Loading...
HomeMy WebLinkAboutDENSITY TESTING -F241078-1395468approval. Test results and reports apply only to the samples tested and/or observed, and are not indicative of the qualities of apparently identical or similar specimens. Technician time is from portal to portal. MF-010(8/2/2016) Environmental Consulting & Permit Support | Geotechnical Engineering | Materials Testing & Special Inspections | Geophysical Technologies This report is in general compliance with one or more of the following technical standards: D6938-15 Our test results and reports are for the exclusive use of the Client (and designated recipients) and shall not be reproduced and/or distributed except with express approval of UES. The use of our name and test results must receive our written Project Manager UES / Riner Engineering Ronnie Yeoman 14 Remarks: FG-2.5 1 6 Respectfully Submitted, Gauge Information Non-compliant results are indicated by an asterisk(*) if applicable. Serial No:2486 Manufacturer:Humboldt Model:5001EZ 13 122.6 98.8 24.1 94 (D): 2456 (M):438Standard Count: 121.9 123.4 123.3 25.0 93 15 A.5/18.5 Field Test Data Test No.Test Location Lift/ Depth Mat. No. Probe Depth (in.) Wet Density (pcf) Dry Density (pcf) Percent Moisture (%) Percent Compaction (%) 101.0 22.1 97.5 D.5/18 FG-3.0 1 6 B.5/18 FG-3.0 1 6 123.4 4 923 General Location Area:Building Pad 96118.0 Project Specifications Mat. No. Optimum Moisture (%) Max Dry Weight (pcf) Proctor Report No. Moisture Min. (%) Max. Compaction Min. (%) Max.Material Description/Classification PI Material Information Laboratory Data 39Dark Brown and Brown Sandy Clay 105.3 New York, NY 10019 Weather: Off Genesis Way and Enchanted Way Technician:Torres, Jorge Grapevine, Texas Page Number:1 of 3 24.0 22.6 1395468 Project:121 Commerce Center Addition (Lot 1)Project Number:F241078 Client:GTIS Acquisitions, LLC Service Date:05/24/2024 5058 Brush Creek Rd Fort Worth, TX 76119 www.TeamUES.com TBPELS Firm No. 813 In-Place Nuclear Density Test Report Work Order Number: 787 Seventh Avenue, 50th Floor Report Date:5/31/2024 1 6 Clear 98.2 25.7 93 24.3 94 93 25.2 93 96 93 99.3 11 D.5/18.5 FG-3.0 1 6 12 E.5/18.5 FG-3.0 1 6 123.3 98.3 25.4 3 C.5/18.5 FG-3.5 1 6 2 B.5/18.5 FG-3.5 1 6 123.0 96.9 1 A.5/18.5 FG-3.5 1 6 10 C.5/18.5 FG-3.0 1 6 6 122.2 122.1 98.5 99.7 123.2 98.4 9 B.5/18.5 FG-3.0 1 6 8 A.5/18.5 FG-3.0 1 7 D.5/18 FG-3.5 6 B.5/18 FG-3.5 1 122.3 123.4 100.5 22.8 95 92 99.0 23.5 94 26.9 6 4 D.5/18.5 FG-3.5 1 6 5 E.5/18.5 FG-3.5 1 6 92 94 95 23.2 94122.1 122.0 122.6 96.8 26.7 97.9 24.6 99.1 The linked image cannot be displayed. The file may have been moved, renamed, or deleted. Verify that the link points to the correct file and location. Client:GTIS Acquisitions, LLC Service Date:05/24/2024 5058 Brush Creek Rd Fort Worth, TX 76119 www.TeamUES.com TBPELS Firm No. 813 In-Place Nuclear Density Test Report 787 Seventh Avenue, 50th Floor Report Date:5/31/2024 New York, NY 10019 Weather:Clear Work Order Number:1395468 Project:121 Commerce Center Addition (Lot 1)Project Number:F241078 Off Genesis Way and Enchanted Way Technician:Torres, Jorge Grapevine, Texas Page Number:2 of 3 Material Description/Classification PI Dark Brown and Brown Sandy Clay 39 Material Information Laboratory Data Project Specifications Moisture Min. (%) Max. Compaction Min. (%) Max. 1 3 18.0 105.3 4 Mat. No. Proctor Report No. Optimum Moisture (%) Max Dry Weight (pcf) 92 96 General Location Area:Building Pad Field Test Data Test No.Test Location Lift/ Depth Mat. No. Probe Depth (in.) Wet Density (pcf) Dry Density (pcf) Percent Moisture (%) Percent Compaction (%) 24.6 16 B.5/18.5 FG-2.5 1 6 123.3 100.2 23.1 95 94 18 D.5/18.5 FG-2.5 1 6 122.7 97.5 17 C.5/18.5 FG-2.5 1 6 122.9 98.6 100.8 22.3 96 25.8 93 9419E.5/18.5 FG-2.5 1 6 122.1 98.5 24.0 122.2 20 B.5/18 FG-2.5 1 6 123.3 93 97.9 24.8 93 22 A.5/18.5 FG-2.0 1 6 21 D.5/18 FG-2.5 1 6 123.0 98.1 25.4 118.9 24 C.5/18.5 FG-2.0 1 6 23 B.5/18.5 FG-2.0 1 6 97.4 22.1 92 123.0 99.0 24.2 94 26 E.5/18.5 FG-2.0 1 6 25 D.5/18.5 FG-2.0 1 6 98.8 23.8 94 123.4 97.3 26.8 92 122.3 28 D.5/18 FG-2.0 1 6 27 B.5/18 FG-2.0 1 6 100.4 23.5 95 123.1 96.9 27.0 92 124.0 30 B.5/18.5 FG-1.5 1 6 29 A.5/18.5 FG-1.5 1 6 98.2 22.7 93 120.4 97.6 23.4 93 120.5 (D): 2456 (M):438 Remarks: Gauge Information Non-compliant results are indicated by an asterisk(*) if applicable. Serial No:2486 Manufacturer:Humboldt Model:5001EZ Standard Count: Respectfully Submitted, approval. Test results and reports apply only to the samples tested and/or observed, and are not indicative of the qualities of apparently identical or similar specimens. Technician time is from portal to portal. MF-010(8/2/2016) Environmental Consulting & Permit Support | Geotechnical Engineering | Materials Testing & Special Inspections | Geophysical Technologies This report is in general compliance with one or more of the following technical standards: D6938-15 Our test results and reports are for the exclusive use of the Client (and designated recipients) and shall not be reproduced and/or distributed except with express approval of UES. The use of our name and test results must receive our written UES / Riner Engineering Ronnie Yeoman Project Manager The linked image cannot be displayed. The file may have been moved, renamed, or deleted. Verify that the link points to the correct file and location. Client:GTIS Acquisitions, LLC Service Date:05/24/2024 5058 Brush Creek Rd Fort Worth, TX 76119 www.TeamUES.com TBPELS Firm No. 813 In-Place Nuclear Density Test Report 787 Seventh Avenue, 50th Floor Report Date:5/31/2024 New York, NY 10019 Weather:Clear Work Order Number:1395468 Project:121 Commerce Center Addition (Lot 1)Project Number:F241078 Off Genesis Way and Enchanted Way Technician:Torres, Jorge Grapevine, Texas Page Number:3 of 3 Material Description/Classification PI Dark Brown and Brown Sandy Clay 39 Material Information Laboratory Data Project Specifications Moisture Min. (%) Max. Compaction Min. (%) Max. 1 3 18.0 105.3 4 Mat. No. Proctor Report No. Optimum Moisture (%) Max Dry Weight (pcf) 92 96 General Location Area:Building Pad Field Test Data Test No.Test Location Lift/ Depth Mat. No. Probe Depth (in.) Wet Density (pcf) Dry Density (pcf) Percent Moisture (%) Percent Compaction (%) 26.8 31 C.5/18.5 FG-1.5 1 6 123.4 99.2 24.4 94 92 33 E.5/18.5 FG-1.5 1 6 123.3 99.7 32 D.5/18.5 FG-1.5 1 6 122.7 96.8 98.4 26.4 93 23.7 95 9334B.5/18 FG-1.5 1 6 122.0 97.5 25.1 123.3 35 D.5/18 FG-1.5 1 6 124.4 92 100.6 22.6 96 37 B.5/18.5 FG-1.0 1 6 36 A.5/18.5 FG-1.0 1 6 123.0 96.8 27.1 123.7 39 D.5/18.5 FG-1.0 1 6 38 C.5/18.5 FG-1.0 1 6 99.5 24.3 94 122.4 97.3 25.8 92 41 B.5/18 FG-1.0 1 6 40 E.5/18.5 FG-1.0 1 6 97.3 26.3 92 124.1 100.1 24.0 95 122.9 42 D.5/18 FG-1.0 1 6 96.9 27.2 92123.3 (D): 2456 (M):438 Remarks: Gauge Information Non-compliant results are indicated by an asterisk(*) if applicable. Serial No:2486 Manufacturer:Humboldt Model:5001EZ Standard Count: Respectfully Submitted, approval. Test results and reports apply only to the samples tested and/or observed, and are not indicative of the qualities of apparently identical or similar specimens. Technician time is from portal to portal. MF-010(8/2/2016) Environmental Consulting & Permit Support | Geotechnical Engineering | Materials Testing & Special Inspections | Geophysical Technologies This report is in general compliance with one or more of the following technical standards: D6938-15 Our test results and reports are for the exclusive use of the Client (and designated recipients) and shall not be reproduced and/or distributed except with express approval of UES. The use of our name and test results must receive our written UES / Riner Engineering Ronnie Yeoman Project Manager The linked image cannot be displayed. The file may have been moved, renamed, or deleted. Verify that the link points to the correct file and location.