Loading...
HomeMy WebLinkAboutCONCRETE PAVING - F241078-1440843,1440843 -10-30-2024Concrete Compression Test Report 5058 Brush Creek Rd Fort Worth, TX 76119 817-496-5600 UES Professional Solutions 44, LLC TBPELS #813 / TBPG #50341 FIELD DATA Placement Location:PAVING: NORTH AND EAST OF BUILDING 1 Project Desc:121 COMMERCE CENTER ADDITION (LOT 1) OFF GENESIS WAY AND ENCHANTED WAY Our Report #:F241078-1440843-S4 GTIS ACQUISITIONS, LLC 787 SEVENTH AVENUE, 50TH FLOOR NEW YORK, NY 10019 KYLE ROBERSONATTN: Date Placed:8/13/2024 Time Placed:N/A 5.5 2.5 84 90 Date Received:N/A Concrete Supplier:HOLCIM Submitted By:Mendoza, Andrew Plant Number:952 Delivery Ticket No.:76870703 147.5 Batch Time:8:17:00 AM Tested For: Lab No.: Cure Type: Date Tested: Age (Days): Max Load: Area: Sq. In.PSI: Cap Spec: CYLINDER COMPRESSION TEST RESULTS (ASTM C-231) Avg. Length Avg. Width Avg Depth/ Diameter Cast By:UES Cured Specification:ASTM C-31 Mix ID:5409 Break Type: Sample Location:390' S AND 120' E FROM THE NE BUILDING CORNER PM:RONNIE YEOMAN Date Issued:10/08/2024 Specified Strength:4000 Results Specification 3-5 2-6 N/A N/A N/A Air Content: Ambient Temp (F): Concrete Temp (F): Unit Weight: Slump (ASTM C-143): Weather: Wind: Clear Initial Curing Method:Protected Area, Covered with Lid Final Curing Method:Moist Room Truck Number:N/A 430 8/20/2024 7 3103012.56 2470LABC-1231 8.00 N/A 4.003 431 9/10/2024 28 5227012.56 4160LABC-1231 8.00 N/A 4.002 432 9/10/2024 28 5145012.56 4100LABC-1231 8.00 N/A 4.003 433 9/10/2024 28 5038012.56 4010LABC-1231 8.00 N/A 4.002 434 HOLD HOLD 012.56 0LABC-1231 8.00 N/A 4.00 Average 28-day Compressive Strength is compliant with project specifications CC: 4090 Respectfully Submitted By:__________________________________________________________ of UES Geotechnical Engineering * Construction Materials Testing * Environmental Engineering * Consulting 589091 Break Types: 1: Cone 2: Cone and Split 3: Columnar 4: Diagonal 5: Single Sided Fracture 6: Double Sided Fracture * = Specification out of spec Test Method: Unless noted, concrete was sampled and tested in accordance with ASTM C172, C143, C231, C173, C1064, C31, C1231 and C138. Compression strength tests per ASTM C39. Test results and reports apply only to the samples tested and/or observed, and are not indicative of the qualities of apparently identical or similar specimens. This report shall not be reproduced except in full, without the prior written approval of UES. Page 1 of 2 Concrete Compression Test Report 5058 Brush Creek Rd Fort Worth, TX 76119 817-496-5600 UES Professional Solutions 44, LLC TBPELS #813 / TBPG #50341 FIELD DATA Placement Location:PAVING: NORTH AND EAST OF BUILDING 1 Project Desc:121 COMMERCE CENTER ADDITION (LOT 1) OFF GENESIS WAY AND ENCHANTED WAY Our Report #:F241078-1440843-S5 GTIS ACQUISITIONS, LLC 787 SEVENTH AVENUE, 50TH FLOOR NEW YORK, NY 10019 KYLE ROBERSONATTN: Date Placed:8/13/2024 Time Placed:10:30 AM 5.5 2.5 88 88 Date Received:N/A Concrete Supplier:HOLCIM Submitted By:Mendoza, Andrew Plant Number:952 Delivery Ticket No.:91650693 147 Batch Time:9:39:00 AM Tested For: Lab No.: Cure Type: Date Tested: Age (Days): Max Load: Area: Sq. In.PSI: Cap Spec: CYLINDER COMPRESSION TEST RESULTS (ASTM C-231) Avg. Length Avg. Width Avg Depth/ Diameter Cast By:UES Cured Specification:ASTM C-31 Mix ID:5409 Break Type: Sample Location:360' N AND 100' E FROM THE SE BUILDING CORNER PM:RONNIE YEOMAN Date Issued:10/08/2024 Specified Strength:4000 Results Specification 3-5 2-6 N/A N/A N/A Air Content: Ambient Temp (F): Concrete Temp (F): Unit Weight: Slump (ASTM C-143): Weather: Wind: Clear Initial Curing Method:Protected Area, Covered with Lid Final Curing Method:Moist Room Truck Number:N/A 435 8/20/2024 7 4378012.56 3490LABC-1231 8.00 N/A 4.003 436 9/10/2024 28 5189012.56 4130LABC-1231 8.00 N/A 4.002 437 9/10/2024 28 5085012.56 4050LABC-1231 8.00 N/A 4.002 438 9/10/2024 28 5259012.56 4190LABC-1231 8.00 N/A 4.002 439 HOLD HOLD 012.56 0LABC-1231 8.00 N/A 4.00 Average 28-day Compressive Strength is compliant with project specifications CC: 4120 Respectfully Submitted By:__________________________________________________________ of UES Geotechnical Engineering * Construction Materials Testing * Environmental Engineering * Consulting 589092 Break Types: 1: Cone 2: Cone and Split 3: Columnar 4: Diagonal 5: Single Sided Fracture 6: Double Sided Fracture * = Specification out of spec Test Method: Unless noted, concrete was sampled and tested in accordance with ASTM C172, C143, C231, C173, C1064, C31, C1231 and C138. Compression strength tests per ASTM C39. Test results and reports apply only to the samples tested and/or observed, and are not indicative of the qualities of apparently identical or similar specimens. This report shall not be reproduced except in full, without the prior written approval of UES. Page 2 of 2