HomeMy WebLinkAboutSFRA2025-000662 7 .. . . ........ . . ..... . RECEIVED: 2/21/2025 25-000662 4345 WOODGLEN DRIVE DATE OF ISSUANCE: SOLAR PANELS PERMIT q BUILDING PERMIT APPLICATION ELECTRONIC REVIEW (PLEASE PRINT LEGIBLY — COMPLETE ENTIRE FORM) JOB ADDRESS: 4345 Woodglen Dr. Grapvine, TX 76051 SUITE # LOT: BLOCK: SUBDIVISION: BUILDING.CONTRACTOR (company name): of Nova Electric LLC Tony Trammell CURRENT MAILING ADDRESS: 2407 E Loop 820 N. CrrY/STATUZIP; Fort Worth, TX 76118 PH-. jV 817-616-3152 Fax PROPERTY OWNER: Craig Martin CURRENT MA10LING ADDRESS: 4345 Woodg le n Dr CITY/STATE/ZIP: Grapvine, TX 76051 PHONE NUMBER: 214-519-464 -PROJECT VALUE: $.35000.00 FIRE SPRINKLERED? YES NO x WHAT TRADES WILL BE NEEDED?(Check ones that apply) ELECTRIC X PLUMBING _ MECHANICAL DESCRIPTION OF WORK TO BE DONE; 11.340 kW DC Roof Mount Solar System with Back Up Bafteries USE OF BUILDING OR STRUCTURE: Residence PZ. BOX 95104, GRAPEVINE, TX 76099 (817) 410.3165 WORMMI)SPERMITAPPUGATIONS DDRESS 4345 Woodglen Dr Grapevine, TX 76051 LEGAL Glade Crossing 2a & 2b Blk 4 Lot 6 S Glade Crossing 2a & 2b Block 4 Lot 6 PERMIT HOLDER Tony Trammell Sol Nova Electric LLC (832) 414-1390 COLLABORATORS •Tony Trammell Sol Nova Electric LLC (832) 414-1390 OWNERS • INSPECTIONS 1 1. Building Final INFORMATION FIELDS **APPLICANT NAME (Individual)Tony Trammell **APPLICANT PHONE NUMBER 8176163152 APPLICANT E-MAIL VALUATION 35001 * CONSTRUCTION TYPE VB * OCCUPANCY GROUP R-3 DOCUMENTS - MISC 01 APPLICATION.pdf DOCUMENTS - MISC 02 Craig Martin Engineering 2-12-2025- compressed.pdf * ZONING DISTRICT R-7.5 APPROVED TO ISSUE ELECTRIC YES FEE TOTAL PAID DUE Building Permit Fee, ($150.00 Flat Fee) Simple Alteration $ 150.00 $ 150.00 $ 150.00 TOTALS $ 150.00 $ 150.00 $ 0.00 READ AND SIGN I HEREBY CERTIFY THAT THE FOREGOING IS CORRECT TO THE BEST OF MY KNOWLEDGE AND ALL WORK WILL BE PERFORMED ACCORDING TO THE DOCUMENTS APPROVED BY THE BUILDING DEPARTMENT AND IN COMPLIANCE WITH THE CITY OF GRAPEVINE ORDINANCE REGULATING CONSTRUCTION. IT IS UNDERSTOOD THAT THE ISSUANCE OF THIS PERMIT DOES NOT GRANT OR AUTHORIZE ANY VIOLATION OF ANY CODE OR ORDINANCE OF THE CITY OF GRAPEVINE. I FURTHERMORE UNDERSTAND THAT PLANS AND SPECIFICATIONS ARE NOT REVIEWED FOR HANDICAPPED ACCESSIBILITY BY THE CITY AND THAT THE DESIGN PROFESSIONAL / OWNER IS RESPONSIBLE FOR OBTAINING SUCH APPROVAL FROM THE APPROPRIATE STATE AND OR FEDERAL AGENCY(S). City of Grapevine PO Box 95104 Grapevine, Texas 76099 817) 410-3166 Building - Residential Alteration Project # 25-000662 Project Description: Install 11.340 kW DC Roof Mount Solar with Back-Up Batteries [ELECTRONIC REVIEW] Issued on: 03/11/2025 at 8:36 AM MYGOV.US 25-000662, 03/11/2025 at 8:36 AM Issued by: Connie Cook Page 1/2 Scott Leavelle From: Scott Leavelle Sent: Thursday, February 27, 2025 8 03 AM To: Cc: Arnoldo Ramirez Subject: 25-000662; 4345 Woodglen Dr- Grapevine. TX (Solar Panels 9-31= Review of the permit application referenced in the subject of this email has been completed. Permit approval is denied pending receipt • -.•r to the following • 1. Provide a signed and sealed Engineer's report stating the existing structure is adequate to support the new load. W. Scott Leavelle Assistant Building Official City of Grapevinte 200 S. Main St. Grappvine, TX 76051 p: 817.410-3161 TSBPE License # 1-2430 8 MODULES - 11340 kW DC, 9.746 kW AC SYSTEM SIZE MARTIN RESIDENCEWOODGLEN DRIVE, GRAPEVINE, TX 76051 ESID: 1044372000241803A, AERIAL MAP NTS I VICINITY MAP NTS 8 GOVERNING CODES kj C M av011"] 2020 NATIONAL ELECTRIC CODE I UILD�NG CODE 20211 INTE RNATONAL B E� s ve' 202 INTERNATIONAL. RESIDENTIAL CODE 2021 INTERNATIONAL FIRE CODE fC !V 2021 INTERNATIONAL FUEL GAS CODE 2021 INTERNATIONAL EXISTING BUILDING CODE 20,� INTERNAT ONAL ENERGY CONSERVAl I ION CODE 2021 INTERNATIONAL MECHANICAL CODE 2021 INTERNATIONAL PLUMBING CODE AS ADOPTED BY GRAPEVINE INCLUDING ANY AMENDMENTS OR ADDITIONAL LISTED REQUIREMENTS DESIGNED INACCORCANCEWI'FH'THEREQUIREMENTS ,DFGNCCIRUTILITY EQUIPMENT IS COMPATIBLE WITH LJI-270, JLl 741, LL 17 0, / JlUr, 1730, AND UL9540A AS APPLICABLE WIND SPEED, 115KIPH GROUND SN�'W LOAD 5 PSF ASCE 7-IA EXPOSURE CATEG GRY C 81ALDINGOCCIJPANCY R-3 '-'ONSTRUCTION TYPE TYPE V-B SPRINKLERS NO PV-1 COVER PAGE PV-2 SITE PLAN PV-3 PROPERTY PLAN PV-4 ATTACHMENT PLAN PV-5 MOUNTING' DETAILS EE-1 STRING PLAN EE-2 THREE LINE DIAGRAM EE-, ELECTRICAL NOTES EE-� 1 EL EVAT !CN DETAILS EE-4 LABELS EIE-5 PLACARD PV-rl DESIGN NOTES Pv-ll SITE PHOTOS SPEC SPECIFICATION SHEETS sTMT-TV rl "M . M- SYSrEM SIZE, 11 340kW DC r 9 746kWA(,' SYSTEM SIZE PVMODULE 128, HYPERION HY-DH 108Po 405W !NVERTER (13)DURACELLD700-M2 (21DURACELL D350-1,11 COMBINER (1)MIN IMUNI 125A LOAD CENTER AC DISCONNECT; 12! 60AFU$ED AC DISCONNECTA FUSED A:: DIS;-C)NNECT BATTERY: (2) SONNENCCRE, SGDRE-P20 ROOF STORIES 2 ROOFTYPE(S) ;.OMP SHINGLE NIIOUNTING(8,�) RACKING(S) UNIRAC STRONGHOLD BUTYL FOOT WITH UNIRAC NXT RAIL FLASHING UNIRAC BUTYL ROOF BEING REPLACED NO ROOF CONDITION GOOD ROOF HEIGHT 25 FEET RK)OFOONSTRUCTiON MIXED HIP -GABLE INTERCONNECTION SERVICE INTERCEPT MAIN SERVICE PANEL LOCATION 1ST FLOOR MAIN SERVICE PANEL RATING (E) 225A MAIN BREAKER RATING (E)200A 60AFUSE METERNUMBER 166064292 METER LOCATION. I IT FLOOR RECEIVED: 2/21/2025 25-000662 4345 WOODGLEN DRIVE SOLAR PANELS 1:U0 1 sz'� OIN DATE REVISION 2,11,2025 BATTERY LOCATION PHOTO DESIGN ENGINEER SLING 76 IN, MEADOWSROOK DRIVE ALPINE LIT 84004 com (20 1) E574-3483 FIRM NO 20109 SOLAR COMPANY/CLIENT SOLNOVA ELECTRIC LLC 330 RANCHEROS DR SAN MARCOS, CA MARTIN RESIDENCE 4345 WOODGLEN DRIVE "RAPEVINE, TX 76051 COORDINATES 22Vl0%,-1j7084865 ESID 10443720+,n2418034 (2141 515-4C,64 COVER PAGE �"t Aipw Signed 2/12/2026 DO SYSTEM SIZE 11 34-"kW AC SYSTEM SIZE 9 -,4'3kW BATTERY SYSTEM SIZE 40 PV-1 AHJ 13RAPEVINE UTILITY ONCOR DRAWN BY CM$ INITIAL DESIGN DATE 02,10,2025 (5 SYSTEM INFORMATION MODULE 128) HYPERION HY-DH108P3 COUNTITYPE 40FW INVERTER 03 l DURACELL D700412 COUNT,lrYPE (2)DURAUELL MODI - JUE 4982LBS WEIGHT MODULE 36" x 44 65" DIMENSIONS UNIT WEIGHT Or ARRAY 2 'S PSF LEGEND ROOF VENT ITYP ) El PLUMBING VENT (TYP) 0 A;C UNIT AC SATELLITE DISH ELECTRICAL MAST CHIMNEY PIRECODE PATHWAY BPTTERY MODEL S,3NNENCORE+ SCORE-P2-,, CAPACITY TY 2r,000WIn MAX CURRENT 32A FRE•CUENCY G('Hz VOLTAGE 240V ROOF DESCRIPTION ROOF 9 ROOF TYPE TUT PITCH AZIMUTH ROOF FRAMING MODULE COUNT I CCNIPSHINGLE 154" 3512 2>O(T-24C.C.RAFTERS 21 2 CONIP SHINGLE 3 7 13' 95,12 271' 2X6(,1�24",:) C RAFTERS TOTAL ROOF AREA SO FT 1 2161 TOTAL ARRAY SQ FT DESIGN ENGINEER ARRAY SO FT 443 LING 148 IROOF COVER 1 27 31 —(N)AG COMBINER ----(Nj PV AC- DISC'.ONNECT ----i N) AC: HUB �N�BATTERY— ---- 4N) VISIBLE LOIKABLE LABELED UTIL.ITY AC DISCONNE-'T N BATTER OR METER VE)GNC BACK UF LOADS PANEL IE) MAIN SERVICE PANEL. �ONCRETE FILLED PIPE BOLLARD-- 36" EXPOSED 3" CIA SCH 80 MIN 36' MIN EMBEDMENT EMBEDDED IN 6" CONCRETE PIER FIRE OFFSET z 0 X < �,-4N- --r— PV MODULE EQUIPPED W, (1) MICRO INVERTER PER (11 MODULES I I I FIRE OFFSET MODULE (28)HYPERl0NHY-DH108P8405VV INVERTER 04iDURACELLD7004,1224CIV BATTERY (2) SONNENCORE, SCORE-P20 SITE PLAN NOTES 1 ALL CBS TRUCT IONS MUST BE VERIFIED BEFORE WORK COMMENCES 2 CONDUIT TO BE RUN IN ATTIC IF POSSIBLE VISIBLE LOCKABLE LABELED UTILITY AC DISCONNECT WILL BE INSTALLED WITHIN lu'OFONCORMETER AC DISC CNNEDT SHALL BE READILY ACCESSIBLE 24','- SMOKE,'CARBON DETECTOR OR HEAT CETECTORTO BE INSTALLED WHERE REQUIRED BY R328L,' NEW DETECTORS!ALARMS TO BE INTERCONNECTED WITH EXISTING DETECTORS'ALARMS ON SITE MAIN SERVICE PANEL LOCATION ISTFLOOR METER 1-0-TION A , 1S' I'Ll, SC,ALE: 1116- 1'-()' 76 N. MEA0OWSR00K DRIVE ALPINE LIT 84004 wvys aIjny(dmys YIloqr cnsahmg corn (201) y74-34b3 FIRM NO 20109 SOLAR COMPANYICLIENT SOLNOVA ELECTRIC LLC 130 RANCHEROS DR SAN MARCOS, CA MARTIN RESIDENCE 4345 WOOCGUEN DRIVE GRAPEVINE, TX 76051 COCRDINATES 32 8910E69,-97 08481,5 ESID 10442II0024180S4 (214 15 1 A U',4 SITE PLAN OF le 4 SCOTT E WYSSLJNG AL PLL1 t�xl Signed 2112/2025 DC SYSTEM %E 1101, 34W , AC SYSTEM SIZE. ') 46AW BATTERY SYSTEM . SIZE 40 OOOkWh PV-2 AHU GRAPEVINE UTILITY ONCOR DRAM BY CMS INITIAL DESIGN DATE 02!1012025 FENIE-:1 t IAIN'1�13UIE t WIN HJUIE DRIVEWAY j 74'- 11 41T-B" 34'-1 Ttl L— — — — — — — -- — — — — — L FENCE DESIGN ENGINEER LING 76 N. MEADOWBROOK DRIVE ALPINE UT 84004 FIRM WD 20109 SOLAR COMPANYICLIENT SOLNOVA ELECTRIC LLC '3c RANCHERCS DR SAN MARCOS, CA MARTIN RESIDENCE 4345 WCODGLEN DRIVE GRAPEVINE, TX 7,6051 COORDINATES ' 2 084865 ESID 10443720002418034 t 214 � 51 �-4 564 PROPERTY PLAN t SCALE 1/16" = 1 -0" $61T E WYSSUN'r, v. 122669 ,it .!CE Signed 2/1212026 DC SYSTEM SIZE 11 3401,W AC SYSTEM SIZEL9 743kW BATTERY SYSTEM SIZE 40 OOOkWh PV-3 AHU GRAPEVINE UTILITY ONCOR DRAWNBY CMS INITIAL [)ESIGN DATE 02/10,2025 TTACHMENT DESCRIPTION ROOF ARRAY ROOF TYPE TILT AZIMUTH 0 TILT ROOF FRMCNG TOTAL MAX MAX POINTS SPACING CANTILEVER MIN ATTACHMENT EMBEDMENT 1 COMP SHINGLE 15 4' 15 4" 91 2X60,124"0,- RAFTERS 52 72" 113" (2) 914 SCREW 151, 4 COMP SHINGLE 3-f;,3765' 271' 2X6@24 0 C RAFTERS 16 -121, 16' (2) 914 SCREW I sl" PV MODULES: t28)HYPERtON HY-DH I OtiP8 405W ROOF 1 YPE(Sl: COMP SHIN13LE ROOF CONDITICN GOOD MOUNTING TYFi(S+ UNIRAC STRONGHOLDBUTYL FOOT WITH UNIRAC NXT RAIL FLASHING UNIRAC BUTYL ROOF HEIGHT, G5' 18" FIRE OFFSET RCOF FRAM ING MATERAL, WOOD 36" FIRE OFFSET DECKING THICKNESS 112' -ANTLEVER DI STANCE I I" TOTAL ATTACHMENTS68 2" MAX A, TACHMENT SPA,, CANTILEVER DISTANCE: lvt` ------------ 24 ATTIC MEMSERSP) EXACT LOCATION OF ROOF FOAMING MAY VARY, INSTALLER TO FOLLOW ENGINEER {VVHERE APRIL U'ABLE) AND MANUFACTURER INSTRUCTIONS.'GUIDELINES WHEN INSTALLING SCALE ?32` - V-0' DESIGN ENGINEER LING 76 N. MEADOWSROOK DRIVE ALPINE UT 84004 3wys s11liq@wys"h"gconsuffing ^ 'n tA) 11 874-3463 FIRM NO 20109 SOLAR COMPANYICLIENT SOLNOVA ELECTRIC LLC ,30 RANCHEROS DR SAN MARCOS, CA MARTIN RESIDENCE 4345 WCODGLEN DRIVE GRAPEVINE, TX 7,6051 COORDINATES ' 2 084865 ESID 10443720002418034 (214+';19-4t',64 ATTACHMENT PLAN IN' 122669 llil�p ------ A SX4 Signed 2112/2025 DO SYSTEM SIZE 11 3401,W AC SYSTEM SIZE, 9 746kW BATTERY SYSTEM SIZE 40 OOOkWh PV-4 AHJ GRAPEVINE UTILITY ONCOR DRAWNBY CMS INITIAL [)ESIGN DATE 02/10,2025 ROOFSECTIONSI RT R2 I WIND SPEED 115MPH I GROUND SNOWLOAD5 PSF I ROOF TYPE COMP SHINGLE I ROOF LAYERS (IF APPLICABLE) 1 GENERAL ROOF MOUNT DETAIL NTS MOUNTING HARDWARE PV MODULE m ROOF SHEATHING STRONGHOLD BUTYL FOOT SEE ROOF MOUNT CROSS SECTION DETAIL THIS SHEET FOR CONNECTION TO ROOF FRAMING (2) -14 S� MIN EMBEDMENT DEPTH SEE TABLE ON PV4 ROOF FRAMING SEE TABLE ON PV4 NOTE ALL ROOF PENETRATIONS MIJSTBE SEALED OR FLASHED USING APPROVED MEANS ROOF MOUNT CROSS SECTION DETAIL NTS 3" MIN - 63" MAX SPACE FROM ROOF SURFACE FINIi-HEDROOF HIM (2 f 914 SCREW SS ROOF MOUNT PLAN VIEW DETAIL NTS STRONGHOLD BUTYL DESIGN ENGINEER LING 76 N. IMEA00INBROOK DRIVE ALPINE LIT 84004 wvys aljny(dmys sLnyrcnsahmg corn (201) S74'34b3 FIRM NO 20109 SOLAR COMPANYICLIENT SOLNOVA ELECTRIC LLC 230 RANCHEROS DR SAN MARCOS, CA MARTIN RESIDENCE 4345 WOOCGLEN DRIVE GRAPEVINE, TX 76051 COCRIDINATES 32 8910E69,-97 08481,5 ESID 1044�7200024180S4 t 214) 5 1 9.A ',64 MOUNTING DETAILS fs OF SCOTT E WY . MING I Z2669 AL rg Ca P3 L-C Signed 2112/2025 DO SYSTEM SIZE 11 340kW AC SYSTEM SIZE; 9 746kW BATTERY SYSTEM SIZE 40000kWh PV-5 AHJ GRAPEVINE UTILITY ONCOR DRAM BY CMS INITIAL DESIGN DATE 02!1012025 MODULE (28) HYPERION HY-DHI08P8405W INVERTER. H 3) DURACELL 0700-M2 (2) DURACELL D350-M1 COMBINER (1) M INIIVIUM 125A LOAD CENTER STRING 1 (14) MODULES (7) D700,M2 INVERTERS STRING 2 (14) MODULES (6) D700-M2 INVERTERS (2) D190,101 INVERTERS STRING I STRING 2 MODULE E01.11PPED WITH (1) D35(1411 INVERTER ------ (m SCALE 312'= l'-O' DESIGN ENGINEER MNG 76 N. MCADOWISROOK DRIVE ALPINE UT 84004 in FIRM NO 20109 SOLAR COMPANYICLIENT SOLNOVA ELECTRIC LUC 33f) RANCHEROS DR SAN MARCOS, CA MARTIN RESIDENCE 4345 WCODGLEN DRIVE GRAPEVINE, TX 7,6051 COORDINATES ' 2 084865 ESID 10443720002418034 4214) 519-4C,64 STRING PLAN DC SYSTEM SIZE 11 M0kW AC SYSTEM SIZE'. 9 ';46kW BATTERY SYSTEM SIZE 40 000kWh GE-7 AHJ GRAPEVINE UTILITY CNCOR DRAWN BY' CM$ INITIAL DESIGN DATE 02/110.2025 CONDUCTOR S _HEDUL E MODULE TYPE: (28) HYPERION HY-DHI 06P8 40 WV WIRE AMPERAGE INVERTER TYPE: (il) DURACELL D700-M2 240V TAG il WIRES IN I MINIMUM TYPE, MINIMUM GROUND GROUND CONDUIT AMPS {BEFORE 1 251`o TOTAL RAT ING TABLE (2) DURACELL D35,�,Ml 240V CONDUIT WIRE SIZE MATERIAL WIRE SIZE TYPE,MATERIAL SAFETY FACTOR) AMPS 10 16(B)i 16) BATTERY !2)SONNENC_DRE,SCORE-P20 A #10 AWG THWNI CU 96 NAG BARE CU 314 EMT 203 25 ll? 15 3 9l7AVVG THVVN-2, CU #10 AWG THWN-2, CU 34 EMT 203 2538 '15 C 4 96 AWG THVVN-2, CIJ #10 AWG THWN-2, CU _'!4 EMT 40 j 5) 75 65 D 4 -8 AWG THWN-2, OU # 10 AWG THVVN-2, CU 314 EMT 3L 40 50 E 4 .31/0 AWG THVN-2, CLI -6 AWG THVVN-2, CU 2 EMT N A 200 200 F 3 03:0 AWG THWN-2, CU NA NA 2 EMT NA 200 20CI (N)240V,q,IINIMUM 125AI OAD CENTER NEMA 3R RATED N1 IN MUM 1 CK IAO. LOCAT ION: NORTH WALL MODULE TYPE t 14) FY PERION HY-OH1 08P8 405VV INVERTER TYPE (7) DURACELL D'00,M2 iUP TO,2) MrOUILE, PER MICRO INVERTER) Fw_= VISIBLE -OPEN LOCKABLE LABELED AD DISCONNECT TO BE LOCATED IN A READILY ACCESSIBLE LOCATION WITHIN 10'13F THE ONCOR METER 'Ni200AAC CONNECTIONS HUB (AC HUB), 60 Hz, TYPE 3R LOCATION IN HOUSE SONNEN CONSUMPTION CTS SONNEN PRODUCTION CT (N) UTILITY PV AC DISCONNECT 240Vr60A NEKIIA 3R 10,0KAIC FUSIBLE (UJAFUSESVISIBIL&OPEN 2P-30A LOCKABLE, LABELED 2-POLE SIEMENS GF222NRA LOCAI ON NORTH WALL 2P-,10A MOLULETVIPE (14)HYPERIONHY,DHI08PP415V'1,14(,N/ ---------- INVERTERTYPE j6}DURACELLD71104,42 (UP 10 (2) MODULE PER MICRO INVERTER! INVERTER TYPE 12) DURACELL DJ'0R I PER r"J"_ RI) INVERTER, (UP TO �1) N ODLI-E GRID IMICRO GRID GRID GPin R_ SvNNENCORE+ SONNENCORE, SCORE-P201 BATTERY SCORE-P20 BATTERY RRINIARY) ISECONDARY) LOCATION LOCATION IN HOUSE IN HOUSE DURACELL DTU PIN PO-PRO,C ETHERNET SWITCH HOMEOWNER ROUTER (N)UTILITY PV AC DISCCNNECT 24QW200A NEVA R 100KAIC FUSIBLE 200AFUSES VISIBLE -OPEN LOCKABLE, LABELED 2-PGUE RAPID SHUTDOWN DEVI,.-,E MINIMUM 00PID 30 40 200 2130 METER NUMBER 1�36OR42Q (E) ONCOR METER 120:14OV SINGLE PHASE 3-WIRE 0 r FACIT[LITYGROUND ? E) GROUND ROD (E) WATER BOND IE)20CAMAIN,l EREAKER (E) 22EA RATED MAIN SERVIk"R PANEL (E)L OAC E tE)200A MAIN BREAKER 10KAIC LOCATION IN HOUSE IN)?P-1 (UA, IN) NON ESSENTIAL LOADS CONTACTOR 10KAIC MODEL * AF96-30-00-12, �,N p U! - nc' DESIGN ENGINEER % LING kcf� 76 N. MCADOWBROOK DRIVE ALPINE UT 84004 in FIRM NO 20109 SOLAR COMPANYICLIENT SOLNOVA ELECTRIC LLC 33f) RANCHEROS DR SAN MARCOS, CA MARTIN RESIDENCE 4345 WCOOGUEN DRIVE GRAPEVINE, TX 7,6051 COORDINATES ' 2 084865 ESID 1044372,1002418034 (214)512-4L64 THREE LINE DIAGRAM tEjLOADS D,' SYSTEM 40kW %E IN) NON ESSENTIAL LOADS AC SYSTEM SIZE. 9 746kW (E)LOADS PANEL BATTERY SYSTEM SIZE 40 000kWh LOCATION IN HOUSE jE L CALS EE-2 AHU GRAPEVINE UTILITY CNCCR (E)LOADS DRAVVNBY CMS INITIAL DESIGN DATE 02/110:2025 �! iW MODEL HYPER ON 1( HY-DHICIW8 405W PMAX 405W voc 2UV VI'llp 3121V IMP 12 9SA Isc 1, MAX SERIES FUSE -A RATING , upf:�� MODEL DURACELL D7004,12 MAX INPUT DO VOLTAGE 60V MAX DO CURRENT 15A MAX OUTPUT POWER MAXIMUM CCNT 2 9A OUTPUT CURRENT CEC EFFICIENCY J 165 NOMINAL AC 240V VOLTAGE MAX UNIT$ PER 20A CIRCUIT 41111:cll Oil rq_ll 111101 1p, INVERTER MODEL DURACELL D350-M1 MAX INPUT DC VCL TAGS POV MAX DO , CURRENT 15A MAX OUTPUT POWER I 49 W MAXIMUM CONT , �UTPUTCURRENT 1AFA CEC EFFICIENCY 0535 NOMINAL AD 24 OV VOLTAGE MAX UNITS PER 20A CIRCUIT TAG A TAG 8 FROM MODU4ES TO ,;UNCTION BOX FROM JUNCTION BOX TO AC COMBINER LARGEST STRING 14 MODULES LARGEST STRING, 14 MCOULES NUMBER OF INVERTERS NUMBER OF INVERTERS AMPS PER INVERTER: 2 9 AMPS PER INVERTER' 2 7 * 2 9A = 20 ON * 1 2F - 25,i8ATOTAL AMPS 7 12 9A = 20 'A 1 1 25 = 25 2RATOTAL AMPS ,CONDUCTOR SIZE, 410AWG CONDUCTOR SIZE g 10 AWG CONDUCTOR MAX 3EA, GOOD CONDUCTOR MAX 75A, GOOD OCPD 30A, GOOD OCPD 30A,GGOD TAG 0 FROM BACK UP LOADS TO BATTERY FROM BATTERY TO INTERCONNECTION SIZED BASED ON BATTERY SYSTEM BATTERY OUTPUT 32A 32 A 1 1 25 = 4nA CONDUCTOR SIZE #8 AWG CONDUCTOR MAX 50A, GOOD OCPD 40A, GOOD TAG E & F RATED FOR 40A SERVICE CONDUCTOR SIZE, #;Q AVIC CONDUCTOR MAX 200A GOOD 0CPD 200A, GOOD TEMPERATURE CORRECTED VOC MCOULE SOS -C'LBEST ADIUSTED IINVERTER voc. GOEFFII.-,IENT TEMPERATURE VOC MAX 7 23 -Cl 304 1 - ?" 9 41 l'i 60, GOOD DESIGN ENGINEER BATTERY SONNENCORE, MODEL LING % kc�f� SCORE-P20 CAPACITY 2000Wn 76 N. MEADOWBROOK DRIVE MAX CURRENT 32A ALPINE UT 84004 in t2011874-34bl FIRM NO 20109 FREQUENCY Co Hz SOLAR COMPANYICLIENT VOLTAGE 240V TAG C FROM COMBINER TG BACK UP LOADS TOTAL K40CIJLES 28 TOTAL INVERTERS 14 AMPS PER INVERTER: 2 9A, 1 45A 13 Y 2 ',A 1 2 Y 1.45A = 40 CA'l 25 = 5o 75A TOTAL AMPS CONDUCTOR SIZE 10 AWG CONDUCTOR MAX 136& GOOD OCPD 30A. GOOD SOLNOVA ELECTRIC LLC 337) RANCHEROS DR SAN MARCOS, CA MARTIN RESIDENCE 4345 WCOOGUEN DRIVE GRAPEVINE, TX 7,6051 COORDINATES ' 2 084865 ESID 10443720002418034 (214+ 51�-4,64 ELECTRICAL NOTES D,' SYSTEM SIZE 11 34rjkW AC SYSTEM SIZE, 9 746kW BATTERY SYSTEM SIZE 40 000kWh EE-3 AHJ 13RAPEVINE UTILITY CNCOR DRAWN BY' CMS INITIAL DESIGN DATE 02/110.2025 AT POINTOF INTER:- ONNECTION, MARKED AT DISCONNECTING MEANS [NEC 690 561 POINT OP,� INTERCONN -TION [NEC, 705 12(C 5P) EA-H PV SYSTEM DISCONNECTING MEANS SHALL PLAINLY INDICATE WHETHER IN THE OPEN tOFFIOR CLOSED ,_ R. (ON 1 POSITION AND BE PERMANENTLY MARKED [NEC C90 1 CtB)l 4� AT EACH DO CIS,--ONNECTING MEANS [NEC 630,13(B)l 5) AT E&,H AC DISCONNECTING MEANS [NEC 690 13(B)l St— Llll� AT EXPOSED RACEWAYS, CABLE TRAYS, AND. OTHER -ED WIRING METHODS; SPAC AT MAXIMUM 10 FT SECTION OR W-fERE SEPARATED BY ENCLOSURES, WALLS, PARTITIONS, CEILINGS, OR FLOORS [NEC 6903I(DN2)) 7) AT BUILDING ORSTRUCTURE -3 MAIN DISCONNECTING MEANS A ELECTRICAL--- CKHAZARD - ­ - - -- [NEC O)ij 12(E), NEC010 13(B)) AT AC, COMBINER PANEL [NEC 690 13(B)j 'Cli SOLAR PV SYSTEM EQUIPPED WITH RAPID SHUTDOWN A PERMANENT WARNING LABEL SHALL BE APPLIED TO THE DISTRIBUTION EQUIPMENT' ADJACENT TO THE BACK FED BREAKER FROM THE INVERTER (NEC 705 12(B;(2!ItDREAKER INTERCONNECTION ONLY! FOR PV SYSTEMS THAT SHUT C+OVVNTHE ARRAY AND CONCUCTORS LEAViN,3THE ARRAY THE TITLE "SOLAR PV SYSTEM IS EQUIPPED WITH RAPID SHUTDOWN" SHALL UTILIZED CAPITAL IZED CHARACTERS WITH A MINIMUM HEIGHT OF 318 IN IN BLACK ON YELLOW BACKGROUND, AND t HE REMAINING , CHARACTERS SHALL, BE CAPITALIZED WITH A M INIMUM HEIGHT Or 3'1�, IN IN BLACK ON WHITE BACKGROUND [NEC 69012(l),] A RAPID SHUTDOWN SWITCH SHALL HAVE A LABELED LOCATED ON OR NO MORE THAN 8 FT FROM THE SWITCH THAT INCLUDES TH6 WORDING THE LABEL SHALL BE REFLECTIVE, WITH ALL LETTERS CAPITALIZED AND HAVING A M;NINI UP HEIGHT OF 3!8 IN, IN WHITE ON RED BA-KCROUND [NEC �390 12IL`f21) DESIGN ENGINEER TC, BE LOCATED AT MAIN SERVICE PANEL LING (5, CNNEN BATTERY % kc� TO BE LOCATED AT BATTERY 76 N. MEADOWBROOK DRIVE SHUTDOWN SWITCH ALPINE UT 84004 )2 KC NEC, 06AF(C) in FIRM NO 20109 AT EXTERNAL LOCATION NEAR 1 METER AND UTILITY SERVICE SOLAR COMPANYICLIENT DISCONNECT PLACE LABEL EXTERNAL Al MAIN SERVICE DIRCCNINECI SOLNOVA ELECTRIC LLC 331) RANCHEROS DR ij- 4 PLACE ES8 LABELS AT SAN MARCOS, CA BATTERY ANCrOR CONTROLLER MARTIN RESIDENCE 4345 WOODGLEN DRIVE GRAPEVINE, TX 7,6051 COORDINATES ' 2 084865 ESID 10443720002418034 t2141519-4664 LABELS LABELING NOTES: I LABELS CALLED OUT ACCORDING TO ALL. COMMON CONFIGURATIONS ELD-TRICIAN TO DETERMINE EXACT REQU REM ENTS IN THE P [ELD PER CURRENT NEC AND LOCAL CODES AND MAK E APPRCPRIAT E ADJUST MENTS 2 LABELING REQUIREMENTS BASED DN THE NATIONAL ELECTRIC CODE,CISHASTANDARD 19610 145,ANSIZ535 MATERIAL BASED ON THE REQUIREMENTS OF THE AUTHORITY HAVING JURISDICTION 4 LABELS TO BE OP SUFFICIENT CURABILITY TO WITHSTAND THE DCSYSTENI SIZE 113,4rjkW ENVIRONMENT INVOLVED [NEC 110 211 THEY SHALL BE A' , ' SYSTEM SIZE, 9 746kW PERMANENTLY ATTACHED, WEATHER)SUNLIGHT RESISTANT, BATTERY SYSTEM SIZE 40 000kWh AND SHALL NOT BE HAND WRITTEN PER NEC 110 2 1 IS) EE-4 5 APPLICABLE LABELS TO BE A MINIMUM LETTER HEIGHT OF 3/8", WHITE ON RED 6AlKlR,,UNDE REFLECTIVE. AND PERMANENTLY AHj GRAPEVINE AFFIXED [PC 60511 1 11 UTILITY CNCOR DRAWN BY' CM$ INITIAL DESIGN DATE 02/110:2025 I E,:UIPMENT SHALL. BE MINIMUM OF ','X "ACCESSIBLE WORKSPACE, FLAT. AND la,EAR OF CEBR IS AND OBSTACLES (TREES, BUSHES, PLANTS, ETC) 2 BATTERIES TO BE SEPARATED BY Ana INIMUM,'_lF w'BETWEEN EA!'H UNIT PER UL 9540A REPORT AND4OR MANUFACTURER SPEC IF ICAT tONS, VVHQHEVER IS GREATER DISTANCE 3 EXTER1,3R ESS UNlTjSi WILL NOT BE INSTALLED WITHIN ? FEET (IN ANY DIRECTION) OF ALL DOOR$, WINDOWS, OPERABLE OPENINGS INTO BUILDING AND HVAC INLETS 4 DIAGRAM NOT TO SCALE Rd FtFR T21 T. IV "1', C. -.811110 NORTH INTERIOR ELEVATION DETAIL DESIGN ENGINEER MNG 76 N. MEADOWISROOK DRIVE ALPINE LIT 84004 in FIRM NO 20109 SOLAR COMPANYICLIENT SOLNOVA ELECTRIC LLC 33f) RANCHEROS DR SAN MARCOS, CA MARTIN RESIDENCE 4345 WCODGLEN DRIVE GRAPEVINE, TX 7,6051 COORDINATES ' 2 084865 ESID 1 t214) 51914L64 ELEVATION DETAILS DC SYSTEM SIZE 113401,W AC SYSTEM SIZE, 9 746kV/ BATTERY SYSTEM SIZE 40 000kWh EE-3.1 AHJ GRAPEVINE UTILITY CNDOR DRAWN BY' CMS INITIAL DESIGN DATE 02/110:2025 DESIGN ENGINEER % SSLING kcf, � 76 N. MEADOWSROOK DRIVE ALPINE LIT 84004 t2011 FJ'74-34b3 FIRM NO 20109 SOLAR COMPANYICLIENT CAUTION lv� MULTIPLE SOURCES OF POWER LNOVA POWER IS SUPPLIED TO THIS BUILDING SO33f) RMCHEROS ELECTRIC DRLLC FROM THE FOLLOWING SOURCES WITH SAN MARCOS, CA DISCONNECTS AS SHOWN. MARTIN RESIDENCE AC COMBINER 4345WOODGLENDRIVE N GRAPEVINE, TX7e05i V AC DISCONNECT COORDINATES ' 2 084865 C HUB ESID 104437200024*0��4 VISIBLE AC DISCONNECT (2141519-46634 ETER ACK UP LOADS PANEL PLACARD MAIN SERVICE PANEL (2) BATTERIE H PV MODUL I u, 4345 WOODGLEN DRIVE GRAPEVINE,TX 76051 LOCATION M$P EC N 70510 br, locr -opLn Dv SYSTEM SIZE 11 34rjkVV o to c A�'SYSTENI S(ZE: 9 74%W ➢ BATTERY SYSTEM SIZE 40 0001,Wh e u ir o" f;- EE-5 AHJ GRAPEVINE UTILITY CNCOR DRAMBY CM$ tNtTAL OE3 1GN DATE 02, 10,20 t 5 GENERAL NOTES CONTRACTOR SHALL FIELD VERIFY ALL DIMENSIONS AND REVIEW ALL MANUFACTURER INSTALLATION DOCUMENTS PRIOR TO INITIATING CONSTRUCTION ALL COMPONENTS SHALL BE NEWAND LISTED BY A RECOGNIZED ELECTRICAL TESTING LABORATORY AND LISTED FOR THEIR SPECIFIC APPLICATION OUTDOOR EQUIPMENT SHALL BE NEMA ?R RATED OR BETTER ACCESS TO ELECTRICAL COMPONENTS OVER 150 VOLTS TO GROUND SHALL BE RESTRICTED TO QUALIFIED PERSONNEL 'ONTRACTOR SHALL OBTAIN ELECTRICAL PERMITS PRIOR To INSTALLATION AND SHALL COORDINATE AL,L INSPECTIONS. TESTING CCMMISSIONiNG AND ACCEPTANCE WITH THE HOMEOWNER, UTILITY CO AND CITY INSPECTORS AS NEEDED EACICH MODULE TO BE GROUNDED USING THE SUPPLIED CONNECTION POINT PER THE MANLFA_',TI_RERS REQUIREMENTS ALL PV MODULES EQUIPMENT,AND METALLIC COMPONENTS ARE TO BE BONDED IF THE EXISTING GROUNDING ELECTRODE SYSTEM CANNOT BE VERIFIED OR IS ONLY METALLIC WATER PIPING, IT IS THE CONTRACTORS RESPONSIBILITY TO INSTALL A SUPPLEMENTAL GROUNDING ELECTRODE DO CONDUCTORS SHALL BE RUN IN EMT AND,OR MC IYIETAL CLAD CABLE} AND SHALL BE LABELED EXPOSED NON-CLIRRENT CARRYING METAL PARTS OF ELECTRICAL EQUIPMENT SHALL BE GROUNDED IN ACCOrDAN--EWTH APPLICABLE NEC CONFIRM LINE SIDE VOLTAGE AT THE ELECTRIC: UTILITY SERVICE PRIOR TO CONNEC-i INS INVERTER VERIFY SERVICE VOLTAGE IS WITHIN INVERTER VOLTAGE OPERATIONAL RANGE ELECTRICAL CONTRACTOR TO PRI'IVIDE CONDUIT EXPANSION JOINTS AND ANCHOR CONDUIT RUNS AS REQUIRED PER CODE ALL WIRING MUST BE PROPERLY SUPPORTED BY DEVICES OR MECHANICAL MEANS DESIGNED AND LISTED FOR SUCH USE, AND FOR ROOF -MOUNTED :YSTEMS, WIRING MUST BE PERMANENTLY AND COMPLETELY HELD OFF OF THE ROOF SURFACE ALL ROOF PENETRATIONS MUST BE SEALED OR FLASHED EOUIPMENT MAY BE SUBSTITUTED FOR SIMILAR EQUIPMENT BASED ON AVAILABil. ITY,SUBSTITUTED EQUIPMENT SHALL COMPLY WITH DESIGN CRITERIA REMOVAL OF AN INTERACTIVE INVERTER OR OTHER EQUIPMENT SHALL NOT DISCONNECT THE BONDING CONNECTION BETWEEN THE GROUNDING ELECTRODE CONDUCTOR AND THE PHOTOVOLTAIC SOURCE AND,OR OUTPUT CIRCUIT GROUNDED CONDUCTORS WHENEVER A DISCREPANCY IN THE QUALITY OF EQUIPMENT ARISES ON THE, DRAWING OR SPECIFICATIONS, THE CONTRACTOR SHALL BE RESPONSIBLE FOR PROVIDINGAND INSTALLING ALL MATERIAL AND SERVICES REQUIRED BY THE STRICTEST CCNIDITIONS NOTED ON THE DRAWINGS C'R IN THE SPECIFICATIONS TO ENSURE COMPLETE COMPLIANCE AND LONGEVITY OF THE OPERABLE SYSTEM REQUIRED BY THE ENGINEERS AC DISCONNECT SHALL BE LOCATED WITHIN lI)'rF ONCOR METER AC DISCONNECT SHALL BE LOCATED ON SAME WALL OF HOUSE WHERE POSSIBLE IF AC DISCONNECT CANNOT BE WITHIN J.ljE OF METER, THEN PHOTOS SHALL BE PROV!DED OF THE OBSTRUCTION FOR REVIEW IF APPLICABLE, ENERGY STORAGE SYSTEM (ESS) CAN BE USED DURING ON -GRID OPERATION TO SHIFT GENERATION FOR TIME •-f USE JOIN) AND WILL NOT OPERATE OFF GRID GENERAL ELECTRICAL NOTES CONDUIT AAI`G) 6 AMPS EQUAL TO LARGEST STRING ON TAG CONDUIT A SHALL BE RUN THROUGH ATTIC IF P,-•SSIBLE ALL WIRING MUST BE PRCPERLY SUPPORTED BY CEVICES OR MECHANICAL MEANS DESIGNED AND'CR LISTED FOR MUCH USE, AND FOR ROOF -MOUNTED SYSTEMS, WIRING MUST BE PERMANENTLY AND COMPLETELY HELD OFF Or THE ROOF SURFACE. EOUIPMENT MAY BE SUBSTITUTED FOR SIMILAR EOUIPMENT BASED ON AVAILABILITY, SUBSTITUTED ED'UPMENT SHALL COMPLY WITH DESIGN CRITERIA WIRE SIZES ARE BASED ON MINIMUMS AND ARE NOT MEANT TO LIMIT UPSIZING AS REQUIRED BY FIELD CONDITIONS AVALABIL IT Y. WIRING SHALL COMPLY WITH MAXIMUM CONTINUOUS CURRENT OUTPUT AT 25"C AND MAXIMUM VOLTAGE AT 600V, WIRE SHALL HE WET RATED AT O)%' EXPOSED PHOlr-_VOLTAV_'SY3TEP0 CONDUCTORS CN THE ROOF WILL BE TYPE 2 OR PV-TYPE WIRE PHOTOVOLTAIC SYSTEM CONDUCTORS SHALL BE IDENTFIEDAND GROUPED, THE MEANS OF IDENTIFICATION SHALL BE PERMITTED BY SEPERATE COLOR -CODING, MARKING TAPE, TAGGING OR OTHER APPROVED MEANS ALL CONDUCTCRS AND TERMINATIONS SHALL BE RATED FOR INSTALL LOCATION ALL EXTERIOR CONDUIT, FITTINGS, AND BOXES SHALL BE RAIN -TIGHT AND APPROVED FOR USE IN WET LOCATIONS ALL METALLIC RACEWAYS AND EQUIPMENT SHALL BE BONDED AND ELECTRICALLY CONTINUOUS WHERE SIZES OF JUNCTI,'.)N BOXES, RACEWAYS, AND CONDUITS ARE NOT SPECIFIED, CONTRACTOR SHALL SIZE THEM ACCORDING TO APPLICABLE CODES REMOVAL OF A UTILITY -INTERACTIVE INVERTER OR OTHER EQUIPMENT SHALL NOT DISCONNECT THE BUILDING DDINNECTION BETWEEN THE '.;ROUNDING ELECTRODE CONDUCTOR AND THE PV SOURCE AND OR OUTPUT CIRCUIT GROUNDED CONDUCTOR FOR GR--UNDED SYSTEMS, THE PHOTOVOLTAIC SOURCE AND CUTPUT CIRCUITS SHALL BE PROVIDED WITH AGROUND -FAULT PROTECTION DEVICE OR SYSTEM THAT DETECTS A GROUND FAULT, INDICATES THAT FAULT HAS OCCURRED, AND AUTOMATICALLY DISCONNECTS ALL CONDUCTORS OR CAUSES THE INVERTER TO AUTOMATICALLY CEASE SUPPLYING POVVER TO OUTPUT CIRCUITS FOR UNGROUNDED SYSTEMS, THE INVERTER IS EQUIPPED WITH GROUND FAULT PROTECTION AND A GFI FUSE PORT FOR GROUND FAULT INDICATION PV MODULE FRAMES SHALL BE BONDED TO RACKING RAIL OR BARE COPPER GEC,GEC PERTHE MODULE MANUFACTURER'S LISTED INSTRUCTION SHEET PV MODULE RACKING RAIL SHALL BE BONDED TO BARE COPPERGEC VIA WEED LUG, !L SCO GSIU,4DBT LAY IN LUG, OR EQUIVALENT LISTED ULIG THE PHOTOVCLTAIC INVERTER WILL BE LISTED AS UL 1-,41 COMPLAINT RACKING AND BONDING SYSTEM TO BE UL271O RATED ANY REQUIRED GROUNDING ELECTRODE CONDUC:TOR WILL BE CONTINUOUS EXCEPT FOR SPLICES OR JOINT', AS BUSSARS WITHIN LISTED EQUIPMENT WHEN SACKFEED BREAKER IS THE METHOD -OFUTILITY INTERCONNECTION, THE BREAKERS SHALL NOT READ"LINE AND LOAD I WHEN APPLYING THE 120`. RULE, THE SOLAR BREAKER TO BE POSITIONED AT THE OPPOSITE ENE) OF THE SUSBAR FROM THE MAIN BREAKER THE WORKING CLEARANCE AROUND THE EXISTING ELECTRICAL EQUIPMENT AS WELL AS THE NEW ELECTRICAL EQUIPMENT WILL BE MAINTAINED LISTED CONDUIT AND CONDUCTOR SIZES ARE BASED ON MINIMUM 'LODE REOUIREMENTS AND ARE NOT MEANT TO LIMIT jPSIZ[NG AS REOIJ,RECI BY FIELD COND[TIONSiAVAILABILITY DURACELL D-100-N,12 INVERTERS HAVE INTEGRATED GROUND AND DOUBLE INSULATION NO GEIC OR EGC IS REQUIRED. THE DC CIRCUIT IS ISOLATED AND INSULATED FROM GRCUNC, AND MEETS THE REQUIREMENTS OF NEC CALCULATIONS ARE BASED ONA)ASHRAE #2 AVERAGE HIGH 32'C B!NEC TABLE 310 15(B)2(a) 75'DERATE FACTOR—) 9r, C} NEC TABLE NEC 310 19(B)i 101 75—C SUPPLEMENTAL GROUNDING ELECTRODE TO BE INSTALLED NO CLOSER THAN 6FRONT EXISTING WHEN REQUIRED NEC 250 53(A)t2) DOES NOT REQUIRE IT IF CONTRACTOR CAN PROVE THAT ASINGLE ROD HAS A RESISTANCE TO EARTH OF 25 OHMS OR LESS WHEN CABLE, INCLUDING PV CABLE(S), IS RUN BETWEEN ARRAYS OR TC, JUNCTION BOXES IT SHALL BE ENCLOSED IN CONDUIT' [NEC 300 4, 690 31(A) AND C)] THE CABLE CONNECTORS USED ON THE OUTPUT SIDE or THE OPTIMIZER OR MICRO INVERTER TOGETHER WITH THE ARRAY CABLE USED BETWEEN THEM ARE OF THE SAME MANUFACTURER OR ARE L ISTED FOR COMPATIBILITY [NEC 690 ,3IC1] SOME WIRE CONNECTORS SUPPLY INSTRUCTIONS FOR THE PRELININARY PREPARATION OF CONDUCTORS, SUCH AS USE OF CONDUCTOR TERN11NAT ON COMPOUND (ANTIOXIDANT COMPOUND I. SOME CONNECTORS ARE SHIPPED PRE -FILLED WITH CONDUCTOR TERMINATION COMPOUND (ANTIOXIDANT COMPOUNDi FOR NON-PREFtLLED CONNECTORS, CONDUCTOR TERMINATION COMPOUND MAY BE USED IF RECOMMENDED BY THE CONNECTOR MANUFACTURER AS PRELIMINARY PREPARATION OF THE CONDUCTOR, DESIGN ENGINEER MNG 76 N. MCADOWBROOK DRIVE ALPINE UT 84004 in FIRM NO 20109 SOLAR COMPANYICLIENT SOLNOVA ELECTRIC LLC 30) RANCHEROS DR SAN MARCOS, CA MARTIN RESIDENCE 4345 WCIODGLEN DRIVE GRAPEVINE, TX 7,6051 COORDINATES ' 2 084865 ESID 10443720102418034 4214) 5111-4664 DESIGN NOTES D,' SYSTEM SIZE 11 340kW AC SYSTEM SIZE. 9 746kW BATTERY SYSTEM SIZE 40 000kWh PV-6 AHU GRAPEVINE UTILITY CNCOR DRAWN BY, CPS INITIAL DESIGN DATE 02,'10,2025 DESIGN ENGINEER $LJNG 76 N. MEADOWSROOK DRIVE ALPINE LIT 84004 Coln 1201,874-34b FIRM NO, 20109 SOLAR COMPANYICLIENT $OLNOVA ELECTRIC LLC '30 RANCHEROS DR SAN MARCOS, CA MARTIN RESIDENCE 4345 W0011GLEN ORNE GRAPEVINE, TX 76051 COGRDINATES ESID 164431720002418034 (2141 1,15-4CC,4 SITE PHOTOS DC SYSTEM SIZE 11 340kW AC SYSTENI SIZE 9 74NkVV BATTERY SYSTEM SIZE 40 000kWh PV-7 AW GRAPEVINE UTILITY CNCOR DRAWN BY � CMS INITIAL DESIGNDATE 02!1012025 H�� A t�v High C nb --dwe effizienc" to _­'c fokic'r' 1�'snme �'A HY-DHI08PB 108 HALF -CELL SIFACIAL MODULE Excellent weak light plrfoe ance 14ore Paver ouiput m w,qk RqM V_ny , reirMi olj and su'set Extended mechanical Doffs iance MoWe �rffied io "t"lla"I'll I ea4'-;r_ °'vvw , „_' 0I P", .'ui ii'l., Wd' '5'icc" Pa' 0 Quality guarantee Hi.g?l mdole, Qobtie.nSu,es 9 En na -tens a '-nily SQY ­0 HY-DI-111081"' 390­4'0l'v%h mechan:cal W� -- - -- ------ -- ---- ---- ------ - - --- ---- --- 7� 1" 3ip Y� zic Nklor 5 !'A ah to 40511; F-1k) —p—tu. _0 �`-Xorvfiohr 202.1 HYPERiON H'Y D11.10SP8 Er VI 0 DESIGN ENGINEER LING 76 N. MEADOWBROOK DRIVE ALPINE UT 84004 cwn 1201 i 87,4-3463 _N41-111114 A IPA Rtqc'i- F.—, Canml Compliant with U,S. Hh;h tifiobility� NEMA 6 CA R.!c 21 —pli-t NEC'201 7 & NEC-2020 flP67) 6000V 690.12,.pld shutdown surge protection DESIGN ENGINEER LING �z 5' 76 N. MEADOWBROOK DRIVE ALPINE UT 84004 com 1201 i 874-3463 INVERTER General Duty 60A, 240V, Type 3R ,-,F 777777777TT77777 7� 7799EFM ve-1 CK - W, DESIGN ENGINEER LING 76 K MEADOWBROOK DRIVE ALPINE UT 84004 corm (all } N"4 -3483 General Duty 60A, 240V,Type 3R 4 19 Il -W,h- 0, (-,A 30l,2 Data shoot US2:111061234 M111[ llIN `+— ty—l"Ha11UP"It" M.0 W01 US2 HG61234 21772024 P.O. 112 DESIGN ENGINEER MING 76 N. MEADOWSROOK DRIVE ALPINE UT 84004 coin t201 j 874-34K sonnen �As Engineering Design Tech Specs sonnenCore+ Weigh: Nw ,I-1 A�q (Glid-bM—,,a% D-- AppF Lk,bf. -- i" . IU sy.— —N,q Noise amiss;nn T-1 h--w dil-W, Mg.& m"I— .1—ft" Mea, j, Front A— Side view )'Ipi wrr:r rdt n,[ x Grid ZZ, -a oll, U! o DESIGN ENGINEER SSLING 76 N. MEADOWBROOK DRIVE ALPINE UT 84004 Com t201, 874,9483 �-"Y-Ivit PART # TABLE P/N DESCRIPTION SHBUI'YLM2 STRONGHOLD BUTYL ATT KIT ff 14S MILL SHBUTYLD2 STRONGHOLD BUTYL ATT KIT #14$ DARK RAIL CLAMP ASSY-/ 2X #14-14 TYPE AB SCREW, HWH, SS W/ #14 EPDM WASHER DTD BUTYL ATT ASSY -2 112' BUTYL 1 1/16" F ADJUSTMENT 2 5/8' PRODUCT LINE: NXT UNIOUNT DRAWING TYPE: PARTS H11 BROADWAY BLVD. NE SH BUTYL ALBUQUERQUE, NM 87102 USA R DESCRIPTION' I ATrACHMl PHONE: 505,M),6411 'NI WWW.UNIRAC.C%l REVISION DATE: 7/14/2023 DRAWING NOT TO SCALE L RAWALL D yMENIEIONI ARE 6 (PRODUCT PROTECTED BY S ONE OR MORE US PATENTS )�� k LEGAL NOTICE PART # TABLE P/N DESCRIPTION XTRABUTL SH EXTRA BUTYL PAD SH KIT RELEASE PAPER BOTH SIDES BUTYL PRODUCT LINE: NXT UMOUNT DRAWING SCALE j ALL DIMENSIONS ARE DRAWING TYPE: PARTS NOMINAL 9- 1411 BROADWAY BLVD NE ALBUQUERQUE, W $7102 USA DESCRIPTION: HUTYI PAD PRODUCT PROTECTED BY Z PHONE:50514),6111 E OR MORE US PATENTS ONE WWW.UNIRAC COII REVISION DATE: 1/10/2023 LFGAI-NOTICE !j _SHrFT DESIGN ENGINEER %1-1 -1 SSLI I NG An Ni � 76 N. MEADOWSROOK DRIVE ALPINE LIT 84004 corn (201,874-348'3 ATTACHMENT Lam-- 11 DESIGN ENGINEER 76 N. MEADOWBROOK DRIVE ALPINE UT 84004 ,vvys4,l)g@WYSsjmq cOfn 201 � $74-348� RAIL SYSTEM GROUNDING: Rails can be bonded using a MLPE & GROUNDING LUG (NULGMLPl), GROUND WEEBLUG #1 or ILSCO LAY IN LUG (GBL4DBT).At least one rall per row of modules in an array must be bonded to electrical ground. Each additional row of modules must be grounded with at least one rail tug per row or with a row -to -row bonding devise listed here. O ALTERNATE SYSTEM GROUNDING WITH ILSCO LAY -IN LUG - UNIRAC P/N 008009P.- Alternate Grounding Lug. Drill hole in rail 7/32' in diameter, deburr note and bolt through one watt of rail. Ensure Copper does contact Aluminum to avoid corrosion, SYSTEM GROUNDING WITH MLPE & GROUNDING LUG: Insert the T-nut in the rail by holding the plastic tone's tabs with thumb and middle finger. Rotate the clamp 90 deg in clockwise direction in the rail and release when aligned with rail Ensure that the T-nut is engaged in the rail profile. Place the grounding wire on the grounding plate on one of the sides of the bull, parallel to the grounding plate fLanges,Tighten bolt. ALTERNATE ROW GROUNDING WITH N/S BONDING CLAMP: Insert clamp between module rows and tighten bolt. ALTERNATE ROW GROUNDING WITH N/S BONDING CLIP: Fully seat bonding clip on each module flange to provide bond across N/S module gap, DESIGN ENGINEER WSSLING , CY-E, 76 N. MEADOWDROOK DRIVE ALPINE LIT 84004 tom 44 BONDING COM80 MID -END CLAMP ASSEMBLY Aluminum combo mid -end clamp cap with stainless steel bonding pins that pierce module frame anodization to bond module to module through clamp Stainless steel bott bonds aluminum ciamp to stainless steel Hex bolt Aluminum combo mid -end clamp rail nut with stainless steel bonding pins that pierce rail anodization to bond module to module through clamp BONDING BETWEEN THERMAL BREAKS Lug is connected at the end of each thermal break to the rail. Solid copper wire is connected across the gap to bond the two ends. BONDING RAIL SPLICE Bonding Hardware creates bond between Splice bar and each rail section. Aluminum splice bar spans across rait gap to create rail to rail bond. Rail on at least one side of splice wilt be grounded. Tabs on the grounding plate pierce anodization on the raitto bond raitto ground wire. Solid copper wire connected to lug is routed to provide final system ground connection. DESIGN ENGINEER WSSLING , CY-E, 76 N. MEADOWDROOK DRIVE ALPINE UT 84004 "wye>Nivd)" cwn t_kl' 171346?� BONDING CONNECTIONS & GROUNDING PATHS JAGE win UMOUNT�� --------------------------------------------------------------------------------------------------------------------------------------------- r BONDING MICROINVERTER MOUNT ALTERNATE ROW -TO -ROW BONDING PATHS Serrations on the bolt head remove the anodization of MLPE Row -to -row module bonding is accomplished with bonding clamp flange and bonds. with 2 integral bonding pins. Tabs on the stainless steel ground plate remove anodization Alternate method by connecting clips on either module to complete on the rail and bonds. sthe bonding path. CAUTION) • If Loose components or toose fasteners are found during periodic inspection, re -tighten immediately. Any components showing signs of corrosion or damage that compromise safety shall be replaced immediately. DESIGN ENGINEER WSSLING CY 76 N. MEADOWDROOK DRIVE ALPINE UT 84004 Cwll t201, H74.3463 - OESIGN ENGINEER WSSLING CY-EXIN�S1,1A t BONDING CONNECTIONS GROUNDING PANS _-1 r - UMOUNT- -.-=-_//��--= 76 N. MEADOWBROOK DRIVE ( PA ALPINE UT 84004 ,t, -- -�_ ",vye>btig'gO shngtxvrsut,ntgcw�m t201f HT4.3463 RACKING SYSTEM GROUND BONDING � CR IN ERTER _ - „-- MOUNTS ;v v BONDING RAIL SPLICE NDING BOfl f COMBO ALTERNATE � - CLAMPS ROW -TO -ROW BONDING METHOD 3' z. < if ( t 3 `i BONDING CONNECTIONS& GROUNDING PATHS PAGE :ILVATUMOUNT ---------------------------------- ---------------------------------------------------------------------------------------------------------- TEMPORARY BONDING CONNECTION BONDING MID CLAMPS MAINTAIN GROUND PATH AW MODULFREM OVED' r. ELECTRICAL CONSIDERATIONS NXT UMOUNT is intended to be used with PV modules that have a system voltage less than or equal to that atlowable by NEC, For standard system grounding a minimum 10AWG, 105*C copper grounding conductor should be used to ground a system, according to the National Electric Code It isthe installer's local {NEC}.responsibility to check codes,which mayvarySee betowfor interconnection information. TEMPORARY BONDING CONNECTION DURING ARRAY MAINTENANCE When removing modules for replacement or system maintenance, any module left in place that is secured with a bonding Midclamp will be property grounded. If a module adjacent to the end module of a row is removed or if any other maintenance condition leaves a module without a bonding mid clamp, a temporary bonding connection must be installed as shown • Attach I Isco SGI34 to wall of rail • Attach 11sco SGB4to module frame • Install, solid copper wire juniper to 11sco lugs C,A CA Module removal may disrupt the bonding path and could introduce the risk of electric shock. Follow above mentioned instructions to maintain the bonding path. INTERCONNECTION INFORMATION There is no size limit on how many NXT UMOUNT & PV modules can be mechanically interconnected for any given configuration, provided that the installation meets the requirements of applicable building and fire codes, GROUNDING NOTES The installation must be conducted by a Licensed and bonded electrician or solar contractor in accordance with the National Electric Code {NEC} and the authority having jurisdiction. Please refer to these resources in your Location for required grounding lug quantities specific to your project. The grounding / bonding components may overhang parts of the array so care must be made when walking around the array to avoid damage. Conductor fastener torque values depend on conductor size. See product data sheets for correct torque values, PERIODIC INSPECTION Conduct periodic inspections for Loose components, Loose fasteners or any corrosion, immediately replace any affected components. DESIGN ENGINEER FEW SSLING 7 76 N. MEADOWDROOK DRIVE ALPINE UT 84004 "wye bny'gOWY5 Cwn t201'1713463 L'�►�UMOUNT --------------------------------------------------------------------------------------------------------------------------------------------- The NXT UMOUNT system has been certified and Listed to the UL 2703 standard (Rack Mounting Systems and Clamping Devices for Flat -Plate Photovoltaic Modules and Panels). This standard included electrical grounding, electrical bonding, mechanical load and fire resistance testing. SYSTEM LEVEL FIRE CLASSIFICATION The system fire class rating requires installation in the manner specified in the NXT UMOUNT Installation Guide, NXT UMOUNT has been classified to the system level fire portion of UL 2703, NXT UMOUNT has achieved system level performance for steep sloped roofs and low sloped roofs. System level fire performance is inherent in the NXT UMOUNT design, and no additional mitigation measures are required. See table below for definition of steep sloped and tow sloped roofs, The system is to be mounted over fire resistant roof covering rated for the application. There is no required minimum or maximum height Limitation above the roof deck to maintain the system fire rating for NXT UMOUNT Approved Module Types & System Level Fire Ratings are Listed below: Roof Type Module Type System Level Fire Rating Rail Direction Module Orientation Steep Slope - roof pitches > 2 in/ft. Type 1, 2, 3 with metal frame, 10 with metal frame, 19,22,25,29, & 30 Class A Parallel OR Perpendicular to Ridge Landscape OR Portrait Low Slope - roof pitches < 2in/ft Type 1, 2,29, & 30 MECHANICAL LOAD TEST MODULES The modules selected for UL 2703 mechanical load testing were selected to represent the broadest range possible for modules on the market. The tests performed covers module frame thicknesses greater than or equal to 1,0 mm, single and double watt frame profiles (some complex frame profiles could require further analysis to determine applicability), and clear and dark anodized aluminum frames. PV modules may have a reduced load rating, independent of the NXT UMOUNT rating. Please consult the PV module manufacturer's installation guide for more information. Tested Module Design Load Ratings SunPower SPR-A440 -COM Down: 50 psf, Up: 50 psf, Slope: 15 psf )intro JKM- xxxM 72HL4-V Down: 39,47 psf, Up: 22,28 psf, Slope: 8 psf Q Celts Q Peak Duo XL-G11.3/BFG Down: 37.06 psf, Up: 20,97 psf, Slope: T53 psf UL2703 CERTIFICATION MARKING. Unirac NXT UMOUNT is listed to UL 2703. Certification marking is embossed on all Combo Clamps as shown. labels with additional certification information are provided with clamps and must be applied to the NXT UMOUNT Rail at the edge of the array Tested Loads Down: 75 psf, Up: 75 psf , Slope: 23 psf 21.86 so ft Down: 59.20 psf, Up: 33,42 psf, Slope: 12 psf 2476 5q ft Down: 55.6 psf, Up: 31A6 psf, Slope: 11.3 psf 29,49 sq ft DESIGN ENGINEER SSLING 76 N. MEADOWBROOK DRIVE ALPINE LOT 84004 tom DESIGN ENGINEER LING �z 5' 9 au 1 i I = 76 N. MEADOWISROOK DRIVE ALPINE LIT 84004 MOM 'mysshI U U COMPATIBLE MODULES t201 i 874-346? PAGE wya'slftigaotEstrt,ntg cons --------------------------------------------------------------------------------- ------------------------- ------------- ------ -------- Electrical Bonding and Grounding Test Modules The list below, is not exhaustive of compliant modules but shows those that have been evaluated and found To be electrically compatible with the NXT UMOUNT system, M .. fit- Md.t,M.dW / Series M­W­ Md.t, M.A.1 I S.,k, I M-I Module WOUSw, A -I- AICIN60A, AW1A,'.%1 8W Vt,K,> MHK-!6 5­­ i AI- P S­I & Sris 1 ­.1— r­­ Fr'lp Sq8­ rr rip! RNn-­ DNA 20 [W.sr7 Lo C' `3K-IMRfMB-ACMs'PP HERB-AGr Wc'.. I)NA "LIN'1P), "'N-'." CC 'U 0 AptrM ON4 144 MrsrjIi H­, TD AN3 TD ANO D144 L20 fMI'jBF,26 1SW MR 46j,55A r' Is A,113jr All D NA 144 ('.'JUF '08, N P�' � A rR 'Wr" CW -MS W i6ri, 56P 6C."M 40P, NM S, 12P S,­ "i , 'wp.k. Cs6l) (MFP/Nff� CS�,W 049HCtrenc 1 -41C M& 56X V C sx P, C_"X_M'6 G 1-14H(F M10 SL iijw& L! 151`11.612 '14 CMSMll:w 1!c T05 ".%'Pl Mil FFT61,; J;H CSG ! 5 4T14 H -"r(M o1 Cssi 60TT4 11 SAAE 'n,' 1 �6�-C, 1477?_'�SfiPIVI-C CS 6 1-72TS-11 'I �_ —71 T7 ­S6M0')'-fF AM10610" . ........ . I & HT72-=6,,"' HT;'?-Iry MUM ­0 C I ' Hyp 'F­ �0'€ Ht-DH140-> C I­r 1­04. C I— HCI 1FIJ4 rR '­-qY) HYOH"b F. ;2a C -us'cl 11104WICIL-Url "Y DWWs, rLIC11 jj_'_j6 KC. MG, RV.TG,RrR1, fl. K;, III OrionEw "Wo & Apolla 1000 _MR1 ".wqy Hr­d r H's Da­",z S.1a, SSH­1110-72HUD il ScIi�' F I A� MWIIM s r ':10WW,4V9 His :,­YH$K,. Hi5-s',"xrIrW XX<S H-H1-* 1, Ln' 66HGIr ki Rt!c H HC -The frame profile must not have any feature that might interfere with the bonding devices that are integrated into The rocking system N • Use with a maximum over current protection device OCPD of 30A • Unless otherwise noted, all modules listed above include all wattages and specific models within that series, Variable wattages are represented as 'xxx'* • Items in parenthesis are those that may or may not be present in a compatible moduhs s model ID • Slashes 'Tbetweer one or more Items inckates that either of those trams may be the one that is present in a modules model ID • Listed models can be used to achieve a Class Afire system rating, for steep slope or low slope applications, only when modules of fire typed mentioned in Appendix A, Page 27 are used. • PAGE M 0 "us NT COMPATIBLE MODULES: ----------------- ------- --------------------- -------------- ---------- ------------ Electrical Bonding and Grounding Test Modules The list betow is not exhaustive of compliant modules but shows those that have been evaluated and found to be etectricaRy compatible with the NXT MOUNT system, marld.m,. wdle M.Wi / Series M.,"xt— Md.W Wad S., 5 11- SH 00 LIM. 40 Yt 1 LS-11 K�! S6r, B—ir-, Ll,.VL, LS— HC, I 'SP MA, 3-sxxdnrt 1IMS HC S.— (Ml O-W 08M M,-'. Wk-MAX:� I'll —14166) SPH-MAX,XAX-8LK-K TrK iT �F k-&- As Hi.-- E r Burge. Stack. 13.19 vrnne Ls-01C`141 �. r� lcvIK,1 CQ1 1 UHL�Zr�� q", gunge-GI-5 wv, l jps-6f', & fps- ,, 5, QAUQAK)'Au, 1_E5,jS'_r; 11K.W. V—JISt P— A115 , -,I —;hIR If `v2 C, mi -- Sm, MSE .. JRl 1,SRU'SRJS:SX5 I l M i .4 (IMP 3 : JAW/150,IR JA16 60 IS mi-b 13-1 SHY— I'll A S—, JAP?25#---" IS �AP(A,x--VQBJAP�0,q*a-, , LGx-INAN6 A'I JAM'' t fn-W,tHP�HPH) 1fiMLR4� 'LRy- Q(HP�41 012, 01 09, 10 jf- LYW 29 L —7, 110 sc, 'r, ap� iri t, I8, my, MR L RS " HP8 I NFF ,,, WMH 116 - CAI 7 'HO rk S.W, nM XXX KW, & JKMS S,ade R 60 `i:�FXYX— Hr Mir, � ioNci LR6 60IMMPS, HPH!W:,F-WETH) "a F e xx H a - Y I jr,lx4- LR6 7? 1 K M 77HPA -V, S(11— '1 -72 HI 06 7 2tBKN\. PWPE;Vuj 5" 1Kuxxxr 10-0[7 LR7 7?HCD — F1 JKM_ i RP,-6(,IICD-Xxx M P.'—, VllH149YYSA:?.'SA I !7U;AIvSA!?F. Ik line1.'1i-i KL r-1 V LR4-QHPB YHWN—ZA01,'.;0? 'AO/i!HN-2,104 KD t e, Fil R,,,IBWk LR6-6'r,,P9 rvp— o - P—OSKiN /HKIHW:. The frame profite must not have any feature that might interfere with the bonding devices that are integrated Into the racking system • Use with a maximum over current protection device OCPD of 30A • Unless otherwise noted, att modules listed above include all wattages and specific models within that series. Varlabte wattages are represented as 'xxx- Items in parenthesis we those trial may or may not be present in a compatible modutes model ID • Stashes "I" between one or more items indicates that either of those items may be the one that is present in a module's model ID Listed models can be used to achieve a Class Afire system rating, for steep stope or tow slope apiatkations, only when modules of fire typed mentioned in Appendix A, Page 27 are used. DESIGN ENGINEER LING 76 N. MEADOWBROOK DRIVE ALPINE LIT 84004 cwn 1201 I 87,4-3463 • DESIGN ENGINEER WYSSLING COMPATIBLE MODULES �W 76 N. MEADOWBROOK DRIVE I ALPINE LIT 84004 U Mku mo" NT' cwn PAGE t201 i 874-346? ------------------------------------------------------------------------------------------------------- * --------------------------------------- Electrical Bonding and Grounding lest Modules The list below is not exhaustive of compliant modules but shows those that have been evaluated and found .a be electrically compatible with the NXT UMOUNT system. M...f.. M.WW. Mtidtai / W- M­f�,� Module MWd/S­ QPFAV QUQ ( _(U,;c7j /G7' , r- 3,c� "71 RU­ RSM S,:­ Fis rl 11 C� S RnDE N-v", 5`5 KI.­14 QPFAK DUO I -,68,6S I!G3_7!6MI ittc­ 81rq HY KR, » x KPD IR QFF:XRUO f -R6 i; RIC, o prllll� DUO L-GS 'jRFr,,HFcrr0T) 51(. XXX.r,1R TV, SFr W4 ir. Q PFAI QUO '�Ec­ 0',H D'I PC fi46 PC, 86S' QPFAP SEG 91A � -_c 813 RG S­P14i"' 141N QFLAI, DUO 2,,09:t 5Lr 5119 BG, SLC ­ 8 1' , RO; -Q!UH Q P L A D DO XLOACT 5 TERQ 5, 4 !' L i"Nvc S,­., ZO L'H QPLAN OUOXL-tA01V5F6, 5-r­PY PS, It , 41�' 0 PEAK DUO YL (A I i,DIIG SL4-60116, Ps­!P1_24/T Q PEAK D' 10 11 - 1, 115 51�,- rPkPR`6t1W6k1A rI1`!6,M8/1,01L,cIT; rv­M. 24"'M oprw DUOYL Gtl5 3,'BFG S101 Ia2k"QrK QPrAPDUOKt, 69343rG SRI' I SMP UY ',RP 570 il5 WK vN ltf,­Pf'x xxx Q TRON M K M G-'- At- IRP 9 "r IP,qll'p '5::, sSo pt`"" 11 Peak Q:r1PTURtK1I V,*SFRWI SRI` 3ML 1,1,, SMI-PO 40, IDJ) PeL-G5 C, �-, -cs(BM EON M0`SERIES A 1�0 SA x. NU 5( P P �IPWNSnare5,p "i'P',, 'P. n A -M 2, P­4 I C21 1 -C4, I -v' R�cx> 1,V, t6LI,vtIrAT-­ R-f Kurt, RV PUKe , q A R 11 t� 1 ,1 1 r� I',, !It S1, QXAK UW EL".) 111�� 2" r,� fa}S tfa,, �1L­18VdKAILMQW,, Ht,`H!-J,UU,`PIL N 1AK DkIC E, 0-6) RV­NP jN-PTAK, t, LAN T11MX N U/QD: Q111.j V 'A, DI 10 zHt"11; G..A( 4A 1)14HW I �HL�L M�: 5 C ,!!t QP A< DIX; Ri 0,tr�� P-k S,�x,IA ....... 4A:­ IIPsA. DU00 k; ML U Rfr RH-­PF. RrC-,Pl 7,1 i4A, I, :44FHI UPLA,i DOOPIK 1„cz+l RFC-,TP, FEC,.TP7', ­A1­1WTH10:­ 61 RC­TP,1; St. 1v6'55­,r4 120'tt 0 PW, DLIO R1,N USA 5E IS2-91 10FN nPEAKI)IJO 8LF. -,L G10 I qtm(­I11114;8Ir+riIj QPEA< DUD ELK HL C, jOt.1 IS kV1­rP4 I81at ki ­P. I c _4HcC=, 0 NIAti, DUO GVDI ket,P<­ A; I 60­U Pt -The frame profile must not have any feature that might interfere with the bonding devices that are integrated into the racking system • Use with a maximum over current protection device OCPD of 30A Unless otherwise noted, all modules listed above include all wattages and specific models within that series. Variable wattages are represented as 'Xxx" Items in parenthesis are those that may or may not be present in a compatible modules model ID Plt;,� 1^. Slashes 7" between one Or more items indicates that either of those items may be the one that is present in a arodute's model ID Listed models can be used to achieve a Class Afire system rating, for steep slope or tow slope applications, only when modules of fire typed mentioned in Appendix A, Page 27 are used. 1U'M0'U-'NT: COMPATIBLE MODULES:* PACE ---------- ------- - -------------------- - ------------- ---------------------- ------------------------------------- Electrical Bonding and Grounding Test Modules The list below is not exhaustive of compliant modules but shows those that have been evaluated and found to be electrically compatible with the NXr UMOUNT system, M.Ww— I 1 Wftke modO / S.6- Wpubo— Modute Nadel / wrics M..Na.. Wd.t. Model t Se,*. P—YT,-R (AUID.Gnl 13-05 D[09-0,' D[01111-G" VNs' 2M- -5 "Av 15. DEGI ST, --st X V N S " 2M � 5 - x W" 15, SolariaP—Xr-"'R PM IACI D" IS,( c 2�1 Z W1 5, P�,,- � �00R DC'S. DEC VIC 20 S � I I *R( PtD' T"'a P`0,. PDOS. DDC&DD04 111—IC1113, —W I.C' PP14 VSA.' 6crr 3FNS'0N— 11"M rs "i -D ur 10 $, T 5 M D F1 I C '544 OF 17'0, 5s r, {Eo rY `59c N'41RC M ,.4SMN, VSa1i,1611-: !:C, 393 4 1--, ISM V5D' 109M 98 vsON", 12CBM, S""Ai �M a S—s N— I-SWR NF-- 141,44 5- Ed;w': r 5'—" P, 3e' es UNi4x,I44B4`, D UNE' 5-1,140'41H DC V'UN r1H V �" 'N.—I 4•�ffl D,' M, Sr"s I, ODI,— svw� ISON 'SJN: i4dm-fu�*.YSUN— 44M,--rB 1 Pi<SH-R,3 Q011-tr; vS r23W! As X wr'5'F�sv- " Dse'- Wsr & Y's. 5.11., 'sPEu)4" OV. 'C 4 trams) uas.L;r 0 M..R UP M—My' I,) -aLX A(,SPR �Y-��H-A, 07K(7sA)-r?MWAI� Y�ngt: D" "4 Emly YSr' B450 1 urirth 5;'sl URECO W-17'-BB M651TI'660 is""g, I u"I,D �' v-q as ZY116 N:%DD)44,ZY.147�9110vSo,es TD 172r"'Tpn;""Ji! 7XI17-UP DD144 V AAAV; �RF�Xc"-"SVO-b. 75 B6,4 the frame profits must not have any feature that might interfere, with the bonding devices that are integrated into the racking system • Use with a m8 x irnum over current protection device OCPD of 30A Unless otherwise noted, ail modutes listed above include all wattages and specific models within that series, Variable wattages are represented as"xxx' Items in parenthesis are those that may or may not be present in a compatible modute's nmdet ID Stashes */ " between one or more items indicates that either of those items may be the one that is present in a modure's model ID • Listed models can be used to achieve a Class A fire system rating, for steep slope or Low slope applications, only when modules of fire typed mentioned in Appendix A, Page 27 are used. DESIGN ENGINEER WLING � Y- 76 N. MEADOWSROOK DRIVE ALPINE UT 84004 smysoing @wyss4n?groor) 5u*ig corn 1201 ! a74.3483 •