Loading...
HomeMy WebLinkAboutDENSITY TESTING -F241078-1483645100 99 21.9 98116.1 97 95.6 21.9 98115.6 115.5 121.3 97.0 22.8 95.6 23.1 96114.4 93.8 22.5 99 121.5 121.9 97.9 22.7 97.3 2 Ne Corner of Building 20' W FG-1.0 1 8 3 ES of Building 10' W of of Building north entrance FG-1.0 1 8 4 ES of Building 20' W of Building north entrance FG-1.0 1 8 5 ES of Building 30' W of Building north entrance FG-1.0 1 115.2 94.7 22.0 115.4 95.3 22.3 96.1 8 9 Northside of Building 50' E FG-1.0 1 8 6 ES of Building 50' W of Building north entrance FG-1.0 1 8 7 Northside of Building 10' E FG-1.0 1 8 8 Northside of Building 30' E FG-1.0 1 8 8 1483645 1 97 98 22.1 5058 Brush Creek Rd Fort Worth, TX 76119 www.TeamUES.com TBPELS Firm No. 813 In-Place Nuclear Density Test Report Client:GTIS Acquisitions, LLC Service Date:10/22/2024 787 Seventh Avenue, 50th Floor Report Date:11/1/2024 Grapevine, Texas Page Number:1 of Project:121 Commerce Center Addition (Lot 1)Project Number:F241078 Off Genesis Way and Enchanted Way Technician:Mitchell, Ebony New York, NY 10019 Weather:Clear Work Order Number: Project Specifications Mat. No. Optimum Moisture (%) Max Dry Weight (pcf) Proctor Report No. Moisture Min. (%) Max. Compaction Min. (%) Max.Material Description/Classification PI Material Information Laboratory Data 38Dark Brown Clay with Sand 95 100121.4 98.0 0 4 Percent Compaction (%) 1 Ne Corner of Building 10' W FG-1.0 1 General Location Area:NE corner of building /eastside of Building/Northside of building 405 Remarks: Field Test Data Test No.Test Location Lift/ Depth Mat. No. Probe Depth (in.) Wet Density (pcf) Dry Density (pcf) Percent Moisture (%) Gauge Information Non-compliant results are indicated by an asterisk(*) if applicable. Serial No:9941 Manufacturer:Humboldt Model:5001EZ UES / Riner Engineering approval. Test results and reports apply only to the samples tested and/or observed, and are not indicative of the qualities of apparently identical or similar specimens. Technician time is from portal to portal. MF-010(8/2/2016) Environmental Consulting & Permit Support | Geotechnical Engineering | Materials Testing & Special Inspections | Geophysical Technologies This report is in general compliance with one or more of the following technical standards: D6938-15 Our test results and reports are for the exclusive use of the Client (and designated recipients) and shall not be reproduced and/or distributed except with express approval of UES. The use of our name and test results must receive our written Ronnie Yeoman Project Manager Respectfully Submitted, Standard Count:(D): 2876 (M):