HomeMy WebLinkAboutCONCRETE PAVING - F241078-1457995,1458040,1458041,1458041,1458041,1458041,1458041 -10-30-24Concrete Compression Test Report 5058 Brush Creek Rd Fort Worth, TX 76119 817-496-5600 UES Professional Solutions 44, LLC TBPELS #813 / TBPG #50341 FIELD DATA Placement Location:PAVING: W SIDE PARKING Project Desc:121 COMMERCE CENTER ADDITION (LOT 1) OFF GENESIS WAY AND ENCHANTED WAY Our Report #:F241078-1457995 GTIS ACQUISITIONS, LLC 787 SEVENTH AVENUE, 50TH FLOOR NEW YORK, NY 10019 KYLE ROBERSONATTN: Date Placed:9/11/2024 Time Placed:7:27 AM 7.25 4.0 70 85 Date Received:N/A Concrete Supplier:HOLCIM Submitted By:Eaton, Robert Plant Number:956 Delivery Ticket No.:76871038 144.3 Batch Time:6:10:00 AM Tested For: Lab No.: Cure Type: Date Tested: Age (Days): Max Load: Area: Sq. In.PSI: Cap Spec: CYLINDER COMPRESSION TEST RESULTS (ASTM C-231) Avg. Length Avg. Width Avg Depth/ Diameter Cast By:UES Cured Specification:ASTM C-31 Mix ID:5409 Break Type: Sample Location:440'S 120'W FROM NWC OF OFFICE BUILDING PM:RONNIE YEOMAN Date Issued:10/09/2024 Specified Strength:4000 Results Air Content: Ambient Temp (F): Concrete Temp (F): Unit Weight: Slump (ASTM C-143): Weather: Wind: Cloudy Initial Curing Method:Protected Area, Covered with Lid Final Curing Method:Moist Room Truck Number:N/A 674 9/18/2024 7 5338012.56 4250LABC-1231 8.00 N/A 4.003 675 10/9/2024 28 6061012.56 4830LABC-1231 8.00 N/A 4.002 676 10/9/2024 28 6290012.56 5010LABC-1231 8.00 N/A 4.002 677 10/9/2024 28 6307012.56 5020LABC-1231 8.00 N/A 4.002 678 HOLD HOLD 012.56 0LABC-1231 8.00 N/A 4.00 Average 28-day Compressive Strength is compliant with project specifications CC: 4950 Respectfully Submitted By:__________________________________________________________ of UES Geotechnical Engineering * Construction Materials Testing * Environmental Engineering * Consulting 593747 Break Types: 1: Cone 2: Cone and Split 3: Columnar 4: Diagonal 5: Single Sided Fracture 6: Double Sided Fracture * = Specification out of spec Test Method: Unless noted, concrete was sampled and tested in accordance with ASTM C172, C143, C231, C173, C1064, C31, C1231 and C138. Compression strength tests per ASTM C39. Test results and reports apply only to the samples tested and/or observed, and are not indicative of the qualities of apparently identical or similar specimens. This report shall not be reproduced except in full, without the prior written approval of UES. Page 1 of 7 Concrete Compression Test Report 5058 Brush Creek Rd Fort Worth, TX 76119 817-496-5600 UES Professional Solutions 44, LLC TBPELS #813 / TBPG #50341 FIELD DATA Placement Location:SIDEWALK Project Desc:121 COMMERCE CENTER ADDITION (LOT 1) OFF GENESIS WAY AND ENCHANTED WAY Our Report #:F241078-1458040 GTIS ACQUISITIONS, LLC 787 SEVENTH AVENUE, 50TH FLOOR NEW YORK, NY 10019 KYLE ROBERSONATTN: Date Placed:9/12/2024 Time Placed:5:45 AM 5.50 4.0 69 80 Date Received:N/A Concrete Supplier:HOLCIM Submitted By:Alvarado, Henry Plant Number:952 Delivery Ticket No.:91651404 145 Batch Time:4:32:00 AM Tested For: Lab No.: Cure Type: Date Tested: Age (Days): Max Load: Area: Sq. In.PSI: Cap Spec: CYLINDER COMPRESSION TEST RESULTS (ASTM C-231) Avg. Length Avg. Width Avg Depth/ Diameter Cast By:UES Cured Specification:ASTM C-31 Mix ID:5177 Break Type: Sample Location:80' SOUTHBOUND ENCHANTMENT WAY PM:RONNIE YEOMAN Date Issued:10/10/2024 Specified Strength:3000 Results Air Content: Ambient Temp (F): Concrete Temp (F): Unit Weight: Slump (ASTM C-143): Weather: Wind: Clear Initial Curing Method:Protected Area, Covered with Lid Final Curing Method:Moist Room Truck Number:N/A 679 9/19/2024 7 3749012.56 2980LABC-1231 8.00 N/A 4.002 680 10/10/2024 28 6812012.56 5420LABC-1231 8.00 N/A 4.003 681 10/10/2024 28 6693012.56 5330LABC-1231 8.00 N/A 4.003 682 10/10/2024 28 6932012.56 5520LABC-1231 8.00 N/A 4.003 683 HOLD HOLD 012.56 0LABC-1231 8.00 N/A 4.00 Average 28-day Compressive Strength is compliant with project specifications CC: 5420 Respectfully Submitted By:__________________________________________________________ of UES Geotechnical Engineering * Construction Materials Testing * Environmental Engineering * Consulting 593939 Break Types: 1: Cone 2: Cone and Split 3: Columnar 4: Diagonal 5: Single Sided Fracture 6: Double Sided Fracture * = Specification out of spec Test Method: Unless noted, concrete was sampled and tested in accordance with ASTM C172, C143, C231, C173, C1064, C31, C1231 and C138. Compression strength tests per ASTM C39. Test results and reports apply only to the samples tested and/or observed, and are not indicative of the qualities of apparently identical or similar specimens. This report shall not be reproduced except in full, without the prior written approval of UES. Page 2 of 7 Concrete Compression Test Report 5058 Brush Creek Rd Fort Worth, TX 76119 817-496-5600 UES Professional Solutions 44, LLC TBPELS #813 / TBPG #50341 FIELD DATA Placement Location:PAVING Project Desc:121 COMMERCE CENTER ADDITION (LOT 1) OFF GENESIS WAY AND ENCHANTED WAY Our Report #:F241078-1458041-S1 GTIS ACQUISITIONS, LLC 787 SEVENTH AVENUE, 50TH FLOOR NEW YORK, NY 10019 KYLE ROBERSONATTN: Date Placed:9/13/2024 Time Placed:5:29 AM 4.00 3.0 67 84 Date Received:N/A Concrete Supplier:HOLCIM Submitted By:James, Mark Plant Number:952 Delivery Ticket No.:91651432 147.2 Batch Time:N/A Tested For: Lab No.: Cure Type: Date Tested: Age (Days): Max Load: Area: Sq. In.PSI: Cap Spec: CYLINDER COMPRESSION TEST RESULTS (ASTM C-231) Avg. Length Avg. Width Avg Depth/ Diameter Cast By:UES Cured Specification:ASTM C-31 Mix ID:5409 Break Type: Sample Location:2'S 5'E OF N BOUND SERVICE RD APPROACH PM:RONNIE YEOMAN Date Issued:10/12/2024 Specified Strength:4000 Results Air Content: Ambient Temp (F): Concrete Temp (F): Unit Weight: Slump (ASTM C-143): Weather: Wind: Clear Initial Curing Method:Protected Area, Covered with Lid Final Curing Method:Moist Room Truck Number:N/A 684 9/20/2024 7 5566012.56 4430LABC-1231 8.00 N/A 4.002 685 10/11/2024 28 7231012.56 5760LABC-1231 8.00 N/A 4.003 686 10/11/2024 28 7222012.56 5750LABC-1231 8.00 N/A 4.003 687 10/11/2024 28 7241012.56 5770LABC-1231 8.00 N/A 4.003 688 HOLD HOLD 012.56 0LABC-1231 8.00 N/A 4.00 Average 28-day Compressive Strength is compliant with project specifications CC: 5760 Respectfully Submitted By:__________________________________________________________ of UES Geotechnical Engineering * Construction Materials Testing * Environmental Engineering * Consulting 594169 Break Types: 1: Cone 2: Cone and Split 3: Columnar 4: Diagonal 5: Single Sided Fracture 6: Double Sided Fracture * = Specification out of spec Test Method: Unless noted, concrete was sampled and tested in accordance with ASTM C172, C143, C231, C173, C1064, C31, C1231 and C138. Compression strength tests per ASTM C39. Test results and reports apply only to the samples tested and/or observed, and are not indicative of the qualities of apparently identical or similar specimens. This report shall not be reproduced except in full, without the prior written approval of UES. Page 3 of 7 Concrete Compression Test Report 5058 Brush Creek Rd Fort Worth, TX 76119 817-496-5600 UES Professional Solutions 44, LLC TBPELS #813 / TBPG #50341 FIELD DATA Placement Location:PAVING Project Desc:121 COMMERCE CENTER ADDITION (LOT 1) OFF GENESIS WAY AND ENCHANTED WAY Our Report #:F241078-1458041-S2 GTIS ACQUISITIONS, LLC 787 SEVENTH AVENUE, 50TH FLOOR NEW YORK, NY 10019 KYLE ROBERSONATTN: Date Placed:9/13/2024 Time Placed:6:00 AM 4.00 3.2 67 83 Date Received:N/A Concrete Supplier:HOLCIM Submitted By:James, Mark Plant Number:952 Delivery Ticket No.:91651079 148.8 Batch Time:5:12:00 AM Tested For: Lab No.: Cure Type: Date Tested: Age (Days): Max Load: Area: Sq. In.PSI: Cap Spec: CYLINDER COMPRESSION TEST RESULTS (ASTM C-231) Avg. Length Avg. Width Avg Depth/ Diameter Cast By:UES Cured Specification:ASTM C-31 Mix ID:5409 Break Type: Sample Location:10'S 55'E OF N BOUND SERVICE RD APPROACH PM:RONNIE YEOMAN Date Issued:10/12/2024 Specified Strength:4000 Results Air Content: Ambient Temp (F): Concrete Temp (F): Unit Weight: Slump (ASTM C-143): Weather: Wind: Clear Initial Curing Method:Protected Area, Covered with Lid Final Curing Method:Moist Room Truck Number:N/A 689 9/20/2024 7 5330012.56 4240LABC-1231 8.00 N/A 4.002 690 10/11/2024 28 6486012.56 5160LABC-1231 8.00 N/A 4.003 691 10/11/2024 28 6236012.56 4960LABC-1231 8.00 N/A 4.002 692 10/11/2024 28 6362012.56 5070LABC-1231 8.00 N/A 4.003 693 HOLD HOLD 012.56 0LABC-1231 8.00 N/A 4.00 Average 28-day Compressive Strength is compliant with project specifications CC: 5060 Respectfully Submitted By:__________________________________________________________ of UES Geotechnical Engineering * Construction Materials Testing * Environmental Engineering * Consulting 594170 Break Types: 1: Cone 2: Cone and Split 3: Columnar 4: Diagonal 5: Single Sided Fracture 6: Double Sided Fracture * = Specification out of spec Test Method: Unless noted, concrete was sampled and tested in accordance with ASTM C172, C143, C231, C173, C1064, C31, C1231 and C138. Compression strength tests per ASTM C39. Test results and reports apply only to the samples tested and/or observed, and are not indicative of the qualities of apparently identical or similar specimens. This report shall not be reproduced except in full, without the prior written approval of UES. Page 4 of 7 Concrete Compression Test Report 5058 Brush Creek Rd Fort Worth, TX 76119 817-496-5600 UES Professional Solutions 44, LLC TBPELS #813 / TBPG #50341 FIELD DATA Placement Location:PAVING Project Desc:121 COMMERCE CENTER ADDITION (LOT 1) OFF GENESIS WAY AND ENCHANTED WAY Our Report #:F241078-1458041-S3 GTIS ACQUISITIONS, LLC 787 SEVENTH AVENUE, 50TH FLOOR NEW YORK, NY 10019 KYLE ROBERSONATTN: Date Placed:9/13/2024 Time Placed:8:15 AM 5.00 6.3 70 82 Date Received:N/A Concrete Supplier:HOLCIM Submitted By:James, Mark Plant Number:952 Delivery Ticket No.:91651441 147.6 Batch Time:6:47:00 AM Tested For: Lab No.: Cure Type: Date Tested: Age (Days): Max Load: Area: Sq. In.PSI: Cap Spec: CYLINDER COMPRESSION TEST RESULTS (ASTM C-231) Avg. Length Avg. Width Avg Depth/ Diameter Cast By:UES Cured Specification:ASTM C-31 Mix ID:5409 Break Type: Sample Location:40'S 25'E OF N BOUND SERVICE RD APPROACH PM:RONNIE YEOMAN Date Issued:10/12/2024 Specified Strength:4000 Results Air Content: Ambient Temp (F): Concrete Temp (F): Unit Weight: Slump (ASTM C-143): Weather: Wind: Clear Initial Curing Method:Protected Area, Covered with Lid Final Curing Method:Moist Room Truck Number:N/A 694 9/20/2024 7 5252012.56 4180LABC-1231 8.00 N/A 4.002 695 10/11/2024 28 6112012.56 4870LABC-1231 8.00 N/A 4.002 696 10/11/2024 28 6097012.56 4850LABC-1231 8.00 N/A 4.003 697 10/11/2024 28 6084012.56 4840LABC-1231 8.00 N/A 4.003 698 HOLD HOLD 012.56 0LABC-1231 8.00 N/A 4.00 Average 28-day Compressive Strength is compliant with project specifications CC: 4850 Respectfully Submitted By:__________________________________________________________ of UES Geotechnical Engineering * Construction Materials Testing * Environmental Engineering * Consulting 594171 Break Types: 1: Cone 2: Cone and Split 3: Columnar 4: Diagonal 5: Single Sided Fracture 6: Double Sided Fracture * = Specification out of spec Test Method: Unless noted, concrete was sampled and tested in accordance with ASTM C172, C143, C231, C173, C1064, C31, C1231 and C138. Compression strength tests per ASTM C39. Test results and reports apply only to the samples tested and/or observed, and are not indicative of the qualities of apparently identical or similar specimens. This report shall not be reproduced except in full, without the prior written approval of UES. Page 5 of 7 Concrete Compression Test Report 5058 Brush Creek Rd Fort Worth, TX 76119 817-496-5600 UES Professional Solutions 44, LLC TBPELS #813 / TBPG #50341 FIELD DATA Placement Location:PAVING Project Desc:121 COMMERCE CENTER ADDITION (LOT 1) OFF GENESIS WAY AND ENCHANTED WAY Our Report #:F241078-1458041-S4 GTIS ACQUISITIONS, LLC 787 SEVENTH AVENUE, 50TH FLOOR NEW YORK, NY 10019 KYLE ROBERSONATTN: Date Placed:9/13/2024 Time Placed:9:37 AM 7.50 7.0 75 86 Date Received:N/A Concrete Supplier:HOLCIM Submitted By:James, Mark Plant Number:952 Delivery Ticket No.:91651089 148 Batch Time:8:25:00 AM Tested For: Lab No.: Cure Type: Date Tested: Age (Days): Max Load: Area: Sq. In.PSI: Cap Spec: CYLINDER COMPRESSION TEST RESULTS (ASTM C-231) Avg. Length Avg. Width Avg Depth/ Diameter Cast By:UES Cured Specification:ASTM C-31 Mix ID:5409 Break Type: Sample Location:70'S 35'E OF N BOUND SERVICE RD APPROACH PM:RONNIE YEOMAN Date Issued:10/12/2024 Specified Strength:4000 Results Air Content: Ambient Temp (F): Concrete Temp (F): Unit Weight: Slump (ASTM C-143): Weather: Wind: Clear Initial Curing Method:Protected Area, Covered with Lid Final Curing Method:Moist Room Truck Number:N/A 699 9/20/2024 7 4382012.56 3490LABC-1231 8.00 N/A 4.003 700 10/11/2024 28 5609012.56 4470LABC-1231 8.00 N/A 4.003 701 10/11/2024 28 5384012.56 4290LABC-1231 8.00 N/A 4.002 702 10/11/2024 28 5481012.56 4360LABC-1231 8.00 N/A 4.002 703 HOLD HOLD 012.56 0LABC-1231 8.00 N/A 4.00 Average 28-day Compressive Strength is compliant with project specifications CC: 4370 Respectfully Submitted By:__________________________________________________________ of UES Geotechnical Engineering * Construction Materials Testing * Environmental Engineering * Consulting 594172 Break Types: 1: Cone 2: Cone and Split 3: Columnar 4: Diagonal 5: Single Sided Fracture 6: Double Sided Fracture * = Specification out of spec Test Method: Unless noted, concrete was sampled and tested in accordance with ASTM C172, C143, C231, C173, C1064, C31, C1231 and C138. Compression strength tests per ASTM C39. Test results and reports apply only to the samples tested and/or observed, and are not indicative of the qualities of apparently identical or similar specimens. This report shall not be reproduced except in full, without the prior written approval of UES. Page 6 of 7 Concrete Compression Test Report 5058 Brush Creek Rd Fort Worth, TX 76119 817-496-5600 UES Professional Solutions 44, LLC TBPELS #813 / TBPG #50341 FIELD DATA Placement Location:PAVING Project Desc:121 COMMERCE CENTER ADDITION (LOT 1) OFF GENESIS WAY AND ENCHANTED WAY Our Report #:F241078-1458041-S5 GTIS ACQUISITIONS, LLC 787 SEVENTH AVENUE, 50TH FLOOR NEW YORK, NY 10019 KYLE ROBERSONATTN: Date Placed:9/13/2024 Time Placed:10:34 AM 6.50 4.3 80 88 Date Received:N/A Concrete Supplier:HOLCIM Submitted By:James, Mark Plant Number:952 Delivery Ticket No.:91651454 148.2 Batch Time:9:36:00 AM Tested For: Lab No.: Cure Type: Date Tested: Age (Days): Max Load: Area: Sq. In.PSI: Cap Spec: CYLINDER COMPRESSION TEST RESULTS (ASTM C-231) Avg. Length Avg. Width Avg Depth/ Diameter Cast By:UES Cured Specification:ASTM C-31 Mix ID:5409 Break Type: Sample Location:100'S 30'E OF N BOUND SERVICE RD APPROACH PM:RONNIE YEOMAN Date Issued:10/30/2024 Specified Strength:4000 Results Air Content: Ambient Temp (F): Concrete Temp (F): Unit Weight: Slump (ASTM C-143): Weather: Wind: Clear Initial Curing Method:Protected Area, Covered with Lid Final Curing Method:Moist Room Truck Number:N/A 704 9/20/2024 7 3925012.56 3120LABC-1231 8.00 N/A 4.001 705 10/11/2024 28 5718012.56 4550LABC-1231 8.00 N/A 4.002 706 10/11/2024 28 5522012.56 4400LABC-1231 8.00 N/A 4.002 707 10/11/2024 28 5659012.56 4510LABC-1231 8.00 N/A 4.002 708 11/8/2024 56 012.56 0LABC-1231 8.00 N/A 4.00 Average 28-day Compressive Strength is compliant with project specifications CC: 4490 Respectfully Submitted By:__________________________________________________________ of UES Geotechnical Engineering * Construction Materials Testing * Environmental Engineering * Consulting 594173 Break Types: 1: Cone 2: Cone and Split 3: Columnar 4: Diagonal 5: Single Sided Fracture 6: Double Sided Fracture * = Specification out of spec Test Method: Unless noted, concrete was sampled and tested in accordance with ASTM C172, C143, C231, C173, C1064, C31, C1231 and C138. Compression strength tests per ASTM C39. Test results and reports apply only to the samples tested and/or observed, and are not indicative of the qualities of apparently identical or similar specimens. This report shall not be reproduced except in full, without the prior written approval of UES. Page 7 of 7