Loading...
HomeMy WebLinkAboutCONCRETE PAVING - F241078-1447501,1447501 -10-30-2024Concrete Compression Test Report 5058 Brush Creek Rd Fort Worth, TX 76119 817-496-5600 UES Professional Solutions 44, LLC TBPELS #813 / TBPG #50341 FIELD DATA Placement Location:PAVING: NORTH EAST SECTION OF PARKING LOT, POUR 4 Project Desc:121 COMMERCE CENTER ADDITION (LOT 1) OFF GENESIS WAY AND ENCHANTED WAY Our Report #:F241078-1447501-S3 GTIS ACQUISITIONS, LLC 787 SEVENTH AVENUE, 50TH FLOOR NEW YORK, NY 10019 KYLE ROBERSONATTN: Date Placed:8/26/2024 Time Placed:7:20 AM 6 5.5 84 92 Date Received:N/A Concrete Supplier:HOLCIM Submitted By:Kemble, Robert Plant Number:1 Delivery Ticket No.:91490535 140.4 Batch Time:6:32:00 AM Tested For: Lab No.: Cure Type: Date Tested: Age (Days): Max Load: Area: Sq. In.PSI: Cap Spec: CYLINDER COMPRESSION TEST RESULTS (ASTM C-231) Avg. Length Avg. Width Avg Depth/ Diameter Cast By:UES Cured Specification:ASTM C-31 Mix ID:5409 Break Type: Sample Location:100'N 25'E OF SW CORNER OF POUR 4 PM:RONNIE YEOMAN Date Issued:10/21/2024 Specified Strength:4000 Results Specification 3-5 3-6 N/A 35-90 N/A Air Content: Ambient Temp (F): Concrete Temp (F): Unit Weight: Slump (ASTM C-143): Weather: Wind: Clear Initial Curing Method:Protected Area, Covered with Lid Final Curing Method:Moist Room Truck Number:N/A 594 9/2/2024 7 3900012.56 3110LABC-1231 8.00 N/A 4.002 595 9/23/2024 28 4994012.56 3980LABC-1231 8.00 N/A 4.003 596 9/23/2024 28 5113012.56 4070LABC-1231 8.00 N/A 4.002 597 9/23/2024 28 5082012.56 4050LABC-1231 8.00 N/A 4.003 598 10/21/2024 56 5418012.56 4310LABC-1231 8.00 N/A 4.002 Average 28-day Compressive Strength is compliant with project specifications CC: 4030 Respectfully Submitted By:__________________________________________________________ of UES Geotechnical Engineering * Construction Materials Testing * Environmental Engineering * Consulting 591461 Break Types: 1: Cone 2: Cone and Split 3: Columnar 4: Diagonal 5: Single Sided Fracture 6: Double Sided Fracture * = Specification out of spec Test Method: Unless noted, concrete was sampled and tested in accordance with ASTM C172, C143, C231, C173, C1064, C31, C1231 and C138. Compression strength tests per ASTM C39. Test results and reports apply only to the samples tested and/or observed, and are not indicative of the qualities of apparently identical or similar specimens. This report shall not be reproduced except in full, without the prior written approval of UES. Page 1 of 2 Concrete Compression Test Report 5058 Brush Creek Rd Fort Worth, TX 76119 817-496-5600 UES Professional Solutions 44, LLC TBPELS #813 / TBPG #50341 FIELD DATA Placement Location:PAVING: NORTH EAST SECTION OF PARKING LOT, POUR 4 Project Desc:121 COMMERCE CENTER ADDITION (LOT 1) OFF GENESIS WAY AND ENCHANTED WAY Our Report #:F241078-1447501-S4 GTIS ACQUISITIONS, LLC 787 SEVENTH AVENUE, 50TH FLOOR NEW YORK, NY 10019 KYLE ROBERSONATTN: Date Placed:8/26/2024 Time Placed:8:30 AM 5 4 84 90 Date Received:N/A Concrete Supplier:HOLCIM Submitted By:Kemble, Robert Plant Number:1 Delivery Ticket No.:91490544 141.2 Batch Time:7:18:00 AM Tested For: Lab No.: Cure Type: Date Tested: Age (Days): Max Load: Area: Sq. In.PSI: Cap Spec: CYLINDER COMPRESSION TEST RESULTS (ASTM C-231) Avg. Length Avg. Width Avg Depth/ Diameter Cast By:UES Cured Specification:ASTM C-31 Mix ID:5409 Break Type: Sample Location:140'N 30'E OF SW CORNER OF POUR 4 PM:RONNIE YEOMAN Date Issued:10/21/2024 Specified Strength:4000 Results Specification 3-5 3-6 N/A 35-90 N/A Air Content: Ambient Temp (F): Concrete Temp (F): Unit Weight: Slump (ASTM C-143): Weather: Wind: Clear Initial Curing Method:Protected Area, Covered with Lid Final Curing Method:Moist Room Truck Number:N/A 599 9/2/2024 7 3840012.56 3060LABC-1231 8.00 N/A 4.002 600 9/23/2024 28 4879012.56 3880LABC-1231 8.00 N/A 4.003 601 9/23/2024 28 4919012.56 3920LABC-1231 8.00 N/A 4.003 602 9/23/2024 28 4968012.56 3960LABC-1231 8.00 N/A 4.003 603 10/21/2024 56 5072012.56 4040LABC-1231 8.00 N/A 4.002 Average 28-day Compressive Strength is NOT compliant with project specifications CC: 3920 Respectfully Submitted By:__________________________________________________________ of UES Geotechnical Engineering * Construction Materials Testing * Environmental Engineering * Consulting 591462 Break Types: 1: Cone 2: Cone and Split 3: Columnar 4: Diagonal 5: Single Sided Fracture 6: Double Sided Fracture * = Specification out of spec Test Method: Unless noted, concrete was sampled and tested in accordance with ASTM C172, C143, C231, C173, C1064, C31, C1231 and C138. Compression strength tests per ASTM C39. Test results and reports apply only to the samples tested and/or observed, and are not indicative of the qualities of apparently identical or similar specimens. This report shall not be reproduced except in full, without the prior written approval of UES. Page 2 of 2