HomeMy WebLinkAboutMOISTURE DENSITY - F241078-1431520113.9
98
88.9 28.1 95
24.7
113.0 90.2 25.3
3 D.4/15.5 FG 1 6
2 C.8/15.5 FG 1 6
113.6 91.1
1 C.3/15.5 FG 1 6
Cloudy
97
1431520
Project:121 Commerce Center Addition (Lot 1)Project Number:F241078
Client:GTIS Acquisitions, LLC Service Date:07/26/2024
5058 Brush Creek Rd
Fort Worth, TX 76119
www.TeamUES.com
TBPELS Firm No. 813
In-Place Nuclear Density
Test Report
Work Order Number:
787 Seventh Avenue, 50th Floor Report Date:7/31/2024
New York, NY 10019 Weather:
Off Genesis Way and Enchanted Way Technician:Reyes, Ruben
Grapevine, Texas Page Number:1 of 1
Material Information Laboratory Data
13Light Brown and Tan Clay 93.2
Project Specifications
Mat.
No.
Optimum
Moisture
(%)
Max Dry
Weight
(pcf)
Proctor
Report No.
Moisture
Min. (%) Max.
Compaction
Min. (%) Max.Material Description/Classification PI
-2 2 9506L
General Location
Area:Building Pad
100126.3
Field Test Data
Test
No.Test Location Lift/
Depth
Mat.
No.
Probe
Depth
(in.)
Wet
Density
(pcf)
Dry
Density
(pcf)
Percent
Moisture
(%)
Percent
Compaction
(%)
Gauge Information Non-compliant results are indicated by an asterisk(*) if
applicable.
Serial No:4453 Manufacturer:Instrotek Model:(D): 2270 (M):731Standard Count:
Remarks:
Respectfully Submitted,
Ronnie Yeoman
approval. Test results and reports apply only to the samples tested and/or observed, and are not indicative of the qualities of apparently identical or similar specimens. Technician time is from portal to portal. MF-010(8/2/2016)
Environmental Consulting & Permit Support | Geotechnical Engineering | Materials Testing & Special Inspections | Geophysical Technologies
This report is in general compliance with one or more of the following technical standards: D6938-15
Our test results and reports are for the exclusive use of the Client (and designated recipients) and shall not be reproduced and/or distributed except with express approval of UES. The use of our name and test results must receive our written
Project Manager
UES / Riner Engineering