Loading...
HomeMy WebLinkAboutSFRA2024-003748ADDRESS 110 Ivy Glen Dr. Grapevine, TX 76051 LEGAL Silver Lake Addition Blk 1 Lot 40 S PERMIT HOLDER Gary Gietz Energy Services Partner s Texas (682) 204-5521 COLLABORATORS •Gary Gietz Energy Services Partners Texas (682) 204-5521 OWNERS •Tigner, Amy INSPECTIONS 1 1. Building Final INFORMATION FIELDS **APPLICANT NAME (Individual)Chelsea Mercurio **APPLICANT PHONE NUMBER 9252077048 VALUATION 23838 * CONSTRUCTION TYPE VB * OCCUPANCY GROUP R-3 DOCUMENTS - MISC 01 APPLICATION.pdf DOCUMENTS - MISC 02 CONSTRUCTION PLANS.pdf * ZONING DISTRICT R-5.0 APPROVED TO ISSUE ELECTRIC YES FEE TOTAL PAID DUE Building Permit Fee, ($150.00 Flat Fee) Simple Alteration $ 150.00 $ 150.00 $ 150.00 TOTALS $ 150.00 $ 150.00 $ 0.00 READ AND SIGN I HEREBY CERTIFY THAT THE FOREGOING IS CORRECT TO THE BEST OF MY KNOWLEDGE AND ALL WORK WILL BE PERFORMED ACCORDING TO THE DOCUMENTS APPROVED BY THE BUILDING DEPARTMENT AND IN COMPLIANCE WITH THE CITY OF GRAPEVINE ORDINANCE REGULATING CONSTRUCTION. IT IS UNDERSTOOD THAT THE ISSUANCE OF THIS PERMIT DOES NOT GRANT OR AUTHORIZE ANY VIOLATION OF ANY CODE OR ORDINANCE OF THE CITY OF GRAPEVINE. I FURTHERMORE UNDERSTAND THAT PLANS AND SPECIFICATIONS ARE NOT REVIEWED FOR HANDICAPPED ACCESSIBILITY BY THE CITY AND THAT THE DESIGN PROFESSIONAL / OWNER IS RESPONSIBLE FOR OBTAINING SUCH APPROVAL FROM THE APPROPRIATE STATE AND OR FEDERAL AGENCY(S). October 21, 2024 City of Grapevine PO Box 95104 Grapevine, Texas 76099 817) 410-3166 Building - Residential Alteration Project # 24-003748 Project Description: installing a new 6.98 kw pv system with a Enphase IQ Battery 5kWh, w/ Cover Kit Issued on: 10/21/2024 at 10:53 AM MYGOV.US 24-003748, 10/21/2024 at 10:53 AM Issued by: Victoria Hecko Page 1/2 October 10, 2024 PV Letters Proposed Solar Panel Installation Amy Tigner Residence 110 Ivy Glen Drive, Grapevine. TX PV Letters Job -001-0884 To *Whom it May Concern, We have reviewed information, provided by our client. related to the proposed solar panel installation at the above -referenced address. The purpose of the review was to determine if the existing roof is structurally adequate for the proposed installation. Based on our review and analysis of the given information. and ill accordance with governing building codes. I certify that the capacity of the structural roof framing that directly supports the additional gravity loading due to the solar panel supports and modules had been reviewed and determined to meet or exceed the requirements in accordance with the Design Criteria. Site survey completed by ESP Texas. . .. .. ...... ___ .............. .... .. . . ... Desien Parameter Stumnati- Governing Building Code: 1-0-11 International Residential Code (IRC) Risk Category,: 11 Wind Exposure: C Design Wind Speed: 107 nipli Ground Snow Load: 5 psf Roof Information Roof Suncture: 2x6 Rafters Zi 24" O.C, ( assumed ) RoofingMaterial: Asphalt Shingles Roof Slope: 3" degrees PAG�� riEU-, 3� FCR (--0,,`!STP,UCTN0t,5 r`fffAPPF','0V-E[) Fi.,ANS 'CC) aE �CEP` QN 7-HE $I f E'A"' , F AIA. F0,YPR, A TE: 10 5 C24 SY7 YV, Sco�t 'SIBP, 214 C A, t.r T, Roof Connection Details A L C '1, 1, 4,,; E ' s V, L I S' S, PP � R� 0 V E R L ag Screws i I screlkN% 5 � 16" dia urin., xvith min. 2 � 5 " embedment into rafter olity. at 7 2 " 0. C. . ......... . -2, Stagger attachnients to avoid overloading any individual rafter. Enainecrina Analysis The proposed installation - including weight of panels. racking, mounts, and inverters where applicable will be approximately psf. In the areas where panels are installed, roof live loads will not be present. The reduction of roof live load is adequate to fully or partially compensate for the addition of the panel installation. Because the member forces in the area of the solar panels are not increased by more than 5116, and so per provisions in the adopted building codes. the structure need not be altered for gravity loading. The proposed installation will be 6" niax. above the roof surface (flush mounted) and parallel to the roof surface. Therefore. any increase in wind loading on the building structure from the solar panel installation is expected to be negligible. Wind is the governing lateral load case. Because the increase in lateral loading is not increased by more than 10066 per provisions in the adopted building codes. the structure need not be altered for lateral loadin2. Wind uplift on the panels has been calculated in accordance with the relevant provisions of ASCE 7-16, This loading has been used to verify the adequacy of the connection specified above. Connection locations should be in accordance with design drawings. Everest K2 Systems Crossrail 44-X rails will support the modules and will fasten to the roof stmeture with Everest K-1 Systems EverFlash XP L-Foot along the rail. Conclusion The roof structure need not be altered for either gravity loading (including snows or lateral loading (including wind), Therefore, the existing structure is permitted to reniiin unaltered. Connections to the roof must be made per the "Roof Corurection Details" section above. Copies of all relevant calculations are enclosed. ['RECEIVED: 10/14/2024 24-003748 110 IVY GLEN DRIVE INSTALL SOLAR PANELS Limitations and Disclaimers The opinion expressed in this letter is irrade in reliance on the follovv'ing assumptions: the existing structure is in good condition; the existing structure is free from defects in design or workmanship: and the existing structure was code-contpliant at the time of its design and construction, These assumptions have not been independently verified, and we have relied on representations iriade by our client with respect to the foregoing. The undersigned has not inspected the structure for defects. although we have reviewed the information provided by our client. including pictures whereapplicable. Electrical design is excluded frown this analysis, Waterproofing is tire sole responsibility of the installer and is also excluded front this analysis. Solar panels must be installed per manufacturer specifications, Structural design and analysis of the adequacy of solar panels. racks, mounts. and other components is performed by each componerit's respective manufacturer, the undersigned makes no statement of opinion regarding such components. This letter and tile opinions expressed herein are tendered solely for tire benefit of the permitting, authority (city or county building department) and your office, and may not be utilized or relied on by any other party. If you have any questions or concerns. please contact nie at Q108)-994-1680. or email me directly it Trevorapvletlers.colri. Sirrcefely� Trevor A. Jones, P.E. 10 IW20-14 4� TiiV6R -jomi. 144080 WA � ............. ........ ........ ........ ........ ........ ........ ........ ........ ........ ........ ........ ........ ........ ........ ........ ........ ....... TH�S PAGE REi-EASEO RU C TKAN PV I Letters Standard Loading Comi)arlson This calculation justifies the additional solar load by comparing existing to proposed gravity loads in the location of the solar panels. Dead Load Asphalt Shingles 1/ " Plywood Framing Insulation 1/2" Gypsum Ceiling M,E, & Mise Solar Panel Total Dead Load Snow Load Ground Snow Load. P. Exposure Factor, C, Thermal Factor, C, Importance Factor, 1, Flat Roof Snow Load Slope Unobstructed Slippery Surface? Slope Factor, C', Sloped Roof Snow Load Live Load Roof Live Load Load Combination D — Lr D+S -Max. Load Q,'O' of original Result: Without Solar With Solar 5 5 2 0 5 1.00 1.1 1 4 37 No No 1.00 1.00 3.9 3.9 20 0 psf *-sc f . ............................................ Ti-413 PAGE RELEASED FOP, 71 n LANS TO S 2 P T CNI Tli'E- j00 S�M AT ekLL TMIES, ALL 'ZHAM';3,FS 'A k, S 8C- APPPIW��D . . . .... .. ...... ....... .... .. ..... . ... ........... . ASCE 7 Erin. 7.3-1 orjurisdiction an. degrees M 28.0 11.0 psf 1 11.9 14.9 Ipsf F- 28.0 14.9 Ipsf 53.04% Because the total forces are decreased, per the relevant code provisions stated in the body- of the letter, the existing roof structure is permitted to remain unaltered. 44 PV Letters Lai! Screw Calculation tper ASCE 7-16) This calculation justifies the connection of the solar panels to existing roof inembers, by showing the connection capacity is equal to or greater than the uplift force denialids. Z7 Connection Demand Spacing perpendicular to rail. in Roof Angle, degrees Roof Layout Wind Speed. niph Exposure Coefficient, K, Topographic Factor. K, Directionality Factor. Kd Elevation Factor, K, Velocity Pressure q, psf Spacing parallel to rail, in GCP (niax) Exposed Panels? (YE = 1-5) Effective Wind Area oil each coca", it - Pressure Equalization Factor, 't, Uplift Force, psf Max. Uplift Force ' Conliection (0.6 'AIL), lbs Solar Dead Load (0.6 DL). Lbs Max. Uplift Force (0.6 WL - 0.6 DL). lbs Connection Caqjjjtv Attachment FTG Atticlunent location Fastener Type Fastener Diameter, in Embedinent Length. in Lumber Species & Grade Nominal Withdrawal Capacity W. lbs it of Screws Load Duration Factor Cj Screw Adj. Withdra, Nval Cap. W', lbs Attachment FTG Strength with Cd. Ibs Max applied load, lbs Max allowable load. lbs 21 37 Hip 107 0.85 1.00 0,85 0.98 207 I 2r, 2e 3 72 72 72 135 ------------ -- 1,79 2.09 No Zia 1~30 10.3 10.3 10.3 0.80 0.80 0.80 22,2 29.4 34A 137.0 181.3 212.4 18.5 18.5 j 18.5 118.5 162.8 193.9 Everest K2 Systenis EverFlash XP L-Foot Framing Lag Screw '��Y OF GRAPEVPIZ T`MS FAG,��' RI-1EA11"IED ��OR 03125 2.5 SPF #2 ( Assumed ) 6 512 O8TY APFIPOVEC) PUMNS SE KEPT ON THE JOH AT ALI. 8, 1.6 819 T CA`r-, —960 194 819 CqHMAj±,Aqj!jsted Withdi,awal Capacitv, to ASD Factoi-ed Demand Zones: I 2r, 2e 3 ..... .. .... . 17 MODULES —ROOF MOUNTED ! i.93 1 GRAPEVINE,110 IVY GLEN DR, 78664 SYSTEM SUMMARY: CONSTRUCTION NOTE: (N) 17 - HANWHA Q.CELLS Q.PEAK DUO BLK ML-G10+ (41 OW) MODULES A LADDER SHALL BE IN PLACE FOR INSPECTION (N) 17 - ENPHASE ENERGY IQ8PLUS-72-M-US MICRO -INVERTERS THE PV MODULES ARE CONSIDERED NON-COMBUSTIBLE AND THIS (N) JUNCTION BOX SYSTEM IS A UTILITY GRID INTERACTIVE SYSTEM (E) 200A MAIN SERVICE PANEL WITH (E) 200A MAIN BREAKER A GROUNDING ELECTRODE SYSTEM IN ACCORDANCE WITH NEC ( N} 100A FUSED VISIBLE LOCKABLE dPEN LABELED AC DISCONNECT WITH (N) 690-47 AND 250-50 THROUGH 60 250-166 SHALL BE PROVIDED PER FUSES, VAG (N) ENPHASE ENERGY IQ COMBINER BOX 5/5C NEC. GROUNDING ELECTRODE SYSTEM OF EXISTING BUILDING MAY (N) ENPHASE ENERGY IQ BATTERY-5P-1 P-NA BE USED AND BONDED TO AT THE SERVICE ENTRANCE. I F EXISTING (N)125AMP SOLAR LOAD CENTER SYSTEM IS INACCESSIBLE, OR INADEQUATE, OR IS ONLY METALLIC WATER PIPING, A SUPPLEMENTAL GROUNDING ELECTRODE WILL BE EXISTING SYSTEM SUMMARY: USED AT THE INVERTER LOCATION CONSISTING OF A UL LISTED 8 Fr GROUND ROD WITH ACORN CLAMP. GROUNDING ELECTRODE (E) 23 - SPR-E20-327-E-AC MODULES CONDUCTORS SHALL BE NO LESS THAN #8 AWG AND NO GREATER (E) 23 - IQ7XS-96-ACM-US M ICRO-INVERTERS THAN #8 AWG COPPER AND BONDED TO THE EXISTING GROUNDING (E) JUNCTION BOX ELECTRODE TO PROVIDE OR A COMPLETE GROUND. (E) 60A FUSED VISIBLE LOCKABLE OPEN LABELED AC DISCONNECT WITH 40A FUSES. 240VAC USING THE ED EACH MODULE WILL BIDENTIFIED {E} 126AMP SOAR LORD CENTER ior ;`pi�.OF TES liii ROUNDING POINTS BDY THE MANUFACTURER. tt ° * �UTILITY METER NO: 129 835 954 ( / * : * t EXPOSED NON -CURRENT CARRYING METAL PARTS OF MODULE IESIIDND:1044------------5 L Yuh 4-0-I S f FRAMES, EQUIPMENT, AND CONDUCTOR ENCLOSURES SHALL BE ! DESIGN CRITERIA: GROUNDED IN ACCORDANCE WITH 250.134 OR 250.138(A) REGARDLESS OF VOLTAGE. SHINGLE";CtCENSEO: �� ROOFSTORY ONE STORY ." SNOW LOAD 5 PSF ii PROPER ACCESS AND WORKING CLEARANCE AROUND EXISTING AND PROPOSED ELECTRICAL EQUIPMENT WILL BE PROVIDED : - 14i1^' WIND SPEED :-107 MPH WIND EXPOSURE: G J ett ors uC ALL SIGNAGE WILL BE INSTALLED AS REQUIRED BY AND 2020 NEC. EXPOSURE CATEGORY:- II r -' rm Nd , - i 4 6 9 GOVERNING CODES: StrUGtUral Only 10l1012024 HEIGHT OF INTEGRATED ACIDIC DISCONNECT SHALL NOT EXCEED 6' 7" PER NEC 240.24 2021 INTERNATIONAL BUILDING CODE (IBC) 2021 INTERNATIONAL FIRE CODE (IFC) THE GROUNDING ELECTRODE CONDUCTOR SHALL BE PROTECTED 2021 INTERNATIONAL ENERGY CONSERVATION CODE (IECC) FROM PHYSICAL DAMAGE BETWEEN THE GROUNDING ELECTRODE 2021 INTERNATIONAL RESIDENTIAL CODE Ill AND THE PANEL (OR INVERTER) IF SMALLER THAN #6 AWG COPPER 2021 INTERNATIONAL SWIMMING POOL AND SPA CODE (ISPSC) WIRE PER NEC 250-64B. THE GROUNDING ELECTRODE CONDUCTOR 2021 INTERNATIONAL MECHANICAL CODE (IMC) WILL BE CONTINUOUS, EXCEPT FOR SPLICES OR JOINTS AT 2021 INTERNATIONAL PLUMBING CODE (IPC) BUSBARS WITHIN LISTED EQUIPMENT PER NEC 250.64C. 2023 NATIONAL ELECTRIC CODE (NEC). Tc�ar;:,t��:ata =�aurs ALL EXTERIOR CONDUIT SHALL BE PAINTED TO MATCH ADJACENT SURFACES. Nr> it ,r.L t.T „ NIA THE PV CONNECTION IN THE PANEL BOARD SHALL BE POSITIONED SHEETINDEX "'aslTe. AT THE OPPOSITE (LOAD} END FROM THE INPUT FEEDER LOCATION PI COVER SHEET OR MAIN CIRCUIT LOCATION. NEC 690.64(BX7) -PIE''�' PV-1 SITE PLAN WITH ROOF PLAN `... SITE CONDITIONS SHALL PREVAIL IF NO SCALE IS GIVEN. DRAWINGS = .�:�', '•-�-e` PV-2 ROOF PLAN WITH MODULES � ARE NOT NECESSARILY TO SCALE. ALL DIMENSIONS SHALL. BE e• t PV-3 ATTACHMENT DETAILS - PV-3.1 ELEVATION DETAILS « VERIFIED BY SUBCONTRACTOR UPON COMMENCEMENT OF GONSTRUGTIgN. - PV-4 SINGLE LINE DIAGRAM PV-41 THREE LINE DIAGRAMc4---- PV-5 ELECTRICAL CALCULATION PV-6 PLACARDS & WARNING LABELSt -p - - -: - - PV-7+ SPEC SHEETS •- sealed 100CU024 Mike§h2dc com- .,,...,,..-''; H2DC PLLC TX COA# F-20725 ELECTRICAL ONLY .... NOTAN AS BUILT DRAWING SET 1 AERIAL PHOTO PV-0 SCALE. NTS PROJECT SITEto -- t lli Sit 1151 110 Ivy Glen r, Grapevine, TX 7651, United States �r" (r1 1Q 2 VICINITY MAP w s PV-0 SCALE NTSIII CONTRACTOR ESP TEXAS 1214 E BELT LINE ROAD UNIT 450 DALLAS, TX 75234 MASTER ELECTRICIAN MIKE ALVAREZ. LICENSE N 667850 SIGNATURE WITH SEAL REVISIONS REV DESCRIPTION DATE DATE 10,5Q_'�24 PR7jECT NAME UU z rr-ti? > Lu Z W P O I— Z © 0 O Q L z f,C I <U 0 SHEET NAME COVER SHEET SHEEN SILE ANSI B 1VX17" SHEET NUMBER PV-0 MODULE TYPE, DIMENSIONS & WEIGHT NUMBER OF MODULES = 17 MODULES MODULE TYPE = HANWHA O.CELLS QPEAK DUO BUK ML-G1 O+ (41OW) MODULE WEIGHT = 48.5 LBS 122.0 KG. MODULE DIMENSIONS = 74ffX 41,11" = 21.12 SF UNIT WEIGHT OF ARRAY = 2.30 PSF PLUMBING VENTS. SKYLIGHTS AND MECHANICAL VENTS SHALL NOT BE COVERED, MOVED, RE-ROUTED OR RE -LOCATED. NOTE: iA ALL ELECTRICAL EOUPMENT, INVERTERS, DISCONNECTS MAIN SERVICE PANELS, ETC SHALL - NOT BE INSTALLED WITH N TOP THE (3AS METERS' SUPPLY OR DEMAND PIPING, ROOF #1 (17) HANWHA BQ.CELLS O-PEAK DUO ILK ML-Gio+ (41OW) MODULES 2'-JR SITE PLAN WITH ROOF PLAN SCALE. 1124"=V-0' I I UTILITY METER NO: 129 $35 954 1ESIIDNO:10443720008008735 VILLE) LOCATED CINACCESS19LE EXTE1R1CRvNAUVATHIN OFONCORMETER -49621 PROPERTY LINE J o 141111 C�) c\1 "o Luf 0 V_ _!4 M. ROOF ACCESS POINT: SHALL BE LOCATED IN AREAS THAT DO NOT REQUIRE THE PLACEMENT OF GROUND LADDERS OVER OPENINGS SUCH AS WINDOWS OR DOORS, AND LOCATED AT STRONG POINTS OF BUILDING CONSTRUCTION IN LOCATIONS WHERE THE ACCESS POINT DOES NOT CONFLICT WITH OVERHEAD OBSTRUCTIONS SUCH AS TREE LIMBS, WIRES OR SIGNS. ROOF ACCESS POINT INVERTER & MODULES DETAILS 17) ENPHASE ENERGY INVERTER 108PLUS-7241-US (17) HANWHA Q CELLS 0 PEAK DUO PV MODUI-ES BLKML,G10+(41OW) oc-, , 0, D 00 (N) 3/4" OR GREATER EMT CONDUIT RUN (1/2 INCHES ABOVE ROOF) ONE� S7-ORY -- -------- (E) 23 - SPR-E20-327-E-AC MODULES HOUSE (E)GATE (E) FENCE 0 7 1 A GL r L E m -HI Ilk m A -53.04 v SI_ S Y; �i' sealed 13od2024 mikee-112CIC Mm H2DC PLLC TX CoAP F-20725 ELECTRICAL ONLY NOT AN AS BUILT DRAWING SET LEGEND i ONCOR METER MAIN SERVICE PANEL ACD _ACDISCONNECT jSLC SOLAR LOAD CENTER s. CB COMBINER BOX 5 IJEJ JUNCTION BOX BAT -BATTERY CONTRACTOR ESP TEXAS '214 E BELT LINE ROAD UNIT 450 DALLAS, TX 75234 MASTERELECTRICIAN MIKE ALVAREZ LICENSE 9 667,850 SIGNATURE WITH SEAL REVISIONS REV DESCRIPTION DA*tE DATE INOD2024 NAIVE o It- rr CL LU Z X 0 < z w P () x z cl) 0u_ F- (D wz 2i > LU z < EL < 4i < SHEET NAME SITE PLAN WITH ROOF PLAN SHEET SIZE ANSI 6 11" X 17" SHEET NUMBER Pv_1 MODULE TYPE, DIMENSIONS & WEIGHT NUMBER OF MODULES = 17 MODULES MODULE TYPE = HANWHA CLCELLS Q.PEAK DUO BLK ML-G1 0+ (410W) AREAOF MODULE WEIGHT = 48.5 LBS / 22.0 KG. NEW ARRAY MODULE DIMENSIONS = 74.0"X 41.1" = 21.12 SF (Sq, Ft) UNIT WEIGHT OF ARRAY = 230 PSF NPTE: 36" FIRE PATHWAY INTERNATIONAL FIRE CODE SECTION 120421 PATHWAYS TO RIDGE, NOT FEWERTHAN TWO 36-INCHWIDE (914 MM) PATHWAYS ON SEPARATE ROOF PLANES, FROM LOWEST ROOF EDGE TO RIDGE, SHALL BE 18" FIRE PATHWAY PROVIDED ON ALL BUILDINGS NOT FEWER THAN ONE PATHWAY SHALL BE PROVIDED ON THE STREET OR DRIVEWAY SIDE OF THE ROOF. FOR EACH ROOF PLANE WITH A PHOTOVOLTAIC ARRAY, NOT FEWER THAN ONE 36,INCZDE ARRAY AREA & ROOF AREA CALC'S AREA OF AREA OF NEW AREA OF TOTAL ROCr VULD LOCATED cN ACCESSIBLE � 4 EXTER0RV\ALLVVTHN!I: I OF ONCOR METER I ROOF DESCRIPTION ROOF TYPE COMP SHINGLE RO 0 F EXISTING ARRAY Sq Ft) & EXISTING ARRAY (Sq FL) ROOF(PLAN VIEW) (Sq Ft.) AREA COVERED BY ARRAY T. UTILITY METERNO: 129835 9541 ESIID NO:10443720008008735 ROOF ROOFj TILT AZIMUTH 37- 280- OFRAFTERS RAFTERS ODU MODULES SPACING 17 . 2'X5" 24" 0 C 443,54 802 59 2634 3047% (914 MM) PATHWAY FROM LOWEST ROOF EDGE ROOF #1 TO RIDGE SHALL BE PROVIDED ON THE SAME (17) HANWHA Q. CELLS QFEAK DUO ROOF PLANE AS BLK ML-G1 0+ (41OW) MODULES THE PHOTOVOLTAIC ARRAY, ON AN ADJACENT ROOT PLANE OR STRADDLING THE SAME AND ADJACENT ROOT PLANES. (N) (46) K2 SPLICE FOOT ATTACHMENTS SPACED AT 72" O.0 1204 2, 11 SETBACKS AT RIDGE FOR PHOTOVOLTAIC ARRAYS OCCUPYING 33 PERCENT OR LESS OF THE PLAN VIEW TOTAL K2 CR44X RAIL ----- - ROOF AREA, A SETBACK OF NOT LESS THAN 18 INCHES (457 MM) WIDE IS REQUIRED ON BOTH SIDES OF A HORIZONTAL RIDGE FOR (E) 2'X6" RAFTERS ( -"la 24" C.C. (TYP.) V PHOTOVOLTAIC ARRAYS OCCUPYING MORE THAN 33 PERCENT ENPHASE ENERGY IQ8PLUS-72.M.US OF THE PLAN VIEW TOTAL ROOT AREA, A SETBACK OF NOT LESS THAN 36 INCHES (45 MM) (N) INVERTER WIDE IS REQUIRED ON BOTH SIDES OF A HORIZONTAL RIDGE BRANCH#I GAS METER LOCATED IN PROX;MITY OF THE PV INSTALLATION, LOAD CENTER, ANDIOR DISCONNECTS. DISCONNECTS SHALL BE LOCATED IN COMPLIANCE WITH UTILITY AND THE AHJ (AUTHORITY HAVING JURISDICTION) PV INSTALLATION SHALL 4 COMPLY WITH ALL APPLICABLE CODES. THE WORKING CLEARANCES AROUND THE EXISTING ELECTRICAL EQUIPMENT AS WELL AS THE NEW ELECTRICAL EQUIPMENT WILL BE MAINTAINED IN BRANCH#2 Q� peep ACCORDANCE WITH NEC 110,26, NOTE • PLUMBING VENTS. SKYLIGHTS AND MECHANICAL VENTS SHALL NOT BE COVERED, MOVED, RE-ROUTED OR RE -LOCATED, • ACTUAL ROOF CONDITIONS AND RAFTERS (OR SEAM) LOCATIONS MAY VARY. INSTALL PER MANUFACTURER(S) INSTALLATION GUIDELINES AID EfIGIREERED 2�,�41S FOR ATTACAITERTS. Z ROOF PLAN WITH MODLJLESA� SCALE: 3/32" = V-0 (17) HANWHA Q.CELLS QPEAK DUO ELK ML­G10+ (41OW) MODULES (17) ENPHASE ENERGY IQ8PLUS-72-M-US MICRO INVERTERS (01) BRANCH OF 09 MODULES & GLEN\DR (01) BRANCHES OF 08 MODULES CONNECTED IN PARALLEL r\-ONT rA[m\D (N) 3/4" OR GREATER EMT CONDUIT RUN (7/8 INCHES ABOVE ROOF) CIRCUIT LEGENDS (E) 200A MAIN SERVICE PANEL CIRCUIT #1 WITH (E) 200A MAIN BREAKER CIRCUIT #2 (E) SOLAR LOAD CENTER 'A (E) FUSED AC DISCONNECT 11\� E, A R \KAR0 N CONTRACTOR m ESPTEXAS 3214 E BELT LINE ROAD UNIT 450 DALLAS, TX 75234 MASTERELECTRICAN MIKE ALVAREZ LICENSE # 667850 SIGNATURE WITH SEAL REVISIONS REV DESCRIPTION DATE DATE INOD2024 (E) ONCOR METER (N) 100A FUSED VISIBLE LOCKABLE OPEN LABELED AC DISCONNECT (N) 125A SOLAR LOAD CENTER (N) COMBINER BOX 5 BATTERY PROJECT NAME LU iL )E OITC j�`* A Li_ TWLZ; z Lo -0 > 'o LU ry Co EL LEG KND Lu z x 0 TTLT SOLAR LOAD CENTER _ 0 (.D - Z °* (E)MODULE S 2 IONCOR METER _LCI!z�,N'��bf'4j�;� U5 ­­01' DIA _j CO ( LU 0 LU Z fW7 0 I-ms-p MAIN SERVICE PANEL > Lu COMBINER BOX 5 z Q CD In EL 5 AC DISCONNECT < j JUNCTION BOX :E < ........... -PATJ -BATTERY 'p it. SHEET NAME �:* ......... - fuk -jv Ls .... . ... ......... ENPHASE ENERGY O8PLUS-72-M,US MICRO ROOF PLAN WITH 7 4' "'j -INVERTERS MODULES It -41C.E.NS5,"* K2 CR44X RAIL .r 0 ROOF ATTACHMENT SHEEI _iZE ANSI B PV Letterz,LCC VENT. ATTIC FAN (ROOF 11 " Firm. NO. F-244EO OBSTRUCTION) X 17" Structural Only 10/10/2024 RAFTERS SHEET NUMBER FIRE PATHWAY PV-2 UTILITY METER NO: 129 835 9541 NOTE: ACTUAL ROOF CONDITIONS AND RAFTERS (OR SEAM CONTRACTOR I ,ESIIDNO:10443720008008735 LOCATIONS MAY VARY. INSTALL PER MANUFACTURER(S) INSTALLATION GUIDELINES AND ENGINEERED SPANS FOR ATTACHMENTS ESPTEXAS PV MODULE -2214 E BELT LINE ROAD UNIT 450 DALLAS, TX 75234 SEE (2/PV-3) FOR MASTERELECTRICIAN MIKE ALV ENLARGED VIEW LICENSEA#R66EZ 7850 SIGNATURE WITH SEAL Eel- (E) COMP SHINGLE ROOF t REVISIONS REV _DESCRIPTION DATE i ON DATE INOD2024 ATTACHMENT DETAIL SCALE: NTS o� OF raj ..... ULES j tffr ........ .. r!Z,-Vuk jvNLs ING T-BOLT Z mUwok N S BOND 1440- x PROjECT NAME .--�41D CLAMP/MID CLAMP 4 %..,Zs�/OV IWI A11. %Q A /CENS LU z "PV Letters,LCC ty 'o LU A-4rM NC,, F-244E�j (3f 0 r- ry Co EL -x - LU z x o r < ------ Structural Only 10/10/2024 Z w K2 CR44X RAIL (D (D LU 0 1,- U- F- Z 0 K2 EVERFLASH XP L - FOOT > Lu z C) h SERRATED FLANGE HEX NUT 0- 5 EVERFLASH XP COMP KIT FLASHING (MASTIC, TAPE. MASTIC) -------- - (E) 2"X6" RAFTERS @ 24" O.0 < (E) COMP SHINGLE ROOF M5 x 60 LAG SCREW WITH MIN SHEET NAIME cz-k 2.5" THREAD EMBEDMENT, SEALED PENETRATION ATTACHMENT t4 DETAIL SHLEF SIZE ANSI B " 2 -ATTACHMENT DETAIL (ENLARGED VIEW) SHEEP 11X 17" NUMBER - 1 SCALE: NTS PV-3 UTILITY METER NO: 129 835 954 ESI ID NO:10443720008008735 (E)ONCOR METER — (N) ENPHASE 10 (N) AC DISCONNECT BATTERY-5P-1 P-NA 5KWH (N) SOLAR LOAD CENTER (N)ENPHASEIQ — COMBINER BOX 5 NOTE- NOTE. 3FT - CLEARANCE FOR BATTERIES FROM EXTERIOR ESS UNIT(S) NOT BE INSTALLED VENTS, DOORS, AD UNITS, POOL WITH IN T(IN ANY DIRECTION) OF ALL DOORS EQUIPMENTS, GATES, GAS(LINES) WATER AND WINDOWS, OPERABLE OPENINGS INTO SPOUTS BUILDINGS AND HVAC INLETS. (E) AC DISCONNECT (E) MAIN SERVICE PANEL (INSIDE HOUSE) — (E) LOAD CENTER -- - - - - - - - - -- - -- --------- --- -- ---- - ------- -------- - ---------- M i- ------- -------------- ----------- ----------- z__ 31-011 MIN. Hit FeA�_TE 3-ET1 F,-J� 4 L J: T (E) GAS METER sealed 1 Ood2O24 mIke@jh2dc com SOUTH-EAST WALL OUTSIDE H2DC PLLC TX CoA# F-20725 ELECTRICAL ONLY NOTANAS BUILT DRAWING SET CONTRACTOR m ESPTEXAS '214 E BELT LINE ROAD UNIT 450 DALLAS, TX 75234 MASTERELECTIRCIAN MIKE ALVAREZ LICENSE # 667850 SIGNATURE WITH SEAL REVISIONS REV DESCRIPTION DATE DATE INO9!2024 PROJECT NAME LU z Lo > Cl w ry EL LU z w I'_ z x 0 < 0 z cl) F_ w 0 Is- z 0 > LU < C) In z <0- 5 SHEET NAME ELEVATION DETAILS SHEET- SIZE ANSI B 11 " X 17" SHEET NUMBER PV-3.1 (17) HANIVIHAGLCELLS Q.PEAK DUO BLK ML-G10+ (41OW) MODULES SYSTEM SIZE:- 17 x 41OW = 6.97 kWDC UTILITY METER NO: 129 835 9541 EQUIPMENT (17) ENPHASE ENERGY IQ8PLUS-72-M-US MICRO INVERTERS ESI ID NO:10443720008008735 I SYSTEM SIZE:- 4.93 kWAC SOLAR PV (01) BRANCH OF 09 MODULES & MC DES (01) BRANCHES OF 08 MODULES CONNECTED IN PARALLEL MICRO -INVERTERS VISIBLE LOCKABLE LABELED DISCONNECT SHALL BE LOCATED WITHIN 10'OF ONCOR METER M EMPHASE 10 COMBINED 5 20 241WAC, 10. A 11) AM r240 G I� IVV 125A RATED BUS BAR, NEMA 3R SOLAR LOADS ONU UL 1741 COMPLIANT 09 MICRO INVERTERS IN BRANCH M 15A ---- - ------- - ------------ 08 M IC RO NBERTeRS IN BRANCH *2 ------- IN) 5M NA E1 4Pk . . . .. ........ ... . (17! ENPHASE ENERGY 08PLUS-OGM-US (3, #6 MICRO- NVERTERS (24OV) (C #12 O. THl �6 AI�F AVVG THOVIN G THIVN CU ONO LOCATED UNDER EACH PANEL) (1, As BARE CU IND 11 N,11'1"'�E.OTC11.INN-2 SUIT SO D 1 IN 3A'EMT CONDUIT FREE Al R BRANCH TERMINATOR aTERM FOR 10 SERIES TYP .01-0 TH __-,,. .. (1)#i 0AINGTHWINGNI) IN 3'4r EMT CONDUIT IH; I—HASE III SA PBERY.'"P.NAI (240) STORAGE S STEM 384BVA 5OP111 I OUTSIDE) L CONTROLLER 20A 20A ,f`__",,SINGLE LINE DIAGRAM SCALE: INTS COMBINER BOX AC DISCONNECT BATTERY BILL OF MATERIALS CITY DESCRIPTION 17 HANVvHA Q CELLS Q PEAK DUO BLK ML-GIC+ (4 10W) MODULES 17 ENPHASE ENERGY IQ8PLUS­72-M-US MICRO -INVERTERS I ENPHASE ENERGY !Q COMBINER BOX 5CE (24OV) (X-10-AW-240-5C) I JUNCTION BOX, 600 V, NEMA 3R, UL LISTED 60A FUSED AC DISCONNECT, OPEN VISIBLE I !LOCKABLE LABELED DISCONNECT, 240VAC 1 !ENPHASE ENERGY- QSATTERY-5P-I P-NA VISIBLE LOCKABLE LABELED ,'DISCONNECT SHALL BE LOCATED k"DTHIN 10'OF ONCOR METER SUPPO SIDE TAP .11`­ILU­ T ­rUSES v (21 . 1V111 THIN IN I"EMT CONDUIT (31 #3 AVVG THAN INI"EMTCONDLIIT Ill #5 BARE CU ONE, FREE AIR T 'TL E) MAIN BREAKER 20OAl2P,240V LE) 11AIN SERVICE PANEL, 200A RATED, 121)1240V i. T t�r CR T11 lis r fIGE ps� 5�Ali�_D fOF, ARD`CA�D ,ANO rO FE K-FT •CN -A A sealed I CocD2024 mIke&2dCrCPM I I f H2DC PLLCTXCoA# F-2,1725 ELECTRICAL ONLY NOT AN AS BUILT DRAWING SET SERVICE INFO UTILITY PROVIDER: ONCOR MAIN SERVICE VOLTAGE 240V MAIN SERVICE DISCONNECT: (E) 200A MAIN CIRCUIT BREAKER RATING: (E) 200A MAIN SERVICE LOCATION, SOUTH-EAST SERVICE FEED SOURCE UNDERGROUND CONTRACTOR m ESPTEXAS 3214 E BELT LINE ROAD UNIT 450 DALLAS, TX 75234 MASTERELECTIRCIAN MIKE ALVAREZ LICENSE # 667850 o SIGNATURE WITH SEAL REVISIONS REV DESCRIPTION DATE DATE IN09,2024 PROJECT NAME LU z Liz UU Cr EL Lu z w P z x 0 (.) Z C) Ld 0 u- Z 0 > LU z X SHEET NAIVE SINGLE LINE DIAGRAM SHEEP SIZE ANSI B 11 " X 17" SHEET NUMBER PV-4 -- --- - BILL OF MATERIALS (17) HANWHA Q.CELLS CREAK DUO BLK ML-G1O+ (41OW) MODULES SYSTEM SIZE:- 17 x 41OW = 6.97 kWDC UTILITY METER NO: 129 835 9541 EQUIPMENT CITY DESCRIPTION (ENPHASE ENERGY 108PLUS-72-M-US MICRO INVERTERS I17) 'SYSTEM w/-t::- 4.93 kWAC ESIIDNO:10443720008008735 SOLAR PV HANV*iA Q CELLS Q PEAK DUO ELK ML—GIC+ (4 1 OW) (01) BRANCH OF 09 MODULES & MODULES 17 MODULES (01) BRANCHES OF 08 MODULES CONNECTED IN PARALLEL ENPHASE ENERGY Q8PLUS-72—M—US VISIBLE LOCKABLE LABELED DISCONNECT SHALL MICRO —INVERTERS 17 MICRO —INVERTERS BE LOCATED WITHIN 1 O'OF CNCOR METER COMBINER I ENPHASE ENERGY !Q COMBINER BOX 5C, (24OV) IX-10-AW-240-5C) ,JUNCTION BOX I JUNCTION BOX, 600 V, NEMA 3R, UL LISTED 60A FUSED AC DISCONNECT, OPEN VISIBLE AC DISCONNECT I !LOCKABLE LABELED DISCONNECT, 240VAC BATTERY 1 !ENPHASE ENERGY— QEATTERY-5P—I P-NA CONTRACTOR m ESPTEXAS '214 E BELT LINE ROAD UNIT 450 DALLAS, TX 75234 MASTERELECTIRCIAN MIKE ALVAREZ LICENSE # 667850 o SIGNATURE WITH SEAL •M ENPHASE 10 COMBINED 5 0241WAC, 10. A 11) AM r 240 G I2 IVV 125A MATEO BUS BAR, NEMA 3R SOLAR LOADS ONU UL 1741 COMPLIANT .1 E.11 M, 11 1 1— , I +•" I 2-4A .11 VBB E LOCKABLE LABELED - -/DISCONNECT SHALL BE LOCATEDX- T ,�'j MICRO INVERTERS IN SRANCH,M WITHIN 10'OF ONCOR METER REVISIONS REV 11A '4 ..B..,_.ON DATE "I W111 I— DATE I9N9!A24 SUPP0 SIDE AD 201, E)MAIN 20A T 6REAKER 08 MICRO NBERTERSIN BRANCH9, 200A,2P,240V `OA H)(�V NA, rUSES E1 40A jE � MAIN SERVICE PANEL, _✓ 200A RATED, 12C,240V 111.10 G_ V I - ­ r! 43 AkIOG THI'M PROJECT NAME (_17, ENPHASE ENERGY Q3PUJS-72-M-US (3, eb (3193AWGTHIAN IN I"EMT C ONDULT MICRO -INVERTERS (24OV1 AS AND TH)UN C U G ME (2� #12 Q,CAE5LE D)(4) #10 AWG THPVN-2 A AING THDO ONO INI EMTCONDLIIT LU LOCATED UNDER EACH PANEL) (Ij BARE CU ORB N,1131�'4�'E.O'T'1),I"N,l ON D IN 1A'EMT COC NDUIT 7 FREE AIR z SUIT BARE CU GND Lo BRANCH TERMINATOR Q-TERM 2 FREE AIR 0 5; 'o LU GTHAIN FOR 10 SERIES TYP 1) #i 0AVVGTHWNGND 11 IN X4r EMT CONDUIT ry rc, EL LU z x 0 < Z w F­ IN� I—HASE III BATTERY- AP-NAI(240) T OA<�E -,_-UEA,�EC PC'r _j c) STEM c) (9 STORAGE UL ,OUTSIDE) 0 Z 0 CONTROLLER j > LU z Mii -AEL In -J m u 201 < 20A Old sealed 10oct2024 Mike@h2dccom SHEET NAME H2DC PLLC TX CoAg F-20725 ELECTRICAL ONLY Tr:: NOT AN AS BUILT DRAWING SET THREE LINE DIAGRAM SERVICE INFO UTILITY PROVIDER: ONCOR SHEEP SIZE MAIN SERVICE VOLTAGE: 240V ANSI B MAIN SERVICE DISCONNECT: (E) 200A MAIN CIRCUIT BREAKER RATING: (E� 200A 11" X 17" JHREE LINE DIAGRAM MAIN SERVICE LOCATION, SOUTH-EAST SHEET NUMBER SCALE: NTS SERVICE FEED SOURCE: UNDERGROUND PV-4.1 SOLAR MODULE SPECIFICATIONS Q.CELLS Q PEAK DUO ELK MANUFACTURER !MODEL #HANWHA ML-G10+ (41 O1)MODULES VMP 37.64 IMP 10,89 VOC 45.37 ISO 11,20 MODULE DIMENSION 74.0"L x 41.1 "W x 1.26'D (In Inch) INVERTER SPECIFICATIONS MANUFACTURER `MODEL # ENPHASE ENERGY 1Q8PLUS-72-M-US NOMINAL OUTPUT VOLTAGE 240 VAC NOMINAL OUTPUT CURRENT 1 21A AMBIENT TEMPERATURE SPECS WEATHER STATION: DALLAS LOVE FIELD RECORD LOIN TEMP AMBIENT TEMP (HIGH TEMP 2%) CONDUIT HEIGHT ROOFTOPTEMP CONDUCTOR TEMPERATURE RATE(ON ROOF) CONDUCTOR TEMPERATURE RATE(OFF ROOF) MODULE TEMPERATURE COEFFICIENT OF Voc PERCENT OF VALUES 80 70 50 AMBIENT TEMPERATURE ADJUSTMENT FOR EXPOSED CONDUIT PER CEC 310.15(B)(3)(c): (7/8"RULE) EXPECTED WIRE TEMP (°C): 37 TEMP CORRECTION PER TABLE 310.15(8)(2)(a): 0.91 # OF CURRENT CARRYING CONDUCTORS: 4 CONDUIT FILL CORRECTION PER DEC 310.15(B)(3xa): 0.80 CIRCUIT CONDUCTOR SIZE: 10 AWG CIRCUIT CONDUCTOR AMPACITY: 40A REQUIRED CIRCUIT CONDUCTOR AMPACITY PER CEC 690.8(A&B): 1.25 X # MICRO -INVERTERS (MAX. BRANCH LENGTH) X MAX OUTPUT CURRENT 1.25X09X1.21A=13.61A DEBATED AMPACITY OF CIRCUIT CONDUCTOR PER CEC TABLE 310.15(B)(2)(a ) TEMP CORR. PER CEC TABLE 310.15(BX2)(a) X so CONDUIT FILL CORR. PER CEC 310.15(B)(3)(a) X CIRCUIT CONDUCTOR AMPACITY = 3T 0.91 X 0.80 X 40 = 29.12A 0 g„ j RESULT SHOULD BE GREATER THAN (13.61A) OTHERWISE LESS THE 37' ENTRY FOR CIRCUIT CONDUCTOR SIZE AND AMPACITY q0o -0,27,,rC NUMBER OF CURRENT CARRYING CONDUCTORS IN EMT 4-6 7-5 10-20 ELECTRICAL NOTES 1, ALL EQUIPMENT TO BE LISTED BY UL OR OTHER NRTL, AND LABELED FOR ITS APPLICATION. 2. ALL CONDUCTORS SHALL BE COPPER, RATED FOR 600 V AND 90 DEGREE C WET ENVIRONMENT. 3. WIRING, CONDUIT, AND RACEWAYS MOUNTED ON ROOFTOPS SHALL BE ROUTED DIRECTLY TO, AND LOCATED AS CLOSE AS POSSIBLE TO THE NEAREST RIDGE. HIP, OR VALLEY. 4, WORKING CLEARANCES AROUND ALL NEW AND EXISTING ELECTRICAL EQUIPMENT SHALL COMPLY WITH NEC 110.26. 5. DRAWINGS INDICATE THE GENERAL ARRANGEMENT OF SYSTEMS. CONTRACTOR SHALL FURNISH ALL NECESSARY OUTLETS, SUPPORTS, FITTINGS AND ACCESSORIES TO FULFILL APPLICABLE CODES AND STANDARDS. 6, WHERE SIZES OF SOLADECK, RACEWAYS, AND CONDUITS ARE NOT SPECIFIED, THE CONTRACTOR SHALL SIZE THEM ACCORDINGLY. 7. ALL WIRE TERMINATIONS SHALL BE APPROPRIATELY LABELED AND READILY VISIBLE. 8. MODULE GROUNDING CLIPS TO BE INSTALLED BETWEEN MODULE FRAME AND MODULE SUPPORT RAIL, PER THE GROUNDING CLIP MANUFACTURER'S INSTRUCTION. 9, MODULE SUPPORT RAIL TO BE BONDED TO CONTINUOUS COPPER G.E.C. VIA WEEB LUG OR ILSCO GBL4DBT LAY -IN LUG. 10. TEMPERATURE RATINGS OF ALL CONDUCTORS, TERMINATIONS, BREAKERS, OR OTHER DEVICES ASSOCIATED WITH THE SOLAR PV SYSTEM SHALL BE RATED FOR AT LEAST 75 DEGREE C. r'~ '�,ELECTRfCAL CALCULATION J SCALE: NTS I UTILITY METER NO: 129 835 954 ,ESIID NO:10443720008008735 WIN 11111 # OF INVERTERS: 17 EXPECTED WIRE TEMP ('C): 37' TEMP CORRECTION PER TABLE 310.15(13)(2)(A): 0.88 # OF CURRENT CARRYING CONDUCTORS: 3 CONDUIT FILL PER CEC 310.15(B)(3)(A): 1.0 CIRCUIT CONDUCTOR SIZE: 3 AWG CIRCUIT CONDUCTOR AMPACITY: 100 A REQUIRED CIRCUIT CONDUCTOR AMPACITY PER GEC 690.8(B): 1.25 X (NEW SYSTEM + EXISTING SYSTEM) = 1.25 X (36.57 + 30,13) = 83.38A DERATED AMPACITY OF CIRCUIT CONDUCTORS PER CEC TABLE 310.16: TEMP CORR. PER CEC TABLE 310.15(B)(2)(A) X CONDUIT FILL CORR. PER CEC 310.15(B)(3)(A) X CIRCUIT CONDUCTOR AMPACITY W 0,88 X 1.0 X 100 =88.OA RESULT SHOULD BE GREATER THAN (83.38A) OTHERWISE LESS THE ENTRY FOR CIRCUIT CONDUCTOR SIZE AND AMPACITY AC CONDUCTOR AMPACITY CALCULATIONS:NOTES APPENIDINAPAICABLE FOR TO BE BUILT DRAVANG SETIA) TOTAL LTAGE 2P FROM COMBINER BOX TO SOLAR LOAD CENTER: DROP N,; TTO EXCEED TO INTERCONNECTION, 133% FROM IWERTER;S) TO UA LIT TRANSFORMER (B) ALL CONNECTORS 75C RATED tC) ALL CONDUCTORS COPPER, UNLESS OTHERVNSE NOTED DUE TO HIGHER CGEFFICI ENT OF EXPANSION, ALLNIMJM CONDUCTORS # OF INVERTERS: 17 REQUIRE MORE MAINTENANC&INSPECTION THAN COPPER CONDUCTORS ANNUAL RETORQUEING AS VI,ELL AS INFRARED INSPECTION, MINI RALLY, BE CAREFUL NOT TO CONNECT EXPECTED WIRE TEMP (°C): 37' ALUMINUM WTH COPPER RATED CONDUCTORS OR FITTINGS DURING CONSTRUCTION, TEMP CORRECTION PER TABLE 310.15(B)(2)(A): 0.88 TERMINALS SHOULD BE DUAL RATED MATERIAL FOR NEUTRAL AND EGC SHOULD BE THE SAME # OF CURRENT CARRYING CONDUCTORS: 3 INA GIVEN SE GMENT ID) OUTDOOR EQU;PM ENT NPOWR (El ALL CGNDUCT7RS FOR PV & ESS SYSTEMS MUST BE PROTECTED FROM ACCESS BY A FENCE OR SUITABLE COVER, OR 01-7 OF CONDUIT FILL PER DEC 310A 5(B)(3)(A): ILO REACH (F) PROPERTY LIKES, BOUNDARIES AND ALL OTHER EXTERIOR MEASUREMENTS ARE CIRCUIT CONDUCTOR SIZE: 6 AWG FOR REFERENCE ONLY, AND MUST BE VERIFIED BY A LICENSED SURVEYOR OR CIVIL ENGINEER IG } ENERGY STORAG E SYSTEM S ARE REQUIRED TO BE INSTALLED IN LOCATIONS AND CIRCUIT CONDUCTOR AMPACITY: 65 A CONTAINERS IN COMPLIANCE tMTH THEIR LISTING REQUIREMENTS (H) IF TRAVEL ACROSS A ROOF IS LIMITED TO FIRE SETBACK AREAS, FALL RESTRAINT SYSTEMS MAYBE REQUI RED 11}NO WC ALLOWED ON ROOF OR IN ATTIC (J) MC4 CONNECTORS MAY NOT BE JOINED W TH'MC4 REQUIRED CIRCUIT CONDUCTOR AMPACITY PER CEC690.8(B): COMPATIBLECONNECTORS(K)FORCOMMERCIAL SYSTEMS UNDERMODULEWRE 1.25 X ((# MICRO -INVERTERS X MAX OUTPUT CURRENT + BATTERY CURRENT) = MANAGEMENT SYSTEMS ARE REQUIRED, RACElNAY FILL MUST NOT EXCEED40% REFER TC, 1.25 X ((17 X 1.21 +16) = 4571A LOCAL REGULATIONS FOR EXCEPTIONS (L TAP CONNECTION IN PANEL. MUST NOTVIOLATE CONDITIONS OF ACCEPTABILITY FROM PANEL MANUFACTURER'S NRTL LISTING, OR FI BUD LABEL REQUIRED (M) Pt W RES MAY NOT BE LAID DIRECTLY ON RCYOF, ftU RE MANAGEMENT SUCH AS OF PER TABLE SNAKE TRAY, ETC MUST BE USED 4096 FILL MAX (N) TY VVRAPS FOR W RE t:1ANAGEMENT MUST DERATED AMPACITY CIRCUIT CONDUCTORS DEC 310.16: BE STRUCTURAL IS21) UL APPROVED, OR SUN BUNDLER OR EQUAL pO, 6RAWNGS ARE TEMP CORR. PER CEC TABLE 310.15(B)(2)(A) X DIAGRAMMATIC AND INDICATE GENERAL ARRANGEMENT OF SYSTEMS AND INORK CONDUIT CONDUIT FILL CORK. PER CEC 310A5(B)(3)(A) X ROUTING, vMHEN INDICATED, IS SHOWN DIAGRAMMATICALLY AND DOES NOT SH(SNALL CIRCUIT CONDUCTOR AMPACITY = OFFSETS, DROPS, AND RSES OF RUNS THE CONTRACTOR SHALL ALLOW IN HIS PRICE FOR ROUTING OF CONDUIT TO AVC;D OBSTRUCTIONS IF! BURIED CONDUITS UNDER AREAS SUBJECT 0.88 X 1.0 X 65 =57.2A TO VEHICLE TRAFFIC REQUIRE MIN 24" COVER (0) SOLAREDGE INVERTERS MAYBE EQUIPPED )MTH OC:PD ON DC LINES, IF NOT EXTERNAL CCPD MAYBE REQUIRED FOR STRINGS NUM PER NO I RESULT SHOULD BE GREATER THAN (45.71A) OTHERWISE LESS THE a GR MORE (R) BATTERIES MUST BE IN AN APPROVED BATTERY ENCLOSURE (SPECIFIED BY THE ENTRY FOR CIRCUIT CONDUCTOR SIZE AND AMPACITY BATTERY MANUFACTURER,, SUITABLE FOR THE UJCATION IS) NI OR PAPER INSULATED CONDUCTORS MAY NOTES USED EXTERIOR INSTEAD USE THVVN+2 OR EQUAL IN EMT CONDUIT +T)F'OR MULTIPLE BATTERIEStINVERTERS SHARING A COMMON DC BUS, CCPD PROTECTION IS REQUIREDON BOTH SIDES OF THE BUS AND AT INVERTERS DUE TO 2 WAY CURRENTS (U) THE DEVELOPER IS REQUIRED TO CONFIRM EXISTING ELECTRICAL SERVICE SIZE FROM THE UTILITY, f';_KLLE t, ye?_ IO iR AND MAY NOT RELY SOLELY ON EXISTING BREAKER SIZES N; CCNNECTiN�G TO UTILITY f ?:IC1?i'-: -__¢; E;IUIPMENT REQUIRES PRIOR UTILITY CONSENT ALL CONNECTIONS MADE FOR FLOATING (W) SOAR INSTALLATIONS, ABOVE A BODY OF WATER, MUST BE SUBMERSIBLE COMPLIANT (XI BUILDING RV SYSTEMS IMTH PO'AER LINE COMMUNI CATIONS FOR Ra'D SOLUTIONS, FOLLGL�ANG MANUFACTURERS IvNSTRJCTDONS ON CONDUCTOR AND CONDUIT SPACING IS - PARAMOUNT, OR HAZARDMAY RESULT IY)N'JTIFY ELECTRICAL ENGINEER4IMOS SEAL IS ON �....:.................. „.,,.,-,€' THIS DRAWING PRIKDR TCANYANDALLCHANGESINDESIGN Q) PROJECT RELATED t , +,i''.;SE::": zh';'h�4,•; ti.h:?'_-;:, �VJ JUBi';='7?..:. SIGNAUCOMMUN CATION CONDU:.TORS MAY ONLY BE RUN IN THE SAME CONDU:TWTH POOER CONDUCTORS IF THEIR RATING FOR THE OUTER MOST JACKET IS EQUAL TO OR GREATER THAN ._ . <,# ;HE ee;E; :,i': t:: ;s:..e :i,,:ES. TIME INSULATION REQUIRED FOR THE HIGHEST VOLTAGE POWER CONDUCTOR CIRCUIT THAT THEY ARE SHARING THE RESPECTIVE CONDUIT WTH, O'`-. TF }^, La.:;z Tr.<S,F- sealed 10oct2024 mike c�Oz,h2dc wm H2DC PLLC TX COA#, F-20725 ELECTRICAL ONLY i,LL CI ; `` E i:' NOT ANAS BUILT DRAWING SET CONTRACTOR ESPTEXAS 1214 E BELT LINE ROAD UNIT 450 DALLAS, TX 75234 MASTERELECTRICIAN MIKE ALVAREZ LICENSE # 667850 SIGNATURE WITH SEAL REVISIONS REV DESCRIPTION DATE DATE ILIOD2024 PROECT NAME LU e- Z Liz wzxry EL 0�� Z W P 0 d C Z C"} OF_- �� Z v� 0 0 SHEET NAVE ELECTRICAL CALCULATION SHEET SIZE ANSI B _ 11° X 17" SHEET NUMBER PV-5 AWARNING ELECTRICAL SHOCK HAZARD MAM - 'A TERMINALS ON LINE AND LOAD SIDES MAY BE ENERGIZED IN AC DI ScONNECT(S), PHOTOVOLTAIC 5Y STEM POINT OF THE OPEN POSITION INTERCONNECTION PER CODES. NEC 2023 VA) 54 -ABELLOCAUON INVERTEROC, AC DCSC:ONNECT,S, AF -,D -6 COMBINER FANFLAF APPLICABLBI LABEL LOCATION P R CODE .O NEC 2023 NEO 705 2071 & EMPCONDUIT RAr.FWAN S NEC 90 13,P) PERCOOE NEC R03hDA,2, �q Qill 0?- p�j A A4 nCD BAIN 3 RVICE DISCONNECT i UrILFf METER (PER CODE NEC IFO 13fB-� LABEELLOCATION ACUSCONNECT NEC 190 13,80 Ya wl UTILITN SERICCE ENTRANCENETER VERIERIDD DISCONNECT IF REOUIRED R, LOCALAHU, OR OTHER -O(ATIONS AS SECURED BY LOCAL PER CODE, -) NEC 2023 690121D)Q. NO TES AND SPECIFICATIONS SIGNS AND LABELS SHALL MEET THE REQUIREMENTS OF THE 2023ARTI-LE I 1 0 2HB, UNLESS SPECIFIC INSTRUCTION' AWARNING ARE REQUIRED BY SECTION 690, OR IF REQUESTED I, 8YT�r i LOCAL AJPJ • SI GAS ADD LABELS SHALL ADEQUATELY WARN OF HACARD S U SIN' EFFECTIVE WORDS, COLO RS AND SYMBOLS THIS DTLUIPMENT FED BY • LABELS SHALL BE PERMANENTLY AFFIXED TO THE MULTIPLE SOURCES EQUIIMEN ENTORCYRING METHOD AND SHALL NOT BE HAND TOTALRATING OF ALL OVERCURRE IBRITT • LABEL SHALL BE OF SUFFICIENT DURASLITYTO CATHSTAND DEVICESEXCLUDINGMANPOWER THE ENMRONMEKrT,NVOLVED SUPPLY SHALL NOT EXCEED • SIGN 3 AND LABELS SHALL COMPLY WITH ANSI Z535 4,2011 AMPACITY OF BUSBAR PRODUCT SAFETY SIGNS AND LABELS, UNLESS OTHERIAASE SPECIFIED • DO NOT COVER EXISTING MANUFACTURER LABELS LABEL LOCATION POINTS OF CON ECHON;BREAKER CODE NEC i0512,13131 C ELECTRIC SHOCK HAZARD A WARNING . v— T—A -- __A � 111-11l I — L-I, —1 THE DISCONNECTION OF ME GROUNDED CONDUCTORS) MAY RESULTIN OVERVOLTAGE ON THE EQUIPMENT LABEL LOCATION PER CODE NEC 690 31 1E, AUTHORIZED PERSONNEL ONLY -2 igbd2tULC T SOLAR PV SYSTEM EQUIPPED', WITY e-,APID SWUTDOWU N TURN RAPID SH UT ' .jDBEO �N POSITION TO SHUT DOWN PV SYSTEM AND REDUCE SHOCK HAZARD IN THE ARRAY. SWITCH LASELLOCARON MAIN SERVICE PANEL PER CODEOi NEC2623 PC 605 11 3 HH&690120 LABEL LOCATION: VISIBLE LOCKABLE LABELED DISCONNECT ON a. A —a T, REQ'D BY CEC 706.7(D) APPLY TO: BATTERY sealed 10oct2024 RSkeOZh2dCCOM H20C PLLC TX COA# F-20725 ELECTRICAL ONLY NOT AN AS BUILT DRAWING SET BS, LABEL LOCATION MAIN SERVICE PANEL LABEL LOCATION ALL BATTERY ASSOCIATED CONDUIT TO BE LABELED EVERY 1 OFT CATION ALTERNATE POWER SOURCE UTILITY METER NO: 129 835 954 ES1 ID NOD10443720008008735 CAUTION! MULTIPLE SOURCES OF POWER POWER TO THIS BUILDING IS ALSO SUPPLIED FROM THE FOLLOWING SOURCES WITH DISCONNECTS LOCATED AS SHOWN (N) PV ARRAY -T-7 T,'11 r,k�TC 1-�; (E) PV ARRAY SOL A 1W E AT ALL,- T 1'%" US. TI-, L�': K!, P",' 0 BATTERY OMBINERBOX EXISTINGLOAD RLOAD CENTER --J 1 CENTER AD DISCONNECT EXISTING AD ONCOR METER DISCONNECT AIN SERVICE PANEL CONTRACTOR m ESPTEXAS '214 E BELT LINE ROAD UNIT 450 DALLAS, TX 75234 NIASTERELECTRCAN MIKE ALVAREZ LICENSE # 667850 SIGNATURE WITH SEAL REVISIONS REV DESCRIPTION DATE DATE INOD2024 PROjECT NAME LU z U, 0 > (o ry ce) w r- - EL LU x 0 z z w P (-) I- x 0 (9 " u Ld 0 C, - Z 0 0 > LU < C) n z < :D SHEET NAME WARNING LABELS & PLACARD SHEEP SIZE ANSI B 11" X 17" SHEET NUMBER PV-6 ill 11111 I Wes [OMP14 Brr reaking the 20% efficiency barrier A reliable investment Enduring high performance Extreme weather rating Innovative all-weather technology The most thorough testing programme in the Industry 4, 01Y PL.-N. T.-Y BE KC-T ON The ideat wlvtioYr (ec j CONTRACTOR SERIES ESPTEXAS 1214 E BELT LINE ROAD Mechanical Specification UNIT 450 DALLAS, TX 75234 lIASTERELECTRCIAN NIIKE ALVAREZ LICENSE # 667850 SIGNATURE WITH SEAL a Electrical Characteristics POWER CLASS 385 390 395 400 405 REVISIONS REV DESCRIPTION DATE DATE INOD2024 L�j N' v M Nil Min' T�Y Oreii PERFORMANCE WARRANTY PERFORMANCE AT LOW IRRADIANCE PROJECT NAME U.1 z W EL 0 LU z X (.) z W P Z _j 01) U_ 0 r,- TEMPERATURE COEFFICIENTS Z 0 > LU z C) q (-) D_ < o Properties for System Design :j < SHEET NAIME a Oualifications and Certificates CIR CE SPEC SHEETS ,SHLEF SIZE ANSI B 11 " X 17" ocellills SHEEr NUMBER PV-7 Our iQ8 FJ ­ 'pil, ll;=J&riy`, hi IT I'll I. o'to+fll. d04-1 n"M, ph P+r— DO p.— :,AC P-111 eif 1�11WVr 7— 1— ll :,i ts— PIC4,11_ta€y •zap "oca:an ,PlUo-,topa4A,J,lw I (ASIC), I ITI, 11- h ..... v Easy to inxsa€f High productivity and reflabilfty Mm-grid-f—irig -,p ZIA— 'A—,,Cl qte, -` ;UL 1741 "A; EU 1,114%%11:1111 fui, :%f 5W CONTRACTOR m ESPTEXAS '214 E BELT LINE ROAD UNIT 450 DALLAS, TX 75234 MASTER ELECT R CI AN MIKE ALVAREZ LICENSE # 667850 SIGNATURE WITH SEAL REVISIONS REV DESCRIPTION DATE DATE INO9!2024 PROJECT NAME SHEET NAIME SPEC SHEETS SHEEP SIZE ANSI B 11 " X 17" SHEET NUMBER PV-8 ENPHASE 11111-1111. 1 711— i­­ toud.mi—i—­ lasymaicont'd "113G TI, r.gh rw A ­! g,,,, t—, 10 .�' �i­­ M""' 11'. 1­'05 EI,' e'� 1. 0AID) d.0 Iq sall." 5p 10 Load Controlle, a-af.e-1 rubC uAr M."." d"',j ­"i X-10-AW-240-5 X-I0-AMI-240-5<' s..d 971— CELLM.DrIFIAW065 5)," Easy to Vona NPIL I III J MEMA I .' 3p 1q, c 113b" $IQ, UL1741 ja & 6 USTED IQ Combiner 5/5C J w >i h t,, I,— J, L _J­ ,11 Af I. I 1A .CEVA .,.-w�-�Eir-':sa y,,r c.,-..F++:^alY" �: ,..C.,„-:, ,.- f : :kn ,r,Ax,n-1'Mr �n<rar,. rnw^an .r�,lr,��,:..,.. ,r.,n3 .r..: ,mot THM F., AT ?U. TIME". Z 5: CONTRACTOR M ESPTEXAS '214 E BELT LINE ROAD UNIT 450 DALLAS, TX 75234 MASTERELECTIRCIAN MIKE ALVAREZ LICENSE # 667850 - e SIGNATURE WITH SEAL REVISIONS REV DESCRIPTION DATE DATE '9ND2024 PROJECT NAME LU z > w cr EL Lu z x 0 Z w - (.) X c) (9 _J c) F W 0 Z 0 0 > LU C) h z 5 M SHEET NAIME SPEC SHEETS SHEEP SIZE ANSI B 11 " X 17" SHEET NUMBER PV_9 Nt— M -41, 1., 00' 14"If Accessories 1. tl, C 1 41, r 111" A A t w- E'ph-o M.1100 Connect Id, 'I U ' 'A rl It"DEM W! t`tk 47rS Sill 0"L CT-200-SOLI0 A —I AL I IF, pf-' —9-v 4, F It, 119-21"I"t"ll :11, —1-4 Q6 0"At lltk8 CONTRACTOR m ESPTEXAS '214 E BELT LINE ROAD UNIT 450 DALLAS, TX 75234 MASTERELECTIRCIAN MIKE ALVAREZ LICENSE # 667850 SIGNATURE WITH SEAL Circuit b,e.k.,. I lh REVISIONS REV DESCRIPTION DATE DATE INOD2024 CT-200-CLAMP PROJECT NAME LU z LO w Ir r) rl- EL Lu z x 0 z w P -J C) F (D W 0 u- W Z C) n 0- Q TQ Oil M 701�-C, T SHEET NAIVE tA 11"'L "WS- SPEC SHEETS ,SHLEF SIZE ANSI B 11" X 17" SHEET NUMBER PV-10 CONTRACTOR �ENPHASE cm 0 10 Battery 5P m ESPTEXAS 1214 E BELT LINE ROAD UNIT 450 DALLAS, TX 75234 MASTERELECTRCIAN MIKE ALVAREZ LICENSE # 667850 SIGNATURE WITH SEAL REVISIONS REV DESCRIPTION DATE DATE '9IOD2024 10 Battery 5P 1� PROJECT NAME LU z ry w ri LU ,r.rFi ka,2 h�'� N 0 < z x Z w t,— Z _j cl) F- W 0 u- > iT IF '�PAKVIPIF Olf"ll �11111 Ir * z C) n M S.f. < ?'E"T C11-1 3 He jlo!� St7 L: AT A; L i Z,.' F 5; SHEET NAIME plf, r'- i,' I i fE: I-,: r,'�-Pe LISTED UL9540A Certified ...... j SPEC SHEETS T ALL l-'FA-,JGE'3 1 U A F OV L C. SHLEF SIZE ANSI B 11 " X 17" SHEET NUMBER Pv- 11 zm�= tf , 7f -F, 1 - ;:al I CONTRACTOR m ESPTEXAS '214 E BELT LINE ROAD UNIT 450 DALLAS, TX 75234 MASTERELECTRCIAN MIKE ALVAREZ LICENSE # 667850 SIGNATURE WITH SEAL REVISIONS REV DESCRIPTION DATE DATE INO9!2024 PROJECT NAME SHEET NAIME SPEC SHEETS SHEEP SIZE ANSI B 11 " X 17" SHEET NUMBER PV-12 1.4 k M', 1,4-X la;', Mill 4003722 0­s.Rait 44 X I&E', Dark WX143 114 X 86 � W, Mechanical Pi-openies W, R" 4u p"d— A,F oval Ftk4oxkc sectional pfoporties mossisommm 11IMM-M units: [M.) In -TY APPf_ �OVKI Pl_AN� 7 i�', SE Ez—Y 7 CN icr _011 c A_T Al T!Nl;��, N CONTRACTOR m ESPTEXAS '214 E BELT LINE ROAD UNIT 450 DALLAS, TX 75234 MASTERELECTRICIAN MIKE ALVAREZ LICENSE # 667850 SIGNATURE WITH SEAL REVISIONS REV DESCRIPTION DATE DATE INOD2024 PROJECT NAME SHEET NAME SPEC SHEETS SHEEP SIZE ANSI B 11 " X 17" SHEET NUMBER PV-13 We support PV systems Formerly Everest Solar Systems A We support PV systems Formerly Everest Solar Systems; A q T Rj'i 6' ate; NoS!! lechnical Data rVJ 1.15 " Gol:IQ -'em"w, Lit —'LL: '13 CONTRACTOR M ESPTEXAS '214 E BELT LINE ROAD UNIT 450 DALLAS, TX 75234 MASTERELECTRCIAN MIKE ALVAREZ LICENSE # 667850 SIGNATURE WITH SEAL REVISIONS REV DESCRIPTION DATE DATE INO9!2024 PROJECT NAME LU z > w ry EL z LLJ x Z w t,- 0 —J c) 0 F (D W U- Z 0 > LU C) n z SHEET NAIME SPEC SHEETS SHEEP SIZE ANSI B 11 " X 17" SHEET NUMBER PV-14