HomeMy WebLinkAboutCONCRETE PAVING - F241078-1444436,1444436,1444436,1444436,1444436,1444436 - 9-9-2024Concrete Compression Test Report 5058 Brush Creek Rd Fort Worth, TX 76119 817-496-5600 UES Professional Solutions 44, LLC TBPELS #813 / TBPG #50341 FIELD DATA Placement Location:PAVING Project Desc:121 COMMERCE CENTER ADDITION (LOT 1) OFF GENESIS WAY AND ENCHANTED WAY Our Report #:F241078-1444436-S1 GTIS ACQUISITIONS, LLC 787 SEVENTH AVENUE, 50TH FLOOR NEW YORK, NY 10019 KYLE ROBERSONATTN: Date Placed:8/20/2024 Time Placed:5:04 AM 1.50 3.5 94 94 Date Received:N/A Concrete Supplier:HOLCIM Submitted By:James, Mark Plant Number:952 Delivery Ticket No.:91650894 147.2 Batch Time:4:34:00 AM Tested For: Lab No.: Cure Type: Date Tested: Age (Days): Max Load: Area: Sq. In.PSI: Cap Spec: CYLINDER COMPRESSION TEST RESULTS (ASTM C-231) Avg. Length Avg. Width Avg Depth/ Diameter Cast By:UES Cured Specification:ASTM C-31 Mix ID:5409 Break Type: Sample Location:200'N 50'W OF SE CORNER PM:RONNIE YEOMAN Date Issued:09/09/2024 Specified Strength:4000 Results Air Content: Ambient Temp (F): Concrete Temp (F): Unit Weight: Slump (ASTM C-143): Weather: Wind: Clear Initial Curing Method:Protected Area, Covered with Lid Final Curing Method:Moist Room Truck Number:N/A 504 8/27/2024 7 3341012.56 2660LABC-1231 8.00 N/A 4.003 505 9/17/2024 28 012.56 0LABC-1231 8.00 N/A 4.00 506 9/17/2024 28 012.56 0LABC-1231 8.00 N/A 4.00 507 9/17/2024 28 012.56 0LABC-1231 8.00 N/A 4.00 508 10/15/2024 56 012.56 0LABC-1231 8.00 N/A 4.00 CC: 0 Respectfully Submitted By:__________________________________________________________ of UES Geotechnical Engineering * Construction Materials Testing * Environmental Engineering * Consulting 590409 Break Types: 1: Cone 2: Cone and Split 3: Columnar 4: Diagonal 5: Single Sided Fracture 6: Double Sided Fracture * = Specification out of spec Test Method: Unless noted, concrete was sampled and tested in accordance with ASTM C172, C143, C231, C173, C1064, C31, C1231 and C138. Compression strength tests per ASTM C39. Test results and reports apply only to the samples tested and/or observed, and are not indicative of the qualities of apparently identical or similar specimens. This report shall not be reproduced except in full, without the prior written approval of UES. Page 1 of 6 Concrete Compression Test Report 5058 Brush Creek Rd Fort Worth, TX 76119 817-496-5600 UES Professional Solutions 44, LLC TBPELS #813 / TBPG #50341 FIELD DATA Placement Location:PAVING Project Desc:121 COMMERCE CENTER ADDITION (LOT 1) OFF GENESIS WAY AND ENCHANTED WAY Our Report #:F241078-1444436-S2 GTIS ACQUISITIONS, LLC 787 SEVENTH AVENUE, 50TH FLOOR NEW YORK, NY 10019 KYLE ROBERSONATTN: Date Placed:8/20/2024 Time Placed:6:00 AM 5.00 4.0 83 91 Date Received:N/A Concrete Supplier:HOLCIM Submitted By:James, Mark Plant Number:952 Delivery Ticket No.:91650896 147.6 Batch Time:5:17:00 AM Tested For: Lab No.: Cure Type: Date Tested: Age (Days): Max Load: Area: Sq. In.PSI: Cap Spec: CYLINDER COMPRESSION TEST RESULTS (ASTM C-231) Avg. Length Avg. Width Avg Depth/ Diameter Cast By:UES Cured Specification:ASTM C-31 Mix ID:5409 Break Type: Sample Location:150'N 20'W OF SE CORNER PM:RONNIE YEOMAN Date Issued:09/09/2024 Specified Strength:4000 Results Air Content: Ambient Temp (F): Concrete Temp (F): Unit Weight: Slump (ASTM C-143): Weather: Wind: Clear Initial Curing Method:Protected Area, Covered with Lid Final Curing Method:Moist Room Truck Number:N/A 509 8/27/2024 7 3174012.56 2530LABC-1231 8.00 N/A 4.005 510 9/17/2024 28 012.56 0LABC-1231 8.00 N/A 4.00 511 9/17/2024 28 012.56 0LABC-1231 8.00 N/A 4.00 512 9/17/2024 28 012.56 0LABC-1231 8.00 N/A 4.00 513 10/15/2024 56 012.56 0LABC-1231 8.00 N/A 4.00 CC: 0 Respectfully Submitted By:__________________________________________________________ of UES Geotechnical Engineering * Construction Materials Testing * Environmental Engineering * Consulting 590410 Break Types: 1: Cone 2: Cone and Split 3: Columnar 4: Diagonal 5: Single Sided Fracture 6: Double Sided Fracture * = Specification out of spec Test Method: Unless noted, concrete was sampled and tested in accordance with ASTM C172, C143, C231, C173, C1064, C31, C1231 and C138. Compression strength tests per ASTM C39. Test results and reports apply only to the samples tested and/or observed, and are not indicative of the qualities of apparently identical or similar specimens. This report shall not be reproduced except in full, without the prior written approval of UES. Page 2 of 6 Concrete Compression Test Report 5058 Brush Creek Rd Fort Worth, TX 76119 817-496-5600 UES Professional Solutions 44, LLC TBPELS #813 / TBPG #50341 FIELD DATA Placement Location:PAVING Project Desc:121 COMMERCE CENTER ADDITION (LOT 1) OFF GENESIS WAY AND ENCHANTED WAY Our Report #:F241078-1444436-S3 GTIS ACQUISITIONS, LLC 787 SEVENTH AVENUE, 50TH FLOOR NEW YORK, NY 10019 KYLE ROBERSONATTN: Date Placed:8/20/2024 Time Placed:7:00 AM 4.00 4.1 85 92 Date Received:N/A Concrete Supplier:HOLCIM Submitted By:James, Mark Plant Number:952 Delivery Ticket No.:76870755 147.4 Batch Time:6:17:00 AM Tested For: Lab No.: Cure Type: Date Tested: Age (Days): Max Load: Area: Sq. In.PSI: Cap Spec: CYLINDER COMPRESSION TEST RESULTS (ASTM C-231) Avg. Length Avg. Width Avg Depth/ Diameter Cast By:UES Cured Specification:ASTM C-31 Mix ID:5409 Break Type: Sample Location:75'N 35'W OF SE CORNER PM:RONNIE YEOMAN Date Issued:08/27/2024 Specified Strength:4000 Results Air Content: Ambient Temp (F): Concrete Temp (F): Unit Weight: Slump (ASTM C-143): Weather: Wind: Clear Initial Curing Method:Protected Area, Covered with Lid Final Curing Method:Moist Room Truck Number:N/A 514 8/27/2024 7 4643012.56 3700LABC-1231 8.00 N/A 4.002 515 9/17/2024 28 012.56 0LABC-1231 8.00 N/A 4.00 516 9/17/2024 28 012.56 0LABC-1231 8.00 N/A 4.00 517 9/17/2024 28 012.56 0LABC-1231 8.00 N/A 4.00 518 10/15/2024 56 012.56 0LABC-1231 8.00 N/A 4.00 CC: 0 Respectfully Submitted By:__________________________________________________________ of UES Geotechnical Engineering * Construction Materials Testing * Environmental Engineering * Consulting 590411 Break Types: 1: Cone 2: Cone and Split 3: Columnar 4: Diagonal 5: Single Sided Fracture 6: Double Sided Fracture * = Specification out of spec Test Method: Unless noted, concrete was sampled and tested in accordance with ASTM C172, C143, C231, C173, C1064, C31, C1231 and C138. Compression strength tests per ASTM C39. Test results and reports apply only to the samples tested and/or observed, and are not indicative of the qualities of apparently identical or similar specimens. This report shall not be reproduced except in full, without the prior written approval of UES. Page 3 of 6 Concrete Compression Test Report 5058 Brush Creek Rd Fort Worth, TX 76119 817-496-5600 UES Professional Solutions 44, LLC TBPELS #813 / TBPG #50341 FIELD DATA Placement Location:PAVING Project Desc:121 COMMERCE CENTER ADDITION (LOT 1) OFF GENESIS WAY AND ENCHANTED WAY Our Report #:F241078-1444436-S4 GTIS ACQUISITIONS, LLC 787 SEVENTH AVENUE, 50TH FLOOR NEW YORK, NY 10019 KYLE ROBERSONATTN: Date Placed:8/20/2024 Time Placed:8:03 AM 4.50 4.0 88 94 Date Received:N/A Concrete Supplier:HOLCIM Submitted By:James, Mark Plant Number:952 Delivery Ticket No.:91650912 147.4 Batch Time:7:15:00 AM Tested For: Lab No.: Cure Type: Date Tested: Age (Days): Max Load: Area: Sq. In.PSI: Cap Spec: CYLINDER COMPRESSION TEST RESULTS (ASTM C-231) Avg. Length Avg. Width Avg Depth/ Diameter Cast By:UES Cured Specification:ASTM C-31 Mix ID:5409 Break Type: Sample Location:30'N 10'W OF SE CORNER PM:RONNIE YEOMAN Date Issued:08/27/2024 Specified Strength:4000 Results Air Content: Ambient Temp (F): Concrete Temp (F): Unit Weight: Slump (ASTM C-143): Weather: Wind: Clear Initial Curing Method:Protected Area, Covered with Lid Final Curing Method:Moist Room Truck Number:N/A 519 8/27/2024 7 3213012.56 2560LABC-1231 8.00 N/A 4.003 520 9/17/2024 28 012.56 0LABC-1231 8.00 N/A 4.00 521 9/17/2024 28 012.56 0LABC-1231 8.00 N/A 4.00 522 9/17/2024 28 012.56 0LABC-1231 8.00 N/A 4.00 523 10/15/2024 56 012.56 0LABC-1231 8.00 N/A 4.00 CC: 0 Respectfully Submitted By:__________________________________________________________ of UES Geotechnical Engineering * Construction Materials Testing * Environmental Engineering * Consulting 590412 Break Types: 1: Cone 2: Cone and Split 3: Columnar 4: Diagonal 5: Single Sided Fracture 6: Double Sided Fracture * = Specification out of spec Test Method: Unless noted, concrete was sampled and tested in accordance with ASTM C172, C143, C231, C173, C1064, C31, C1231 and C138. Compression strength tests per ASTM C39. Test results and reports apply only to the samples tested and/or observed, and are not indicative of the qualities of apparently identical or similar specimens. This report shall not be reproduced except in full, without the prior written approval of UES. Page 4 of 6 Concrete Compression Test Report 5058 Brush Creek Rd Fort Worth, TX 76119 817-496-5600 UES Professional Solutions 44, LLC TBPELS #813 / TBPG #50341 FIELD DATA Placement Location:PAVING Project Desc:121 COMMERCE CENTER ADDITION (LOT 1) OFF GENESIS WAY AND ENCHANTED WAY Our Report #:F241078-1444436-S5 GTIS ACQUISITIONS, LLC 787 SEVENTH AVENUE, 50TH FLOOR NEW YORK, NY 10019 KYLE ROBERSONATTN: Date Placed:8/20/2024 Time Placed:8:43 AM 5.00 4.3 87 94 Date Received:N/A Concrete Supplier:HOLCIM Submitted By:James, Mark Plant Number:952 Delivery Ticket No.:91650918 147.1 Batch Time:7:53:00 AM Tested For: Lab No.: Cure Type: Date Tested: Age (Days): Max Load: Area: Sq. In.PSI: Cap Spec: CYLINDER COMPRESSION TEST RESULTS (ASTM C-231) Avg. Length Avg. Width Avg Depth/ Diameter Cast By:UES Cured Specification:ASTM C-31 Mix ID:5409 Break Type: Sample Location:APPROACH 20'S OF NE CORNER PM:RONNIE YEOMAN Date Issued:08/27/2024 Specified Strength:4000 Results Air Content: Ambient Temp (F): Concrete Temp (F): Unit Weight: Slump (ASTM C-143): Weather: Wind: Clear Initial Curing Method:Protected Area, Covered with Lid Final Curing Method:Moist Room Truck Number:N/A 524 8/27/2024 7 3103012.56 2470LABC-1231 8.00 N/A 4.003 525 9/17/2024 28 012.56 0LABC-1231 8.00 N/A 4.00 526 9/17/2024 28 012.56 0LABC-1231 8.00 N/A 4.00 527 9/17/2024 28 012.56 0LABC-1231 8.00 N/A 4.00 528 10/15/2024 56 012.56 0LABC-1231 8.00 N/A 4.00 CC: 0 Respectfully Submitted By:__________________________________________________________ of UES Geotechnical Engineering * Construction Materials Testing * Environmental Engineering * Consulting 590413 Break Types: 1: Cone 2: Cone and Split 3: Columnar 4: Diagonal 5: Single Sided Fracture 6: Double Sided Fracture * = Specification out of spec Test Method: Unless noted, concrete was sampled and tested in accordance with ASTM C172, C143, C231, C173, C1064, C31, C1231 and C138. Compression strength tests per ASTM C39. Test results and reports apply only to the samples tested and/or observed, and are not indicative of the qualities of apparently identical or similar specimens. This report shall not be reproduced except in full, without the prior written approval of UES. Page 5 of 6 Concrete Compression Test Report 5058 Brush Creek Rd Fort Worth, TX 76119 817-496-5600 UES Professional Solutions 44, LLC TBPELS #813 / TBPG #50341 FIELD DATA Placement Location:PAVING Project Desc:121 COMMERCE CENTER ADDITION (LOT 1) OFF GENESIS WAY AND ENCHANTED WAY Our Report #:F241078-1444436-S6 GTIS ACQUISITIONS, LLC 787 SEVENTH AVENUE, 50TH FLOOR NEW YORK, NY 10019 KYLE ROBERSONATTN: Date Placed:8/20/2024 Time Placed:11:00 AM 5.50 4.5 99 94 Date Received:N/A Concrete Supplier:HOLCIM Submitted By:James, Mark Plant Number:952 Delivery Ticket No.:91650927 147.4 Batch Time:10:12:00 AM Tested For: Lab No.: Cure Type: Date Tested: Age (Days): Max Load: Area: Sq. In.PSI: Cap Spec: CYLINDER COMPRESSION TEST RESULTS (ASTM C-231) Avg. Length Avg. Width Avg Depth/ Diameter Cast By:UES Cured Specification:ASTM C-31 Mix ID:5409 Break Type: Sample Location:APPROACH 20'N OF THE SE CORNER PM:RONNIE YEOMAN Date Issued:08/27/2024 Specified Strength:4000 Results Air Content: Ambient Temp (F): Concrete Temp (F): Unit Weight: Slump (ASTM C-143): Weather: Wind: Clear Initial Curing Method:Protected Area, Covered with Lid Final Curing Method:Moist Room Truck Number:N/A 529 8/27/2024 7 3754012.56 2990LABC-1231 8.00 N/A 4.003 530 9/17/2024 28 012.56 0LABC-1231 8.00 N/A 4.00 531 9/17/2024 28 012.56 0LABC-1231 8.00 N/A 4.00 532 9/17/2024 28 012.56 0LABC-1231 8.00 N/A 4.00 533 10/15/2024 56 012.56 0LABC-1231 8.00 N/A 4.00 CC: 0 Respectfully Submitted By:__________________________________________________________ of UES Geotechnical Engineering * Construction Materials Testing * Environmental Engineering * Consulting 590414 Break Types: 1: Cone 2: Cone and Split 3: Columnar 4: Diagonal 5: Single Sided Fracture 6: Double Sided Fracture * = Specification out of spec Test Method: Unless noted, concrete was sampled and tested in accordance with ASTM C172, C143, C231, C173, C1064, C31, C1231 and C138. Compression strength tests per ASTM C39. Test results and reports apply only to the samples tested and/or observed, and are not indicative of the qualities of apparently identical or similar specimens. This report shall not be reproduced except in full, without the prior written approval of UES. Page 6 of 6