HomeMy WebLinkAboutCONCRETE PAVING - F241078-1442397,1442397,1442397,1442397,1442397 -10-3-2024Concrete Compression Test Report 5058 Brush Creek Rd Fort Worth, TX 76119 817-496-5600 UES Professional Solutions 44, LLC TBPELS #813 / TBPG #50341 FIELD DATA Placement Location:PARKING LOT, E SIDE Project Desc:121 COMMERCE CENTER ADDITION (LOT 1) OFF GENESIS WAY AND ENCHANTED WAY Our Report #:F241078-1442397-S1 GTIS ACQUISITIONS, LLC 787 SEVENTH AVENUE, 50TH FLOOR NEW YORK, NY 10019 KYLE ROBERSONATTN: Date Placed:8/16/2024 Time Placed:5:50 AM 7.00 3.5 82 95 Date Received:N/A Concrete Supplier:HOLCIM Submitted By:Alvarado, Henry Plant Number:952 Delivery Ticket No.:91650820 145 Batch Time:4:50:00 AM Tested For: Lab No.: Cure Type: Date Tested: Age (Days): Max Load: Area: Sq. In.PSI: Cap Spec: CYLINDER COMPRESSION TEST RESULTS (ASTM C-231) Avg. Length Avg. Width Avg Depth/ Diameter Cast By:UES Cured Specification:ASTM C-31 Mix ID:5409 Break Type: Sample Location:TOP LEFT QUAD. SOUTH ENTRANCE PM:RONNIE YEOMAN Date Issued:10/11/2024 Specified Strength:4000 Results Air Content: Ambient Temp (F): Concrete Temp (F): Unit Weight: Slump (ASTM C-143): Weather: Wind: Clear Initial Curing Method:Protected Area, Covered with Lid Final Curing Method:Moist Room Truck Number:5409 475 8/23/2024 7 8229028.27 2910LABC-1231 12.00 N/A 6.002 476 9/13/2024 28 11526028.27 4080LABC-1231 12.00 N/A 6.002 477 9/13/2024 28 11700028.27 4140LABC-1231 12.00 N/A 6.002 478 HOLD HOLD 028.27 0LABC-1231 12.00 N/A 6.00 Average 28-day Compressive Strength is compliant with project specifications CC: 4110 Respectfully Submitted By:__________________________________________________________ of UES Geotechnical Engineering * Construction Materials Testing * Environmental Engineering * Consulting 589964 Break Types: 1: Cone 2: Cone and Split 3: Columnar 4: Diagonal 5: Single Sided Fracture 6: Double Sided Fracture * = Specification out of spec Test Method: Unless noted, concrete was sampled and tested in accordance with ASTM C172, C143, C231, C173, C1064, C31, C1231 and C138. Compression strength tests per ASTM C39. Test results and reports apply only to the samples tested and/or observed, and are not indicative of the qualities of apparently identical or similar specimens. This report shall not be reproduced except in full, without the prior written approval of UES. Page 1 of 5 Concrete Compression Test Report 5058 Brush Creek Rd Fort Worth, TX 76119 817-496-5600 UES Professional Solutions 44, LLC TBPELS #813 / TBPG #50341 FIELD DATA Placement Location:PARKING LOT, E SIDE Project Desc:121 COMMERCE CENTER ADDITION (LOT 1) OFF GENESIS WAY AND ENCHANTED WAY Our Report #:F241078-1442397-S3 GTIS ACQUISITIONS, LLC 787 SEVENTH AVENUE, 50TH FLOOR NEW YORK, NY 10019 KYLE ROBERSONATTN: Date Placed:8/16/2024 Time Placed:7:40 AM 7.00 3.5 82 95 Date Received:N/A Concrete Supplier:HOLCIM Submitted By:Alvarado, Henry Plant Number:952 Delivery Ticket No.:91650840 145 Batch Time:6:42:00 AM Tested For: Lab No.: Cure Type: Date Tested: Age (Days): Max Load: Area: Sq. In.PSI: Cap Spec: CYLINDER COMPRESSION TEST RESULTS (ASTM C-231) Avg. Length Avg. Width Avg Depth/ Diameter Cast By:UES Cured Specification:ASTM C-31 Mix ID:5409 Break Type: Sample Location:140'N OF S END APPROACH, 20'SW OF ENCHANTMENT PM:RONNIE YEOMAN Date Issued:10/11/2024 Specified Strength:4000 Results Air Content: Ambient Temp (F): Concrete Temp (F): Unit Weight: Slump (ASTM C-143): Weather: Wind: Clear Initial Curing Method:Protected Area, Covered with Lid Final Curing Method:Moist Room Truck Number:N/A 483 8/23/2024 7 8011028.27 2830LABC-1231 12.00 N/A 6.002 484 9/13/2024 28 11409028.27 4040LABC-1231 12.00 N/A 6.003 485 9/13/2024 28 11502028.27 4070LABC-1231 12.00 N/A 6.002 486 HOLD HOLD 028.27 0LABC-1231 12.00 N/A 6.00 Average 28-day Compressive Strength is compliant with project specifications CC: 4060 Respectfully Submitted By:__________________________________________________________ of UES Geotechnical Engineering * Construction Materials Testing * Environmental Engineering * Consulting 589966 Break Types: 1: Cone 2: Cone and Split 3: Columnar 4: Diagonal 5: Single Sided Fracture 6: Double Sided Fracture * = Specification out of spec Test Method: Unless noted, concrete was sampled and tested in accordance with ASTM C172, C143, C231, C173, C1064, C31, C1231 and C138. Compression strength tests per ASTM C39. Test results and reports apply only to the samples tested and/or observed, and are not indicative of the qualities of apparently identical or similar specimens. This report shall not be reproduced except in full, without the prior written approval of UES. Page 2 of 5 Concrete Compression Test Report 5058 Brush Creek Rd Fort Worth, TX 76119 817-496-5600 UES Professional Solutions 44, LLC TBPELS #813 / TBPG #50341 FIELD DATA Placement Location:PARKING LOT, E SIDE Project Desc:121 COMMERCE CENTER ADDITION (LOT 1) OFF GENESIS WAY AND ENCHANTED WAY Our Report #:F241078-1442397-S4 GTIS ACQUISITIONS, LLC 787 SEVENTH AVENUE, 50TH FLOOR NEW YORK, NY 10019 KYLE ROBERSONATTN: Date Placed:8/16/2024 Time Placed:9:00 AM 6.50 3.5 95 95 Date Received:N/A Concrete Supplier:HOLCIM Submitted By:Alvarado, Henry Plant Number:952 Delivery Ticket No.:91650855 144 Batch Time:8:34:00 AM Tested For: Lab No.: Cure Type: Date Tested: Age (Days): Max Load: Area: Sq. In.PSI: Cap Spec: CYLINDER COMPRESSION TEST RESULTS (ASTM C-231) Avg. Length Avg. Width Avg Depth/ Diameter Cast By:UES Cured Specification:ASTM C-31 Mix ID:5409 Break Type: Sample Location:120'N, 70'W OF ENCHANTMENT PM:RONNIE YEOMAN Date Issued:10/11/2024 Specified Strength:4000 Results Air Content: Ambient Temp (F): Concrete Temp (F): Unit Weight: Slump (ASTM C-143): Weather: Wind: Clear Initial Curing Method:Protected Area, Covered with Lid Final Curing Method:Moist Room Truck Number:N/A 487 8/23/2024 7 5995028.27 2120LABC-1231 12.00 N/A 6.002 488 9/13/2024 28 11495028.27 4070LABC-1231 12.00 N/A 6.003 489 9/13/2024 28 11505028.27 4070LABC-1231 12.00 N/A 6.002 490 HOLD HOLD 028.27 0LABC-1231 12.00 N/A 6.00 Average 28-day Compressive Strength is compliant with project specifications CC: 4070 Respectfully Submitted By:__________________________________________________________ of UES Geotechnical Engineering * Construction Materials Testing * Environmental Engineering * Consulting 589967 Break Types: 1: Cone 2: Cone and Split 3: Columnar 4: Diagonal 5: Single Sided Fracture 6: Double Sided Fracture * = Specification out of spec Test Method: Unless noted, concrete was sampled and tested in accordance with ASTM C172, C143, C231, C173, C1064, C31, C1231 and C138. Compression strength tests per ASTM C39. Test results and reports apply only to the samples tested and/or observed, and are not indicative of the qualities of apparently identical or similar specimens. This report shall not be reproduced except in full, without the prior written approval of UES. Page 3 of 5 Concrete Compression Test Report 5058 Brush Creek Rd Fort Worth, TX 76119 817-496-5600 UES Professional Solutions 44, LLC TBPELS #813 / TBPG #50341 FIELD DATA Placement Location:PARKING LOT, E SIDE Project Desc:121 COMMERCE CENTER ADDITION (LOT 1) OFF GENESIS WAY AND ENCHANTED WAY Our Report #:F241078-1442397-S5 GTIS ACQUISITIONS, LLC 787 SEVENTH AVENUE, 50TH FLOOR NEW YORK, NY 10019 KYLE ROBERSONATTN: Date Placed:8/16/2024 Time Placed:10:00 AM 7.25 3.7 89 95 Date Received:N/A Concrete Supplier:HOLCIM Submitted By:Alvarado, Henry Plant Number:952 Delivery Ticket No.:91650858 145 Batch Time:8:56:00 AM Tested For: Lab No.: Cure Type: Date Tested: Age (Days): Max Load: Area: Sq. In.PSI: Cap Spec: CYLINDER COMPRESSION TEST RESULTS (ASTM C-231) Avg. Length Avg. Width Avg Depth/ Diameter Cast By:UES Cured Specification:ASTM C-31 Mix ID:5409 Break Type: Sample Location:250'N, 50'W OF ENCHANTMENT PM:RONNIE YEOMAN Date Issued:10/11/2024 Specified Strength:4000 Results Air Content: Ambient Temp (F): Concrete Temp (F): Unit Weight: Slump (ASTM C-143): Weather: Wind: Clear Initial Curing Method:Protected Area, Covered with Lid Final Curing Method:Moist Room Truck Number:N/A 491 8/23/2024 7 6038028.27 2140LABC-1231 12.00 N/A 6.002 492 9/13/2024 28 11633028.27 4110LABC-1231 12.00 N/A 6.002 493 9/13/2024 28 11529028.27 4080LABC-1231 12.00 N/A 6.003 494 HOLD HOLD 028.27 0LABC-1231 12.00 N/A 6.00 Average 28-day Compressive Strength is compliant with project specifications CC: 4100 Respectfully Submitted By:__________________________________________________________ of UES Geotechnical Engineering * Construction Materials Testing * Environmental Engineering * Consulting 589968 Break Types: 1: Cone 2: Cone and Split 3: Columnar 4: Diagonal 5: Single Sided Fracture 6: Double Sided Fracture * = Specification out of spec Test Method: Unless noted, concrete was sampled and tested in accordance with ASTM C172, C143, C231, C173, C1064, C31, C1231 and C138. Compression strength tests per ASTM C39. Test results and reports apply only to the samples tested and/or observed, and are not indicative of the qualities of apparently identical or similar specimens. This report shall not be reproduced except in full, without the prior written approval of UES. Page 4 of 5 Concrete Compression Test Report 5058 Brush Creek Rd Fort Worth, TX 76119 817-496-5600 UES Professional Solutions 44, LLC TBPELS #813 / TBPG #50341 FIELD DATA Placement Location:PARKING LOT, E SIDE Project Desc:121 COMMERCE CENTER ADDITION (LOT 1) OFF GENESIS WAY AND ENCHANTED WAY Our Report #:F241078-1442397-S6 GTIS ACQUISITIONS, LLC 787 SEVENTH AVENUE, 50TH FLOOR NEW YORK, NY 10019 KYLE ROBERSONATTN: Date Placed:8/16/2024 Time Placed:11:20 AM 7.00 3.5 94 96 Date Received:N/A Concrete Supplier:HOLCIM Submitted By:Alvarado, Henry Plant Number:952 Delivery Ticket No.:91650867 145 Batch Time:10:12:00 AM Tested For: Lab No.: Cure Type: Date Tested: Age (Days): Max Load: Area: Sq. In.PSI: Cap Spec: CYLINDER COMPRESSION TEST RESULTS (ASTM C-231) Avg. Length Avg. Width Avg Depth/ Diameter Cast By:UES Cured Specification:ASTM C-31 Mix ID:5409 Break Type: Sample Location:68'W OF ENCHANTMENT PM:RONNIE YEOMAN Date Issued:10/11/2024 Specified Strength:4000 Results Air Content: Ambient Temp (F): Concrete Temp (F): Unit Weight: Slump (ASTM C-143): Weather: Wind: Clear Initial Curing Method:Protected Area, Covered with Lid Final Curing Method:Moist Room Truck Number:N/A 495 8/23/2024 7 5837028.27 2060LABC-1231 12.00 N/A 6.002 496 9/13/2024 28 11862028.27 4200LABC-1231 12.00 N/A 6.002 497 9/13/2024 28 11655028.27 4120LABC-1231 12.00 N/A 6.003 498 HOLD HOLD 028.27 0LABC-1231 12.00 N/A 6.00 Average 28-day Compressive Strength is compliant with project specifications CC: 4160 Respectfully Submitted By:__________________________________________________________ of UES Geotechnical Engineering * Construction Materials Testing * Environmental Engineering * Consulting 589969 Break Types: 1: Cone 2: Cone and Split 3: Columnar 4: Diagonal 5: Single Sided Fracture 6: Double Sided Fracture * = Specification out of spec Test Method: Unless noted, concrete was sampled and tested in accordance with ASTM C172, C143, C231, C173, C1064, C31, C1231 and C138. Compression strength tests per ASTM C39. Test results and reports apply only to the samples tested and/or observed, and are not indicative of the qualities of apparently identical or similar specimens. This report shall not be reproduced except in full, without the prior written approval of UES. Page 5 of 5