HomeMy WebLinkAboutMOISTURE DENSITY - F241078-142166397 98 19.8 95120.4 120.8 121.6 104.4 16.5 101.6 18.9 100.516 99 6 Storm Drain Line A- Station 1+40 FG-2.5 1 6 120.5 120.1 102.0 103.1 120.7 119.6 101.9 17.4 97 99 101.1 19.4 96 16.2 4 Storm Drain Line A- Station 1+45 FG-3.0 10 Storm Drain Line A- Station 1+40 FG-1.5 1 6 6 7 Storm Drain Line A- Station 3+50 FG-2.0 1 6 5 Storm Drain Line A- Station 4+00 FG-2.5 1 6 119.6 101.8 9 Storm Drain Line A- Station 4+00 FG-1.5 1 6 8 Storm Drain Line A- Station 1+45 FG-2.0 1 120.2 100.3 20.0 3 Storm Drain Line A- Station 3+50 FG-3.0 1 6 2 Storm Drain Line A- Station 1+40 FG-3.5 1 6 121.4 104.5 1 Storm Drain Line A- Station 4+00 FG-3.5 1 6 11 Storm Drain Line A- Station 3+50 FG-1.0 1 6 12 Storm Drain Line A- Station 1+45 FG-1.0 1 6 Clear 101.3 19.0 96 95 17.5 96 96 97 17.7 16.9 1421663 Project:121 Commerce Center Addition (Lot 1)Project Number:F241078 Client:GTIS Acquisitions, LLC Service Date:7/10/2024 5058 Brush Creek Rd Fort Worth, TX 76119 www.TeamUES.com TBPELS Firm No. 813 In-Place Nuclear Density Test Report Work Order Number: 787 Seventh Avenue, 50th Floor Report Date:7/26/2024 New York, NY 10019 Weather: Off Genesis Way and Enchanted Way Technician:Reyes, Ruben Grapevine, Texas Page Number:1 of 1 Material Information Laboratory Data 39Dark Brown and Brown Sandy Clay 105.3 Project Specifications Mat. No. Optimum Moisture (%) Max Dry Weight (pcf) Proctor Report No. Moisture Min. (%) Max. Compaction Min. (%) Max.Material Description/Classification PI -2 2 953 General Location Area:Utilities/Paving Area 100118.0 101.5 18.6 Field Test Data Test No.Test Location Lift/ Depth Mat. No. Probe Depth (in.) Wet Density (pcf) Dry Density (pcf) Percent Moisture (%) Percent Compaction (%) Gauge Information Non-compliant results are indicated by an asterisk(*) if applicable. Serial No:4457 Manufacturer:Instrotek Model:(D): 2242 (M):727Standard Count: 120.5 120.4 Remarks: Respectfully Submitted, Ronnie Yeoman approval. Test results and reports apply only to the samples tested and/or observed, and are not indicative of the qualities of apparently identical or similar specimens. Technician time is from portal to portal. MF-010(8/2/2016) Environmental Consulting & Permit Support | Geotechnical Engineering | Materials Testing & Special Inspections | Geophysical Technologies This report is in general compliance with one or more of the following technical standards: D6938-15 Our test results and reports are for the exclusive use of the Client (and designated recipients) and shall not be reproduced and/or distributed except with express approval of UES. The use of our name and test results must receive our written Project Manager UES / Riner Engineering