Loading...
HomeMy WebLinkAboutSFRA2025-001055REV SHEET NAME SHEET SIZE SHEET NUMBER JA M E S G R A V A T T RE S I D E N C E 84 0 E T E X A S S T , GR A P E V I N E , TX 7 6 0 5 1 ANSI B 11" X 17" DATEDESCRIPTION REVISIONS PROJECT NAME & ADDRESS DRAWN BY ESR 03/18/2025INITIAL CMS RENEWABLE LLC 2100 N HWY 360 #1004, GRAND PRAIRIE, TX 75050, USA PHONE: +14694285563 EMAIL: edgar@cmsrenewable.com LICENSE NO: #35493 ELECTRICAL LICENSE NO: #213982 PROJECT DATA GENERAL NOTES VICINITY MAP SHEET INDEX CODE REFERENCES HOUSE PHOTO COVER SHEET PV-1 PHOTOVOLTAIC ROOF MOUNT SYSTEM 40 MODULES-ROOF MOUNTED - 17.800 KW DC, 17.600 KW AC 840 E TEXAS ST, GRAPEVINE, TX 76051 PROJECT ADDRESS 840 E TEXAS ST, GRAPEVINE, TX 76051 OWNER:JAMES GRAVATT DESIGNER:ESR NEW SYSTEM: 17.800 KW DC ROOF MOUNT SOLAR PV SYSTEM WITH 40 VSUN SOLAR VSUN445-144MH 445W PV MODULES WITH 01 SOLAREDGE SE10000H-US (240V) INVERTER AND 01 SOLAREDGE SE7600H-US (240V) INVERTER 40 SOLAREDGE S500 POWER OPTIMIZERS AUTHORITIES HAVING JURISDICTION: BUILDING: CITY OF GRAPEVINE ZONING: CITY OF GRAPEVINE UTILITY: ONCOR PROJECT TO COMPLY WITH THE FOLLOWING: 2020 NATIONAL ELECTRICAL CODE (NEC) 2021 INTERNATIONAL RESIDENTIAL CODE (IRC) 2021 INTERNATIONAL BUILDING CODE (IBC) 2021 INTERNATIONAL FIRE CODE (IFC) 2021 INTERNATIONAL ENERGY CONSERVATION CODE (IECC) 1.ALL COMPONENTS ARE UL LISTED AND NEC CERTIFIED, WHERE WARRANTED. 2.THE SOLAR PV SYSTEM WILL BE INSTALLED IN ACCORDANCE WITH ARTICLE 690 OF THE NEC 2020. 3.THE UTILITY INTERCONNECTION APPLICATION MUST BE APPROVED AND PV SYSTEM INSPECTED PRIOR TO PARALLEL OPERATION. 4.ALL CONDUCTORS OF A CIRCUIT, INCLUDING THE EGC, MUST BE INSTALLED IN THE SAME RACEWAY, OR CABLE, OR OTHERWISE RUN WITH THE PV ARRAY CIRCUIT CONDUCTORS WHEN THEY LEAVE THE VICINITY OF THE PV ARRAY. 5.WHERE METALLIC CONDUIT CONTAINING DC CONDUCTORS IS USED INSIDE THE BUILDING, IT SHALL BE IDENTIFIED AS "CAUTION: SOLAR CIRCUIT" EVERY 10FT. 6.HEIGHT OF THE AC DISCONNECT SHALL NOT EXCEED 6'-7" PER NEC CODE 240.24. 7.A GROUNDING ELECTRODE SYSTEM IN ACCORDANCE WITH NEC 2020 690.47 AND 250.50 THROUGH 60 AND 250-166 SHALL BE PROVIDED. PER NEC GROUNDING ELECTRODE SYSTEM OF EXISTING BUILDING MAY BE USED AND BONDED TO THE SERVICE ENTRANCE. IF EXISTING SYSTEM IS INACCESSIBLE OR INADEQUATE A SUPPLEMENTAL GROUNDING ELECTRODE WILL BE USED AT THE INVERTER LOCATION CONSISTING OF A UL LISTED 8 FT. GROUND ROD WITH ACORN CLAMP. GROUNDING ELECTRODE CONDUCTORS SHALL BE NO LESS THAN #8 AWG AND NO LARGER THAN #6 AWG COPPER AND BONDED TO THE EXISTING GROUNDING ELECTRODE TO PROVIDE FOR A COMPLETE SYSTEM. 8.PHOTOVOLTAIC MODULES ARE TO BE CONSIDERED NON-COMBUSTIBLE. 9.PHOTOVOLTAIC INSTALLATION WILL NOT OBSTRUCT ANY PLUMBING, MECHANICAL, OR BUILDING ROOF VENTS. 10.ALL WIRING MUST BE PROPERLY SUPPORTED BY DEVICES OR MECHANICAL MEANS DESIGNED AND LISTED FOR SUCH USE. WIRING MUST BE PERMANENTLY AND COMPLETELY HELD OFF THE ROOF SURFACE. 11.ALL SIGNAGE TO BE PLACED IN ACCORDANCE WITH THE LOCAL BUILDING CODE. IF EXPOSED TO SUNLIGHT, IT SHALL BE UV RESISTANT. ALL PLAQUES AND SIGNAGE WILL BE INSTALLED AS REQUIRED BY THE NEC AND AHJ. 12.INVERTER(S) USED IN UNGROUNDED SYSTEM SHALL BE UL 1741 LISTED. 13.THE INSTALLATION OF EQUIPMENT AND ALL ASSOCIATED WIRING AND INTERCONNECTION SHALL BE PERFORMED ONLY BY QUALIFIED PERSONS [NEC 690.4(C)] 14.ALL OUTDOOR EQUIPMENT SHALL BE NEMA 3R RATED (OR BETTER), INCLUDING ALL ROOF MOUNTED TRANSITION BOXES AND SWITCHES. 15.ALL EQUIPMENT SHALL BE PROPERLY GROUNDED AND BONDED IN ACCORDANCE WITH NEC ARTICLE 250. 16.SYSTEM GROUNDING SHALL BE IN ACCORDANCE WITH NEC 690.41. 17.PV SYSTEM CIRCUITS INSTALLED ON OR IN BUILDINGS SHALL INCLUDE A RAPID SHUTDOWN FUNCTION IN ACCORDANCE WITH NEC 690.12 18.DISCONNECTING MEANS SHALL BE LOCATED IN A VISIBLE, READILY ACCESSIBLE LOCATION WITHIN THE PV SYSTEM EQUIPMENT OR A MAXIMUM OF 10 FEET AWAY FROM THE SYSTEM [NEC 690.13(A)] 19.ALL WIRING METHODS SHALL BE IN ACCORDANCE WITH NEC 690.31 20.WORK CLEARANCES AROUND ELECTRICAL EQUIPMENT WILL BE MAINTAINED PER NEC 110.26(A)(1), 110.26(A)(2) AND 110.26(A)(3). 21.ROOFTOP MOUNTED PHOTOVOLTAIC PANELS AND MODULES SHALL BE TESTED, LISTED & IDENTIFIED IN ACCORDANCE WITH UL1703 22.ELECTRICAL CONTRACTOR TO PROVIDE CONDUIT EXPANSION JOINTS AND ANCHOR CONDUIT RUNS AS REQUIRED PER NEC. 23.IN ACCORDANCE WITH 2021 IFC 1205.5, 2018 IFC 1204.4, AND 2015 IFC 605.11.2 A CLEAR, BRUSH-FREE AREA OF 10 FEET(3048 MM) SHALL BE REQUIRED FOR GROUND-MOUNTED PHOTOVOLTAIC ARRAYS. 24. PANEL LAYOUT ORIENTATION IS SUBJECT TO CHANGE ON DESIGNED MOUNTING PLANES. CONTRACTOR:CMS RENEWABLE LLC 2100 N HWY 360 #1004, GRAND PRAIRIE, TX 75050, USA PHONE: +14694285563 EMAIL: edgar@cmsrenewable.com LICENSE NO:#35493 ELECTRICAL LICENSE NO: #213982 ESIID: # 10443720002327917 METER NO: # 145 851 046 PV-1 COVER SHEET PV-2 SITE PLAN PV-3 ROOF PLAN & MODULES PV-4 ELECTRICAL PLAN PV-5 STRUCTURAL DETAIL PV-6 ELECTRICAL LINE DIAGRAM PV-7 WIRING CALCULATIONS PV-8 LABELS PV-9 PLACARD PV-10 OPTIMIZER CHART PV-11+ EQUIPMENT SPECIFICATIONS REPLACING DEFECTIVE EXISTING SYSTEM: OLD SYSTEM: 10.440 KW DC ROOF MOUNT SOLAR PV SYSTEM WITH 29 REC SOLAR: REC360AA BLACK 360W PV MODULES WITH 01 SOLAREDGE SE10000H-US (240V) INVERTER AND 29 SOLAREDGE S440 POWER OPTIMIZERS SCOPE: 84'-7" 18 2 ' - 6 " 18 2 ' - 6 " 81'-9" UM MS P SL C IN V IN V AC D <10 FT. REV SHEET NAME SHEET SIZE SHEET NUMBER JA M E S G R A V A T T RE S I D E N C E 84 0 E T E X A S S T , GR A P E V I N E , TX 7 6 0 5 1 ANSI B 11" X 17" DATEDESCRIPTION REVISIONS PROJECT NAME & ADDRESS DRAWN BY ESR 03/18/2025INITIAL CMS RENEWABLE LLC 2100 N HWY 360 #1004, GRAND PRAIRIE, TX 75050, USA PHONE: +14694285563 EMAIL: edgar@cmsrenewable.com LICENSE NO: #35493 ELECTRICAL LICENSE NO: #213982 PROJECT DESCRIPTION: SITE PLAN 40 X VSUN SOLAR VSUN445-144MH 445W PV MODULES ROOF MOUNTED SOLAR PHOTOVOLTAIC MODULES DC SYSTEM SIZE: 40 x 445W = 17.800KW DC AC SYSTEM SIZE: 01 x 10000W + 01 x 7600W = 17.600KW AC PV-2 EQUIPMENT SUMMARY 40 VSUN SOLAR VSUN445-144MH 445W PV MODULES 01 SOLAREDGE SE10000H-US (240V) INVERTER 01 SOLAREDGE SE7600H-US (240V) INVERTER 40 SOLAREDGE S500 POWER OPTIMIZERS 1 SITE PLAN SCALE: 1"=20'-0"PV-2 ROOF #3 (03) VSUN SOLAR VSUN445-144MH 445W PV MODULES WITH SOLAREDGE S500 POWER OPTIMIZERS ROOF #1 (08) VSUN SOLAR VSUN445-144MH 445W PV MODULES WITH SOLAREDGE S500 POWER OPTIMIZERS ROOF ARRAY AREA #1:- 190.24 SQ FT. ROOF ARRAY AREA #2:- 166.46 SQ FT. ROOF ARRAY AREA #3:- 71.34 SQ FT. ROOF ARRAY AREA #4:- 95.12 SQ FT. ROOF ARRAY AREA #5:- 166.46 SQ FT. ROOF ARRAY AREA #6:- 214.02 SQ FT. ROOF ARRAY AREA #7:- 47.56 SQ FT. ROOF #4 (04) VSUN SOLAR VSUN445-144MH 445W PV MODULES WITH SOLAREDGE S500 POWER OPTIMIZERS ROOF #2 (07) VSUN SOLAR VSUN445-144MH 445W PV MODULES WITH SOLAREDGE S500 POWER OPTIMIZERS (N) SOLAREDGE SE10000H-US (240V) INVERTER (E) UTILITY METER (N) VISIBLE, LOCKABLE, LABELED FUSED PV AC DISCONNECT (E) MAIN SERVICE PANEL (OUTSIDE) METER NO # 145 851 046 ESID # 10443720002327917 (E) GATE - EXISTING PV MODULE WHICH IS REMOVABLE - NEW PV MODULE PANEL LEGEND EXISTING SYSTEM TO BE REMOVED (29) REC SOLAR: REC360AA BLACK 360W PV MODULES WITH SOLAREDGE S440 POWER OPTIMIZERS NEW SYSTEM: DC SYSTEM SIZE: 40 x 445 = 17.800 kW DC AC SYSTEM SIZE: 01 x 10000W + 01 x 7600W = 17.600KW AC (40) VSUN SOLAR VSUN445-144MH 445W PV MODULES WITH (01) SOLAREDGE SE10000H-US (240V) INVERTER, (01) SOLAREDGE SE76000H-US (240V) INVERTER (40) SOLAREDGE S500 POWER OPTIMIZERS REPLACING DEFECTIVE EXISTING SYSTEM: OLD SYSTEM: 10.440 KW DC ROOF MOUNT (29) REC SOLAR: REC360AA BLACK 360W PV MODULES (01) SOLAREDGE SE10000H-US (240V) INVERTER (29) SOLAREDGE S440 POWER OPTIMIZERS (N) SOLAR LOAD CENTER (E) TREES (N) SOLAREDGE SE7600H-US (240V) INVERTER PROPERTY LINE PR O P E R T Y L I N E PROPERTY LINE PR O P E R T Y L I N E E TEXAS ST EXISTING DRIVEWAY 1-STORY HOUSE ROOF #5 (07) VSUN SOLAR VSUN445-144MH 445W PV MODULES WITH SOLAREDGE S500 POWER OPTIMIZERS ROOF #6 (09) VSUN SOLAR VSUN445-144MH 445W PV MODULES WITH SOLAREDGE S500 POWER OPTIMIZERS ROOF #7 (02) VSUN SOLAR VSUN445-144MH 445W PV MODULES WITH SOLAREDGE S500 POWER OPTIMIZERS (E) CHIMNEY (TYP.) NOTE: VISIBLE, LOCKABLE, LABELED AC DISCONNECT LOCATED ON ACCESSIBLE EXTERIOR WALL WITHIN 10' OF ONCOR METER SOLAR MODULE SPECIFICATIONS MANUFACTURER / MODEL #VSUN SOLAR VSUN445-144MH 445W MODULE VMP 41.20V IMP 10.81A VOC 49.80V ISC 11.42A TEMP. COEFF. VOC -0.286%/°C MODULE DIMENSION 82.99"L x 41.26"W x 1.38"D (In Inch) INVERTER #1 SPECIFICATIONS MANUFACTURER / MODEL #SOLAREDGE SE10000H-US (240V) INVERTER NOMINAL AC POWER 10.000KW NOMINAL INPUT VOLTAGE 240 VAC NOMINAL INPUT CURRENT 42A INVERTER #2 SPECIFICATIONS MANUFACTURER / MODEL #SOLAREDGE SE7600H-US (240V) INVERTER NOMINAL AC POWER 7.600KW NOMINAL INPUT VOLTAGE 240 VAC NOMINAL INPUT CURRENT 32A (E) FENCE MS P 3'-0" 20'-10"8'-11" 3'-1" 17'-4" 7" 4'-0" 9'-4"29'-3"1'-3" MODULE TYPE, DIMENSIONS & WEIGHT SCALE: 3/32" = 1'-0" ROOF PLAN AND MODULES NUMBER OF MODULES = 40 MODULES MODULE TYPE = VSUN SOLAR VSUN445-144MH 445W PV MODULES MODULE WEIGHT = 52.47 LBS / 23.8KG. MODULE DIMENSIONS = 82.99" x 41.26" = 23.78 SF VSUN SOLAR VSUN445-144MH 445W MODULES 82 . 9 9 " 41.26" PV-3 REV SHEET NAME SHEET SIZE SHEET NUMBER JA M E S G R A V A T T RE S I D E N C E 84 0 E T E X A S S T , GR A P E V I N E , TX 7 6 0 5 1 ANSI B 11" X 17" DATEDESCRIPTION REVISIONS PROJECT NAME & ADDRESS DRAWN BY ESR 03/18/2025INITIAL CMS RENEWABLE LLC 2100 N HWY 360 #1004, GRAND PRAIRIE, TX 75050, USA PHONE: +14694285563 EMAIL: edgar@cmsrenewable.com LICENSE NO: #35493 ELECTRICAL LICENSE NO: #213982 1 ROOF PLAN AND MODULES PV-3 MSP - MAIN SERVICE PANEL - VENT, ATTIC FAN (ROOF OBSTRUCTION) - ROOF ATTACHMENT - RAFTER LEGEND ARRAY AREA & ROOF AREA CALC'S TOTAL PV ARRAY AREA (SQ. FT.) TOTAL ROOF AREA (Sq. Ft.) ROOF AREA COVERED BY ARRAY (%) 951.20 3593.22 26 ROOF DESCRIPTION ROOF TYPE ASPHALT SHINGLE ROOF # OF MODULES ROOF PITCH AZIMUTH RAFTER SIZE RAFTER SPACING #1 08 30°180°2"X8"24" #2 07 30°90°2"X8"24" #3 03 30°180°2"X8"24" #4 04 30°270°2"X8"24" #5 07 9°180°2"X8"24" #6 09 30°180°2"X8"24" #7 02 30°270°2"X8"24" - EXISTING PV MODULE WHICH IS REMOVABLE - NEW PV MODULE PANEL LEGEND ROOF #3 (03) VSUN SOLAR VSUN445-144MH 445W PV MODULES WITH SOLAREDGE S500 POWER OPTIMIZERS ROOF #1 (08) VSUN SOLAR VSUN445-144MH 445W PV MODULES WITH SOLAREDGE S500 POWER OPTIMIZERS ROOF #4 (04) VSUN SOLAR VSUN445-144MH 445W PV MODULES WITH SOLAREDGE S500 POWER OPTIMIZERS ROOF #2 (07) VSUN SOLAR VSUN445-144MH 445W PV MODULES WITH SOLAREDGE S500 POWER OPTIMIZERS (N) IRONRIDGE XR 10 RAIL (E) MAIN SERVICE PANEL (OUTSIDE) (133) K2 SYSTEMS SPLICE FOOT XL ATTACHMENTS 18" FIRE SETBACK (TYP.) EXISTING SYSTEM TO BE REMOVED (29) REC SOLAR: REC360AA BLACK 360W PV MODULES WITH SOLAREDGE S440 POWER OPTIMIZERS ROOF #5 (07) VSUN SOLAR VSUN445-144MH 445W PV MODULES WITH SOLAREDGE S500 POWER OPTIMIZERS ROOF #6 (09) VSUN SOLAR VSUN445-144MH 445W PV MODULES WITH SOLAREDGE S500 POWER OPTIMIZERS ROOF #7 (02) VSUN SOLAR VSUN445-144MH 445W PV MODULES WITH SOLAREDGE S500 POWER OPTIMIZERS (E) CHIMNEY (TYP.) ROOF #1 PITCH - 30° AZIM. - 180° ROOF #2 PITCH - 30° AZIM. - 90° ROOF #3 PITCH - 30° AZIM. - 180° ROOF #4 PITCH - 30° AZIM. - 270° ROOF #5 PITCH - 9° AZIM. - 180° ROOF #6 PITCH - 30° AZIM. - 180° 18" FIRE SETBACK 36 " F I R E S E T B A C K 1 8 " F I R E S E T B A C K 1 8 " F I R E S E T B A C K 18" F I R E S E T B A C K 18" F I R E S E T B A C K 18 " F I R E S E T B A C K 18 " F I R E S E T B A C K 1 8 " F I R E S E T B A C K 1 8 " F I R E S E T B A C K 18" F I R E S E T B A C K 18" F I R E S E T B A C K 18" FIRE SETBACK 36" FIRE SETBACK 36 " F I R E S E T B A C K NEW SYSTEM: DC SYSTEM SIZE: 40 x 445 = 17.800 kW DC AC SYSTEM SIZE: 01 x 10000W + 01 x 7600W = 17.600KW AC (40) VSUN SOLAR VSUN445-144MH 445W PV MODULES WITH (01) SOLAREDGE SE10000H-US (240V) INVERTER, (01) SOLAREDGE SE76000H-US (240V) INVERTER AND (40) SOLAREDGE S500 POWER OPTIMIZERS REPLACING DEFECTIVE EXISTING SYSTEM: OLD SYSTEM: 10.440 KW DC ROOF MOUNT (29) REC SOLAR: REC360AA BLACK 360W PV MODULES (01) SOLAREDGE SE10000H-US (240V) INVERTER (29) SOLAREDGE S440 POWER OPTIMIZERS ROOF #7 PITCH - 30° AZIM. - 270° 18" FIRE SETBACK 18" FIRE SETBACK 36" FIRE SETBACK (TYP.) UM MS P SL C IN V IN V AC D <10 FT. JB JB JB JB JB JB JB SCALE: 3/32" = 1'-0" REV SHEET NAME SHEET SIZE SHEET NUMBER JA M E S G R A V A T T RE S I D E N C E 84 0 E T E X A S S T , GR A P E V I N E , TX 7 6 0 5 1 ANSI B 11" X 17" DATEDESCRIPTION REVISIONS PROJECT NAME & ADDRESS DRAWN BY ESR 03/18/2025INITIAL CMS RENEWABLE LLC 2100 N HWY 360 #1004, GRAND PRAIRIE, TX 75050, USA PHONE: +14694285563 EMAIL: edgar@cmsrenewable.com LICENSE NO: #35493 ELECTRICAL LICENSE NO: #213982 PV-4 1 ELECTRICAL PLAN PV-4 (N) JUNCTION BOX (TYP.) UM MSP - UTILITY METER - MAIN SERVICE PANEL - CONDUIT ACD - AC DISCONNECT LEGEND - JUNCTION BOXJB - RAFTER ELECTRICAL PLAN STRING #2 (8 MODULES) STRING #1 (8 MODULES) (N) CONDUIT STRING #3 (8 MODULES) BILL OF MATERIALS EQUIPMENT QTY DESCRIPTION SOLAR PV MODULES 40 VSUN SOLAR VSUN445-144MH 445W PV MODULES INVERTER 1 SOLAREDGE SE10000H-US (240V) INVERTER INVERTER 1 SOLAREDGE SE7600H-US (240V) INVERTER POWER OPTIMIZERS 40 SOLAREDGE S500 POWER OPTIMIZERS JUNCTION BOXES 07 JUNCTION BOXES RAIL 28 IRONRIDGE XR 10 RAIL,168" SILVER SPLICE 8 SPLICE KIT MID MODULE CLAMPS 38 MID MODULE CLAMPS END CLAMPS 84 END CLAMPS / STOPPER SLEEVE ATTACHMENTS 133 K2 SYSTEMS SPLICE FOOT XL ATTACHMENTS GROUND LUGS 21 GROUND LUGS METER NO # 145 851 046 ESID # 10443720002327917 STRING #1/INV #1 STRING #2/INV #1 STRING #3/INV #1 STRING LEGENDS (E) UTILITY METER (N) VISIBLE, LOCKABLE, LABELED FUSED PV AC DISCONNECT (E) MAIN SERVICE PANEL (OUTSIDE) - EXISTING PV MODULE WHICH IS REMOVABLE - NEW PV MODULE PANEL LEGEND STRING #4/INV #2 STRING #4 (8 MODULES) (N) SOLAREDGE SE10000H-US (240V) INVERTER (N) SOLAR LOAD CENTER SLC - SOLAR LOAD CENTER INV - INVERTER (N) SOLAREDGE SE7600H-US (240V) INVERTER NEW SYSTEM: DC SYSTEM SIZE: 40 x 445 = 17.800 kW DC AC SYSTEM SIZE: 01 x 10000W + 01 x 7600W = 17.600KW AC (40) VSUN SOLAR VSUN445-144MH 445W PV MODULES WITH (01) SOLAREDGE SE10000H-US (240V) INVERTER, (01) SOLAREDGE SE76000H-US (240V) INVERTER AND (40) SOLAREDGE S500 POWER OPTIMIZERSSTRING #5/INV #2 NOTE: VISIBLE, LOCKABLE, LABELED AC DISCONNECT LOCATED ON ACCESSIBLE EXTERIOR WALL WITHIN 10' OF ONCOR METER STRING #5 (8 MODULES) EXISTING SYSTEM TO BE REMOVED (29) REC SOLAR: REC360AA BLACK 360W PV MODULES WITH SOLAREDGE S440 POWER OPTIMIZERS E TEXAS ST REPLACING DEFECTIVE EXISTING SYSTEM: OLD SYSTEM: 10.440 KW DC ROOF MOUNT (29) REC SOLAR: REC360AA BLACK 360W PV MODULES (01) SOLAREDGE SE10000H-US (240V) INVERTER (29) SOLAREDGE S440 POWER OPTIMIZERS(40) SOLAREDGE S500 POWER OPTIMIZERS LOCATED UNDER EACH MODULE REV SHEET NAME SHEET SIZE SHEET NUMBER JA M E S G R A V A T T RE S I D E N C E 84 0 E T E X A S S T , GR A P E V I N E , TX 7 6 0 5 1 ANSI B 11" X 17" DATEDESCRIPTION REVISIONS PROJECT NAME & ADDRESS DRAWN BY ESR 03/18/2025INITIAL CMS RENEWABLE LLC 2100 N HWY 360 #1004, GRAND PRAIRIE, TX 75050, USA PHONE: +14694285563 EMAIL: edgar@cmsrenewable.com LICENSE NO: #35493 ELECTRICAL LICENSE NO: #213982 PV-5 STRUCTURAL DETAIL (2) 5/16"x3.5" SS LAG BOLT WITH MIN 2.5" THREAD EMBEDMENT, SEALED PENETRATION,K2 SYSTEMS- SPLICE FOOT XL, ALUMN. "L" BRACKET W/3/8" SS BOLT & NUT GROUNDING END/MID CLAMP (N) IRONRIDGE XR10 RAIL (E) ASPHALT SHINGLE ROOF 2"X8" RAFTER @ 24" O.C (N) PV MODULE (N) K2 SYSTEMS SPLICE FOOT XL ATTACHMENTS ATTACHMENT DETAIL (ENLARGED VIEW) SCALE: NTSPV-5 2 1 STRUCTURAL ATTACHMENT (SIDE VIEW) SCALE: N.T.SPV-5 (N) PV MODULE SEE (2/PV-5) FOR ENLARGED VIEW (E) ASPHALT SHINGLE ROOF6 " (N) BND T-BOLT & NUT 3/8"X1" SS G N 60A/2P 40A/2P (N) SOLAR LOAD CENTER 240V, 1ɸ, 3W 125A RATED, NEMA 3R L1 L2 N GL1L2 L1 L2 N G 4 = DC SOLAREDGE TECHNOLOGIES LTD. SE10000H-US (240V) INPUT: 240 VAC, 42A 99% CEC WEIGHTED EFFICIENCY NEMA 3R, UL LISTED, INTERNAL GFDI WITH INTEGRATED DC DISCONNECT AC -+ -++ -+ +++--- 2 -+ - 1 3 = = = = = = = = = = -+ -++ -+ +++--- 2 -+ - 1 3 = = = = = = = = = = 1 STRING #4 STRING #5 SOLAREDGE POWER OPTIMIZERS S500 RATED DC INPUT POWER - 500 WATTS MAXIMUM INPUT VOLTAGE - 60 VDC MPPT RANGE - 8 TO 60 VDC MAXIMUM SHORT CIRCUIT CURRENT - 15 ADC MAXIMUM OUTPUT CURRENT - 15 ADC STRING LIMITATIONS - 8 TO 25 OPTIMIZERS, 5700 WATTS STC PER STRING MAXIMUM (16) VSUN SOLAR VSUN445-144MH 445W PV MODULES 7 8 7 8 = DC SOLAREDGE TECHNOLOGIES LTD. SE7600H-US (240V) OUTPUT: 240 VAC, 32A 99% CEC WEIGHTED EFFICIENCY NEMA 3R, UL LISTED, INTERNAL GFDI WITH INTEGRATED DC DISCONNECT AC JUNCTION BOX 600V, NEMA 3R, UL LISTED 2 G + - + - -+-+ -+-+ 3A 3 N G INVERTER #1 INVERTER #2 LOAD LINE GN 100A Fuses FUSED PV AC DISCONNECT 240V, 1ɸ, 3W 100A RATED NEMA 3R -+ -++ -+ +++--- 2 -+ - 1 3 = = = = = = = = = = -+ -++ -+ +++--- 2 -+ - 1 3 = = = = = = = = = = -+ -++ -+ +++--- 2 -+ - 1 3 = = = = = = = = = = 1 STRING #1 STRING #2 STRING #3 7 8 (24) VSUN SOLAR VSUN445-144MH 445W PV MODULES 7 8 7 8 JUNCTION BOX 600V, NEMA 3R, UL LISTED 2 G + - + - + - -+-+ -+-+ -+-+ SOLAREDGE POWER OPTIMIZERS S500 RATED DC INPUT POWER - 500 WATTS MAXIMUM INPUT VOLTAGE - 60 VDC MPPT RANGE - 8 TO 60 VDC MAXIMUM SHORT CIRCUIT CURRENT - 15 ADC MAXIMUM OUTPUT CURRENT - 15 ADC STRING LIMITATIONS - 8 TO 25 OPTIMIZERS, 5700 WATTS STC PER STRING MAXIMUM VISIBLE, LOCKABLE, LABELED AC DISCONNECT LOCATED ON ACCESSIBLE EXTERIOR WALL WITHIN 10' OF ONCOR METER (N) #6 BARE CU VIA IRREVERSIBLE CRIMP TO EXISTING GROUNDING ELECTRODE SYSTEM L1 L2 5 N SUPPLY SIDE CONNECTION REF 2020 NEC 705.11(D), 230.46 AND IN ACCORDANCE WITH 110.14, 300.5(E),300.13 AND 300.15 M BI-DIRECTIONAL UTILITY METER 1ɸ, 3-W, 120/240V METER NO # 145 851 046 (ONCOR UTILITY) NL2L1 TO UTILITY GRID LINE LOAD LINE SIDE INTERCONNECTION AT MAIN PANEL PER ART. 705.11, 230.82(6) G N G N GEC 200A/2P (E) MAIN SERVICE PANEL, 200A RATED, 240V EXISTING GROUNDING ELECTRODE SYSTEM TO EARTH REF. NEC 250.52, 250.53(A) (SEE GROUNDING & GENERAL NOTES #8 & 9) (E) MAIN BREAKER TO HOUSE 240V, 200A/2P REV SHEET NAME SHEET SIZE SHEET NUMBER JA M E S G R A V A T T RE S I D E N C E 84 0 E T E X A S S T , GR A P E V I N E , TX 7 6 0 5 1 ANSI B 11" X 17" DATEDESCRIPTION REVISIONS PROJECT NAME & ADDRESS DRAWN BY ESR 03/18/2025INITIAL CMS RENEWABLE LLC 2100 N HWY 360 #1004, GRAND PRAIRIE, TX 75050, USA PHONE: +14694285563 EMAIL: edgar@cmsrenewable.com LICENSE NO: #35493 ELECTRICAL LICENSE NO: #213982 SCALE: NTS PV-6 DC SYSTEM SIZE: 40 x 445W = 17.800KW DC AC SYSTEM SIZE: 01 x 10000W + 01 x 7600W = 17.600KW AC (40) VSUN SOLAR VSUN445-144MH 445W PV MODULES WITH (01) SOLAREDGE SE10000H-US (240V) INVERTER, (01) SOLAREDGE SE7600H-US (240V) INVERTER AND (40) SOLAREDGE S500 POWER OPTIMIZERS ARE LOCATED UNDER EACH MODULE (05) STRINGS OF 08 MODULES ARE CONNECTED IN SERIES 1 ELECTRICAL LINE DIAGRAM PV-6 ELECTRICAL LINE DIAGRAM METER NO # 145 851 046 ESID # 10443720002327917 QTY CONDUCTOR INFORMATION CONDUIT TYPE CONDUIT SIZE (10)CU#10AWG - N/A N/A(1)1 CU #6AWG -BARE COPPER IN FREE AIR PV WIRE (POSITIVE & NEGATIVE) (10)CU#10AWG - EMT, LFMC OR PVC 3/4"(1)2 CU#10AWG -THWN-2 GND THWN-2 (+, -) (EXTERIOR) (3) (1)THWN-2 OR THHN GND THWN-2 OR THHN L1, L2 & NCU #3AWG - CU #6AWG -4 1"EMT, LFMC OR PVC (2) (1) CU #3AWG - CU #3AWG - 1"EMT, LFMC OR PVC5 (3) (1)THWN-2 OR THHN GND THWN-2 OR THHN L1, L2 & NCU #8AWG - CU #10AWG - 3A EMT, LFMC OR PVC (3) (1)THWN-2 OR THHN GND THWN-2 OR THHN L1, L2 & NCU #6AWG - CU #10AWG - 3 EMT, LFMC OR PVC 3/4" 3/4" THWN-2 OR THHN N THWN-2 OR THHN L1 & L2 INTERCONNECTION NOTES: 1. INTERCONNECTION SIZING, LIMITATIONS AND COMPLIANCE DETERMINED IN ACCORDANCE WITH [NEC 705.12], AND [NEC 690.59]. 2. GROUND FAULT PROTECTION IN ACCORDANCE WITH [NEC 215.9], [NEC 230.95]. 3. ALL EQUIPMENT TO BE RATED FOR BACKFEEDING. 4. PV BREAKER TO BE POSITIONED AT THE OPPOSITE END OF THE BUSBAR RELATIVE TO THE MAIN BREAKER. DISCONNECT NOTES: 1. DISCONNECTING SWITCHES SHALL BE WIRED SUCH THAT WHEN THE SWITCH IS OPENED THE CONDUCTORS REMAINING LIVE ARE CONNECTED TO THE TERMINALS MARKED “LINE SIDE” (TYPICALLY THE UPPER TERMINALS) 2. AC DISCONNECT MUST BE ACCESSIBLE TO QUALIFIED UTILITY PERSONNEL, BE LOCKABLE, AND BE A VISIBLE-BREAK SWITCH 3. DISCONNECT MEANS AND THEIR LOCATION SHALL BE IN ACCORDANCE WITH [NEC 225.31] AND [NEC 225.32]. GROUNDING & GENERAL NOTES: 1. GROUNDING ELECTRODES AND GROUNDING ELECTRODE CONDUCTORS. ADDITIONAL GROUNDING ELECTRODES SHALL BE PERMITTED TO BE INSTALLED IN ACCORDANCE WITH 250.52 AND 250.54.GROUNDING ELECTRODES SHALL BE PERMITTED TO BE CONNECTED DIRECTLY TO THE PV MODULE FRAME(S) OR SUPPORT STRUCTURE PER [NEC 690.47(B)] 2. PV INVERTER IS UNGROUNDED, TRANSFORMER-LESS TYPE. 3. DC GEC AND AC EGC TO REMAIN UNSPLICED, OR SPLICED TO EXISTING ELECTRODE 4. ANY EXISTING WIRING INVOLVED WITH PV SYSTEM CONNECTION THAT IS FOUND TO BE INADEQUATE PER CODE SHALL BE CORRECTED PRIOR TO FINAL INSPECTION. 5. JUNCTION BOXES QUANTITIES, AND PLACEMENT SUBJECT TO CHANGE IN THE FIELD - JUNCTION BOXES DEPICTED ON ELECTRICAL DIAGRAM REPRESENT WIRE TYPE TRANSITIONS. 6. AC DISCONNECT NOTED IN EQUIPMENT SCHEDULE OPTIONAL IF OTHER AC DISCONNECTING MEANS IS LOCATED WITHIN 10' OF SERVICE DISCONNECT. 7. RACEWAYS AND CABLES EXPOSED TO SUNLIGHT ON ROOFTOPS SHOULD BE INSTALLED MORE THAN 7/8" ABOVE THE ROOF USING CONDUIT SUPPORTS. 8. ALL NEW SERVICE INSTALLATIONS AND REPLACEMENTS REQUIRE A SURGE-PROTECTIVE DEVICE (SPD) IN ACCORDANCE WITH [NEC 230.67]. THE SPD SHALL BE TYPE 1 OR TYPE 2 AND IS REQUIRED TO BE AN INTEGRAL PART OF THE SERVICE EQUIPMENT OR LOCATED IMMEDIATELY ADJACENT THERETO. RACKING NOTE: 1.BOND EVERY OTHER RAIL WITH #6 BARE COPPER REPLACING DEFECTIVE EXISTING SYSTEM: OLD SYSTEM: 10.440 KW DC ROOF MOUNT (29) REC SOLAR: REC360AA BLACK 360W PV MODULES (01) SOLAREDGE SE10000H-US (240V) INVERTER (29) SOLAREDGE S440 POWER OPTIMIZERS SOLAR MODULE SPECIFICATIONS MANUFACTURER / MODEL #VSUN SOLAR VSUN445-144MH 445W MODULE VMP 41.20V IMP 10.81A VOC 49.80V ISC 11.42A TEMP. COEFF. VOC -0.286%/°C MODULE DIMENSION 82.99"L x 41.26"W x 1.38"D (In Inch) INVERTER #1 SPECIFICATIONS MANUFACTURER / MODEL #SOLAREDGE SE10000H-US (240V) INVERTER NOMINAL AC POWER 10.000KW NOMINAL INPUT VOLTAGE 240 VAC NOMINAL INPUT CURRENT 42A INVERTER #2 SPECIFICATIONS MANUFACTURER / MODEL #SOLAREDGE SE7600H-US (240V) INVERTER NOMINAL AC POWER 7.600KW NOMINAL INPUT VOLTAGE 240 VAC NOMINAL INPUT CURRENT 32A REV SHEET NAME SHEET SIZE SHEET NUMBER JA M E S G R A V A T T RE S I D E N C E 84 0 E T E X A S S T , GR A P E V I N E , TX 7 6 0 5 1 ANSI B 11" X 17" DATEDESCRIPTION REVISIONS PROJECT NAME & ADDRESS DRAWN BY ESR 03/18/2025INITIAL CMS RENEWABLE LLC 2100 N HWY 360 #1004, GRAND PRAIRIE, TX 75050, USA PHONE: +14694285563 EMAIL: edgar@cmsrenewable.com LICENSE NO: #35493 ELECTRICAL LICENSE NO: #213982 PV-7 PERCENT OF VALUES NUMBER OF CURRENT CARRYING CONDUCTORS IN EMT .80 4-6 .70 7-9 .50 10-20 SOLAR MODULE SPECIFICATIONS MANUFACTURER / MODEL #VSUN SOLAR VSUN445-144MH 445W MODULE VMP 41.20V IMP 10.81A VOC 49.80V ISC 11.42A TEMP. COEFF. VOC -0.286%/°C MODULE DIMENSION 82.99"L x 41.26"W x 1.38"D (In Inch) AMBIENT TEMPERATURE SPECS RECORD LOW TEMP -8°C AMBIENT TEMP (HIGH TEMP 2%)40°C MODULE TEMPERATURE COEFFICIENT OF Voc -0.286%/°C WIRING CALCULATIONS ELECTRICAL NOTES 1.ALL EQUIPMENT TO BE LISTED BY UL OR OTHER NRTL, AND LABELED FOR ITS APPLICATION. 2.ALL CONDUCTORS SHALL BE COPPER, RATED FOR 600 V AND 90 DEGREE C WET ENVIRONMENT. 3.WIRING, CONDUIT, AND RACEWAYS MOUNTED ON ROOFTOPS SHALL BE RINED DIRECTLY TO, AND LOCATED AS CLOSE AS POSSIBLE TO THE NEAREST RIDGE, HIP, OR VALLEY. 4.WORKING CLEARANCES AROUND ALL NEW AND EXISTING ELECTRICAL EQUIPMENT SHALL COMPLY WITH NEC 110.26. 5.DRAWINGS INDICATE THE GENERAL ARRANGEMENT OF SYSTEMS. CONTRACTOR SHALL FURNISH ALL NECESSARY INLETS, SUPPORTS, FITTINGS AND ACCESSORIES TO FULFILL APPLICABLE CODES AND STANDARDS. 6.WHERE SIZES OF JUNCTION BOXES, RACEWAYS, AND CONDUITS ARE NOT SPECIFIED, THE CONTRACTOR SHALL SIZE THEM ACCORDINGLY. 7.ALL WIRE TERMINATIONS SHALL BE APPROPRIATELY LABELED AND READILY VISIBLE. 8.MODULE GROUNDING CLIPS TO BE INSTALLED BETWEEN MODULE FRAME AND MODULE SUPPORT RAIL, PER THE GROUNDING CLIP MANUFACTURER'S INSTRUCTION. 9.MODULE SUPPORT RAIL TO BE BONDED TO CONTINUOUS COPPER G.E.C. VIA WEEB LUG OR ILSCO GBL-4DBT LAY-IN LUG. 10.TEMPERATURE RATINGS OF ALL CONDUCTORS, TERMINATIONS, BREAKERS, OR OTHER DEVICES ASSOCIATED WITH THE SOLAR PV SYSTEM SHALL BE RATED FOR AT LEAST 75 DEGREE C. 11.CONDUIT INSTALLED AT MINIMUM DISTANCE OF 7/8 INCHES ABOVE ROOF .....NEC 310.15(B)(3)(C) INVERTER #1 SPECIFICATIONS MANUFACTURER / MODEL #SOLAREDGE SE10000H-US (240V) INVERTER NOMINAL AC POWER 10.000KW NOMINAL INPUT VOLTAGE 240 VAC NOMINAL INPUT CURRENT 42A INVERTER #2 SPECIFICATIONS MANUFACTURER / MODEL #SOLAREDGE SE7600H-US (240V) INVERTER NOMINAL AC POWER 7.600KW NOMINAL INPUT VOLTAGE 240 VAC NOMINAL INPUT CURRENT 32A REV SHEET NAME SHEET SIZE SHEET NUMBER JA M E S G R A V A T T RE S I D E N C E 84 0 E T E X A S S T , GR A P E V I N E , TX 7 6 0 5 1 ANSI B 11" X 17" DATEDESCRIPTION REVISIONS PROJECT NAME & ADDRESS DRAWN BY ESR 03/18/2025INITIAL CMS RENEWABLE LLC 2100 N HWY 360 #1004, GRAND PRAIRIE, TX 75050, USA PHONE: +14694285563 EMAIL: edgar@cmsrenewable.com LICENSE NO: #35493 ELECTRICAL LICENSE NO: #213982 LABELS PV-8 480 V 27.00 A MAXIMUM VOLTAGE MAXIMUM CIRCUIT CURRENT MAXIMUM RATED INPUT CURRENT OF THE CHARGE CONTROLLER OR DC-TO-DC CONVERTER (IF INSTALLED) LABEL LOCATION: INVERTER CODE REF: NEC 690.7(D) LABEL- 11: TERMINALS ON THE LINE AND LOAD SIDES MAY BE ENERGIZED IN THE OPEN POSITION WARNING! ELECTRICAL SHOCK HAZARD !WARNING DUAL POWER SOURCE SECOND SOURCE IS PHOTOVOLTAIC SYSTEM LABEL LOCATION: PRODUCTION METER UTILITY METER MAIN SERVICE PANEL SUBPANEL CODE REF: NEC 705.30(C) & NEC 690.59 LABEL- 2: TURN OFF PHOTOVOLTAIC AC DISCONNECT PRIOR TO WORKING INSIDE PANEL WARNING! LABEL LOCATION: MAIN SERVICE PANEL SUBPANEL MAIN SERVICE DISCONNECT COMBINER CODE REF: NEC 110.27(C) & OSHA 1910.145 (f) (7) LABEL- 3: SOLAR PV SYSTEM EQUIPPED WITH RAPID SHUTDOWN TURN RAPID SHUTDOWN SWITCH TO THE "OFF" POSITION TO SHUT DOWN PV SYSTEM AND REDUCE SHOCK HAZARD IN THE ARRAY SOLAR ELECTRIC PV PANELS RAPID SHUTDOWN SWITCH FOR SOLAR PV SYSTEM PHOTOVOLTAIC AC DISCONNECT LABEL LOCATION: AC DISCONNECT CODE REF: NEC 690.13(B) LABEL- 7: PHOTOVOLTAIC AC DISCONNECT NOMINAL OPERATING AC VOLATGE 240 V WARNING POWER SOURCE INPUT CONNECTION. DO NOT RELOCATE THIS OVERCURRENT DEVICE ! MAIN PHOTOVOLTAIC SYSTEM DISCONNECT LABEL LOCATION: MAIN SERVICE DISCONNECT (ONLY IF MAIN SERVICE DISCONNECT IS PRESENT) CODE REF: NEC 690.13(B) LABEL- 9: RATED AC INPUT CURRENT LABEL LOCATION: AC DISCONNECT COMBINER MAIN SERVICE PANEL SUBPANEL MAIN SERVICE DISCONNECT CODE REF: NEC 705.20(7) and NEC 690.13(B) LABEL- 1: LABEL LOCATION: MAIN SERVICE PANEL (ONLY IF SOLAR IS BACK-FED) SUBPANEL (ONLY IF SOLAR IS BACK-FED) CODE REF: NEC 705.12 (B)(2) LABEL- 4: LABEL LOCATION: MAIN SERVICE PANEL CODE REF: IFC 605.11.3.1(1) & 690.12(D) LABEL- 5: LABEL LOCATION: AC DISCONNECT CODE REF: NEC 690.12(D)(2) LABEL- 6: LABEL- 8: LABEL LOCATION: MAIN SERVICE PANEL SUBPANEL AC DISCONNECT CODE REF: NEC 690.13(B) 74.00 A INVERTER #1 AC DISCONNECT NOMINAL OPERATING AC VOLATGE 240 V RATED AC INPUT CURRENT LABEL- 10: LABEL LOCATION: MAIN SERVICE PANEL SUBPANEL AC DISCONNECT CODE REF: NEC 690.13(B) 42.00 A INVERTER #2 AC DISCONNECT NOMINAL OPERATING AC VOLATGE 240 V RATED AC INPUT CURRENT LABEL- 12: LABEL LOCATION: MAIN SERVICE PANEL SUBPANEL AC DISCONNECT CODE REF: NEC 690.13(B) 32.00 A 480 V 20.00 A MAXIMUM VOLTAGE MAXIMUM CIRCUIT CURRENT MAXIMUM RATED INPUT CURRENT OF THE CHARGE CONTROLLER OR DC-TO-DC CONVERTER (IF INSTALLED) LABEL LOCATION: INVERTER CODE REF: NEC 690.7(D) LABEL- 13: CAUTION POWER TO THIS SERVICE IS ALSO SUPPLIED FROM ON-SITE SOLAR/WIND GENERATION AC SYSTEM DISCONNECT LABEL LOCATION: AC DISCONNECT LABEL-14: CAUTION ALTERNATIVE POWER SUPPLY AC SYSTEM DISCONNECT LABEL LOCATION: AC DISCONNECT LABEL-15: UM MS P SL C IN V IN V AC D JB JB JB JB JB JB JB REV SHEET NAME SHEET SIZE SHEET NUMBER JA M E S G R A V A T T RE S I D E N C E 84 0 E T E X A S S T , GR A P E V I N E , TX 7 6 0 5 1 ANSI B 11" X 17" DATEDESCRIPTION REVISIONS PROJECT NAME & ADDRESS DRAWN BY ESR 03/18/2025INITIAL CMS RENEWABLE LLC 2100 N HWY 360 #1004, GRAND PRAIRIE, TX 75050, USA PHONE: +14694285563 EMAIL: edgar@cmsrenewable.com LICENSE NO: #35493 ELECTRICAL LICENSE NO: #213982 PLACARD PV-9 JUNCTION BOX (TYP.) DIRECTORY PERMANENT PLAQUE OR DIRECTORY PROVIDING THE LOCATION OF THE SERVICE DISCONNECTING MEANS AND THE PHOTOVOLTAIC SYSTEM. (ALL PLAQUES AND SIGNAGE WILL BE INSTALLED AS INLINED WITHIN: NEC 690.56(B)&(C), [NEC 705.10]) LABELING NOTES: 1. LABELS CALLED IN ACCORDING TO ALL COMMON CONFIGURATIONS. ELECTRICIAN TO DETERMINE EXACT REQUIREMENTS IN THE FIELD PER CURRENT NEC AND LOCAL CODES AND MAKE APPROPRIATE ADJUSTMENTS. 2. LABELING REQUIREMENTS BASED ON THE 2020 NATIONAL ELECTRIC CODE, OSHA STANDARD 19010.145, ANSI Z535. 3. MATERIAL BASED ON THE REQUIREMENTS OF THE AUTHORITY HAVING JURISDICTION. 4. LABELS TO BE OF SUFFICIENT DURABILITY TO WITHSTAND THE ENVIRONMENT INVOLVED [NEC 110.21] 5. LABELS TO BE A MINIMUM LETTER HEIGHT OF 3/8", WHITE ON RED BACKGROUND; REFLECTIVE, AND PERMANENTLY AFFIXED [IFC 605.11.1.1] NEW PV ARRAY SOLAREDGE SE10000H-US (240V) INVERTER UTILITY METER PV AC DISCONNECT MAIN SERVICE PANEL (OUTSIDE) EXISTING PV ARRAY (TO BE REMOVED) SOLAR LOAD CENTER SOLAREDGE SE7600H-US (240V) INVERTER 840 E TEXAS ST, GRAPEVINE, TX 76051 MULTIPLE SOURCES OF POWER CAUTION: REV SHEET NAME SHEET SIZE SHEET NUMBER JA M E S G R A V A T T RE S I D E N C E 84 0 E T E X A S S T , GR A P E V I N E , TX 7 6 0 5 1 ANSI B 11" X 17" DATEDESCRIPTION REVISIONS PROJECT NAME & ADDRESS DRAWN BY ESR 03/18/2025INITIAL CMS RENEWABLE LLC 2100 N HWY 360 #1004, GRAND PRAIRIE, TX 75050, USA PHONE: +14694285563 EMAIL: edgar@cmsrenewable.com LICENSE NO: #35493 ELECTRICAL LICENSE NO: #213982 OPTIMIZER PV-10 11 12 13 14 15 16 17 18 19 20 1-20 2 3 4 21-40 41-60 5 6 7 8 9 10 1 11 12 13 14 15 16 17 18 19 20 OPTIMIZER CHART CHART REV SHEET NAME SHEET SIZE SHEET NUMBER JA M E S G R A V A T T RE S I D E N C E 84 0 E T E X A S S T , GR A P E V I N E , TX 7 6 0 5 1 ANSI B 11" X 17" DATEDESCRIPTION REVISIONS PROJECT NAME & ADDRESS DRAWN BY ESR 03/18/2025INITIAL CMS RENEWABLE LLC 2100 N HWY 360 #1004, GRAND PRAIRIE, TX 75050, USA PHONE: +14694285563 EMAIL: edgar@cmsrenewable.com LICENSE NO: #35493 ELECTRICAL LICENSE NO: #213982 MODULE DATASHEET PV-11 REV SHEET NAME SHEET SIZE SHEET NUMBER JA M E S G R A V A T T RE S I D E N C E 84 0 E T E X A S S T , GR A P E V I N E , TX 7 6 0 5 1 ANSI B 11" X 17" DATEDESCRIPTION REVISIONS PROJECT NAME & ADDRESS DRAWN BY ESR 03/18/2025INITIAL CMS RENEWABLE LLC 2100 N HWY 360 #1004, GRAND PRAIRIE, TX 75050, USA PHONE: +14694285563 EMAIL: edgar@cmsrenewable.com LICENSE NO: #35493 ELECTRICAL LICENSE NO: #213982 INVERTER DATASHEET PV-12 REV SHEET NAME SHEET SIZE SHEET NUMBER JA M E S G R A V A T T RE S I D E N C E 84 0 E T E X A S S T , GR A P E V I N E , TX 7 6 0 5 1 ANSI B 11" X 17" DATEDESCRIPTION REVISIONS PROJECT NAME & ADDRESS DRAWN BY ESR 03/18/2025INITIAL CMS RENEWABLE LLC 2100 N HWY 360 #1004, GRAND PRAIRIE, TX 75050, USA PHONE: +14694285563 EMAIL: edgar@cmsrenewable.com LICENSE NO: #35493 ELECTRICAL LICENSE NO: #213982 INVERTER CERTIFICATION PV-13 REV SHEET NAME SHEET SIZE SHEET NUMBER JA M E S G R A V A T T RE S I D E N C E 84 0 E T E X A S S T , GR A P E V I N E , TX 7 6 0 5 1 ANSI B 11" X 17" DATEDESCRIPTION REVISIONS PROJECT NAME & ADDRESS DRAWN BY ESR 03/18/2025INITIAL CMS RENEWABLE LLC 2100 N HWY 360 #1004, GRAND PRAIRIE, TX 75050, USA PHONE: +14694285563 EMAIL: edgar@cmsrenewable.com LICENSE NO: #35493 ELECTRICAL LICENSE NO: #213982 OPTIMIZER DATASHEET PV-14 REV SHEET NAME SHEET SIZE SHEET NUMBER JA M E S G R A V A T T RE S I D E N C E 84 0 E T E X A S S T , GR A P E V I N E , TX 7 6 0 5 1 ANSI B 11" X 17" DATEDESCRIPTION REVISIONS PROJECT NAME & ADDRESS DRAWN BY ESR 03/18/2025INITIAL CMS RENEWABLE LLC 2100 N HWY 360 #1004, GRAND PRAIRIE, TX 75050, USA PHONE: +14694285563 EMAIL: edgar@cmsrenewable.com LICENSE NO: #35493 ELECTRICAL LICENSE NO: #213982 DATASHEET PV-15 ATTACHMENT REV SHEET NAME SHEET SIZE SHEET NUMBER JA M E S G R A V A T T RE S I D E N C E 84 0 E T E X A S S T , GR A P E V I N E , TX 7 6 0 5 1 ANSI B 11" X 17" DATEDESCRIPTION REVISIONS PROJECT NAME & ADDRESS DRAWN BY ESR 03/18/2025INITIAL CMS RENEWABLE LLC 2100 N HWY 360 #1004, GRAND PRAIRIE, TX 75050, USA PHONE: +14694285563 EMAIL: edgar@cmsrenewable.com LICENSE NO: #35493 ELECTRICAL LICENSE NO: #213982 DATASHEET PV-16 RACKING REV SHEET NAME SHEET SIZE SHEET NUMBER JA M E S G R A V A T T RE S I D E N C E 84 0 E T E X A S S T , GR A P E V I N E , TX 7 6 0 5 1 ANSI B 11" X 17" DATEDESCRIPTION REVISIONS PROJECT NAME & ADDRESS DRAWN BY ESR 03/18/2025INITIAL CMS RENEWABLE LLC 2100 N HWY 360 #1004, GRAND PRAIRIE, TX 75050, USA PHONE: +14694285563 EMAIL: edgar@cmsrenewable.com LICENSE NO: #35493 ELECTRICAL LICENSE NO: #213982 DATASHEET PV-17 RACKING REV SHEET NAME SHEET SIZE SHEET NUMBER JA M E S G R A V A T T RE S I D E N C E 84 0 E T E X A S S T , GR A P E V I N E , TX 7 6 0 5 1 ANSI B 11" X 17" DATEDESCRIPTION REVISIONS PROJECT NAME & ADDRESS DRAWN BY ESR 03/18/2025INITIAL CMS RENEWABLE LLC 2100 N HWY 360 #1004, GRAND PRAIRIE, TX 75050, USA PHONE: +14694285563 EMAIL: edgar@cmsrenewable.com LICENSE NO: #35493 ELECTRICAL LICENSE NO: #213982 DATASHEET PV-18 RACKING REV SHEET NAME SHEET SIZE SHEET NUMBER JA M E S G R A V A T T RE S I D E N C E 84 0 E T E X A S S T , GR A P E V I N E , TX 7 6 0 5 1 ANSI B 11" X 17" DATEDESCRIPTION REVISIONS PROJECT NAME & ADDRESS DRAWN BY ESR 03/18/2025INITIAL CMS RENEWABLE LLC 2100 N HWY 360 #1004, GRAND PRAIRIE, TX 75050, USA PHONE: +14694285563 EMAIL: edgar@cmsrenewable.com LICENSE NO: #35493 ELECTRICAL LICENSE NO: #213982 JUNCTION BOX DATASHEET PV-19