Loading...
HomeMy WebLinkAboutPIERS - F241078-1434572 - 8-9-2024Instrument Used: COMBINED FLATNESS F-NUMBER (FF) Specified Limits: *BASED UPON THE NUMBER OF SAMPLES TAKEN, THERE IS A 90% CERTAINTY THAT THE ACTUAL F-NUMBERS OF THE SURFACE SURVEYED WILL FALL WITHIN THE RANGES WHICH FOLLOW THE RESPECTIVE ESTIMATED FLATNESS AND LEVELNESS F-NUMBERS. 52.07 45.85 UES / Riner Engineering Combined Overall: COMBINED LEVELNESS F-NUMBER (FL) FL - SPECIFIED OVERALL VALUE:35 50 Value Results: "DIPSTICK 2272", MANUFACTURED BY FACE TECHNOLOGIES Respectfully Submitted, 08/02/2024 approval. Test results and reports apply only to the samples tested and/or observed, and are not indicative of the qualities of apparently identical or similar specimens. Technician time is from portal to portal. MF-010(8/2/2016) This report is in general compliance with one or more of the following technical standards: C31-15, C39-16, C138-16, C143-15, C172-14, C173-16, C231-14, C293-15, C617-15, C1064-12, C1231-15 Ronnie Yeoman Project Manager Our test results and reports are for the exclusive use of the Client (and designated recipients) and shall not be reproduced and/or distributed except with express approval of UES. The use of our name and test results must receive our written 35 FL - MINIMUM OVERALL VALUE: Approximate Area: ASTM Standard: 29,700 ASTM E 1155 Work Order Number: Project Number: Technician: Page Number: Sampling Method: FF - MINIMUM OVERALL VALUE: 25 Remarks: 121 Commerce Center Addition (Lot 1) Service Date:Client: Off Genesis Way and Enchanted Way Clear 8/9/2024 F241078 1434572 1 POINT ELEVATIONS WERE MEASURED AT REGULAR 12 INCH INTERVALS ALONG STRAIGHT LINES UP TO 106 FEET IN LENGTH. THE ELEVATION DIFFERENCES BETWEEN ALL ADJACENT READING POINTS, THE ARITHMETIC DIFFERENCES BETWEEN ALL ADJACENT 12 INCH ELEVATION DIFFERENCES, AND THE ELEVATION DIFFERENCES BETWEEN ALL POINTS SEPARATED 10 FEET WERE THEN CALCULATED. ESTIMATES OF THE FLOOR'S FLATNESS AND LEVELNESS F-NUMBERS (FF AND FL) WERE OBTAINED THROUGH A STATISTICAL ANALYSIS OF THESE CALCULATED PROFILE VALUES. SEE ATTACHED REPORTS FOR INDIVIDUAL MEASUREMENT LINE RESULTS. 8/2/2024Date of Placement: GTIS Acquisitions, LLC 787 Seventh Avenue, 50th Floor New York, NY 10019 Environmental Consulting & Permit Support | Geotechnical Engineering | Materials Testing & Special Inspections | Geophysical Technologies Project: Report Date: Weather: 5058 Brush Creek Rd Fort Worth, TX 76119 www.TeamUES.com TBPELS Firm No. 813 Report of Floor Flatness Observation FLOOR SURFACE ANALYSIS Location Surveyed:Slab at C-E/8-12 Martinez, Austin FF - SPECIFIED OVERALL VALUE: of1Grapevine, Texas