HomeMy WebLinkAboutCONCRETE PAVING - F241078-1454602,1454602,1454602 - 9-17-2024Concrete Compression Test Report 5058 Brush Creek Rd Fort Worth, TX 76119 817-496-5600 UES Professional Solutions 44, LLC TBPELS #813 / TBPG #50341 FIELD DATA Placement Location:PAVING: TURNING LANE Project Desc:121 COMMERCE CENTER ADDITION (LOT 1) OFF GENESIS WAY AND ENCHANTED WAY Our Report #:F241078-1454602-S1 GTIS ACQUISITIONS, LLC 787 SEVENTH AVENUE, 50TH FLOOR NEW YORK, NY 10019 KYLE ROBERSONATTN: Date Placed:9/6/2024 Time Placed:5:05 AM 5.00 3.5 70 90 Date Received:N/A Concrete Supplier:HOLCIM Submitted By:Bruner, Yusuf Plant Number:955e Delivery Ticket No.:91491063 144 Batch Time:4:14:00 AM Tested For: Lab No.: Cure Type: Date Tested: Age (Days): Max Load: Area: Sq. In.PSI: Cap Spec: CYLINDER COMPRESSION TEST RESULTS (ASTM C-231) Avg. Length Avg. Width Avg Depth/ Diameter Cast By:UES Cured Specification:ASTM C-31 Mix ID:9913HA-3 Break Type: Sample Location:15'N 28'NW OF NWC HAMPTON INN 1750 ST HWY 121 PM:RONNIE YEOMAN Date Issued:09/14/2024 Specified Strength:3000 Results Air Content: Ambient Temp (F): Concrete Temp (F): Unit Weight: Slump (ASTM C-143): Weather: Wind: Clear Initial Curing Method:Protected Area, Covered with Lid Final Curing Method:Moist Room Truck Number:N/A 659 9/13/2024 7 4757012.56 3790LABC-1231 8.00 N/A 4.003 660 10/4/2024 28 012.56 0LABC-1231 8.00 N/A 4.00 661 10/4/2024 28 012.56 0LABC-1231 8.00 N/A 4.00 662 10/4/2024 28 012.56 0LABC-1231 8.00 N/A 4.00 663 11/1/2024 56 012.56 0LABC-1231 8.00 N/A 4.00 CC: 0 Respectfully Submitted By:__________________________________________________________ of UES Geotechnical Engineering * Construction Materials Testing * Environmental Engineering * Consulting 592867 Break Types: 1: Cone 2: Cone and Split 3: Columnar 4: Diagonal 5: Single Sided Fracture 6: Double Sided Fracture * = Specification out of spec Test Method: Unless noted, concrete was sampled and tested in accordance with ASTM C172, C143, C231, C173, C1064, C31, C1231 and C138. Compression strength tests per ASTM C39. Test results and reports apply only to the samples tested and/or observed, and are not indicative of the qualities of apparently identical or similar specimens. This report shall not be reproduced except in full, without the prior written approval of UES. Page 1 of 3 Concrete Compression Test Report 5058 Brush Creek Rd Fort Worth, TX 76119 817-496-5600 UES Professional Solutions 44, LLC TBPELS #813 / TBPG #50341 FIELD DATA Placement Location:PAVING: TURNING LANE Project Desc:121 COMMERCE CENTER ADDITION (LOT 1) OFF GENESIS WAY AND ENCHANTED WAY Our Report #:F241078-1454602-S2 GTIS ACQUISITIONS, LLC 787 SEVENTH AVENUE, 50TH FLOOR NEW YORK, NY 10019 KYLE ROBERSONATTN: Date Placed:9/6/2024 Time Placed:6:20 AM 5.00 3.0 74 85 Date Received:N/A Concrete Supplier:HOLCIM Submitted By:Bruner, Yusuf Plant Number:955E Delivery Ticket No.:91491072 144 Batch Time:5:44:00 AM Tested For: Lab No.: Cure Type: Date Tested: Age (Days): Max Load: Area: Sq. In.PSI: Cap Spec: CYLINDER COMPRESSION TEST RESULTS (ASTM C-231) Avg. Length Avg. Width Avg Depth/ Diameter Cast By:UES Cured Specification:ASTM C-31 Mix ID:9913HA-3 Break Type: Sample Location:75'N 28'NW OF NWC HAMPTON INN 1750 ST HWY 121 PM:RONNIE YEOMAN Date Issued:09/14/2024 Specified Strength:3000 Results Air Content: Ambient Temp (F): Concrete Temp (F): Unit Weight: Slump (ASTM C-143): Weather: Wind: Clear Initial Curing Method:Protected Area, Covered with Lid Final Curing Method:Moist Room Truck Number:N/A 664 9/13/2024 7 6022012.56 4790LABC-1231 8.00 N/A 4.003 665 10/4/2024 28 012.56 0LABC-1231 8.00 N/A 4.00 666 10/4/2024 28 012.56 0LABC-1231 8.00 N/A 4.00 667 10/4/2024 28 012.56 0LABC-1231 8.00 N/A 4.00 668 11/1/2024 56 012.56 0LABC-1231 8.00 N/A 4.00 CC: 0 Respectfully Submitted By:__________________________________________________________ of UES Geotechnical Engineering * Construction Materials Testing * Environmental Engineering * Consulting 592868 Break Types: 1: Cone 2: Cone and Split 3: Columnar 4: Diagonal 5: Single Sided Fracture 6: Double Sided Fracture * = Specification out of spec Test Method: Unless noted, concrete was sampled and tested in accordance with ASTM C172, C143, C231, C173, C1064, C31, C1231 and C138. Compression strength tests per ASTM C39. Test results and reports apply only to the samples tested and/or observed, and are not indicative of the qualities of apparently identical or similar specimens. This report shall not be reproduced except in full, without the prior written approval of UES. Page 2 of 3 Concrete Compression Test Report 5058 Brush Creek Rd Fort Worth, TX 76119 817-496-5600 UES Professional Solutions 44, LLC TBPELS #813 / TBPG #50341 FIELD DATA Placement Location:PAVING: TURNING LANE Project Desc:121 COMMERCE CENTER ADDITION (LOT 1) OFF GENESIS WAY AND ENCHANTED WAY Our Report #:F241078-1454602-S3 GTIS ACQUISITIONS, LLC 787 SEVENTH AVENUE, 50TH FLOOR NEW YORK, NY 10019 KYLE ROBERSONATTN: Date Placed:9/6/2024 Time Placed:8:05 AM 5.00 3.0 74 90 Date Received:N/A Concrete Supplier:HOLCIM Submitted By:Bruner, Yusuf Plant Number:955E Delivery Ticket No.:91491089 144 Batch Time:7:32:00 AM Tested For: Lab No.: Cure Type: Date Tested: Age (Days): Max Load: Area: Sq. In.PSI: Cap Spec: CYLINDER COMPRESSION TEST RESULTS (ASTM C-231) Avg. Length Avg. Width Avg Depth/ Diameter Cast By:UES Cured Specification:ASTM C-31 Mix ID:9913HA-3 Break Type: Sample Location:260'N 28'NW OF NWC HAMPTON INN 1750 ST HWY 121 PM:RONNIE YEOMAN Date Issued:09/14/2024 Specified Strength:3000 Results Air Content: Ambient Temp (F): Concrete Temp (F): Unit Weight: Slump (ASTM C-143): Weather: Wind: Clear Initial Curing Method:Protected Area, Covered with Lid Final Curing Method:Moist Room Truck Number:N/A 669 9/13/2024 7 5039012.56 4010LABC-1231 8.00 N/A 4.003 670 10/4/2024 28 012.56 0LABC-1231 8.00 N/A 4.00 671 10/4/2024 28 012.56 0LABC-1231 8.00 N/A 4.00 672 10/4/2024 28 012.56 0LABC-1231 8.00 N/A 4.00 673 11/1/2024 56 012.56 0LABC-1231 8.00 N/A 4.00 CC: 0 Respectfully Submitted By:__________________________________________________________ of UES Geotechnical Engineering * Construction Materials Testing * Environmental Engineering * Consulting 592869 Break Types: 1: Cone 2: Cone and Split 3: Columnar 4: Diagonal 5: Single Sided Fracture 6: Double Sided Fracture * = Specification out of spec Test Method: Unless noted, concrete was sampled and tested in accordance with ASTM C172, C143, C231, C173, C1064, C31, C1231 and C138. Compression strength tests per ASTM C39. Test results and reports apply only to the samples tested and/or observed, and are not indicative of the qualities of apparently identical or similar specimens. This report shall not be reproduced except in full, without the prior written approval of UES. Page 3 of 3