Loading...
HomeMy WebLinkAboutCONCRETE PAVING - F241078-14428081442808144443614444361444436 -10-31-2024Concrete Compression Test Report 5058 Brush Creek Rd Fort Worth, TX 76119 817-496-5600 UES Professional Solutions 44, LLC TBPELS #813 / TBPG #50341 FIELD DATA Placement Location:PAVING Project Desc:121 COMMERCE CENTER ADDITION (LOT 1) OFF GENESIS WAY AND ENCHANTED WAY Our Report #:F241078-1444436-S2 GTIS ACQUISITIONS, LLC 787 SEVENTH AVENUE, 50TH FLOOR NEW YORK, NY 10019 KYLE ROBERSONATTN: Date Placed:8/20/2024 Time Placed:6:00 AM 5.00 4.0 83 91 Date Received:N/A Concrete Supplier:HOLCIM Submitted By:James, Mark Plant Number:952 Delivery Ticket No.:91650896 147.6 Batch Time:5:17:00 AM Tested For: Lab No.: Cure Type: Date Tested: Age (Days): Max Load: Area: Sq. In.PSI: Cap Spec: CYLINDER COMPRESSION TEST RESULTS (ASTM C-231) Avg. Length Avg. Width Avg Depth/ Diameter Cast By:UES Cured Specification:ASTM C-31 Mix ID:5409 Break Type: Sample Location:150'N 20'W OF SE CORNER PM:RONNIE YEOMAN Date Issued:10/15/2024 Specified Strength:4000 Results Air Content: Ambient Temp (F): Concrete Temp (F): Unit Weight: Slump (ASTM C-143): Weather: Wind: Clear Initial Curing Method:Protected Area, Covered with Lid Final Curing Method:Moist Room Truck Number:N/A 509 8/27/2024 7 3174012.56 2530LABC-1231 8.00 N/A 4.005 510 9/17/2024 28 5257012.56 4190LABC-1231 8.00 N/A 4.002 511 9/17/2024 28 5393012.56 4290LABC-1231 8.00 N/A 4.002 512 9/17/2024 28 5297012.56 4220LABC-1231 8.00 N/A 4.002 513 HOLD HOLD 012.56 0LABC-1231 8.00 N/A 4.00 Average 28-day Compressive Strength is compliant with project specifications CC: 4230 Respectfully Submitted By:__________________________________________________________ of UES Geotechnical Engineering * Construction Materials Testing * Environmental Engineering * Consulting 590410 Break Types: 1: Cone 2: Cone and Split 3: Columnar 4: Diagonal 5: Single Sided Fracture 6: Double Sided Fracture * = Specification out of spec Test Method: Unless noted, concrete was sampled and tested in accordance with ASTM C172, C143, C231, C173, C1064, C31, C1231 and C138. Compression strength tests per ASTM C39. Test results and reports apply only to the samples tested and/or observed, and are not indicative of the qualities of apparently identical or similar specimens. This report shall not be reproduced except in full, without the prior written approval of UES. Page 1 of 5 Concrete Compression Test Report 5058 Brush Creek Rd Fort Worth, TX 76119 817-496-5600 UES Professional Solutions 44, LLC TBPELS #813 / TBPG #50341 FIELD DATA Placement Location:PAVING Project Desc:121 COMMERCE CENTER ADDITION (LOT 1) OFF GENESIS WAY AND ENCHANTED WAY Our Report #:F241078-1444436-S4 GTIS ACQUISITIONS, LLC 787 SEVENTH AVENUE, 50TH FLOOR NEW YORK, NY 10019 KYLE ROBERSONATTN: Date Placed:8/20/2024 Time Placed:8:03 AM 4.50 4.0 88 94 Date Received:N/A Concrete Supplier:HOLCIM Submitted By:James, Mark Plant Number:952 Delivery Ticket No.:91650912 147.4 Batch Time:7:15:00 AM Tested For: Lab No.: Cure Type: Date Tested: Age (Days): Max Load: Area: Sq. In.PSI: Cap Spec: CYLINDER COMPRESSION TEST RESULTS (ASTM C-231) Avg. Length Avg. Width Avg Depth/ Diameter Cast By:UES Cured Specification:ASTM C-31 Mix ID:5409 Break Type: Sample Location:30'N 10'W OF SE CORNER PM:RONNIE YEOMAN Date Issued:10/15/2024 Specified Strength:4000 Results Air Content: Ambient Temp (F): Concrete Temp (F): Unit Weight: Slump (ASTM C-143): Weather: Wind: Clear Initial Curing Method:Protected Area, Covered with Lid Final Curing Method:Moist Room Truck Number:N/A 519 8/27/2024 7 3213012.56 2560LABC-1231 8.00 N/A 4.003 520 9/17/2024 28 5302012.56 4220LABC-1231 8.00 N/A 4.003 521 9/17/2024 28 5238012.56 4170LABC-1231 8.00 N/A 4.003 522 9/17/2024 28 5155012.56 4100LABC-1231 8.00 N/A 4.003 523 HOLD HOLD 012.56 0LABC-1231 8.00 N/A 4.00 Average 28-day Compressive Strength is compliant with project specifications CC: 4160 Respectfully Submitted By:__________________________________________________________ of UES Geotechnical Engineering * Construction Materials Testing * Environmental Engineering * Consulting 590412 Break Types: 1: Cone 2: Cone and Split 3: Columnar 4: Diagonal 5: Single Sided Fracture 6: Double Sided Fracture * = Specification out of spec Test Method: Unless noted, concrete was sampled and tested in accordance with ASTM C172, C143, C231, C173, C1064, C31, C1231 and C138. Compression strength tests per ASTM C39. Test results and reports apply only to the samples tested and/or observed, and are not indicative of the qualities of apparently identical or similar specimens. This report shall not be reproduced except in full, without the prior written approval of UES. Page 2 of 5 Concrete Compression Test Report 5058 Brush Creek Rd Fort Worth, TX 76119 817-496-5600 UES Professional Solutions 44, LLC TBPELS #813 / TBPG #50341 FIELD DATA Placement Location:PAVING Project Desc:121 COMMERCE CENTER ADDITION (LOT 1) OFF GENESIS WAY AND ENCHANTED WAY Our Report #:F241078-1444436-S5 GTIS ACQUISITIONS, LLC 787 SEVENTH AVENUE, 50TH FLOOR NEW YORK, NY 10019 KYLE ROBERSONATTN: Date Placed:8/20/2024 Time Placed:8:43 AM 5.00 4.3 87 94 Date Received:N/A Concrete Supplier:HOLCIM Submitted By:James, Mark Plant Number:952 Delivery Ticket No.:91650918 147.1 Batch Time:7:53:00 AM Tested For: Lab No.: Cure Type: Date Tested: Age (Days): Max Load: Area: Sq. In.PSI: Cap Spec: CYLINDER COMPRESSION TEST RESULTS (ASTM C-231) Avg. Length Avg. Width Avg Depth/ Diameter Cast By:UES Cured Specification:ASTM C-31 Mix ID:5409 Break Type: Sample Location:APPROACH 20'S OF NE CORNER PM:RONNIE YEOMAN Date Issued:10/15/2024 Specified Strength:4000 Results Air Content: Ambient Temp (F): Concrete Temp (F): Unit Weight: Slump (ASTM C-143): Weather: Wind: Clear Initial Curing Method:Protected Area, Covered with Lid Final Curing Method:Moist Room Truck Number:N/A 524 8/27/2024 7 3103012.56 2470LABC-1231 8.00 N/A 4.003 525 9/17/2024 28 5080012.56 4040LABC-1231 8.00 N/A 4.002 526 9/17/2024 28 5107012.56 4070LABC-1231 8.00 N/A 4.002 527 9/17/2024 28 5269012.56 4200LABC-1231 8.00 N/A 4.003 528 HOLD HOLD 012.56 0LABC-1231 8.00 N/A 4.00 Average 28-day Compressive Strength is compliant with project specifications CC: 4100 Respectfully Submitted By:__________________________________________________________ of UES Geotechnical Engineering * Construction Materials Testing * Environmental Engineering * Consulting 590413 Break Types: 1: Cone 2: Cone and Split 3: Columnar 4: Diagonal 5: Single Sided Fracture 6: Double Sided Fracture * = Specification out of spec Test Method: Unless noted, concrete was sampled and tested in accordance with ASTM C172, C143, C231, C173, C1064, C31, C1231 and C138. Compression strength tests per ASTM C39. Test results and reports apply only to the samples tested and/or observed, and are not indicative of the qualities of apparently identical or similar specimens. This report shall not be reproduced except in full, without the prior written approval of UES. Page 3 of 5