. 1996-05) for development of a planned commercial center in excess of 1,000,000 square feet of gross leasable area. On August 6, 1996, City Council approved ADD96-01 (Res. 1996-34) to CU95-36 for 8 public entryway features. On September 17, 1996, City Council approved CU96-26 (Ord. 1996-79) to revise the site layout, the ring road configuration, and access to residential properties to the west. On February 18, 1997, City Council approved CU97-05 (Ord. 1997-09) to allow alcoholic beverage sales (Sega Game Works) and amend the site layout. On February 18, 1997, City Council approved CU97-06 (Ord. 1997-11) to amend the previously approved site plan for development of a theater (AMC Theater) with 30 screens. • On February 18, 1997, City Council approved SU97-04 (Ordinance 1997-10) to allow skill -oriented games in excess of eight (8) machines and two (2) billiard tables. • On March 18, 1997, City Council approved CU97-13 (Ord. 1997-28) to allow for alcoholic beverage sales in conjunction with a restaurant (The American Wilderness Experience). CU24-51 2 On April 15, 1997, City Council approved CU97-18 (Ord. 1997-40) to allow for alcoholic beverage sales in conjunction with a restaurant (Rainforest Cafe). On June 3, 1997, City Council approved CU97-29 (Ord.1997-55) to allow additional signage for the entire Grapevine Mills Mall project including the outparcel areas. On July 1,1997, City Council modified CU97-29 to allow for an 80-foot entertainment globe. On June 19,1997, City Council approved CU97-25 (Ord. 1997-57) to allow for alcoholic beverage sales in conjunction with a restaurant (Tres Hombres) located in the outparcel area. On July 15, 1997, City Council approved CU97-36 (Ord. 1997-72) to allow for the development of a retail use in the outparcel area (Michael's Arts and Crafts Store). On August 19,1997, City Council approved CU97-42 (Ord. 1997-92) to allow the development of a retail tire store in the outparcel area (Discount Tire). On November 18, 1997, City Council approved Z97-22 (Ord. 1997-125) to rezone 11.825 acres from "PCD", Planned Commerce Development District and 26.43 acres from "HCO", Hotel/Corporate Office District to "CC", Community Commercial District for the development of Bass Pro Shops Outdoor World and Embassy Suites Hotel. The 38.255-acre Phase 2 development was incorporated into the overall Grapevine Mills planned commercial center located to the southeast of the mall proper across State Highway 26 and bordered also by the southbound service road of State Highway No. 121 and Bass Pro Drive (Bethel Road). On November 18, 1997, City Council approved CU97-60 (Ord. 1997-126) and CU97-61 (Ord. 1997-127) to incorporate Bass Pro Shops Outdoor World and Embassy Suites Hotel into the Grapevine Mills planned commercial center and also allow for on -premises consumption of alcoholic beverages and seven 40-foot pole signs. On November 18, 1997, City Council approved CU97-62 (Ord. 1997-128) to amend the previously approved site plan for a 39,870 square foot retail furniture store (Rooms to Go). On November 18, 1997, City Council approved CU97-63 (Ord. 1997-129) to amend the previously approved site plan for a 3,822 square foot restaurant (Chick Fil A). On November 18, 1997, City Council approved CU97-64 (Ord. 1997-130) which allowed for off -premise consumption of alcoholic beverages (wine only) for a lease space within the mall proper (Baxter's). CU24-51 3 On December 19, 1997, City Council approved CU97-68 (Ord.1997-147) for the development of a 3,855 square foot heath care facility (Primacare) in the Phase 1, outparcel area. On January 20, 1998, City Council approved CU97-75 (Ord. 1998-10) to amend the mall signage plan for wall signage associated with outparcel tenants. On January 20, 1998, City Council approved CU97-76 (Ord. 1998-11) to amend the site plan for a 10,095 square foot restaurant (Cozymel's) in the Phase 1, outparcel area. On February 3, 1998, City Council approved CU98-03 (Ord. 1998-17) to amend the floor plan for Dick Clark's American Bandstand restaurant. On February 3, 1998, City Council approved CU98-07 (Ord. 1998-40) to allow on - premise consumption of alcoholic beverages in conjunction with a restaurant (Corner Bakery). On June 16, 1998, City Council approved CU98-21 (Ord. 1998-74) to amend the floor plan for a restaurant (American Wilderness) with on premise consumption of alcohol beverage in the outparcel area. On June 16, 1998, City Council approved a request for temporary parking areas at Anchor Pads A and B through January 15, 1999. On September 15, 1998, City Council approved CU98-47 (Ord. 1998-116) to amend the floor plan for Cozymel's in the outparcel area of the Grapevine Mills Mall. On September 15, 1998, City Council approved CU98-48 (Ord. 1998-117) to establish a restaurant (MJ's Chop House/Mason Jar) with on premise consumption of alcohol beverage in the outparcel area. On September 15, 1998, City Council approved CU98-49 (Ord. 1998-118) to allow for canopy extensions over the main entrance and ticket window areas of the AMC Theater complex at Grapevine Mills. On October 20, 1998, City Council approved CU98-57 (Ord. 1998-130) to allow for the development of a restaurant (Black -Eyed Pea) with alcohol beverage sales in the Phase 1, outparcel area. On November 17, 1998, City Council approved CU98-59 (Ord. 1998-135) to allow alcoholic beverage sales throughout the premises for "special events" at Sega Gameworks. CU24-51 4 On December 15, 1998, City Council approved CU98-63 (Ord. 1998-151) to allow for a 6-story, 121-room hotel (Ameri Suites) in the outparcel area. On February 2, 1999, City Council approved CU98-79 (Ord. 1999-17) to allow a revision to the floor plan for Sega Gameworks. On March 23, 1999, City Council approved CU99-12 (Ord. 1999-16) to allow revisions to Anchor "G" specifically building area reduction from 35,790 square feet to 26,500 square feet for Iguana Ameramex. On April 20, 1999, City Council approved CU99-17 (Ord. 1999-61) for a restaurant in the mall proper (Jekyll and Hyde) with on -premise alcoholic beverage sales (beer, wine, and mixed drinks). On May 18, 1999, City Council approved CU99-27 (Ord. 1999-83) to allow for the construction of a partial stone wall with trellis along the rear elevation of an existing restaurant (Cozymel's). On July 20, 1999, City Council approved CU99-41 (Ord. 1999-109) for a 7,189 square foot restaurant (Bennigan's) with on -premise consumption of alcoholic beverages (beer, wine, and mixed drinks) in the Phase 1, outparcel area. On November 16, 1999, City Council approved CU99-60 (Ord. 1999-163) to amend the previously approved site plan for a mall expansion Anchor "A." On November 16, 1999, City Council approved CU99-61 (Ord. 1999-164) to amend the previously approved parking layout for Rooms -To -Go. On November 16, 1999, City Council approved CU99-63 (Ord. 1999-165) for a restaurant (Trail Dust) with on -premise alcohol beverage sales in the outparcel area. On December 7, 1999, City Council approved CU99-71 (Ord. 1999-178) to allow for the development of a 4-story, 105-room hotel (Hawthorn Suites) in the Phase 1 outparcel area. On April 18, 2000, City Council approved C000-16 (Ord. 2000-43) to allow for changes to the exterior elevations of Anchor "A." On June 20, 2000, City Council approved S000-07 for 30 redemption/coin-operated games at the main Texas entrance of the Grapevine Mills Mall. On August 15, 2000, City Council approved C000-21 (Ord. 2000-83) to allow for a four story 114-room hotel (SpringHill Suites) CU24-51 5 On December 19, 2000, City Council approved C000-67 (Ord. 2000-127) to allow for the development of a restaurant with a drive-thru window, Steak-n-Shake, in the outparcel area. On December 19, 2000, City Council approved C000-68 (Ord. 2000-128) to allow for the development of a business services/reproduction facility (Kinko's) in the outparcel area. On July 17, 2001, City Council approved CU01-38 (Ord. 2001-56) to allow for a 32,786 square foot expansion to the mall proper at what was known as the "Texas" entrance, for a Neiman Marcus retail concept known as Last Call. On October 16, 2001, City Council approved CU01-51 (Ord. 2001-78) and Special Use Request SU01-07 to allow for a restaurant (Chuck-E-Cheese) with video games in excess of eight machines in the outparcel area. On September 26, 2001, the Site Plan Review Committee (SPRC) approved CU01- 54 for minor revisions to the site plan of a department store (Neiman Marcus) located at the mall proper to allow for a power generator and landscape island. On May 21, 2002, City Council approved CU02-17 (Ord. 2002-37) to allow for a 20- foot pole sign for Rainforest Cafe immediately south of Neiman Marcus Last Call. On June 18, 2002, City Council approved CU02-16 (Ord. 2002-47) for an expansion of the mall proper to allow for the development of an indoor and outdoor skating park (ESPN Skate Zone). On June 18, 2002, City Council approved CU02-21 (Ord. 2002-50) to allow for an expansion of the alcohol consumption area to include the entire floor area within Sega Game works. On October 15, 2002, City Council approved CU02-43 (Ord. 2002-79) to amend the previously approved site plan of a former restaurant (Black -Eyed -Pea) to allow for modifications to the floor plan for a new restaurant (Blue Goose). On May 20, 2003, City Council approved CU03-14 (Ord. 2003-33) to amend the previously approved site plan to allow modifications associated with the Springhill Suites hotel in the outparcel area. On July 15, 2003, City Council approved CU03-19 (Ord. 2003-47) for the development of a tunnel -based aquarium (Underwater World) with the possession, storage, retail sale, and on -premise consumption of alcoholic beverages (beer, wine, and mixed drinks) in conjunction with a restaurant in the outparcel area. CU24-51 6 On December 16, 2003, City Council approved CU03-43 (Ord. 2003-79) and SU03- 06 to allow the possession, storage, retail sale, and on -premise consumption of alcoholic beverages (beer, wine, and mixed beverages) in conjunction with a restaurant/dance club (Midnight Rodeo/Hondo's Grill) and to allow the use of three pool tables. On December 16, 2003, City Council approved CU03-47 (Ord. 2003-82) to allow for a restaurant (Ritzy's) in the outparcel area. On January 26, 2005, SPRC approved CU05-01 to allow minor modifications to the exterior and interior of an existing restaurant (Love and War in Texas) On March 15, 2005, City Council approved CU05-08 (Ord. 2005-19) to allow for on - premise alcohol beverage sales at the Chuck-E-Cheese restaurant in the outparcel area. • March 15, 2005, City Council approved CU05-09 (Ord. 2005-20) to allow an approximate 8,000 square foot expansion (Children's World) near the "Tornado" entrance to the mall. On July 25, 2006, SPRC approved CU06-33 to allow for the addition of 1,000 square feet of office space. On November 7, 2006, City Council approved CU06-42 (Ord. 2006- 79) for a car wash service (Pronto Wash) adjacent to Neiman Marcus Last Call. On November 21, 2006, City Council approved CU06-52 (Ord. 2006-83) to allow a 26,325 square foot retail structure located between Rooms to Go and Chuck E. Cheese in the outparcel area On October 21, 2008, City Council approved CU08-25 (Ord. 2008-57) for a restaurant (Daan Sushi) with alcoholic beverage sales between Rooms to Go and Chuck E. Cheese in the outparcel area. On September 15, 2009, City Council approved CU09-24 (Ord. 2009-39) for an existing restaurant (Love and War in Texas) to allow outside dining with outdoor speakers for live music performances. On November 17, 2009, City Council approved CU09-37 (Ord. 2009-51) to allow for changes to the floor plan and building elevations, as well as adding outdoor dining and converting the former Bennigan's restaurant to a new Applebee's restaurant. On December 21, 2010, City Council approved CU10-25 (Ord. 2010-70) to modify site signage. CU24-51 7 On January 19, 2011, City Council approved CU10-25A (Ord. 2010-70) to revise the site signage package for 20 existing signs and one wall sign. On July 21, 2015, City Council approved CU 15-21 (Ord. 2015-038) to allow for the possession, storage, retail sales and on -premise consumption of alcoholic beverages (beer, wine, and mixed beverages) in conjunction with an existing hotel. On November 17, 2015, SPRC approved CU15-46 to revise the previously approved sign package with new way finding signs. On January 19, 2016, City Council approved CU 15-48 (Ord. 2016-05) to amend the previously approved site plan to revise the building elevations, floor plan, allow outside dining and outside speakers in conjunction with a restaurant (Blue Goose Cantina). On September 15, 2020, City Council approved CU20-17 (Ord. 2020-44) to amend the previously approved site plan to allow the possession, storage, retail sales and on -premise consumption of alcoholic beverages (beer and wine only) in conjunction with an existing restaurant (Kimsu Sushi). On June 9, 2022, SPRC approved CU22-20 to modify the building's exterior elevation to install a parapet -mounted sign above the existing height of Macy's Backstage. On June 9, 2022, SPRC approved CU22-23 to modify the north and east exterior elevations that includes a mural, a new tiered entry feature, and enhancements to the building's facade for new tenant (Meow Wolf). On March 19, 2024, City Council approved CU24-06 (Ord. 2024-025) to allow the possession, storage, retail sale of on and off premise consumption of alcoholic beverages (beer, wine, and mixed beverages) in conjunction with an existing cafe inside of Meow Wolf. On May 21, 2024, City Council approved CU24-01 (Ord. 2024-044) to split the existing Burlington Coat Factory, suite 343 into two separate suites for a new retail tenant, changes in building elevations for a new main entry, and to revise the parking lot to include seven additional ADA parking spaces, a crosswalk, a 5-foot sidewalk and loading dock. SURROUNDING ZONING AND EXISTING LAND USE: NORTH: "HCO", Hotel/ Corporate Office District, "R-MF-2", Multi -family District, & "PID", Planned Industrial Development — Cross Creek Apartments and Cross Creek Ranch CU24-51 8 SOUTH: "HCO", Hotel/ Corporate Office District — Hilton Hotel and Austin Ranch EAST: "CC", Community Commercial District — Fellowship Church WEST: "R-MF", Multi -family District and "CC", Community Commercial District — Enclave at Grapevine Apartments and Kriya Hotels office building AIRPORT IMPACT: The subject tract is located within Aircraft Sound Exposure "Zone B" Middle Zone of Effect, and "Zone C", Zone of Greatest Effect. The subject tract is located within "Zone B" Middle Zone of Effect as defined on the "Aircraft Sound Exposure: Dallas/Fort Worth Regional Airport Environs" map. In "Zone B", the following uses may be considered only if sound treatment is included in the building design: multifamily apartments, motels, office buildings, movie theatres, restaurant, personal and business services. Single-family residential and sound sensitive uses such as schools and churches should avoid this zone. The applicant's proposal is an appropriate use in this noise zone. MASTER PLAN APPLICATION: Map 2: Land Use Plan of the Comprehensive Master Plan designates the subject property as Commercial/Mixed Use (C/MU) land use. The request is compliant with the Master Plan. THOROUGHFARE PLAN APPLICATION: The Thoroughfare Plan designates this portion of North Grapevine Mills Boulevard as a Type B Major Arterial thoroughfare with a minimum 80-foot right-of-way developed as six lanes with a turn lane. /at CU24-51 9 i p�P,R�N5N�p NOON f t2' 2515t R-MF-2 HCO SUBJECT PROPERTY �® eta ea.n GRpp � PNV\NE 2 1 ¢rg G�5550 G 1 f 1 gg� TH Ga,�5580 1a5� GN POON I7j N5-SaN 356p2� g5a5 1 F--LJ I I I Feet 0 330 660 990 1,320 -1�A1 R -'T E IX S W� E VIN 5 a EV\NE V\N6 j51 B 6TARSANa STRIPES WAY G0,p F ,sw® emam �yySP \ 7 NON O e'ws' BP 'tN o. BP CU24-51; Grapevine Mills Mall EV 3000 Grapevine Mills Parkway Date Prepared: 1/6/2025 This data has been compiled by the City of Grapevine IT/GIS department. various official and unofficial sources were used to gather this information. Every effort was made to ensure the accuracy of this data, however, no guarantee is given or implied as to the accuracy of said data. CONDITIONAL USE PERMIT APPLICATION AND SITE PLAN SET CHECKLISTS Current or if unplatted, proposed subdivision name(s), Gross area of parcel (to nearest tenth of block(s), & lot(s) acre) K I LC�I R3 Clra.pi% i n� mmL mdri. Street frr"ntage & distance to nearest cross street Describe the Proposed Use Electric Vehicle Charging Facility Proposed Zoning Community Commercial Future Land Use Designation Go Existing Zoning Community Commercial Subject Property Address 3000 Grapevine Mills Parkway All Conditional Use Permit Requests are assumed to be complete when filed and will be placed on the agenda for public hearing at the discretion of staff. Based on the size of the agenda, your application may be scheduled to a later date. All public hearings will be opened and testimony given by applicants and interested citizenry. Public hearings may be continued to the next public hearing. Public hearings will not be tabled. Any changes to a site plan approved with a conditional use permit request can only be approved by City Council through the public hearing process. Any application for a change in zoning or for an amendment to the zoning ordinance shall have, from the date of submittal, a period of four months to request and be scheduled on an agenda before the Planning and Zoning Commission and City Council. if after said period of four months an application has not been scheduled before the Commission and Council said application shall be considered withdrawn, with forfeiture of all filing fees. The application, along with the required filing fee may be resubmitted any time thereafter for reconsideration. Delays in scheduling applications before the Planning and Zoning Commission and City Council created by city staff shall not be considered a part of the four -month period. ! have read and understand all of the requirements as set forth by the application for a conditional use permit request and acknowledge that all requirements of this application have been met at the time of submittal. Owner Name Joseph szymaszek Company Grapevine Mills Mall Limited Partnership Address 3000 Grapevine Mills Parkway City Grapevine Email Owner Phone Number 972-724-4910 State Texas Zip Code 76051 NOV 0 4 2024 Planning p Services Department C'VA OL%A 200 S. Main Street • Grapevine, TX 76051 • 817.410.3155 • htt s:/p /bit.ly/GrapevineP[annina Updated June 21, 2024 CONDITIONAL USE PERMIT APPLICATION AND SITE PLAN SET CHECKLISTS Project Representation (check one): ❑ 1 will represent the application myself; OR cr, I hereby designate Brian Powers (Agent) (name of project representative) to act in the capacity as my agent for submittal, processing, representation, and/or presentation of this request. The designated agent shall be the principal contact person for responding to all requests for information and for resolving all issues of concern relative to this request. I hereby certify that I am the property owner of the property and further certify that the information provided on this development application is true and correct. I have selected the above submittal type and representation of my own volition and not at the request of the City of Grapevine. Property Owner's Signature �'1� Date /U/4/)� STATE OF: COUNTY OF: BEFORE ME, a Notary Public, on this day personally appeared (printed property owner's name) the above signed, who, under oath, stated the following: "I hereby certify that I am the property owner for the purposes of this application; that all information submitted herein is true and correct." SUBSCRIBED AND SWORN TO before me, this the day of 20 a(P NOTARY PUBLIC in and for the State of Texas DAWNA PETROSKY Notary Public, State of Texas �` •., v' Comm. Expires 01.22-2028 Notary ID 126594844 Jt�CJt1. Nov 0 4 2074 3 Qml� - eal Planning Services Department 200 S. Main Street • Grapevine, TX 76051 • 817.410.3155 • htt sp Ibit.ly/GrapevinePlannina Updated June 21, 2024 CONDITIONAL USE PERMIT APPLICATION AND SITE PLAN SET CHECKLISTS Project Representative Information (complete if designated by owner) ❑ Engineer ❑ Purchaser ❑ Tenant ❑ Preparer ExOther (specify) Agent for Tenant Name Brian Powers Company Black & Veatch Address 45 Eisenhower Drive, Suite 210 City Paramus State NJ Zip Code 07652 Phone 201-977-1534 Applicant's Signatur _ �� Date ` /e7 le t92 / STATE OF: I �► �_ c,J �'Se �� COUNTY OF: "';F� rc o l--\ 0 BEFORE ME, a Notary Public, on this day personally appeared c f G ct (printed project representative name) the above signed, who, under oath, stated the following: "I hereby certify that I am the applicant for the purposes of this application; that all information submitted herein is true and correct." SUBSCRIBED AND SWORN TO before me, this the o� I day of -p-%,Y . 20 4� DIANA L. SPLIEDT NOTARY PUBLIC NOTARY PUBLIC in and for the State of -Texas STATE OF NEW JERSEY 7 MY COMMISSION EXPIRES APRIL 28, 20ACO If the legal owner of the property is a corporation, company, partnership, or Limited Liability Company, provide a copy of a legal document attached with this application showing that the individual signing this document is a duly authorized partner, officer, or owner of said corporation, partnership, or Limited Liability Company. For any individual or organization who consents to act as an agent for the entity for purposes of receiving any process, notice or demand: Entity Name or File Number: Provide a most recent public information report that includes: IMUMv�li 1. All general partners NOV 0 4 2024 2. File Number 3. Registered agent name W01ASSIGI 4. Mailing address (You may order a copy of a Public Information Report from - ^en.records@cpa.texas.gov or Comptroller of Public Accounts, Open Records Section, PO Box 13528, Austin, Texas 78711 or go to https://mycpa.cpa.state.tx.us/coa/search.do) 4 Planning Services Department 200 S. Main Street a Grapevine, TX 76051 • 817.410.3155 • httr)s://bit.ly/GraoevinePlannina Updated June 21, 2024 Bales, Emma From: Powers, Brian E Sent: Tuesday, October 22, 2024 7:16 AM To: Bales, Emma Cc: Birch, Leslie; Rothermich, Peter, Banning, Adam Subject: FW: Simon Grapevine Mills - Site Location Attachments: 20400063 Fault Current.pdf, 20400063 Field Design.pdf Emma, Please print out the two attachments and entire email string to include with the Grapevine filing on 11/4/24. Thank you. Brian Powers, SSBB, MPM Sr. Land Services Manager Black & Veatch 45 Eisenhower Drive, Ste. 210, Paramus, NJ 07652 (201) 977-1534 w 1 (201) 655-0693 m Building a World of Difference.@ From: Douglas, Charles < > Sent: Monday, October 21, 2024 6:54 PM To: Reichel, Paige >; Folger, Ryan Cc: Stevenson, Bardin ; Birch, Leslie ; Powers, Brian E >; Bacon, Tony Subject: RE: Simon Grapevine Mills - Site Location Caution - External Email: This email originated outside of Black & Veatch. Please do not click links or open attachments unless you recognize the sender and know the content is safe. Confirming here that the design as presented (attached here again for easier reference) works for Oncor. Also, Oncor has performed our loading analysis to confirm that Oncor has capacity to serve the full 1050kW of Electrify America EV charger load on site. Sincerely RECEIVE NOV 0 41024 *** PLEASE NOTE: I will be 000 from 11/09/24 to 11/25/24. *** Charles Douglas III, EIT Oncor I Joint Use Office: 817.215.6306 Cell: 512.925.7935 My Manager: Ryan Folger Cell: 469.984.0396 Email Customer New Service Portal For any residential or commercial serve new projects please follow this link. https://www.oncor. com/SitePaaes/ConstructionAndDevelopment.asax From: Reichel, Paige Sent: Monday, October 21, 202411:54 AM To: Douglas, Charles ; Folger, Ryan > Cc: Stevenson, Bardin Birch, Leslie ; Powers, Brian E < ; Bacon, Tony Subject: FW: Simon Grapevine Mills - Site Location Importance: High Hi Charles, For Grapevine, the AHJ is requesting a written confirmation from Oncor that this project is approved for capacity and design before they will release our job for review. Can you please provide that? Thank you! Paige Reichel Electrify America, LLC / Project Development Manager Mountain Region m: +1(571) 519.1781 1950 Opportunity Way Suite 1500 Reston, VA 20190 electrify amenca Internal From: Sachen, Richard < > Sent: Monday, December 4, 2023 4:08 PM To: Reichel, Paige Cc: Charles Douglas Subject: FW: Simon Grapevine Mills - Site Location Hello Paig,_, This is your site. Richard Sachen Project Development Manager 571-471-8455 (cell) From: Douglas, Charles < > Sent: Wednesday, November 29, 2023 10:15 AM To: Sachen, Richard Cc: Folger, Ryan Subject: [From: External] FW: Simon Grapevine Mills - Site Location CAUTION: This email originated from outside the organization. Do not click links or open attachments unless you recognize the sender and know the content is safe. Richard, Please see the attached Oncor prelim design for your project 220234 — WO 20400063 1000 Grapevine Mills Pkwy Grapevine 76051. Prelim design scope of work is described below, and the fault current information is also attached. Sincerely Charles Douglas III, EIT Oncor f Network Design Office: 817.215.6306 Cell: 512.925.7935 My Manager: Ryan Folger Cell: 469.984.0396 Email: Customer New Service Portal For any residential or commercial serve new projects please follow this link. https://www.oncor.com/SitePacesIConstructionAndDevelopment.aspx From: Douglas, Charles Sent: Wednesday, September 6, 2023 12:25 PM To:'Reichel, Paige' < Cc: Nath, Rajiv Stevenson, Bardin RECEIVED NOV 0 4 2024 weltAu-bk < ; Ryan Folger Subject: FW: Simon Grapevine Mills - Site Location Paige, Please see the attached prelim for your project at 3000 Grapevine Mills Pkwy Grapevine 76051—WO 20400063. High Level Scope of Work: - Oncor to install new utility -owned SWG and pad the SWG sits on - Oncor to install conduit and 1000 kcmil cable from existing SWG to the new SWG (-166') - Customer to install the XFMR pad - Customer to install (2)-4" conduit runs from XFMR pad to new SWG (-130') - Oncor to install 1500kVA XFMR on the pad o NOTE: PTs, CTs, and the meter will be installed by Oncor on the XFMR - Oncor to pull 3phase 1/0 cable from XFMR pad to new SWG (-130') GPS Coordinates: - Proposed new utility SWG location: 32.967219,-97.040328 - Proposed PadMount XFMR Location: 32.967408,-97.040061 Also, please see the attached fault current calculations for your site. If this design looks good to you as is, then please send back an email confirming that you approve of this design. If you believe something needs to change, then feel free to shoot over an email with the amendments that you need and we'll update the design for you. Sincerely Charles Douglas III, EIT Oncor I Network Design Office: 817.215.6306 Cell: 512.925.7935 My Manager: Ryan Folger Cell: 469.984.0396 Email: Customer New Service Portal For any residential or commercial serve new projects please follow this link. https://www.oncor.com/SitePagesIConstructionAndDevelopment.as From: Nath, Rajiv Sent: Wednesday, May 31, 2023 3:23 PM To: Douglas, Charles Subject: Simon Grapevine Mills - Site Location I. PROPOSAL SUMMARY INFORMATION DATE: 7/1 /2024 APPLICANT. Electrify America c/o Brian Powers Black & Veatch 45 Eisenhower Drive Suite 210 Paramus, NJ 07652 Telephone: 201-977-1534 Email: PROPERTY OWNER: Simon Malls REQUEST: Pre -Application Review Meeting (ZOOM Meeting requested) MAP/TAX LOT: 41-307-097 LOCATION: Simon Grapevine Mills Mall 3000 Grapevine Mills Pkwy, Grapevine TX 76051 ZONING: CC — Community Commercial District 0 RECEIVED NOV 0 4 2024 II. PROPOSAL DESCRIPTION Electrify America is establishing a comprehensive, technologically advanced, and customer -friendly charging network to drive Electric Vehicle (EV) adoption by reducing charging anxiety. Electrify America is establishing a network that includes non-proprietary electric vehicle charger stations (EVCS) at sites across the country. Community -based charging station sites such as the one proposed at Simon Grapevine Mills, are installed at workplaces, retail locations (shopping centers, restaurants, etc.), multifamily residential locations, municipal lots, and garages, and in high-speed community depots that will feature fast EV charging. Electrify America's goal is to promote greater Zero -Emission Vehicle (ZEV) adoption by offering an ultrafast and convenient charging network. This will fuel today's EVs, as well as the rapid growth in EV models expected from car companies between now and the late 2020s. Electrify America chargers are available to customers 24 hours a day, 7 days a week. The chargers do not require any attendants or employees and access to the charging stations is via existing roads. Electrify America has a 24-hour help line for troubleshooting and support. The charging station sites will have quarterly maintenance checks by Electrify America. For this project, Electrify America is looking to install this EVCS site on the northeast side of the existing parking lot. The proposed technology will not impact the footprint, parking, lighting, or landscaping of the site. The installation will not impact vehicle or pedestrian access, handicapped parking or truck loading and unloading facilities. The project will provide BTC Gen IV Dispensers and Signet Power Units on a new conduit platform. The attached site plan shows the proposed layout and equipment dimensions. Page,2 July 1, 2024 Proposed Equipment Elevation: V!!ttlCfLYlC! ® tlILOrtIRL VR9➢6OIR56M1m 011lv^l610R6GLTR: C p10P0�PJG1"JRB? i vG"IEIlaLYdlfY1�Y11mMlCLLLI9'YH PIIQiClIYfI1011ll:J PYP� Ypt glGl!! YEiICEWLY dJ' IiN1IPl 'IICPM®Iil!!lY IIIR ICLli1�011CI!/M �, D��LCR� � G �OUlImGtlTIWIpgBOf -� G ! ��� YaeRY Y TtsMIC�tlBI '- . 006.11Y- 6Y11L'T Plan for the proposed EV equipment: o� • � ELO'RM UlC I b ! ti f •• / ,y��,r, f / ♦\ )/I i EVSTM BJRDM T� E7oSTTRG UMERG--I- - :Y .n ../! F �� ,"• / ` WATER LKEPYPJ ♦ ♦ r~:. ` / / wagnwsm POITTM -. - — TREE MV) ♦ ♦ -T / EXMTM • • E70STM FIRE t•:' si:` • Fy�''RY¢ HYDRART • � / Ey 1�'r�E - DaSTL9G FIRE ! ' • / V masnRGALPR6LT Mama STew PARMHGLAT(TYPj NLL7MIJ EMSTMG Y MIT POLE EXMTMGFENCE r SITE W BON NEX RECEIVED NOV 0 4 2024 Page 3 July 1, 2024 uAwL4 -51 Proposed Dispenser and Power Unit: PFCFMWLn"P%Z fn�-..M f,�:» fx � fN-f.-W, f 1� t s Page 4 fX.AEK :"7l:1 flF:Ql�Y' :7{O3'Jf:.XI BRE fErl9fV BiWMI LEG7Wtf z PR-;-,%Ez mff� July 1, 2024 s CONDITIONAL USE PERMIT APPLICATION AND SITE PLAN SET CHECKLISTS PLATTING VERIFICATION. To be filled out by the Public Works & Engineering Department at time of submittal ❑ It has been determined that the property described below does require platting or replatting and the applicant has been instructed on this procedure. R" It has been determined that the property described below is currently platted or does not require platting or replatting at this time. Address of subject property 3000 Q61jy1 M I IL� N-VVY Legal description of subject property ��tacp2J�l��, iV/1,Ils 6A 11. to - Public Works Department Date RECEIVED NOV 0 4 2024 QAeuA -51 5 Planning Services Department 200 S. Main Street • Grapevine, TX 76051 • 817.410.3155 • htt s:/p /bit.ly/GranevinePlannina Updated June 21, 2024 ORDINANCE NO. 2025-003 AN ORDINANCE OF THE CITY COUNCIL OF THE CITY OF GRAPEVINE, TEXAS, ISSUING CONDITIONAL USE PERMIT CU24-51 TO AMEND THE PREVIOUSLY APPROVED SITE PLAN CU24-01 (ORDINANCE NO. 2024-044) FOR A PLANNED COMMERCIAL CENTER IN EXCESS OF 1,000,000 SQUARE FEET OF GROSS LEASABLE SPACE, SPECIFICALLY TO ADD THREE PUBLIC USE, FREESTANDING LEVEL 3 ELECTRIC VEHICLE (EV) CHARGING STATIONS TO THE EXISTING MALL PARKING LOT FOR BLOCK 1, LOT 1R3, GRAPEVINE MILLS ADDITION, PHASE 1 (3000 GRAPEVINE MILLS PARKWAY), IN A DISTRICT ZONED "CC", COMMUNITY COMMERCIAL DISTRICT ALL IN ACCORDANCE WITH A SITE PLAN APPROVED PURSUANT TO SECTION 47 OF ORDINANCE NO.82-73 AND ALL OTHER CONDITIONS, RESTRICTIONS AND SAFEGUARDS IMPOSED HEREIN; CORRECTING THE OFFICIAL ZONING MAP; PRESERVING ALL OTHER PORTIONS OF THE ZONING ORDINANCE; PROVIDING A CLAUSE RELATING TO SEVERABILITY; DETERMINING THAT THE PUBLIC INTERESTS, MORALS AND GENERAL WELFARE DEMAND THE ISSUANCE OF THIS CONDITIONAL USE PERMIT; PROVIDING A PENALTY NOT TO EXCEED THE SUM OF TWO THOUSAND DOLLARS ($2,000.00); DECLARING AN EMERGENCY AND PROVIDING AN EFFECTIVE DATE WHEREAS, an application was made requesting issuance of a conditional use permit by making applications for same with the Planning and Zoning Commission of the City of Grapevine, Texas, as required by State statutes and the zoning ordinance of the City of Grapevine, Texas, and all the legal requirements, conditions and prerequisites having been complied with, the case having come before the City Council of the City of Grapevine, Texas, after all legal notices requirements, conditions and prerequisites having been complied with; and WHEREAS, the City Council of the City of Grapevine, Texas, at a public hearing called by the City Council did consider the following factors in making a determination as to whether this requested conditional use permit should be granted or denied: safety of the motoring public and the pedestrians using the facilities in the area immediately surrounding the site; safety from fire hazards and measures for fire control; protection of adjacent property from flood or water damages, noise producing elements, and glare of the vehicular and stationary lights and effect of such lights on established character of the neighborhood; location, lighting, and types of signs and relation of signs to traffic control and adjacent property, street size and adequacy of width for traffic reasonably expected to be generated by the proposed use around the site and in the immediate neighborhood; adequacy of parking as determined by requirements of this ordinance for off-street parking facilities; location of ingress and egress points for parking and off-street locating spaces, and protection of public health by surfacing on all parking areas to control dust; effect on the promotion of health and the general welfare; effect on light and air; the effect on the overcrowding of the land; the effect on the concentration of population; the effect on the transportation, water, sewerage, schools, parks and other facilities; and WHEREAS, the City Council of the City of Grapevine, Texas, at a public hearing called by the City Council of the City of Grapevine, Texas, did consider the following factors in making a determination as to whether this requested conditional use permit should be granted or denied; effect on the congestion of the streets, the fire hazards, panics and other dangers possibly present in the securing of safety from same, the effect on the promotion of health and the general welfare, effect on adequate light and air, the effect on the overcrowding of the land, the effect on the concentration of population, the effect on the transportation, water, sewerage, schools, parks and other public facilities; and WHEREAS, all of the requirements of Section 48 of Ordinance No. 82-73 have been satisfied by the submission of evidence at a public hearing; and WHEREAS, the City Council further considered among other things the character of the existing zoning district and its peculiar suitability for particular uses and with the view to conserve the value of buildings and encourage the most appropriate use of land throughout this City; and WHEREAS, the City Council of the City of Grapevine, Texas, does find that there is a public necessity for the granting of this conditional use permit, that the public demands it, that the public interest clearly requires the amendment, that the zoning changes do not unreasonably invade the rights of those who bought or improved property with reference to the classification which existed at the time their original investment was made; and WHEREAS, the City Council of the City of Grapevine, Texas, does find that the conditional use permit lessens the congestion in the streets, helps secure safety from fire, panic and other dangers, prevents the overcrowding of land, avoids undue concentration of population, facilitates the adequate provisions of transportation, water, sewerage, schools, parks and other public requirements; and WHEREAS, the City Council of the City of Grapevine, Texas, has determined that there is a necessity and need for this conditional use permit and has also found and determined that there has been a change in the conditions of the property surrounding and in close proximity to the property requested for a change since this property was originally classified and, therefore, feels that the issuance of this conditional use permit for the particular piece of property is needed, is called for, and is in the best interest of the public Ordinance No. 2025-003 2 at large, the citizens of the City of Grapevine, Texas, and helps promote the general health, safety and welfare of this community. NOW, THEREFORE, BE IT ORDAINED BY THE CITY COUNCIL OF THE CITY OF GRAPEVINE, TEXAS: Section 1. That the City does hereby issue a conditional use permit in accordance with Section 48 of Ordinance No. 82-73, the Comprehensive Zoning Ordinance of the City of Grapevine, Texas, same being also known as Appendix "D" of the City Code, by granting conditional use permit CU24-51 to amend the previously approved site plan of CU24-01 (Ordinance No. 2024-044) for a planned commercial center in excess of 1,000,000 square feet of gross leasable space, specifically to add three public use, freestanding Level 3 electric vehicle charging stations (Electrify America) to the existing mall parking lot in a district zoned "CC", Community Commercial District within the following described property: Block 1, Lot 1 R3, Grapevine Mills Addition, Phase 1 (3000 Grapevine Mills Parkway) all in accordance with a site plan approved pursuant to Section 47 of Ordinance No. 82-73, attached hereto and made a part hereof as Exhibit "A", and all other conditions, restrictions, and safeguards imposed herein, including but not limited to the following: None. Section 2. The City Manager is hereby directed to amend the official zoning map of the City of Grapevine, Texas, to reflect the herein conditional use permit. Section 3. That in all other respects the use of the tract or tracts of land herein above described shall be subject to all the applicable regulations contained in said City of Grapevine zoning ordinance and all other applicable and pertinent ordinances of the City of Grapevine, Texas. Section 4. That the zoning regulations and districts as herein established have been made in accordance with the comprehensive plan for the purpose of promoting health, safety, morals and the general welfare of the community. They have been designed with respect to both present conditions and the conditions reasonably anticipated to exist in the foreseeable future; to lessen congestion in the streets, to secure safely from fire, panic, flood and other dangers; provide adequate light and air; to prevent overcrowding of land, to avoid undue concentration of population; facilitate the adequate provisions of transportation, water, sewerage, drainage and surface water, parks and other public requirements, and to make adequate provisions for the normal business, commercial needs and development of the community. They have been made with reasonable consideration, among other things, of the character of the district, and its peculiar suitability for the particular uses and with a view of conserving the value of buildings and encouraging the most appropriate use of land throughout the community. Section 5. This ordinance shall be cumulative of all other ordinances of the City of Grapevine, Texas, affecting zoning and shall not repeal any of the provisions of said Ordinance No. 2025-003 3 ordinances except in those instances where provisions of those ordinances which are in direct conflict with the provisions of this ordinance. Section 6. That the terms and provisions of this ordinance shall be deemed to be severable and that if the validity of the zoning affecting any portion of the tract or tracts of land described herein shall be declared to be invalid, the same shall not affect the validity of the zoning of the balance of the tract or tracts of land described herein. Section 7. Any person violating any of the provisions of this ordinance shall be deemed guilty of a misdemeanor and upon conviction thereof shall be fined in a sum not to exceed Two Thousand Dollars ($2,000.00) and a separate offense shall be deemed committed upon each day during or on which a violation occurs or continues. Section 8. The fact that the present ordinances and regulations of the City of Grapevine, Texas, are inadequate to properly safeguard the health, safety, morals, peace and general welfare of the inhabitants of the City of Grapevine, Texas, creates an emergency for the immediate preservation of the public business, property, health, safety and general welfare of the public which requires that this ordinance shall become effective from and after the date of its final passage, and it is accordingly so ordained. PASSED AND APPROVED BY THE CITY COUNCIL OF THE CITY OF GRAPEVINE, TEXAS on this the 21st day of January, 2025. APPROVED: William D. Tate Mayor ATTEST: Tara Brooks City Secretary APPROVED AS TO FORM: Matthew C.G. Boyle City Attorney Ordinance No. 2025-003 4 TX220234 GRAPEVINE SIMON GRAPEVINE MILLS 3000 GRAPEVINE MILLS PARKWAY GRAPEVINE, TX 76051 REV DESCRIPTIONDATE CHECKED BY: DRAWN BY: PROJECT NO: IT IS A VIOLATION OF LAW FOR ANY PERSON, UNLESS THEY ARE ACTING UNDER THE DIRECTION OF A LICENSED PROFESSIONAL ENGINEER, TO ALTER THIS DOCUMENT. SHEET NUMBER SHEET TITLE R BLACK & VEATCH 11401 LAMAR AVENUE OVERLAND PARK, KS 66211 (913) 458-2000 ELECTRIFY AMERICA, LLC. 1950 OPPORTUNITY WAY SUITE 1500 RESTON, VA 20190 0 07/10/24 ISSUED FOR CONSTRUCTION NMB GAK 411370 1 09/24/24 REISSUED FOR CONSTRUCTION PURPOSE STATEMENT THE PURPOSE OF CONDITIONAL USE CU24-51 IS TO AMEND THE PREVIOUSLY APPROVED SITE PLAN CU24-01 (ORD. 2024-044) FOR A PLANNED COMMERCIAL CENTER IN EXCESS OF 1,000,000 SQUARE FEET OF GROSS, LEASABLE SPACES. THIS REQUEST IS SPECIFICALLY TO ADD THREE LEVEL 3 ELECTRIC VEHICLE (EV) CHARGING STATIONS TO THE SITE FOR PUBLIC USE. 2 12/09/24 CITY COMMENTS H. SUGGS SURVEY, A-1415 J. GIBSON SURVEY, A-586 3 01/07/25 CITY COMMENTS CASE NAME: GRAPEVINE MILLS MALL EV CASE NUMBER: CU24-51 LOCATION: 3000 GRAPEVINE MILLS PARKWAY BLOCK 1, LOT 1R3, GRAPEVINE MILLS ADDITION 3 TITLE SHEET & PROJECT DATA T-1 SIMON GRAPEVINE MILLS 3000 GRAPEVINE MILLS PARKWAY GRAPEVINE, TX 76051 3TITLE SHEET & PROJECT DATA DIMENSIONAL CONTROL SITE PLANC-1 E-1 T-1 THIS SITE IS LOCATED IN FLOOD ZONE "X". AREA DETERMINED TO BE OUTSIDE OF THE 0.2% ANNUAL CHANCE FLOOD PLAIN. PERMITTING JURISDICTION: GRAPEVINE, TX ZONING CLASS:CC - COMMUNITY COMMERCIAL DISTRICT SITE SITE ONCOR ELECTRIC DELIVERY CO POWER COMPANY: EQUIPMENT SUPPLIER: COUNTY: TARRANT LATITUDE (NAD83): 32° 58' 02.676" N 32.96741° LONGITUDE (NAD83): 97° 02' 24.169" W -97.040047° SIMON MALLS PROPERTY OWNER: CONTACT ENGINEER: ELECTRIFY AMERICA, LLC. 1950 OPPORTUNITY WAY SUITE 1500 RESTON, VA 20190 RUSSELL POLLOM (913) 458-6274 POLLOMRE@BV.COM LOCATION MAPAREA MAP PROJECT DESCRIPTIONSITE INFORMATION CONTRACTOR NOTE CONTRACTOR SHALL COMPLETE INSTALL PER THE SIGNED AND THE SEALED SET OF DRAWINGS. ANY NECESSARY DEVIATIONS FROM THE DRAWINGS MUST BE SUBMITTED THROUGH AN RFI REQUEST PROCESS WITH ENGINEERING FOR AN APPROVAL PRIOR TO CONTRACTOR PROCEEDING WITH A DEVIATION OF THE SIGNED AND SEALED SET OF DRAWINGS. CALL BEFORE YOU DIG ENGINEER OF RECORD SHEET NO: DRAWING INDEX SHEET TITLE REV NO: DO NOT SCALE DRAWINGS ZONING INFORMATION FLOOD HAZARD AREA NOTE APPLICABLE CODES FOR REFERENCE ONLY DRAWINGS CONTRACTOR SHALL VERIFY ALL PLANS, EXISTING DIMENSIONS & CONDITIONS ON THE JOB SITE & SHALL IMMEDIATELY NOTIFY THE ENGINEER IN WRITING OF ANY DISCREPANCIES BEFORE PROCEEDING WITH THE WORK. 11"x17" PLOT WILL BE HALF SCALE UNLESS NOTED TX220234 GRAPEVINE INSTALLATION OF ELECTRIC VEHICLE CHARGING EQUIPMENT UTILITY PLAN E-3 FOCUSED SITE PLAN C-2 ELECTRICAL DETAILS GROUNDING DETAILSG-1 E-2 SINGLE LINE DIAGRAM 3000 GRAPEVINE MILLS PARKWAY GRAPEVINE, TX 76051 EV SITE ADDRESS: SITE ELEVATION C-3 EQUIPMENT DETAILS C-4 D-1 DEMOLITION SITE PLAN D-2 ·INSTALL (1) UTILITY TRANSFORMER ·INSTALL (1) UTILITY METER ·INSTALL (1) SWITCHBOARD ASSEMBLY ·INSTALL (3) 360KW BTC POWER UNIT ·INSTALL (6) 350KW BTC DISPENSERS ·INSTALL (1) LIGHT POLE C-5 GENERAL NOTES 1GN-1 GENERAL NOTES 2GN-2 GENERAL NOTES 3GN-3 ENLARGED EQUIPMENT LAYOUT ELECTRICAL PLAN E-5 3 3 3 3 C-6 EQUIPMENT DETAILSD-3 ELECTRICAL DETAILSE-4 UNDERGROUND SERVICE ALERT UTILITY NOTIFICATION CENTER OF TEXAS 811 OR 1-800-669-8344 3 WORKING DAYS UTILITY NOTIFICATION PRIOR TO CONSTRUCTION ALL WORK SHALL COMPLY WITH THE FOLLOWING APPLICABLE CODES: 2021 INTERNATIONAL BUILDING CODE 2021 INTERNATIONAL FIRE CODE 2021 INTERNATIONAL PLUMBING CODE 2021 INTERNATIONAL MECHANICAL CODE 2020 NATIONAL ELECTRICAL CODE IN THE EVENT OF CONFLICT, THE MOST RESTRICTIVE CODE SHALL PREVAIL PROPERTY SURVEY STAGING PLAN HENEIN, MAGED PE # 102109 BLACK & VEATCH CORPORATION STRIPING PLAN C-7 APN: 41-307-097 ACCESSIBILITY DETAILS EQUIPMENT DETAILS EQUIPMENT DETAILSD-4 SITE PLANC-0 3 SITE PLANC-0.1 32 2 3 3 3 3 3 3 3 3 3 3 3 3 3 3 3 3 2 3 SITE PLAN FOR GRAPEVINE MILLS MALL EV LOT X-Y, BLOCK X, SUBDIVISION NAME GRAPEVINE MILLS ADDITION BLOCK 1 LOT 1R3 H. SUGGS SURVEY, A-1415 J. GIBSON SURVEY, A-586 CITY OF GRAPEVINE, TARRANT COUNTY, TEXAS 1.0989 AC OR 47,869 SF ZONE: “CC” COMMUNITY COMMERCIAL DISTRICT DATE OF PREPARATION: DECEMBER 6, 2024 CASE NAME: GRAPEVINE MILLS MALL EV CASE NUMBER: CU24-51 LOCATION: 3000 GRAPEVINE MILLS PARKWAY BLOCK 1, LOT 1R3, GRAPEVINE MILLS ADDITION MAYOR SECRETARY DATE: PLANNING AND ZONING COMMISSION DATE: SHEET:OF APPROVAL DOES NOT AUTHORIZE ANY WORK IN CONFLICT AITH ANY CODES OR ORDINANCES. PLANNING SERVICES DEPARTMENT 1 2 2 MAGED HENEIN 102109 01/07/2025 8 S COCO E G EECOCO E S G S FRONT 541 541 542 541 541 542 541 540 542 54 2 543 542 543 54 2 542 SITE PLAN TX220234 GRAPEVINE SIMON GRAPEVINE MILLS 3000 GRAPEVINE MILLS PARKWAY GRAPEVINE, TX 76051 REV DESCRIPTIONDATE CHECKED BY: DRAWN BY: PROJECT NO: IT IS A VIOLATION OF LAW FOR ANY PERSON, UNLESS THEY ARE ACTING UNDER THE DIRECTION OF A LICENSED PROFESSIONAL ENGINEER, TO ALTER THIS DOCUMENT. SHEET NUMBER SHEET TITLE R BLACK & VEATCH 11401 LAMAR AVENUE OVERLAND PARK, KS 66211 (913) 458-2000 ELECTRIFY AMERICA, LLC. 1950 OPPORTUNITY WAY SUITE 1500 RESTON, VA 20190 0 07/10/24 ISSUED FOR CONSTRUCTION NMB GAK 411370 1 09/24/24 REISSUED FOR CONSTRUCTION PURPOSE STATEMENT THE PURPOSE OF CONDITIONAL USE CU24-51 IS TO AMEND THE PREVIOUSLY APPROVED SITE PLAN CU24-01 (ORD. 2024-044) FOR A PLANNED COMMERCIAL CENTER IN EXCESS OF 1,000,000 SQUARE FEET OF GROSS, LEASABLE SPACES. THIS REQUEST IS SPECIFICALLY TO ADD THREE LEVEL 3 ELECTRIC VEHICLE (EV) CHARGING STATIONS TO THE SITE FOR PUBLIC USE. 2 12/09/24 CITY COMMENTS H. SUGGS SURVEY, A-1415 J. GIBSON SURVEY, A-586 3 01/07/25 CITY COMMENTS CASE NAME: GRAPEVINE MILLS MALL EV CASE NUMBER: CU24-51 LOCATION: 3000 GRAPEVINE MILLS PARKWAY BLOCK 1, LOT 1R3, GRAPEVINE MILLS ADDITION 3 SITE PLAN C-0200' 100' 0 200'400' 1"=200' EXISTING TREE (TYP) EXISTING PARKING LINE (TYP) EXISTING PROPERTY LINE (TYP) SEE DIMENSIONAL CONTROL SITE PLAN SHEET C-1 EXISTING DRAIN INLET (TYP) EXISTING BUILDING (TYP) GRAPEVINE MILLS CIR E W GRAPEVINE MILLS CIR GRAP E V I N E M I L L S GR A P E V I N E M I L L S B L V D N GRAP E V I N E M I L L S C I R C L E E STAR S A N D STRIP E S W A Y FM 2 4 9 9 GR A P E V I N E M I L L S P A R K W A Y STA T E H W Y 1 2 1 STA T E H W Y 2 6 ANDERSON GIBSON GR A P E V I N E M I L L S C I R E 1. REFUSE DISPOSAL AREAS SHALL BE LANDSCAPED AND SCREENED FROM VIEW IN ACCORDANCE WITH THE ZONING ORDINANCE. 2. MECHANICAL AND ELECTRICAL EQUIPMENT INCLUDING AIR CONDITIONING UNITS, SHALL BE DESIGNED, INSTALLED, AND OPERATED TO MINIMIZE NOISE IMPACT ON SURROUNDING PROPERTY, ALL SUCH EQUIPMENT SHALL BE SCREENED FROM PUBLIC VIEW IN ACCORDANCE WITH THE ZONING ORDINANCE. 3. OPEN STORAGE, WHERE PERMITTED, SHALL BE SCREENED IN ACCORDANCE WITH THE ZONING ORDINANCE. 4. THE MASONRY REQUIREMENTS OF SECTION 54 OF THE ZONING ORDINANCE SHALL BE MET. 5. ILLUMINATED SIGNAGE WAS INCLUDED IN THE DETERMINATION OF THE SITE ILLUMINATION LEVELS. 6. OUTDOOR LIGHTING SHALL COMPLY WITH ILLUMINATION STANDARDS WITHIN SECTION 55 OF THE ZONING ORDINANCE UNLESS SPECIFICALLY EXCEPTED. 7. PROPOSED GROUND SIGNAGE SHALL MEET THE MINIMUM REQUIREMENTS OF SECTION 60 OF THE ZONING ORDINANCE AND IS CONTINGENT UPON APPROVAL OF A SEPARATE BUILDING PERMIT WITH BUILDING SERVICES. 8. ALL ONSITE ELECTRICAL CONDUCTORS ASSOCIATED WITH NEW CONSTRUCTION SHALL BE LOCATED UNDERGROUND. 9. USES SHALL CONFORM IN OPERATION, LOCATION, AND CONSTRUCTION TO THE FOLLOWING PERFORMANCE STANDARDS IN SECTION 55 OF THE ZONING ORDINANCE: NOISE, SMOKE AND PARTICULATE MATTER, ODOROUS MATTER, FIRE OR EXPLOSIVE HAZARD MATERIAL, TOXIC AND NOXIOUS MATTER, VIBRATION, AND/OR OTHER PERFORMANCE STANDARDS. 10. ALL REQUIREMENTS OF THE CITY OF GRAPEVINE SOIL EROSION CONTROL ORDINANCE SHALL BE MET DURING THE PERIOD OF CONSTRUCTION. CITY OF GRAPEVINE NOTES BURLIN G T O N M A R S H A L L S TH E CH I L D R E N ' S PL A C E LE G O L A N D SE A L I F E AM C H& M OLD N A V Y ARHA U S ME O W WO L F FIELDHOUSE USA NE I M A N MA R C U S OFF5 T H ROS S SUN & S K I SPORT S ROUND ONE NIKE OFF B R O A D W A Y G R A P E V I N E M I L L S C I R C L E W GR A P E V I N E M I L L S C I R E SITE LOCATION MAP NOT TO SCALE SITE PLAN FOR GRAPEVINE MILLS MALL EV LOT X-Y, BLOCK X, SUBDIVISION NAME GRAPEVINE MILLS ADDITION BLOCK 1 LOT 1R3 H. SUGGS SURVEY, A-1415 J. GIBSON SURVEY, A-586 CITY OF GRAPEVINE, TARRANT COUNTY, TEXAS 1.0989 AC OR 47,869 SF ZONE: “CC” COMMUNITY COMMERCIAL DISTRICT DATE OF PREPARATION: DECEMBER 6, 2024 CASE NAME: GRAPEVINE MILLS MALL EV CASE NUMBER: CU24-51 LOCATION: 3000 GRAPEVINE MILLS PARKWAY BLOCK 1, LOT 1R3, GRAPEVINE MILLS ADDITION MAYOR SECRETARY DATE: PLANNING AND ZONING COMMISSION DATE: SHEET:OF APPROVAL DOES NOT AUTHORIZE ANY WORK IN CONFLICT AITH ANY CODES OR ORDINANCES. PLANNING SERVICES DEPARTMENT SITE 2 MACY ' SBACK S T A G E 282'-7 " 74 3 ' - 4 " RA I N F O R E S T CA F E AMERI C A N FREIG H T ROOMS TO GO VARIOUS CHUCK E. CHEESE UNOCCUPIED DENNY'S FORMER PAPA'S CRAB FORMER DAYLIGHT GOLF BLUEGOOSE DISCOUNT TIREVINE MEDICAL CENTERCENTRUM URGENT CARE CHICK-FIL-A CHIPOTLE APPLEBEE'S POLLO REGIO SPRINGHILL SUITES HYATT PLACE HOMEWOOD SUITES 2 2 MAGED HENEIN 102109   TX220234 GRAPEVINE SIMON GRAPEVINE MILLS 3000 GRAPEVINE MILLS PARKWAY GRAPEVINE, TX 76051 REV DESCRIPTIONDATE CHECKED BY: DRAWN BY: PROJECT NO: IT IS A VIOLATION OF LAW FOR ANY PERSON, UNLESS THEY ARE ACTING UNDER THE DIRECTION OF A LICENSED PROFESSIONAL ENGINEER, TO ALTER THIS DOCUMENT. SHEET NUMBER SHEET TITLE R BLACK & VEATCH 11401 LAMAR AVENUE OVERLAND PARK, KS 66211 (913) 458-2000 ELECTRIFY AMERICA, LLC. 1950 OPPORTUNITY WAY SUITE 1500 RESTON, VA 20190 0 07/10/24 ISSUED FOR CONSTRUCTION NMB GAK 411370 1 09/24/24 REISSUED FOR CONSTRUCTION PURPOSE STATEMENT THE PURPOSE OF CONDITIONAL USE CU24-51 IS TO AMEND THE PREVIOUSLY APPROVED SITE PLAN CU24-01 (ORD. 2024-044) FOR A PLANNED COMMERCIAL CENTER IN EXCESS OF 1,000,000 SQUARE FEET OF GROSS, LEASABLE SPACES. THIS REQUEST IS SPECIFICALLY TO ADD THREE LEVEL 3 ELECTRIC VEHICLE (EV) CHARGING STATIONS TO THE SITE FOR PUBLIC USE. 2 12/09/24 CITY COMMENTS H. SUGGS SURVEY, A-1415 J. GIBSON SURVEY, A-586 3 01/07/25 CITY COMMENTS CASE NAME: GRAPEVINE MILLS MALL EV CASE NUMBER: CU24-51 LOCATION: 3000 GRAPEVINE MILLS PARKWAY BLOCK 1, LOT 1R3, GRAPEVINE MILLS ADDITION 3 SITE PLAN C-0.1 ZONING HISTORY CU95-36 (ORD. NO. 9608) - ESTABLISH A PLANNED COMMERCIAL CENTER OVER 1,000,000 SQUARE FEET OF GROSS LEASABLE AREA. ADDENDUM 96-01 (PRESOLUTION NO 95-34) - APPROVAL OF (8) PUBLIC ENTRYWAY ELEVATIONS FOR GRAPEVINE MILLS MALL. ADDENDUM 95-26 (ORD. NO. 96-79) - AMEND SITE LAYOUT. CU97-05 (ORD. NO. 97-09) - CONDITIONAL USE REQUEST (SEGA GAMEWORKS) FOR ALCOHOLIC BEVERAGE SALES TO INCLUDE BEER, WINE AND MIXED BEVERAGES. SU97-09 (ORD. NO. 97-10) - SPECIAL USE REQUEST SKILL ORIENTED GAMES IN EXCESS OF EIGHT MACHNES AND TWO BILLIARD TABLES. ADDENDUM 97-06 (ORD. NO 97-11) - AMEND THE SITE LAYOUT (AMC THEATER). CU97-13 (ORD. NO. 97-25) - CONDITIONAL USE REQUEST (THE AMERICAN WILDERNESS EXPERIENCE) FOR ALCOHOLIC BEVERAGES TO INCLUDE BEER, WINE AND MIXED BEVERAGES. CU97-18 (ORD. NO. 97-40) - CONDITIONAL USE REQUEST (RAINFOREST CAFE) FOR ALCOHOLIC BEVERAGES TO INCLUDE BEER, WINE AND MIXED BEVERAGES. CU97-25 (ORD. NO. 97-25) - CONDITIONAL USE REQUEST (TRES HOMBRES) FOR ALCOHOLIC BEVERAGES TO INCLUDE BEER, WINE AND MIXED BEVERAGES. CU97-29 (ORD. NO. 97-56) - CONDITIONAL USE REQUEST FOR MALL SIGNAGE AND AN 80 FOOT ENTERTAINMENT GLOBE (ORD. NO. 97-61). CU97-36 (ORD. NO. 97-72) - AMEND THE SITE LAYOUT (MICHAELS). CU97-39 (ORD. NO. 97-99) - CONDITIONAL USE REQUEST TO AMEND THE LANDSCAPING PLAN AND PROVIDE THREE 50 FOOT, AND TWO FOOT OUT-PARCEL SIGNS. CU97-40 (ORD. NO. 97-90) - CONDITIONAL USE REQUEST (CHILI'S TOO) FOR ALCOHOLIC BEVERAGES TO INCLUDE BEER, WINE AND MIXED BEVERAGES. CU97-41 (ORD. NO. 97-91) - CONDITIONAL USE REQUEST (DICK CLARK'S RESTAURANTS) FOR ALCOHOLIC BEVERAGES TO INCLUDE BEER, WINE AND MIXED BEVERAGES. CU97-42 (ORD. NO. 97-92) - AMEND THE SITE LAYOUT (DISCOUNT TIRE). CU97-82 (ORD. NO. 97-128) - CONDITIONAL USE REQUEST (ROOMS TO GO) TO AMEND THE SITE LAYOUT (PHASE 1). CU97-83 (ORD. NO. 97-129) - CONDITIONAL USE REQUEST (CHICK-FIL-A) TO AMEND THE SITE LAYOUT (PHASE 1). CU97-84 (ORD. NO. 97-130 - CONDITIONAL USE REQUEST (BAXTERS AFICIONADO COLLECTIONS) FOROFF-PREMISES CONSUMPTION OF ALCOHOLIC BEVERAGE (WINE ONLY, PHASE 1). CU97-65 (ORD. NO. 97-147) - CONDITIONAL USE REQUEST (PRIMACARE) TO AMEND THE SITE LAYOUT (PHASE 1). CU97-75 (ORD. NO. 96-10) - AMEND THE MALL SIGNAGE PLAN FOR OUT-PARCEL TENANT WALL SIGNS (PHASE 1). CU97-76 (ORD. NO. 96-11) - CONDITIONAL USE REQUEST (COZYMEL'S) TO AMEND THE SITE LAYOUT (PHASE 1). CU97-77 (ORD. NO. 96-12) - AMEND THE FLOOR PLAN FOR ALCOHOL BEVERAGE SALES AT SEGA GAMEWORKS (PHASE 1). CU98-03 (ORD. NO. 96-12) - AMEND THE FLOOR PLAN FOR ALCOHOL BEVERAGE SALES AT DICK CLARK'S RESTAURANTS (PHASE 1). CU98-07 (ORD. NO. 96-40) - AMEN DTHE FLOOR PLAN FOR ALCOHOL BEVERAGE SALES AT CORNER BAKERY R-1 (PHASE 1). CU98-03 (ORD. NO. 96-12) - AMEND THE FLOOR PLAN FOR ALCOHOL BEVERAGE SALES AT AMERICAN WILDERNESS (PHASE 1). CU98-47 (ORD. NO. 96-118) - AMEND THE FLOOR PLAN AT COZYMEL'S (PHASE 1). CU98-48 (ORD. NO. 97-90) - CONDITIONAL USE REQUEST (MASON JAR/ MJ'S CHOP HOUSE) FOR ALCOHOLIC BEVERAGE SALES TO INCLUDE BEER, WINE AND MIXED BEVERAGES (PHASE 1). CU98-48 (ORD. NO. 97-90) - AMEND THE SITE LAYOUT PLAN (AMC THEATER) TO INCLUDE A CANOPY ADJACENT TO THE EXISTING TICKET BOOTHS (PHASE 1). CU98-57 (ORD. NO. 97-130) - CONDITIONAL USE REQUEST (BLACK-EYED PEAS) FOR ALCOHOLIC BEVERAGE SALES TO INCLUDE BEER, WINE AND MIXED BEVERAGES (PHASE 1). SITE DATA TABLE LOT SIZE LOT SIZE SF BUILDING COVERAGE DENSITY % BUILDING HEIGHT PAVED AREA SF OPEN SPACE SF - (%) TOTAL BLDG, PATIO & PAVED AREA SF PARKING REQUIRED PARKING PROVIDED APPLEBEE'S - LOT 3, BLOCK 5 62,485 7,189 11.51 22'-8" 39,870 15,405- (24.66)47,060 79 101 CENTRUM FORMERLY CARENOW - LOT 2, BLOCK 4 23,598 3,855 18.30 25'-0" 13,014 6,729 - (28.50)18,889 25 25 CHICK-FIL-A - LOT 1, BLOCK 5 53,768 3,882 7.11 25'-0"31,337 18,810-(34.8)35,159 37 47 CHIPOTLE MEXICAN GRILL - LOT 2, BLOCK 5 38,898 3,457 8.89 24'-0" 21,977 13,144-(33.80)25,754 29 42 CHUCK E. CHEESE'S - LOT 5, BLOCK 2 88,601 6,600 13.51 20'-2' 62,274 14,358-(16.21)74,223 146 147 DENNY'S - LOT 3, BLOCK 2 77,755 8,429 12.10 30'-0" 49,481 14,045-(24.50)58,690 126 126 DISCOUNT TIRE - LOT 1, BLOCK 4 37,346 7,700 20.62 50'-0" 20,170 9,478-(24.40)57,570 19 27 VACANT FORMERLY PAPA’S CRAB - LOT 4, BLOCK 2 85,135 10,345 12.15 77'-0" 58,413 15,275-(17.90)69,858 126 147 GRAPEVINE MILLS MALL - LOT 1R3 5,746,673 1,868,952 5,363,842 7489 8462 HOMEWOOD SUITES - LOT 2, BLOCK 6 119,608 14,603 14.01 69'-8" 45,101 46,772-(39.19)68,063 128 128 HYATT PLACE - LOT 1,BLOCK 6 108,488 5,903 11.01 21'-11"58,322 36,615-(33.80)71,873 126 130 VINE MEDICAL CENTER FORMERLY FED-EX/ KINKOS - LOT 4, BLOCK 4 47,899 3,880 7.08 64'-1" 20,522 25,571 - (53.38)27,122 42 38 VACANT FORMERLY DAYLIGHT GOLF - LOT 1R 104,239 14,604 14.01 31'-0" 67,248 22,387 - (21.48)81,85 176 176 VARIOUS BUSINESSES - LT. A-R1, BK 2 125,191 28,742 24.18 56,104 17,735- (16.00)92,546 139 139 ROOMS TO GO - LOT 2, BLOCK 2 184,171 39,870 21.85 25'-8" 90,000 54,301- (29.50)128,870 205 228 BLUE GOOSE - LOT 3, BLOCK 4 53,676 5,903 11.01 21'-11"33,071 12,054 - (22.50)38,980 66 88 SPRINGHILL SUITES - TRACT AR 101,243 22,962 19.24 51,287 33,085 - (32.68)68,159 114 114 POLLO REGIO - LOT 4, BLOCK 5 54,791 16,872 16.66 33,827 17,084 - (31.18)37,707 45 54 TRACT B ADJACENT TO HOMEWOOD 99,252 TOTAL 7,212,817 2,073,689 6,366,217 9117 10219 2 SITE DATA TABLE WAS PREPARED USING DATA LISTED ON THE MASTER SITE PLAN FOR GRAPEVINE MILLS MALL PREPARED FOR CASE NUMBER: CU22-23 BOSK LANES PROJECT APPROVED 06/09/2022. SITE DATA TABLE WAS UPDATES TO REFLECT THIS PROJECT. 3 3 3 3 3 3 3 3 3 3 2 2 MAGED HENEIN 102109 01/07/2025 SITE PLAN FOR GRAPEVINE MILLS MALL EV LOT X-Y, BLOCK X, SUBDIVISION NAME GRAPEVINE MILLS ADDITION BLOCK 1 LOT 1R3 H. SUGGS SURVEY, A-1415 J. GIBSON SURVEY, A-586 CITY OF GRAPEVINE, TARRANT COUNTY, TEXAS 1.0989 AC OR 47,869 SF ZONE: “CC” COMMUNITY COMMERCIAL DISTRICT DATE OF PREPARATION: DECEMBER 6, 2024 CASE NAME: GRAPEVINE MILLS MALL EV CASE NUMBER: CU24-51 LOCATION: 3000 GRAPEVINE MILLS PARKWAY BLOCK 1, LOT 1R3, GRAPEVINE MILLS ADDITION MAYOR SECRETARY DATE: PLANNING AND ZONING COMMISSION DATE: SHEET:OF APPROVAL DOES NOT AUTHORIZE ANY WORK IN CONFLICT AITH ANY CODES OR ORDINANCES. PLANNING SERVICES DEPARTMENT CU98-59 (ORD. NO. 96-135) - CONDITIONAL USE REQUEST (SEGA GAMEWORKS) FOR ALCOHOLIC BEVERAGE SALES TO INCLUDE BEER, WINE AND MIXED BEVERAGES (PHASE 1). CU98-79 (ORD. NO. 99-17) - CONDITIONAL USE REQUEST (AMERISUITES) FOR A 125 ROOM 8 STORY HOTEL. CU98-78 (ORD. NO. 99-15) - CONDITIONAL USE REQUEST (AMERICAN WILDERNESS) FOR ALCOHOLIC BEVERAGE SALES TO INCLUDE BEER, WINE AND MIXED BEVERAGES (PHASE 1). CU98-79 (ORD. NO. 99-17) - CONDITIONAL USE REQUEST (SEGA GAMEWORKS) FOR THE INSTALLATION OF SALE COUNTER, GAME SOFTWARE SALES DISPLAY AND ONE PAIR OF ADDITIONAL DOORS. CU98-79 (ORD. NO. 99-17) - CONDITIONAL USE REQUEST (IGUANA AMERAMEX) TO AMEND THE SITE LAYOUT. CU99-17 (ORD. NO. 99-51) - CONDITIONAL USE REQUEST (JEKYLL AND HYDE) FOR ALCOHOLIC BEVERAGE SALES TO INCLUDE BEER, WINE AND MIXED BEVERAGES (PHASE 1). CU98-79 (ORD. NO. 99-17) - CONDITIONAL USE REQUEST (COZYMEL'S) TO AMEND THE SITE LAYOUT. CU99-41 (ORD. NO. 99-) - CONDITIONAL USE REQUEST (BENNIGAN'S) FOR ALCOHOLIC BEVERAGE SALES TO INCLUDE BEER, WINE AND MIXED BEVERAGES (PHASE 1). CU09-37 (ORD. NO. 2009-51) - CONDITIONAL USE REQUEST (APPLEBEE'S) FOR ALCOHOLIC BEVERAGE SALES TO INCLUDE BEER, WINE AND MIXED BEVERAGES (PHASE 1). CU 10-25 - CONDITIONAL USE REQUEST FOR SEA LIFE AND LEGOLAND TO ADD SIGNAGE THROUGHOUT THE MALL. CU10-25A - CONDITIONAL USE REQUEST FOR SEA LIFE AND LEGOLAND TO ALLOW FOR A MONUMENT SIGN AT THE NORTHWEST CORNER OF GRAPEVINE MILLS BOULEVARD SOUTH AND STATE HIGHWAY 26. CU 10-32 (ORD. NO. 2011-21) - CONDITIONAL USE REQUEST (APPLEBEE'S) FOR ALCOHOLIC BEVERAGE SALES TO INCLUDE BEER, WINE AND MIXED BEVERAGES (PHASE 1). CU11-08 (ORD. NO. 2011-21) - CONDITIONAL USE REQUEST FOR ON PREMISE ALCOHOLIC BEVERAGE SALES AND CONSUMPTION FOR A WINE TASTING ROOM. CU13-19 (ORD. NO 2014-05) - CONDITIONAL USE REQUEST (CHILI'S TOO) TO REVISE THE FLOOR PLAN. CU 13-35 (ORD. NO. 2014-05) - CONDITIONAL USE REQUEST (LEGOLAND) FOR AN OUTDOOR SPLASH PAD. CU13-13 CONDITIONAL USE REQUEST (CHIPOTLE) FOR USE OF A DRIVE THROUGH AND ALCOHOLIC BEVERAGE SALES TO INCLUDE BEER, WINE AND MIXED BEVERAGES. CU 15-29 CONDITIONAL USE REQUEST (ROUND 1) FOR ALCOHOLIC BEVERAGE SALES TO INCLUDE BEER, WINE AND MIXED BEVERAGES AND SKILL ORIENTED GAMES. CU 15-46 CONDITIONAL USE REQUEST TO REPLACE EXTERIOR AND ON-PREMISE SIGNS TO ALLOW FOR NEW WAYFINDING SIGNS. CU 15-48 CONDITIONAL USE REQUEST TO AMEND THE PREVIOUSLY APPROVED SITE PLAN OF CU05-27 SPRC, CU02-43 (ORD. 2002-79) FOR A PLANNED COMMERCIAL IN EXCESS OF 1,000,000 SQUARE FEET OF GROSS LEASABLE SPACE WITH THE POSSESSION, STORAGE, RETAIL SALES, AND ON-PREMISE CONSUMPTION OF ALCOHOLIC BEVERAGES (BEER, WINE AND MIXED BEVERAGES), SPECIFICALLY TO REVISE BUILDING ELEVATIONS, FLOOR PLAN, ALLOW DINING OUTSIDE AND OUTDOOR SPEAKERS IN CONJUNCTION WITH A RESTAURANT. U20-17 CONDITIONAL USE REQUEST TO AMEND THE PREVIOUSLY APPROVED SITE PLAN OF U10-25A (ORD. 2011-02) FOR A PLANNED COMMERCIAL CENTER IN EXCESS OF 1,000,000 SQUARE FEET OF GROSS LEASABLE SPACE WITH THE POSSESSION, STORAGE, RETAIL SALES, AND ON-PREMISE CONSUMPTION OF ALCOHOLIC BEVERAGES (BEER AND WINE ONLY) IN CONJUNCTION WITH AN EXISTING RESTAURANT. CU22-20 APPROVED TO MODIFY THE BUILDING'S EXTERIOR ELEVATION TO INSTALL A PARAPET-MOUNTED SIGN ABOVE THE EXISTING HEIGHT OF MACY'S BACKSTAGE. CU22-23 APPROVED TO MODIFY THE NORTH AND EAST EXTERIOR ELEVATIONS THAT INCLUDES A MURAL, A NEW TIERED ENTRY FEATURE, AND ENHANCEMENTS TO THE BUILDING'S FACADE. 83 S S FRON T OVERALL SITE PLAN TX220234 GRAPEVINE SIMON GRAPEVINE MILLS 3000 GRAPEVINE MILLS PARKWAY GRAPEVINE, TX 76051 REV DESCRIPTIONDATE CHECKED BY: DRAWN BY: PROJECT NO: IT IS A VIOLATION OF LAW FOR ANY PERSON, UNLESS THEY ARE ACTING UNDER THE DIRECTION OF A LICENSED PROFESSIONAL ENGINEER, TO ALTER THIS DOCUMENT. SHEET NUMBER SHEET TITLE R BLACK & VEATCH 11401 LAMAR AVENUE OVERLAND PARK, KS 66211 (913) 458-2000 ELECTRIFY AMERICA, LLC. 1950 OPPORTUNITY WAY SUITE 1500 RESTON, VA 20190 0 07/10/24 ISSUED FOR CONSTRUCTION NMB GAK 411370 1 09/24/24 REISSUED FOR CONSTRUCTION PURPOSE STATEMENT THE PURPOSE OF CONDITIONAL USE CU24-51 IS TO AMEND THE PREVIOUSLY APPROVED SITE PLAN CU24-01 (ORD. 2024-044) FOR A PLANNED COMMERCIAL CENTER IN EXCESS OF 1,000,000 SQUARE FEET OF GROSS, LEASABLE SPACES. THIS REQUEST IS SPECIFICALLY TO ADD THREE LEVEL 3 ELECTRIC VEHICLE (EV) CHARGING STATIONS TO THE SITE FOR PUBLIC USE. 2 12/09/24 CITY COMMENTS H. SUGGS SURVEY, A-1415 J. GIBSON SURVEY, A-586 3 01/07/25 CITY COMMENTS CASE NAME: GRAPEVINE MILLS MALL EV CASE NUMBER: CU24-51 LOCATION: 3000 GRAPEVINE MILLS PARKWAY BLOCK 1, LOT 1R3, GRAPEVINE MILLS ADDITION 3 DIMENSIONAL CONTROL SITE PLAN C-120' 10' 0 20'40' 1"=20' EXISTING CLEANOUT (TYP) EXISTING UNDERGROUND MISC LINE (TYP) EXISTING SANITARY MANHOLE (TYP) EXISTING UTILITY SWITCHGEAR SID:3906165-3665935 1. A PERMIT FROM THE BUILDING SERVICES DEPARTMENT IS REQUIRED FOR THE CONSTRUCTION, REPLACEMENT OR INSTALLATION OF AN EV CHARGING STATION IN NON-RESIDENTIAL AND MULTIFAMILY DISTRICTS OR INSTALLATION OF ELECTRICAL EQUIPMENT FOR THE PURPOSES OF CHARGING AN ELECTRIC OR HYBRID VEHICLE IN A RESIDENTIAL DWELLING. 2. EV CHARGING STATIONS MUST BE IN ADDITION TO REQUIRED PARKING SPACES. 3. ALL SIGNAGE ASSOCIATED WITH THE CHARGING STATIONS MUST BE APPROVED AS PART OF THE CONDITIONAL USE PERMIT. 4. NO OFF-PREMISE SIGNAGE, THROUGH INSTALLATION OF CHANGEABLE COPY SCREENS OR DEVICES ARE PERMITTED WITHIN, ON, ADJACENT TO, OR ASSOCIATED WITH AN EV CHARGING STATION. 5. EV CHARGING STATIONS MAY NOT BE LOCATED IMMEDIATELY ADJACENT TO PUBLIC RIGHTS- OF-WAY AND MUST BE LOCATED INTERNAL TO A PROPERTY. 6. IF INSTALLED WITHIN 50 LINEAR FEET OF AN ADJACENT RESIDENTIAL USE OR DISTRICT, SCREENING MUST BE PROVIDED AND CONSISTENT WITH SECTION 50, SUBSECTION B.1., LOCATION OF REQUIRED SCREENING. 7. ALL CHARGING STATIONS MUST BE SETBACK A MINIMUM OF 20 FEET FROM ADJACENT PROPERTY LINES WHEN IMMEDIATELY ADJACENT TO A RESIDENTIAL USE OR DISTRICT. 8. EV SUPPLY EQUIPMENT INCLUDING FEEDERS AND DISTRIBUTION EQUIPMENT SHALL BE PLACED AND OPERATED FROM UNDERGROUND ELECTRIC SOURCES AND NOT FROM ELECTRIC POLES. TRANSFORMERS, SWITCH GEARS, AND OTHER REQUIRED ELECTRICAL COMPONENTS SHALL BE PAD MOUNTED. 9. EVERY APPLICATION AND PERMIT FOR AN EV CHARGING STATION MUST INCLUDE A UTILITY WILL-SERVE LETTER FROM THE LOCAL ELECTRIC DELIVERY COMPANY DETAILING THEIR ABILITY TO SERVE THE SITE. 10. EMERGENCY POWER SHUT-OFF AND PARKING STRUCTURE PROHIBITION REQUIREMENTS SHALL BE REGULATED BY THE BUILDING AND FIRE CODES ADOPTED BY THE CITY. IN ANY CASE WHERE THERE IS CONFLICT BETWEEN ORDINANCE AND CODE, THE MOST RESTRICTIVE REQUIREMENT SHALL APPLY. NOTES 2 2 SEE FOCUSED SITE PLAN SHEET C-3EXISTING FENCE EXISTING PARKING LINE (TYP) EXISTING STORM INLET (TYP) EXISTING LIGHT POLE EXISTING FIRE HYDRANT EXISTING BOLLARD (TYP) EXISTING TREE (TYP) EXISTING SIGN POST (TYP) EXISTING BUILDING EXISTING FIRE LANE STRIPING EXISTING JOB SITE CONEX BOXES EXISTING ASPHALT PARKING LOT (TYP) PROPOSED UTILITY PMH-9 SWITCHGEAR PROPOSED SCREENING FENCE 2 EXIST I N G 2 0 ' - 0 " DRAI N A G E EASE M E N T EX I S T I N G 1 5 ' - 0 " UT I L I T Y EA S E M E N T 2 4 ' - 3 " DR I V E A I S L E 2 5 ' - 0 " DR I V E A I S L E FIE L D H O U S E 2 SITE PLAN FOR GRAPEVINE MILLS MALL EV LOT X-Y, BLOCK X, SUBDIVISION NAME GRAPEVINE MILLS ADDITION BLOCK 1 LOT 1R3 H. SUGGS SURVEY, A-1415 J. GIBSON SURVEY, A-586 CITY OF GRAPEVINE, TARRANT COUNTY, TEXAS 1.0989 AC OR 47,869 SF ZONE: “CC” COMMUNITY COMMERCIAL DISTRICT DATE OF PREPARATION: DECEMBER 6, 2024 CASE NAME: GRAPEVINE MILLS MALL EV CASE NUMBER: CU24-51 LOCATION: 3000 GRAPEVINE MILLS PARKWAY BLOCK 1, LOT 1R3, GRAPEVINE MILLS ADDITION MAYOR SECRETARY DATE: PLANNING AND ZONING COMMISSION DATE: SHEET:OF APPROVAL DOES NOT AUTHORIZE ANY WORK IN CONFLICT AITH ANY CODES OR ORDINANCES. PLANNING SERVICES DEPARTMENT 2 MAGED HENEIN 102109   FRONT 54 1 TX220234 GRAPEVINE SIMON GRAPEVINE MILLS 3000 GRAPEVINE MILLS PARKWAY GRAPEVINE, TX 76051 REV DESCRIPTIONDATE CHECKED BY: DRAWN BY: PROJECT NO: IT IS A VIOLATION OF LAW FOR ANY PERSON, UNLESS THEY ARE ACTING UNDER THE DIRECTION OF A LICENSED PROFESSIONAL ENGINEER, TO ALTER THIS DOCUMENT. SHEET NUMBER SHEET TITLE R BLACK & VEATCH 11401 LAMAR AVENUE OVERLAND PARK, KS 66211 (913) 458-2000 ELECTRIFY AMERICA, LLC. 1950 OPPORTUNITY WAY SUITE 1500 RESTON, VA 20190 0 07/10/24 ISSUED FOR CONSTRUCTION NMB GAK 411370 1 09/24/24 REISSUED FOR CONSTRUCTION PURPOSE STATEMENT THE PURPOSE OF CONDITIONAL USE CU24-51 IS TO AMEND THE PREVIOUSLY APPROVED SITE PLAN CU24-01 (ORD. 2024-044) FOR A PLANNED COMMERCIAL CENTER IN EXCESS OF 1,000,000 SQUARE FEET OF GROSS, LEASABLE SPACES. THIS REQUEST IS SPECIFICALLY TO ADD THREE LEVEL 3 ELECTRIC VEHICLE (EV) CHARGING STATIONS TO THE SITE FOR PUBLIC USE. 2 12/09/24 CITY COMMENTS H. SUGGS SURVEY, A-1415 J. GIBSON SURVEY, A-586 3 01/07/25 CITY COMMENTS CASE NAME: GRAPEVINE MILLS MALL EV CASE NUMBER: CU24-51 LOCATION: 3000 GRAPEVINE MILLS PARKWAY BLOCK 1, LOT 1R3, GRAPEVINE MILLS ADDITION 3 FOCUSED SITE PLAN C-34' 2' 0 4'8' 1/4"=1'-0" FOCUSED PLAN NOTES 1. SOD PLANTED IN THE FALL MUST ESTABLISH ITS ROOTS BEFORE THE FIRST WINTER FROST. DETERMINE WHEN THE FIRST FROST USUALLY OCCURS, AND PLANT THE SOD NO LATER THAN ONE MONTH BEFORE THE FIRST FROST. IF THE CONSTRUCTION IS FINISHED LATER THAN ONE MONTH BEFORE THE FIRST FROST, USE STRAW UNTIL SOD CAN BE INSTALLED. 2. THE CONTRACTOR SHALL RETURN SIDEWALKS, LANDSCAPING, PLANTERS, IRRIGATION SYSTEMS, AND ANY OTHER FACILITIES DISTURBED BY THE WORK TO THE SAME OR BETTER CONDITION THAN EXISTED PRIOR TO THE COMMENCEMENT OF THE WORK. 3. PROPOSED ACCESSIBLE STALL AND ACCESS AISLE SHALL NOT EXCEED 2% MAX SLOPE IN ANY DIRECTION. ACCESS AISLE SHALL BE PAINTED WHITE WITH HATCH LINES SPACED A MAXIMUM OF 36" (INCHES). PROPOSED ACCESSIBLE ROUTE NOT TO EXCEED 5% MAX RUNNING SLOPE AND 2% MAX CROSS SLOPE. PAINTED LETTERING SHALL BE A MINIMUM OF 12 INCHES IN HEIGHT. EXISTING STALL COUNT PROPOSED STALL COUNT PROJECT AREA STALL COUNT HOST APPROVED STALL COUNT 12 6 13 PROPOSED DISPENSER DISPENSER NUMBER 350 KW CABLE TYPE 1*CCS 1*CCS 1*CCS 1*CCS 1*CCS 1*CCS 1A 1B 2A 2B 3A 3B * SHARED 350KW OUTPUT EXISTING PARKING LINE (TYP) EXISTING CONTOUR LINE (TYP)- C-5 PROPOSED RESERVED PARKING FOR ELECTRIC VEHICLE ONLY SIGN (TYP OF 2) B D-3 A D-3 PROPOSED UTILITY TRANSFORMER PROPOSED UTILITY BOLLARD (TYP) SEE ENLARGED PROPOSED EQUIPMENT LAYOUT SHEET C-4 1 2 3 PROPOSED EQUIPMENT PROTECTION BOLLARD (TYP OF 7) B D-2 PROPOSED DISPENSER (TYP OF 6) PROPOSED RESERVED PARKING FOR ELECTRIC VEHICLE ONLY SIGN EXISTING ASPHALT PARKING LOT (TYP) B D-3 A D-3 C D-3 1A 1B 2A 2B 3A 3B - C-5 PROPOSED UTILITY METER MOUNTED ON TRANSFORMER R = 2'-6" L = 3'-11" PROPOSED CONCRETE CURB WITH GUTTER D D-4 EXISTING CONCRETE CURB WITH GUTTER EXISTING TREE (TYP) EXISTING FIRE LANE STRIPING PROPOSED LIGHT POLE WITH CAMERAS (TYP) (CAMERA BY OTHERS) WITH PROPOSED RESERVED PARKING FOR ELECTRIC VEHICLE ONLY SIGN MOUNTED ON LIGHT POLE E D-3 D D-3 B D-1 C D-1 B D-3 PROPOSED 360KW POWER UNIT (TYP OF 3) D D-1 E D-1 CHANGES TO PERVIOUS SURFACE EXISTING PERVIOUS 221 SQ.FT PROPOSED PERVIOUS 488 SQ.FT ELEVATION LEGEND EX. ELEV. EXISTING ELEVATION PR. ELEV. PROPOSED ELEVATION B.C.BASE OF CURB T.C.TOP OF CURB EX. ELEV: 541.20EX. ELEV: 541.13 PR. ELEV: T.C. 541.57 EX. ELEV: B.C. 541.07 PR. ELEV: T.C. 541.53 EX. ELEV: B.C. 541.13 PR. ELEV: T.C. 541.54 EX. ELEV: B.C. 541.14 PR. ELEV: T.C. 541.48 EX. ELEV: B.C. 540.98 EX. ELEV: T.C. 541.80 PROPOSED SCREENING FENCE 2 26'-11" 11'-0"6'-0"4'-2" (TYP OF 3) 10'-6" (TYP OF 5) 18 ' - 0 " 7' - 9 " (T Y P ) 5'-6" 3'-0" 3' - 0 " 1' - 0 " (T Y P ) 10" (TYP) 28'-1" 1' - 0 " (T Y P ) 5' - 0 " 2'-1" 2'-1" (TYP) 5' - 0 " (T Y P ) 15 ' - 0 " 2' - 0 " 5'-0" (TYP) 1'-9" 2 2 2 3 SITE PLAN FOR GRAPEVINE MILLS MALL EV LOT X-Y, BLOCK X, SUBDIVISION NAME GRAPEVINE MILLS ADDITION BLOCK 1 LOT 1R3 H. SUGGS SURVEY, A-1415 J. GIBSON SURVEY, A-586 CITY OF GRAPEVINE, TARRANT COUNTY, TEXAS 1.0989 AC OR 47,869 SF ZONE: “CC” COMMUNITY COMMERCIAL DISTRICT DATE OF PREPARATION: DECEMBER 6, 2024 CASE NAME: GRAPEVINE MILLS MALL EV CASE NUMBER: CU24-51 LOCATION: 3000 GRAPEVINE MILLS PARKWAY BLOCK 1, LOT 1R3, GRAPEVINE MILLS ADDITION MAYOR SECRETARY DATE: PLANNING AND ZONING COMMISSION DATE: SHEET:OF APPROVAL DOES NOT AUTHORIZE ANY WORK IN CONFLICT AITH ANY CODES OR ORDINANCES. PLANNING SERVICES DEPARTMENT B D-1 3 3 3 2 MAGED HENEIN 102109 01/07/2025 851 TX220234 GRAPEVINE SIMON GRAPEVINE MILLS 3000 GRAPEVINE MILLS PARKWAY GRAPEVINE, TX 76051 REV DESCRIPTIONDATE CHECKED BY: DRAWN BY: PROJECT NO: IT IS A VIOLATION OF LAW FOR ANY PERSON, UNLESS THEY ARE ACTING UNDER THE DIRECTION OF A LICENSED PROFESSIONAL ENGINEER, TO ALTER THIS DOCUMENT. SHEET NUMBER SHEET TITLE R BLACK & VEATCH 11401 LAMAR AVENUE OVERLAND PARK, KS 66211 (913) 458-2000 ELECTRIFY AMERICA, LLC. 1950 OPPORTUNITY WAY SUITE 1500 RESTON, VA 20190 0 07/10/24 ISSUED FOR CONSTRUCTION NMB GAK 411370 1 09/24/24 REISSUED FOR CONSTRUCTION PURPOSE STATEMENT THE PURPOSE OF CONDITIONAL USE CU24-51 IS TO AMEND THE PREVIOUSLY APPROVED SITE PLAN CU24-01 (ORD. 2024-044) FOR A PLANNED COMMERCIAL CENTER IN EXCESS OF 1,000,000 SQUARE FEET OF GROSS, LEASABLE SPACES. THIS REQUEST IS SPECIFICALLY TO ADD THREE LEVEL 3 ELECTRIC VEHICLE (EV) CHARGING STATIONS TO THE SITE FOR PUBLIC USE. 2 12/09/24 CITY COMMENTS H. SUGGS SURVEY, A-1415 J. GIBSON SURVEY, A-586 3 01/07/25 CITY COMMENTS CASE NAME: GRAPEVINE MILLS MALL EV CASE NUMBER: CU24-51 LOCATION: 3000 GRAPEVINE MILLS PARKWAY BLOCK 1, LOT 1R3, GRAPEVINE MILLS ADDITION 3 ENLARGED EQUIPMENT LAYOUT C-412" 9" 6" 3" 0 1'2' 1"=1'-0" ENLARGED EQUIPMENT LAYOUT A D-2 PROPOSED SWITCHBOARD ASSEMBLY PROPOSED CONCRETE PAD A D-1 INCOMING 1. CONTRACTOR TO INSTALL KIDDE KEYSAFE PRO S7 OR SIMILAR ON PROPOSED ENCLOSURE OR SWITCHBOARD. PREFERENCE IS ON THE ENCLOSURE IF ONE IS PROPOSED. NOTE: CLEARANCE TABLE EQUIPMENT FRONT BACK SIDES SWITCHGEAR 6'6"6" POWER UNIT 4'SEE DETAIL SEE DETAIL PROPOSED SINGLE GATE (TYP OF 2) PROPOSED FENCE POST (TYP) PROPOSED EQUIPMENT ENCLOSURE A D-4 B D-4 PROPOSED KNOX BOX 1650 WITH SWITCHBOARD KEY (6-1/2"H X 6-1/2"W X 5"D) 2 9'-10" 13 ' - 0 " 1' - 0 " 1'-0"1'-0" (TYP) 1' - 0 " (T Y P ) 23 SITE PLAN FOR GRAPEVINE MILLS MALL EV LOT X-Y, BLOCK X, SUBDIVISION NAME GRAPEVINE MILLS ADDITION BLOCK 1 LOT 1R3 H. SUGGS SURVEY, A-1415 J. GIBSON SURVEY, A-586 CITY OF GRAPEVINE, TARRANT COUNTY, TEXAS 1.0989 AC OR 47,869 SF ZONE: “CC” COMMUNITY COMMERCIAL DISTRICT DATE OF PREPARATION: DECEMBER 6, 2024 CASE NAME: GRAPEVINE MILLS MALL EV CASE NUMBER: CU24-51 LOCATION: 3000 GRAPEVINE MILLS PARKWAY BLOCK 1, LOT 1R3, GRAPEVINE MILLS ADDITION MAYOR SECRETARY DATE: PLANNING AND ZONING COMMISSION DATE: SHEET:OF APPROVAL DOES NOT AUTHORIZE ANY WORK IN CONFLICT AITH ANY CODES OR ORDINANCES. PLANNING SERVICES DEPARTMENT 2 MAGED HENEIN 102109 01/07/2025 86 VAN ACCESSIBLE ELECTRICVEHICLECHARGINGONLY RESERVEDPARKING VEHICLES NOT CHARGINGWILL BE TOWED AWAY ELECTRICVEHICLECHARGINGONLY RESERVEDPARKING VEHICLES NOT CHARGINGWILL BE TOWED AWAY ELECTRICVEHICLECHARGINGONLY RESERVEDPARKING VEHICLES NOT CHARGINGWILL BE TOWED AWAY ELECTRICVEHICLECHARGINGONLY RESERVEDPARKING VEHICLES NOT CHARGINGWILL BE TOWED AWAY TX220234 GRAPEVINE SIMON GRAPEVINE MILLS 3000 GRAPEVINE MILLS PARKWAY GRAPEVINE, TX 76051 REV DESCRIPTIONDATE CHECKED BY: DRAWN BY: PROJECT NO: IT IS A VIOLATION OF LAW FOR ANY PERSON, UNLESS THEY ARE ACTING UNDER THE DIRECTION OF A LICENSED PROFESSIONAL ENGINEER, TO ALTER THIS DOCUMENT. SHEET NUMBER SHEET TITLE R BLACK & VEATCH 11401 LAMAR AVENUE OVERLAND PARK, KS 66211 (913) 458-2000 ELECTRIFY AMERICA, LLC. 1950 OPPORTUNITY WAY SUITE 1500 RESTON, VA 20190 0 07/10/24 ISSUED FOR CONSTRUCTION NMB GAK 411370 1 09/24/24 REISSUED FOR CONSTRUCTION PURPOSE STATEMENT THE PURPOSE OF CONDITIONAL USE CU24-51 IS TO AMEND THE PREVIOUSLY APPROVED SITE PLAN CU24-01 (ORD. 2024-044) FOR A PLANNED COMMERCIAL CENTER IN EXCESS OF 1,000,000 SQUARE FEET OF GROSS, LEASABLE SPACES. THIS REQUEST IS SPECIFICALLY TO ADD THREE LEVEL 3 ELECTRIC VEHICLE (EV) CHARGING STATIONS TO THE SITE FOR PUBLIC USE. 2 12/09/24 CITY COMMENTS H. SUGGS SURVEY, A-1415 J. GIBSON SURVEY, A-586 3 01/07/25 CITY COMMENTS CASE NAME: GRAPEVINE MILLS MALL EV CASE NUMBER: CU24-51 LOCATION: 3000 GRAPEVINE MILLS PARKWAY BLOCK 1, LOT 1R3, GRAPEVINE MILLS ADDITION 3 SITE ELEVATION C-512" 6" 0 1' 2' 3' 4' 5' 6' 7' 3/8"=1'-0" SITE ELEVATION 2A2B3A3B 1A1B PROPOSED RESERVED PARKING FOR ELECTRIC VEHICLE ONLY SIGN MOUNTED ON LIGHT POLE PROPOSED LIGHT POLE WITH CAMERAS (TYP) (CAMERA BY OTHERS) PROPOSED DISPENSER (TYP) PROPOSED UTILITY TRANSFORMER PROPOSED POWER UNIT (TYP) PROPOSED CONCRETE PAD A D-1 PROPOSED UTILITY BOLLARD (TYP) PROPOSED RESERVED PARKING FOR ELECTRIC VEHICLE ONLY SIGNPROPOSED UTILITY METER MOUNTED ON TRANSFORMER PROPOSED CONCRETE CURB WITH GUTTER D D-4 EXISTING ASPHALT B D-3 PROPOSED RESERVED PARKING FOR ELECTRIC VEHICLE ONLY SIGN (TYP) B D-3 A D-3 B D-3 A D-3 C D-3 E D-3 D D-3 PROPOSED EQUIPMENT PROTECTION BOLLARD (TYP) B D-2 PROPOSED EQUIPMENT ENCLOSURE A D-4 9' - 1 1 / 4 " 1. LIGHT FIXTURES EXCLUDING ACCENT LIGHTING OF ARCHITECTURAL BUILDING FEATURES AND LIGHTING OF PUBLIC ART OR PUBLIC MONUMENTS SHALL BE MOUNTED NO HIGHER THAN THE HIGHEST POINT OF THE PRIMARY STRUCTURE ON THE PROPERTY. IN NO CASE SHALL LIGHT POLES BE GREATER THAN 30 FEET IN HEIGHT. 2. OFF PREMISE ADVERTISING IS PROHIBITED. NOTES 8' - 2 " (T Y P ) 18 ' - 0 " 5' - 4 " 2 2 2 2 2 23 SITE PLAN FOR GRAPEVINE MILLS MALL EV LOT X-Y, BLOCK X, SUBDIVISION NAME GRAPEVINE MILLS ADDITION BLOCK 1 LOT 1R3 H. SUGGS SURVEY, A-1415 J. GIBSON SURVEY, A-586 CITY OF GRAPEVINE, TARRANT COUNTY, TEXAS 1.0989 AC OR 47,869 SF ZONE: “CC” COMMUNITY COMMERCIAL DISTRICT DATE OF PREPARATION: DECEMBER 6, 2024 CASE NAME: GRAPEVINE MILLS MALL EV CASE NUMBER: CU24-51 LOCATION: 3000 GRAPEVINE MILLS PARKWAY BLOCK 1, LOT 1R3, GRAPEVINE MILLS ADDITION MAYOR SECRETARY DATE: PLANNING AND ZONING COMMISSION DATE: SHEET:OF APPROVAL DOES NOT AUTHORIZE ANY WORK IN CONFLICT AITH ANY CODES OR ORDINANCES. PLANNING SERVICES DEPARTMENT B D-1 C D-1 D D-1 E D-1 B D-1 3 3 3 2 MAGED HENEIN 102109 5  TX220234 GRAPEVINE SIMON GRAPEVINE MILLS 3000 GRAPEVINE MILLS PARKWAY GRAPEVINE, TX 76051 REV DESCRIPTIONDATE CHECKED BY: DRAWN BY: PROJECT NO: IT IS A VIOLATION OF LAW FOR ANY PERSON, UNLESS THEY ARE ACTING UNDER THE DIRECTION OF A LICENSED PROFESSIONAL ENGINEER, TO ALTER THIS DOCUMENT. SHEET NUMBER SHEET TITLE R BLACK & VEATCH 11401 LAMAR AVENUE OVERLAND PARK, KS 66211 (913) 458-2000 ELECTRIFY AMERICA, LLC. 1950 OPPORTUNITY WAY SUITE 1500 RESTON, VA 20190 0 07/10/24 ISSUED FOR CONSTRUCTION NMB GAK 411370 1 09/24/24 REISSUED FOR CONSTRUCTION PURPOSE STATEMENT THE PURPOSE OF CONDITIONAL USE CU24-51 IS TO AMEND THE PREVIOUSLY APPROVED SITE PLAN CU24-01 (ORD. 2024-044) FOR A PLANNED COMMERCIAL CENTER IN EXCESS OF 1,000,000 SQUARE FEET OF GROSS, LEASABLE SPACES. THIS REQUEST IS SPECIFICALLY TO ADD THREE LEVEL 3 ELECTRIC VEHICLE (EV) CHARGING STATIONS TO THE SITE FOR PUBLIC USE. 2 12/09/24 CITY COMMENTS H. SUGGS SURVEY, A-1415 J. GIBSON SURVEY, A-586 3 01/07/25 CITY COMMENTS CASE NAME: GRAPEVINE MILLS MALL EV CASE NUMBER: CU24-51 LOCATION: 3000 GRAPEVINE MILLS PARKWAY BLOCK 1, LOT 1R3, GRAPEVINE MILLS ADDITION 3 EQUIPMENT DETAILS D-4 NO SCALE NO SCALE NO SCALE B D A 1 1 TYPICAL TREX FENCE ELEVATION 8' - 0 " 2'-0" DIAMETER CONCRETE FOOTING (TYP) GRADE 6" M I N (T Y P ) 2'-0" (TYP) 8'-0" MAX 6" TREX FENCE ELEVATION SECTION 1-1 (4) #7 REBAR EQUALLY SPACED 3" COVER #3 REBAR HOOPS (3) #3 REBAR HOOPS @ 2" SPACING #3 REBAR HOOPS @ 6" MAX. SPACING TREX SECLUSION 50% SEMI-PRIVACY COMPOSITE FENCE (SUPPLIED BY CONTRACTOR) LOCKEY STYLE 285P MED DUTY LEVER WITH PASSAGE FOR PANIC EXITS OUTSIDE COMPOUND SINGLE GATE LOCK DETAIL W/ KEYPAD PANIC BAR (INSIDE) INSIDE COMPOUND PANIC BAR LOCKEY COMPATIBLE PANIC SHIELD ATTACHED TO TREX FENCE POST TREX FENCE POST (TYP) NOTE 1. CONTRACTOR SHALL UTILIZE LOCKEY STYLE 285P MED DUTY LEVER WITH PASSAGE FOR PANIC EXITS OR APPROVED EQUAL WITH COLOR TO MATCH. PURCHASE ACCESSORIES AS NECESSARY.41 " A B O V E F I N I S H G R A D E TREX GATE (TYP) TREX FENCE POST (TYP) TREX GATE (TYP) NOTES 1. COLOR: 2. PROPOSED TREX SECLUSION COMPOSITE FENCE SHALL MEET THE FOLLOWING REQUIREMENTS. WIND SPEED = 3. FENCE IS TO BE INSTALLED PLUMB. SINGLE GATE DETAIL TREX SECLUSION 50% SEMI-PRIVACY COMPOSITE FENCE (SUPPLIED BY CONTRACTOR) TYPICAL TREX FENCE DETAIL TREX FENCE POST (TYP)(BY OTHERS) 2'-0" Ø CONCRETE FOOTING MAX GUARD PANIC BARMAX GUARD PANIC BAR 46.25" IDEAL A - 3" A D-1 TREX FENCE POST (TYP) (BY OTHERS) 4' - 0 " C - NO SCALE C 3 115 MPH, SEISMIC: SDS = 1.0G, SEISMIC DESIGN CATEGORY D. "WINCHESTER GREY"2 2 3 SITE PLAN FOR GRAPEVINE MILLS MALL EV LOT X-Y, BLOCK X, SUBDIVISION NAME GRAPEVINE MILLS ADDITION BLOCK 1 LOT 1R3 H. SUGGS SURVEY, A-1415 J. GIBSON SURVEY, A-586 CITY OF GRAPEVINE, TARRANT COUNTY, TEXAS 1.0989 AC OR 47,869 SF ZONE: “CC” COMMUNITY COMMERCIAL DISTRICT DATE OF PREPARATION: DECEMBER 6, 2024 CASE NAME: GRAPEVINE MILLS MALL EV CASE NUMBER: CU24-51 LOCATION: 3000 GRAPEVINE MILLS PARKWAY BLOCK 1, LOT 1R3, GRAPEVINE MILLS ADDITION MAYOR SECRETARY DATE: PLANNING AND ZONING COMMISSION DATE: SHEET:OF APPROVAL DOES NOT AUTHORIZE ANY WORK IN CONFLICT AITH ANY CODES OR ORDINANCES. PLANNING SERVICES DEPARTMENT CONCRETE CURB DETAIL 1. 1/2" PRE MOLDED EXPANSION JOINTS SHALL BE PLACED AT POINTS OF CURVATURE, CURB RETURNS, CURB INLETS, AND AT 250' CENTERS. CONTRACTION JOINTS SHALL BE 2" DEEP, 3/16" WIDE, AND PLACED AT 15' INTERVALS EQUALLY SPACED BETWEEN EXPANSION JOINTS. 2. ABOVE GRADE DIMENSIONS AND BATTER MAY BE ADJUSTED TO MATCH EXISTING CURB ON SITE. 2'-0" 4"8" 2 " 8" 4 1 / 2 " 2" 6" 7" 1' - 0 " 6" 8"4" MATCH PAVEMENT ELEVATION R=1/4" FINISHED GRADE SLOPE 1/2" PER FT PIVOT @ LIP OF CURB MATCH PAVEMENT ELEVATION SEE TYPE B FOR REINF 3-#4 BARS FINISHED GRADE R=1/4" R=2" TYPE B TYPE B-1 NOTE 3 3 2 MAGED HENEIN 102109 01/07/2025 88