Loading...
HomeMy WebLinkAboutSFADD2025-000510RECEIVED: 2/11/2025 DATE OF ISSUAIR 0 A ,IM 25-000510 _ " — 2727 NEWCASTLE DRIVE PERMIT #: 25-000510 2ND STORY ADDITION / REMODEL BUILDING PERMIT APPLICATION ELECTRONIC REVIEW (PLEASE PRINT LEGIBLY — COMPLETE ENTIRE FORM) JOB ADDRESS: 2727 Newcastle Di LOT: t1 BLOCK: SUBDIVISION: Cantarhury VIIiAn P. BUILDING CONTRACTOR (company name): Sierra Fine Custom Homes CURRENT MAILING ADDRESS: 1801 Greenhaven Ln CITY/STATE/ZIP: nraravine TX 7fnr;l PROPERTY OWNER: Ste:>hanie Barber/Jordan Abed CURRENT MAILING ADDRESS: _Z727 NAwrr,j5jjCpr CITY/STATE/ZIP: nranavina TX 7f1n51 PROJECT VALUE: $ass wo PH: # 817-733-4371 SUITE # Fax # PHONE NUMBER: A17-4.i5-713.'3 FIRE SPRINKLERED? YES NO ,r WHAT TRADES WILL BE NEEDED? (Check ones that apply) ELECTRIC x PLUMBING X MECHANICAL X DESCRIPTION OF WORK TO BE DONE: 2nd Story Addition 937 sf (Consist of living area, game room, flex room, bedroom & bath) Remodel 270 sf of existing first floor pocket office/study into new pocket office and staircase. [Work requires changing USE OF BUILDING OR STRUCTURE • N electrical service from above ground to underground with customer's electric service provider] NAME OF BUSINESS: NSA Total Square Footage under roof: 3F32 Square Footage of alteration/addition: 1937 Addition, 270 Alteration I hereby certify that plans have been reviewed and the building will be inspected by a certified energy code inspector in accordance with State Law. Plan review and inspection documentation shall be made available to the Building Department (required for new buildings, alterations and additions) ❑ I hereby certify that plans have been submitted to the Texas Department of Licensing and Regulation for Accessibility Review. Control Number: (Not required for 1 & 2 family dwellings) ❑ I hereby certify that an asbestos survey has been conducted for this structure in accordance with the regulatory requirements of the Texas Department of Health. (REQUIRED FOR DEMOLITIONS, ADDITIONS AND OR ALTERATION TO COMMERCIAL AND PUBLIC BUILDINGS) I hereby certify that the foregoing is correct to the best of my knowledge and all work will be performed according to the documents approved by the Building Department and in compliance with the City Of Grapevine Ordinance regulating construction. It is understood that the issuance of this permit does not grant or authorize any violation of any code or ordinance of the City Of Grapevine. I FURTHERMORE UNDERSTAND THAT PLANS AND SPECIFICATIONS ARE NOT REVIEWED FOR HANDICAPPED ACCESSIBILITY BY THE CITY, AND THAT THE DESIGN PROFESSIONAL/OWNER IS RESPONSIBLE FOR OBTAINING SUCH APPR 'AL FROM TH PROPRIATE STATE AND OR FEDERAL AGENCY(S). PRINT NAME: Mark Mullins SIGNATURE �Ir PHONE #: l9401 Rq7-4321 EMAIL: ❑ CHECK BOX IF PREFERRED TO BE CONTACTED BY E-MAIL THE FOLLOWING IS TO BE COMPLETED BY THE BUILDING INSPECTION DEPARTMENT Construction Type: �j Permit Valuation: $ Setbacks Approval to Issue Occupancy Group: R2.3 Fire Sprinkler: YES NO Front: Electrical T� Division: Building Depth: Zoning: f �' - / Z, S" Building Width: Occupancy Load: Grease TraD Plan Review Approval: Date: Site Plan Approval: Date: Fire Department: Date: Public Works Department: Date: Health Department: Date: Approved for Permit: Date: Lot Drainage Submitted: Approved: P.O. BOX 95104, GRAPEVINE, TX 76099 (617) 410-3165 Left: Rear: Right: Building Permit Fee: Plumbing v 1.11 Mechanical Hood 7� Plan Review Fee: Lot Drainage Fee: 1 Sewer Availability Rate: Water Availability Rate: (J 1 Total Fees: Total Amount Due: 1207.00 v • ��(� O:FORMS\DSPERMITAPPLI3ONS�02-Re .11/04,5/007,11109,4111,2/19 City of Grapevine Building - Residential PO Box 95104 Addition Grapevine, Texas 76099 817) 410-3166 Project # 25-000510 Project Description: 2nd Story Addition 937 sf (Consist of living area, game room, flex room, bedroom & bath) Remodel 270 sf of existing first floor pocket office/study into new pocket office and staircase. [Work requires changing electrical service from above ground to underground with customer's electric... sprvim— nroviderl (ELECTRONIC REVIEW( Issued on: 03/07/2025 at 8:57 AM ADDRESS INSPECTIONS 2727 Newcastle Dr Grapevine, TX 76051 1. Building Framing 2. Building Bracing / Sheathing LEGAL 3. Building Wall Tie Inspection Canterbury Village Blk 4 Lot 8 INFORMATION FIELDS S Canterbury Village Block —APPLICANT NAME (Individual) 4 Lot 8 **APPLICANT PHONE NUMBER PERMIT HOLDER APPLICANT E-MAIL Mike McKellop VALUATION Sierra Fine Custom Horn Square Footage es * CONSTRUCTION TYPE (817) 733-9371 * OCCUPANCY GROUP COLLABORATORS DOCUMENTS - MISC 01 - Mike McKellop Sierra Fine Custom DOCUMENTS - MISC 02 Homes * ZONING DISTRICT (817) 733-9371 APPROVED TO ISSUE ELECTRIC OWNERS APPROVED TO ISSUE MECHANICAL • Stephanie Barber APPROVED TO ISSUE PLUMBING FEE Building Permit Fee, R-3 (Addition) SF TOTALS 0—fllri_L'I���l 5 4. Building Energy Code 5. Building Final Mark Mullins 9405974321 325000 1207 VB R-3 APPLICATION.pdf, RESCHECK.pdf ARCHITECTURAL PLANS.pdf, FRAMING PLANS.pdf R-12.5 YES YES YES TOTAL PAID DUE $ 1,207.00 $ 1,207.00 $ 1,207.00 $1,207.00 $ 1,207.00 $ 0.00 I HEREBY CERTIFY THAT THE FOREGOING IS CORRECT TO THE BEST OF MY KNOWLEDGE AND ALL WORK WILL BE PERFORMED ACCORDING TO THE DOCUMENTS APPROVED BY THE BUILDING DEPARTMENT AND IN COMPLIANCE WITH THE CITY OF GRAPEVINE ORDINANCE REGULATING Page 1/2 MYGOV.US 25-000510, 03/07/2025 at 8:57 AM Issued by. Courtney Cogbum City of Grapevine NOTICES CONSTRUCTION. IT IS UNDERSTOOD THAT THE ISSUANCE OF THIS PERMIT DOES NOT GRANT OR AUTHORIZE ANY VIOLATION OF ANY CODE OR ORDINANCE OF THE CITY OF GRAPEVINE. I FURTHERMORE UNDERSTAND THAT PLANS AND SPECIFICATIONS ARE NOT REVIEWED FOR HANDICAPPED ACCESSIBILITY BY THE CITY AND THAT THE DESIGN PROFESSIONAL I OWNER IS RESPONSIBLE FOR OBTAINING SUCH APPROVAL FROM THE APPROPRIATE STATE AND OR FEDERAL AGENCY(S). Signature Building - Residential Addition Project # 25-000510 March 07, 2025 Date GR.+.�FV t ,•a •r ,:. y 1) ALL work must be done in compliance with the 2021 INTERNATIONAL BUILDING CODE. ** ALL work ISSUED prior to January 1, 2024, must be done in compliance with the 2006 INTERNATIONAL BUILDING CODE. 2) City Approved Stamped Plans must be on -site for ALL INSPECTIONS. 3) Project address must be clearly posted at the job site. NOTES > 24 HOUR INSPECTION NUMBER METRO (817) 410-3010, CUT OFF TIME FOR A.M. INSPECTION IS 7:30 A.M. -- CUT OFF TIME FOR P.M. INSPECTION IS 12:30 P.M. > PERMIT ISSUED IN ACCORDANCE WITH APPLICATION ON FILE IN THIS OFFICE. THIS PERMIT SHALL EXPIRE IF WORK IS NOT COMMENCED WITHIN (180 DAYS) OF ISSUANCE OR IF WORK IS SUSPENDED OR ABANDONED FOR A PERIOD OF (180 DAYS). THE ISSUANCE OR GRANTING OF THIS PERMIT AND / OR APPROVAL OF PLANS, SPECIFICATIONS AND COMPUTATIONS SHALL NOT BE CONSTRUED TO BE A PERMIT FOR, OR AN APPROVAL OF, ANY VIOLATION OF ANY OF THE PROVISIONS OF THE CODES AND ORDINANCES OF THE CITY OF GRAPEVINE. THE ISSUANCE OF A PERMIT BASED ON PLANS, SPECIFICATIONS, AND OTHER DATA SHALL NOT PREVENT THE BUILDING DEPARTMENT FROM THEREAFTER REQUIRING THE CORRECTION OF ERRORS IN SAID PLANS, SPECIFICATIONS, AND OTHER OR REQUIRING CORRECTIONS OF THE CONSTRUCTION ITSELF Page 2/2 MYGOV.US 25-000510, 03107/2025 at 8:57 AM Issued by: Courtney Gogbum INTERNATIONAL RESIDENTIAL CODE 2021 GRAPEVINE, TEXAS 115 MPH 5 PSF GRAPEVINE, TEXAS 2021 R301.1.3 DR A W N B Y : DA N I E L T U C K E R DA T E : 02 / 0 5 / 2 0 2 5 SC A L E : 1/ 8 " = 1 ' - 0 " SI E R R A F I N E C U S T O M H O M E S PL A N # : 28 2 9 CA N T E R B U R Y V I L L A G E LO T : 8 B L O C K : -- - - 27 2 7 N E W C A S T L E D R I V E GR A P E V I N E , TX 44 1 6 K E L L E R H I C K S R O A D FO R T W O R T H , T X 7 6 2 4 4 (8 1 7 ) 3 7 9 - 0 8 6 6 in f o @ n o r t e x f o u n d a t i o n . c o m NO R T E X F O U N D A T I O N D E S I G N S , I N C . JOB NUMBER 25-194196 TX FIRM REGISTRATION#: F-6417 1. ENGINEERED DESIGN CITY/MUNICIPALITY: GRND SNOW LOAD: BASIC WIND SPEED: CODE: EDITION: 1.1 THE ENGINEERED DESIGN OF THIS STRUCTURE IS INTENDED TO MEET THE FRAMING ENGINEERED DESIGN REQUIREMENTS AS ISSUDED BY THE CITY / COUNTY OF 1.2 THE ENGINEERED DESIGN OF THIS STRUCTURE IS DESIGNED FOR A BASIC WIND SPEED OF PER. INTERNATIONAL RESIDENTIAL CODE, EDITION. 1.3 PER IRC THE EXTENT OF THE ENGINEERED DESIGN "SHALL ONLY DEMONSTRATE COMPLIANCE OF THESE NONCONVENTIONAL ELEMENTS WITH OTHER APPLICABLE PROVISIONS AND SHALL BE COMPATIBLE WITH THE PERFORMANCE OF THE CONVENTIONAL FRAMED SYSTEMS." 1.4 ITEMS NOT COVERED ON THESE DRAWINGS SHALL MAINTAIN STRICT COMPLIANCE WITH THE I.R.C. FR-1a LATERAL BRACING DETAILS STANDARD DETAILS STANDARD DETAILS STANDARD DETAILS FR-2 FR-1b DTL-2 DTL-4 DTL-5 DTL-3 DTL-1 LB-1a LB-1b TABLE OF CONTENTS PAGE #DESCRIPTION REV. DATE GFD-1 IBD-1 STANDARD DETAILS 1st FLOOR LATERAL BRACING PLAN 2nd FLOOR LATERAL BRACING PLAN 1st FLOOR CEILING JOISTS FRAMING PLAN 2nd FLOOR CEILING JOISTS FRAMING PLAN ROOF RAFTER FRAMING PLAN GENERAL FRAMING DETAILS INTERIOR BRACING DETAIL EXISTING FLOORPLAN NOT IN SCOPE EXISTING FLOORPLAN NOT IN SCOPE EXISTING FLOORPLAN NOT IN SCOPE EXISTING FLOORPLAN NOT IN SCOPE EXISTING FLOORPLAN NOT IN SCOPE EXISTING FLOORPLAN NOT IN SCOPE * ** * D B B DR A W N B Y : DA N I E L T U C K E R DA T E : 02 / 0 5 / 2 0 2 5 SC A L E : 1/ 8 " = 1 ' - 0 " SI E R R A F I N E C U S T O M H O M E S PL A N # : 28 2 9 CA N T E R B U R Y V I L L A G E LO T : 8 B L O C K : -- - - 27 2 7 N E W C A S T L E D R I V E GR A P E V I N E , TX 44 1 6 K E L L E R H I C K S R O A D FO R T W O R T H , T X 7 6 2 4 4 (8 1 7 ) 3 7 9 - 0 8 6 6 in f o @ n o r t e x f o u n d a t i o n . c o m NO R T E X F O U N D A T I O N D E S I G N S , I N C . JOB NUMBER 25-194196 TX FIRM REGISTRATION#: F-6417 LB / 1a 1st FLOOR LATERAL BRACING PLAN SHEET NOTES: * HOLD DOWN NOT NECESSARY AT THIS LOCATION IF HEADER IS CONTINUOUS OVER SUPPORT INSTALL TIE-DOWNS AT INDICATED LOCATIONS 1.ATTACH EXTERIOR POST (IF PRESENT) TO FOUNDATION BELOW AND TO FRAMING ABOVE PER THE TYPICAL DETAIL ON SHEET DTL-3 2.INSTALL FLOOR-TO-FLOOR SHEAR WALL PANEL STRAPS PER TYPICAL DETAIL ON SHEET DTL-2. 3.FOR GENERAL NOTES, SEE SHEET DTL-2. 4.FOR LATERAL BRACING DETAILS & DESCRIPTIONS, SEE SHEETS DTL-1, DTL-2 & DTL-3. D 4'-0"A D D A D 4' - 0 " IU D D 4'-0" IU D D THESE PERIMETER WALLS ARE INTERIOR AND NOT A PART OF WIND BRACING DESIGN SHOWN ON THESE PLANS. THESE WALLS WILL BE SUFFICIENTLY BRACED WITH SHEETROCK ON THE INSIDE FACE. DR A W N B Y : DA N I E L T U C K E R DA T E : 02 / 0 5 / 2 0 2 5 SC A L E : 1/ 8 " = 1 ' - 0 " SI E R R A F I N E C U S T O M H O M E S PL A N # : 28 2 9 CA N T E R B U R Y V I L L A G E LO T : 8 B L O C K : -- - - 27 2 7 N E W C A S T L E D R I V E GR A P E V I N E , TX 44 1 6 K E L L E R H I C K S R O A D FO R T W O R T H , T X 7 6 2 4 4 (8 1 7 ) 3 7 9 - 0 8 6 6 in f o @ n o r t e x f o u n d a t i o n . c o m NO R T E X F O U N D A T I O N D E S I G N S , I N C . JOB NUMBER 25-194196 TX FIRM REGISTRATION#: F-6417 LB / 1b 2nd FLOOR LATERAL BRACING PLAN SHEET NOTES: 1.ATTACH EXTERIOR POST (IF PRESENT) TO FOUNDATION BELOW AND TO FRAMING ABOVE PER THE TYPICAL DETAIL ON SHEET DTL-3 2.INSTALL FLOOR-TO-FLOOR SHEAR WALL PANEL STRAPS PER TYPICAL DETAIL ON SHEET DTL-2. 3.FOR GENERAL NOTES, SEE SHEET DTL-2. 4.FOR LATERAL BRACING DETAILS & DESCRIPTIONS, SEE SHEETS DTL-1, DTL-2 & DTL-3. EXISTING FLOORPLAN NOT IN SCOPE OPEN TO ABOVE FLOOR SYSTEM BY OTHERS FLOOR SYSTEM BY OTHERS FLOOR SYSTEM BY OTHERS FLOOR SYSTEM BY OTHERS EXISTING FLOORPLAN NOT IN SCOPE EXISTING FLOORPLAN NOT IN SCOPE EXISTING FLOORPLAN NOT IN SCOPE EXISTING FLOORPLAN NOT IN SCOPE EXISTING FLOORPLAN NOT IN SCOPE (2) 1 3/4" x 11 1/4" 2.0E Microllam LVL (2 ) 1 3 / 4 " x 1 1 1 / 4 " 2. 0 E M i c r o l l a m L V L (4 ) 1 3 / 4 " x 1 6 " 2. 0 E M i c r o l l a m L V L (4 ) 1 3 / 4 " x 1 6 " 2. 0 E M i c r o l l a m L V L (2)6' 2x12's (3)6' 2x12's (3 ) 1 3 / 4 " x 1 1 1 / 4 " 2. 0 E M i c r o l l a m L V L (2)4' 2x12's 2021 2021 DR A W N B Y : DA N I E L T U C K E R DA T E : 02 / 0 5 / 2 0 2 5 SC A L E : 1/ 8 " = 1 ' - 0 " SI E R R A F I N E C U S T O M H O M E S PL A N # : 28 2 9 CA N T E R B U R Y V I L L A G E LO T : 8 B L O C K : -- - - 27 2 7 N E W C A S T L E D R I V E GR A P E V I N E , TX 44 1 6 K E L L E R H I C K S R O A D FO R T W O R T H , T X 7 6 2 4 4 (8 1 7 ) 3 7 9 - 0 8 6 6 in f o @ n o r t e x f o u n d a t i o n . c o m NO R T E X F O U N D A T I O N D E S I G N S , I N C . JOB NUMBER 25-194196 TX FIRM REGISTRATION#: F-6417 FR / 1aDESIGNATED STORAGE AREA WHERE CEILING JOISTS ARE SIZED TO ACCOMMODATE 10/20psf ATTIC STORAGE LOAD. PER I.R.C. TABLE R802.4(2). BUILDER TO ADVISE HOMEOWNER THAT USE OF AREAS OUTSIDE OF HATCHED AREA FOR STORAGE COULD RESULT IN EXCESS DEFLECTION AND CAUSE CRACKS IN JOISTS and/or CEILING COVERINGS.1ST FLOOR CEILING JOIST FRAMING PLAN ALL CEILING JOISTS SHALL BE #2 S.Y.P. 2x6's @ 24" O.C. (U.N.O.) 2x102x10 #2 YP. 2x1020'-11"18'-1" 2x10 14'-9" #2 YP. 26'-0"25'-7"2x10 20'-11"2x10 2x6 2x8 2x4 2x4 2x8 2x6 9'-3" 17'-7" 13'-11" 12" O.C. 8'-0" 12'-0" 15'-3" 16" O.C. 2x8 2x6 2x4 2x4 6'-7" 12'-6" 9'-10" 2x8 2x6 24" O.C. 11'-10" 24'-7" 18'-8" 12" O.C. 10'-9"2x4 21'-7" 16'-11" 2x8 2x6 16" O.C. 2x4 9'-3" 13'-11" 17'-7"2x8 2x6 24" O.C. MAXIMUM CLEAR SPAN FOR CEILING JOIST-W./ GYPSUM CLG.10 LBS LIVE , 5 LBS DEAD (NO ATTIC STORAGE) MAXIMUM CLEAR SPAN FOR CEILING JOIST-W./ GYPSUM CLG.20 LBS LIVE , 10LBS DEAD (ATTIC STORAGE) BUILDER SHALL PROVIDE CONNECTIONS AND SUPPORTING ELEMENTS FOR FRAMING SHOWN ON THIS SHEET PER I.R.C. AND LOCAL CODE REQUIREMENTS 1.JOIST AND BEAM HANGERS, WHERE SPECIFIED, SHALL BE FULLY NAILED PER MANUFACTURER'S CATALOG SPECIFICATIONS. SEE CHART ON SHEETS DTL-3 & DTL-6 FOR PRE-APPROVED HANGER SIZES. 2.MULTIPLE-STUD COLUMN SUPPORTS, WHERE SPECIFIED, SHALL HAVE EACH PLY NAILED TOGETHER WITH 10d COMMONS @ 9" O.C. (2 ROWS OF NAILS REQUIRED FOR 2x6 STUDS). 3.DECKING FOR UNINHABITABLE ATTICS WITH LIMITEDSTORAGE SHALL BE MINIMUM 7/16" PLYWOOD or OSB, WITH A SPAN RATING THAT MEETS or EXCEEDS THE CEILING JOIST SPACING. 4.MULTIPLE-PLY BEAMS, WHERE SPECIFIED, SHALL HAVE EACH PLY NAILED TOGETHER WITH 2 ROWS OF 16d SHORTS x0.131 GUN NAILS @ 12" O.C. (3 ROWS OF NAILS REQUIRED FOR BEAMS EXCEEDING 12" MIN DEPTH). 5.REFER TO I.R.C. TABLE R502.3.1(2) FOR FLOOR JOISTS SPANS WHERE APPLICABLE. 6.REFER TO I.R.C. TABLES R802.4(1) AND R802.4(2) FOR CEILING JOISTS SPAN CHARTS. (2)8' 2x12's WITH 1/2" OSB CONT. FILLER (2)8' 2x12's WITH 1/2" OSB CONT. FILLER Use Rafters or False Rafters as Ceiling Joists Use Rafters or False Rafters as Ceiling Joists Us e R a f t e r s o r F a l s e Ra f t e r s a s C e i l i n g J o i s t s Us e R a f t e r s o r F a l s e Ra f t e r s a s C e i l i n g J o i s t s Use Rafters or False Rafters as Ceiling Joists Use Rafters or False Rafters as Ceiling Joists Us e R a f t e r s o r F a l s e Ra f t e r s a s C e i l i n g J o i s t s Us e R a f t e r s o r F a l s e Ra f t e r s a s C e i l i n g J o i s t s (3)6' 2x12's 8' 6' 8' 8'8'8' 2- 8 ' ( 2 x 1 2 ) 8'8'8'8' 10' 10' 10' 2-10' (2x8) 6' 6' 6' 6' 6' 6' 4' 14 ' ( 2 x 8 ) 14 ' ( 2 x 8 ) 14 ' ( 2 x 8 ) 16 ' ( 2 x 8 ) 16 ' ( 2 x 8 ) 16 ' ( 2 x 8 ) 16 ' ( 2 x 8 ) 16 ' ( 2 x 8 ) 16 ' ( 2 x 8 ) 16 ' ( 2 x 8 ) (2 ) 6 ' 2 x 1 2 ' s 2x8's @ 24" O.C (2 ) 1 0 ' 2 x 1 2 ' s 2- 1 0 ' ( 2 x 8 ) 2- 1 0 ' ( 2 x 8 ) 2- 1 0 ' ( 2 x 8 ) 10 ' 10 ' 10 ' (2 ) 1 3 / 4 " x 1 1 1 / 4 " 2. 0 E M i c r o l l a m L V L F L O A T I N G (2 ) 1 3 / 4 " x 1 1 1 / 4 " 2. 0 E M i c r o l l a m L V L F L O A T I N G 2021 2021 DR A W N B Y : DA N I E L T U C K E R DA T E : 02 / 0 5 / 2 0 2 5 SC A L E : 1/ 8 " = 1 ' - 0 " SI E R R A F I N E C U S T O M H O M E S PL A N # : 28 2 9 CA N T E R B U R Y V I L L A G E LO T : 8 B L O C K : -- - - 27 2 7 N E W C A S T L E D R I V E GR A P E V I N E , TX 44 1 6 K E L L E R H I C K S R O A D FO R T W O R T H , T X 7 6 2 4 4 (8 1 7 ) 3 7 9 - 0 8 6 6 in f o @ n o r t e x f o u n d a t i o n . c o m NO R T E X F O U N D A T I O N D E S I G N S , I N C . JOB NUMBER 25-194196 TX FIRM REGISTRATION#: F-6417 FR / 1b 2x102x10 #2 YP. 2x1020'-11"18'-1" 2x10 14'-9" #2 YP. 26'-0"25'-7"2x10 20'-11"2x10 2x6 2x8 2x4 2x4 2x8 2x6 9'-3" 17'-7" 13'-11" 12" O.C. 8'-0" 12'-0" 15'-3" 16" O.C. 2x8 2x6 2x4 2x4 6'-7" 12'-6" 9'-10" 2x8 2x6 24" O.C. 11'-10" 24'-7" 18'-8" 12" O.C. 10'-9"2x4 21'-7" 16'-11" 2x8 2x6 16" O.C. 2x4 9'-3" 13'-11" 17'-7"2x8 2x6 24" O.C. MAXIMUM CLEAR SPAN FOR CEILING JOIST-W./ GYPSUM CLG.10 LBS LIVE , 5 LBS DEAD (NO ATTIC STORAGE) MAXIMUM CLEAR SPAN FOR CEILING JOIST-W./ GYPSUM CLG.20 LBS LIVE , 10LBS DEAD (ATTIC STORAGE) 1.JOIST AND BEAM HANGERS, WHERE SPECIFIED, SHALL BE FULLY NAILED PER MANUFACTURER'S CATALOG SPECIFICATIONS. SEE CHART ON SHEETS DTL-3 & DTL-6 FOR PRE-APPROVED HANGER SIZES. 2.MULTIPLE-STUD COLUMN SUPPORTS, WHERE SPECIFIED, SHALL HAVE EACH PLY NAILED TOGETHER WITH 10d COMMONS @ 9" O.C. (2 ROWS OF NAILS REQUIRED FOR 2x6 STUDS). 3.DECKING FOR UNINHABITABLE ATTICS WITH LIMITEDSTORAGE SHALL BE MINIMUM 7/16" PLYWOOD or OSB, WITH A SPAN RATING THAT MEETS or EXCEEDS THE CEILING JOIST SPACING. 4.MULTIPLE-PLY BEAMS, WHERE SPECIFIED, SHALL HAVE EACH PLY NAILED TOGETHER WITH 2 ROWS OF 16d SHORTS x0.131 GUN NAILS @ 12" O.C. (3 ROWS OF NAILS REQUIRED FOR BEAMS EXCEEDING 12" MIN DEPTH). 5.REFER TO I.R.C. TABLE R502.3.1(2) FOR FLOOR JOISTS SPANS WHERE APPLICABLE. 6.REFER TO I.R.C. TABLES R802.4(1) AND R802.4(2) FOR CEILING JOISTS SPAN CHARTS. DESIGNATED STORAGE AREA WHERE CEILING JOISTS ARE SIZED TO ACCOMMODATE 10/20psf ATTIC STORAGE LOAD. PER I.R.C. TABLE R802.4(2). BUILDER TO ADVISE HOMEOWNER THAT USE OF AREAS OUTSIDE OF HATCHED AREA FOR STORAGE COULD RESULT IN EXCESS DEFLECTION AND CAUSE CRACKS IN JOISTS and/or CEILING COVERINGS. ALL CEILING JOISTS SHALL BE #2 S.Y.P. 2x6's @ 24" O.C. (U.N.O.) BUILDER SHALL PROVIDE CONNECTIONS AND SUPPORTING ELEMENTS FOR FRAMING SHOWN ON THIS SHEET PER I.R.C. AND LOCAL CODE REQUIREMENTS 2ND FLOOR CEILING JOIST FRAMING PLAN 12 ' 12 ' 12 ' 12 ' 12 ' 12 ' 12 ' 12 ' 12 ' 12 ' 2' 4' 6' 10 ' 4' 2' 6' 8' 10 ' 12 ' 12 ' 2' 4' 6' 10 ' 12' 2' 4' 6' 10' 2' 4' 6' 10' 18 ' 4' 6' 8' 10 ' 12 ' 14 ' 16 ' 12 ' 14 ' 16 ' 14' 4' 6' 8' 10' 12' 14' 14' 6' 10' 18' 10' 12' 14' 16' 4' 6' 8' 10' 12' 14' 16' 8' 6' 4' 4' 12 ' 2' 4' 6' 10 ' 2' 4' 6' 10 ' 12' 2' 4' 6' 10' 12' 4' 6' 8' 10' 2' 4' 6' 10' 4' 6' 8' 10' 10 ' 4' 6' 6' 6' 6' 6' 6' 4' 6' 8' 10 ' 10 ' 10 ' 10 ' 4' 8' EXISTING ROOF PLAN EXISTING ROOF PLAN NOT IN SCOPE EXISTING ROOF PLAN NOT IN SCOPE EXISTING ROOF PLAN NOT IN SCOPE EXISTING ROOF PLAN NOT IN SCOPE EXISTING ROOF PLAN NOT IN SCOPE EXISTING ROOF PLAN NOT IN SCOPE EXISTING ROOF PLAN NOT IN SCOPE EXISTING ROOF PLAN NOT IN SCOPE EXISTING ROOF PLAN NOT IN SCOPE 2021 2021 DR A W N B Y : DA N I E L T U C K E R DA T E : 02 / 0 5 / 2 0 2 5 SC A L E : 1/ 8 " = 1 ' - 0 " SI E R R A F I N E C U S T O M H O M E S PL A N # : 28 2 9 CA N T E R B U R Y V I L L A G E LO T : 8 B L O C K : -- - - 27 2 7 N E W C A S T L E D R I V E GR A P E V I N E , TX 44 1 6 K E L L E R H I C K S R O A D FO R T W O R T H , T X 7 6 2 4 4 (8 1 7 ) 3 7 9 - 0 8 6 6 in f o @ n o r t e x f o u n d a t i o n . c o m NO R T E X F O U N D A T I O N D E S I G N S , I N C . JOB NUMBER 25-194196 TX FIRM REGISTRATION#: F-6417 FR / 2 1.RIDGE, HIP, VALLEY, AND PURLIN LOADS SHALL BE DISTRIBUTED TO WALLS OR BEAMS BELOW BY "T" BRACES. REFER TO "T-BRACE SCHEDULE" ON SHEET DTL-4 FOR SIZING INFO. THE "T" BRACES SHALL BE INSTALLED AT AN ANGLE GREATER THAN 45 DEGREES WITH THE HORIZONTAL. BRACE PURLINS AT 4'-0" O.C. MAX. 2.RAFTER SPANS EXCEEDING I.R.C. SPAN CHARTREQUIREMENTS (LISTED IN NOTE #4) WITH THE HORIZONTAL DISTANCE SHALL BE BRACED WITH A PURLIN. SEE SHEET DTL-4 FOR DETAILS. 3.THE ROOF SUPPORT FRAMING IS DESIGNED TO SUPPORT AN ASPHALT or COMPOSITION SHINGLE ROOF. VARIATIONS FROM THIS TYPE OF ROOF COVERING SYSTEM MUST BE BROUGHT TO THE ATTENTION OF THE FRAMING ENGINEER FOR RE-DESIGN. 4.REFER TO I.R.C. TABLES R802.5.1(1) AND R802.5.1(2) FOR ROOF RAFTER SPAN CHARTS, FOR COMPOSITION ROOFING MATERIAL. 5.REFER TO I.R.C. TABLES R802.5.1(3) AND R802.5.1(5) FOR ROOF RAFTER SPAN CHARTS; FOR SLATE ROOFING MATERIAL. 6.ANY CHANGES IN THE FIELD REGARDING ROOFING MATERIAL MUST BE BROUGHT TO NORTEX's ATTENTION FOR RE-DESIGN. 2x8 2x10 2x12 2x6 NO GYPSUM CEILING- STANDARD ROOF COVERING 20 LBS LIVE , 10 LBS DEAD MAXIMUM CLEAR SPAN FOR RAFTERS 17'-1" 20'-3" 23'-10" 13'-6" MAXIMUM CLEAR SPAN FOR RAFTERS W/ GYPSUM CEILING- STANDARD ROOF COVERING 20 LBS LIVE , 20 LBS DEAD 2x12 #2 YP. 12" O.C. 2x10 2x8 2x6 16'-10"2x122x1220'-8" 11'-8" 14'-9" 17'-6" 16" O.C. 2x10 2x8 2x6 24" O.C. 2x10 2x8 2x6 12'-1" 14'-4" 9'-6" 26'-0"2x12 #2 YP. 12" O.C. 23'-5" 19'-6" 14'-9" 2x8 2x10 2x6 2x1226'-0"19'-6" 2x8 2x10 2x6 16" O.C. 18'-6" 23'-2" 14'-1" 24" O.C. 13'-11" 16'-6" 11'-0" PER SECTION R802.3.1 OF THE I.R.C., RAFTER TIES or SOME OTHER METHOD OF RESISTING OUT THRUST SHALL BE INSTALLED WHERE CEILING JOISTS ARE PERPENDICULAR TO or ARE OTHERWISE NOT CONNECTED TO RAFTERS. SEE "CEILING PERPENDICULAR TO RAFTERS" DETAIL ON SHEET DTL-4 FOR TYPICAL INSTALLATION. BUILDER SHALL PROVIDE CONNECTIONS AND SUPPORTING ELEMENTS FOR FRAMING SHOWN ON THIS SHEET PER I.R.C. AND LOCAL CODE REQUIREMENTS ROOF RAFTER FRAMING PLAN ALL RAFTERS SHALL BE #2 S.Y.P. 2x6's @ 24" O.C. (U.N.O.) ALL HIPS, RIDGES & VALLEYS SHALL BE #2 S.Y.P. 2x8's (U.N.O.) IF SLATE ROOFING MATERIAL IS USED RAFTERS SHALL BE #2 S.Y.P. 2x8's @ 24" O.C. (U.N.O.) DR A W N B Y : DA N I E L T U C K E R DA T E : 02 / 0 5 / 2 0 2 5 SC A L E : N. T . S . SI E R R A F I N E C U S T O M H O M E S PL A N # : 28 2 9 CA N T E R B U R Y V I L L A G E LO T : 8 B L O C K : -- - - 27 2 7 N E W C A S T L E D R I V E GR A P E V I N E , TX 44 1 6 K E L L E R H I C K S R O A D FO R T W O R T H , T X 7 6 2 4 4 (8 1 7 ) 3 7 9 - 0 8 6 6 in f o @ n o r t e x f o u n d a t i o n . c o m NO R T E X F O U N D A T I O N D E S I G N S , I N C . JOB NUMBER 25-194196 TX FIRM REGISTRATION#: F-6417 DTL / 1 LATERAL BRACING DETAILSLATERAL BRACING DETAILS WINDOW or DOOR OPENING (WHEN PRESENT) 7/16" PLYWOOD or OSB SHEATHING WITH 8d COMMON NAILS AT 4" O.C. AT PANEL EDGES AND AT 12" O.C. IN FIELD DETAIL N WALL STIFFENER PANEL w/ (2) HOLD DOWNS SCALE: N.T.S 1/2" DIA ANCHOR ROD; DRILL AND INSTALL w/ SIMPSON SET EPOXY, 7" EMBEDMENT (ALTERNATIVELY, INSTALL 1/2" J-BOLT BEFORE CONCRETE POUR) 2-SIMPSON HTT4 w/ 5/8" DIA ANCHOR BOLT, INSTALLED W/SIMPSON SET EPOXY, 7" EMBEDMENT, [ALTERNATIVELY, INSTALL 2-SIMPSON STHD10 AND (2) 1/2" J-BOLTS (7" EMBED) BEFORE CONCRETE POUR] TOP PLATE ELEVATION 1/2" DIA ANCHOR ROD; DRILL AND INSTALL w/ SIMPSON SET EPOXY, 7" EMBEDMENT (ALTERNATIVELY, INSTALL 1/2" J-BOLT BEFORE CONCRETE POUR) 1-SIMPSON HTT4 w/ 5/8" DIA ANCHOR BOLT, INSTALLED W/SIMPSON SET EPOXY, 7" EMBEDMENT, [ALTERNATIVELY, INSTALL 2-SIMPSON STHD10 AND (2)1/2" J-BOLTS (7" EMBED) BEFORE CONCRETE POUR] TOP PLATE ELEVATION WINDOW or DOOR OPENING (WHEN PRESENT) 7/16" PLYWOOD or OSB SHEATHING WITH 8d COMMON NAILS AT 4" O.C. AT PANEL EDGES AND AT 12" O.C. IN FIELD DETAIL B WALL STIFFENER PANEL w/ HOLD DOWN IN CORNER SCALE: N.T.S NOTE: SEE PLAN FOR HOLD DOWN PLACEMENT SIMPSON HTT4 w/ 5/8" DIA ANCHOR ROD, INSTALLED W/SIMPSON SET EPOXY, (7" EMBEDMENT). [ALTERNATIVELY, INSTALL SIMPSON STHD10 BEFORE CONCRETE POUR] 1/2" DIA ANCHOR ROD; DRILL AND INSTALL W/SIMPSON SET EPOXY, 7" EMBEDMENT [ALTERNATIVELY, INSTALL 1/2" DIA. J-BOLT (7" EMBEDMENT) BEFORE CONCRETE POUR]. WALL CORNER or PANEL EDGE CLOSEST TO CORNER DETAIL G PERFORATED SHEARWALL CORNER DETAIL SCALE: N.T.S 4'-0" MINIMUM TOP PLATE ELEVATION 7/16" PLYWOOD OR OSB SHEATHING WITH 8d COMMON NAILS AT 4" O.C. AT PANEL EDGES AND AT 12" O.C. IN FIELD. PROVIDE 2X BLOCKING AT ALL HORIZONTAL PANEL JOINTS. 1x4 NOTCHED INTO STUDS. NOTCH MUST BEAR ON DIAGONAL or BE REINFORCED WITH METAL STRAP. OR 45 DEGREES (MIN.) TO 60 DEGREES (MAX.)NOTE: SEE PLAN FOR HOLD DOWN PLACEMENT M SHEATH CONTINUOUSLY AROUND CURVED WALL (ABOVE, BELOW, AND BETWEEN OPENINGS) WITH ENERGY BRACE 0.106" STRUCTURAL WALL SHEATHING (RED LABEL) OR EQUAL. PROVIDE BLOCKING AT ALL HORIZONTAL EDGES, AND VERTICAL EDGES SHALL OCCUR OVER STUDS. USE NO. 11 GAUGE 1 1/4" GALVANIZED STEEL ROOFING NAILS OR 7/16" CROWN X 1 1/4" LEG NO. 16 GAUGE GALVANIZED STEEL STAPLES @ 3" O.C. @ PANEL EDGES AND @ 6" O.C. IN FIELD. PANEL EDGES MAY BE BUTTED OR LAPPED 3/4" MINIMUM. TYPICAL WINDOW OPENING (WHEN PRESENT) TYPICAL DOOR OPENING (WHEN PRESENT) TOP PLATE ELEVATION REFER TO LATERAL BRACING PLAN FOR EXTENT OF SHEATHING REQUIRED SHEATH WALL AREAS ABOVE, BELOW, AND ADJACENT TO OPENINGS WITH 7/16" PLYWOOD or OSB. 2x BLOCKING SHALL BE INSTALLED AT ALL HORIZONTAL PANEL JOINTS, AND VERTICAL PANEL JOINTS SHALL OCCUR OVER STUDS. USE 8d COMMON NAILS @ 4" O.C. @ PANEL EDGES AND @ 12" O.C. IN THE FIELD. NOTE: THE ELEVATION SHOWN IS FOR ILLUSTRATIVE PURPOSES ONLY AND MAY DIFFER FROM ACTUAL CONDITIONS DETAIL D CONTINUOUSLY SHEATHED WALL SCALE: N.T.S 1/2" DIA ANCHOR ROD; DRILL AND INSTALL w/ SIMPSON SET EPOXY, 7" EMBEDMENT (ALTERNATIVELY, INSTALL 1/2" J-BOLT BEFORE CONCRETE POUR) 3,000 PSI CONCRETE 4'-0" MINIMUM TOP PLATE ELEVATION DETAIL A PERFORATED SHEARWALL DETAIL SCALE: N.T.S 1/2" DIA ANCHOR ROD; DRILL AND INSTALL w/ SIMPSON SET EPOXY, 7" EMBEDMENT (ALTERNATIVELY, INSTALL 1/2" J-BOLT BEFORE CONCRETE POUR) NOTE: USE A METALLISCANNER TO LOCATE EXISTING CABLES 7/16" PLYWOOD OR OSB SHEATHING WITH 8d COMMON NAILS AT 4" O.C. AT PANEL EDGES AND AT 12" O.C. IN FIELD. ALL EDGES SHALL BE BACKED INCLUDING HORIZONTAL JOINTS WHICH OCCUR IN WALLS ABOVE 8'-0". PROVIDE 2X BLOCKING AT ALL HORIZONTAL PANEL JOINTS. 1x4 NOTCHED INTO STUDS. NOTCH MUST BEAR ON DIAGONAL or BE REINFORCED WITH METAL STRAP. OR 45 DEGREES (MIN.) TO 60 DEGREES (MAX.) TYPICAL DOOR OPENING (WHEN PRESENT) TOP PLATE ELEVATION REFER TO LATERAL BRACING PLAN FOR EXTENT OF SHEATHING REQUIRED SHEATH WALL AREAS ABOVE, BELOW, AND ADJACENT TO OPENINGS WITH 1/2" GYPSUM SHEATHING ON BOTH SIDES. 2x BLOCKING SHALL BE INSTALLED AT ALL HORIZONTAL PANEL JOINTS, AND VERTICAL PANEL JOINTS SHALL OCCUR OVER STUDS. USE 1/2" GALV. ROOFING NAIL OR STAPLE x 1 5/8" LONG; OR 1 5/8" SCREWS TYPE W OR S AT 7" O.C. FOR EDGE AND FIELD. NOTE: THE ELEVATION SHOWN IS FOR ILLUSTRATIVE PURPOSES ONLY AND MAY DIFFER FROM ACTUAL CONDITIONS DETAIL I INTERIOR SHEATHING DETAIL SCALE: N.T.S TYPICAL HALLWAY OR ROOM (WHEN PRESENT) 4" MI N . 3,000 PSI CONCRETE INSTALL SIMPSON 1/2" x 5" LG. TITEN HD (THD50600H) @ 4'-0" O.C. PER MFG.'S INSTRUCTIONS NOTE: RED THERMO-PLY IS AN ALLOWABLE SUBSTITUTION FOR OSB/PLYWOOD SHEATHING. SEE GFD-1 FOR ADDITIONAL INFORMATION. 2021 GRAPEVINE, TEXAS 115 MPH DR A W N B Y : DA N I E L T U C K E R DA T E : 02 / 0 5 / 2 0 2 5 SC A L E : N.T . S . SI E R R A F I N E C U S T O M H O M E S PL A N # : 28 2 9 CA N T E R B U R Y V I L L A G E LO T : 8 B L O C K : -- - - 27 2 7 N E W C A S T L E D R I V E GR A P E V I N E , TX 44 1 6 K E L L E R H I C K S R O A D FO R T W O R T H , T X 7 6 2 4 4 (8 1 7 ) 3 7 9 - 0 8 6 6 in f o @ n o r t e x f o u n d a t i o n . c o m NO R T E X F O U N D A T I O N D E S I G N S , I N C . JOB NUMBER 25-194196 TX FIRM REGISTRATION#: F-6417 FRAMING GENERAL NOTES 1. ENGINEERED DESIGN 1.1 THE ENGINEERED DESIGN OF THIS STRUCTURE IS INTENDED TO MEET THE FRAMING ENGINEERED DESIGN REQUIREMENTS AS ISSUED BY THE CITY OF 1.2 THE ENGINEERED DESIGN OF THIS STRUCTURE IS DESIGNED FOR A BASIC WIND SPEED OF 1.3 PER IRC R301.1.2 THE EXTENT OF THE ENGINEERED DESIGN "SHALL ONLY DEMONSTRATE COMPLIANCE OF THESE NONCONVENTIONAL ELEMENTS WITH OTHER APPLICABLE PROVISIONS AND SHALL BE COMPATIBLE WITH THE PERFORMANCE OF THE CONVENTIONAL FRAMED SYSTEMS." 1.4 ITEMS NOT COVERED ON THESE DRAWINGS SHALL MAINTAIN STRICT COMPLIANCE WITH THE I.R.C. 2. WOOD SPECIFICATIONS 2.1 ALL STUDS SHALL BE SPF STUD GRADE OR EQUIVALENT. 2.2 SILL PLATES SHALL BE PRESSURE TREATED #2 S.Y.P. 2.3 RAFTERS AND JOISTS SHALL BE #2 S.Y.P. WITH A MODULUS OF ELASTICITY, E=1,600,000 psi UNLESS NOTED OTHERWISE. 2.4 HEADERS AND BEAMS, WHEN SPECIFIED, SHALL HAVE A MINIMUM MODULUS OF ELASTICITY, E=1,800,000 psi, AND TABULATED BENDING STRESS, Fb=2400 psi, UNLESS NOTED OTHERWISE. 3. EXTERIOR WALL BRACING 3.1 THIS SHEET REPRESENTS THE EXTENT OF THE LATERAL BRACING WHICH NEEDS TO BE INSTALLED TO COMPLY WITH SECTION R602.10 OF THE IRC. THERE ARE AREAS WHICH DO NOT CONFORM TO THIS SECTION. ENGINEERED SOLUTIONS AS SHOWN ARE PROVIDED TO ENSURE ADEQUATE PERFORMANCE WITH THE SYSTEM. 3.2 ALL STRUCTURAL PANEL SHEATHING, LOCATED AS SHOWN ON THE PLAN, SHALL BE 7/16" THICK PLYWOOD OR OSB. PANELS SHALL BE SECURED TO FRAMING WITH 1 1/2" LONG, 16 GAUGE STAPLES OR 8d COMMONS SPACED AT 3" O.C. AROUND THE EDGE AND 6" O.C. IN THE FIELD. 3.3 A 2x HORIZONTAL BLOCKING MEMBER SHALL BE INSTALLED AT ALL HORIZONTAL JOISTS FOR STRUCTURAL PANEL WOOD SHEATHING. THE BRACING PLAN AS SHOWN ON THIS SHEET SHALL BE REFERRED TO FOR THE BRACING LOCATIONS. 3.4 IF SIMPSON STRONGWALLS ARE TO BE USED, CONSIDERATION SHALL BE GIVEN TO PLACING THE ORDER WITH APPROPRIATE LEAD TIME (POSSIBLY AS MUCH AS 2 WEEKS) AS ALL PRODUCTS MAY NOT BE IN STOCK. 3.5 WHEN DRILLING INTO THE SLAB FOR HOLDOWNS OR ANCHOR BOLTS, CARE SHOULD BE TAKEN TO AVOID DAMAGE OF POST-TENSIONED CABLES. LATERAL BRACING DETAILS PER INTERNATIONAL RESIDENTIAL CODE, EDITION 8" MAX. 14 " M I N . SI M P S O N C S 1 6 S STAGGERED 1ST FLOOR STUD 2ND FLOOR STUD @ EACH END OF PLYWOOD or OSB SHEAR WALL PANEL FULLY NAIL STRAPS TO 2ND FLOOR RIM JOIST or BLOCKING 2ND FLOOR FRAMING SI M P S O N C S 1 6 14 " M I N . S S S 2ND FLOOR PLYWOOD or OSB SUBFLOOR ELEVATION 1ST FLOOR TOP PLATE ELEVATION STRAP A TYPICAL FLOOR-TO-FLOOR SHEARWALL PANEL STRAP DETAIL SCALE: N.T.S SECTION A-A RIM JOIST or BLOCKING 7/16" PLYWOOD or OSB SHEAR PANEL 1ST FLOOR PLYWOOD or OSB SHEAR WALL PANEL (WHEN PRESENT) 2ND FLOOR PLYWOOD or OSB SHEAR WALL PANEL ADD 1ST FLOOR STUD AS REQUIRED WHEN STUD SPACING BELOW IS OFFSET FROM STUD SPACING ABOVE, or USE ALTERNATE STAGGERED STUD STRAP DETAIL. S 2ND FLOOR FRAMING SEE ALTERNATIVE STAGGERED STUD STRAP DETAIL S A S SI M P S O N C S 1 6 C O I L E D S T R A P ( O R E Q U A L ) . F I E L D C U T T O R E Q U I R E D L E N G T H . 14 " M I N . S 1ST FLOOR STUD WALL 2ND FLOOR FRAMING 14 " M I N . 2ND FLOOR PLYWOOD or OSB SUBFLOOR ELEVATION 1ST FLOOR TOP PLATE ELEVATION S 2ND FLOOR STUD WALL PLYWOOD or OSB SUBFLOOR EXTERIOR WALL CORNER or EDGE OF 2ND FLOOR OSB PANEL CLOSEST TO CORNER UNLESS NOTED OTHERWISE, FLOOR-TO-FLOOR SHEAR WALL PANEL STRAPS ARE REQUIRED AT EXTERIOR WALL CORNERS ONLY S ALTERNATIVE STAGGERED STUD STRAP DETAIL *(REF. TO WSWD-1 FOR WOOD STRONG WALL ALTERNATE WHERE MIN. WIDTHS CAN NOT BE ACHIEVED HORIZONTAL PANEL JOINTS, IF REQUIRED, SHALL OCCUR WITHIN 24" OF MID-HEIGHT. PROVIDE 2X BLOCKING w/ 16d SINKERS @ 3" O.C. ON EACH SIDE OF SEAM EXTEND HEADER ACROSS ALL OF THE JACK STUDS TOP PLATE ELEVATION 2-SIMPSON STHD10 (INSTALL BEFORE CONCRETE POUR) 16" MIN. FOR 8' HEIGHT 18" MIN. FOR 9' HEIGHT 20" MIN. FOR 10' HEIGHT MIN. ONE FULL-HEIGHT STUD. ADD ADDITIONAL FULL-HEIGHT STUDS AS SPACE PERMITS. 7/16" or OSB CRIPPLE STUDS AS REQUIRED (TYP.) TOP PLATE ELEVATION FASTEN 2X PLATE TO HEADER WITH 2 ROWS OF 16d SINKERS @ 3" O.C. DETAIL J BUILT-UP PORTAL FRAME SCALE: N.T.S OUTSIDE FACE OF WALL INSIDE FACE OF WALL ALTERNATIVE ATTACHEMENT TO FOUNDATION 7/16" PLYWOOD or OSB w/8d COMMON NAILS @ 6" O.C. AT PANEL EDGES AND @ 12" O.C. IN FIELD 2-SIMPSON MST27 STRAPS or EQUAL (TYP.) (2) MSTA30 = (1) MST27 1/2" DIA ANCHOR BOLT; DRILL AND INSTALL w/ SIMPSON SET EPOXY, 7" EMBEDMENT [ALTERNATIVELY, INSTALL 1/2" DIA. J-BOLT (7" EMBEDMENT) BEFORE CONCRETE POUR] NOTE: 1/2" ANCHOR BOLT IS NOT REQUIRED WHEN 2-SIMPSON HTT4'S ARE USED. 12" MIN STRAPS ACROSS HEADER TRANSITION (2)2x4 JACK STUDS EACH END (TYP.) KING STUD EACH END PROVIDE SOLID 2X BLOCKING BETWEEN HEADERS HEADER- SEE PLAN FOR BEAM SIZE (TYP.) BRACED WALL PANEL BETWEEN GARAGE DOORS TOP PLATE ELEVATION . 10 ' M A X . H E I G H T T O T O P O F H E A D E R 8d COMMON NAILS @ 3" O.C.E.W. THIS AREA 1/2" DIA ANCHOR BOLT; INSTALL w/ SIMPSON SET EPOXY, 7" EMBEDMENT (ALTERNATIVELY INSTALL 1/2" DIA. J-BOLT BEFORE CONCRETE POUR.) 2-SIMPSON HTT4 W/ 5/8" DIA ANCHOR BOLTS; INSTALL W/SIMPSON SET EPOXY, 10" EMBEDMENT (7" EMBEDMENT WHEN NO CURB IS PRESENT) 2-SIMPSON STHD10 (INSTALL BEFORE CONCRETE POUR) 1 #4 REBAR INSTALLED IN SHEAR CONE PER SIMPSON INSTALLATION REQUIREMENTS le HORIZONTAL PROJECTION 1 #4 REBAR INSTALLED IN SHEAR CONE PER SIMPSON INSTALLATION REQUIREMENTS **WHEN HEADER NOT CONTINUOUS NOTE: RED THERMO-PLY IS AN ALLOWABLE SUBSTITUTION FOR OSB/PLYWOOD SHEATHING. THE FASTENERS & ATTACHMENT PATTERN SHALL BE IN ACCORDANCE WITH TABLE ON GFD/1. SEE GFD/1 FOR ADDITIONAL INFORMATION. DTL / 2 DR A W N B Y : DA N I E L T U C K E R DA T E : 02 / 0 5 / 2 0 2 5 SC A L E : N.T . S . SI E R R A F I N E C U S T O M H O M E S PL A N # : 28 2 9 CA N T E R B U R Y V I L L A G E LO T : 8 B L O C K : -- - - 27 2 7 N E W C A S T L E D R I V E GR A P E V I N E , TX 44 1 6 K E L L E R H I C K S R O A D FO R T W O R T H , T X 7 6 2 4 4 (8 1 7 ) 3 7 9 - 0 8 6 6 in f o @ n o r t e x f o u n d a t i o n . c o m NO R T E X F O U N D A T I O N D E S I G N S , I N C . JOB NUMBER 25-194196 TX FIRM REGISTRATION#: F-6417 DTL / 3 3-SIMPSON SDS1/4x4.5 WOOD SCREWS INTO EACH SIDE OF CHIMNEY FRAME AT RAFTER AND CEILING PENETRATIONS. 7/16" PLYWOOD or OSB AROUND PERIMETER; NAIL WITH 10d COMMON NAILS AT 6" O.C., @ PANEL EDGES AND 12" O.C. AT INTERIOR SUPPORTS 2x4 CONNECTED WITH 10d COMMON NAIL AT 12" O.C. TYPICAL AT CORNERS "T" INTERSECTION POST CAP SEE SCHEDULE POST BASE SEE SCHEDULE 5/8" ANCHOR ROD INSTALLED WITH SIMPSON SET EPOXY (4" EMBEDMENT) POST BASE SEE SCHEDULE POST COLUMN HUC2xTF (x=DEPTH OF JOIST) "L" INTERSECTION POST CAP SEE SCHEDULE POST COLUMN BLOCKING CEILING JOISTS CHIMNEY FRAMING ELEVATION PERIMETER NAILING: 10d COMMON NAILS AT 6" O.C. INTERIOR SUPPORT NAILING: 10d COMMON NAILS AT 12" O.C. BLOCKING 7/16" PLYWOOD or OSB RAFTERS CHIMNEY FRAMING PLAN 2x4 BLOCK AT 4'-0" O.C. EACH SIDE 7/16" PLYWOOD OR OSB SHEATHING w/ 8d COMMON NAILS @ 6" O.C. @ PANEL EDGES AND @ 12" O.C. IN FIELD DBL 2x SOLID BLOCKING HIGH TOP PLATE ELEVATION (2) 1/2" DIA ANCHOR BOLTS, INSTALLED W/SIMPSON SET EPOXY (7" MIN EMBEDMENT) SIMPSON LSTA30 or EQUAL w/ 22-10d NAILS EXTEND SHEATHING 2 STUD SPACES (O.C.E.W.) STEEL LINTEL - SEE SCHEDULE SIMPSON MAS MUDSILL ANCHORS @ 5'-0" O.C. MAXIMUM ALONG EXTERIOR WALL LINE, WITHIN 12" OF WALL CORNERS, AND WITHIN 4" TO 12" OF SILL PLATE BUTT JOINTS. (INSTALL BEFORE CASTING THE SLAB) 1/2" DIA ANCHOR ROD (7" EMBEDMENT) @ 6'-0" O.C. MAXIMUM ALONG EXTERIOR WALL LINE, WITHIN 12" OF WALL CORNERS, AND WITHIN 4" TO 12" OF SILL PLATE BUTT JOINTS. DRILL AND INSTALL w/ SIMPSON SET EPOXY (ALTERNATIVELY, INSTALL J-BOLTS BEFORE CASTING THE SLAB) TOP OF CONCRETE ELEVATION TOP OF CONCRETE ELEVATION STUD BEYOND PRESSURE TREATED 2x SILL PLATE (#2 S.Y.P. or EQUAL) WASHER AND NUT REQ'D PRESSURE TREATED 2x SILL PLATE (#2 S.Y.P. or EQUAL) 1 1/2" DIA. THRU-BOLT @ 24" O.C., TYP. SEE PLAN FOR HEADER SIZE STUD BEYOND (2)2x4 EACH CORNER OPENING BELOW 3" M I N 1 1 / 2 " M I N ARCHITECTURAL FASCIA NOTES: 1.USE SIMPSON Z-MAX FINISH or USP EQUIVALENT FOR POST CONNECTORS WITH PERMANENT EXTERIOR EXPOSURE. 2.USE PRESSURE TREATED LUMBER WHEN WOOD IS PERMANENTLY EXPOSED TO THE ENVIRONMENT. SECTION Y-Y X X Y Y CHIMNEY FRAMING PLAN SECTION X-X TYPICAL CHIMNEY WIND BRACING DETAIL SCALE: N.T.S SCALE: N.T.S SCALE: N.T.S TYPICAL LEDGER ANGLE SUPPORT DETAIL SCALE: N.T.S SEE SHEET NOTE 2 ANCHOR BOLTS 2 MUDSILL ANCHORS TYPICAL EXTERIOR WALL SILL PLATE ATTACHMENT DETAIL (USE METHOD 1 or 2 ) SCALE: N.T.S LOW TOP PLATE ELEVATION TYPICAL TOP PLATE ELEVATION CHANGE DETAIL SCALE: N.T.S SEE SHEET NOTE 2 TYPICAL EXTERIOR POST ATTACHMENT DETAIL SCALE: N.T.S POST COLUMN CONNECTION SCHEDULE (SIMPSON) POST CAPS POST BASEPOST SIZE 4 x 4 6 x 6 8 x 8 10 x 10 12 x 12 "L" INTERSECTION LCE4 (EACH SIDE) LCE4 (EACH SIDE) BC8 LCE4 (EACH SIDE) LCE4 (EACH SIDE) "T" INTERSECTION AC4 (EACH SIDE) AC6 (EACH SIDE) BC8 (2)LCE4 (EACH SIDE) (2)LCE4 (EACH SIDE) ABU44 ABU66 ABU88 CB1212 CB1010 PRE-APPROVED STRUCTURAL CONNECTORS CROSS REFERENCE TABLE SIMPSON STRONG-TIE A34 ABU44 ABU66 AC4 AC6 CS16 H3 H4 HGA10 HHUS410 HHAS5.50/10 HTT16 HTT22 HU210-3 HU212-3 HU48 LSTA24 LSTA30 USP STRUCTURAL CONNECTORS SIMPSON STRONG-TIE USP STRUCTURAL CONNECTORS MP34 PAU44 PAU66 PBS44 PBS66 RS150 RT3 RT3 HGA10 THD410 THD610 HTT16 HTT22 HU210-3 HU212-3 HU48 LSTA24 LSTA30 LTS12 LTP4 LUS26 LUS26-2 LUS26-3 LUS28 LUS28-2 LUS28-3 LUS210 LUS210-2 LUS210-3 MAS MST27 SPH4 SPH6 U410 U414 LTS12 MP4F JUS26 JUS26-2 JUS26-3 JUS28 JUS28-2 JUS28-3 JUS210 JUS210-2 JUS210-3 FA3 KST227 SPTH4 SPTH6 SUH410 SUH414 GENERAL FRAMING DETAILS BUILT UP POSTS # OF BOLTSPOST SIZE TREATED SILL PLATE SIZE WOOD SPEICES (3) 2x4's (4) 2x6's (6) 2x8's (6) 2x10's (8) 2x12's 2x4 x 4 1 2" 2x6 x 6" 2x8 x 9" 2x10 x 9" 2x12 x 12" SYP #2 SYP #2 SYP #2 SYP #2 SYP #2 1 1 2 2 3 DR A W N B Y : DA N I E L T U C K E R DA T E : 02 / 0 5 / 2 0 2 5 SC A L E : N.T . S . SI E R R A F I N E C U S T O M H O M E S PL A N # : 28 2 9 CA N T E R B U R Y V I L L A G E LO T : 8 B L O C K : -- - - 27 2 7 N E W C A S T L E D R I V E GR A P E V I N E , TX 44 1 6 K E L L E R H I C K S R O A D FO R T W O R T H , T X 7 6 2 4 4 (8 1 7 ) 3 7 9 - 0 8 6 6 in f o @ n o r t e x f o u n d a t i o n . c o m NO R T E X F O U N D A T I O N D E S I G N S , I N C . JOB NUMBER 25-194196 TX FIRM REGISTRATION#: F-6417 DOUBLE-PLY CEILING BEAM SUPPORT (OPTIONAL) A SIMPSON HGA10. CEILING BEAM NUMBER OF ROOF RAFTER TAILS TO MATCH NUMBER OF PLIES IN CEILING BEAM RAFTER TAILS ALTERNATIVE DOUBLE-PLY CEILING BEAM SUPPORT CEILING BEAM RAFTER TAILS TRIPLE-PLY CEILING BEAM SUPPORT CEILING BEAM RAFTER TAILS MA X U N B R A C E D LE N G T H ( R E : P L A N ) 2x4 COLLAR TIES'S @ 48" O.C. (LOCATE IN UPPER 1/3 OF ROOF RAFTER) NAIL HORIZONTAL LEG OF STONGBACK TO EACH CEILING JOIST w/ (2)8d COMMONS CONTINUOUS (2)2x4 OR (2)2x6 STRONGBACK @ 48" O.C. (OPTIONAL) SIMPSON HGA10 @ EACH RAFTER MINIMUM (6)10d COMMON NAILS PER PLY MINIMUM DOUBLE ROOF RAFTER [EXCEPT USE TRIPLE ROOF RAFTER FOR TRIPLE 2x10 OR LARGER BEAMS] NAIL VERTICAL LEG OF STONGBACK TO RAFTER w/ (4)10d COMMONS BLOCKING AS REQUIRED CEILING JOISTS CEILING JOISTS RAFTERSRAFTERS (OPTIONAL) ONE SIMPSON H3 or EQUAL AT 48" O.C. BLOCKING AS REQUIRED RAFTERS BRACES @ 4'-0" O.C. NAIL HORIZONTAL LEG OF STRONGBACK TO EACH CEILING JOIST w/ (2)8d COMMONSNAIL VERTICAL LEG OF STRONGBACK TO RAFTER w/ (4)10d COMMONS )( (OPTIONAL) ONE SIMPSON HGA10 @ EACH RAFTER. CONTINUOUS (2)2x4 or (2)2x6 STRONGBACK @ 48" O.C.() ROOF RAFTER 4-10d COMMON NAILS4-10d COMMON NAILS ROOF RIDGE BEAM or RIDGE PLATE 8-10d COMMON NAILS FROM CEILING JOIST TO RAFTER FOR VAULTED CEILINGS ONLY INSTALL ONE RAFTER TAIL UNDER CEILING JOIST > 4 5 NAIL FLANGE TO WEB w/10d COMMONS @ 9" O.C. T-BRACE WEB o SECTION A-A PURLIN TO MATCH RAFTER SIZE T-BRACE FLANGE NOTE: NOTCH IN ROOF RAFTER SHOULD NOT EXCEED 1/4 OF THE RAFTER DEPTH 4-10d COMMON NAILS FROM CEILING JOIST TO RAFTER (OPTIONAL) ONE SIMPSON H3 or EQUAL AT 48" O.C. COLLAR TIE CONNECTION DETAIL SCALE: N.T.S VAULTED CEILING DETAIL SCALE: N.T.S RAFTER ATTACHMENT TO TOP PLATE DETAIL SCALE: N.T.S T-BRACE PURLIN SUPPORT SCALE: N.T.SCEILING JOISTS PERPENDICULAR TO RAFTERS SCALE: N.T.S VAULTED CEILING w/ CEILING JOIST PERPENDICULAR TO RAFTERS SCALE: N.T.S ROOF SUPPORT JOIST DETAIL SCALE: N.T.S GENERAL FRAMING DETAILS IF RAFTER SIZE IS BIGGER THAN 2x6, APPLY SHEETROCK NAILER BETWEEN RAFTERS IF RAFTER SIZE IS BIGGER THAN 2x6, APPLY SHEETROCK NAILER BETWEEN RAFTERS IF RAFTER SIZE IS BIGGER THAN 2x6, APPLY SHEETROCK NAILER BETWEEN RAFTERS 2x4 HEIGHT REQUIREMENTS SECTION 1-10 FT.2x4 "T" BRACING 2x4 2x4 2x6 2x6 2x8 11-20 FT. 21-30 FT. 2x6/2x4 "T" BRACING 2x8/2x6 "T" BRACING "T" BRACING SCHEDULE NOTES 1.REFER TO SHEET DTL-1 FOR FRAMING GENERAL NOTES. 2.RAFTERS, RIDGES, HIPS AND VALLEYS SHALL BE #2 S.Y.P. or EQUAL. 3.RIDGE, HIP, VALLEY, AND PURLIN LOADS SHALL BE DISTRIBUTED TO WALLS or BEAMS BELOW BY "T" BRACES. REFER TO "T-BRACE SCHEDULE" ON THIS SHEET FOR SIZING. THE "T" BRACES SHALL BE INSTALLED AT AN ANGLE GREATER THAN 45 DEGREES WITH THE HORIZONTAL. BRACE PURLINS AT 4'-0" O.C. MAX. 4.RAFTER SPANS EXCEEDING I.R.C. SPAN CHART (LISTED ON SHEET FR-3) WITH THE HORIZONTAL DISTANCE SHALL BE BRACED WITH A PURLIN MATCHING THE RAFTER SIZE IT IS BRACING. 5.THE ROOF SUPPORT FRAMING IS DESIGNED TO SUPPORT AN ASPHALT or COMPOSITION SHINGLE ROOF. VARIATIONS FROM THIS TYPE OF ROOF COVERING SYSTEM MUST BE BROUGHT TO THE ATTENTION OF THE FRAMING ENGINEER FOR RE-DESIGN. A DTL / 4 DR A W N B Y : DA N I E L T U C K E R DA T E : 02 / 0 5 / 2 0 2 5 SC A L E : N.T . S . SI E R R A F I N E C U S T O M H O M E S PL A N # : 28 2 9 CA N T E R B U R Y V I L L A G E LO T : 8 B L O C K : -- - - 27 2 7 N E W C A S T L E D R I V E GR A P E V I N E , TX 44 1 6 K E L L E R H I C K S R O A D FO R T W O R T H , T X 7 6 2 4 4 (8 1 7 ) 3 7 9 - 0 8 6 6 in f o @ n o r t e x f o u n d a t i o n . c o m NO R T E X F O U N D A T I O N D E S I G N S , I N C . JOB NUMBER 25-194196 TX FIRM REGISTRATION#: F-6417 TYPICAL DETAIL - BRICK ON WOOD RAFTER SUPPORT AT ROOF RIDGE BEAM or OTHER ROOF FRAMING MEMBER OVERALL SPAN (=EFFECTIVE SPAN WHEN NO ADDITIONAL T-BRACES PROVIDED) ARCH CLEAR SPAN LESS THAN 6'-0": 1.STEEL LINTELS ARE OPTIONAL. FOR SELF-SUPPORTING MASONRY: 2.USE TYPE N MORTAR CEMENT. PROPER SHORING AND AMPLE MORTAR SET TIME ARE IMPERATIVE. 3.EXPANSION JOINTS SHALL NOT OCCUR OVER THE ARCH OR WITHIN 5' OF EITHER SIDE OF THE ARCH OPENING. 4.ATTACH 7/16" OSB TO THE WOOD FRAME BACKING BEHIND THE ARCH AND CONTINUE A MINIMUM OF 3' ON EITHER SIDE OF THE ARCH OPENING. USE 8d COMMON NAILS @ 6" O.C. @ PANEL EDGES AND @ 12" O.C. IN THE FIELD. WALL STUD NAIL EACH END OF EACH PLY OF BLOCKING TO JOIST WITH MINIMUM (3) 8d COMMON TOE NAILS 5/8" DIAM. LAG SCREWS (3 1/2" LONG) @ 32" O.C. ATTACH INTERIOR PLY TO EACH STUD WITH MINIMUM 3-#10 WOOD SCREWS (4" MIN. LENGTH); NAIL EACH ADDITIONAL PLY WITH 3-10d COMMON NAILS @ EACH STUD PRESSURE TREATED BRICK SUPPORT BEAM ADJACENT RAFTER or JOIST BRICK OR STONE WALL STUD 5/8" DIAM. LAG SCREWS (3 1/2" LONG) @ 32" O.C. BRICK VENEER BRICK SUPPORT BEAM SPAN BR I C K HE I G H T TYPICAL WALL SUPPORT BELOW PRESSURE TREATED BRICK SUPPORT BEAM-SEE SCHEDULE STUD WALL BEYOND NOT SHOWN FOR CLARITY NAIL EACH PLY TOGETHER w/ 2 ROWS OF 16d COMMON NAILS @ 12" O.C. RAFTER or JOIST PRESSURE TREATED (3)2x4 BRICK SUPPPORT BLOCKING BETWEEN JOISTS BRICK or STONE FLOOR FRAMING OR HEADER, IF APPLICABLE (SEE PLAN) ROOF SLOPE (SEE ARCHITECTURAL PLANS) ADDITIONAL T-BRACE AS REQUIRED TO REDUCE EFFECTIVE SPAN (SUPPORTED BY STUD WALL OR BEAM BELOW) MIN. DBL. RAFTER OPPOSITE BRICK ON WOOD SUPPORT BEAM T-BRACE SUPPORTED BY STUD WALL OR BEAM BELOW EFFECTIVE SPAN SCALE: N.T.S PRESSURE TREATED BRICK SUPPORT BEAM- SEE PLAN A A TYPICAL EACH END OF LINTEL RISE-SEE ARCH PLAN ARCH CLEAR SPAN OF 6'-0" OR MORE: 1.STEEL LINTELS ARE REQUIRED. SEE DETAIL BELOW. 2.ATTACH LAG BOLTS TO SOLID WOOD HEADER OR BLOCKING 3.LINTEL SHALL BE PAINTED AND FLASHED (NORTEX RECOMMENDS 40-MIL. RUBBERIZED ASPHALT FLASHING) 1/2"-DIAM LAG BOLTS (4" LONG) @ 24" O.C. TYP. CLEAR SPAN A36 STEEL NOTES: 1.REFER TO SHEET DTL-1 FOR GENERAL NOTES. 2.ALL FASTENERS (INCLUDING NAILS, SCREWS, BOLTS, AND THREADED RODS) IN CONTACT WITH PRESSURE TREATED WOOD SHALL BE HOT-DIPPED GALVANIZED (NORTEX RECOMMENDS G185 GALVANIZING). ALL SIMPSON CONNECTORS IN CONTACT WITH PRESSURE TREATED WOOD SHALL HAVE THE Z-MAX FINISH. 3.BRICK ON WOOD SUPPORT BEAMS ARE SIZED TO MEET L/600 DEFLECTION CRITERIA. 4.ALL BRICK SUPPORT BEAMS SHALL BE #2 S.Y.P. or EQUAL. LOW ROOF FRAMING MIN. PRESSURE TREATED (3)2x6 ATTACH EACH ADDITIONAL PLY AT EACH STUD W/MIN. (3)10d COMMON NAILS ATTACH INSIDE PLY AT EACH STUD w/(3)5/8"-DIAM LAG SCREWS (5" LONG) WALL SUPPORT BELOW STUD WALL BEYOND NOT SHOWN FOR CLARITY BRICK VENEER *= ENGINEERED BEAM REQUIRED MIN. BEARING LENGTH BRICK ON WOOD - PARALLEL FRAMING SUPPORT BRICK HEIGHT ABOVE BEAMSPAN2'-0"4'-0"6'-0"8'-0"10'-0" (3)2x6's (3)2x6's (3)2x8's (3)2x10's (3)2x12's (3)2x6's (3)2x6's (3)2x8's (3)2x10's (3)2x12's (3)2x6's (3)2x8's (3)2x10's (3)2x12's * (3)2x6's (3)2x8's (3)2x10's (3)2x12's (3)2x6's (3)2x8's (3)2x10's (3)2x12's ≤ 4'-0" 4'-0" < SPAN ≤ 6'-0" 6'-1" < SPAN ≤ 8'-0" 8'-1" < SPAN ≤ 10'-0" 10'-1" < SPAN ≤ 12'-0" A A TYPICAL DETAIL - BRICK ON WOOD BRICK VENEER PARALLEL TO FRAMING SCALE: N.T.S SECTION A-A BEAM, IF APPLICABLE (SEE PLAN) STUD WALL, IF APPLICABLE (SEE PLAN) TYPICAL DETAIL - BRICK ON WOOD BRICK VENEER PERPENDICULAR TO FRAMING SCALE: N.T.S BRICK or STONEWALL STUD 5/8" DIAM. LAG SCREWS (3 1/2" LONG) @ 32" O.C. STEEL LINTEL, PAINTED AND FLASHED- SEE CHART TYPICAL BRICK ON WOOD SUPPORT @ LOW ROOF SCALE: N.T.S MIN. BEARING LENGTH ARCH CLEAR SPAN SPANS ≤ 6'-0' 6'-0" < SPAN ≤ 12'-0' MINIMUM LINTEL SIZE L3 1/2 x 3 1/2 x 1/4 L6 x 4 x 1/2 MINIMUM BEARING LENGTH 4 INCHES 4 INCHES TYPICAL BRICK ARCH LINTEL BRICK ON WOOD DETAILS SCALE: N.T.S ** STEEL LINTEL, PAINTED AND FLASHED- SEE CHART STEEL LINTEL, PAINTED AND FLASHED- SEE CHART GENERAL FRAMING DETAILS DTL / 5 2021 DR A W N B Y : DA N I E L T U C K E R DA T E : 02 / 0 5 / 2 0 2 5 SC A L E : N.T . S . SI E R R A F I N E C U S T O M H O M E S PL A N # : 28 2 9 CA N T E R B U R Y V I L L A G E LO T : 8 B L O C K : -- - - 27 2 7 N E W C A S T L E D R I V E GR A P E V I N E , TX 44 1 6 K E L L E R H I C K S R O A D FO R T W O R T H , T X 7 6 2 4 4 (8 1 7 ) 3 7 9 - 0 8 6 6 in f o @ n o r t e x f o u n d a t i o n . c o m NO R T E X F O U N D A T I O N D E S I G N S , I N C . JOB NUMBER 25-194196 TX FIRM REGISTRATION#: F-6417 GFD / 1 NOTES: 1.VERIFY THAT ENOUGH WALL SPACE IS AVAILABLE FOR OSB PANEL SUBSTITUTIONS 2.THE HEIGHT-TO-LENGTH RATIO OF THESE PANELS SHALL NEVER EXCEED 2 TO 1 3.STUD SPACING SHALL NOT EXCEED 16" O.C. 4.PANEL EDGES MAY BE BUTTED or LAPPED 3/4"MINIMUM. 5.ALL VERTICAL PANEL EDGES SHALL OCCUR OVER STUDS. 6.ALL HORIZONTAL PANEL EDGES SHALL BE BLOCKED WITH 2x LUMBER TABLE "A" - INSTALLATION SCHEDULE FASTENERS SPACING PANEL EDGE IN FIELD 3" O.C.6" O.C. 3" O.C.6" O.C. 3" O.C.6" O.C. 3" O.C.6" O.C. 3" O.C.6" O.C. TYPE 7/16" CROWN x 1-1/4" LEG, No. 16 GAUGE GALVANIZED STEEL STAPLES or No. 11 GAUGE, 1-1/4" GALVANIZED STEEL ROOFING NAILS SAME AS ABOVE SAME AS ABOVE SAME AS ABOVE 7/16" CROWN x 1-1/2" LEG, No. 16 GAUGE GALVANIZED STEEL STAPLES or No. 11 GAUGE, 1-1/2" GALVANIZED STEEL ROOFING NAILS LABEL RED RED RED BLUE N / A SHEATHING BRAND PRODUCT ENERGY BRACE THERMO-PLY STAR R STRUC THERMO-PLY FIBER BRACE 0.106" STRUCTURAL BRACE 0.113" STRUCTURAL GRADE (STORM BRACE) SHEATHING 0.625" 0.137" SUPER STRENGTH SHEATHING 0.500" STRUCTURAL TABLE "B" - MINIMUM LENGTH OF PANEL FOR VARIOUS PLATE HEIGHTS SHEATHING BRAND PRODUCT LABEL TOP PLATE HEIGHT ABOVE FLOOR MINIMUM LENGTH OF PANEL ENERGY BRACE THERMO-PLY STAR R STRUC THERMO-PLY FIBER BRACE DENS GLASS 0.106" STRUCTURAL BRACE 0.113" STRUCTURAL GRADE (STORM BRACE) SHEATHING 0.625" 0.137" SUPER STRENGTH SHEATHING 0.500" STRUCTURAL 0.500" STRUCTURAL MOLD RESTART RED RED RED BLUE N / A SILVER H ≤ 10' 10' < H ≤ 12' 12' < H ≤ 14' H ≤ 10' 10' < H ≤ 12' 12' < H ≤ 14' H ≤ 10' 10' < H ≤ 12' 12' < H ≤ 14' H ≤ 10' 10' < H ≤ 12' 12' < H ≤ 14' H ≤ 10' 10' < H ≤ 12' 12' < H ≤ 14' H ≤ 10' 10' < H ≤ 12' 12' < H ≤ 14' 7'-6" 9'-0" 9'-0" 7'-6" 9'-0" 9'-0" 7'-6" 9'-0" 9'-0" 7'-6" 9'-0" 9'-0" 7'-6" 9'-0" 9'-0" 5'-0" 6'-0" 7'-0" NOTES: A. STEEL ANGLE SIZES ARE BASED ON L/600 DEFLECTION CRITERIA B. REFER TO PLAN FOR AREAS WITH HIGHER CLEAR SPAN THAN 17' C. CHART NOT APPLICABLE FOR GARAGE AREAS (SEE PLAN) D. GABLE AREAS NOT INCLUDED (SEE PLAN) NOTES: 1.REFER TO SHEET DTL-1 FOR GENERAL NOTES. 2.ALL FASTENERS (INCLUDING NAILS, SCREWS, BOLTS, AND THREADED RODS) IN CONTACT WITH PRESSURE TREATED WOOD SHALL BE HOT-DIPPED GALVANIZED (NORTEX RECOMMENDS G185 GALVANIZING). ALL SIMPSON CONNECTORS IN CONTACT WITH PRESSURE TREATED WOOD SHALL HAVE THE Z-MAX FINISH. STEEL ANGLE PER TABLE STEEL LINTEL SCHEDULE HEIGHT OF VENEER 3 1/2 x 3 1/2 x 1/4 LINTEL SIZE HE I G H T O F V E N E E R 4 x 3 1/2 x 1/4 5 x 3 1/2 x 3/8 6 x 4 x 3/8 7 x 4 x 1/2 8 x 4 x1/2 21 12 6 3 2 1 15 10 5 3 2 1 CLEAR SPAN HEIGHT OF STONE 3 1/2 x 3 1/2 x 1/4 LINTEL SIZE 4 x 3 1/2 x 1/4 5 x 3 1/2 x 3/8 6 x 4 x 3/8 7 x 4 x 1/2 8 x 4 x1/2 HEIGHT OF BRICK 22 15 9 6 4 3 2 1 22 16 11 7 5 4 3 2 2 1 22 15 11 8 6 5 4 3 2 2 22 16 12 9 7 6 4 4 3 32 18 10 5 3 2 23 15 8 5 3 2 23 14 9 6 5 3 2 24 16 11 8 6 5 3 3 2 23 17 12 9 7 6 5 4 3 24 18 14 11 9 7 6 5 1 1 2 1 2 1 3 4 5 6 7 8 9 10 11 12 13 14 15 16 17 CLEAR SPAN (FEET) STONE = 60 LBS. / FT. SQUARED 3 4 5 6 7 8 9 10 11 12 13 14 15 16 17 CLEAR SPAN (FEET) BRICK = 40 LBS. / FT. SQUARED HEADER LOCATION INTERIOR & EXTERIOR WITH ROOF AND CEILING EXTERIOR WITH (1) FLOOR ABOVE INTERIOR WITH (1) FLOOR ABOVE SIZE (2)2x6's (2)2x8's EXTERIOR WITH (1) CLEAR SPAN FLOOR ABOVE (2)2x10's (2)2x12's SPAN # OF JACK STUDS 4'-2" 5'-4" 6'-6" 7'-6" 1 2 2 2 HEADER SCHEDULE SIZE (2)2x6's (2)2x8's (2)2x10's (2)2x12's SPAN # OF JACK STUDS 3'-7" 4'-6" 5'-6" 6'-5" 2 2 2 2 SIZE (2)2x6's (2)2x8's (2)2x10's (2)2x12's SPAN # OF JACK STUDS 3'-6" 4'-5" 5'-5" 6'-3" 1 2 2 2 SIZE (2)2x6's (2)2x8's (2)2x10's (2)2x12's SPAN # OF JACK STUDS 3'-0" 3'-10" 4'-8" 5'-5" 2 2 2 3 HEADER LOCATION HEADER LOCATION HEADER LOCATION NOTE: 1. ANY HEADER SPANS AND SIZES NOT COVERED ABOVE TO BE NOTED ON PLAN 2. SIZES AND SPANS BASED ON #2 S.Y.P. (IF OTHER, SEE PLAN) 3. FASTEN PLYS TOGETHER WITH 16d COMMON NAILS @ 16" O.C. ALONG EACH EDGE 4. ANY HEADERS FALLING UNDER A FLOOR SYSTEM NOT DESIGNED BY NORTEX, SHALL BE DESIGNED AND SIZED BY FLOOR SYSTEM MANUFACTURER ref. I.R.C. ® TABLES R602.7(1),R602.7(2) & R602.7(3) 1'-6" MAX. BEAM LENGTH DOUBLE L4x4x1/4 (A36 STEEL) w/ (6) 1/2"-DIAM. BOLTS 2" 2" 2x2 LEDGER INSTALL WASHERS @ EACH BOLT MINIMUM (3)10d COMMON NAILS UNDER EACH DIAGONAL STRUT 2x2 LEDGER W/ 10d COMMON NAILS @ 4" O.C. B (2)2x4 KICKER BRACE @ 18" O.C. ATTACH TO BEAM AND ADJACENT I-JOIST (NOT SHOWN) (2)2x8 @ 18" O.C. 3/4" OSB SUBFLOORB (2-PLY) ENGINEERED BEAM [MATCH HEIGHT OF I-JOIST FRAMING] 3/4" OSB SUBFLOOR FURR OUT LEDGE AS REQUIRED (2)2x8 POSITIONED TIGHT AGAINST BEAM 2x4 STRUT EACH SIDE. ATTACH W/ (4) 10d COMMON NAILS. SECTION B-B TYPICAL CANTILEVERED LEDGE FRAMING DETAIL SCALE: N.T.S SCALE: N.T.S SIMPSON HANGER SCHEDULE FOR MULTIPLE-PLY BEAMS and CEILING JOISTS (TYPICAL UNLESS NOTED OTHERWISE ON PLANS) MEMBER SIZE 2x6 (2)2x6 (3)2x6 2x8 (2)2x8 (3)2x8 2x10 (2)2x10 (3)2x10 FACE MOUNT TOP FLANGE LUS26 JB26 LUS26-2 HUS26-2TF HU26-3 N / A LUS26 JB28 HUS28-2 HUS28-2TF HU26-3 LUS28 LUS210-2 HU210-3 HU210-3TF N / A HUS210-2TF JB210 2x12 (2)2x12 (3)2x12 LUS210 LUS210-2 HU212-3 JB212 HUS212-2TF HU212-3TF NOTES: 1. SCHEDULE BASED ON NO POINT LOADS APPLIED TO BEAMS OR JOISTS. 2. SPECIALITY BEAM (LVL's, LSL's, PSL's, etc.) HANGERS WILL BE CALLED OUT ON THE PLAN. 3. REFER TO SIMPSON CATALOG FOR INSTALLATION GUIDELINES. 4. HANGER SCHEDULE BASED ON THE USE OF S.Y.P. LUMBER.GENERAL FRAMING DETAILS ALLOWABLE SHEAR WALL OSB OR PLYWOOD PANEL SUBSTITUTIONS DR A W N B Y : DA N I E L T U C K E R DA T E : 02 / 0 5 / 2 0 2 5 SC A L E : N.T . S . SI E R R A F I N E C U S T O M H O M E S PL A N # : 28 2 9 CA N T E R B U R Y V I L L A G E LO T : 8 B L O C K : -- - - 27 2 7 N E W C A S T L E D R I V E GR A P E V I N E , TX 44 1 6 K E L L E R H I C K S R O A D FO R T W O R T H , T X 7 6 2 4 4 (8 1 7 ) 3 7 9 - 0 8 6 6 in f o @ n o r t e x f o u n d a t i o n . c o m NO R T E X F O U N D A T I O N D E S I G N S , I N C . JOB NUMBER 25-194196 TX FIRM REGISTRATION#: F-6417 INTERIOR BRACING DETAILS NOTE: USE A METALLISCANNER TO LOCATE EXISTING CABLES TYPICAL DOOR OPENING (WHEN PRESENT) TOP PLATE ELEVATION REFER TO LATERAL BRACING PLAN FOR EXTENT OF SHEATHING REQUIREDSHEATH WALL AREAS ABOVE, BELOW, AND ADJACENT TO OPENINGS WITH 1/2" GYPSUM SHEATHING ON BOTH SIDES. 2x BLOCKING SHALL BE INSTALLED AT ALL HORIZONTAL PANEL JOINTS, AND VERTICAL PANEL JOINTS SHALL OCCUR OVER STUDS. USE 1/2" GALV. ROOFING NAIL OR STAPLE x 1 5/8" LONG; OR 1 5/8" SCREWS TYPE W OR S AT 7" O.C. FOR EDGE AND FIELD. OR LET-IN BRACE @ BOTH ENDS OF WALL NOTE: THE ELEVATION SHOWN IS FOR ILLUSTRATIVE PURPOSES ONLY AND MAY DIFFER FROM ACTUAL CONDITIONS DETAIL IL FIRST FLOOR INTERIOR SHEATHING DETAIL SCALE: N.T.S TYPICAL HALLWAY OR ROOM (WHEN PRESENT) 4" MI N . 3,000 PSI CONCRETE TOP PLATE ELEVATION 1x4 NOTCHED INTO STUDS. NOTCH MUST BEAR ON DIAGONAL or BE REINFORCED WITH METAL STRAP. OR45 DEGREES (MIN.) TO 60 DEGREES (MAX.) INSTALL SIMPSON 1/2" x 5" LG. TITEN HD (THD50500H) WITHIN 6'-0" OF BOTH END OF WALL PER MFG.'S INSTRUCTIONS TYPICAL DOOR OPENING (WHEN PRESENT) TOP PLATE ELEVATION REFER TO LATERAL BRACING PLAN FOR EXTENT OF SHEATHING REQUIREDSHEATH WALL AREAS ABOVE, BELOW, AND ADJACENT TO OPENINGS WITH 1/2" GYPSUM SHEATHING ON BOTH SIDES. 2x BLOCKING SHALL BE INSTALLED AT ALL HORIZONTAL PANEL JOINTS, AND VERTICAL PANEL JOINTS SHALL OCCUR OVER STUDS. USE 1/2" GALV. ROOFING NAIL OR STAPLE x 1 5/8" LONG; OR 1 5/8" SCREWS TYPE W OR S AT 7" O.C. FOR EDGE AND FIELD. OR LET-IN BRACE @ BOTH ENDS OF WALL NOTE: THE ELEVATION SHOWN IS FOR ILLUSTRATIVE PURPOSES ONLY AND MAY DIFFER FROM ACTUAL CONDITIONS DETAIL IU SECOND FLOOR INTERIOR SHEATHING DETAIL SCALE: N.T.S TYPICAL HALLWAY OR ROOM (WHEN PRESENT) FLOOR JOIST RED T-PLY IS AN ALLOWABLE SUBSTITUTION FOR GYPSUM SHEATHING. SEE GFD/1 FOR NAILING PATTERN & OTHER REQUIREMENTS. PROVIDE BLOCKING @ ALL HORIZONTAL JOINTS. TOP PLATE ELEVATION 1x4 NOTCHED INTO STUDS. NOTCH MUST BEAR ON DIAGONAL or BE REINFORCED WITH METAL STRAP. OR45 DEGREES (MIN.) TO 60 DEGREES (MAX.) RED T-PLY IS AN ALLOWABLE SUBSTITUTION FOR GYPSUM SHEATHING. SEE GFD/1 FOR NAILING PATTERN & OTHER REQUIREMENTS. PROVIDE BLOCKING @ ALL HORIZONTAL JOINTS. IBD / 1 Generated by REScheck-Web Software Compliance Certificate Project Newcastle Addition/Remodel Energy Code:2015 IECC Location:Grapevine, Texas Construction Type:Single-family Project Type:Addition Orientation:Bldg. faces 315 deg. from North Climate Zone:3 (2683 HDD) Permit Date: Construction Site: 2727 Newcastle Dr. Grapevine, TX 76051 Owner/Agent:Designer/Contractor: Sierra Fine Custom Homes Permit Number: false false Has Battery:false false Has Heat Pump:false All Electric Is Renewable Has Charger Project SubType:None Compliance: Passes using UA trade-off 3.2% Better Than Code Maximum UA:222 Your UA:215 The % Better or Worse Than Code Index reflects how close to compliance the house is based on code trade-off rules. It DOES NOT provide an estimate of energy use or cost relative to a minimum-code home. Compliance:Maximum SHGC:0.25 Your SHGC:0.21 Slab-on-grade tradeoffs are no longer considered in the UA or performance compliance path in REScheck. Each slab-on-grade assembly in the specified climate zone must meet the minimum energy code insulation R-value and depth requirements. Envelope Assemblies Assembly Gross Area or Perimeter Cavity R-Value Cont. R-Value Prop. U-Factor Req. U-Factor Prop. UA Req. UA Ceiling: Cathedral Ceiling 1,171 0.0 22.0 0.042 0.030 49 35 Front Wall: Wood Frame, 16" o.c. Orientation: Front 487 0.0 13.5 0.056 0.060 21 23 Window: Metal Frame SHGC: 0.21 Orientation: Front 106 0.290 0.350 31 37 Left Wall: Wood Frame, 16" o.c. Orientation: Left side 389 0.0 13.5 0.056 0.060 22 23 Rear Wall: Wood Frame, 16" o.c. Orientation: Back 487 0.0 13.5 0.056 0.060 22 23 Window 1: Metal Frame SHGC: 0.21 Orientation: Back 99 0.290 0.350 29 35 Right Wall: Wood Frame, 16" o.c. Orientation: Right side 509 0.0 13.5 0.056 0.060 26 27 Project Title: Newcastle Addition/Remodel Data filename:Page 1 of 2 01/24/25Report date: Assembly Gross Area or Perimeter Cavity R-Value Cont. R-Value Prop. U-Factor Req. U-Factor Prop. UA Req. UA Window 2: Metal Frame SHGC: 0.21 Orientation: Right side 53 0.290 0.350 15 19 Floor: Slab-On-Grade (Unheated) Insulation depth: 0.0' Insulation position: No Insulation 56 0.0 1.042 1.042 0 0 Name - Title Signature Date Compliance Statement: The proposed building design described here is consistent with the building plans, specifications, and other calculations submitted with the permit application. The proposed building has been designed to meet the 2015 IECC requirements in REScheck Version : REScheck-Web and to comply with the mandatory requirements listed in the REScheck Inspection Checklist. Project Title: Newcastle Addition/Remodel Data filename:Page 2 of 2 01/24/25Report date: Martin Caraway - Plans Examiner 1/24/2025