HomeMy WebLinkAboutCOMA2025-000163 ECEIVED: 2/4/2025 l[ JL 202C
_ 25-000163 "COOK CHILDRENS" DATE OF ISSUANCE' J
GRAPE1 j)E 1625 LANCASTER DRIVE #120
,; , + , CREATING #120 PERMIT #: 25-000163
r BUILDING PERMIT APPLICATION ELECTRONIC REVIEW
� C/O 25-000323
(PLEASE PRINT LEGIBLY - COMPLETE ENTIRE FORM)
JOB ADDRESS: I �- % l�id�t r'cr- t�< SUITE #
LOT: BLOCK: SUBDIVISION:
BUILDING CONTRACTOR (company name): i �L c AL� Z'�' SIG' •� C a r?-, r..(, 11 :11-1 . -Tn 6.
CURRENT MAILING ADDRESS:' C�dfx�r i4i t1i_ ('
CITY/STATE/ZIP:
PROPERTY OWNER: U1("1 Lam, �Iu %,� Cr
CURRENT MAILING ADDRESS:
CITY/STATE/ZIP: , t ,''► C . �` PK
PROJECT VALUE: $ { CiC.)
PH: # -t )7 -q0 -,5171- Fax #
PHONE NUMBER: it, V7
FIRE SPRINKLERED? YES NO
WHAT TRADES WILL BE NEEDED? (Check ones that apply) ELECTRIC PLUMBING MECHANICAL
DESCRIPTION OF WORK TO BE DONE: -T/1 tGf 1 C - k�-e-A C -%CI -r r CREATING #120 FROM EXISTING
! 11,502 SF SHELL BUILDING
USE OF BUILDING OR STRUCTURE: �' ' `� (-- 1 t '' '
NAME OF BUSINESS: COOK CHILDREN'S PHYSICIAN NETWORK
Total Square Footage under roof:
Square Footage of alteration/addition: 611 Y
J I hereby certify that plans have been reviewed and the building will be inspected by a certified energy code inspector in accordance with
State Law. Plan review and inspection documentation shall be made available to the Building Department (required for new buildings,
alterations and additions)
U I hereby certify that plans have been Submitted to the Texas Department of Licensing and Regulation for Accessibility Review.
Control Number: l `C� �`1 Z (Not required for 1 & 2 family dwellings)
0 I hereby certify that an asbestos survey has been conducted for this structure in accordance with the regulatory requirements of the Texas
Department of Health.
(REQUIRED FOR DEMOLITIONS, ADDITIONS AND OR ALTERATION TO COMMERCIAL AND PUBLIC BUILDINGS)
Ln I hereby certify that the foregoing is correct to the best of my knowledge and all work will be performed according to the documents approved by
N
0 the Building Department and in compliance with the City Of Grapevine Ordinance regulating construction. It is understood that the issuance of
this permit does not grant or authorize any violation of any code or ordinance of the City Of Grapevine. I FURTHERMORE UNDERSTAND
L` THAT PLANS AND SPECIFICATIONS ARE NOT REVIEWED FOR HANDICAPPED ACCESSIBILITY BY THE CITY, AND THAT THE
N DESIGN PROFESSIONAL/OWNER IS RESPONSIBLE FOR OBTAINING SUCH APPROVAL FROM THE APPROPRIATE STATE AND
OR FEDERAL AGENCY(S). `
m1 PRINT NAME: ! V .ter, SIGNATURE
w PHONE #: 1 i 7 2�v EMAIL:
Z)
J gCHECK BOX IF PREFERRED TO BE CONTACTED BY E-MAEL
m THE FOLLOWING IS TO BE COMPLETED BY THE BUILDING INSPECTION DEPARTMENT
Construction Type: Approval (/� Permit Valuation: $ � Setbacks A � royal to Issue
p Occupancy Group: 8 Fire Sprinkler: YES NO l Front: Electrical
w Division: Building Depth: Left: Plumbing
F- Zoning: ?0 Building Width: Rear. _ Mechanical
0 Occupancy Load: Grease Trap Right: Hood
Plan Review Approval: Date: y •,-2S Building Permit Fee: _ 6744.50
Z Site Plan Approval: Date: Plan Review Fee: 4,383.93/
w Fire Department: Date: Lot Drainage Fee: %
Public Works Department: Date: Sewer Availability Rate:rr
/
Health Department: Date: Water Availability Rate:
w Approved for Permit: Date: Total Fees: 11,128.43
p Lot Drainage Submitted: Approved: Total Amount Due: 6,744.50
w
PLAN REVIEW INVOICED 1/2 .2025
cc
LL P.O. BOX 95104. GRAPEVINE- TX 78M(817) 410-3165 O:FORA16 y,:;,-,"IRAPPLICATIONSlM24t&.11A1.SM.1107.11109.U11,9J19
City of Grapevine
Building - Commercial
el*,_� _
PO Box 95104
Alteration
Grapevine, Texas 76099
T B b 8
817) 410-3166
Project # 25-000163
Project Description: Interior Renovation (Creating #120 from
Existing 11,502 sf Shell Building, Leaving 4,846 sf) for New
Medical Clinic [C/O 25-000323] [ELECTRONIC REVIEW]
Issued on: 07/25/2025 at 10:09 AM
ADDRESS
INSPECTIONS
5
1625 Lancaster Dr., 120
Grapevine, TX 76051
1. Building Framing 4. Landscaping
2. Building Energy Code 5. Building
Final
LEGAL
3. Final Fire Dept Inspection
Clearview Park Addition
Blk 3 Lot 5
INFORMATION FIELDS
PERMIT HOLDER
—APPLICANT NAME (Individual)
Casey Van Sant
Casey Van Sant
—APPLICANT PHONE NUMBER
817-266-0790
Hutcherson
Construction, Inc.
APPLICANT E-MAIL
(817) 467-5422
""NAME OF BUSINESS Cook Children's Physician Network
VALUATION
998400
COLLABORATORS
• Casey Van Sant
Square Footage
6656
Hutcherson
What is use of Building/Structure?
Medical Clinic
Construction, Inc.
* CONSTRUCTION TYPE
VB
(817)467-5422
* OCCUPANCY GROUP
B
• Reid Hutcherson
APPLICATION. pdf, MECH
Reid Hutcherson
DOCUMENTS - MISC 01
COMcheck.pdf, LIGHTING
(817) 467-5422
COMcheck.pdf
DOCUMENTS - MISC 02
CONSTRUCTION PLANS.pdf
OWNERS
• Evergreen -Fern Ltd
` OCCUPANCY LOAD
82
ZONING DISTRICT
PO
TENANTS
APPROVED TO ISSUE ELECTRIC
YES
• Spencer Seals
Cook Children's
APPROVED TO ISSUE MECHANICAL
YES
Physician Network
APPROVED TO ISSUE PLUMBING
YES
(682) 885-4000
Fire Sprinkler System?
NO
FEE TOTAL
PAID DUE
'Building Permit Fee (Value) $ 6,744.50
$ 6,744.50 $ 6,744.50
Building Permit, Plan Review $ 4,383.93
$ 4,383.93 $ 4,383.93
Page 1/3
MYGOV.US 25-000163, 07/25/2025 at 10:09 AM Issued by: Courtney Cogburn
FEE TOTAL PAID DUE
TOTALS $ 11,128.43 $ 11,128.43 $ 0.00
READ AND SIGN
I HEREBY CERTIFY THAT THE FOREGOING IS CORRECT TO THE BEST OF
MY KNOWLEDGE AND ALL WORK WILL BE PERFORMED ACCORDING TO
THE DOCUMENTS APPROVED BY THE BUILDING DEPARTMENT AND IN
COMPLIANCE WITH THE CITY OF GRAPEVINE ORDINANCE REGULATING
CONSTRUCTION. IT IS UNDERSTOOD THAT THE ISSUANCE OF THIS PERMIT
DOES NOT GRANT OR AUTHORIZE ANY VIOLATION OF ANY CODE OR
ORDINANCE OF THE CITY OF GRAPEVINE.
I FURTHERMORE UNDERSTAND THAT PLANS AND SPECIFICATIONS ARE
NOT REVIEWED FOR HANDICAPPED ACCESSIBILITY BY THE CITY AND THAT
THE DESIGN PROFESSIONAL / OWNER IS RESPONSIBLE FOR OBTAINING
SUCH APPROVAL FROM THE APPROPRIATE STATE AND OR FEDERAL
AGENCY(S).
July 25, 2025
Signature Date
City of Grapevine Building - Commercial Alteration =
G
Project # 25-000163 i r 9 , , I
NOTICES
1) ALL work must be done in compliance with the 2021 INTERNATIONAL BUILDING CODE.
"'ALL work ISSUED prior to January 1, 2024, must be done in compliance with the 2006 INTERNATIONAL
BUILDING CODE.
2) City Approved Stamped Plans must be on -site for ALL INSPECTIONS.
3) Project address must be clearly posted at the job site.
NOTES
> 24 HOUR INSPECTION NUMBER
METRO (817) 410-3010, CUT OFF TIME FOR A.M. INSPECTION IS 7:30 A.M. --- CUT OFF TIME FOR P.M.
INSPECTION IS 12:30 P.M.
> PERMIT ISSUED IN ACCORDANCE WITH APPLICATION ON FILE IN THIS OFFICE.
THIS PERMIT SHALL EXPIRE IF WORK IS NOT COMMENCED WITHIN (180 DAYS) OF ISSUANCE OR IF
WORK IS SUSPENDED OR ABANDONED FOR A PERIOD OF (180 DAYS). THE ISSUANCE OR
GRANTING OF THIS PERMIT AND / OR APPROVAL OF PLANS, SPECIFICATIONS AND
COMPUTATIONS SHALL NOT BE CONSTRUED TO BE A PERMIT FOR, OR AN APPROVAL OF, ANY
VIOLATION OF ANY OF THE PROVISIONS OF THE CODES AND ORDINANCES OF THE CITY OF
Page 2/3
MYGOV.US 25-000163, 07/25/2025 at 10:09 AM Issued by: Courtney Cogburn
W
S
T
A
T
E
H
W
Y
1
1
4
I R A E . W D S A V E
PROJECT SITE
B
A
Y
L
O
R
P
K
W
Y
LANCASTER DR
W H U D G I N S S T
LOCATION MAP
TRUE NORTH
IT/ELEC
BREAKROOM
MA
STATION
WAITING
LAB
RECEPTION
SHARED
OFFICE
RISER
ROOM
N.I.C.
N.I.C.
FOR INFORMATION ONLY
1. PROVIDE SEPARATE LINE ITEM
FOR EXTERIOR DOORS 101 AND
133, RE: DOOR SCHEDULE ON
A511.
2. PROVIDE SEPARATE LINE ITEM
FOR EXTENDED SUPPLY AND
RETURN AIR DUCTS TO NOT IN
CONTRACT SPACES FOR
FUTURE TENANT, RE: MECH
3. PROVIDE SS01 IN LIEU OF
PL134, TYP. RE: FINISH LEGEND
SCHEDULE OF
ALTERNATES
SHEET NUMBER
4040 N CENTRAL EXPY,
SUITE 720
DALLAS, TEXAS 75204
t 314.302.6864
www.modusarchitecture.com
ARCHITECT
OWNER
MODUSARCHITECTURE #
PROJECT TEAM
| |
FOR INFORMATION
PURPOSES ONLY. NOT TO
BE USED IN ANY CAPACITY
FOR BIDDING, PERMITTING,
OR CONSTRUCTION
MEP
REVISIONS:
MODUS ARCHITECTURE, PLLC.
4040 N CENTRAL EXPY, SUITE 720
DALLAS, TEXAS 75204
P: 314.302.6864
SHEET NAME
COOK CHILDREN'S PHYSICIAN NETWORK
801 SEVENTH AVE.
FORT WORTH, TX 76104
P: 682.885.7037
V3 CONSULTING ENGINEERS
12801 N CENTRAL EXPY, SUITE 540
DALLAS, TEXAS 75243
P: 972.643.8814
ISSUE DATE:
TDLR:|
16
2
5
L
A
N
C
A
S
T
E
R
D
R
I
V
E
GR
A
P
E
V
I
N
E
,
T
E
X
A
S
7
6
0
5
1
G000
COVER SHEET
PE
R
M
I
T
S
E
T
COOK CHILDREN'S
PERMIT SET 12/19/2024 240212
1625 LANCASTER DRIVE
GRAPEVINE, TEXAS 76051
CO
O
K
C
H
I
L
D
R
E
N
'
S
12/19/2024
INDEX OF DRAWINGS
SHEET
NO.TITLE ON SHEET
ISSUE
DATE
PERMIT
SET
01 GENERAL
G000 COVER SHEET 12/19/2024 •
G001 GENERAL INFORMATION 12/19/2024 •
G002 ACCESSIBILITY STANDARDS 12/19/2024 •
G003 ACCESSIBILITY STANDARDS 12/19/2024 •
G004 ACCESSIBILITY STANDARDS 12/19/2024 •
G110 OVERALL LIFE SAFETY PLAN 12/19/2024 •
G130 SPECIFICATIONS 12/19/2024 •
G131 SPECIFICATIONS 12/19/2024 •
G132 SPECIFICATIONS 12/19/2024 •
G133 SPECIFICATIONS 12/19/2024 •
G134 SPECIFICATIONS 12/19/2024 •
G135 SPECIFICATIONS 12/19/2024 •
03 ARCH DEMO
AD111 DEMO FLOOR PLAN 12/19/2024 •
04 ARCHITECTURAL
A111 OVERALL FLOOR PLAN 12/19/2024 •
A112 OVERALL POWER PLAN 12/19/2024 •
A113 OVERALL EQUIPMENT PLAN 12/19/2024 •
A121 ENLARGED RESTROOM PLAN & PLAN DETAILS 12/19/2024 •
A511 DOOR SCHEDULE AND DETAILS 12/19/2024 •
A611 REFLECTED CEILING PLAN 12/19/2024 •
A631 CEILING DETAILS 12/19/2024 •
A711 INTERIOR ELEVATIONS 12/19/2024 •
A712 INTERIOR ELEVATIONS 12/19/2024 •
A821 TYPICAL CASEWORK SECTIONS 12/19/2024 •
A822 TYPICAL CASEWORK DETAILS 12/19/2024 •
A901 FINISH LEGEND 12/19/2024 •
A911 FINISH FLOOR PLAN & FINISH DETAILS 12/19/2024 •
05 MECHANICAL
MEP GENERAL NOTES AND SYMBOLS - MEP 12/19/2024 •
M101 FLOOR PLAN - MECHANICAL 12/19/2024 •
M201 SCHEDULES & DETAILS - MECHANICAL 12/19/2024 •
M301 DETAILS - MECHANICAL 12/19/2024 •
06 PLUMBING
P101 FLOOR PLAN - PLUMBING 12/19/2024 •
P201 SCHEDULES & DETAILS - PLUMBING 12/19/2024 •
P202 SCHEDULES & DETAILS - PLUMBING 12/19/2024 •
07 ELECTRICAL
E101 FLOOR PLAN - POWER 12/19/2024 •
E102 FLOOR PLAN - POWER 12/19/2024 •
E201 FLOOR PLAN - LIGHTING 12/19/2024 •
E301 SCHEDULES & DETAILS - ELECTRICAL 12/19/2024 •
TABS2025007242
SYMBOLS:
DRAWING NUMBER
DEMOLITION NOTE NUMBER
FIXTURE ACCESSORY NUMBER
NEW DOOR
DOOR SYMBOLS:
DETAILS:
DOOR NO.
10
1
A
SHEET NUMBER
12
4
24
NOTE TAGS:
SHEET NOTE NUMBER
STRUCTURAL GRID BUBBLE
DRAWING OR DETAIL NUMBER
FIRE EXTINGUISHER & CABINET
DISCPLINE DESIGNATORS:
SYMBOLS:
WALL FINISH TYPE
ROOF DRAIN
OVERFLOW ROOF DRAINORD
RD
ELEVATION MARK
FLOOR DRAIN
FIRE EXTINGUISHER
FEC
FE
FD
RE: 6/ A121
ROOM NAME/NUMBER:
REFERENCE MARK:
NORTH ARROW SYMBOL
BREAK LINE
A
FLOOR LEVEL (2)
SHEET NUMBER
A251B
SHEET NUMBER:
DISCIPLINE
SHEET IN SERIES
AREA (B) IF USED
SUB ROOM NUMBER (06A)
OFFICE
WALL SECTION AND DETAIL SYMBOLS:
BUILDING SECTIONS:
REVISION MARK/ CLOUD:
SHEET NUMBER
1 REVISION NUMBER
SHEET NUMBER
DRAWING NUMBER
DIRECTION
BUILDING SECTION NUMBER
SYMBOLS - WINDOW TYPES/ DOOR & FRAME TYPES/ LOUVER TYPES:
ELEVATION SYMBOLS:
SHEET NUMBER
DRAWING NUMBER
DIRECTION
FIRE HYDRANTFH
MATERIAL KEYNOTE
A711
11
DRAWING NUMBER / SHEET NUMBER
DIRECTION
EXTERIOR
INTERIOR
A3.41
A4
DIRECTION
EXISTING
DOOR
10
1
A
ELECTRICAL
DEMOLITION
CIVIL
ARCHITECTURALA
AD
KC
E
ARCHITECTURAL SITEAS
STRUCTURAL
PLUMBING
MECHANICAL
KITCHEN
P
M
S
TECHNOLOGYT
LANDSCAPEL
BUILDING AREA "B" (IF USED)
ROOM NAME
B-206A
MATCH LINE:
AREA B
AREA A
KEY PLAN SYMBOL:
D A
BC
HATCHED AREA IS
AREA PLAN AS SHOWN
ON SHEET
SERIES
ROOM NUMBER (06)
A2
F1
L2
14
CASEWORK SYMBOLS:
F FURNITURE & EQUIPMENT
GENERALG
BUILDING ADDITION NOTATION:
NEW EXISTING
GLASS TYPES
DOOR FRAME NUMBER SYMBOL
(F1, F2, F3, ETC...)
LOUVER NUMBER SYMBOL
(L1, L2, L3, ...)
WINDOW NUMBER SYMBOL
(A-Z; AA, AB - AZ; BA, BB - BZ...)
11
/
A
7
1
1
A3.21
A3
A3.11
F1
A3.11
F1
22.22G
EL ELECTRICAL - LIGHTING
EP ELECTRICAL - POWER
WALL SYMBOLS:
NEW WALL EXISTING WALL
EXISTING STRUCTURAL GRID BUBBLEA
EXISTING DOOR
TO BE REMOVED
10
1
A
DOOR NO.DOOR NO.
WIDTH
B1CABINET TYPE:
DEPTH
DEMO EXISTING WALL
TRUE PLAN
ELECTRICAL SYMBOLS:
+42"
+42"
DUPLEX RECEPTACLE, 18" AFF TO CENTERLINE OF RECEPTACLE
DUPLEX RECEPTACLE, CENTERLINE OF RECEPTACLE AS NOTED AFF
QUAD RECEPTACLE, CENTERLINE OF RECEPTACLE AS NOTED AFF
QUAD RECEPTACLE, 18" AFF TO CENTERLINE OF RECEPTACLE
PT28
SUSP. CEILING SYSTEM
REFLECTED CEILING PLAN SYMBOLS:
CEILING HEIGHT9'-0"
GYP. BD.
SUPPLY
RETURN
2X4 LIGHT FIXTURE
2X2 LIGHT FIXTURE
DIRECT/INDIRECT
PENDANT FIXTURE
CAN LIGHT
FIRE EXIT SIGN
CONTROL JOINT IN
GYP BD CEILING
2'X2' LAY-IN CEILING
OPEN TO STRUCTURE
EXHAUST
1X4 CONCEALED COVE
LIGHT FIXTURE
FLUORESCENT STRIP FIXTURE
TRACK LIGHTING
SPRINKLER HEAD
SPEAKERS
ABBREVIATIONS:
G
F
H
I
J
K
L
M
N
O
P . CONTINUED...
Q
R
S
T
U
V
W
X,Y,Z, MISCELLANEOUS
F . CONTINUED...
SUSPENDED
CORR CORRIDOR/ CORRUGATED
SUSP
CP
CSMT
CT
CTR
CPT
CS
DEMO
DF
DEPT
DBL
CU.
CW
DN
DISP.
DMT
DIA.
DIAG
DR
DH
EQ
EP
EXH
EWC
ETR
EST
ESC
FB
EXP
EXT
FAB
FA
EXIST
EQUIP
FEC
FF
FE
FD
FBO
FHC
FIN
FH
FF&E
FIXT
EL
ELEV
EMERG
ELAST
ELEC
DWG
EJ
EF
EA
DTL
DS
WINDOWWNDW
&
WR
YD
WH
WP
FINISH/ FINISHED
FIXTURE
FACE BRICK
FIRE HOSE CABINET
FIXTURES / FURNITURE / EQUIPMENT
FURNISHED BY OWNER
FIRE EXTINGUISHER & BRACKET
FIRE HYDRANT
FINISH FLOOR
FIRE EXTINGUISHER CABINET
FLOOR DRAIN
AND
AT
WALL HYDRANT
WATER RESISTANT
WATERPROOFING/ WORKING POINT
YARD
VWC
WC
WD
WB
W/
W
VEST
VERT
VT
TYP
VCT
VB
UNO
UNFIN
TZ
UH
TOW
TRANSF
TV
THRU
TOS
TOD
TOC
TKBD
THK
SWGR
T&G
T&B
TEL
SYS
SYM
S.Y.
DRAWING
NO
OD
OPP
OZ
OPNG
OH
NRC
NTS
NOM
OC
MTD
N/A
MULL
MTL
MTG
NIC
N
MOD
MO
MM
EQUAL
EXPANSION/ EXPANDED
ELECTRIC WATER COOLER
EXISTING TO REMAIN
FIRE ALARM
ESCALATOR
EQUIPMENT
EXHAUST
EXTERIOR
EXISTING
FABRICATE
ESTIMATE
ELEVATOR
EMERGENCY
ELECTRICAL PANELBOARD
ELASTOMERIC
EXPANSION JOINT
EXHAUST FAN
ELECTRICAL
ELEVATION
EACH
EAST
ON CENTER
OUTSIDE DIAMETER
NOT TO SCALE
NOISE REDUCTION COEFFICIENT
OPPOSITE
OUNCE
OPENING
OVERHEAD/ OPPOSITE HAND
NOMINAL
NOT IN CONTRACT
METAL
MASONRY OPENING
MOUNTING
NUMBER
NOT APPLICABLE
NORTH
MULLION
MOUNTED
MODULAR
MILLIMETER
LVR
MISC
MFR
MFG
MEMB
MED
MECH
MIN
MH
MBR
MAX
MAS
LWC
M
LH
LT(G)
LPT
LLV
LLH
LF
LBS
DOWNSPOUT
DISPENSER
DEMOUNTABLE
DIAMETER
DOUBLE HUNG
DETAIL
DOOR
DOWN
DIAGONAL
DEMOLISH/ DEMOLITION
DRINKING FOUNTAIN
DEPARTMENT
CASEMENT
CUBIC
COLD WATER
CERAMIC TILE
COUNTERSINK
CONCRETE PIPE
COUNTER
DOUBLE
CARPET
METER (S)
MISCELLANEOUS
MANUFACTURER
MECHANICAL
MEMBRANE
MANHOLE
MINIMUM
MANUFACTURING
MEMBER
MAXIMUM
MASONRY
MEDIUM
LIGHTWEIGHT CONCRETE
LONG LEG VERTICAL
LONG LEG HORIZONTAL
LINEAR FOOT (FEET)
LOUVER
LOW POINT
LIGHT/ LIGHTING
LEFT HAND
POUNDS
T
WEST, WIDTH, WIDE, WATER
WATER CLOSET
VINYL WALLCOVERING
WOOD
WOOD BASE
WITH
VERTICAL
VINYL TILE
VESTIBULE
VINYL COMPOSITION TILE
VAPOR BARRIER (VPR.BR.)
UNLESS NOTED OTHERWISE
UNFINISHED
UNIT HEATER
TRANSFORMER
TOP OF STEEL
TOP OF CURB/ CONCRETE
TERRAZZO
TYPICAL
TELEVISION
TOP OF WALL
TOP OF DECK
THROUGH
TONGUE & GROOVE
TOP & BOTTOM
SQUARE YARD (SQ.YD.)
TACK BOARD
THICK (NESS)
TELEPHONE
TREAD
SYSTEM
SWITCH GEAR
SYMMETRICAL
BOC
BD
BM
BLDG
BLKG
BLK
BTWN
BIT
CAB
BRG
BVL
BSMT
BRK
BW
CMU
CCTV
CAP
CB
BO
CFM
CIP
CG
CF
CJ
CLR
CLOS
CM
CLG
CL
CMT
COMB
COL
CO
CMP
CONST
COORD
CONTR
CONT
CONN
CONC
RETURN AIRRA
SUBFLR
STRUCT
STOR
STL
STG
STC
STD
SPEC
SOG
SP.HD.
SPKR
SOF
SECT
SCH
SHT
SHM
SCN
SAN
RTU
REQMT
REQD
REINF
HEATING
CLOSED CIRCUIT TV
HTG
LAB
LAV
LAM
KIT
INST
INCAND
INV
INT
INSUL
INFO
INCL
HW
HWH
HVAC
IN
ID
HTR
CENTIMETER
CONSTRUCT/ CONSTRUCTION
CONTINUOUS
COORDINATE
CONTRACTOR
CERAMIC MOSAIC TILE
CORRUGATED METAL PIPE
CONNECTION
COMBINATION
CLEAN OUT
CONCRETE
COLUMN
CONTROL JOINT
CLEAR/ CLEARANCE
CENTER LINE
CUBIC FEET PER MINUTE
CAST-IN-PLACE
CORNER GUARD
CUBIC FEET
CAST IRON
CEILING
CLOSET
INTERIOR
INCANDESCENT
LABORATORY
LAMINATE (D)
LAVATORY
KITCHEN
INVERT SS
SQ
INSTALL/ INSTALLATION
INSULATE/ INSULATION
INFORMATION
INCLUDE (D), (ING)
AIR CONDITIONING
HOT WATER HEATER
INSIDE DIAMETER
HEATING/ VENTILATING/
INCH
HOT WATER
HEATER
SIM
SF
SC
HM
HT
HR
HS
HPT
HORIZ
GYP
HC
HK
HDW
HDR
HD
HDBD
HB
GOVT
GPM
GL
GFRC
BENCH MARK/ BEAM
CONCRETE MASONRY UNIT (S)
CATCH BASIN
BOTH WAYS
BASEMENT
CABINET
CAPACITY
BEARING
BEVELED
BRICK
BOTTOM OF
BACK OF CURB
BITUMINOUS
ACOUSTICAL WALL PANEL
AUTOMATIC
ATTENUATION
BOARD
BUILDING
BLOCKING
BLOCK
BETWEEN
ATTEN
AUTO
AWP
AVG AVERAGE
GYPSUM
HOLLOW CORE
HOLLOW METAL
HEAD
HIGH STRENGTH
HIGH POINT
HOOK
HEIGHT
HOUR
HORIZONTAL
HARDWARE
HEADER
HARDBOARD
HOSE BIBB
RM
RO
S
RFG
RH
REV
GALLON PER MINUTE
GOVERNMENT
GLASS/ GLAZING
GLASS FIBER REINF. CONC.
REC (D)
REF
RCP
RE:
RD
RB
SOUTH
SPEAKER
STRUCTURE/ STRUCTURAL
SOUND TRANSM. COEFFICIENT
STAINLESS STEEL
SEATING
SUBFLOOR
STORAGE
STEEL
STANDARD
SQUARE
SPRINKLER HEAD
SLAB ON GRADE
SPRAY-ON FIREPROOFING
SECURITY HOLLOW METAL
SANITARY SEWER
SPECIFICATION (S)
SIMILAR
SHEET
SCHEDULE
SQUARE FOOT (SQ.FT.)
SECTION
SCREEN
SOLID CORE
ROUGH OPENING
ROOF TOP UNIT
RIGHT HAND
REVISED/ REVISION
ROOM
ROOFING
REINFORCE (D), (ING)
REFRIGERATOR
REFLECTED CEILING PLAN
RECEIVE (D)
REQUIRED
REQUIREMENT
REFERENCE/ REFER TO
ROOF DRAIN
RESILIENT BASE
PVMT
PROJ
PRELIM
PREP
FURR
FDV
GALV
FUT
GC
GA
FTG
FT
FR(FRM)
FDN
FOS
ADD ADDENDUM
ALUMINUM
ARCH PRECAST CONCRETE
ARCHITECT/ ARCHITECTURAL
APPROXIMATE
ACCESS PANEL
ALTERNATE
ANODIZED
AIR HANDLING UNIT
ABOVE FINISH FLOOR
ADJUSTABLE/ ADJACENT
ANOD
APPROX
ARCH
APC
AP
ALUM
ALT
AHU
AFF
ADJ
ACOUSTICAL CEILING TILE
ACOUSTICAL
AREA DRAIN
ACOUSTICAL CEILING PANEL
AIR CONDITIONING
ACOUST
ACT
AD
A/ C
ACP
GENERAL CONTRACTOR
FIRE DEPARTMENT VALVE
GALVANIZED
GAUGE
FOOT/ FEET
FUTURE
FURRING
FOOTING
R
QTY
PVC
PTD
PT
PSI
FRAME (D), (ING)
FACE OF STUDS
FOUNDATION
PSF
POLYVINYL CHLORIDE
POUNDS PER SQUARE INCH
PAVEMENT
QUANTITY
RISER/ RADIUS/ REVERSED
PAINTED
POINT
POUNDS PER SQUARE FOOT
PROJECT
PRELIMINARY
PREPARE (D)
JST
JT
JC
JAN
JB
JANITOR CLOSET
JOIST
JOINT
JUNCTION BOX
JANITOR
A
B
C
D
E
CI
A/ V AUDIO/ VISUAL
BRKT BRACKET
DIM DIMENSION
E
FS
FVC FIRE VALVE CABINET
FLOOR SINK
HDWD HARDWOOD
KP KICK PLATE
L LONG/ LENGTH
LRG LARGE
ORD OVERFLOW ROOF DRAIN
TOP TOP OF PARAPET
TEMP TEMPORARY/ TEMPERED
W/IN WITHIN
W/O WITHOUT
WT WEIGHT
FLUOR
FLR
FLG
FLUORESCENT
FLASHING
FLOOR
FOG
FOF
FOC FACE OF CONCRETE
FACE OF GYPSUM BOARD/ WALL
FACE OF FINISH
P
PANEL BOARDPB
PERP
POLY
PLUMB
PNL
PREFIN
PLAS
PLAM
PL
PERM
PERF
PREFAB
PC
PLASTER
PERPENDICULAR
POLYETHYLENE
PLUMBING
PANEL
PLATE/ PROPERTY LINE
PERFORATE (D)
PERMANENT
PLASTIC LAMINATE
PREFINISHED
PREFABRICATE (D)
PRECAST CONCRETE
PA PUBLIC ADDRESS
PLYWD PLYWOOD
R/W RIGHT OF WAY
GB GRAB BAR
TRANSM TRANSMISSION
@
VTR VENT THROUGH ROOF
FOM FACE OF MASONRY
FFE FINISH FLOOR ELEVATION
C COURSE
BOT BOTTOM
TOM TOP OF MASONRY
OTS OPEN TO STRUCTURE
1. ALL CONTRACTORS AND THEIR SUPERVISORY PERSONNEL SHALL REVIEW THE GENERAL
AND SUPPLEMENTARY CONDITIONS TO THE CONTRACT.
2. ALL WORK SHALL CONFORM WITH APPLICABLE BUILDING CODES, REGULATIONS AND
ORDINANCES.
3. CONTRACTOR SHALL OBTAIN ALL REQUIRED BUILDING AND OCCUPANCY PERMITS.
4. CONTRACTOR SHALL BECOME FULLY ACQUAINTED WITH CONDITIONS RELATED TO THE
WORK.
5. CONTRACTOR SHALL BE SOLELY RESPONSIBLE FOR THE MEANS, METHODS, AND
SEQUENCES OF CONSTRUCTION AND THE SAFETY OF ALL CONSTRUCTION PERSONNEL AND
VISITORS.
6. DRAWINGS CONTAINED IN THIS SET SHALL NOT BE REPRODUCED FOR SHOP DRAWINGS.
COPIES OF THESE DRAWINGS SUBMITTED AS SHOP DRAWINGS WILL BE REJECTED AND
RETURNED TO THE CONTRACTOR.
7. EACH INSTALLER MUST EXAMINE SUBSTRATE AND/OR CONDITIONS UNDER WHICH THE WORK
WILL BE INSTALLED AND REPORT TO THE CONTRACTOR IN WRITING ANY CONDITIONS
DETRIMENTAL TO THE PROPER AND TIMELY EXECUTION OF THAT INSTALLERS WORK. DO NOT
PROCEED UNTIL UNSATISFACTORY CONDITIONS ARE CORRECTED. COMMENCING WITH
INSTALLATION SHALL CONSTITUTE ACCEPTANCE OF THE SUBSTRATE AND/OR CONDITIONS.
8. DO NOT SCALE DRAWINGS: FOLLOW WRITTEN DIMENSIONS AND NOTES. CONTACT
ARCHITECT FOR CLARIFICATIONS, IF REQUIRED.
9. DIMENSIONS SHOWN ON THE FLOOR PLAN ARE TO THE FACE OF GYP. BOARD/ WALL (FOG),
FACE OF MASONRY (FOM), FACE OF CONCRETE WALLS (FOC), AND COLUMN GRID LINES,
UNLESS OTHERWISE NOTED OR INDICATED.
10. "TYPICAL", AS USED IN THESE DOCUMENTS, SHALL MEAN THAT THE CONDITION OR
DIMENSION IS REPRESENTATIVE OF, OR THE SAME, FOR SIMILAR CONDITIONS THROUGHOUT.
11. IF THERE IS A DISCREPANCY BETWEEN SMALL SCALE AND LARGE SCALE DRAWINGS, (PLAN,
SECTION, & DETAIL DRAWINGS, ETC.) - CONTACT ARCHITECT FOR CLARIFICATION. FOR
BIDDING PURPOSES: THE MOST EXPENSIVE AND/OR STRICTEST REQUIREMENTS SHALL
GOVERN. FOR CLARIFICATIONS DURING CONSTRUCTION: THE MOST EXPENSIVE AND/OR
STRICTEST REQUIREMENTS, AS INDICATED BY THE ARCHITECT, SHALL GOVERN.
12. ANY DISCREPANCIES BETWEEN THE DRAWINGS AND SPECIFICATIONS - CONTACT ARCHITECT
FOR CLARIFICATION. FOR BIDDING PURPOSES: THE MOST EXPENSIVE AND/OR STRICTEST
REQUIREMENTS SHALL GOVERN. FOR CLARIFICATIONS DURING CONSTRUCTION: THE MOST
EXPENSIVE AND/OR STRICTEST REQUIREMENTS, AS INDICATED BY THE ARCHITECT, SHALL
GOVERN.
13. ANY DISCREPANCIES BETWEEN THE DRAWINGS AND ACTUAL CONDITIONS SHALL BE
REPORTED TO THE ARCHITECT IN WRITING FOR RESOLUTION, PRIOR TO PROCEEDING WITH
THE WORK.
14. ANY AND ALL DISCREPANCIES SHALL BE REPORTED TO THE ARCHITECT IN WRITING FOR
RESOLUTION, PRIOR TO PROCEEDING WITH THE WORK. IN THESE INSTANCES: NO CHANGE
ORDERS OR EXTENSIONS OF TIME WILL BE ALLOWED OR ACCEPTED FOR PROCEEDING WITH
THE WORK WITHOUT THE ARCHITECT’S WRITTEN DIRECTION AND APPROVAL. ALSO -
CONTRACTOR MUST REPAIR AND/OR REPLACE ANY UNAUTHORIZED WORK, AS INDICATED BY
THE ARCHITECT, AT NO ADDITIONAL COST TO THE OWNER.
15. ALL DISSIMILAR METAL MATERIALS SHALL BE ISOLATED WITH AN APPROVED NONMETAL
ISOLATION MATERIAL.
16. OPEN EXTERIOR JOINTS AROUND WINDOW AND DOOR FRAMES, BETWEEN WALLS AND
FOUNDATIONS, BETWEEN WALL PANELS, AND AT PENETRATIONS OF UTILITIES THROUGH THE
BUILDING ENVELOPE, ETC. – SHALL BE SEALED, CAULKED, FLASHED OR WEATHER-STRIPPED
AS REQUIRED FOR COMPATIBILITY WITH ADJACENT MATERIALS & TO ELIMINATE AIR LEAKAGE
AND WATER ENTRY.
17. PROVIDE SEALANT AND/OR CAULKING BETWEEN DISSIMILAR ADJOINING INTERIOR
MATERIALS. (I.E. WINDOW SILLS TO GYP. BD., ACT CEILINGS TO MASONRY WALLS, ETC.)
18. DOOR OPENINGS NOT LOCATED BY DIMENSION SHALL BE CENTERED IN WALL SHOWN OR
LOCATED 2 INCHES FROM FINISH WALL TO FINISH JAMB, ALWAYS ALLOWING A MINIMUM OF
18" FROM THE PULL SIDE OF THE DOOR TO THE INTERSECTING WALL.
19. CONTRACTOR SHALL VERIFY THE LOCATIONS OF ALL EXISTING UNDERGROUND UTILITIES
AND THEIR SERVICE CONNECTIONS WITH THE PROPER UTILITY COMPANY.
20. CONTRACTOR SHALL COORDINATE SIZE, LOCATIONS AND NUMBER OF ALL ROOF OPENINGS
AND ROOF ACCESSORIES WITH ALL OTHER TRADES. REFER TO THE ARCHITECTURAL,
STRUCTURAL, PLUMBING, MECHANICAL AND ELECTRICAL DRAWINGS.
21. EXCEPT AT FIRE-RATED PARTITIONS, ALL WALL AND COLUMN GYPSUM BOARD FACING SHALL
BE HELD AT 5/8 INCH BELOW STRUCTURE, UNLESS DETAILED OR NOTED OTHERWISE.
22. AT ALL TELECOMMUNICATION ROOMS: PROVIDE 3/4" X 8'-0" HIGH FIRE-RETARDANT-TREATED
WOOD SHEATHING OR PROVIDE PLYWOOD OVER NON-COMBUSTIBLE SHEATHING; BOTTOM
TO BE LOCATED AT 4" A.F.F. VERIFY LENGTHS AND LOCATIONS WITH ELECTRICAL DRAWINGS.
23. GLASS DOORS, ADJACENT PANELS AND ALL GLAZED OPENINGS WITHIN 1'-6" OF THE FLOOR,
AND WITHIN A 24-INCH ARC OF EITHER VERTICAL EDGE OF A DOOR, ETC., SHALL BE SAFETY
GLAZING AS APPROVED FOR IMPACT BY APPLICABLE BUILDING CODES, AND SHALL BE
LABELED AS SUCH.
24. ALL CEILING HEIGHTS AS SHOWN ON PLANS AND DETAILS ARE FROM SLAB OR TILE FLOOR
(FINISHED FLOOR) TO FINISH CEILING.
25. PROVIDE INDEPENDENT FRAMING & ATTACHMENTS TO THE STRUCTURE – ADEQUATE TO
SUPPORT THE CEILING SYSTEM, LIGHT FIXTURES, DUCTS, DIFFUSERS, SPRINKLER PIPING
AND BUS DUCTS.
26. ALL CLOSETS AND ALCOVES WITHOUT A SPACE IDENTIFICATION NUMBER SHALL HAVE THE
SAME FINISHES AS ADJOINING SPACES.
27. CONTRACTOR TO INSTALL FR WOOD BLOCKING AND FR PLYWOOD AS REQUIRED FOR THE
MOUNTING OF ALL TOILET ACCESSORIES, MILLWORK/ CASEWORK, AV EQUIPMENT, MEP
ITEMS, AND RADIOLOGY EQUIPMENT, OWNER MOUNTED EQUIPMENT, ETC. COORD WITH
OWNER FOR FINAL EQUIPMENT LOCATIONS.
28. RE: SPECIFICATIONS FOR ALL REQUIRED TESTING AND INSPECTIONS.
29. ANY/ ALL PROPRIETARY PRODUCTS DESCRIBED AND/OR DRAWN IN THE DOCUMENTS (BUT
NOT SPECIFIED) ARE TO MEET THE MANUFACTURER’S STANDARD CRITERIA WHICH IS NOT
LIMITED TO THE FOLLOWING: PERFORMANCE REQUIREMENTS, QUALITY ASSURANCE
REQUIREMENTS, APPLICABLE CODES AND INDUSTRY STANDARDS, FABRICATION, ASSEMBLY,
HANDLING, DELIVERY, STORAGE, INSTALLATION, OPERATION, ADJUSTMENTS, ETC. PROVIDE
THE MANUFACTURER’S STANDARD WARRANTY AND STANDARD FINISH WARRANTY. PROVIDE
PRODUCT DATA, SHOP DRAWINGS, SAMPLES, AND MAINTENANCE DATA AS REQUIRED. REFER
TO DIVISION 01 SPEC. SECTIONS WHICH ALSO APPLY - SUCH AS SUBSTITUTION PROCEDURES,
SUBMITTAL PROCEDURES, QUALITY REQUIREMENTS, REFERENCES, EXECUTION, AND
CLOSEOUT PROCEDURES. NOTE: ANY SUBSTITUTIONS MUST MEET THE DESIGN INTENT, AS
WELL AS THE CRITERIA DESCRIBED ABOVE.
30. COORD. W/ OWNER FOR FINAL LOCATION & BLOCKING REQUIREMENTS FOR ALL WALL
MOUNTED EQUIPMENT.
31. TENANT FURNISHED EQUIPMENT IS NIC BUT IS SHOWN AS DASHED FOR CLARITY, GENERAL
CONTRACTOR SHALL COORDINATE WITH ALL DISCIPLINES INVOLVED WITH SURROUNDING
CLEARANCES, UTILITY ROUGHIN, AND CONSTRUCTION.
32. ALL EXTERIOR WALLS SHALL HAVE 6" OF BATT INSULATION FOR FULL HEIGHT OF WALL. GC
TO VERIFY EXISTING CONDITIONS AND PROVIDE INSULATION. AS REQ.
33. ALL EXTERIOR WALLS SHALL BE FINISHED WITH PAINTED GYP. BD. TO 6" ABOVE FINISH
CEILING.
34. ALL INTERIOR FINISHES TO BE CLASS A FLAME SPREAD PER IBC REQUIREMENTS IN SECTION
803.
DOCUMENTS FOR DELEGATED DESIGN SUBMITTAL ITEMS SHALL BE SUBMITTED BY THE GENERAL
CONTRACTOR TO THE REGISTERED DESIGN PROFESSIONAL IN RESPONSIBLE CHARGE WHO SHALL
REVIEW THEM AND FORWARD TO THE BUILDING OFFICIAL WITH A NOTATION INDICATING THE
DEFERRED SUBMITTAL DOCUMENTS HAVE BEEN REVIEWED AND FOUND TO BE IN GENERAL
CONFORMANCE WITH THE DESIGN OF THE BUILDING. THIS LIST IS PROVIDED TO ASSIST WITH
DELEGATED DESIGN SUBMITTALS. THE FOLLOWING ITEMS ARE REQUESTED AS DELEGATED DESIGN
SUBMITTALS AS THEY ARE SPECIFIED IN THE PROJECT MANUAL AS DELEGATED-DESIGN ITEMS:
1. COLD-FORMED METAL FRAMING SYSTEM
2. AUTOMATIC FIRE SUPPRESSION SYSTEM
3. FIRE ALARM & DETECTION SYSTEMS
4. SIGNAGE / EXTERIOR GRAPHICS
5. METAL FABRICATIONS
DELEGATED DESIGN SUBMITTAL
GENERAL INFORMATION NOTES
SHEET NUMBER
4040 N CENTRAL EXPY,
SUITE 720
DALLAS, TEXAS 75204
t 314.302.6864
www.modusarchitecture.com
FOR INFORMATION
PURPOSES ONLY. NOT TO
BE USED IN ANY CAPACITY
FOR BIDDING, PERMITTING,
OR CONSTRUCTION
REVISIONS:
SHEET NAME
ISSUE DATE:
16
2
5
L
A
N
C
A
S
T
E
R
D
R
I
V
E
GR
A
P
E
V
I
N
E
,
T
E
X
A
S
7
6
0
5
1
G001
GENERAL
INFORMATION
PE
R
M
I
T
S
E
T
CO
O
K
C
H
I
L
D
R
E
N
'
S
12/19/2024
402.2 Components
Accessible routes shall consist of one or more of the following components: walking surfaces with a
running slope not steeper than 1:20. doorways, ramps, curb ramps excluding the flared sides. elevators,
and platform lifts.
403.3 Slope
Running slope shall not exceed 1:20. If slope exceeds 1:20, refer to 'ramps' or 'curb ramps' sections.
Cross slope shall not exceed 1:48.
403.4 Changes in Level
• Up to 1/4": requires no edge treatment (vertical edge permitted).
• 1/4" to 1/2": Edge shall be beveled with a slope no greater than 1:2.
• Greater than 1/2": Requires curb ramp, ramp, elevator, or platform lift.
• Stairs shall not be part of an accessible route.
403.5.1 Width
Minimum clear width of walking surfaces shall be 36" (except as allowed at doors).
403.5.2 Clear Width at Turns
Where the accessible route makes a 180 degree turn around an element which is less than 48" wide,
clear width shall be 42" minimum approached the turn, 48" minimum at the turn and 42" minimum
leaving the turn.
403.5.3 Passing Space
An accessible route with a clear width less than 60" shall provide passing spaces at intervals of 200'
maximum. Passing spaces shall be either: a space 60" minimum; or, an intersection of two walking
surfaces providing a t-shaped space complying with turning space requirements, where the base and
arms of the "T" extend 48" minimum beyond the intersection.
307.4 Vertical Clearance
Vertical clearance shall be 80" high minimum. Guardrails or other barriers shall be provided where the
vertical clearance is less than 80" high. The leading edge of such guardrail or barrier shall be located
27" maximum above the finish floor or ground.
705.1 Detectable Warnings (Required within Public Right-of-Way & Platform Edge)
At Hazardous Vehicular Areas. If a walk within an accessible route crosses or adjoins a vehicular way,
and the walking surfaces are not separated by curbs, railings, or other elements between the
pedestrian areas and vehicular areas, the boundary between the areas shall be defined by a
continuous detectable warning 24" wide, complying the requirements below.
Detectable Warnings: Surface shall consist of raised truncated domes with the following features:
• Diameter: 0.9" nominal,
• Height: 0.2" nominal,
• Surface: Shall visually contrast with adjoining surfaces.
302.2 Carpet
Carpet or carpet tile shall:
• Be securely attached;
• Have a firm cushion, pad, or backing (or none);
• Have a level loop, textured loop, level cut pile, or level cut/uncut pile texture;
• Have a maximum pile thickness of 1/2";
• Have exposed edges fastened with edge trim the entire length of exposed edge.
302.3 Opening (Gratings)
Opening in floor or ground surfaces shall allow passage of sphere more than 1/2" diameter.
Elongated openings shall be placed so that the long dimension is perpendicular to the dominate
direction of travel.
204.3 Turning Space
• The circular turning space shall be a space of 60" diameter minimum. The space shall be
permitted to include knee and toe clearance.
• The T-shaped turning space shall be T-shaped space within a 60" square minimum with arms and
base 36" wide minimum. Each arm shall be clear of obstructions 12" minimum in each direction
and the base shall be clear of obstruction 24" minimum.
305 Clear Floor Space
The clear floor or ground space shall be 30" by 48", and may be positioned for either a forward or parallel
approach.
• If a forward approach clear floor space extends more than 24" into an alcove, the minimum alcove
width shall be 36".
• If a parallel approached clear floor space extends more than 15" into an alcove, the minimum alcove
length shall be 60".
306 Knee and Toe Clearance
Where space beneath an element is included as part of clear floor or ground space or turning space, the
space shall comply with required knee and toe clearance. Additional space shall not be prohibited
beneath an element but shall not be considered as part of the clear floor or ground space or turning
space.
306.2 Toe Clearance
• Space under an element between the finish floor and 9" above the finished floor shall be considered
toe clearance.
• Toe clearance shall extend 25" maximum under an element.
• Where toe clearance is required at an element as part of a clear floor space, the tow clearance shall
extend 17" minimum under the element.
• Space extending greater than 6" beyond the available knee clearance at 9: above the finish floor shall
not be considered toe clearance.
• Toe clearance shall be 30" wide minimum.
206.3 Knee Clearance
• Space under an element between 9" and 27" above the finish shall be considered knee clearance.
• Knee clearance shall extend 25" maximum under an element at 9" above the finish floor.
• Where knee clearance is required under an element as part of a clear floor space, the knee clearance
shall be 11" deep minimum at 9" above the finish floor, and 8" deep minimum at 27" above the finish
floor.
• Between 9" and 27" above the finish floor, the knee clearance shall be permitted to reduce at a rate of
1" in depth for each 6" in height.
• Knee clearance shall be 30" wide minimum.
307 Protruding Object
• Objects projecting from walls with their leading edges between 27" and 80" above the finished floor
shall protrude no more than 4" into walks or corridors.
• Objects projecting from walls with their leading edge at or below 27" above the finished floor may
protrude any amount.
• Free-standing objects mounted on posts or pylons shall overhang 12" maximum when located 27" to
80" above the finished floor or ground.
• Protruding objects shall not reduce the required clear width of an accessible route or maneuvering
space.
308 Reach Ranges
• where a forward reach is unobstructed, the high forward reach shall be 48" maximum and the low
forward reach shall be 15" minimum above finish floor or ground.
• Where a high forward reach is over an obstruction, the clear floor space shall extend beneath the
element for a distance not less than the required reach depth over the obstruction. The high forward
reach shall be 48" maximum where the reach depth is 20" maximum. Where the reach depth exceeds
20", the high forward reach shall be 44" maximum and the reach depth shall be 25" maximum.
• Where a parallel approach is unobstructed, the high side reach shall be 48
maximum and the low side reach shall be 15" minimum above finish floor.
• Where a high side reach is over an obstruction, the height of the obstruction shall be 34" maximum and
the depth of the obstruction shall be 24" maximum. The high side reach be 48" maximum for a reach
depth up to 10", and 46" for a reach depth 10"-24" above the finish floor.
309 Operable Parts
All controls and operating mechanisms is accessible spaces, along accessible routes, and as parts of
accessible elements, shall comply with th following:
• Clear floor space shall be provided to allow forward or parallel approach.
• Heights of all operable portions shall comply with the reach ranges. Electrical and communications
system receptacles on walls shall be 15" minimum above the floor.
• Controls and operating mechanisms shall be operable with one hand and shall not require tight
grasping, pinching, or twisting of the wrist. The force required to activate controls shall be no greater
than 5 pounds maximum.
404.1 General
Doors, doorways, and gates that are part of an accessible route shall comply with this section.
404.2.1 Revolving Doors, Gates, and Turnstiles
Revolving doors, revolving gates, and turnstiles shall not be part of an accessible route.
404.2.2 Double-leaf Doors and Gates
At least one of the active leaves of the doorway with two leaves shall comply with this section.
404.2.3 Clear Width
Door openings shall provide a clear opening of 32" minimum. Clear openings of doorways with
swinging doors shall be measured between the face of the door and stop, with the door open
90 degrees. Openings more than 24" deep shall provide a clear opening of 36" minimum. There
shall be no projections into the clear required clear opening width lower than 34" above the
finish floor or ground. Projections into the clear opening width between 34" and 80" above finish
floor or ground shall not exceed 4".
Exception: Door closers and door stops shall be permitted to be 78" minimum above the
finish floor or ground.
404.2.4 Maneuvering Clearances
• Maneuvering clearances shall extend the full width of the door way and the required latch
side or hinge side clearance, as shown in figures 404.2.4.1 and 404.2.4.2.
• Maneuvering clearances, in addition to doorway width, are required at recessed doors and
gates (all dimensions are minimum), as shown in figure 404.2.4.3.
404.2.5 Thresholds
Thresholds, if provided at doorways, shall be 1/2 inch high maximum.
404.2.6 Doors in Series and Gates in Series
The distance between two hinged or pivoted doors in series and gates in series shall be 48"
minimum plus the width of doors or gates swinging into the space.
404.2.7 Door and Gate Hardware
Handles, pulls, latches, locks, and other operable parts on doors and gates shall have a shape
that is easy to grasp with one hand and does not require tight grasping, tight pinching, or
twisting of the wrist to operate.
• Level-operated mechanisms, pull-type mechanisms, and U-shaped handles are acceptable
designs.
• Operable parts of such hardware shall be 34" minimum and 48" maximum above the finish
floor or ground.
• Where sliding door are in the fully open position, operating hardware shall be exposed and
usable from both sides.
• The forces required to activate operable parts shall be 5 pounds maximum.
404.2.8.1 Door Closers and Gate Closers
Door closers and gate closers shall be adjusted so that from an open position of 90 degrees,
the time required to move the door to a position of 12 degrees from the latch is 5 seconds
minimum.
404.3.9 Door and Gate Opening Forces
Fire doors shall have a minimum opening force allowable by the appropriate administrative
authority. The force for pushing or pulling open a door or gate other than fire doors shall be as
follows:
1. Interior hinged doors and gates: 5 pound maximum.
2. Sliding or folding doors: 5 pounds maximum.
These forces do not apply to the force required to retract latch bolts or disengage other devices
that hold the door in a closed position.
404.2.11 Vision Lights
Doors, gates, and side lights adjacent to doors or gates, containing one or more glazing panels
that permit viewing through the panels shall have the bottom of at least one glazed panel
located 43" maximum above the finish floor.
Exception: Vision lights with the lowest part more than 66" from the finish floor or ground
shall not be required to comply with 404.2.11.
404.3 Automatic Doors and Power-Assisted Doors and Gates
Full-powered automatic doors shall comply with ANSI/BHMA A156.10-1999.
Lowe-energy and power-assisted doors shall comply with ANSI A156.19 (1997 or 2002
edition).
Doorways shall provide a clear opening of 32" minimum in power-on and power-off mode. The
minimum clear width for automatic door systems in a doorway shall be based on the clear
opening provided by all leaves in the open position.
402: ACCESSIBLE ROUTE
404: DOORS, DOORWAYS, & GATES
1/
4
"
M
A
X
1/
4
"
-
1
/
2
"
Changes in Level
2
1
T-Shaped Turning Space
Figure 304.3.2
Clear Floor or Ground Space
Figure 305.5
Toe & Knee Clearance
Figure 306.2 & 306.3
18" min.
60
"
m
i
n
48
"
m
i
n
48
"
m
i
n
12" min
36" min 60
"
m
i
n
42" min 54
"
m
i
n
24" min
48
"
m
i
n
48
"
m
i
n
22" min
48
"
m
i
n
22" min
42
"
m
i
n
24" min
48
"
m
i
n
24" min
24" min
54
"
m
i
n
48
"
m
i
n
42
"
m
i
n
42
"
m
i
n
22" min
42
"
m
i
n
24" min
18" min
x
>
8
"
60
"
m
i
n
12" min
48
"
m
i
n
x
>
8
"
48
"
m
i
n
x
>
8
"
Maneuvering Clearances at
Recessed Doors &Gates
Figure 404.2.4.3
(b)
push side
(a)
push side
(c)
push side, door provided
with both closer and latch
(a)
front approach
(b)
side approach
(c)
pocket or hinge approach
(d)
stop or latch approach
Maneuvering Clearances at Doorways without
Doors, Sliding Doors, Gates, & Folding Doors
Figure 404.2.4.2
Maneuvering Clearances at
Manual Swing Doors & Gates
Figure 404.2.4.1
(k)
latch approach,push side,
door provided with closer
(i)
latch approach,pull side,
door provided with closer
(h)
latch approach,pull side
(g)
hinge approach, push side, door provided
with both closer and latch
(f)
hinge approach, push side
(e)
hinge approach, pull side
(c)
front approach, push side, door
provided with both closer and latch
(d)
hinge approach, pull side
(b)
front approach, push side
(a)
front approach, pull side
(j)
latch approach,push side
27
"
m
a
x
clear width amount
any
STAIRS
80
"
m
i
n
4" max
27
"
m
i
n
>20" up to 25" max
44
"
m
a
x
20" max
48
"
m
a
x
48
"
m
a
x
15
"
m
i
n
10" max
15
"
m
i
n
48
"
m
a
x
10" max
34
"
m
a
x
48
"
m
a
x
> 10" up to 24" max
34
"
m
a
x
48
"
m
a
x
9"
m
i
n
27
"
m
i
n
8" min
11" min
9"
.
6" max
Unobstructed Side Reach
Figure 308.3.1
Unobstructed High Side Reach
Figure 308.3.2
Unobstructed Forward Reach
Figure 308.2.1
Unobstructed High Forward Reach
Figure 308.3.2
Protruding Object Clearance
30
"
m
i
n
48" min
30" min
48
"
m
i
n
12" min
36" min
12" min
60
"
m
i
n
24
"
m
i
n
36
"
m
i
n
base
ar
m
ar
m
60" min
1. NOTE: ALL DIMENSIONS ARE MEASURED
FROM FLOOR, UNLESS NOTED OR SHOWN
OTHERWISE.
2. ADA UNOBSTRUCTED REACH RANGES: ADA
FORWARD REACH = 48”MAX. & 15”MIN. ADA
SIDE REACH = 48”MAX. & 15”MIN.
3. ELEVATORS: STANDARD CALL BUTTONS:
35”TO 48”TO C.L. & PROTRUDE 1”MAX. ADA
CALL BUTTONS: 42”TO C.L. (TYP.) & 48”MAX.
(3/4”SMALLEST DIM.). ADA VISIBLE SIGNALS:
72”MIN. TO C.L. (2 1/2”SMALLEST DIM.).
TACTILE SIGNAL ON HOISTWAY: 60”TO
BASE OF CHARACTERS W/ TACTILE STAR &
2”HIGH CHARACTERS.
4. DOOR HARDWARE (TO CENTER OF
HARDWARE): STANDARD MOUNTING
HEIGHTS: PUSH PLATES = 42", PULL
HANDLES = 42", KNOBS/ LEVERS = 40",
PANIC EXIT = 42" CENTERLINE OF BAR,
KICKPLATES: WIDTH = DOOR WIDTH MINUS
2”, CENTER, HEIGHT = 16”FROM B.O. DOOR.
THRESHOLDS: STANDARD = 1/2" MAX. AT
EXT. SLIDING DOORS = 3/4”MAX., ADA
HARDWARE = 34”MIN. TO 48”MAX.
5. DRINKING FOUNTAINS & EWC'S (TO SPOUT):
STANDARD = 38”MIN., 43" MAX. ADA =36"
MAX. (27" MIN. CLEAR KNEE SPACE)
6. COUNTERTOPS (TO SINK RIM/
COUNTERTOP): ADA = 28”MIN. TO 34" MAX.
7. WATER CLOSETS (TO TOP OF SEAT):
STANDARD = 14”TO 15". ADA (TO TOP OF
SEAT) = 17" TO 19”. ADA FLUSH CONTROLS =
44" MAX.
8. URINALS (TO RIM): STANDARD = 24" MAX.
ADA =17" MAX. ADA FLUSH CONTROLS = 44"
MAX.
9. LAVATORIES (TO SINK RIM/ COUNTERTOP):
STANDARD = 36" MAX. ADA = 34" MAX. (29"
MIN. CLEAR KNEE SPACE)
10. MIRRORS (TO B.O. REFLECTIVE SURFACE):
STANDARD = VARIES. ADA = 40" MAX.
11. GRAB BARS -ADA (TO TOP OF BAR): WATER
CLOSETS = 33”MIN. TO 36" MAX. SHOWERS
= 33”MIN. TO 36" MAX. (FROM B.O.SHOWER).
BATHTUBS: TOP BAR = 33”MIN. TO 36"
MAX. BOT. BAR = 9”ABOVE T.O. TUB
12. SHOWER HEADS (FROM FLOOR TO HEAD):
STANDARD = 72" TO 84”. ADA = SPRAY UNIT
W/ HOSE 60”LONG MIN. ADA = FIXED
SHOWER HEAD = 48”AFF.
13. SHOWER CONTROLS (TO CONTROL AREA):
STANDARD = 48”MAX. (TO TOP). ADA = 38"
MIN. TO 48" MAX.
14. SHOWER ROD (FROM FLOOR TO C.L.):
STANDARD = 78" MAX.
15. TOILET ROOM PARTITIONS: TOILETS = 12"
TO BOT. & 70”TO TOP. URINALS = 18" TO
BOT. & 60”TO TOP
16. TOILET PAPER DISPENSERS (TO C.L. OF
OUTLET): STANDARD = 24". ADA = 19”MIN.
TO 24" MAX.
17. WALL MOUNTED SOAP DISPENSERS (TO C.
L. OF PUSH BUTTON): STANDARD = 40". ADA
= VARIES. RE: OBSTRUCTED AND
UNOBSTRUCTED REACH RANGES. ADA
SIDE REACH = 46”MAX. ABOVE SINK
INCOUNTER.
18. PAPER TOWEL DISPENSER/ WASTE
RECEPTACLE (TO TOWEL SLOT):
STANDARD = 40" MAX. ADA FORWARD
REACH = 48”MAX. & 15”MIN. ADA SIDE
REACH = 48”MAX. & 15”MIN.
19. WARM AIR HAND DRYER (TO PUSH
SWITCH): STANDARD = 44" MAX. ADA
FORWARD REACH = 48”MAX. & 15”MIN. ADA
SIDE REACH = 48”MAX. & 15”MIN.
20. SANITARY NAPKIN DISPENSER (TO C.L. OF
COIN SLOT): STANDARD = 40" MAX. ADA
FORWARD REACH = 48”MAX. & 15”MIN. ADA
SIDE REACH = 48”MAX. & 15”MIN.
21. SANITARY NAPKIN DISPOSAL (TO TOP OF
UNIT): STANDARD = 28" MAX. ADA = 19”MIN.
TO 24" MAX. (TO OPNG.)
22. TOILET SEAT COVER DISPENSERS (TO
OPNG.): STANDARD = 40" MAX. ADA
FORWARD REACH = 48”MAX. & 15”MIN. ADA
SIDE REACH = 48”MAX. & 15”MIN.
23. SHELVES: ADA = 48" MAX.
24. COAT HOOKS: STANDARD = 68". ADA = 48"
MAX.
25. CHALKBOARDS, TACKBOARDS,&
MARKERBOARDS: STANDARD = 32" TO 39”
(TO B.O. BOARD OR CHALKTRAY).
STANDARD = 80”(RECOMMENDED, TO T.O.
BOARD)
26. THERMOSTATS & CONTROL DEVICES (TO
TOP): ADA FORWARD REACH = 48”MAX.
ADA SIDE REACH = 48”MAX.
27. LIGHT SWITCHES & CARD READERS (TO
C.L.): LOCATE 6”FROM DOOR JAMB. ADA =
48”MAX.
28. CONVENIENCE RECEPTACLES –
ELECTRICAL/ TELEPHONE/ DATA (TO C.L.):
STANDARD = 18". ADA = 15”MIN.
29. EXIT LIGHTS -WALL MOUNTED: 2" MIN.
BELOW CEILING. 2”MIN. ABOVE DOOR
FRAME. EQUAL SPACE FROM CEILING TO
TOP OF FRAME
30. FIRE EXTINGUISHERS (TO TOP, U.N.O.):
GROSS WT. 40 LBS. OR LESS = 60" MAX.
GROSS WT. MORE THAN 40 LBS. = 42" MAX.
ADA = 40" MAX. (B.O. CABINET)
31. FIRE ALARM PULL STATIONS (TO LEVER):
STANDARD = 48" MAX. ADA FORWARD
REACH = 48”MAX. ADA SIDE REACH = 48”
MAX.
32. SMOKE AND/OR HEAT DETECTORS:
STANDARD = CEILING HEIGHT
33. HORN/ SPEAKER/ VISUAL SIGNALS:
STANDARD = 80”AFF. OR 6”BELOW
CEILING -WHICHEVER IS LOWER.
34. ROOM SIGNAGE (TO C.L.): STANDARD = 60”
HIGH AFF. & WITHIN 18”OF LATCH SIDE OF
DOOR
GENERAL NOTES
ADA GUIDELINES
SHEET NUMBER
4040 N CENTRAL EXPY,
SUITE 720
DALLAS, TEXAS 75204
t 314.302.6864
www.modusarchitecture.com
FOR INFORMATION
PURPOSES ONLY. NOT TO
BE USED IN ANY CAPACITY
FOR BIDDING, PERMITTING,
OR CONSTRUCTION
REVISIONS:
SHEET NAME
ISSUE DATE:
16
2
5
L
A
N
C
A
S
T
E
R
D
R
I
V
E
GR
A
P
E
V
I
N
E
,
T
E
X
A
S
7
6
0
5
1
G002
ACCESSIBILITY
STANDARDS
PE
R
M
I
T
S
E
T
CO
O
K
C
H
I
L
D
R
E
N
'
S
12/19/2024
211.2 Minimum Number
No fewer than two drinking fountains shall be provided. One drinking fountain shall comply with
low spout height requirements and one with high spout requirements.
Exception: Where a single drinking fountain complies with both requirements, it shall
permitted to be substituted for two separate drinking fountains.
602.2 Clear Floor Space
Units shall have a clear floor or ground space complying with required Clear Floor Area and Knee
and Toe Clearances of 2012 TAS, positioned for a forward approach and centered on the unit.
602.3 Operable Parts
Controls shall be operable with one hand and shall not require tight grasping, pinching, or twisting
of the wrist. The force required to activate controls shall be no greater than 5 pounds maximum.
602.4 Spout Height
Spout outlets shall be 36" maximum above the finish floor.
602.5 Spout Location
The spout shall be located 15" minimum from the vertical support and 5" maximum from the front
edge of the unit, including bumpers.
602.7 Drinking Fountains for Standing Persons
Spout outlets of drinking fountains for standing persons shall be 38" minimum and 43" maximum
above the finish floor.
603.2 Clearances
• All accessible fixtures and controls shall be on an accessible route.
• Compliant turning space shall be provided within the room.
• Required clear floor spaces, clearance at fixtures, and turning space shall be permitted to overlap.
• Doors shall not swing into the clear floor space or clearance required for any fixture. Doors shall be
permitted to wing into the required turning space.
703 Signs
Where all toilet and bathrooms are not accessible, accessible toilet and bathrooms shall be identified by a
sign showing the International Symbol of Accessibility. Refer to Section 703 SIGNS.
604.2 Location
• The water closet shall be positioned with a wall or partition to the rear and to one side. The centerline of
the water closet shall be 16" minimum to 18" maximum from the side wall or partition,
• except that the water closet shall be 17: minimum and 19" maximum from the side wall or partition in
the ambulatory accessible toilet compartment.
• Clearance around a water closet shall be 60" minimum measured perpendicular from the side wall and
56" minimum measured perpendicular from the rear wall.
• The required clearance around the water closet shall be permitted to overlap the water closet,
associated grab bars, dispensers, sanitary napkin disposal units, coat hooks, shelves, accessible
routes, clear floor space and clearances required at other fixtures, and the turning space. No other
fixtures or obstructions shall be located within the required water closet clearance.
• When the door to a toilet room is placed directly in front of the water closet, the water closet cannot
overlap the required maneuvering clearance for the door inside the room.
604.4 Seats
The seat height of a water closet above the finish floor shall be 17" minimum and 19" maximum measured
to the top of the seat. Seats shall not be sprung to return to a lifted position.
604.5 Grab Bars
Grab bars shall be provided on the side wall closest to the water closet and on the rear wall, per section
609: GRAB BARS.
604.5.1 Side Wall
The side wall grab bar shall be 42" long minimum, located 12" maximum from the rear wall and extending
54" minimum from the rear wall.
604.5.2 Rear Wall
The rear wall grab bar shall be 36" long minimum and extend from the centerline of the water closet 12"
minimum on one side and 24" minimum on the other side.
604.6 Flush Controls
• Controls shall be hand operated or automatic.
• Controls shall be located on the open side of the water closet
• Controls shall be operable with one hand and shall not require tight grasping, pinching, or twisting of
the wrist.
• The force required to activate controls shall be no greater than 5 pound maximum.
604.7 Dispensers
Toilet paper dispensers shall be installed on the side wall, below the grab bar, 7" minimum and 9" maximum
in front of the water closet measured to the centerline of the dispenser. The outlet of the dispenser shall be
15" minimum and 48" maximum above the finish floor and shall not be located behind grab bar.
Dispensers shall not be of a type that controls delivery or that does not allow continuous paper flow.
604.8 Toilet Compartments
Standard Wheelchair Accessible Compartments shall be:
• 60" wide minimum measured perpendicular to the side wall.
• 59" deep minimum for floor mounted water closets, and 56" deep minimum for wall hung water closets,
measured perpendicular to the rear wall.
• The required minimum space cannot be obstructed by baby changing tables or other fixtures or
conveniences, except as specified in Overlap.
• Toilet compartment doors, including door hardware, shall comply with 404 DOORS, except that if the
approach is to the latch side of the compartment door, clearance between the door side of the
compartment and any obstruction shall be 42" minimum. Doors shall be located in the front partition or
in the side wall or partition farthest from the water closet. Where located in the front partition, the door
opening shall be 4" maximum from the side wall or partition farthest from the water closet. Where
located in the side wall or partition, the door opening shall be 4" maximum from the from front partition.
The door shall be self-closing. A door pull be placed on both sides of the door near the latch. Toilet
compartment doors shall not swing into the minimum required compartment area. Clear width of
opening at door shall be 32" minimum, per DOORS 404.2.3.
• Toe Clearance: The front partition and at least one side partition shall provide a toe clearance of 9"
minimum above the finish floor and 6" deep minimum beyond the compartment-side face of the
partition, exclusive of partition support members.
Ambulatory Accessible Compartments (required when more than 6 water closets or combination of water
closets and urinals are provided) shall be:
• 60" minimum deep,
• 35" minimum and 37" maximum wide.
• Doors shall not swing into the minimum required compartment area.
• A side grab bar shall be provided on both sides of the compartment.
608.3 Coat Hooks & Shelves
Coat hooks shall be located within one of the reach ranges in 308 Reach Ranges. Shelves shall be located
40" Minimum and 48" maximum above finish floor.
606.2 Clear Floor Space
A clear floor space 30" by 48", positioned for a forward approach, and required Knee and Toe Clearances
shall be provided. The clear floor space shall adjoin or overlap an accessible route.
606.3 Height
Lavatories and sinks shall be installed with the front of the higher of the rim or counter surface 34"
maximum above the finish floor or ground.
606.4 Faucets
• Controls shall be operable with one hand and shall not require tight grasping, pinching, or twisting
or the write.
• The force required to activate controls shall be no greater than 5 pounds maximum.
• Hand-operated metering faucets shall remain open from 10 seconds minimum.
606.5 Exposed Pipes and Surfaces
Water supply and drain pipes under lavatories and sinks shall be insulated or otherwise configured to
protect against contact. There shall be no sharp or abrasive surfaces under lavatories and sinks.
603.3 Mirrors
• Mirrors located above lavatories or countertops shall be installed with the bottom edge of the
reflection surface 40" maximum above the finish floor. Mirrors not located above lavatories or
countertops shall be installed with the bottom edge of the reflecting 35" maximum above the finish
floor.
• A single full-length mirror can accommodate a greater number of people including children. In order
for mirrors to be usable by people who are ambulatory and people who use wheelchairs, the top
edge of mirrors should be 74" minimum from finish floor.
609.2 & 609.3 Cross Section and Spacing
Grab bars with circular cross sections shall have an outside diameter of 1 14" minimum and 2" maximum.
Grab bars with non-circular cross sections shall have a cross section dimension of 2 inches maximum and
a perimeter dimension of 4" minimum and 4.8" maximum. The space between grab bars and adjacent walls
shall be 1-1/2".
609.4 Position of Grab Bars
Grab bars shall be installed in a horizontal position, 3" minimum and 36" maximum above the finish floor
measured to the top of the gripping surface, expect that at children's water closet grab bars shall be
installed 18" minimum and 27" maximum above finish floor.
609.5 Surface Hazards
Grab bars and any wall or other surfaces adjacent to grab bars shall be free of sharp or abrasive elements
and shall have rounded edges.
609.6 Fittings
Grab bars shall not rotate in their fittings.
609.8 Structural Strength
Allowable stresses shall not be exceeded for materials used when a vertical or horizontal force of 250
pounds is applied at any point on the grab bar, fastener, mounting device, or supporting structure.
610.3 Shower Compartment Seats
• Where a seat is provided in a standard roll-in shower, it shall be a folding type, shall be installed on the
side wall adjacent to the controls, and shall extend from the back wall to a point within 3" of the
compartment entry.
• Where a seat is provided in an alternate roll-in type shower, it shall be a folding type, shall be installed
on the front wall opposite the back wall, and shall extend from the adjacent side wall to a point within 3"
of the compartment entry.
• In transfer-type showers, the seat shall extend from the back wall to a point within 3" of the
compartment entry.
• The top of the seat shall be 17" and 19" maximum above the bathroom finish floor.
610.3.1 Rectangular Seats
The rear edge of a rectangular seat shall be 2 1/2" maximum, and the front edge shall be 15" minimum and
16" maximum from the seat wall. The side edge of the seat shall be 1 1/2" maximum from the adjacent wall.
610.3.2 L-Shaped Seats
The rear edge of an L-shaped seat shall be 2 1/2" maximum, and the front edge 15" minimum and 16"
maximum from the seat wall. The rear edge of the "L" portion of the seat shall be 1 1/2" maximum from the
wall and the front edge shall be 14" minimum and 15" maximum from the wall. The end of the "L" shall be
22" minimum and 23" maximum from the main seat wall.
610.4 Structural Strength
Allowable stresses shall not be exceeded for materials used when a vertical or horizontal force of 250
pounds is applied at any point on the seat, fastener, mounting device, or supporting structure.
316.2 Designations
Interior and exterior signs identifying permanent rooms and spaces shall comply with the requirements for:
• Raised and Braille Characters and Pictograms
• Finish and Contrast
• Mounting Locations and Heights
703.1 Where Applicable
Elements and spaces of accessible facilities which shall be identified by the International Symbol of
Accessibility are:
• Parking spaces designated as reserved for persons with disabilities;
• Accessible passenger loading zones;
• Accessible entrances when not all are accessible (inaccessible entrances shall have directional
signage to indicate route to nearest accessible entrance);
• Accessible toilet and bathing facilities when not all are accessible.
703.2 Raised Characters
Raised characters shall be:
• 1/32" minimum above their background,
• uppercase,
• sans serif (not italic, oblique, script, highly decorative, or other unusual forms),
• a font where width of uppercase letter "O" is 55% minimum and 110% maximum of the height of
uppercase letter "I",
• height measured vertically from the baseline of the character shall be 5/8" minimum and 2" maximum
based on the height of the uppercase letter "I".
• (Refer to full text of 2012 TAS for signs mounted greater than 70" above finish floor.)
703.3 Braille
• Braille shall be Grade 2 and positioned below the corresponding text.
• (Refer to full text of 2012 TAS for specifics of Braille requirements.)
703.4 Installation Height and Location
• Tactile characters on signs shall be located 48" minimum and above all the finish floor or ground
surface, measured from the baseline of the lowest tactile character and 60" maximum above the finish
floor or ground surface, measured from the baseline of the highest tactile character.
• Where a tactile sign is provided at a door, the sign shall be located alongside the door at the latch side.
Where a tactile sign is provided at a door, the sign shall be located alongside the door at the latch the
inactive leaf. Where a tactile sign is provided at double doors with two active leafs, the sign shall be
located to the right of the right hand door.
703.5.1 Finish and Contrast
Characters and their background shall have a non-glare finish. Characters shall contrast with their
background with either light characters on a dark background or dark characters on a light background.
703.6 Pictograms
Pictograms shall have a field height of 6" minimum. Characters and braille shall not be located in the
pictogram field. Pictograms and their field shall have a non-glare finish. Pictograms shall contrast with their
field with either a light pictogram on a dark field or a dark pictogram on a light field. Pictograms shall have
text descriptors located directly below the pictogram field.
703.7 Symbols of Accessibility
• Facilities and elements required to be identified as accessible shall use the International Symbol of
Accessibility.
• Text Telephones, when required, shall be identified by the International TTY symbol.
• Volume Control Telephones, When required, shall be identified by a pictogram of a telephone handset
with radiating sound waves on a square field.
• Assistive Listening Systems, when required, shall be identified by the International Symbol of Access
for Hearing Loss.
602: DRINKING FOUNTAINS
603: TOILET AND BATHING ROOMS
606: LAVATORIES & SINKS / 603: MIRRORS
610: SEATS
609: GRAB BARS
703: SIGNS
5" max 15" min
fo
r
s
t
a
n
d
i
n
g
p
e
r
s
o
n
38
"
m
i
n
t
o
4
8
"
m
a
x
t
o
s
p
o
u
t
36
"
m
a
x
t
o
s
p
o
u
t
27
"
m
i
n
9"
m
i
n
6" max8" min
604: WATER CLOSETS AND TOILET COMPARTMENTS
33
"
t
o
3
6
"
42" min
54" min
12" max
6' - 10 3/4"
12" min
24" min
17
"
-
1
9
"
transfer
side
48
"
m
a
x
15
"
m
i
n
7"-9"
9"
m
i
n
6" min
partition
6" min
6"
m
i
n
planelevation
4"
m
a
x
4" max
42
"
m
i
n
alternate
door
location
42
"
m
i
n
35" - 37"
60
"
m
i
n
17" - 19"
16" - 18"
56
"
m
i
n
60" min
16" - 18"
59
"
m
i
n
60" min
34
"
m
a
x
bo
t
t
o
m
o
f
m
i
r
r
o
r
40
"
m
a
x
t
o
2 1/2" max
3"
m
a
x
1
1
/
2
"
m
a
x
seat
wall
seat
wall
seat
wall
1
1
/
2
"
m
a
x
3"
m
a
x
2 1/2" maxcompartment
entry
compartment
entry
22" - 23"
14
"
-
1
5
"
15" - 16"
15" - 16"
centered on 18"x18"
clear space
AREA OF
REFUGE
clear space
18" min
cl
e
a
r
s
p
a
c
e
18
"
m
i
n
centered on tactile
characters
6"
m
i
n
Side & Rear Wall Grab Bars
Figure 604.5.1 & 604.5.2
Dispenser Outlet Location
Figure 604.7
(b)
distance from wall
(a)
size
Size of Wheelchair Accessible Compartment
Figure 604.8.1.1
Wheelchair Accessible
Compartment Doors
Figure 604.8.1.2
Ambulatory Accessible Compartment
Figure 604.8.2
Wheelchair Accessible Compartment Toe Clearance
Figure 604.8.1.4
(a)
wall hung water closet
(b)
floor mounted water closet
not in
pictogram
field
Height of Tactile Characters Above Finish Floor
Figure 703.4.1
Location of Tactile Signs at Doors
Figure 703.4.2
Pictorgram Field
Figure 703.6.1
International Symbol of
Accessibility
Figure 703.7.2.1
TTY Volume Control Hearing Loss
48
"
m
i
x
60
"
m
a
x
1. NOTE: ALL DIMENSIONS ARE MEASURED
FROM FLOOR, UNLESS NOTED OR SHOWN
OTHERWISE.
2. ADA UNOBSTRUCTED REACH RANGES: ADA
FORWARD REACH = 48”MAX. & 15”MIN. ADA
SIDE REACH = 48”MAX. & 15”MIN.
3. ELEVATORS: STANDARD CALL BUTTONS:
35”TO 48”TO C.L. & PROTRUDE 1”MAX. ADA
CALL BUTTONS: 42”TO C.L. (TYP.) & 48”MAX.
(3/4”SMALLEST DIM.). ADA VISIBLE SIGNALS:
72”MIN. TO C.L. (2 1/2”SMALLEST DIM.).
TACTILE SIGNAL ON HOISTWAY: 60”TO
BASE OF CHARACTERS W/ TACTILE STAR &
2”HIGH CHARACTERS.
4. DOOR HARDWARE (TO CENTER OF
HARDWARE): STANDARD MOUNTING
HEIGHTS: PUSH PLATES = 42", PULL
HANDLES = 42", KNOBS/ LEVERS = 40",
PANIC EXIT = 42" CENTERLINE OF BAR,
KICKPLATES: WIDTH = DOOR WIDTH MINUS
2”, CENTER, HEIGHT = 16”FROM B.O. DOOR.
THRESHOLDS: STANDARD = 1/2" MAX. AT
EXT. SLIDING DOORS = 3/4”MAX., ADA
HARDWARE = 34”MIN. TO 48”MAX.
5. DRINKING FOUNTAINS & EWC'S (TO SPOUT):
STANDARD = 38”MIN., 43" MAX. ADA =36"
MAX. (27" MIN. CLEAR KNEE SPACE)
6. COUNTERTOPS (TO SINK RIM/
COUNTERTOP): ADA = 28”MIN. TO 34" MAX.
7. WATER CLOSETS (TO TOP OF SEAT):
STANDARD = 14”TO 15". ADA (TO TOP OF
SEAT) = 17" TO 19”. ADA FLUSH CONTROLS =
44" MAX.
8. URINALS (TO RIM): STANDARD = 24" MAX.
ADA =17" MAX. ADA FLUSH CONTROLS = 44"
MAX.
9. LAVATORIES (TO SINK RIM/ COUNTERTOP):
STANDARD = 36" MAX. ADA = 34" MAX. (29"
MIN. CLEAR KNEE SPACE)
10. MIRRORS (TO B.O. REFLECTIVE SURFACE):
STANDARD = VARIES. ADA = 40" MAX.
11. GRAB BARS -ADA (TO TOP OF BAR): WATER
CLOSETS = 33”MIN. TO 36" MAX. SHOWERS
= 33”MIN. TO 36" MAX. (FROM B.O.SHOWER).
BATHTUBS: TOP BAR = 33”MIN. TO 36"
MAX. BOT. BAR = 9”ABOVE T.O. TUB
12. SHOWER HEADS (FROM FLOOR TO HEAD):
STANDARD = 72" TO 84”. ADA = SPRAY UNIT
W/ HOSE 60”LONG MIN. ADA = FIXED
SHOWER HEAD = 48”AFF.
13. SHOWER CONTROLS (TO CONTROL AREA):
STANDARD = 48”MAX. (TO TOP). ADA = 38"
MIN. TO 48" MAX.
14. SHOWER ROD (FROM FLOOR TO C.L.):
STANDARD = 78" MAX.
15. TOILET ROOM PARTITIONS: TOILETS = 12"
TO BOT. & 70”TO TOP. URINALS = 18" TO
BOT. & 60”TO TOP
16. TOILET PAPER DISPENSERS (TO C.L. OF
OUTLET): STANDARD = 24". ADA = 19”MIN.
TO 24" MAX.
17. WALL MOUNTED SOAP DISPENSERS (TO C.
L. OF PUSH BUTTON): STANDARD = 40". ADA
= VARIES. RE: OBSTRUCTED AND
UNOBSTRUCTED REACH RANGES. ADA
SIDE REACH = 46”MAX. ABOVE SINK
INCOUNTER.
18. PAPER TOWEL DISPENSER/ WASTE
RECEPTACLE (TO TOWEL SLOT):
STANDARD = 40" MAX. ADA FORWARD
REACH = 48”MAX. & 15”MIN. ADA SIDE
REACH = 48”MAX. & 15”MIN.
19. WARM AIR HAND DRYER (TO PUSH
SWITCH): STANDARD = 44" MAX. ADA
FORWARD REACH = 48”MAX. & 15”MIN. ADA
SIDE REACH = 48”MAX. & 15”MIN.
20. SANITARY NAPKIN DISPENSER (TO C.L. OF
COIN SLOT): STANDARD = 40" MAX. ADA
FORWARD REACH = 48”MAX. & 15”MIN. ADA
SIDE REACH = 48”MAX. & 15”MIN.
21. SANITARY NAPKIN DISPOSAL (TO TOP OF
UNIT): STANDARD = 28" MAX. ADA = 19”MIN.
TO 24" MAX. (TO OPNG.)
22. TOILET SEAT COVER DISPENSERS (TO
OPNG.): STANDARD = 40" MAX. ADA
FORWARD REACH = 48”MAX. & 15”MIN. ADA
SIDE REACH = 48”MAX. & 15”MIN.
23. SHELVES: ADA = 48" MAX.
24. COAT HOOKS: STANDARD = 68". ADA = 48"
MAX.
25. CHALKBOARDS, TACKBOARDS,&
MARKERBOARDS: STANDARD = 32" TO 39”
(TO B.O. BOARD OR CHALKTRAY).
STANDARD = 80”(RECOMMENDED, TO T.O.
BOARD)
26. THERMOSTATS & CONTROL DEVICES (TO
TOP): ADA FORWARD REACH = 48”MAX.
ADA SIDE REACH = 48”MAX.
27. LIGHT SWITCHES & CARD READERS (TO
C.L.): LOCATE 6”FROM DOOR JAMB. ADA =
48”MAX.
28. CONVENIENCE RECEPTACLES –
ELECTRICAL/ TELEPHONE/ DATA (TO C.L.):
STANDARD = 18". ADA = 15”MIN.
29. EXIT LIGHTS -WALL MOUNTED: 2" MIN.
BELOW CEILING. 2”MIN. ABOVE DOOR
FRAME. EQUAL SPACE FROM CEILING TO
TOP OF FRAME
30. FIRE EXTINGUISHERS (TO TOP, U.N.O.):
GROSS WT. 40 LBS. OR LESS = 60" MAX.
GROSS WT. MORE THAN 40 LBS. = 42" MAX.
ADA = 40" MAX. (B.O. CABINET)
31. FIRE ALARM PULL STATIONS (TO LEVER):
STANDARD = 48" MAX. ADA FORWARD
REACH = 48”MAX. ADA SIDE REACH = 48”
MAX.
32. SMOKE AND/OR HEAT DETECTORS:
STANDARD = CEILING HEIGHT
33. HORN/ SPEAKER/ VISUAL SIGNALS:
STANDARD = 80”AFF. OR 6”BELOW
CEILING -WHICHEVER IS LOWER.
34. ROOM SIGNAGE (TO C.L.): STANDARD = 60”
HIGH AFF. & WITHIN 18”OF LATCH SIDE OF
DOOR
GENERAL NOTES
ADA GUIDELINES
SHEET NUMBER
4040 N CENTRAL EXPY,
SUITE 720
DALLAS, TEXAS 75204
t 314.302.6864
www.modusarchitecture.com
FOR INFORMATION
PURPOSES ONLY. NOT TO
BE USED IN ANY CAPACITY
FOR BIDDING, PERMITTING,
OR CONSTRUCTION
REVISIONS:
SHEET NAME
ISSUE DATE:
16
2
5
L
A
N
C
A
S
T
E
R
D
R
I
V
E
GR
A
P
E
V
I
N
E
,
T
E
X
A
S
7
6
0
5
1
G003
ACCESSIBILITY
STANDARDS
PE
R
M
I
T
S
E
T
CO
O
K
C
H
I
L
D
R
E
N
'
S
12/19/2024
Letters and numbers on signs shall have a
width to height ratio of between 3:5 and 1:1
and a stroke -width to height ratio between
1:5 & 1:10. Letters and numbers shall be
raised 1/32" upper case, sans serif or simple
serif type and shall be accompanied with
grade 2 Braille, raised characters shall be at
least 5/8" high, but no higher than 2".
Detail 16.2Detail 16.1
International symbol
of Accessibility
Detail 16.3
Light switch,
Thermostats,
etc...
Convenience Outlets,
Data, Tele, etc...
4'
-
6
"
(
S
I
D
E
)
Note:
This signage applies
to all code compliant
signage requirements
including by not
limited to rooms of
the following type:
mech rooms, sprinkler
riser room, fire
detection control
rooms.
1' - 0"
1'
-
6
"
NE STAIR
NO ROOF ACCESS
1
B3 THROUGH 17
MI
N
1
1
/
2
"
MI
N
1"
5"
M
I
N
MI
N
1"
*NOTES:
1) INFORMATION ON SIGN TO BE SPECIFIC FOR EACH
INSTALLATION LOCATION. INFORMATION SHOWN IN DETAIL IS FOR
EXAMPLE ONLY.
2) ALL CHARACTERS TO BE UPPER-CASE.
3) CHARACTERS AND BACKGROUND SHALL HAVE NON-GLARE
FINISH.
4) CHARACTERS SHALL CONTRAST WITH BACKGROUND.
5) ALL STAIRWAY IDENTIFICATION SIGNS TO BE MADE OF SELF-
LUMINOUS AND/OR PHOTOLUMINESCENT MATERIALS EXCEPT AT
RESIDENTIAL (R-2) STAIRS #1 & 2.
5'
-
0
"
A
F
F
EXIT DISCHARGE
THIS LEVEL
STAIR ID
AVAILABILITY
OF ROOF
ACCESS
FLOOR
LEVEL
TOP &
BOTTOM
TERMINUS
LEVEL OF AND
DIRECTION TO
EXIT
DISCHARGE
MI
N
1"
6"
AS
R
E
Q
EXIT
*NOTES:
1) TACTILE EXIT SIGNS TO BE PROVIDED AT ALL EXIT STAIRWAYS,
EXIT RAMPS, EXIT PASSAGEWAYS AND EXIT DISCHARGES.
2) ALL CHARACTERS TO BE UPPER-CASE.
3) CHARACTERS AND BACKGROUND SHALL HAVE NON-GLARE
FINISH.
4) CHARACTERS SHALL CONTRAST WITH BACKGROUND.
5) CHARACTERS SHALL BE RAISED 1/32" MINIMUM ABOVE THEIR
BACKGROUND.
6) ALL FLOOR LEVEL SIGNS SHALL COMPLY WITH ICC A117.1.
7) VERIFY REQUIRED SIGN LOCATIONS WITH ARCHITECT IN
SUBMITTAL PRIOR TO FABRICATION AND INSTALLATION. REFER TO
GL (LIFE SAFETY SHEETS FOR EXIT AND EXIT STAIR LOCATIONS.
48
"
M
I
N
AF
F
MI
N
3/
8
"
MI
N
3/
8
"
MI
N
3/
8
"
GRADE II
BRAILLE
ON LATCH SIDE
9" MIN TO DOOR EDGE
DOOR
FRAME
60
"
M
A
X
AF
F
6"
AS
R
E
Q
LEVEL 2
*NOTES:
1) INFORMATION ON SIGN TO BE SPECIFIC FOR EACH
INSTALLATION LOCATION. INFORMATION SHOWN IN DETAIL IS FOR
EXAMPLE ONLY.
2) ALL CHARACTERS TO BE UPPER-CASE.
3) CHARACTERS AND BACKGROUND SHALL HAVE NON-GLARE
FINISH.
4) CHARACTERS SHALL CONTRAST WITH BACKGROUND.
5) CHARACTERS SHALL BE RAISED 1/32" MINIMUM ABOVE THEIR
BACKGROUND.
6) ALL FLOOR LEVEL SIGNS SHALL COMPLY WITH ICC A117.1.
48
"
M
I
N
AF
F
FLOOR
LEVEL
MI
N
3/
8
"
MI
N
3/
8
"
MI
N
3/
8
"
BRAILLE
ON LATCH SIDE
9" MIN TO DOOR EDGE
DOOR
FRAME
60
"
M
A
X
AF
F
1 1/2" O.D. (SS OR
CHROME)
GRAB BAR SUPPORTS
250 LBS FORCE (TYP.)
TO
T
.
O
.
B
A
R
2'
-
9
"
T
O
3
'
-
0
"
B.
O
.
O
P
E
N
I
N
G
1'
-
6
"
M
I
N
.
WATER CLOSET
FLUSH HANDLES
SHALL BE LOCATED
ON THE TRANSFER
SIDE OF THE STOOL
2' - 0" MIN.
MIN.
1' - 0"
TO
B
.
O
.
B
A
R
39
"
T
O
4
1
"
1'
-
6
"
M
I
N
.
1' - 6" MAX.
1' - 4" MIN.
VERTICAL GRAB BAR
18" MIN
DISPENSER
1 1/2" O.D. ( SS OR
CHROME )
GRAB BAR SUPPORTS
250 LBS FORCE (TYP.)
3' - 6" MIN.1' - 0" MAX.
TO
T
.
O
.
B
A
R
2'
-
9
"
T
O
3
'
-
0
"
1 1/2"
T.
O
.
O
P
E
N
I
N
G
4'
-
0
"
M
A
X
.
DISPENSER
39" TO 41"
MI
N
.
1'
-
6
"
TO
B
.
O
.
B
A
R
39
"
T
O
4
1
"
1
1
/
2
"
7" TO 9"
B.
O
.
O
P
E
N
I
N
G
1'
-
6
"
M
I
N
.
VERTICAL
GRAB BAR 18"
MIN.
4' - 6" MIN.
MAX.
3' - 0"
2'-0" MIN.
3'-0" MAX.
1'
-
5
"
TOILET
PARTITION
1 1/2" O.D. (SS OR CHROME)
GRAB BAR SUPPORTS
250 LBS FORCE (TYP.)
2'
-
8
"
C
L
E
A
R
3'
-
0
"
M
I
N
.
4'
-
1
1
"
F
O
R
F
L
O
O
R
M
T
D
.
W
.
C
.
4'
-
8
"
F
O
R
W
A
L
L
M
T
D
.
W
.
C
.
5' - 0" CLEAR
1 - 5".2' - 0"
MA
X
.
1'
-
0
"
3'
-
6
"
M
I
N
.
4'
-
6
"
M
I
N
.
VERTICAL GRAB
BAR 18" MIN.
3"
CLEAR
FLOOR
SPACE
1 1/2" O.D. (SS OR CHROME)
GRAB BAR SUPPORTS
250 LBS FORCE (TYP.)
4'
-
1
1
"
F
O
R
F
L
O
O
R
M
T
D
.
W
.
C
.
4'
-
8
"
F
O
R
W
A
L
L
H
U
N
G
W
.
C
.
5' - 0"
1' - 5".
VERTICAL GRAB
BAR 18" MIN.
NOTE: PARTITION DOOR IS
TO BE LOCATED OPPOSITE
OF W.C. LOCATION
INSTALL @ 1' - 5"
CODE: 1' - 4" MIN. / 1' - 6" MAX.
SANITARY
NAPKIN
DISPOSAL
TOILET
PAPER
DISPENSER
1'
-
7
"
M
I
N
.
SOAP DISPENSER
( 4" MAX. PROJ. )
MIRROR
PAPER TOWEL
DISPENSER
( 4" MAX.
PROJ. )3'
-
4
"
M
A
X
.
4'
-
0
"
M
A
X
.
4'
-
0
"
M
A
X
.
TO
B
O
T
T
O
M
O
F
RE
F
L
E
C
T
I
V
E
SU
R
F
A
C
E
3'
-
1
1
1
/
8
"
SE
E
N
O
T
E
#
1
7
6'
-
2
"
M
I
N
.
T
O
T
O
P
O
F
RE
F
L
E
C
T
I
V
E
S
U
R
F
A
C
E
U
.
N
.
O
.
CLEAR
FLOOR
SPACE
11" MIN.
9"
M
I
N
.
2'
-
3
"
M
I
N
.
2' - 1" MAX.
1' - 5" MIN.
TO
P
O
F
S
I
N
K
R
I
M
O
R
C
O
U
N
T
E
R
2'
-
1
0
"
M
A
X
T
O
H
I
G
H
E
R
O
F
2' - 6" MIN.
4'
-
0
"
M
I
N
.
2'
-
1
'
M
A
X
.
1'
-
5
"
M
I
N
.
PLAN
SECTION
6" MAX.
8" MIN.
LINE OF WHEELCHAIR
LIGHT SWITCH
4'
-
0
"
M
A
X
.
MAX.
1' - 0"
2"
THERMOSTAT
1'
-
3
"
M
I
N
.
RECEPTACLE
CENTERLINE OF
CABINET HANDLE OR
CENTERLINE OF F.E.
HANDEL IF HUNG
INSIDE CABINET
4'
-
0
"
M
A
X
.
SEMI-RECESSED
FIRE EXTINGUISHER
CABINET
1
1
/
2
"
M
I
N
.
1 1/4" TO 2"
4 1/2" MAX.
1 1/2" MIN.
2X F.R. WOOD
BLOCKING
AT PERIMETER OF
ACCESSORY
SEMI-RECESSED
F.E.C./ TOILET
ACCESSORY PER
SCHEDULE
(NON-RATED WALLS)
SURFACE
MOUNTED TOILET
ACCESSORY
PER SCHEDULE
2"X10" F.R.
WOOD
BLOCKING
AS REQUIRED
4" MAX.
HANDRAIL OR
GRAB BAR
4" MAXIMUM
2"X10" F.R.
WOOD
BLOCKING AS
REQUIRED
2X F.R. WOOD
BLOCKING
AT PERIMETER OF
ACCESSORY
SEMI-RECESSED
F.E.C./ TOILET
ACCESSORY
PER SCHEDULE
4" MAX.
AT RECESS OPENINGS IN
FIRE RATED
CONSTRUCTION ONLY.
EXTEND GYP. BOARD
CONTINUOUSLY ALONG
RECESS AS INDICATED BY
DASHED LINE
1. NOTE: ALL DIMENSIONS ARE MEASURED
FROM FLOOR, UNLESS NOTED OR SHOWN
OTHERWISE.
2. ADA UNOBSTRUCTED REACH RANGES: ADA
FORWARD REACH = 48”MAX. & 15”MIN. ADA
SIDE REACH = 48”MAX. & 15”MIN.
3. ELEVATORS: STANDARD CALL BUTTONS:
35”TO 48”TO C.L. & PROTRUDE 1”MAX. ADA
CALL BUTTONS: 42”TO C.L. (TYP.) & 48”MAX.
(3/4”SMALLEST DIM.). ADA VISIBLE SIGNALS:
72”MIN. TO C.L. (2 1/2”SMALLEST DIM.).
TACTILE SIGNAL ON HOISTWAY: 60”TO
BASE OF CHARACTERS W/ TACTILE STAR &
2”HIGH CHARACTERS.
4. DOOR HARDWARE (TO CENTER OF
HARDWARE): STANDARD MOUNTING
HEIGHTS: PUSH PLATES = 42", PULL
HANDLES = 42", KNOBS/ LEVERS = 40",
PANIC EXIT = 42" CENTERLINE OF BAR,
KICKPLATES: WIDTH = DOOR WIDTH MINUS
2”, CENTER, HEIGHT = 16”FROM B.O. DOOR.
THRESHOLDS: STANDARD = 1/2" MAX. AT
EXT. SLIDING DOORS = 3/4”MAX., ADA
HARDWARE = 34”MIN. TO 48”MAX.
5. DRINKING FOUNTAINS & EWC'S (TO SPOUT):
STANDARD = 38”MIN., 43" MAX. ADA =36"
MAX. (27" MIN. CLEAR KNEE SPACE)
6. COUNTERTOPS (TO SINK RIM/
COUNTERTOP): ADA = 28”MIN. TO 34" MAX.
7. WATER CLOSETS (TO TOP OF SEAT):
STANDARD = 14”TO 15". ADA (TO TOP OF
SEAT) = 17" TO 19”. ADA FLUSH CONTROLS =
44" MAX.
8. URINALS (TO RIM): STANDARD = 24" MAX.
ADA =17" MAX. ADA FLUSH CONTROLS = 44"
MAX.
9. LAVATORIES (TO SINK RIM/ COUNTERTOP):
STANDARD = 36" MAX. ADA = 34" MAX. (29"
MIN. CLEAR KNEE SPACE)
10. MIRRORS (TO B.O. REFLECTIVE SURFACE):
STANDARD = VARIES. ADA = 40" MAX.
11. GRAB BARS -ADA (TO TOP OF BAR): WATER
CLOSETS = 33”MIN. TO 36" MAX. SHOWERS
= 33”MIN. TO 36" MAX. (FROM B.O.SHOWER).
BATHTUBS: TOP BAR = 33”MIN. TO 36"
MAX. BOT. BAR = 9”ABOVE T.O. TUB
12. SHOWER HEADS (FROM FLOOR TO HEAD):
STANDARD = 72" TO 84”. ADA = SPRAY UNIT
W/ HOSE 60”LONG MIN. ADA = FIXED
SHOWER HEAD = 48”AFF.
13. SHOWER CONTROLS (TO CONTROL AREA):
STANDARD = 48”MAX. (TO TOP). ADA = 38"
MIN. TO 48" MAX.
14. SHOWER ROD (FROM FLOOR TO C.L.):
STANDARD = 78" MAX.
15. TOILET ROOM PARTITIONS: TOILETS = 12"
TO BOT. & 70”TO TOP. URINALS = 18" TO
BOT. & 60”TO TOP
16. TOILET PAPER DISPENSERS (TO C.L. OF
OUTLET): STANDARD = 24". ADA = 19”MIN.
TO 24" MAX.
17. WALL MOUNTED SOAP DISPENSERS (TO C.
L. OF PUSH BUTTON): STANDARD = 40". ADA
= VARIES. RE: OBSTRUCTED AND
UNOBSTRUCTED REACH RANGES. ADA
SIDE REACH = 46”MAX. ABOVE SINK
INCOUNTER.
18. PAPER TOWEL DISPENSER/ WASTE
RECEPTACLE (TO TOWEL SLOT):
STANDARD = 40" MAX. ADA FORWARD
REACH = 48”MAX. & 15”MIN. ADA SIDE
REACH = 48”MAX. & 15”MIN.
19. WARM AIR HAND DRYER (TO PUSH
SWITCH): STANDARD = 44" MAX. ADA
FORWARD REACH = 48”MAX. & 15”MIN. ADA
SIDE REACH = 48”MAX. & 15”MIN.
20. SANITARY NAPKIN DISPENSER (TO C.L. OF
COIN SLOT): STANDARD = 40" MAX. ADA
FORWARD REACH = 48”MAX. & 15”MIN. ADA
SIDE REACH = 48”MAX. & 15”MIN.
21. SANITARY NAPKIN DISPOSAL (TO TOP OF
UNIT): STANDARD = 28" MAX. ADA = 19”MIN.
TO 24" MAX. (TO OPNG.)
22. TOILET SEAT COVER DISPENSERS (TO
OPNG.): STANDARD = 40" MAX. ADA
FORWARD REACH = 48”MAX. & 15”MIN. ADA
SIDE REACH = 48”MAX. & 15”MIN.
23. SHELVES: ADA = 48" MAX.
24. COAT HOOKS: STANDARD = 68". ADA = 48"
MAX.
25. CHALKBOARDS, TACKBOARDS,&
MARKERBOARDS: STANDARD = 32" TO 39”
(TO B.O. BOARD OR CHALKTRAY).
STANDARD = 80”(RECOMMENDED, TO T.O.
BOARD)
26. THERMOSTATS & CONTROL DEVICES (TO
TOP): ADA FORWARD REACH = 48”MAX.
ADA SIDE REACH = 48”MAX.
27. LIGHT SWITCHES & CARD READERS (TO
C.L.): LOCATE 6”FROM DOOR JAMB. ADA =
48”MAX.
28. CONVENIENCE RECEPTACLES –
ELECTRICAL/ TELEPHONE/ DATA (TO C.L.):
STANDARD = 18". ADA = 15”MIN.
29. EXIT LIGHTS -WALL MOUNTED: 2" MIN.
BELOW CEILING. 2”MIN. ABOVE DOOR
FRAME. EQUAL SPACE FROM CEILING TO
TOP OF FRAME
30. FIRE EXTINGUISHERS (TO TOP, U.N.O.):
GROSS WT. 40 LBS. OR LESS = 60" MAX.
GROSS WT. MORE THAN 40 LBS. = 42" MAX.
ADA = 40" MAX. (B.O. CABINET)
31. FIRE ALARM PULL STATIONS (TO LEVER):
STANDARD = 48" MAX. ADA FORWARD
REACH = 48”MAX. ADA SIDE REACH = 48”
MAX.
32. SMOKE AND/OR HEAT DETECTORS:
STANDARD = CEILING HEIGHT
33. HORN/ SPEAKER/ VISUAL SIGNALS:
STANDARD = 80”AFF. OR 6”BELOW
CEILING -WHICHEVER IS LOWER.
34. ROOM SIGNAGE (TO C.L.): STANDARD = 60”
HIGH AFF. & WITHIN 18”OF LATCH SIDE OF
DOOR
GENERAL NOTES
ADA GUIDELINES
SHEET NUMBER
4040 N CENTRAL EXPY,
SUITE 720
DALLAS, TEXAS 75204
t 314.302.6864
www.modusarchitecture.com
FOR INFORMATION
PURPOSES ONLY. NOT TO
BE USED IN ANY CAPACITY
FOR BIDDING, PERMITTING,
OR CONSTRUCTION
REVISIONS:
SHEET NAME
ISSUE DATE:
16
2
5
L
A
N
C
A
S
T
E
R
D
R
I
V
E
GR
A
P
E
V
I
N
E
,
T
E
X
A
S
7
6
0
5
1
G004
ACCESSIBILITY
STANDARDS
PE
R
M
I
T
S
E
T
CO
O
K
C
H
I
L
D
R
E
N
'
S
12/19/2024
1/4" = 1'-0"14 ADA DETAIL SIGNAGE
3" = 1'-0"11 STAIRWAY IDENTIFICATION SIGN
3" = 1'-0"13 TACTILE EXIT SIGN
3" = 1'-0"12 STAIRWAY FLOOR LEVEL SIGN
1/2" = 1'-0"7 WC ELEVATION
1/2" = 1'-0"8 WC SECTION
1/2" = 1'-0"9 ACCESSIBLE TOILET STALL
1/2" = 1'-0"10 ACCESSIBLE CLEAR FLOOR SPACE
1/2" = 1'-0"5 TOILET ACCESSORIES
1/2" = 1'-0"6 SINK IN COUNTER CLEARANCES
1/2" = 1'-0"1 SWITCH @ DOOR
1/2" = 1'-0"2 FE CABINET
1 1/2" = 1'-0"3 HANDRAIL CLEARANCES
3/4" = 1'-0"4 STANDARD BLOCKING DETAILS
APPLICABLE CODES:
APPLICABLE BUILDING CODE:
APPLICABLE PLUMBING CODE:
APPLICABLE MECHANICAL CODE:
APPLICABLE ELECTRICAL CODE:
APPLICABLE FIRE CODE:
APPLICABLE FIRE / LIFE SAFETY CODE:
APPLICABLE ENERGY CODE:
APPLICABLE ACCESSIBILITY CODE:
2021 INTERNATIONAL BUILDING CODE - W/ LOCAL AMENDMENTS
2021 INTERNATIONAL PLUMBING CODE - W/ LOCAL AMENDMENTS
2021 INTERNATIONAL MECHANICAL CODE - W/ LOCAL AMENDMENTS
2020 NATIONAL ELECTRICAL CODE - W/ LOCAL AMENDMENTS
2021 INTERNATIONAL FIRE CODE - W/ LOCAL AMENDMENTS (INCLUDING REFERENCED
NFPA CODE)
2015 INTERNATIONAL ENERGY CONSERVATION CODE
2012 TEXAS ACCESSIBILITY CODE
CODE INFORMATION:
PROJECT: COOK CHILDREN'S CLINIC
LOCATION: GRAPEVINE, TX
ARCHITECT:
MODUS ARCHITECTURE, PLLC
4040 N CENTRAL EXPY, SUITE 720
DALLAS, TX 75204
ISSUE (TABLE/ SECTION/ REFERENCE):
BUILDING/PROJECT USE (IBC SECTION 308):
CONSTRUCTION TYPE (IBC TABLE 503 & 601):
OCCUPANCY CLASSIFICATION (IBC SECTION 304.1):
REQUIREMENT:
BUSINESS
TYPE V-B (ASSUMED), SPRINKLERED
B - BUSINESS (AMBULATORY AND OUTPATIENT CASE < 24 HOURS)
FIRE RESISTIVE REQUIREMENTS
(TABLE/ SECTION/ REFERENCE):
EXTERIOR BEARING WALLS (IBC TABLE 601)
EXTERIOR OPENINGS (IBC TABLE 705.8)
EXTERIOR NON-BEARING WALLS (IBC TABLE 602)
INTERIOR BEARING WALLS (IBC TABLE 601)
INTERIOR NON-BEARING WALLS (IBC TABLE 601)
STRUCTURAL FRAME (IBC TABLE 601)
STRUCTURAL FRAME FOR SUPPORTING SHAFTS (IBC TABLE 701.3.10)
FLOOR CONSTRUCTION (IBC TABLE 601)
ROOF (TABLE 601)
CORRIDORS (IBC TABLE 1018.1)
SHAFT WALLS (IBC TABLE 708.4)
INTERIOR EXIT STAIRWAYS (IBC SECTION 1022.2)
OCCUPANCY SEPARATION B/E (IBC TABLE 508.4)
REQUIREMENTS
CONSTRUCTION TYPE VB:
0 HRS
NO LIMIT
0 HRS
0 HRS
0 HRS
0 HRS
0 HRS
0 HRS
0 HRS
0 HRS
0 HRS
0 HRS
0 HRS
1
TENANT A: CODE INFORMATION
REQUIREMENT
FLOOR AREA (GROSS)
OCCUPANT LOAD
EXITS REQUIRED
EXITS PROVIDED
EGRESS WIDTH REQUIRED
EGRESS WIDTH PROVIDED
EXIT TRAVEL DISTANCE
MAX EXIT TRAVEL DISTANCE
(IBC 1017.2)
6,656 SF
247 SF STORAGE (300 OLF) = 1 OCCUPANTS
5,709 SF BUSINESS (150 GROSS) = 43 OCCUPANTS
700 SF WAITING (15 GROSS) = 47 OCCUPANTS
TOTAL = 91 OCCUPANTS
2
3
91*0.2 (SPRINKLED) = 18.2" WIDTH (32" MIN.)
2 DOORS AT 32" = 64" PROVIDED
REFER TO TABLES ON G110
300' -0"
PLUMBING FIXTURE REQUIREMENTS
2021 INTERNATIONAL PLUMBING CODE: TABLE 403.1
PLUMBING FIXTURES
WATER CLOSETS:
LAVATORIES:
DRINKING FOUNTAINS:
SERVICE SINK:
REQUIRED
3
3
1
1
ISSUE
PROVIDED
4
4
1
1
F.E.C.
FIRE EXTINGUISHER CABINET
1 HOUR RATED WALL
EXIT SIGN
AED AED CABINET
LIFE SAFETY
LEGEND
OCCUPANCY
LEGEND
BUSINESS
ACCESSORY STORAGE
WAITING AREA
1
A
B
C
5709 SF
BUSINESS
700 SF
WAITING AREA
119 SF
STORAGE
40 SF
STORAGE
N.I.C.
N.I.C.
F.E.C.
F.E.C.
EXAM 12EXAM 13EXAM 14 EXAM 11 EXAM 10 EXAM 09 EXAM 08
IT/ELEC
EXAM 07
EXAM 06
EXAM 03EXAM 02EXAM 01
STAFF TLT BREAKROOM
MA
STATION
EXAM 05
EXAM 04
EXAM 15 NURSING
WAITING
LAB
RECEPTION
SHARED
OFFICEVITALS
TLT
TLT
88 SF
STORAGE
TLT
RISER
ROOM
EVSAE
D
B
AC
F.
E
.
C
.
F.
E
.
C
.
CURRENTLY UNOCCUPIED
FUTURE TYPE "B" OCCUPANCY
CURRENTLY UNOCCUPIED
FUTURE TYPE "B" OCCUPANCY
1
1
1
1
1. THIS PLAN IS PROVIDED FOR THE CONVENIENCE OF
THE BUILDING OFFICIAL AND FIRE MARSHAL. IT
DOCUMENTS THE MAJOR LIFE SAFETY FEATURES OF
THE PROJECT
2. REFERENCE MECHANICAL DRAWINGS FOR LOCATION
OF FIRE DAMPER REQUIREMENTS IN DUCTWORK
3. REFERENCE ELECTRICAL DRAWINGS FOR LOCATION
OF FIRE ALARM SYSTEM
4. REFERENCE REFLECTED CEILING PLANS AND
ELECTRICAL DRAWINGS FOR EXIT LIGHT LOCATIONS
5. REFERENCE PLUMBING DRAWINGS FOR AUTOMATIC
SPRINKLER SYSTEMS
6. SQUARE FOOTAGE INDICATED ON THE LIFE SAFETY
PLAN RELATES TO OCCUPANT LOAD ONLY AND SHALL
NOT BE USED FOR ANY OTHER PURPOSE
7. REFER TO G001 FOR CODE COMPLIANCE GENERAL
NOTES
8. CORRIDORS NOT CONSIDERED IN OCCUPANCY
CALCULATIONS
9. TACTILE EXIT SIGNS ARE TO BE PROVIDED ADJACENT
TO EACH DOOR TO AN EXIT STAIRWAY OR RAMP, AN
EXIT PASSAGEWAY AND THE EXIT DISCHARGE
10. EXISTING WALLS SHOWN WITH NEW LIFE SAFETY
RATINGS ARE TO BE UPGRADED TO THE NEW RATING.
THE UPGRADING INCLUDES PROTECTING ALL
OPENINGS IN THE PARTITION
11. DOORS IN CORRIDOR PARTITIONS SHALL BE
INSTALLED TO RESIST THE PASSAGE OF SMOKE
UNLESS NOTED OTHERWISE
12. VERIFY THAT ALL EXISTING DOORS IN RATED WALLS
ARE LABELED WITH THE APPROPRIATE MARK
13. VERIFY THAT ALL EXISTING WALLS THAT ARE
LABELED AS FIRE RATED OR SMOKE TIGHT MEET THE
REQUIREMENTS OF THE LABELING
GENERAL NOTES
LIFE SAFETY
SHEET NUMBER
4040 N CENTRAL EXPY,
SUITE 720
DALLAS, TEXAS 75204
t 314.302.6864
www.modusarchitecture.com
FOR INFORMATION
PURPOSES ONLY. NOT TO
BE USED IN ANY CAPACITY
FOR BIDDING, PERMITTING,
OR CONSTRUCTION
REVISIONS:
SHEET NAME
ISSUE DATE:
16
2
5
L
A
N
C
A
S
T
E
R
D
R
I
V
E
GR
A
P
E
V
I
N
E
,
T
E
X
A
S
7
6
0
5
1
G110
OVERALL LIFE
SAFETY PLAN
PE
R
M
I
T
S
E
T
CO
O
K
C
H
I
L
D
R
E
N
'
S
12/19/2024
EGRESS (MAXIMUM TRAVEL DISTANCE)
TYPE DISTANCE
EGRESS PATH A 109' - 1"
EGRESS PATH B 123' - 9"
EGRESS PATH C 76' - 11"
EGRESS (COMMON PATH OF TRAVEL)
TYPE DISTANCE
EGRESS PATH A 77' - 4"
EGRESS PATH B 60' - 3"
EGRESS PATH C 42' - 11"
PLAN
NORTH
TRUE
NORTH
3/16" = 1'-0"1 LIFE SAFETY PLAN
1 ADDENDUM 01 02.17.25
1
FOR INFORMATION
PURPOSES ONLY. NOT TO
BE USED IN ANY CAPACITY
FOR BIDDING, PERMITTING,
OR CONSTRUCTION
SECTION 012100 ALLOWANCES
PART 1 GENERAL
1. SECTION INCLUDES
A. Cash allowances.
B. Contingency allowance.
C. Inspecting and testing allowances.
D. Payment and modification procedures relating to allowances.
1. CASH ALLOWANCES
A. Costs Included in Cash Allowances: Cost of product to Contractor or subcontractor, less
applicable trade discounts, less cost of delivery to site, less applicable taxes.
B. Costs Not Included in Cash Allowances: Product delivery to site and handling at the site,
including unloading, uncrating, and storage; protection of products from elements and from
damage; and labor for installation and finishing.
C. Architect Responsibilities:
1. Consult with Contractor for consideration and selection of products, suppliers, and
installers.
2. Select products in consultation with Owner and transmit decision to Contractor.
3. Prepare Change Order.
D. Contractor Responsibilities:
1. Assist Architect in selection of products, suppliers, and installers.
2. Obtain proposals from suppliers and installers and offer recommendations.
3. On notification of which products have been selected, execute purchase agreement with
designated supplier and installer.
4. Arrange for and process shop drawings, product data, and samples. Arrange for delivery.
5. Promptly inspect products upon delivery for completeness, damage, and defects. Submit
claims for transportation damage.
E. Differences in costs will be adjusted by Change Order.
2. CONTINGENCY ALLOWANCE
A. Contractor's costs for products, delivery, installation, labor, insurance, payroll, taxes, bonding,
equipment rental, overhead and profit will be included in Change Orders authorizing
expenditure of funds from this Contingency Allowance.
B. Funds will be drawn from the Contingency Allowance only by Change Order.
C. At closeout of Contract, funds remaining in Contingency Allowance will be credited to Owner
by Change Order.
3. INSPECTING AND TESTING ALLOWANCES
A. Costs Included in Inspecting and Testing Allowances: Cost of engaging an inspecting or testing
agency; execution of inspecting and tests; and reporting results.
B. Costs Not Included in the Inspecting and Testing Allowances:
1. Costs of incidental labor and facilities required to assist inspecting or testing agency.
2. Costs of testing services used by Contractor separate from Contract Document
requirements.
3. Costs of retesting upon failure of previous tests as determined by Architect.
C. Payment Procedures:
1. Submit one copy of the inspecting or testing firm's invoice with next application for
payment.
2. Pay invoice on approval by Architect.
D. Differences in cost will be adjusted by Change Order.
SECTION 008000 SUPPLEMENTARY CONDITIONS
1. SUPPLEMENTS
A. The following supplements modify, change, delete from or add to the "General Conditions of the
Contract for Construction", AIA Document A201, Seventeenth Edition, 2017. Where any Article of
the General Conditions is modified or any Paragraph, Subparagraph or Clause thereof is modified
or deleted by these supplements, the unaltered provision of the Article, Paragraph, Subparagraph
or Clause shall remain in effect.
2. REFERENCE TO DIVISION 01
A. With regard to provisions of General Conditions related to project administrative or work-related
requirements of the Contract, some of those paragraphs are modified or deleted from General
Conditions, and are specified in Division 01, "General Requirements" of the Specifications.
ARTICLE 1 GENERAL PROVISIONS
Add the following new paragraphs:
1.1.9 MISCELLANEOUS DEFINITIONS
1.1.9.1 The term "Product" as used in these Contract Documents includes materials, systems, and
equipment.
1.1.9.2 The term "provide" as used in this Project Manual means to furnish and install.
1.2 CORRELATION AND INTENT OF THE CONTRACT DOCUMENTS
Add the following new subparagraphs:
1.2.4 The inter-relation of the Project Manual, the Drawings and the schedules is as follows: The Project
Manual determines the quality, nature and setting of the several materials; the Drawings establish the
quantities, dimensions and details; and the schedules give the location. The documents are to be
considered as one and whatever is called for by any one shall be as binding as if called for by all.
1.2.5 Should the drawings disagree in themselves, or with the Project Manual, or if proprietary
information disagrees with performance requirements in either the Drawings or the Project Manual, the
better quality or greater quantity of the Work or materials shall be estimated upon, and unless otherwise
ordered by the Architect in writing, shall be performed or furnished. Should discrepancies or doubt occur, do
not proceed with the Work or estimate without clarification from the Architect. Contractor shall request
clarification in sufficient time to avoid delays and/or any adjustments in the contract sum.
ARTICLE 3 CONTRACTOR
3.2 REVIEW OF CONTRACT DOCUMENTS AND FIELD CONDITIONS BY CONTRACTOR
Add following sentences to subparagraph 3.2.2:
3.2.2.1 If a dimensional discrepancy exists, Contractor shall take field measurements required for proper
fabrication and installation of work. Upon commencement of any item of work, Contractor shall be
responsible for dimensions related to such item of Work and shall make any corrections necessary to make
work properly fit at no additional cost to Owner.
3.2.2.2 Before ordering any material or doing any work, Contractor shall verify dimensions and check
conditions in order to assure himself that they properly reflect those on the Drawings. Any inconsistency
shall be brought to attention of the Architect. In the event
that discrepancies occur between ordered material and actual conditions, of which Architect was not
notified beforehand, costs to correct such discrepancies shall be borne by Contractor.
3.3 SUPERVISION AND CONSTRUCTION PROCEDURES
Supplement as provided in Division 01.
3.4 LABOR AND MATERIALS
Add the following new paragraph:
3.4.4 Within 15 days after the Contract has been executed, the Owner and the Architect will consider a
formal request for the substitution of products in place of those specified only under the conditions set forth
in the General Requirements of the Specifications, Division 01. Refer to Division 01 for supplemental
information.
3.5 WARRANTY
Supplement as provided in Division 01.
3.8 ALLOWANCES
Supplement as provided in Division 01.
3.10 CONTRACTOR'S CONSTRUCTION PROGRESS SCHEDULES
Supplement as provided in Division 01.
3.11 DOCUMENTS AND SAMPLES AT THE SITE
Supplement as provided in Division 01.
3.12 SHOP DRAWINGS, PRODUCT DATA AND SAMPLES
Supplement as provided in Division 01, Section 011000, Summary.
3.13 USE OF SITE
Supplement as provided in Division 01.
3.14 CUTTING AND PATCHING
Supplement as provided in Division 01.
3.15 CLEANING UP
Supplement as provided in Division 01.
ARTICLE 6 CONSTRUCTION BY OWNER OR BY SEPARATE CONTRACTORS
Add the following new paragraph
6.1.5 Coordinated construction work under this Contract includes, but is not limited to, providing
concealed blocking as noted for attachment of separate contract items in locations necessary for the actual
items to be installed. Provide proper dimensional coordination of separate contract supplied items for
general construction work and trim that is to meet and/or adjoin Furniture, Fixtures, Equipment and
Accessories.
6.1.6 It is a requirement of the Contractor’s work schedule to provide the cooperation, coordination and
exchange of information necessary for a timely execution of separate contract work.
ARTICLE 7 CHANGES IN THE WORK
7.1 GENERAL
Supplement as provided in Division1. Add the following new paragraphs:
7.1.4 Except as provided in this article, no oral statement, or direction of Architect or Owner shall be
treated as a Change Order or entitle Contractor to an adjustment to the Contract Sum or the Contract Time.
7.1.5 Unit prices shall be inclusive of all costs including mark-up for overhead and profit and shall be
applied to units of measure as defined in the Contract Documents for each category of Work. Contractor
shall identify overhead and profit amounts for each unit price.
7.1.6 The allowance for the combined overhead and profit included in the total cost to the Owner shall be
based on the following schedule:
7.1.6.1 For the Contractor, for Work performed by the Contractor’s own forces, 15 percent of the cost.
7.1.6.2 For the Contractor, for Work performed by the Contractor’s Subcontractor, 10 percent of the
amount due the Subcontractor.
7.1.6.3 For each Subcontractor or Sub-subcontractor involved, for Work performed by that Subcontractor’s
or Sub-subcontractor’s own forces, 15 percent of the cost.
7.1.6.4 For each Subcontractor, for Work performed by the Subcontractor’s Sub-subcontractors, 10
percent of the amount due the Sub-subcontractor.
7.1.6.5 In order to facilitate checking of quotations for extras or credits, all proposals, except those so
minor that their propriety can be seen by inspection, shall be accompanied by a complete itemization of
costs including labor, materials and Subcontracts. Labor and materials shall be itemized in the manner
prescribed above. Where major cost items are Subcontracts, they shall be itemized also. In no case will a
change involving over
$2,000.00 be approved without such itemization.
ARTICLE 8 - TIME
8.3 DELAYS AND EXTENSIONS OF TIME
Add the following new paragraphs
8.3.4 Apart from extension of time, no payment or claim for damages shall be made to Contractor as
compensation for damages for any ordinary delays or hindrances from any cause whatsoever in the
progress of the Work, notwithstanding whether such delay be avoidable or unavoidable.
8.3.5 In order to claim an inclement weather delay day, Contractor must:
8.3.5.1 Document, in writing, that the weather on the particular day was of such nature (rain, wind, snow,
ice, and subsequent resultant effects) that it significantly impacted its ability to make progress on critical
path work items. Utilize NOAA weather data from a nearby site as the back-up for all claims.
8.3.5.2 Submit such delay claims on a weekly basis, not more than 7 days following the last day of
occurrence.
8.3.5.3 Summarize the number of days claimed for the entire month accompanying each month’s
application for payment.
ARTICLE 9 PAYMENTS AND COMPLETION
9.2 SCHEDULE OF VALUES
Supplement as provided in Division 01.
9.3 APPLICATIONS FOR PAYMENT Supplement as provided in Division 01. Add the following new
subparagraph:
9.3.4 Unless otherwise stated in the Owner-Contractor Agreement, the Owner will retain, until Final
Payment, 10 percent of the amount due the Contractor on account of progress payments, payable 30 days
after Substantial Completion and/or satisfactory ev idence to the owner that all payments, bills, and claims
have been paid.
Add following Sub-subparagraphs:
9.3.4 Monthly Applications for Payment shall include waivers of liens for all work included in previous
months' application for payment. Waiver of Liens for subcontractors and materialmen shall be total amount
paid prior to previous months' application for
payment.
9.5 DECISIONS TO WITHHOLD CERTIFICATION
Add following Sub-subparagraph 9.5.1.8 to Subparagraph 9.5.1:
9.5.1.8 Failure to submit written plan indicating action by Contractor to regain time schedule for completion
of Work within Contract Time.
9.5.1.9 Failure to keep record documents current.
9.8 SUBSTANTIAL COMPLETION
Supplement as provided in Division 01.
9.10 FINAL COMPLETION AND FINAL PAYMENT
Add the following new paragraph
9.10.2.1 In addition to the items listed in 9.10.2, the Contractor shall deliver 2 hard copies and 2 electronic
copies (PDF format on thumb drive) sets of the following items to the Owner before final payment will be
made:
1. Other close-out submittals as specified in Division 01.
2. Project record documents as specified in Division 01.
3. Operations and maintenance data as specified in Division 01.
4. All warranties as required on specific products or portions of the Work, in format outlined in Division 01.
5. Spare parts, overages, and maintenance materials as outlined in Division 01 and described in the
various technical sections.
6. Certificates of occupancy.
7. Copies of all inspection tags from authorities having jurisdiction.
8. Executed Certificate of Substantial Completion.
ARTICLE 11 INSURANCE AND BONDS
Refer to Owner-Contractor Agreement
ARTICLE 13 MISCELLANEOUS PROVISIONS
13.5 TESTS AND INSPECTIONS
Supplement as provided in Division 01, Section 014000, Quality Requirements.
SECTION 007000 GENERAL CONDITIONS
1. DRAWINGS AND GENERAL PROVISIONS OF THE CONTRACT, INCLUDING GENERAL AND
SUPPLEMENTARY CONDITIONS AND DIVISION 01 SPECIFICATION SECTIONS, APPLY TO
THIS SECTION.
2. GENERAL CONDITIONS
A. The "General Conditions of the Contract for Construction", AIA Document A201, 2017 edition,
Articles 1 through 15 inclusive, is a part of this Contract, and is available for review from the
Architect. The General Conditions and all modifications listed in Section 008000 shall apply to
all various subcontracts and sub-subcontractors.
B. Refer to Document 008000 for Supplementary Conditions.
C. Should the general conditions or supplementary conditions be in conflict with the Owner
Contractor agreement, the Owner-Contractor agreement shall govern.
SECTION 012200 UNIT PRICES
PART 1 GENERAL
1. SECTION INCLUDES
A. List of unit prices, for use in preparing Bids.
B. Measurement and payment criteria applicable to Work performed under a unit price payment
method.
C. Defect assessment and non-payment for rejected work.
2. COSTS INCLUDED
A. Unit Prices included on the Bid Form shall include full compensation for all required labor,
products, tools, equipment, plant, transportation, services and incidentals; erection, application
or installation of an item of the Work; overhead and profit.
3. UNIT QUANTITIES SPECIFIED
A. Quantities indicated in the Bid Form are for bidding and contract purposes only. Quantities and
measurements of actual Work will determine the payment amount.
4. MEASUREMENT OF QUANTITIES
A. Measurement methods delineated in the individual specification sections complement the
criteria of this section. In the event of conflict, the requirements of the individual specification
section govern.
B. Take all measurements and compute quantities. Measurements and quantities will be verified
by Architect.
C. Assist by providing necessary equipment, workers, and survey personnel as required.
D. Measurement Devices:
1. Weigh Scales: Inspected, tested and certified by the applicable state Weights and
Measures department within the past year.
2. Platform Scales: Of sufficient size and capacity to accommodate the conveying vehicle.
3. Metering Devices: Inspected, tested and certified by the applicable state department within
the past year.
E. Measurement by Weight: Concrete reinforcing steel, rolled or formed steel or other metal
shapes will be measured by handbook weights. Welded assemblies will be measured by
handbook or scale weight.
F. Measurement by Volume: Measured by cubic dimension using mean length, width and height
or thickness.
G. Measurement by Area: Measured by square dimension using mean length and width or radius.
H. Linear Measurement: Measured by linear dimension, at the item centerline or mean chord.
I. Stipulated Price Measurement: Items measured by weight, volume, area, or linear means or
combination, as appropriate, as a completed item or unit of the Work.
J. Perform surveys required to determine quantities, including control surveys to establish
measurement reference lines. Notify Architect prior to starting work.
K. Contractor's Engineer Responsibilities: Sign surveyor's field notes or keep duplicate field
notes, calculate and certify quantities for payment purposes.
5. PAYMENT
A. Payment for Work governed by unit prices will be made on the basis of the actual
measurements and quantities of Work that is incorporated in or made necessary by the Work
and accepted by the Architect, multiplied by the unit price.
B. Payment will not be made for any of the following:
1. Products wasted or disposed of in a manner that is not acceptable.
2. Products determined as unacceptable before or after placement.
3. Products not completely unloaded from the transporting vehicle.
4. Products placed beyond the lines and levels of the required Work.
5. Products remaining on hand after completion of the Work.
6. Loading, hauling, and disposing of rejected Products.
6. DEFECT ASSESSMENT
A. Replace Work, or portions of the Work, not complying with specified requirements.
B. If, in the opinion of Architect, it is not practical to remove and replace the Work, Architect will
direct one of the following remedies:
1. The defective Work may remain, but the unit price will be adjusted to a new unit price at
the discretion of Architect.
2. The defective Work will be partially repaired to the instructions of the Architect, and the
unit price will be adjusted to a new unit price at the discretion of Architect.
C. The individual specification sections may modify these options or may identify a specific
formula or percentage price reduction.
D. The authority of Architect to assess the defect and identify payment adjustment is final.
C. Test Reports: After each test/inspection, promptly submit two copies of report to Architect and
to Contractor.
1. Test report submittals are for Architect's knowledge as contract administrator for the
limited purpose of assessing compliance with information given and the design concept
expressed in the contract documents, or for Owner's information.
D. Certificates: When specified in individual specification sections, submit certification by the
manufacturer and Contractor or installation/application subcontractor to Architect, in quantities
specified for Product Data.
1. Indicate material or product complies with or exceeds specified requirements. Submit
supporting reference data, affidavits, and certifications as appropriate.
2. Certificates may be recent or previous test results on material or product, but must be
acceptable to Architect.
E. Manufacturer's Instructions: When specified in individual specification sections, submit printed
instructions for delivery, storage, assembly, installation, start-up, adjusting, and finishing, for
the Owner's information. Indicate special procedures, perimeter conditions requiring special
attention, and special environmental criteria required for application or installation.
F. Manufacturer's Field Reports: Submit reports for Architect's benefit as contract administrator or
for Owner.
1. Submit for information for the limited purpose of assessing compliance with information
given and the design concept expressed in the contract documents.
G. Erection Drawings: Submit drawings for Architect's benefit as contract administrator or for
Owner.
1. Submit for information for the limited purpose of assessing compliance with information
given and the design concept expressed in the contract documents.
1.4 REFERENCES AND STANDARDS
A. For products and workmanship specified by reference to a document or documents not
included in the Project Manual, also referred to as reference standards, comply with
requirements of the standard, except when more rigid requirements are specified or are
required by applicable codes.
B. Comply with reference standard of date of issue current on date of Contract Documents,
except where a specific date is established by applicable code.
C. Obtain copies of standards where required by product specification sections.
D. Maintain copy at project site during submittals, planning, and progress of the specific work,
until Substantial Completion.
E. Should specified reference standards conflict with Contract Documents, request clarification
from Architect before proceeding.
F. Neither the contractual relationships, duties, or responsibilities of the parties in Contract nor
those of Architect shall be altered from the Contract Documents by mention or inference otherwise
in any reference document.
1.5 TESTING AND INSPECTION AGENCIES AND SERVICES
A. Contractor shall employ and pay for services of an independent testing agency to perform
other specified testing.
B. Employment of agency in no way relieves Contractor of obligation to perform Work in
accordance with requirements of Contract Documents.
PART 3 EXECUTION
3.1 CONTROL OF INSTALLATION
A. Monitor quality control over suppliers, manufacturers, products, services, site conditions, and
workmanship, to produce work of specified quality.
B. Comply with manufacturers' instructions, including each step in sequence.
C. Should manufacturers' instructions conflict with Contract Documents, request clarification from
Architect before proceeding.
D. Comply with specified standards as minimum quality for the work except where more stringent
tolerances, codes, or specified requirements indicate higher standards or more precise
workmanship.
E. Have work performed by persons qualified to produce required and specified quality.
F. Verify that field measurements are as indicated on shop drawings or as instructed by the
manufacturer.
G. Secure products in place with positive anchorage devices designed and sized to withstand
stresses, vibration, physical distortion, and disfigurement.
3.2 MOCK-UPS
A. Apply finish materials to demonstrate the proposed range of materials, colors, and
workmanship.
B. Tests shall be performed under provisions identified in this section and identified in the
respective product specification sections.
C. Assemble and erect specified items with specified attachment and anchorage devices,
flashings, seals, and finishes.
D. Accepted mock-ups shall be a comparison standard for the remaining Work.
E. Where mock-up has been accepted by Architect and is specified in product specification
sections to be removed, protect mock-up throughout construction, remove mock-up and clear
area when directed to do so by Architect.
3.3 TOLERANCES
A. Monitor fabrication and installation tolerance control of products to produce acceptable Work.
Do not permit tolerances to accumulate.
B. Comply with manufacturers' tolerances. Should manufacturers' tolerances conflict with
Contract Documents, request clarification from Architect before proceeding.
C. Adjust products to appropriate dimensions; position before securing products in place.
3.4 TESTING AND INSPECTION
A. See individual specification sections for testing and inspection required.
B. Testing Agency Duties:
1. Provide qualified personnel at site. Cooperate with Architect and Contractor in
performance of services.
2. Perform specified sampling and testing of products in accordance with specified
standards.
3. Ascertain compliance of materials and mixes with requirements of Contract Documents.
4. Promptly notify Architect and Contractor of observed irregularities or non-compliance of
Work or products.
5. Perform additional tests and inspections required by Architect.
6. Submit reports of all tests/inspections specified.
C. Limits on Testing/Inspection Agency Authority:
1. Agency may not release, revoke, alter, or enlarge on requirements of Contract
Documents.
2. Agency may not approve or accept any portion of the Work.
3. Agency may not assume any duties of Contractor.
4. Agency has no authority to stop the Work.
D. Contractor Responsibilities:
1. Deliver to agency at designated location, adequate samples of materials proposed to be
used that require testing, along with proposed mix designs.
2. Cooperate with laboratory personnel, and provide access to the Work and to
manufacturers' facilities.
3. Provide incidental labor and facilities:
a. To provide access to Work to be tested/inspected.
b. To obtain and handle samples at the site or at source of Products to be
tested/inspected.
c. To facilitate tests/inspections.
d. To provide storage and curing of test samples.
4. Notify Architect and laboratory 24 hours prior to expected time for operations requiring
testing/inspection services.
5. Employ services of an independent qualified testing laboratory and pay for additional
samples, tests, and inspections required by Contractor beyond specified requirements.
6. Arrange with Owner's agency and pay for additional samples, tests, and inspections
required by Contractor beyond specified requirements.
E. Re-testing required because of non-compliance with specified requirements shall be performed
by the same agency on instructions by Architect.
F. Re-testing required because of non-compliance with specified requirements shall be paid for
by Contractor.
3.5 MANUFACTURERS' FIELD SERVICES
A. When specified in individual specification sections, require material or product suppliers or
manufacturers to provide qualified staff personnel to observe site conditions, conditions of
surfaces and installation, quality of workmanship, start-up of equipment, test, adjust, and
balance equipment as applicable, and to initiate instructions when necessary.
B. Report observations and site decisions or instructions given to applicators or installers that are
supplemental or contrary to manufacturers' written instructions.
3.6 DEFECT ASSESSMENT
A. Replace Work or portions of the Work not complying with specified requirements.
B. If, in the opinion of Architect, it is not practical to remove and replace the work, Architect will
direct an appropriate remedy or adjust payment.
SECTION 014000 - QUALITY REQUIREMENTS
PART 1 GENERAL
1.1 SECTION INCLUDES
A. Submittals.
B. References and standards
C. Testing and inspection agencies and services.
D. Control of installation.
E. Mock-ups.
F. Tolerances.
G. Manufacturers' field services.
H. Defect Assessment.
1.2 RELATED REQUIREMENTS
A. Section 014216 - Definitions.
1.3 SUBMITTALS
A. See Section 013000 - Administrative Requirements, for submittal procedures.
B. Testing Agency Qualifications:
1. Prior to start of Work, submit agency name, address, and telephone number, and names
of full time registered Engineer and responsible officer.
2. Submit copy of report of laboratory facilities inspection made by NIST Construction
Materials Reference Laboratory during most recent inspection, with memorandum of
remedies of any deficiencies reported by the inspection.
C. Design Data: Submit for Architect's knowledge as contract administrator for the limited purpose
of assessing compliance with information given and the design concept expressed in the
contract documents, or for Owner's information.
SECTION 013000 - ADMINISTRATIVE REQUIREMENTS
PART 1 GENERAL
1.1 SECTION INCLUDES
A. Electronic document submittal service.
B. Preconstruction meeting.
C. Progress meetings.
D. Construction progress schedule.
E. Progress photographs.
F. Submittals for review, information, and project closeout.
G. Submittal procedures.
PART 3 EXECUTION
3.1 PRECONSTRUCTION MEETING
A. Owner will schedule a meeting after Notice of Award.
B. Attendance Required:
1. Owner.
2. Architect.
3. Contractor.
C. Agenda:
1. Execution of Owner-Contractor Agreement.
2. Submission of executed bonds and insurance certificates.
3. Distribution of Contract Documents.
4. Submission of list of subcontractors, list of products, schedule of values, and progress
schedule.
5. Designation of personnel representing the parties to Contract and Architect.
6. Procedures and processing of field decisions, submittals, substitutions, applications for
payments, proposal request, Change Orders, and Contract closeout procedures.
7. Scheduling.
D. Record minutes and distribute copies within two days after meeting to participants, with two
copies to Architect, Owner, participants, and those affected by decisions made.
3.2 PROGRESS MEETINGS
A. Schedule and administer meetings throughout progress of the work at maximum bi-monthly
intervals.
B. Make arrangements for meetings, prepare agenda with copies for participants, preside at
meetings.
C. Attendance Required:
1. Contractor.
2. Owner.
3. Architect.
4. Contractor's superintendent.
5. Major subcontractors.
D. Agenda:
1. Review minutes of previous meetings.
2. Review of work progress.
3. Field observations, problems, and decisions.
4. Identification of problems that impede, or will impede, planned progress.
5. Review of submittals schedule and status of submittals.
6. Review of off-site fabrication and delivery schedules.
7. Maintenance of progress schedule.
8. Corrective measures to regain projected schedules.
9. Planned progress during succeeding work period.
10. Coordination of projected progress.
11. Maintenance of quality and work standards.
12. Effect of proposed changes on progress schedule and coordination.
13. Other business relating to work.
E. Record minutes and distribute copies within two days after meeting to participants, with two
copies to Architect, Owner, participants, and those affected by decisions made.
3.3 CONSTRUCTION PROGRESS SCHEDULE
A. Within 10 days after date of the Agreement, submit preliminary schedule defining planned
operations for the first 60 days of work, with a general outline for remainder of work.
B. If preliminary schedule requires revision after review, submit revised schedule within 10 days.
C. Within 20 days after review of preliminary schedule, submit draft of proposed complete
schedule for review.
1. Include written certification that major contractors have reviewed and accepted proposed
schedule.
D. Within 10 days after joint review, submit complete schedule.
E. Submit updated schedule with each Application for Payment.
3.4 PROGRESS PHOTOGRAPHS
A. Submit photographs with each application for payment, taken not more than 3 days prior to
submission of application for payment.
B. Photography Type: Digital; electronic files.
C. In addition to periodic, recurring views, take photographs of each of the following events:
1. Completion of site clearing.
2. Excavations in progress.
3. Foundations in progress and upon completion.
4. Structural framing in progress and upon completion.
5. Enclosure of building, upon completion.
6. Final completion, minimum of ten (10) photos.
D. Views:
1. Provide non-aerial photographs from four cardinal views at each specified time, until date
of Substantial Completion.
2. Consult with Architect for instructions on views required.
3. Provide factual presentation.
4. Provide correct exposure and focus, high resolution and sharpness, maximum depth of
field, and minimum distortion.
E. Digital Photographs: 24 bit color, minimum resolution of 1024 by 768, in JPG format; provide
files unaltered by photo editing software.
1. Delivery Medium: Via email.
2. File Naming: Include project identification, date and time of view, and view identification.
3. PDF File: Assemble all photos into printable pages in PDF format, with 2 to 3 photos per
page, each photo labeled with file name; one PDF file per submittal.
4. Hard Copy: Printed hardcopy (grayscale) of PDF file and point of view sketch.
3.5 SUBMITTALS FOR REVIEW
A. When the following are specified in individual sections, submit them for review:
1. Product data.
2. Shop drawings.
3. Samples for selection.
4. Samples for verification.
B. Submit to Architect for review for the limited purpose of checking for compliance with
information given and the design concept expressed in the contract documents.
C. Samples will be reviewed for aesthetic, color, or finish selection.
D. After review, provide copies and distribute in accordance with SUBMITTAL PROCEDURES
article below and for record documents purposes described in Section 017800 - Closeout
Submittals.
3.6 SUBMITTALS FOR INFORMATION
A. When the following are specified in individual sections, submit them for information:
1. Design data.
2. Certificates.
3. Test reports.
4. Inspection reports.
5. Manufacturer's instructions.
6. Manufacturer's field reports.
7. Other types indicated.
B. Submit for Architect's knowledge as contract administrator or for Owner.
3.7 SUBMITTALS FOR PROJECT CLOSEOUT
A. Submit Correction Punch List for Substantial Completion.
B. Submit Final Correction Punch List for Substantial Completion.
C. When the following are specified in individual sections, submit them at project closeout in
compliance with requirements of Section 017800 - Closeout Submittals:
1. Project record documents.
2. Operation and maintenance data.
3. Warranties.
4. Bonds.
5. Other types as indicated.
A. Submit for Owner's benefit during and after project completion.
3.8 SUBMITTAL PROCEDURES
A. General Requirements:
1. Transmit using approved form.
2. Sequentially identify each item. For revised submittals use original number and a
sequential numerical suffix.
3. Identify: Project; Contractor; subcontractor or supplier; pertinent drawing and detail
number; and specification section number and article/paragraph, as appropriate on each
copy.
4. Apply Contractor's stamp, signed or initialed certifying that review, approval, verification of
products required, field dimensions, adjacent construction work, and coordination of
information is in accordance with the requirements of the work and Contract Documents.
5. Schedule submittals to expedite the Project, and coordinate submission of related items.
6. Identify variations from Contract Documents and product or system limitations that may be
detrimental to successful performance of the completed work.
7. Provide space for Contractor and Architect review stamps.
8. When revised for resubmission, identify all changes made since previous submission.
9. Distribute reviewed submittals. Instruct parties to promptly report inability to comply with
requirements.
10. Submittals not requested will not be recognized or processed.
11. No extension of the Contract Time will be authorized due to Contractor's failure to provide
submittals in advance of the Work to permit processing or for submitting materials which
do not meet minimum standards as indicated in the Specifications.
12. Manufacturer's product data sheets listing multiple items must be clearly marked to
indicate the specific material or product submitted for use in the Work
2.3 MAINTENANCE MATERIALS
A. Furnish extra materials, spare parts, tools, and software of types and in quantities specified in
individual specification sections.
B. Deliver to Project site; obtain receipt prior to final payment.
PART 3 EXECUTION
3.1 SUBSTITUTION PROCEDURES
A. Comply with requirements specified in this section. Substitutions shall be considered for
comparable product(s) which have the indicated qualities or basis-of-design characteristics
related to type, function, dimension, in-service performance, physical properties, appearance,
and other characteristics that equal or exceed those of the specified product(s).
B. Architect will consider requests for substitutions only within 15 days after date of Agreement.
C. Substitutions will be considered when a product becomes unavailable through no fault of the
Contractor.
D. Document each request with complete data substantiating compliance of proposed substitution
with Contract Documents.
E. A request for substitution constitutes a representation that the submitter:
1. Has investigated proposed product and determined that it meets or exceeds the quality
level of the specified product.
2. Will provide the same warranty for the substitution as for the specified product.
3. Will coordinate installation and make changes to other Work that may be required for the
Work to be complete with no additional cost to Owner.
4. Waives claims for additional costs or time extension that may subsequently become
apparent.
A. Substitutions will not be considered at any time, when they are indicated or implied on shop
drawing or product data submittals, without separate written request on form hereto attached,
or when acceptance will require revision to the Contract Documents.
B. Substitution Submittal Procedure:
1. Submit one PDF of request for substitution for consideration. Limit each request to one
proposed substitution. Submit on form at the end of this Section.
2. Submit shop drawings, product data, and certified test results attesting to the proposed
product equivalence. Burden of proof is on proposer.
3. The Architect will notify Contractor in writing of decision to accept or reject request.
4. If substitution is not acceptable, Contractor will provide specified product (s).
3.2 TRANSPORTATION AND HANDLING
A. Package products for shipment in manner to prevent damage; for equipment, package to avoid
loss of factory calibration.
B. If special precautions are required, attach instructions prominently and legibly on outside of
packaging.
C. Coordinate schedule of product delivery to designated prepared areas in order to minimize site
storage time and potential damage to stored materials.
D. Transport and handle products in accordance with manufacturer's instructions.
E. Transport materials in covered trucks to prevent contamination of product and littering of
surrounding areas.
F. Promptly inspect shipments to ensure that products comply with requirements, quantities are
correct, and products are undamaged.
G. Provide equipment and personnel to handle products by methods to prevent soiling,
disfigurement, or damage, and to minimize handling.
H. Arrange for the return of packing materials, such as wood pallets, where economically feasible.
3.3 STORAGE AND PROTECTION
A. Designate receiving/storage areas for incoming products so that they are delivered according
to installation schedule and placed convenient to work area in order to minimize waste due to
excessive materials handling and misapplication. See Section 017419.
B. Store and protect products in accordance with manufacturers' instructions.
C. Store with seals and labels intact and legible.
D. Store sensitive products in weathertight, climate-controlled enclosures in an environment
favorable to product.
E. For exterior storage of fabricated products, place on sloped supports above ground.
F. Protect products from damage or deterioration due to construction operations, weather,
precipitation, humidity, temperature, sunlight and ultraviolet light, dirt, dust, and other
contaminants.
G. Comply with manufacturer's warranty conditions, if any.
H. Cover products subject to deterioration with impervious sheet covering. Provide ventilation to
prevent condensation and degradation of products.
I. Prevent contact with material that may cause corrosion, discoloration, or staining.
J. Provide equipment and personnel to store products by methods to prevent soiling,
disfigurement, or damage.
K. Arrange storage of products to permit access for inspection. Periodically inspect to verify
products are undamaged and are maintained in acceptable condition.
SECTION 016000 - PRODUCT REQUIREMENTS
PART 1 GENERAL
1.1 SECTION INCLUDES
A. General product requirements.
B. Transportation, handling, storage and protection.
C. Product option requirements.
D. Substitution limitations.
E. Maintenance materials, including extra materials, spare parts, tools, and software.
1.2 RELATED REQUIREMENTS
A. Section 017419 - Construction Waste Management and Disposal: Waste disposal
requirements potentially affecting product selection, packaging and substitutions.
1.3 SUBMITTALS
A. Proposed Products List: Submit list of major products proposed for use, with name of
manufacturer, trade name, and model number of each product.
1. Submit within 15 days after date of Agreement.
2. For products specified only by reference standards, list applicable reference standards.
B. Product Data Submittals: Submit manufacturer's standard published data. Mark each copy to
identify applicable products, models, options, and other data. Supplement manufacturers'
standard data to provide information specific to this Project.
C. Shop Drawing Submittals: Prepared specifically for this Project; indicate utility and electrical
characteristics, utility connection requirements, and location of utility outlets for service for
functional equipment and appliances.
D. Sample Submittals: Illustrate functional and aesthetic characteristics of the product, with
integral parts and attachment devices. Coordinate sample submittals for interfacing work.
1. For selection from standard finishes, submit samples of the full range of the
manufacturer's standard colors, textures, and patterns.
PART 2 PRODUCTS
2.1 NEW PRODUCTS
A. Provide new products unless specifically required or permitted by the Contract Documents.
B. Where other criteria are met, Contractor shall give preference to products that:
1. Are extracted, harvested, and/or manufactured closer to the location of the project.
2. Have longer documented life span under normal use.
3. Result in less construction waste. See Section 017419
4. Are made of vegetable materials that are rapidly renewable.
5. Are made of recycled materials.
2.2 PRODUCT OPTIONS
A. Products Specified by Reference Standards or by Description Only: Use any product meeting
those standards or description.
B. Products Specified by Naming One or More Manufacturers: Use a product of one of the
manufacturers named and meeting specifications, no options or substitutions allowed.
C. Products Specified by Naming One or More Manufacturers with a Provision for Substitutions:
Submit a request for substitution for any manufacturer not named.
SECTION - 024100 DEMOLITION
PART 1 GENERAL
1.1 SECTION INCLUDES
A. Selective demolition of building elements for alteration purposes.
1.2 REFERENCE STANDARDS
A. NFPA 241 - Standard for Safeguarding Construction, Alteration, and Demolition Operations;
2013.
1.3 SUBMITTALS
A. See Section 013000 - Administrative Requirements, for submittal procedures.
B. Demolition Plan: Submit demolition plan as specified by OSHA and local authorities.
1. Indicate extent of demolition, removal sequence, bracing and shoring, and location and
construction of barricades and fences.
2. Identify demolition firm and submit qualifications.
C. Project Record Documents: Accurately record actual locations of capped and active utilities
and subsurface construction.
PART 3 EXECUTION
3.1 SCOPE
A. Remove portions of existing buildings as indicated to perform overall scope of Work.
B. Remove other items indicated, for salvage, relocation, recycling, and .
3.2 GENERAL PROCEDURES AND PROJECT CONDITIONS
A. Comply with other requirements specified in Section 017000.
B. Comply with applicable codes and regulations for demolition operations and safety of adjacent
structures and the public.
1. Obtain required permits.
2. Take precautions to prevent catastrophic or uncontrolled collapse of structures to be
removed; do not allow worker or public access within range of potential collapse of
unstable structures.
3. Provide, erect, and maintain temporary barriers and security devices.
4. Conduct operations to minimize effects on and interference with adjacent structures and
occupants.
5. Do not close or obstruct roadways or sidewalks without permit.
6. Conduct operations to minimize obstruction of public and private entrances and exits; do
not obstruct required exits at any time; protect persons using entrances and exits from
removal operations.
7. Obtain written permission from owners of adjacent properties when demolition equipment
will traverse, infringe upon or limit access to their property.
C. Do not begin removal until receipt of notification to proceed from Owner.
D. Protect existing structures and other elements that are not to be removed.
1. Provide bracing and shoring.
2. Prevent movement or settlement of adjacent structures.
3. Stop work immediately if adjacent structures appear to be in danger.
E. Minimize production of dust due to demolition operations; do not use water if that will result in
ice, flooding, sedimentation of public waterways or storm sewers, or other pollution.
F. If hazardous materials are discovered during removal operations, stop work and notify
Architect and Owner; hazardous materials include regulated asbestos containing materials,
lead, PCB's, and mercury.
G. Perform demolition in a manner that maximizes salvage and recycling of materials.
1. Dismantle existing construction and separate materials.
2. Set aside reusable, recyclable, and salvageable materials; store and deliver to collection
point or point of reuse.
H. Partial Removal of Paving and Curbs: Neatly saw cut at right angle to surface.
3.3 EXISTING UTILITIES
A. Coordinate work with utility companies; notify before starting work and comply with their
requirements; obtain required permits.
B. Protect existing utilities to remain from damage.
C. Do not disrupt public utilities without permit from authority having jurisdiction.
D. Do not close, shut off, or disrupt existing life safety systems that are in use without at least 7
days prior written notification to Owner.
E. Do not close, shut off, or disrupt existing utility branches or take-offs that are in use without at
least 3 days prior written notification to Owner.
F. Locate and mark utilities to remain; mark using highly visible tags or flags, with identification of
utility type; protect from damage due to subsequent construction, using substantial barricades
if necessary.
G. Remove exposed piping, valves, meters, equipment, supports, and foundations of
disconnected and abandoned utilities.
3.4 SELECTIVE DEMOLITION FOR ALTERATIONS
A. Drawings showing existing construction and utilities are based on casual field observation and
existing record documents only.
1. Verify that construction and utility arrangements are as indicated.
2. Report discrepancies to Architect before disturbing existing installation.
3. Beginning of demolition work constitutes acceptance of existing conditions that would be
apparent upon examination prior to starting demolition.
B. Maintain weatherproof exterior building enclosure except for interruptions required for
replacement or modifications; take care to prevent water and humidity damage.
C. Remove existing work as indicated and as required to accomplish new work.
1. Remove rotted wood, corroded metals, and deteriorated masonry and concrete; replace
with new construction specified.
2. Remove items indicated on drawings.
D. Services (Including but not limited to HVAC, Plumbing, Fire Protection, Electrical, and
Telecommunications): Remove existing systems and equipment as indicated.
1. Maintain existing active systems that are to remain in operation; maintain access to
equipment and operational components.
2. Where existing active systems serve occupied facilities but are to be replaced with new
services, maintain existing systems in service until new systems are complete and ready
for service.
3. Verify that abandoned services serve only abandoned facilities before removal.
4. Remove abandoned pipe, ducts, conduits, and equipment, including those above
accessible ceilings; remove back to source of supply where possible, otherwise cap stub
and tag with identification.
E. Protect existing work to remain.
1. Prevent movement of structure; provide shoring and bracing if necessary.
2. Perform cutting to accomplish removals neatly and as specified for cutting new work.
3. Repair adjacent construction and finishes damaged during removal work.
4. Patch as specified for patching new work.
3.5 DEBRIS AND WASTE REMOVAL
A. Remove debris, junk, and trash from site.
B. Leave site in clean condition, ready for subsequent work.
C. Clean up spillage and wind-blown debris from public and private lands.
SHEET NUMBER
4040 N CENTRAL EXPY,
SUITE 720
DALLAS, TEXAS 75204
t 314.302.6864
www.modusarchitecture.com
FOR INFORMATION
PURPOSES ONLY. NOT TO
BE USED IN ANY CAPACITY
FOR BIDDING, PERMITTING,
OR CONSTRUCTION
REVISIONS:
SHEET NAME
ISSUE DATE:
16
2
5
L
A
N
C
A
S
T
E
R
D
R
I
V
E
GR
A
P
E
V
I
N
E
,
T
E
X
A
S
7
6
0
5
1
G130
SPECIFICATIONS
PE
R
M
I
T
S
E
T
CO
O
K
C
H
I
L
D
R
E
N
'
S
12/19/2024
C. Designation U-MC - Non-sag Polyurethane Sealant: ASTM C 920, Grade NS, Class 25, Uses
NT, I, M, A, G, O; single component, chemical curing, non-staining, non bleeding, capable of
continuous water immersion, non-sagging Designation.
1. Color: Standard colors matching finished surfaces.
2. Product: NP-2 manufactured by Sonneborn.
3. Movement Capability: Plus and minus 25 percent.
4. Service Temperature Range: -40 to 180 degrees F.
5. Shore A Hardness Range: 20 to 35.
D. Designation U-SL - Self-Leveling Polyurethane Sealant: ASTM C 920, Grade P, Class 25,
Uses T, I, M, A, O; single component, chemical curing, non staining, non bleeding, capable of
continuous water immersion, self-leveling Designation.
1. Color: Color as selected.
2. Product: SL-2 manufactured by Sonneborn.
3. Movement Capability: Plus and minus 25 percent.
4. Service Temperature Range: -40 to 180 degrees F.
5. Shore A Hardness Range: 20 to 35.
E. Designation S-GP - Silicone Sealant: ASTM C 920, Grade NS, Class 25, Uses NT, A, G, M, O;
single component, solvent curing, non-sagging, non-staining, fungus resistant, non-bleeding.
1. Color: Standard colors matching finished surfaces.
2. Product: 795 manufactured by Dow Corning.
3. Movement Capability: Plus and minus 25 percent.
4. Service Temperature Range: -65 to 180 degrees F.
5. Shore A Hardness Range: 15 to 35.
F. Designation S-S - Silicone Sealant: ASTM C 920, Grane NS, Class 25, Uses NG, A, G, M, O;
single component, non-sagging, non-staining, sanitary.
1. Color: Standard colors matching finished surfaces.
2. Product: 786 manufactured by Dow Corning.
3. Service Temperature Range: -65 to 180 degrees F.
4. Shore A Hardness Range: 15 to 35.
5. Pre-Formed Elastomeric Foam Seal (PF): Protectowrap Triple Guard energy Sill Sealer.
2.3 ACCESSORIES
A. Primer: Non-staining Designation, recommended by sealant manufacturer to suit application.
B. Joint Backing: Round foam rod compatible with sealant; ASTM D 1667, closed cell PVC;
oversized 30 to 50 percent larger than joint width.
C. Bond Breaker: Pressure sensitive tape recommended by sealant manufacturer to suit
application.
PART 3 - EXECUTION
3.1 EXAMINATION
A. Verify that substrate surfaces are ready to receive work.
B. Verify that joint backing and release tapes are compatible with sealant.
3.2 PREPARATION
A. Remove loose materials and foreign matter that could impair adhesion of sealant.
B. Masking Tape: Use masking tape where required to prevent contact of sealant with adjoining
surfaces that otherwise would be permanently stained or damaged by such contact or by
cleaning methods required to remove sealant smears. Remove tape immediately after tooling
without disturbing joint seal.
C. Clean and prime joints in accordance with manufacturer's instructions. Confine primers to
areas of joint-sealant bond; do not allow spillage or migration onto adjoining surfaces.
D. Perform preparation in accordance with manufacturer's instructions and ASTM C1193.
E. Protect elements surrounding the work of this section from damage or disfigurement.
3.3 INSTALLATION
A. Perform work in accordance with sealant manufacturer's requirements for preparation of
surfaces and material installation instructions.
B. Perform installation in accordance with ASTM C1193.
C. Perform acoustical sealant application work in accordance with ASTM C919 and USG manual.
D. Measure joint dimensions and size joint backers to achieve width-to-depth ratio, neck
dimension, and surface bond area as recommended by manufacturer, except where specific
dimensions are indicated.
E. Install bond breaker where joint backing is not used.
F. Install sealant free of air pockets, foreign embedded matter, ridges, and sags.
G. Apply sealant within recommended application temperature ranges. Consult manufacturer
when sealant cannot be applied within these temperature ranges.
H. Tool joints concave.
I. Pre-compressed Foam Sealant: Do not stretch; avoid joints except at corners, ends, and
intersections; install with face 1/8 to 1/4 inch below adjoining surface.
3.4 CLEANING
A. Clean adjacent soiled surfaces.
3.5 PROTECTION
A. Protect sealants until cured.
3.6 SCHEDULE
A. Exterior Joints for Which No Other Sealant Designation is Indicated: Designation S-GP.
B. Control and Expansion Joints in Paving: Designation U-SL.
C. Interior Wall Expansion Joints: Designation U-MC.
D. Exterior Wall Expansion Joints: Designation S-GP.
E. Control, Expansion, and Soft Joints in Masonry, and Between Masonry and Adjacent Work:
Designation S-GP.
F. Lap Joints in Exterior Sheet Metal Work: Designation S-GP.
G. Joints Between Exterior Metal Frames and Adjacent Work: Designation S-GP.
H. Under Exterior Door Thresholds: Designation S-GP.
I. Interior Joints for Which No Other Sealant is Indicated: Designation AL.
J. Control and Expansion Joints in Interior Concrete Slabs and Floors: Designation U-SL.
K. Joints Between Plumbing Fixtures and Walls and Floors, and Between Countertops and Walls:
Designation S-S.
L. In STC-Rated Walls, Between Metal Stud Track/Runner and Adjacent Construction:
Designation AL-A.
M. Between Slab on Grade and Exterior Wall Sill Plates: Designation PF.
N. Between Slab and Sill Receivers at Aluminum Storefront: Bituminous Mastic.
SECTION 079005 - JOINT SEALERS
PART 1 - GENERAL
1.1 SECTION INCLUDES
A. Sealants and joint backing at the juncture of all dis-similar materials.
B. Pre-compressed foam sealers.
1.2 ADMINISTRATIVE REQUIREMENTS
A. Coordinate the work with other sections referencing this section.
1.3 SUBMITTALS
A. See Section 013000 - Administrative Requirements, for submittal procedures.
B. Product Data: Provide data indicating sealant chemical characteristics.
C. Samples: Submit one sample for each Designation and color of joint sealant required. Samples
shall be installed in 1/2 inch wide joints formed between two 6 inch long strips of material
matching the appearance of exposed surfaces adjacent to joint sealants.
D. Compatibility and Adhesion Test Reports: Submit reports from joint sealant manufacturer
indicating:
1. Materials forming joint substrates and joint sealant backings have been tested for
compatibility and adhesion with joint sealants.
2. Interpretation of test results and written recommendations for primers and substrate
preparation needed for adhesion.
E. Manufacturer's Installation Instructions: Indicate special procedures.
1.4 QUALITY ASSURANCE
A. Manufacturer Qualifications: Company specializing in manufacturing the Products specified in
this section with minimum three years documented experience.
B. Applicator Qualifications: Company specializing in performing the work of this section with
minimum three years experience.
C. Do not apply sealants if ambient or substrate temperatures are below 40 degrees and rising.
1.5 FIELD CONDITIONS
A. Maintain temperature and humidity recommended by the sealant manufacturer during and after
installation.
1.6 WARRANTY
A. See Section 017800 - Closeout Submittals, for additional warranty requirements.
B. Correct defective workmanship within a five-year period after Date of Substantial Completion.
C. Correct defective materials for 5 years for urethane sealants and 20 years for silicone
sealants.
D. Warranty: Include coverage for installed sealants and accessories which fail to achieve airtight
seal, exhibit loss of adhesion or cohesion, or do not cure.
PART 2 - PRODUCTS
2.1 MANUFACTURERS
A. Silicone Sealants:
1. Bostik Inc HYPERLINK "http://www.bostik-us.com/": www.bostik-us.com.
2. Momentive Performance Materials, Inc (formerly GE Silicones HYPERLINK
"http://www.momentive.com/"): www.momentive.com.
3. Pecora Corporati HYPERLINK "http://www.pecora.com/"on: www.pecora.com.
4. BASF Construction Chemicals-Building Systems HYPERLINK
"http://www.buildingsystems.basf.com/": www.buildingsystems.basf.com.
5. Tremco Global Sealants HYPERLINK "http://www.tremcosealants.com/":
www.tremcosealants.com.
6. Substitutions: See Section 01 6000 - Product Requirements.
B. Polyurethane Sealants:
1. Bostik Inc HYPERLINK "http://www.bostik-us.com/": www.bostik-us.com.
2. Pecora Corporati HYPERLINK "http://www.pecora.com/"on: www.pecora.com.
3. BASF Construction Chemicals-Building Systems HYPERLINK
"http://www.buildingsystems.basf.com/": www.buildingsystems.basf.com.
4. Substitutions: See Section 01 6000 - Product Requirements.
C. Acrylic Sealants (ASTM C920):
1. Tremco Global Sealants HYPERLINK "http://www.tremcosealants.com/":
www.tremcosealants.com.
2. Substitutions: See Section 01 6000 - Product Requirements.
D. Acrylic Emulsion Latex Sealants:
1. Bostik Inc HYPERLINK "http://www.bostik-us.com/": www.bostik-us.com.
2. Pecora Corporati HYPERLINK "http://www.pecora.com/"on: www.pecora.com.
3. BASF Construction Chemicals-Building Systems HYPERLINK
"http://www.buildingsystems.basf.com/": www.buildingsystems.basf.com.
4. Tremco Global Sealants HYPERLINK "http://www.tremcosealants.com/":
www.tremcosealants.com.
5. Substitutions: See Section 01 6000 - Product Requirements.
E. Preformed Compressible Foam Sealers:
1. EMSEAL Joint Systems, Ltd: HYPERLINK "http://www.emseal.com/"www.emseal.com.
2. Hohmann & Barnard: wwwh-b.com.
3. Dayton Superior Corporati HYPERLINK "http://www.daytonsuperior.com/"on:
www.daytonsuperior.com.
4. Tremco Global Sealants HYPERLINK "http://www.tremcosealants.com/":
www.tremcosealants.com.
5. Substitutions: See Section 016000 - Product Requirements.
2.2 SEALANTS
A. Designation AL-A - Acoustical Sealant: Butyl or acrylic sealant; ASTM C 920, Grade NS, Class
12-1/2, Uses M and A; single component, solvent release curing, non-skinning.
1. Product: BA-98 manufactured by Pecora.
B. Designation AL - Acrylic Sealant: ASTM C 920, Grade NS, Class 12-1/2, Uses NT, M, A, O;
single component, solvent curing, non-staining, non-bleeding, non-sagging.
1. Color: Standard colors matching finished surfaces.
2. Product: Sonolac manufactured by Sonneborn.
3. Movement Capability: Plus and minus 12-1/2 percent.
4. Service Temperature Range: -13 to 180 degrees F.
5. Shore A Hardness Range: 25 to 50.
6. Applications: Use for:
D. Foam Firestoppping: Single component silicone foam compound.
1. Manufacturers:
a. 3M Fire Protection Products HYPERLINK "http://www.3m.com/firestop":
www.3m.com/firestop.
b. Hilti, Inc HYPERLINK "http://www.us.hilti.com/": www.us.hilti.com.
c. Specified Technologies, Inc HYPERLINK "http://www.stifirestop.com/":
www.stifirestop.com.
d. Substitutions: See Section 016000 - Product Requirements.
E. Fibered Compound Firestopping: Formulated compound mixed with incombustible non-asbestos
fibers.
1. Manufacturers:
a. A/DFire Protection Systems Inc HYPERLINK "http://www.adfire.com/":
www.adfire.com.
b. USG HYPERLINK "http://www.usg.com/": www.usg.com.
c. Substitutions: See Section 016000 - Product Requirements.
F. Fiber Firestopping: Mineral fiber insulation used in conjunction with elastomeric surface sealer
forming airtight bond to opening.
1. Manufacturers:
a. A/DFire Protection Systems Inc HYPERLINK "http://www.adfire.com/":
www.adfire.com.
b. Pecora Corporati HYPERLINK "http://www.pecora.com/"on: www.pecora.com.
c. Thermafiber, Inc HYPERLINK "http://www.thermafiber.com/": www.thermafiber.com.
d. Substitutions: See Section 016000 - Product Requirements.
G. Firestop Devices - Wrap Type: Mechanical device with incombustible filler and sheet stainless
steel jacket, intended to be installed after penetrating item has been installed.
1. Manufacturers:
a. RectorSeal HYPERLINK "http://www.rectorseal.com/": www.rectorseal.com.
b. 3M Fire Protection Products HYPERLINK "http://www.3m.com/firestop":
www.3m.com/firestop.
c. Hilti, Inc HYPERLINK "http://www.us.hilti.com/": www.us.hilti.com.
d. Specified Technologies, Inc HYPERLINK "http://www.stifirestop.com/":
www.stifirestop.com.
e. Substitutions: See Section 016000 - Product Requirements.
H. Intumescent Putty: Compound that expands on exposure to surface heat gain.
1. Manufacturers:
a. RectorSeal HYPERLINK "http://www.rectorseal.com/": www.rectorseal.com.
b. 3M Fire Protection Products HYPERLINK "http://www.3m.com/firestop":
www.3m.com/firestop.
c. Hilti, Inc HYPERLINK "http://www.us.hilti.com/": www.us.hilti.com.
d. Specified Technologies, Inc HYPERLINK "http://www.stifirestop.com/":
www.stifirestop.com.
e. Substitutions: See Section 016000 - Product Requirements.
I. Reusable Firestopping: Removable intumescent compressible shapes, pillows, or blocks
specifically tested in removable configuration.
1. Manufacturers:
A. RectorSeal HYPERLINK "http://www.rectorseal.com/": www.rectorseal.com.
B. Hilti, Inc HYPERLINK "http://www.us.hilti.com/": www.us.hilti.com.
C. Nelson FireStop Products HYPERLINK "http://www.nelsonfirestop.com/":
www.nelsonfirestop.com.
D. Specified Technologies, Inc HYPERLINK "http://www.stifirestop.com/":
www.stifirestop.com.
E. Substitutions: See Section 016000 - Product Requirements.
J. Primers, Sleeves, Forms, Insulation, Packing, Stuffing, and Accessories: Type required for
tested assembly design.
1. Use only components specified by through-penetration firestop system manufacturer
and approved by the qualified testing and inspecting agency for firestop systems
indicated.
PART 3 EXECUTION
3.1 EXAMINATION
A. Verify openings are ready to receive the work of this section.
3.2 PREPARATION
A. Clean substrate surfaces of dirt, dust, grease, oil, loose material, or other materials that could
adversely affect bond of firestopping material.
B. Remove incompatible materials that could adversely affect bond.
C. Install backing materials to prevent liquid material from leakage.
3.3 INSTALLATION
A. Install materials in manner described in fire test report and in accordance with manufacturer's
instructions, completely closing openings.
B. Do not cover installed firestopping until inspected by authorities having jurisdiction.
C. Install labeling required by code.
3.4 FIELD QUALITY CONTROL
A. Independent Testing Agency: Inspection agency employed and paid by Owner, will examine
penetration firestopping in accordance with ASTM E2174, and ASTM E2393.
B. Repair or replace penetration firestopping and joints at locations where inspection results
indicate firestopping or joints do not meet specified requirements.
3.5 CLEANING
A. Clean adjacent surfaces of firestopping materials.
3.6 PROTECTION
A. Protect adjacent surfaces from damage by material installation.
SECTION 078400 - FIRESTOPPING
PART 1 GENERAL
1.1 SECTION INCLUDES
A. Firestopping systems.
B. Firestopping of all joints and penetrations in fire resistance rated and smoke resistant
assemblies, and other openings indicated.
1.2 REFERENCE STANDARDS
A. ASTM E2174 - Standard Practice for On-Site Inspection of Installed Firestops; 2014b.
B. ASTM E2393 - Standard Practice for On-Site Inspection of Installed Fire Resistive Joint
Systems and Perimeter Fire Barriers; 2010a (Reapproved 2015).
C. UL (FRD) - Fire Resistance Directory; Current Edition.
1.3 SUBMITTALS
A. See Section 013000 - Administrative Requirements, for submittal procedures.
B. Schedule of Firestopping: List each type of penetration, fire rating of the penetrated assembly,
and firestopping test or design number.
C. Product Data: Provide data on product characteristics, performance ratings, and limitations.
D. Manufacturer's Installation Instructions: Indicate preparation and installation instructions.
E. Manufacturer's Certificate: Certify that products meet or exceed specified requirements.
F. Certificate from authority having jurisdiction indicating approval of materials used.
G. Installer Qualification: Submit qualification statements for installing mechanics.
1.4 QUALITY ASSURANCE
A. Fire Testing: Provide firestopping assemblies of designs that provide the scheduled fire ratings
when tested in accordance with methods indicated.
1. Listing in UL (FRD) will be considered as constituting an acceptable test report.
2. Valid evaluation report published by ICC Evaluation Service, Inc. (ICC-ES) at www.icc-
es.org will be considered as constituting an acceptable test report.
3. Submission of actual test reports is required for assemblies for which none of the above
substantiation exists.
B. Manufacturer Qualifications: Company specializing in manufacturing the products specified in
this section with minimum three years documented experience.
C. Installer Qualifications: Company specializing in performing the work of this section and:
1. Trained by manufacturer.
2. Verification of minimum three years documented experience installing work of this type.
3. Verification of at least five satisfactorily completed projects of comparable size and type.
4. Licensed by local authorities having jurisdiction (AHJ).
1.5 FIELD CONDITIONS
A. Comply with firestopping manufacturer's recommendations for temperature and conditions
during and after installation; maintain minimum temperature before, during, and for three days
after installation of materials.
B. Provide ventilation in areas where solvent-cured materials are being installed.
PART 2 PRODUCTS
2.1 FIRESTOPPING - GENERAL REQUIREMENTS
A. Primers, Sleeves, Forms, Insulation, Packing, Stuffing, and Accessories: Type required for
tested assembly design.
2.2 FIRESTOPPING SYSTEMS
A. Firestopping: Any material meeting requirements of approved assembly.
2.3 MATERIALS
A. Primers, Sleeves, Forms, Insulation, Packing, Stuffing, and Accessories: Provide type of
materials as required for tested firestopping assembly.
B. Fire Ratings: Refer to drawings for required systems and ratings.
C. Elastomeric Silicone Firestopping: Single component silicone elastomeric compound and
compatible silicone sealant.
1. Manufacturers:
a. A/DFire Protection Systems Inc: www.adfire.com.
b. 3M Fire Protection Products: www.3m.com/firestop.
c. Hilti, Inc: www.us.hilti.com.
d. Specified Technologies, Inc: www.stifirestop.com.
e. Substitutions: See Section 016000 - Product Requirements.
SECTION 062000 - FINISH CARPENTRY
PART 1 GENERAL
1.1 SECTION INCLUDES
A. Finish carpentry items.
B. Wood casings and moldings.
1.2 REFERENCE STANDARDS
A. ASTM E84 - Standard Test Method for Surface Burning Characteristics of Building Materials;
2017.
B. AWI (QCP) - Quality Certification Program; current edition at www.awiqcp.org.
C. AWI/AWMAC/WI (AWS) - Architectural Woodwork Standards; 2014, with Errata (2016).
1.3 ADMINISTRATIVE REQUIREMENTS
A. Coordinate the work with plumbing rough-in, electrical rough-in, and installation of associated
and adjacent components.
B. Sequence installation to ensure utility connections are achieved in an orderly and expeditious
manner.
1.4 SUBMITTALS
A. See Section 013000 - Administrative Requirements for submittal procedures.
B. Product Data:
1. Provide data on fire retardant treatment materials and application instructions.
2. Provide instructions for attachment hardware.
C. Shop Drawings: Indicate materials, component profiles, fastening methods, jointing details, and
accessories.
1. Scale of Drawings: 1-1/2 inch to 1 foot, minimum.
2. Provide the information required by AWI/AWMAC/WI (AWS).
3. Include certification program label.
D. Samples: Submit two samples of wood trim 6 inch long.
E. Certificate: Submit labels and certificates required by quality assurance and quality control
programs.
1.5 QUALITY ASSURANCE
A. Fabricator Qualifications: Company specializing in fabricating the products specified in this
section with minimum five years of documented experience.
1. Company with at least one project within the past 5 years with value of woodwork within
20 percent of cost of woodwork for this project.
2. Accredited participant in the specified certification program prior to the commencement of
fabrication and throughout the duration of the project.
B. Quality Certification:
1. Comply with AWI (QCP) woodwork association quality certification service/program in
accordance with requirements for work specified in this section: www.awiqcp.org/#sle.
2. Provide labels or certificates indicating that the work complies with AWI/AWMAC/WI
(AWS) requirements for grade or grades specified.
3. Provide designated labels on shop drawings as required by certification program.
4. Provide designated labels on installed products as required by certification program.
5. Submit certifications upon completion of installation that verifies this work is in compliance
with specified requirements.
1.6 DELIVERY, STORAGE, AND HANDLING
A. Protect work from moisture damage.
PART 2 PRODUCTS
2.1 FINISH CARPENTRY ITEMS
A. Quality Standard: Custom Grade, in accordance with AWI/AWMAC/WI (AWS), unless noted
otherwise.
B. Surface Burning Characteristics: Provide materials having fire and smoke properties as
required by applicable code.
C. Interior Woodwork Items:
1. Moldings, Bases, Casings, and Miscellaneous Trim: Maple, prepare for transparent finish.
2. Stair Treads: Maple, prepare for transparent finish.
3. "Fin Element": Suspended maple boards as detailed, transparent finish. Refer to Section
055000 for turnbuckle hardware.
2.2 LUMBER MATERIALS
A. Hardwood Lumber: Maple species, plain sawn, maximum moisture content of 6 percent; with
vertical grain, of quality suitable for transparent finish.
2.3 FASTENINGS
A. Adhesive for Purposes Other Than Laminate Installation: Suitable for the purpose; not
containing formaldehyde or other volatile organic compounds.
B. Fasteners: Of size and type to suit application, finishes as approved by Architect.
C. Concealed Joint Fasteners: Threaded steel.
2.4 ACCESSORIES
A. Lumber for Shimming and Blocking: Softwood lumber of any species as specified in Section
061000.
B. Primer: Alkyd primer sealer.
C. Wood Filler: Solvent base, tinted to match surface finish color.
2.5 WOOD TREATMENT
A. Fire Retardant Treatment (FR-S Type): Chemically treated and pressure impregnated; capable
of providing flame spread index of 25, maximum, and smoke developed index of 450,
maximum, when tested in accordance with ASTM E84.
B. Shop pressure treat wood materials requiring fire rating to concealed wood blocking.
C. Provide identification on fire retardant treated material.
D. Deliver fire retardant treated materials cut to required sizes. Minimize field cutting.
E. Redry wood after pressure treatment to maximum 9 percent moisture content.
2.6 FABRICATION
A. Shop assemble work for delivery to site, permitting passage through building openings.
B. When necessary to cut and fit on site, provide materials with ample allowance for cutting.
Provide trim for scribing and site cutting.
2.7 SHOP FINISHING
A. Sand work smooth and set exposed nails and screws.
B. Apply wood filler in exposed nail and screw indentations.
C. On items to receive transparent finishes, use wood filler that matches surrounding surfaces
and is of type recommended for the applicable finish.
D. Finish work in accordance with AWI/AWMAC/WI (AWS), Section 5 - Finishing for grade
specified and as follows:
1. Transparent:
a. System - 11, Polyurethane, Catalyzed.
b. Sheen: As scheduled.
PART 3 EXECUTION
3.1 EXAMINATION
A. Verify adequacy of backing and support framing.
B. Verify mechanical, electrical, and building items affecting work of this section are placed and
ready to receive this work.
C. See Section 061000 for installation of recessed wood blocking.
3.2 INSTALLATION
A. Install work in accordance with AWI/AWMAC/WI (AWS) requirements for grade indicated.
B. Set and secure materials and components in place, plumb and level.
C. Carefully scribe work abutting other components, with maximum gaps of 1/32 inch. Do not use
additional overlay trim to conceal larger gaps.
3.3 PREPARATION FOR SITE FINISHING
A. Set exposed fasteners. Apply wood filler in exposed fastener indentations. Sand work smooth.
B. Before installation, prime paint surfaces of items or assemblies to be in contact with
cementitious materials.
3.4 TOLERANCES
A. Maximum Variation from True Position: 1/16 inch.
B. Maximum Offset from True Alignment with Abutting Materials: 1/32 inch.
C. Prevent sawdust and wood shavings from entering the storm drainage system.
SECTION 061000 - ROUGH CARPENTRY
PART 1 GENERAL
1.1 SECTION INCLUDES
B. Preservative treated wood materials.
C. Fire retardant treated wood materials.
D. Miscellaneous wood nailers, furring, and grounds.
1.2 REFERENCE STANDARDS
A. ASTM A153/A153M - Standard Specification for Zinc Coating (Hot-Dip) on Iron and Steel
Hardware; 2016a.
B. ASTM D2898 - Standard Test Methods for Accelerated Weathering of Fire-Retardant-Treated
Wood for Fire Testing; 2010 (Reapproved 2017).
C. ASTM E84 - Standard Test Method for Surface Burning Characteristics of Building Materials;
2017.
D. AWPA U1 - Use Category System: User Specification for Treated Wood; 2017.
E. PS 1 - Structural Plywood; 2009.
F. PS 20 - American Softwood Lumber Standard; 2015.
G. SPIB (GR) - Grading Rules; 2014.
1.3 SUBMITTALS
A. See Section 013000 - Administrative Requirements, for submittal procedures.
B. Product Data: Provide technical data on insulated sheathing, wood preservative materials, and
application instructions.
C. Manufacturer's Certificate: Certify that wood products supplied for rough carpentry meet or
exceed specified requirements.
1.4 DELIVERY, STORAGE, AND HANDLING
A. General: Cover wood products to protect against moisture. Support stacked products to
prevent deformation and to allow air circulation.
B. Fire Retardant Treated Wood: Prevent exposure to precipitation during shipping, storage, or
installation.
PART 2 PRODUCTS
2.1 GENERAL REQUIREMENTS
A. Dimension Lumber: Comply with PS 20 and requirements of specified grading agencies.
1. Species: Southern Pine, unless otherwise indicated.
2. If no species is specified, provide any species graded by the agency specified; if no
grading agency is specified, provide lumber graded by any grading agency meeting the
specified requirements.
3. Grading Agency: Any grading agency whose rules are approved by the Board of Review,
American Lumber Standard Committee (www.alsc.org) and who provides grading service
for the species and grade specified; provide lumber stamped with grade mark unless
otherwise indicated.
4. Lumber of other species or grades is acceptable provided structural and appearance
characteristics are equivalent to or better than products specified.
2.2 DIMENSION LUMBER FOR CONCEALED APPLICATIONS
A. Grading Agency: Southern Pine Inspection Bureau, Inc; SPIB (GR).
B. Sizes: Nominal sizes as indicated on drawings, S4S.
C. Moisture Content: S-dry or MC19.
D. Miscellaneous Framing, Blocking, Nailers, Grounds, and Furring:
1. Lumber: S4S, No. 2 or Standard Grade.
2. Boards: Standard or No. 3.
2.3 CONSTRUCTION PANELS
A. Communications and Electrical Room Mounting Boards: PS 1 A-D plywood, or medium density
fiberboard; 3/4 inch thick; flame spread index of 25 or less, smoke developed index of 450 or
less, when tested in accordance with ASTM E84.
B. Other Applications:
1. Plywood Concealed From View But Located Within Exterior Enclosure: PS 1, C-C Plugged
or better, Exterior grade.
2. Plywood Exposed to View But Not Exposed to Weather: PS 1, A-D, or better.
3. Other Locations: PS 1, C-D Plugged or better.
2.4 ACCESSORIES
A. Fasteners and Anchors:
1. Metal and Finish: Hot-dipped galvanized steel complying with ASTM A153/A153M for high
humidity and preservative-treated wood locations, unfinished steel elsewhere.
2. Drywall Screws: Bugle head, hardened steel, power driven type, length three times
thickness of sheathing.
3. Anchors: Toggle bolt type for anchorage to hollow masonry.
B. Construction Adhesives:
1. Manufacturers:
a. Franklin International, Inc; Titebond Fast Set Polyurethane Construction Adhesive:
HYPERLINK "http://www.titebond.com/#sle" www.titebond.com/#sle.
b. Substitutions: See Section 016000 - Product Requirements.
2.5 FACTORY WOOD TREATMENT
A. Treated Lumber and Plywood: Comply with requirements of AWPA U1 - Use Category System
for wood treatments determined by use categories, expected service conditions, and specific
applications.
1. Fire-Retardant Treated Wood: Mark each piece of wood with producer's stamp indicating
compliance with specified requirements.
2. Preservative-Treated Wood: Provide lumber and plywood marked or stamped by an
ALSC-accredited testing agency, certifying level and type of treatment in accordance with
AWPA standards.
B. Fire Retardant Treatment:
1. Manufacturers:
a. Lonza Gro HYPERLINK "http://www.wolmanizedwood.com/#sle"up:
www.wolmanizedwood.com/#sle.
b. Hoover Treated Wood Products, Inc HYPERLINK "http://www.frtw.com/#sle":
www.frtw.com/#sle.
c. Koppers, Inc HYPERLINK "http://www.koppersperformancechemicals.com/#sle":
www.koppersperformancechemicals.com/#sle.
d. Viance, LLC; D-Blaz HYPERLINK "http://www.treatedwood.com/#sle"e:
www.treatedwood.com/#sle.
e. Substitutions: See Section 016000 - Product Requirements.
2. Exterior Type: AWPA U1, Category UCFB, Commodity Specification H, chemically treated
and pressure impregnated; capable of providing a maximum flame spread index of 25
when tested in accordance with ASTM E84, with no evidence of significant combustion
when test is extended for an additional 20 minutes both before and after accelerated
weathering test performed in accordance with ASTM D2898.
a. Kiln dry wood after treatment to a maximum moisture content of 19 percent for lumber
and 15 percent for plywood.
b. Do not use treated wood in direct contact with the ground.
3. Interior Type A: AWPA U1, Use Category UCFA, Commodity Specification H, low
temperature (low hygroscopic) type, chemically treated and pressure impregnated;
capable of providing a maximum flame spread index of 25 when tested in accordance with
ASTM E84, with no evidence of significant combustion when test is extended for an
additional 20 minutes.
a. Kiln dry wood after treatment to a maximum moisture content of 19 percent for lumber
and 15 percent for plywood.
b. Treat rough carpentry items as indicated .
c. Do not use treated wood in applications exposed to weather or where the wood may
become wet.
A. Preservative Treatment:
1. Manufacturers:
a. Lonza Gro HYPERLINK "http://www.wolmanizedwood.com/#sle"up:
www.wolmanizedwood.com/#sle.
b. Koppers Performance Chemicals HYPERLINK
"http://www.koppersperformancechemicals.com/#sle", Inc:
www.koppersperformancechemicals.com/#sle.
c. Viance, LLC; Preserve ACQ HYPERLINK "http://www.treatedwood.com/#sle":
www.treatedwood.com/#sle.
d. Substitutions: See Section 016000 - Product Requirements.
2. Preservative Pressure Treatment of Lumber Above Grade: AWPA U1, Use Category
UC3B, Commodity Specification A using waterborne preservative.
a. Kiln dry lumber after treatment to maximum moisture content of 19 percent.
b. Treat lumber in contact with roofing, flashing, or waterproofing.
c. Treat lumber in contact with masonry or concrete.
3. Preservative Pressure Treatment of Lumber in Contact with Soil: AWPA U1, Use
Category UC4A, Commodity Specification A using waterborne preservative.
a. Preservative for Field Application to Cut Surfaces: As recommended by manufacturer
of factory treatment chemicals for brush-application in the field.
PART 3 EXECUTION
3.1 PREPARATION
A. Coordinate installation of rough carpentry members specified in other sections.
1. INSTALLATION - GENERAL
A. Select material sizes to minimize waste.
B. Reuse scrap to the greatest extent possible; clearly separate scrap for use on site as
accessory components, including: shims, bracing, and blocking.
C. Where treated wood is used on interior, provide temporary ventilation during and immediately
after installation sufficient to remove indoor air contaminants.
3.2 BLOCKING, NAILERS, AND SUPPORTS
A. Provide framing and blocking members as indicated or as required to support finishes, fixtures,
specialty items, and trim.
B. In framed assemblies that have concealed spaces, provide solid wood fireblocking as required
by applicable local code, to close concealed draft openings between floors and between top
story and roof/attic space; other material acceptable to code authorities may be used in lieu of
solid wood blocking.
C. In metal stud walls, provide continuous blocking around door and window openings for
anchorage of frames, securely attached to stud framing.
D. Provide the following specific non-structural framing and blocking:
1. Cabinets and shelf supports.
2. Wall brackets.
3. Grab bars.
4. Towel and bath accessories.
5. Wall-mounted door stops.
6. Chalkboards and marker boards.
3.3 INSTALLATION OF CONSTRUCTION PANELS
A. Communications and Electrical Room Mounting Boards: Secure with screws to studs with
edges over firm bearing; space fasteners at maximum 24 inches on center on all edges and
into studs in field of board.
1. At fire-rated walls, install board over wall board indicated as part of the fire-rated
assembly.
2. Where boards are indicated as full floor-to-ceiling height, install with long edge of board
parallel to studs.
3. Install adjacent boards without gaps.
4. Size and Location: As indicated on drawings.
3.4 TOLERANCES
A. Framing Members: 1/4 inch from true position, maximum.
B. Variation from Plane (Other than Floors): 1/4 inch in 10 feet maximum, and 1/4 inch in 30 feet
maximum.
3.5 CLEANING
A. Do not leave any wood, shavings, sawdust, etc. on the ground or buried in fill.
B. Prevent sawdust and wood shavings from entering the storm drainage system.
SECTION 064100 - ARCHITECTURAL WOOD CASEWORK
PART 1 GENERAL
1.1 SECTION INCLUDES
A. Specially fabricated cabinet units.
B. Countertops.
1.2 REFERENCE STANDARDS
A. AWI/AWMAC/WI (AWS) - Architectural Woodwork Standards; 2014, with Errata (2016).
B. AWI (QCP) - Quality Certification Program; current edition at www.awiqcp.org.
C. BHMA A156.9 - American National Standard for Cabinet Hardware; 2015.
D. NEMA LD 3 - High-Pressure Decorative Laminates; 2005.
E. UL (DIR) - Online Certifications Directory; Current Edition.
1.3 ADMINISTRATIVE REQUIREMENTS
A. Preinstallation Meeting: Convene a preinstallation meeting not less than one week before
starting work of this section; require attendance by all affected installers.
1.4 SUBMITTALS
A. See Section 013000 - Administrative Requirements, for submittal procedures.
B. Shop Drawings: Indicate materials, component profiles, fastening methods, jointing details, and
accessories.
1. Scale of Drawings: 1-1/2 inch to 1 foot, minimum.
2. Provide the information required by AWI/AWMAC/WI (AWS).
C. Product Data: Provide data for hardware accessories.
D. Samples: Submit actual samples of architectural cabinet construction, minimum 12 inches
square, illustrating proposed cabinet substrate and finish.
1.5 QUALITY ASSURANCE
A. Fabricator Qualifications: Company specializing in fabricating the products specified in this
section with minimum five years of documented experience.
1. Company with at least one project in the past 5 years with value of woodwork within 20
percent of cost of woodwork for this Project.
2. Accredited participant in the specified certification program prior to the commencement of
fabrication and throughout the duration of the project.
B. Quality Certification:
1. Comply with AWI (QCP) woodwork association quality certification service/program in
accordance with requirements for work specified in this section: www.awiqcp.org/#sle.
2. Provide labels or certificates indicating that the installed work complies with
AWI/AWMAC/WI (AWS) requirements for grade or grades specified.
3. Provide designated labels on shop drawings as required by certification program.
4. Provide designated labels on installed products as required by certification program.
5. Submit certifications upon completion of installation that verifies this work is in compliance
with specified requirements.
6. Replace, repair, or rework all work for which certification is refused.
1.7 DELIVERY, STORAGE, AND HANDLING
A. Protect units from moisture damage.
1.8 FIELD CONDITIONS
A. During and after installation of custom cabinets, maintain temperature and humidity conditions
in building spaces at same levels planned for occupancy.
PART 2 PRODUCTS
2.1 CABINETS
A. Quality Standard: Custom Grade, in accordance with AWI/AWMAC/WI (AWS), unless noted
otherwise.
B. Plastic Laminate Faced Cabinets: Custom grade.
2.2 LAMINATE MATERIALS
A. Manufacturers:
1. Formica Corporation: www.formica.com/#sle.
2. Substitutions: See Section 016000 - Product Requirements.
B. High Pressure Decorative Laminate (HPDL): NEMA LD 3, types as recommended for specific
applications.
C. Provide specific types as indicated.
1. Horizontal Surfaces: HGS, 0.048 inch nominal thickness, through color, colors as
indicated, finish as indicated.
2. Vertical Surfaces: VGS, 0.028 inch nominal thickness, through color, colors as indicated,
finish as indicated.
3. Post-Formed Horizontal Surfaces: HGP, 0.039 inch nominal thickness, through color,
colors as indicated, finish as indicated.
4. Cabinet Liner: CLS, 0.020 inch nominal thickness, through color, colors as indicated, finish
as indicated.
5. Laminate Backer: BKL, 0.020 inch nominal thickness, undecorated; for application to
concealed backside of panels faced with high pressure decorative laminate.
2.3 COUNTERTOPS
A. Countertops are specified in Section 123600.
2.4 ACCESSORIES
A. Adhesive: Type recommended by fabricator to suit application.
B. Plastic Edge Banding: Extruded PVC, convex shaped; smooth finish; self locking serrated
tongue; of width to match component thickness.
1. Color: As selected by Architect from manufacturer's standard range.
C. Fasteners: Size and type to suit application.
D. Bolts, Nuts, Washers, Lags, Pins, and Screws: Of size and type to suit application; galvanized
or chrome-plated finish in concealed locations and stainless steel or chrome-plated finish in
exposed locations.
E. Concealed Joint Fasteners: Threaded steel.
F. Grommets: Standard plastic, painted metal, or rubber grommets for cut-outs, in color to match
adjacent surface.
2.5 HARDWARE
A. Hardware: BHMA A156.9, types as recommended by fabricator for quality grade specified.
B. Manufacturers:
1. Accuride International, Inc: www.accuride.com/#sle.
2. Grass America Inc: www.grassusa.com/#sle.
3. Hafele america Co.: www.hafele.com/us/en/
4. Knape & Vogt Manufacturing Company: www.knapeandvogt.com/#sle.
C. Adjustable Shelf Supports: Standard side-mounted system using recessed metal shelf
standards or multiple holes for pin supports and coordinated self rests, polished chrome finish,
for nominal 1 inch spacing adjustments.
D. Drawer and Door Pulls: "U" shaped wire pull, steel with chrome finish, 4 inch centers.
E. Cabinet Locks: Keyed cylinder, two keys per lock, master keyed, steel with chrome finish.
F. Catches: Magnetic.
G. Drawer Slides:
1. Type: Full extension with overtravel.
2. Static Load Capacity: Extra Heavy Duty grade.
3. Mounting: Bottom mounted.
4. Stops: Integral type.
5. Features: Provide self closing/stay closed type.
H. Hinges: European style concealed self-closing type, steel with polished finish.
I. Soft Close Adapter: Concealed, frame-mounted, screw-adjustable damper ; steel with polished
finish.
2.6 SHOP TREATMENT OF WOOD MATERIALS
A. Provide UL (DIR) listed and approved identification on fire retardant treated material.
B. Deliver fire retardant treated materials cut to required sizes. Minimize field cutting.
2.7 FABRICATION
A. Assembly: Shop assemble cabinets for delivery to site in units easily handled and to permit
passage through building openings.
B. Edging: Fit shelves, doors, and exposed edges with specified edging. Do not use more than
one piece for any single length.
C. Fitting: When necessary to cut and fit on site, provide materials with ample allowance for
cutting. Provide matching trim for scribing and site cutting.
D. Plastic Laminate: Apply plastic laminate finish in full uninterrupted sheets consistent with
manufactured sizes. Fit corners and joints hairline; secure with concealed fasteners. Slightly bevel
arises. Locate counter butt joints minimum 2 feet from sink cut-outs.
E. Mechanically fasten back splash to countertops as recommended by laminate manufacturer at
16 inches on center.
F. Provide cutouts for plumbing fixtures. Verify locations of cutouts from on-site dimensions.
Prime paint cut edges.
PART 3 EXECUTION
3.1 EXAMINATION
A. Verify adequacy of backing and support framing.
B. Verify location and sizes of utility rough-in associated with work of this section.
3.2 INSTALLATION
A. Install work in accordance with AWI/AWMAC/WI (AWS) requirements for grade indicated.
B. Set and secure custom cabinets in place, assuring that they are rigid, plumb, and level.
C. Use fixture attachments in concealed locations for wall mounted components.
D. Use concealed joint fasteners to align and secure adjoining cabinet units.
E. Carefully scribe casework abutting other components, with maximum gaps of 1/32 inch. Do not
use additional overlay trim for this purpose.
F. Secure cabinets to floor using appropriate angles and anchorages.
3.3 ADJUSTING
A. Adjust installed work.
B. Adjust moving or operating parts to function smoothly and correctly.
3.4 CLEANING
A. Clean casework, counters, shelves, hardware, fittings, and fixtures.
SECTION 072100 THERMAL INSULATION
PART 1 GENERAL
1.1 SECTION INCLUDES
A. Batt insulation in exterior wall and ceiling construction.
B. Batt insulation for filling perimeter window and door shim spaces and crevices in exterior wall
and roof.
1.2 REFERENCE STANDARDS
A. ASTM C578 - Standard Specification for Rigid, Cellular Polystyrene Thermal Insulation; 2017a.
B. ASTM C665 - Standard Specification for Mineral-Fiber Blanket Thermal Insulation for Light
Frame Construction and Manufactured Housing; 2017.
C. ASTM E84 - Standard Test Method for Surface Burning Characteristics of Building Materials;
2017.
D. ASTM E136 - Standard Test Method for Behavior of Materials in a Vertical Tube Furnace At
750 Degrees C; 2016a.
E. ASTM E2357 - Standard Test Method for Determining Air Leakage of Air Barrier Assemblies;
2017.
F. NFPA 285 - Standard Fire Test Method for Evaluation of Fire Propagation Characteristics of
Exterior Non-Load-Bearing Wall Assemblies Containing Combustible Components; 2012.
1.3 SUBMITTALS
A. See Section 013000 - Administrative Requirements, for submittal procedures.
B. Product Data: Provide data on product characteristics, performance criteria, and product
limitations.
C. Manufacturer's Certificate: Certify that products meet or exceed specified requirements.
D. Manufacturer's Installation Instructions: Include information on special environmental
conditions required for installation and installation techniques.
1.4 FIELD CONDITIONS
A. Do not install insulation adhesives when temperature or weather conditions are detrimental to
successful installation.
PART 2 PRODUCTS
2.1 APPLICATIONS
A. Insulation Behind Spandrel Glass: Extruded polystyrene (XPS) board.
B. Insulation in Metal Framed Walls: Batt insulation with no vapor retarder.
2.2 BATT INSULATION MATERIALS
A. Glass Fiber Batt Insulation: Flexible preformed batt or blanket, complying with ASTM C665;
friction fit.
1. Flame Spread Index: 75 or less, when tested in accordance with ASTM E84.
2. Smoke Developed Index: 450 or less, when tested in accordance with ASTM E84.
3. Combustibility: Non-combustible, when tested in accordance with ASTM E136, except for
facing, if any.
4. Formaldehyde Content: Zero.
5. Thermal Resistance: R-value of 13.
6. Facing: Unfaced.
7. Manufacturers:
a. CertainTeed Corporation: www.certainteed.com/#sle.
b. Johns Manville: www.jm.com/#sle.
c. Owens Corning Corporation: www.ocbuildingspec.com/#sle.
d. Substitutions: See Section 016000 - Product Requirements.
B. Flexible Blanket Insulation: Thin profile insulation that complies with complex shapes, unfaced;
flame spread index of 5 (five) and smoke development index of 10 (ten) or less when tested in
accordance with ASTM E84.
1. Color: Gray.
2. Thickness: 3/8 inch.
3. Manufacturers:
a. Dow Chemical Company:
consumer.dow.com/en-us/industry/ind-building-construction.html/#sle.
b. Substitutions: See Section 016000 - Product Requirements.
2.3 ACCESSORIES
A. Adhesive: Type recommended by insulation manufacturer for application.
PART 3 EXECUTION
3.1 EXAMINATION
A. Verify that substrate, adjacent materials, and insulation materials are dry and that substrates
are ready to receive insulation.
B. Verify substrate surfaces are flat, free of honeycomb, fins, irregularities, or materials or
substances that may impede adhesive bond.
3.2 BOARD INSTALLATION AT EXTERIOR WALLS
A. Install rigid insulation directly to steel studs or exterior grade sheathing at 16 inches on center
with manufacturer recommended mechanical fasteners, and tape joints with manufacturer's
minimum 4 inch wide sealant tape; comply with ASTM E2357.
B. Install boards horizontally on walls.
1. Place boards to maximize adhesive contact.
2. Install in running bond pattern.
3. Butt edges and ends tightly to adjacent boards and to protrusions.
C. Cut and fit insulation tightly to protrusions or interruptions to the insulation plane.
3.3 BATT INSTALLATION
A. Install insulation and vapor retarder in accordance with manufacturer's instructions.
B. Install in exterior wall spaces without gaps or voids. Do not compress insulation.
C. Trim insulation neatly to fit spaces. Insulate miscellaneous gaps and voids.
D. Fit insulation tightly in cavities and tightly to exterior side of mechanical and electrical services
within the plane of the insulation.
3.4 FIELD QUALITY CONTROL
A. See Section 014000 - Quality Requirements, for additional requirements.
3.5 PROTECTION
A. Do not permit installed insulation to be damaged prior to its concealment.
END OF SECTION
SHEET NUMBER
4040 N CENTRAL EXPY,
SUITE 720
DALLAS, TEXAS 75204
t 314.302.6864
www.modusarchitecture.com
FOR INFORMATION
PURPOSES ONLY. NOT TO
BE USED IN ANY CAPACITY
FOR BIDDING, PERMITTING,
OR CONSTRUCTION
REVISIONS:
SHEET NAME
ISSUE DATE:
16
2
5
L
A
N
C
A
S
T
E
R
D
R
I
V
E
GR
A
P
E
V
I
N
E
,
T
E
X
A
S
7
6
0
5
1
G131
SPECIFICATIONS
PE
R
M
I
T
S
E
T
CO
O
K
C
H
I
L
D
R
E
N
'
S
12/19/2024
SECTION 087100 - DOOR HARDWARE
PART 1 - GENERAL
1.1 RELATED DOCUMENTS
A. Drawings and general provisions of the Contract, including General and Supplementary
Conditions and Division 1 Specification Sections, apply to this Section.
1.2 SUMMARY
A. This Section includes commercial door hardware for the following:
1. Swinging doors.
2. Sliding doors.
3. Other doors to the extent indicated.
B. Door hardware includes, but is not necessarily limited to, the following:
1. Mechanical door hardware.
2. Electromechanical door hardware.
3. Cylinders specified for doors in other sections.
C. Related Sections:
1. Division 08 Section “Hollow Metal Doors and Frames”.
2. Division 08 Section “Flush Wood Doors”.
3. Division 08 Section “Aluminum-Framed Entrances and Storefronts”.
D. Codes and References: Comply with the version year adopted by the Authority Having
Jurisdiction.
1. ANSI A117.1 - Accessible and Usable Buildings and Facilities.
2. ICC/IBC - International Building Code.
3. NFPA 70 - National Electrical Code.
4. NFPA 80 - Fire Doors and Windows.
5. NFPA 101 - Life Safety Code.
6. NFPA 105 - Installation of Smoke Door Assemblies.
7. State Building Codes, Local Amendments.
E. Standards: All hardware specified herein shall comply with the following industry standards as
applicable. Any undated reference to a standard shall be interpreted as referring to the latest edition
of that standard:
1. ANSI/BHMA Certified Product Standards - A156 Series.
2. UL10C - Positive Pressure Fire Tests of Door Assemblies.
3. ANSI/UL 294 - Access Control System Units.
4. UL 305 - Panic Hardware.
5. ANSI/UL 437- Key Locks.
1.3 SUBMITTALS
A. Product Data: Manufacturer's product data sheets including installation details, material
descriptions, dimensions of individual components and profiles, operational descriptions and finishes.
B. Door Hardware Schedule: Prepared by or under the supervision of supplier, detailing, fabrication
and assembly of door hardware, as well as procedures and diagrams. Coordinate the final Door
Hardware Schedule with doors, frames, and related work to ensure proper size, thickness, hand,
function, and finish of door hardware.
1. Format: Comply with scheduling sequence and vertical format in DHI's "Sequence and
Format for the Hardware Schedule."
2. Organization: Organize the Door Hardware Schedule into door hardware sets indicating
complete designations of every item required for each door or opening. Organize door hardware
sets in same order as in the Door Hardware Sets at the end of Part 3. Submittals that do not
follow the same format and order as the Door Hardware Sets will be rejected and subject to
resubmission.
3. Content: Include the following information:
a. Type, style, function, size, label, hand, and finish of each door hardware item.
b. Manufacturer of each item.
c. Fastenings and other pertinent information.
d. Location of door hardware set, cross-referenced to Drawings, both on floor plans and in
door and frame schedule.
e. Explanation of abbreviations, symbols, and codes contained in schedule.
f. Mounting locations for door hardware.
g. Door and frame sizes and materials.
h. Warranty information for each product.
4. Submittal Sequence: Submit the final Door Hardware Schedule at earliest possible date,
particularly where approval of the Door Hardware Schedule must precede fabrication of other
work that is critical in the Project construction schedule. Include Product Data, Samples, Shop
Drawings of other work affected by door hardware, and other information essential to the
coordinated review of the Door Hardware Schedule.
C. Shop Drawings: Details of electrified access control hardware indicating the following:
1. Wiring Diagrams: Upon receipt of approved schedules, submit detailed system wiring
diagrams for power, signaling, monitoring, communication, and control of the access control
system electrified hardware. Differentiate between manufacturer-installed and field-installed
wiring. Include the following:
a. Elevation diagram of each unique access controlled opening showing location and
interconnection of major system components with respect to their placement in the
respective door openings.
b. Complete (risers, point-to-point) access control system block wiring diagrams.
c. Wiring instructions for each electronic component scheduled herein.
2. Electrical Coordination: Coordinate with related sections the voltages and wiring details
required at electrically controlled and operated hardware openings.
PART 2 - PRODUCTS
2.1 BUTT HINGES
A. Hinges: ANSI/BHMA A156.1 butt hinges with number of hinge knuckles and other options as
specified in the Door Hardware Sets.
1. Quantity: Provide the following hinge quantity:
a. Two Hinges: For doors with heights up to 60 inches.
b. Three Hinges: For doors with heights 61 to 90 inches.
c. Four Hinges: For doors with heights 91 to 120 inches.
d. For doors with heights more than 120 inches, provide 4 hinges, plus 1 hinge for every 30
inches of door height greater than 120 inches.
2. Hinge Size: Provide the following, unless otherwise indicated, with hinge widths sized for door
thickness and clearances required:
a. Widths up to 3’0”: 4-1/2” standard or heavy weight as specified.
b. Sizes from 3’1” to 4’0”: 5” standard or heavy weight as specified.
3. Hinge Weight and Base Material: Unless otherwise indicated, provide the following:
a. Exterior Doors: Heavy weight, non-ferrous, ball bearing or oil impregnated bearing hinges
unless Hardware Sets indicate standard weight.
b. Interior Doors: Standard weight, steel, ball bearing or oil impregnated bearing hinges
unless Hardware Sets indicate heavy weight.
4. Hinge Options: Comply with the following:
a. Non-removable Pins: With the exception of electric through wire hinges, provide set screw
in hinge barrel that, when tightened into a groove in hinge pin, prevents removal of pin while
door is closed; for all out-swinging lockable doors.
5. Manufacturers:
a. McKinney (MK) - TA/T4A Series, 5-knuckle.
2.2 CYLINDERS AND KEYING
A. General: Cylinder manufacturer to have minimum (10) years experience designing secured master
key systems and have on record a published security keying system policy.
B. Cylinder Types: Original manufacturer cylinders able to supply the following cylinder formats and
types:
1. Threaded mortise cylinders with rings and cams to suit hardware application.
2. Rim cylinders with back plate, flat-type vertical or horizontal tailpiece, and raised trim ring.
3. Bored or cylindrical lock cylinders with tailpieces as required to suit locks.
4. Tubular deadlocks and other auxiliary locks.
5. Mortise and rim cylinder collars to be solid and recessed to allow the cylinder face to be flush
and be free spinning with matching finishes.
6. Keyway: Manufacturer’s Standard.
C. Keying System: Each type of lock and cylinders to be factory keyed.
1. Supplier shall conduct a "Keying Conference" to define and document keying system
instructions and requirements.
2. Furnish factory cut, nickel-silver large bow permanently inscribed with a visual key control
number as directed by Owner.
3. Existing System: Field verify and key cylinders to match Owner's existing system.
D. Key Quantity: Provide the following minimum number of keys:
1. Change Keys per Cylinder: Two (2)
2. Master Keys (per Master Key Level/Group): Five (5).
3. Construction Keys (where required): Ten (10).
E. Construction Keying: Provide construction master keyed cylinders.
F. Key Registration List (Bitting List):
1. Provide keying transcript list to Owner's representative in the proper format for importing into
key control software.
2. Provide transcript list in writing or electronic file as directed by the Owner.
2.3 MORTISE LOCKS AND LATCHING DEVICES
A. Mortise Locksets, Grade 1 (Heavy Duty): Provide ANSI/BHMA A156.13, Series 1000, Operational
Grade 1 Certified Products Directory (CPD) listed mortise locksets. Listed manufacturers shall meet all
functions and features as specified herein.
1. Manufacturers:
a. ASSA ABLOY ACCENTRA, formerly known as Yale (YA) - 8800FL Series.
b. dormakaba BEST (BE) - 45H Series.
2.4 CYLINDRICAL LOCKS AND LATCHING DEVICES
A. Cylindrical Locksets, Grade 1 (Commercial Duty): ANSI/BHMA A156.2, Series 4000, Operational
Grade 1 Certified Products Directory (CPD) listed cylindrical locksets. Listed manufacturers shall meet
all functions and features as specified herein.
1. Manufacturers:
a. ASSA ABLOY ACCENTRA, formerly known as Yale (YA) 4700LN Series.
B. Cylindrical Indicator Locksets, Grade 1 (Commercial Duty): ANSI/BHMA A156.2, Series 4000,
Operational Grade 1 Certified Products Directory (CPD) listed. Listed manufacturers shall meet all
functions and features as specified herein.
1. Provide locksets with functions and features as follows:
a. Visual status indicators in rose, displaying bold visuals for vacant or occupied lock status.
b. Meets ANSI/BHMA A156.41 for single motion egress.
c. Meets UL and CUL Standard 10C Positive Pressure, Fire Test of Door Assemblies with
levers that meet A117.1 Accessibility Code.
d. Three-year limited warranty.
2. Manufacturers:
a. ASSA ABLOY ACCENTRA, formerly known as Yale (YA) - YPL Series.
2.5 LOCK AND LATCH STRIKES
A. Strikes: Provide manufacturer's standard strike with strike box for each latch or lock bolt, with
curved lip extended to protect frame, finished to match door hardware set, unless otherwise indicated,
and as follows:
1. Flat-Lip Strikes: For locks with three-piece antifriction latchbolts, as recommended by
manufacturer.
2. Extra-Long-Lip Strikes: For locks used on frames with applied wood casing trim.
3. Aluminum-Frame Strike Box: Provide manufacturer's special strike box fabricated for
aluminum framing.
4. Double-lipped strikes: For locks at double acting doors. Furnish with retractable stop for
rescue hardware applications.
B. Standards: Comply with the following:
1. Strikes for Mortise Locks and Latches: BHMA A156.13.
2. Strikes for Bored Locks and Latches: BHMA A156.2.
3. Strikes for Auxiliary Deadlocks: BHMA A156.36.
PART 3 - EXECUTION
3.1 EXAMINATION
A. Examine scheduled openings, with Installer present, for compliance with requirements for
installation tolerances, labeled fire door assembly construction, wall and floor construction, and other
conditions affecting performance.
B. Notify architect of any discrepancies or conflicts between the door schedule, door types, drawings
and scheduled hardware. Proceed only after such discrepancies or conflicts have been resolved in
writing.
3.2 PREPARATION
A. Hollow Metal Doors and Frames: Comply with ANSI/DHI A115 series.
B. Wood Doors: Comply with ANSI/DHI A115-W series.
3.3 INSTALLATION
A. Install each item of mechanical and electromechanical hardware and access control equipment to
comply with manufacturer's written instructions and according to specifications.
1. Installers are to be trained and certified by the manufacturer on the proper installation and
adjustment of fire, life safety, and security products including: hanging devices; locking devices;
closing devices; and seals.
B. Mounting Heights: Mount door hardware units at heights indicated in following applicable
publications, unless specifically indicated or required to comply with governing regulations:
1. Standard Steel Doors and Frames: DHI's "Recommended Locations for Architectural
Hardware for Standard Steel Doors and Frames."
2. DHI TDH-007-20: Installation Guide for Doors and Hardware.
3. Where indicated to comply with accessibility requirements, comply with ANSI A117.1
"Accessibility Guidelines for Buildings and Facilities."
4. Provide blocking in drywall partitions where wall stops or other wall mounted hardware is
located.
C. Retrofitting: Install door hardware to comply with manufacturer's published templates and written
instructions. Where cutting and fitting are required to install door hardware onto or into surfaces that are
later to be painted or finished in another way, coordinate removal, storage, and reinstallation of surface
protective trim units with finishing work specified in Division 9 Sections. Do not install surface-mounted
items until finishes have been completed on substrates involved.
D. Push Plates and Door Pulls: When through-bolt fasteners are in the same location as a push plate,
countersink the fasteners flush with the door face allowing the push plate to sit flat against the door.
E. Thresholds: Set thresholds for exterior and acoustical doors in full bed of sealant complying with
requirements specified in Division 7 Section "Joint Sealants."
F. Storage: Provide a secure lock up for hardware delivered to the project but not yet installed.
Control the handling and installation of hardware items so that the completion of the work will not be
delayed by hardware losses before and after installation.
3.4 FIELD QUALITY CONTROL
A. Field Inspection (Punch Report): Reference Division 01 Sections “Closeout Procedures”. Produce
project punch report for each installed door opening indicating compliance with approved submittals
and verification hardware is properly installed, operating and adjusted. Include list of items to be
completed and corrected, indicating the reasons or deficiencies causing the Work to be incomplete or
rejected.
1. Organization of List: Include separate Door Opening and Deficiencies and Corrective Action
Lists organized by Mark, Opening Remarks and Comments, and related Opening Images and
Video Recordings.
3.5 ADJUSTING
A. Initial Adjustment: Adjust and check each operating item of door hardware and each door to ensure
proper operation or function of every unit. Replace units that cannot be adjusted to operate as intended.
Adjust door control devices to compensate for final operation of heating and ventilating equipment and
to comply with referenced accessibility requirements.
3.6 CLEANING AND PROTECTION
A. Protect all hardware stored on construction site in a covered and dry place. Protect exposed
hardware installed on doors during the construction phase. Install any and all hardware at the latest
possible time frame.
B. Clean adjacent surfaces soiled by door hardware installation.
C. Clean operating items as necessary to restore proper finish. Provide final protection and maintain
conditions that ensure door hardware is without damage or deterioration at time of owner occupancy.
3.7 DEMONSTRATION
A. Instruct Owner's maintenance personnel to adjust, operate, and maintain mechanical and
electromechanical door hardware.
3.8 DOOR HARDWARE SETS
A. The hardware sets represent the design intent and direction of the owner and architect. They are a
guideline only and should not be considered a detailed hardware schedule. Discrepancies, conflicting
hardware and missing items should be brought to the attention of the architect with corrections made
prior to the bidding process. Omitted items not included in a hardware set should be scheduled with the
appropriate additional hardware required for proper application and functionality.
1. Quantities listed are for each pair of doors, or for each single door.
2. The supplier is responsible for handing and sizing all products.
3. Where multiple options for a piece of hardware are given in a single line item, the supplier shall
provide the appropriate application for the opening.
4. At existing openings with new hardware the supplier shall field inspect existing conditions prior
to the submittal stage to verify the specified hardware will work as required. Provide alternate
solutions and proposals as needed.
B. Manufacturer’s Abbreviations:
1. MK - McKinney
2. YA - ASSA ABLOY ACCENTRA
3. HS - HES
4. RF - Rixson
5. RO - Rockwood
6. PE - Pemko
7. SU - Securitron
8. OT - Other
9. BE - BEST Locks & Closers
Reference Door schedule sheet for Door hardware sets.
D. Keying Schedule: After a keying meeting with the owner has taken place prepare a separate keying
schedule detailing final instructions. Submit the keying schedule in electronic format. Include keying
system explanation, door numbers, key set symbols, hardware set numbers and special instructions.
Owner must approve submitted keying schedule prior to the ordering of permanent cylinders/cores.
E. Informational Submittals:
1. Product Test Reports: Indicating compliance with cycle testing requirements, based on
evaluation of comprehensive tests performed by manufacturer and witnessed by a qualified
independent testing agency.
1.4 CLOSEOUT SUBMITTALS
A. Operating and Maintenance Manuals: Provide manufacturers operating and maintenance manuals
for each item comprising the complete door hardware installation in quantity as required in Division 01,
Closeout Procedures.
B. Project Record Documents: Provide record documentation of as-built door hardware sets in digital
format (.pdf, .docx, .xlsx, .csv) and as required in Division 01, Project Record Documents.
1.5 QUALITY ASSURANCE
A. Manufacturers Qualifications: Engage qualified manufacturers with a minimum 5 years of
documented experience in producing hardware and equipment similar to that indicated for this Project
and that have a proven record of successful in-service performance.
B. Certified Products: Where specified, products must maintain a current listing in the Builders
Hardware Manufacturers Association (BHMA) Certified Products Directory (CPD).
C. Installer Qualifications: A minimum 3 years documented experience installing both standard and
electrified door hardware similar in material, design, and extent to that indicated for this Project and
whose work has resulted in construction with a record of successful in-service performance.
D. Door Hardware Supplier Qualifications: Experienced commercial door hardware distributors with a
minimum 5 years documented experience supplying both mechanical and electromechanical hardware
installations comparable in material, design, and extent to that indicated for this Project. Supplier
recognized as a factory direct distributor by the manufacturers of the primary materials with a
warehousing facility in Project's vicinity. Supplier to have on staff a certified Architectural Hardware
Consultant (AHC) available during the course of the Work to consult with Contractor, Architect, and
Owner concerning both standard and electromechanical door hardware and keying.
E. Source Limitations: Obtain each type and variety of door hardware specified in this section from a
single source unless otherwise indicated.
1. Electrified modifications or enhancements made to a source manufacturer's product line by a
secondary or third party source will not be accepted.
2. Provide electromechanical door hardware from the same manufacturer as mechanical door
hardware, unless otherwise indicated.
F. Each unit to bear third party permanent label indicating compliance with the referenced testing
standards.
G. Keying Conference: Conduct conference to comply with requirements in Division 01 Section
"Project Meetings." Keying conference to incorporate the following criteria into the final keying schedule
document:
1. Function of building, purpose of each area and degree of security required.
2. Plans for existing and future key system expansion.
3. Requirements for key control storage and software.
4. Installation of permanent keys, cylinder cores and software.
5. Address and requirements for delivery of keys.
H. Pre-Submittal Conference: Conduct coordination conference in compliance with requirements in
Division 01 Section "Project Meetings" with attendance by representatives of Supplier(s), Installer(s),
and Contractor(s) to review proper methods and the procedures for receiving, handling, and installing
door hardware.
1. Prior to installation of door hardware, conduct a project specific training meeting to instruct the
installing contractors' personnel on the proper installation and adjustment of their respective
products. Product training to be attended by installers of door hardware (including
electromechanical hardware) for aluminum, hollow metal and wood doors. Training will include the
use of installation manuals, hardware schedules, templates and physical product samples as
required.
2. Inspect and discuss electrical roughing-in, power supply connections, and other preparatory
work performed by other trades.
3. Review sequence of operation narratives for each unique access controlled opening.
4. Review and finalize construction schedule and verify availability of materials.
5. Review the required inspecting, testing, commissioning, and demonstration procedures
I. At completion of installation, provide written documentation that components were applied
according to manufacturer's instructions and recommendations and according to approved schedule.
1.6 DELIVERY, STORAGE AND HANDLING
A. Inventory door hardware on receipt and provide secure lock-up and shelving for door hardware
delivered to Project site. Do not store electronic access control hardware, software or accessories at
Project site without prior authorization.
B. Tag each item or package separately with identification related to the final Door Hardware
Schedule, and include basic installation instructions with each item or package.
C. Deliver, as applicable, permanent keys, cylinders, cores, access control credentials, software and
related accessories directly to Owner via registered mail or overnight package service. Instructions for
delivery to the Owner shall be established at the "Keying Conference".
1.7 COORDINATION
A. Templates: Obtain and distribute to the parties involved templates for doors, frames, and other
work specified to be factory prepared for installing standard and electrified hardware. Check Shop
Drawings of other work to confirm that adequate provisions are made for locating and installing
hardware to comply with indicated requirements.
B. Door and Frame Preparation: Doors and corresponding frames are to be prepared, reinforced and
pre-wired (if applicable) to receive the installation of the specified electrified, monitoring, signaling and
access control system hardware without additional in-field modifications.
1.8 WARRANTY
A. General Warranty: Reference Division 01, General Requirements. Special warranties specified in
this Article shall not deprive Owner of other rights Owner may have under other provisions of the
Contract Documents and shall be in addition to, and run concurrent with, other warranties made by
Contractor under requirements of the Contract Documents.
B. Warranty Period: Written warranty, executed by manufacturer(s), agreeing to repair or replace
components of standard and electrified door hardware that fails in materials or workmanship within
specified warranty period after final acceptance by the Owner. Failures include, but are not limited to,
the following:
1. Structural failures including excessive deflection, cracking, or breakage.
2. Faulty operation of the hardware.
3. Deterioration of metals, metal finishes, and other materials beyond normal weathering.
4. Electrical component defects and failures within the systems operation.
C. Warranty Period: Unless otherwise indicated, warranty shall be one year from date of
Substantial Completion.
4. Dustproof Strikes: BHMA A156.16.
2.6 ELECTRIC STRIKES
A. Standard Electric Strikes: Electric strikes conforming to ANSI/BHMA A156.31, Grade 1, for use
on non-rated or fire rated openings. Strikes shall be of stainless steel construction tested to a
minimum of 1500 pounds of static strength and 70 foot-pounds of dynamic strength with a
minimum endurance of 1 million operating cycles. Provide strikes with 12 or 24 VDC capability, fail-
secure unless otherwise specified. Where specified provide latchbolt and latchbolt strike monitoring
indicating both the position of the latchbolt and locked condition of the strike.
1. Manufacturers:
a. HES (HS) - 1500/1600 Series.
b. Von Duprin (VD) - 6200/6400 Series.
B. Provide electric strikes with in-line power controller and surge suppressor by the same
manufacturer as the strike with the combined products having a five year warranty.
2.7 SURFACE DOOR CLOSERS
A. All door closers specified herein shall meet or exceed the following criteria:
1. General: Door closers to be from one manufacturer, matching in design and style, with the
same type door preparations and templates regardless of application or spring size. Closers to
be non-handed with full sized covers.
2. Standards: Closers to comply with UL-10C for Positive Pressure Fire Test and be U.L.
listed for use of fire rated doors.
3. Size of Units: Comply with manufacturer's written recommendations for sizing of door
closers depending on size of door, exposure to weather, and anticipated frequency of use.
Where closers are indicated for doors required to be accessible to the Americans with
Disabilities Act, provide units complying with ANSI ICC/A117.1.
4. Closer Arms: Provide heavy duty, forged steel closer arms unless otherwise indicated in
Hardware Sets.
5. Closers shall not be installed on exterior or corridor side of doors; where possible install
closers on door for optimum aesthetics.
6. Closer Accessories: Provide door closer accessories including custom templates, special
mounting brackets, spacers and drop plates as required for proper installation. Provide
through-bolt and security type fasteners as specified in the hardware sets.
B. Door Closers, Surface Mounted (Utility Grade): ANSI/BHMA 156.4, Grade 1 Certified Products
Directory (CPD) listed surface mounted, utility grade door closers with complete spring power
adjustment, sizes 1 thru 6. Closers to be rack and pinion type, cast aluminum case construction,
with adjustable backcheck, closing sweep, and latch speed control valves. Provide closer standard
packed for regular, top-jamb, and parallel arm type mounting applications.
1. Manufacturers:
a. ASSA ABLOY ACCENTRA, formerly known as Yale (YA) - 51BC Series.
b. LCN Closers (LC) - 1250 Series.
2.8 ARCHITECTURAL TRIM
A. Door Protective Trim
1. General: Door protective trim units to be of type and design as specified below or in the
Hardware Sets.
2. Size: Fabricate protection plates (kick, armor, or mop) not more than 2" less than door
width (LDW) on stop side of single doors and 1” LDW on stop side of pairs of doors, and
not more than 1" less than door width on pull side. Coordinate and provide proper width
and height as required where conflicting hardware dictates. Height to be as specified in the
Hardware Sets.
3. Where plates are applied to fire rated doors with the top of the plate more than 16” above
the bottom of the door, provide plates complying with NFPA 80. Consult manufacturer’s
catalog and template book for specific requirements for size and applications.
4. Protection Plates: ANSI/BHMA A156.6 protection plates (kick, armor, or mop), fabricated
from the following:
a. Stainless Steel: 300 grade, 050-inch thick.
5. Options and fasteners: Provide manufacturer's designated fastener type as specified in
the Hardware Sets. Provide countersunk screw holes.
6. Manufacturers:
a. Rockwood (RO).
2.9 DOOR STOPS AND HOLDERS
A. General: Door stops and holders to be of type and design as specified below or in the
Hardware Sets.
B. Door Stops and Bumpers: ANSI/BHMA A156.16, Grade 1 door stops and wall bumpers.
Provide wall bumpers, either convex or concave types with anchorage as indicated, unless floor or
other types of door stops are specified in Hardware Sets. Do not mount floor stops where they will
impede traffic. Where floor or wall bumpers are not appropriate, provide overhead type stops and
holders.
1. Manufacturers:
a. Rockwood (RO).
2.10 ARCHITECTURAL SEALS
A. General: Thresholds, weatherstripping, and gasket seals to be of type and design as specified
below or in the Hardware Sets. Provide continuous weatherstrip gasketing on exterior doors and
provide smoke, light, or sound gasketing on interior doors where indicated. At exterior applications
provide non-corrosive fasteners and elsewhere where indicated.
B. Smoke Labeled Gasketing: Assemblies complying with NFPA 105 that are listed and labeled
by a testing and inspecting agency acceptable to authorities having jurisdiction, for smoke control
ratings indicated, based on testing according to UL 1784.
1. Provide smoke labeled perimeter gasketing at all smoke labeled openings.
C. Fire Labeled Gasketing: Assemblies complying with NFPA 80 that are listed and labeled by a
testing and inspecting agency acceptable to authorities having jurisdiction, for fire ratings indicated,
based on testing according to UL-10C.
1. Provide intumescent seals as indicated to meet UL10C Standard for Positive Pressure
Fire Tests of Door Assemblies, and NFPA 252, Standard Methods of Fire Tests of Door
Assemblies.
D. Sound-Rated Gasketing: Assemblies that are listed and labeled by a testing and inspecting
agency, for sound ratings indicated.
E. Replaceable Seal Strips: Provide only those units where resilient or flexible seal strips are
easily replaceable and readily available from stocks maintained by manufacturer.
F. Manufacturers:
1. Pemko (PE).
2.11 FABRICATION
A. Fasteners: Provide door hardware manufactured to comply with published templates generally
prepared for machine, wood, and sheet metal screws. Provide screws according to manufacturers
recognized installation standards for application intended.
2.12 FINISHES
A. Standard: Designations used in the Hardware Sets and elsewhere indicate hardware finishes
complying with ANSI/BHMA A156.18, including coordination with traditional U.S. finishes indicated
by certain manufacturers for their products.
B. Provide quality of finish, including thickness of plating or coating (if any), composition,
hardness, and other qualities complying with manufacturer's standards, but in no case less than
specified by referenced standards for the applicable units of hardware
C. Protect mechanical finishes on exposed surfaces from damage by applying a strippable,
temporary protective covering before shipping.
SECTION 081113 - HOLLOW METAL DOORS AND FRAMES
PART 1 - GENERAL
1.1 RELATED DOCUMENTS
A. Drawings and general provisions of the Contract, including General and Supplementary Conditions and
Division 01 Specification Sections, apply to this Section.
1.2 SUMMARY
A. Section Includes:
1. Standard and custom hollow metal doors and frames.
2. Steel sidelight, borrowed lite and transom frames.
3. Louvers installed in hollow metal doors.
4. Light frames and glazing installed in hollow metal doors.
B. Related Sections:
1. Division 01 Section "General Conditions".
2. Division 04 Section "Unit Masonry" for embedding anchors for hollow metal work into masonry
construction.
3. Division 08 Section “Flush Wood Doors”.
4. Division 08 Section "Glazing" for glass view panels in hollow metal doors.
5. Division 08 Section "Door Hardware".
6. Division 08 Section "Access Control Hardware".
7. Division 09 Sections "Exterior Painting" and "Interior Painting" for field painting hollow metal
doors and frames.
C. Codes and References: Comply with the version year adopted by the Authority Having Jurisdiction.
1. ANSI/SDI A250.8 - Recommended Specifications for Standard Steel Doors and Frames.
2. ANSI/SDI A250.4 - Test Procedure and Acceptance Criteria for Physical Endurance for Steel
Doors, Frames, Frames Anchors and Hardware Reinforcing.
3. ANSI/SDI A250.6 - Recommended Practice for Hardware Reinforcing on Standard Steel
Doors and Frames.
4. ANSI/SDI A250.10 - Test Procedure and Acceptance Criteria for Prime Painted Steel Surfaces
for Steel Doors and Frames.
5. ANSI/SDI A250.11 - Recommended Erection Instructions for Steel Frames.
6. ASTM A1008 - Standard Specification for Steel Sheet, Cold-Rolled, Carbon, Structural, High-
Strength Low-Alloy and High-Strength Low-Alloy with Improved Formability.
7. ASTM A653 - Standard Specification for Steel Sheet, Zinc-Coated (Galvanized) or Zinc-Iron
Alloy-Coated (Galvannealed) by the Hot-Dip Process.
8. ASTM A924 - Standard Specification for General Requirements for Steel Sheet, Metallic-
Coated by the Hot-Dip Process.
9. ASTM C 1363 - Standard Test Method for Thermal Performance of Building Assemblies by
Means of a Hot Box Apparatus.
10. ANSI/BHMA A156.115 - Hardware Preparation in Steel Doors and Frames.
11. ANSI/SDI 122 - Installation and Troubleshooting Guide for Standard Steel Doors and Frames.
12. ANSI/NFPA 80 - Standard for Fire Doors and Fire Windows; National Fire Protection
Association.
13. ANSI/NFPA 105: Standard for the Installation of Smoke Door Assemblies.
14. NFPA 252 - Standard Methods of Fire Tests of Door Assemblies; National Fire Protection
Association.
15. UL 10C - Positive Pressure Fire Tests of Door Assemblies.
16. UL 1784 - Standard for Air Leakage Tests of Door Assemblies.
1.3 QUALITY ASSURANCE
A. Source Limitations: Obtain hollow metal doors and frames through one source from a single
manufacturer wherever possible.
B. Quality Standard: In addition to requirements specified, furnish SDI-Certified manufacturer products
that comply with ANSI/SDI A250.8, latest edition, "Recommended Specifications for Standard Steel Doors
and Frames".
C. Fire-Rated Door Assemblies: Assemblies complying with NFPA 80 that are listed and labeled by a
qualified testing agency, for fire-protection ratings indicated, based on testing at positive pressure according
to UL10C (neutral pressure at 40” above sill) or UL 10C.
1. Oversize Fire-Rated Door Assemblies Construction: For units exceeding sizes of tested
assemblies, attach construction label certifying doors are built to standard construction
requirements for tested and labeled fire rated door assemblies except for size.
2. Temperature-Rise Limit: Where indicated and at vertical exit enclosures (stairwell openings)
and exit passageways, provide doors that have a maximum transmitted temperature end point of
not more than 450 deg F (250 deg C) above ambient after 30 minutes of standard fire-test
exposure.
3. Smoke Control Door Assemblies: Comply with NFPA 105.
a. Smoke "S" Label: Doors to bear “S” label, and include smoke and draft control
gasketing applied to frame and on meeting stiles of pair doors.
D. Fire-Rated, Borrowed-Light Frame Assemblies: Assemblies complying with NFPA 80 that are listed
and labeled, by a testing and inspecting agency acceptable to authorities having jurisdiction, for fire-
protection ratings indicated, based on testing according to NFPA 257. Provide labeled glazing material.
E. Storm Shelter Openings: Provide complete door systems for hurricane or tornado storm shelters, and
other areas of refuge, complying and tested according to ICC 500 (2014/2020), ICC/NSSA Standard for the
Design and Construction of Storm Shelters.
1. Each unit to bear third party permanent label indicating compliance with the referenced testing
standards.
F. Pre-Submittal Conference: Conduct conference in compliance with requirements in Division 01 Section
"Project Meetings" with attendance by representatives of Supplier, Installer, and Contractor to review
proper methods and procedures for installing hollow metal doors and frames and to verify installation of
electrical knockout boxes and conduit at frames with electrified or access control hardware.
1.4 DELIVERY, STORAGE, AND HANDLING
A. Deliver hollow metal work palletized, wrapped, or crated to provide protection during transit and Project
site storage. Do not use non-vented plastic.
B. Deliver welded frames with two removable spreader bars across bottom of frames, tack welded to
jambs and mullions.
C. Store hollow metal work under cover at Project site. Place in stacks of five units maximum in a vertical
position with heads up, spaced by blocking, on minimum 4-inch high wood blocking. Do not store in a
manner that traps excess humidity.
1. Provide minimum 1/4-inch space between each stacked door to permit air circulation. Door
and frames to be stacked in a vertical upright position.
1.5 PROJECT CONDITIONS
A. Field Measurements: Verify actual dimensions of openings by field measurements before fabrication.
1.6 COORDINATION
A. Coordinate installation of anchorages for hollow metal frames. Furnish setting drawings, templates, and
directions for installing anchorages, including sleeves, concrete inserts, anchor bolts, and items with
integral anchors. Deliver such items to Project site in time for installation.
B. Building Information Modeling (BIM) Support: Utilize designated BIM software tools and obtain training
needed to successfully participate in the Project BIM processes. All technical disciplines are responsible for
the product data integration and data reliability of their Work into the coordinated BIM applications.
1.7 WARRANTY
A. Special Warranty: Manufacturer's standard form in which manufacturer agrees to repair or replace
doors that fail in materials or workmanship within specified warranty period.
B. Warranty includes installation and finishing that may be required due to repair or replacement of
defective doors.
PART 2 - PRODUCTS
2.1 MANUFACTURERS
A. Manufacturers: Subject to compliance with requirements, provide steel doors and frames from a SDI
Certified manufacturer:
1. CECO Door Products (C).
2. Curries Company (CU).
2.2 MATERIALS
A. Cold-Rolled Steel Sheet: ASTM A 1008/A 1008M, Commercial Steel (CS), Type B; suitable for
exposed applications.
B. Metallic-Coated Steel Sheet: ASTM A 653/A 653M, Commercial Steel (CS), Type B; with minimum
G60 (Z180) or A60 (ZF180) metallic coating.
C. Frame Anchors: ASTM A 653/A 653M, Commercial Steel (CS), Commercial Steel (CS), Type B; with
minimum G60 (Z180) or A60 (ZF180) metallic coating.
2.3 HOLLOW METAL DOORS
A. General: Provide 1-3/4 inch doors of design indicated, not less than thickness indicated; fabricated with
smooth surfaces, without visible joints or seams on exposed faces unless otherwise indicated. Comply with
ANSI/SDI A250.8 and ANSI/NAAMM HMMA 867.
B. Exterior Doors: Face sheets fabricated of commercial quality hot-dipped zinc coated steel that complies
with ASTM A 653/A 653M, Coating Designation A60. Provide doors complying with requirements indicated
below by referencing ANSI/SDI A250.8 for level and model and ANSI/SDI A250.4 for physical performance
level:
1. Design: Flush panel.
2. Core Construction: Manufacturer's standard polystyrene. Where indicated, provide doors
fabricated as thermal-rated assemblies with a minimum R-value of 2.8 or better.
3. Level/Model: Level 3 and Physical Performance Level A (Extra Heavy Duty), Minimum 16 gauge
(0.053-inch - 1.3-mm) thick steel, Model 2.
4. Top and Bottom Edges: Reinforce tops and bottoms of doors with a continuous steel channel not
less than 16 gauge, extending the full width of the door and welded to the face sheet. Doors with an
inverted top channel to include a steel closure channel, screw attached, with the web of the channel
flush with the face sheets of the door. Plastic or composite channel fillers are not acceptable.
5. Hinge Reinforcement: Minimum 7 gauge (3/16") plate 1-1/4" x 9" or minimum 14 gauge continuous
channel with pierced holes, drilled and tapped.
6. Hardware Reinforcements: Fabricate according to ANSI/SDI A250.6 with reinforcing plates from
same material as door face sheets.
C. Interior Doors: Face sheets fabricated of commercial quality cold rolled steel that complies with
ASTM A 1008/A 1008M. Provide doors complying with requirements indicated below by referencing
ANSI/SDI A250.8 for level and model and ANSI/SDI A250.4 for physical performance level:
1. Design: Flush panel.
2. Core Construction: Manufacturer's standard kraft-paper honeycomb, or one-piece polystyrene
core, securely bonded to both faces.
a. Fire Door Core: As required to provide fire-protection and temperature-rise ratings
indicated.
3. Level/Model: Level 2 and Physical Performance Level B (Heavy Duty), Minimum 18 gauge
(0.042-inch - 1.0-mm) thick steel, Model 2.
4. Top and Bottom Edges: Reinforce tops and bottoms of doors with a continuous steel channel
not less than 16 gauge, extending the full width of the door and welded to the face sheet.
5. Hinge Reinforcement: Minimum 7 gauge (3/16") plate 1-1/4" x 9" or minimum 14 gauge
continuous channel with pierced holes, drilled and tapped.
6. Hardware Reinforcements: Fabricate according to ANSI/SDI A250.6 with reinforcing plates
from same material as door face sheets.
D. Manufacturers Basis of Design:
1. Curries Company (CU) - Polystyrene Core - 707 Series.
2.4 HOLLOW METAL FRAMES
A. General: Comply with ANSI/SDI A250.8 and with details indicated for type and profile.
B. Exterior Frames: Fabricated of hot-dipped zinc coated steel that complies with ASTM A 653/A 653M,
Coating Designation A60.
1. Fabricate frames with mitered or coped corners. Profile as indicated on drawings.
2. Manufacturers Basis of Design:
a. Curries Company (CU) - M CM Series.
C. Interior Frames: Fabricated from cold-rolled steel sheet that complies with ASTM A 1008/A 1008M.
1. Fabricate frames with mitered or coped corners. Profile as indicated on drawings.
2. Manufacturers Basis of Design:
a. Curries Company (CU) - M Series.
D. Fire rated frames: Fabricate frames in accordance with NFPA 80, listed and labeled by a qualified
testing agency, for fire-protection ratings indicated.
E. Hardware Reinforcement: Fabricate according to ANSI/SDI A250.6 Table 4 with reinforcement plates
from same material as frames.
2.5 FRAME ANCHORS
A. Jamb Anchors:
1. Masonry Type: Adjustable strap-and-stirrup or T-shaped anchors to suit frame size, formed
from A60 metallic coated material, not less than 0.042 inch thick, with corrugated or perforated
straps not less than 2 inches wide by 10 inches long; or wire anchors not less than 0.177 inch
thick.
2. Stud Wall Type: Designed to engage stud and not less than 0.042 inch thick.
3. Compression Type for Drywall Slip-on (Knock-Down) Frames: Adjustable compression
anchors.
B. Floor Anchors: Floor anchors to be provided at each jamb, formed from A60 metallic coated material,
not less than 0.042 inches thick.
C. Mortar Guards: Formed from same material as frames, not less than 0.016 inches thick.
2.6 LOUVERS
A. Metal Louvers: Unless otherwise indicated provide louvers to meet the following requirements.
1. Blade Type: Vision proof inverted V or inverted Y.
2. Metal and Finish: Galvanized steel, 0.040 inch thick, factory primed for paint finish with baked
enamel or powder coated finish. Match pre-finished door paint color where applicable.
B. Louvers for Fire Rated Doors: Metal louvers with fusible link and closing device, listed and labeled for
use in doors with fire protection rating of 1-1/2 hours and less.
1. Manufacturers: Subject to compliance with requirements, provide louvers to meet rating
indicated.
2. Metal and Finish: Galvanized steel, 0.040 inch thick, factory primed for paint finish with baked
enamel or powder coated finish. Match pre-finished door paint color where applicable.
2.7 LIGHT OPENINGS AND GLAZING
A. Stops and Moldings: Provide stops and moldings around glazed lites where indicated. Form corners of
stops and moldings with butted or mitered hairline joints at fabricator’s shop. Fixed and removable stops to
allow multiple glazed lites each to be removed independently. Coordinate frame rabbet widths between
fixed and removable stops with the type of glazing and installation indicated.
B. Moldings for Glazed Lites in Doors and Loose Stops for Glazed Lites in Frames: Minimum 20 gauge
thick, fabricated from same material as door face sheet in which they are installed.
C. Fixed Frame Moldings: Formed integral with hollow metal frames, a minimum of 5/8 inch (16 mm) high
unless otherwise indicated. Provide fixed frame moldings and stops on outside of exterior and on secure
side of interior doors and frames.
D. Preformed Metal Frames for Light Openings: Manufacturer's standard frame formed of 0.048-inch-
thick, cold rolled steel sheet; with baked enamel or powder coated finish; and approved for use in doors of
fire protection rating indicated. Match pre-finished door paint color where applicable.
2.8 ACCESSORIES
A. Mullions and Transom Bars: Join to adjacent members by welding or rigid mechanical anchors.
B. Grout Guards: Formed from same material as frames, not less than 0.016 inches thick.
2.9 FABRICATION
A. Fabricate hollow metal work to be rigid and free of defects, warp, or buckle. Accurately form metal to
required sizes and profiles, with minimum radius for thickness of metal. Where practical, fit and assemble
units in manufacturer's plant. When shipping limitations so dictate, frames for large openings are to be
fabricated in sections for splicing or splining in the field by others.
B. Tolerances: Fabricate hollow metal work to tolerances indicated in ANSI/SDI A250.8.
C. Hollow Metal Frames:
1. Hardware Preparation: Factory prepare hollow metal work to receive template mortised
hardware; include cutouts, reinforcement, mortising, drilling, and tapping according to the Door
Hardware Schedule and templates furnished as specified in Division 08 Section "Door Hardware."
2. Locate hardware as indicated, or if not indicated, according to ANSI/SDI A250.8.
3. Reinforce doors and frames to receive non-template, mortised and surface mounted door
hardware.
4. Comply with applicable requirements in ANSI/SDI A250.6 and ANSI/DHI A115 Series
specifications for preparation of hollow metal work for hardware.
5. Coordinate locations of conduit and wiring boxes for electrical connections with Division 26
Sections.
2.10 STEEL FINISHES
A. Prime Finishes: Doors and frames to be cleaned, and chemically treated to insure maximum finish
paint adhesion. Surfaces of the door and frame exposed to view to receive a factory applied coat of rust
inhibiting shop primer.
1. Shop Primer: Manufacturer's standard, fast-curing, lead and chromate free primer
complying with ANSI/SDI A250.10 acceptance criteria; recommended by primer manufacturer
for substrate; and compatible with substrate and field-applied coatings.
PART 3 - EXECUTION
3.1 EXAMINATION
A. Examine substrates, areas, and conditions, with Installer present, for compliance with requirements for
installation tolerances and other conditions affecting performance of the Work.
B. General Contractor to verify the accuracy of dimensions given to the steel door and frame
manufacturer for existing openings or existing frames (strike height, hinge spacing, hinge back set, etc.).
C. Proceed with installation only after unsatisfactory conditions have been corrected.
3.2 PREPARATION
A. Remove welded in shipping spreaders installed at factory. Restore exposed finish by grinding, filling,
and dressing, as required to make repaired area smooth, flush, and invisible on exposed faces.
B. Prior to installation, adjust and securely brace welded hollow metal frames for square, level, twist, and
plumb condition.
C. Tolerances shall comply with SDI-117 "Manufacturing Tolerances Standard Steel Doors and Frames."
D. Drill and tap doors and frames to receive non-template, mortised, and surface-mounted door hardware.
E. Verify tolerances against manufacturers installations instructions for tornado and hurricane storm
shelter openings.
3.3 INSTALLATION
A. General: Install hollow metal work plumb, rigid, properly aligned, and securely fastened in place;
comply with Drawings and manufacturer's written instructions.
B. Hollow Metal Frames: Install hollow metal frames of size and profile indicated. Comply with
ANSI/SDI A250.11 and NFPA 80 at fire rated openings.
1. Set frames accurately in position, plumbed, leveled, aligned, and braced securely until
permanent anchors are set. After wall construction is complete and frames properly set and
secured, remove temporary braces, leaving surfaces smooth and undamaged. Shim as necessary
to comply with installation tolerances.
2. Floor Anchors: Provide floor anchors for each jamb and mullion that extends to floor, and
secure with post-installed expansion anchors.
3. Masonry Walls: Coordinate installation of frames to allow for solidly filling space between
frames and masonry with mortar.
4. Grout Requirements: Do not grout head of frames unless reinforcing has been installed in
head of frame. Do not grout vertical or horizontal closed mullion members.
C. Hollow Metal Doors: Fit hollow metal doors accurately in frames, within clearances specified below.
Shim as necessary.
1. Non-Fire-Rated Standard Steel Doors:
a. Jambs and Head: 1/8 inch plus or minus 1/16 inch.
b. Between Edges of Pairs of Doors: 1/8 inch plus or minus 1/16 inch.
c. Between Bottom of Door and Top of Threshold: Maximum 3/8 inch.
d. Between Bottom of Door and Top of Finish Floor (No Threshold): Maximum 3/4 inch.
2. Fire-Rated Doors: Install doors with clearances according to NFPA 80.
D. Field Glazing: Comply with installation requirements in Division 08 Section "Glazing" and with hollow
metal manufacturer's written instructions.
3.4 ADJUSTING AND CLEANING
A. Final Adjustments: Check and readjust operating hardware items immediately before final inspection.
Leave work in complete and proper operating condition. Remove and replace defective work, including
hollow metal work that is warped, bowed, or otherwise unacceptable.
B. Remove grout and other bonding material from hollow metal work immediately after installation.
C. Prime-Coat and Painted Finish Touchup: Immediately after erection, sand smooth rusted or damaged
areas of prime coat, or painted finishes, and apply touchup of compatible air drying, rust-inhibitive primer,
zinc rich primer (exterior and galvanized openings) or finish paint.
3.5 FIELD QUALITY CONTROL
A. Field Inspection (Punch Report): Reference Division 01 Sections “Closeout Procedures”. Produce
project punch report for each installed door opening indicating compliance with approved submittals and
verification hardware is properly installed, operating and adjusted. Include list of items to be completed and
corrected, indicating the reasons or deficiencies causing the Work to be incomplete or rejected.
1. Organization of List: Include separate Door Opening and Deficiencies and Corrective Action Lists
organized by Mark, Opening Remarks and Comments, and related Opening Images and Video
Recordings.
SECTION 081416 - FLUSH WOOD DOORS
PART 1 GENERAL
1.1 SECTION INCLUDES
A. Flush wood doors; flush configuration; non-rated and acoustical.
1.2 REFERENCE STANDARDS
A. AWI/AWMAC/WI (AWS) - Architectural Woodwork Standards; 2014, with Errata (2016).
B. NEMA LD 3 - High-Pressure Decorative Laminates; 2005.
C. UL 10C - Standard for Positive Pressure Fire Tests of Door Assemblies; Current Edition, Including
All Revisions.
1.3 SUBMITTALS
A. See Section 013000 - Administrative Requirements, for submittal procedures.
B. Product Data: Indicate door core materials and construction; veneer species, type and
characteristics.
C. Shop Drawings: Show doors and frames, elevations, sizes, types, swings, undercuts, beveling,
blocking for hardware, factory machining, factory finishing, cutouts for glazing and other details.
1. Provide information as required by AWI/AWMAC/WI (AWS).
D. Samples: Submit two samples of door construction, 8 by 10 inch in size cut from top corner of
door.
E. Certificate: Submit labels and certificates required by quality assurance and quality control
programs.
F. Manufacturer's Installation Instructions: Indicate special installation instructions.
G. Warranty, executed in Owner's name.
1.4 QUALITY ASSURANCE
A. Manufacturer Qualifications: Company specializing in manufacturing the products specified in this
section, with not less than three years of documented experience.
1. Company with at least one project within the past 5 years with value of woodwork within 20
percent of cost of woodwork for this project.
2. Accredited participant in the specified certification program prior to the commencement of
fabrication and throughout the duration of the project.
B. Installer Qualifications: Company specializing in performing work of the type specified in this
section, with not less than three years of documented experience.
C. Quality Certification:
1. Provide labels or certificates indicating that the installed work complies with AWI/AWMAC/WI
(AWS) requirements for grade or grades specified.
2. Provide designated labels on shop drawings as required by certification program.
3. Provide designated labels on installed products as required by certification program.
4. Submit certifications upon completion of installation that verifies this work is in compliance with
specified requirements.
1.5 DELIVERY, STORAGE, AND HANDLING
A. Package, deliver and store doors in accordance with specified quality standard.
B. Accept doors on site in manufacturer's packaging. Inspect for damage.
C. Protect doors with resilient packaging sealed with heat shrunk plastic. Do not store in damp or wet
areas; or in areas where sunlight might bleach veneer. Seal top and bottom edges with tinted
sealer if stored more than one week. Break seal on site to permit ventilation.
1.6 WARRANTY
A. See Section 017800 - Closeout Submittals, for additional warranty requirements.
B. Interior Doors: Provide manufacturer's warranty for the life of the installation.
C. Include coverage for delamination of veneer, warping beyond specified installation tolerances,
defective materials, and telegraphing core construction.
PART 2 PRODUCTS
2.1 MANUFACTURERS
A. High Pressure Decorative Laminate (HPDL) Faced Doors:
1. Ampco Products, HYPERLINK "http://www.ampco.com/#sle"Inc: www.ampco.com/#sle.
2. Poncraft D HYPERLINK "http://www.poncraft.com/#sle"oor Co: www.poncraft.com/#sle.
3. VT Industries, HYPERLINK "http://www.vtindustries.com/#sle"Inc: www.vtindustries.com/#sle.
4. Substitutions: See Section 016000 - Product Requirements.
2.2 DOORS AND PANELS
A. Doors: Refer to drawings for locations and additional requirements.
1. Quality Standard: Custom Grade, Extra Heavy Duty performance, in accordance with
AWI/AWMAC/WI (AWS), unless noted otherwise.
2. High Pressure Decorative Laminate (HPDL) Faced Doors: 5-ply unless otherwise indicated.
B. Interior Doors: 1-3/4 inches thick unless otherwise indicated; flush construction.
1. Provide solid core doors at each location.
2. Fire Rated Doors: Tested to ratings indicated on drawings in accordance with UL 10C -
Positive Pressure; Underwriters Laboratories Inc (UL) or Intertek/Warnock Hersey (WHI)
labeled without any visible seals when door is open.
3. High pressure decorative laminate (HPDL) finish as indicated on drawings.
2.3 DOOR AND PANEL CORES
A. Non-Rated Solid Core and 20 Minute Rated Doors: Type particleboard core (PC), plies and faces
as indicated.
B. Sound-Rated Doors: Equivalent to type, with particleboard core (PC) construction as required to
achieve STC rating specified; plies and faces as indicated above.
2.4 DOOR FACINGS
A. High Pressure Decorative Laminate (HPDL) Facing for Non-Fire-Rated Doors: NEMA LD 3, HGS;
Pattern as scheduled; finish as selected.
B. Facing Adhesive: Type I - waterproof.
2.5 DOOR CONSTRUCTION
A. Fabricate doors in accordance with door quality standard specified.
B. Cores Constructed with stiles and rails:
1. Provide solid blocks at lock edge and top of door for closer for hardware reinforcement.
C. Factory machine doors for hardware other than surface-mounted hardware, in accordance with
hardware requirements and dimensions.
D. Factory fit doors for frame opening dimensions identified on shop drawings, with edge
clearances in accordance with specified quality standard.
E. Provide edge clearances in accordance with the quality standard specified.
2.6 ACCESSORIES
A. Hollow Metal Door Frames: As specified in Section 081113.
B. Glazing: As specified in Section 088000.
C. Glazing Stops: Rolled steel channel shape, butted corners; prepared for countersink style
tamper proof screws.
D. Door Hardware: As specified in Section 087100.
PART 3 EXECUTION
3.1 EXAMINATION
A. Verify existing conditions before starting work.
B. Verify that opening sizes and tolerances are acceptable.
C. Do not install doors in frame openings that are not plumb or are out-of-tolerance for size or
alignment.
3.2 INSTALLATION
A. Install doors in accordance with manufacturer's instructions and specified quality standard.
B. Use machine tools to cut or drill for hardware.
C. Coordinate installation of doors with installation of frames and hardware.
D. Coordinate installation of glazing.
3.3 TOLERANCES
A. Conform to specified quality standard for fit and clearance tolerances.
B. Conform to specified quality standard for telegraphing, warp, and squareness.
3.4 ADJUSTING
A. Adjust doors for smooth and balanced door movement.
B. Adjust closers for full closure.
B. Wall and Ceiling Mounted Units: Factory fabricated door and frame, fully assembled units with
corner joints welded, filled and ground flush; square and without rack or warp; coordinate
requirements with type of installation assembly being used for each unit.
1. Door Style: Single thickness with rolled or turned in edges.
2. Frames: 16 gage, 0.0598 inch, minimum thickness.
3. Single Steel Sheet Door Panels: 1/16 inch, minimum thickness.
4. Steel Finish: Primed.
5. Primed and Factory Finish: Polyester powder coat; color .
6. Door/Panel Size: As indicated on the drawings.
7. Hardware:
a. Hinges for Non-Fire-Rated Units: Concealed, constant force closure spring type.
b. Latch/Lock: Screw driver slot for quarter turn cam latch.
c. Gasketing: Extruded neoprene, around perimeter of door panel.
PART 3 EXECUTION
3.1 EXAMINATION
A. Verify that rough openings are correctly sized and located.
B. Begin installation only after substrates have been properly prepared, and if the responsibility of
another installer, notify Architect of unsatisfactory preparation before proceeding.
3.2 PREPARATION
A. Clean surfaces thoroughly prior to proceeding with this work.
B. Prepare surfaces using methods recommended by manufacturer for applicable substrates in
accordance with project conditions.
3.3 INSTALLATION
A. Install units in accordance with manufacturer's instructions.
B. Install frames plumb and level in openings, and secure units rigidly in place.
C. Position units to provide convenient access to concealed equipment when necessary.
SECTION 083100 - ACCESS DOORS AND PANELS
PART 1 GENERAL
1.1 SECTION INCLUDES
A. Wall and ceiling access door and frame units.
1.2 SUBMITTALS
A. See Section 013000 - Administrative Requirements, for submittal procedures.
B. Product Data: Provide sizes, types, finishes, hardware, scheduled locations, and details of
adjoining work.
C. Shop Drawings: Indicate exact position of each access door and/or panel unit.
D. Manufacturer's Installation Instructions: Indicate installation requirements.
E. Project Record Documents: Record actual locations of each access unit.\
1.3 QUALITY ASSURANCE
A. Manufacturer Qualifications: Company specializing in manufacturing the products specified in
this section with minimum three years documented experience.
B. Installer Qualifications: Company specializing in performing work of the type specified and with
at least three years documented experience.
PART 2 PRODUCTS
2.1 ACCESS DOORS AND PANELS ASSEMBLIES
A. Wall-Mounted Units:
1. Location: As indicated on drawings.
2. Material: Steel, hot-dipped zinc or zinc-aluminum-alloy coated.
3. Door/Panel: Hinged, standard duty, with tool-operated spring or cam lock and no handle.
4. Gypsum Board Mounting Criteria: Provide drywall bead frame with door surface flush with
wall surface.
B. Wall-Mounted Units in Wet Areas:
1. Location: As indicated on drawings.
2. Material: Stainless steel.
3. Door/Panel: Hinged, standard duty, with tool-operated spring or cam lock and no handle.
4. Wall Mounting Criteria: Provide surface-mounted face frame and door surface flush with
frame surface.
C. Ceiling-Mounted Units:
1. Location: As indicated on drawings.
2. Material: Steel, hot-dipped zinc, or zinc-aluminum-alloy coated.
3. Door/Panel: Hinged, standard duty, with tool-operated spring or cam lock and no handle.
2.2 WALL AND CEILING MOUNTED UNITS
A. Manufacturers:
1. ACUDOR Products Inc: www.acudor.com/#sle.
2. Babcock-Davis: www.babcockdavis.com/#sle.
3. Karp Associates, Inc: www.karpinc.com/#sle.
4. Milcor, Inc: www.milcorinc.com/#sle.
5. Nystrom, Inc: www.nystrom.com/#sle.
6. Substitutions: See Section 016000 - Product Requirements.
SHEET NUMBER
4040 N CENTRAL EXPY,
SUITE 720
DALLAS, TEXAS 75204
t 314.302.6864
www.modusarchitecture.com
FOR INFORMATION
PURPOSES ONLY. NOT TO
BE USED IN ANY CAPACITY
FOR BIDDING, PERMITTING,
OR CONSTRUCTION
REVISIONS:
SHEET NAME
ISSUE DATE:
16
2
5
L
A
N
C
A
S
T
E
R
D
R
I
V
E
GR
A
P
E
V
I
N
E
,
T
E
X
A
S
7
6
0
5
1
G132
SPECIFICATIONS
PE
R
M
I
T
S
E
T
CO
O
K
C
H
I
L
D
R
E
N
'
S
12/19/2024
M. Double stud at wall openings, door and window jambs, not more than 2 inches from each side of
openings.
N. Brace stud framing system rigid.
O. Coordinate erection of studs with requirements of door frames; install supports and attachments.
P. Coordinate installation of bucks, anchors, and blocking with electrical, mechanical, and other work
to be placed within or behind stud framing.
Q. Blocking: Use wood blocking secured to studs. Provide blocking for support of plumbing fixtures,
toilet partitions, wall cabinets, toilet accessories, hardware, and opening frames.
R. Sound Isolation Clips: Mechanically attach to framing or structure with fasteners recommended by
clip manufacturer. Install at spacing indicated on drawings.
S. Furring: Coordinate with sound isolation clip spacing and locations. Lap splices a minimum of 6
inches.
3.3 CEILING AND SOFFIT FRAMING
A. Comply with requirements of ASTM C754.
B. Install furring after work above ceiling or soffit is complete. Coordinate the location of hangers with
other work.
C. Install furring independent of walls, columns, and above-ceiling work.
D. Securely anchor hangers to structural members or embed in structural slab. Space hangers as
required to limit deflection to criteria indicated. Use rigid hangers at exterior soffits.
E. Space main carrying channels at maximum 72 inch on center, and not more than 6 inches from
wall surfaces. Lap splice securely.
F. Securely fix carrying channels to hangers to prevent turning or twisting and to transmit full load to
hangers.
G. Place furring channels perpendicular to carrying channels, not more than 2 inches from perimeter
walls, and rigidly secure. Lap splices securely.
H. Reinforce openings in suspension system that interrupt main carrying channels or furring
channels with lateral channel bracing. Extend bracing minimum 24 inches past each opening.
I. Laterally brace suspension system.
3.4 TOLERANCES
A. Maximum Variation From True Position: 1/8 inch in 10 feet.
B. Maximum Variation From Plumb: 1/8 inch in 10 feet.
SECTION 092216 - NON-STRUCTURAL METAL FRAMING
PART 1 GENERAL
1.1 SECTION INCLUDES
A. Metal partition, ceiling, and soffit framing.
B. Framing accessories.
1.2 RELATED REQUIREMENTS
A. Section 072100 - Thermal Insulation: Acoustic insulation.
1. REFERENCE STANDARDS
A. ASTM C645 - Standard Specification for Nonstructural Steel Framing Members; 2014, with
Editorial Revision (2015).
B. ASTM C754 - Standard Specification for Installation of Steel Framing Members to Receive
Screw-Attached Gypsum Panel Products; 2017.
C. ASTM C1002 - Standard Specification for Steel Self-Piercing Tapping Screws for Application of
Gypsum Panel Products or Metal Plaster Bases to Wood Studs or Steel Studs; 2016.
D. ASTM E90 - Standard Test Method for Laboratory Measurement of Airborne Sound
Transmission Loss of Building Partitions and Elements; 2009 (Reapproved 2016).
E. ASTM E413 - Classification for Rating Sound Insulation; 2016.
F. SSPC-Paint 20 - Zinc-Rich Primers (Type I, "Inorganic," and Type II, "Organic"); 2002 (Ed. 2004).
1.3 SUBMITTALS
A. See Section 013000 - Administrative Requirements, for submittal procedures.
B. Shop Drawings:
1. Indicate prefabricated work, component details, stud layout, framed openings, anchorage to
structure, acoustic details, type and location of fasteners, accessories, and items of other
related work.
2. Describe method for securing studs to tracks, splicing, and for blocking and reinforcement of
framing connections.
C. Product Data: Provide data describing framing member materials and finish, product criteria, load
charts, and limitations.
D. Product Data: Provide manufacturer's data on partition head to structure connectors, showing
compliance with requirements.
E. Manufacturer's Installation Instructions: Indicate special procedures and perimeter conditions
requiring special attention.
1.4 QUALITY ASSURANCE
A. Installer Qualifications: Company specializing in performing the work of this section with minimum
five years documented experience and approved by manufacturer.
1.5 MOCK-UP
A. Provide mock-up of stud wall, ceiling, and soffit framing including insulation, sheathing, window
frame, and door frame and finish specified in other sections. Coordinate with installation of
associated work specified in other sections.
1. Mock-up may remain as part of the Work.
PART 2 PRODUCTS
2.1 MANUFACTURERS
A. Metal Framing, Connectors, and Accessories:
1. CEMCO HYPERLINK "http://www.cemcosteel.com/#sle": www.cemcosteel.com/#sle.
2. ClarkDietrich Building System HYPERLINK "http://www.clarkdietrich.com/#sle"s:
www.clarkdietrich.com/#sle.
3. Mari HYPERLINK "http://www.marinoware.com/#sle"no: www.marinoware.com/#sle.
4. The Steel Network HYPERLINK "http://www.SteelNetwork.com/#sle", Inc:
www.SteelNetwork.com/#sle.
5. Substitutions: See Section 016000 - Product Requirements.
2.2 FRAMING MATERIALS
A. Fire Rated Assemblies: Comply with applicable code and as indicated on drawings.
B. Non-Loadbearing Framing System Components: ASTM C645; galvanized sheet steel, of size
and properties necessary to comply with ASTM C754 for the spacing indicated, with maximum
deflection of wall framing of L/240 at 5 psf.
1. Studs: C shaped with flat or formed webs with knurled faces.
2. Runners: U shaped, sized to match studs.
3. Ceiling Channels: C shaped.
4. Furring: Hat-shaped sections, minimum depth of 7/8 inch.
C. Ceiling Hangers: Type and size as specified in ASTM C754 for spacing required.
D. Partition Head to Structure Connections: Provide track fastened to structure with legs of sufficient
length to accommodate deflection, for friction fit of studs cut short and braced with continuous
bridging on both sides.
E. Deflection and Firestop Track: Intumescent strip factory-applied to track flanges expands when
exposed to heat or flames to provide a perimeter joint seal.
1. Products:
a. ClarkDietrich Building Systems; BlazeFrame Firestop Deflection Track: HYPERLINK
"http://www.clarkdietrich.com/#sle" www.clarkdietrich.com/#sle.
b. Substitutions: See Section 016000 - Product Requirements.
A. Preformed Top Track Firestop Seal:
1. Provide components UL-listed for use in UL-listed fire-rated head of partition joint systems
indicated on drawings.
2. Products:
a. Hilti, Inc; Top Track Seal CFS TTS HYPERLINK "http://www.us.hilti.com/#sle":
www.us.hilti.com/#sle.
b. Substitutions: See Section 016000 - Product Requirements.
B. Tracks and Runners: Same material and thickness as studs, bent leg retainer notched to receive
studs with provision for crimp locking to stud.
C. Furring and Bracing Members: Of same material as studs; thickness to suit purpose; complying
with applicable requirements of ASTM C754.
D. Fasteners: ASTM C1002 self-piercing tapping screws.
E. Sheet Metal Backing: 0.036 inch thick, galvanized.
F. Anchorage Devices: Powder actuated or Drilled expansion bolts.
G. Acoustic Insulation: As specified in Section 072100.
H. Acoustic Sealant: Acrylic emulsion latex or water-based elastomeric sealant; do not use solvent-
based non-curing butyl sealant.
I. Touch-Up Primer for Galvanized Surfaces: SSPC-Paint 20, Type I - Inorganic.
2.3 FABRICATION
A. Fabricate assemblies of framed sections to sizes and profiles required.
B. Fit, reinforce, and brace framing members to suit design requirements.
C. Fit and assemble in largest practical sections for delivery to site, ready for installation.
PART 3 EXECUTION
3.1 EXAMINATION
A. Verify existing conditions before starting work.
B. Verify that rough-in utilities are in proper location.
3.2 INSTALLATION OF STUD FRAMING
A. Comply with requirements of ASTM C754.
B. Extend partition framing to structure where indicated and to ceiling in other locations.
C. Partitions Terminating at Ceiling: Attach ceiling runner securely to ceiling track in accordance
with manufacturer's instructions.
D. Partitions Terminating at Structure: Attach extended leg top runner to structure, maintain
clearance between top of studs and structure, and brace both flanges of studs as indicated.
E. Align and secure top and bottom runners at 24 inches on center.
F. At partitions indicated with an acoustic rating:
1. Provide components and install as required to produce STC ratings as indicated, based on
published tests by manufacturer conducted in accordance with ASTM E90 with STC rating
calculated in accordance with ASTM E413.
2. Place one bead of acoustic sealant between runners and substrate, studs and adjacent
construction.
3. Place one bead of acoustic sealant between studs and adjacent vertical surfaces.
G. Fit runners under and above openings; secure intermediate studs to same spacing as wall studs.
H. Install studs vertically at spacing indicated on drawings.
I. Align stud web openings horizontally.
J. Secure studs to tracks using crimping method. Do not weld.
K. Stud splicing is not permissible.
L. Fabricate corners using a minimum of three studs.
SECTION 088000 - GLAZING
PART 1 GENERAL
1.1 SECTION INCLUDES
A. Insulating glass units.
B. Glazing compounds and accessories.
1.2 REFERENCE STANDARDS
A. 16 CFR 1201 - Safety Standard for Architectural Glazing Materials; current edition.
B. ANSI Z97.1 - American National Standard for Safety Glazing Materials Used in Buildings - Safety
Performance Specifications and Methods of Test; 2015.
C. ASTM C864 - Standard Specification for Dense Elastomeric Compression Seal Gaskets, Setting
Blocks, and Spacers; 2005 (Reapproved 2015).
D. ASTM C920 - Standard Specification for Elastomeric Joint Sealants; 2018.
E. ASTM C1036 - Standard Specification for Flat Glass; 2016.
F. ASTM C1048 - Standard Specification for Heat-Strengthened and Fully Tempered Flat Glass; 2012.
G. ASTM C1193 - Standard Guide for Use of Joint Sealants; 2016.
H. ASTM C1376 - Standard Specification for Pyrolytic and Vacuum Deposition Coatings on Flat Glass;
2015.
I. ASTM E1300 - Standard Practice for Determining Load Resistance of Glass in Buildings; 2016.
J. ASTM E2190 - Standard Specification for Insulating Glass Unit Performance and Evaluation; 2010.
K. GANA (GM) - GANA Glazing Manual; 2008.
L. GANA (SM) - GANA Sealant Manual; 2008.
M. NFRC 100 - Procedure for Determining Fenestration Product U-factors; 2017.
N. NFRC 200 - Procedure for Determining Fenestration Product Solar Heat Gain Coefficient and
Visible Transmittance at Normal Incidence; 2014, with Errata (2017).
O. NFRC 300 - Test Method for Determining the Solar Optical Properties of Glazing Materials and
Systems; 2017.
1.3 ADMINISTRATIVE REQUIREMENTS
A. Preinstallation Meeting: Convene a preinstallation meeting one week before starting work of this
section; require attendance by each of the affected installers.
1.4 SUBMITTALS
A. See Section 013000 - Administrative Requirements, for submittal procedures.
B. Product Data on Insulating Glass Unit and Glazing Unit Glazing Types: Provide structural, physical
and environmental characteristics, size limitations, special handling and installation requirements.
C. Product Data on Glazing Compounds and Accessories: Provide chemical, functional, and
environmental characteristics, limitations, special application requirements, and identify available
colors.
D. Samples: Submit two samples of glass units, showing coloration.
E. Certificate: Certify that products of this section meet or exceed specified requirements.
F. Warranty Documentation: Submit manufacturer warranty and ensure that forms have been
completed in Owner's name and registered with manufacturer.
1.5 QUALITY ASSURANCE
A. Perform Work in accordance with GANA (GM) for glazing installation methods. Maintain one copy
on site.
B. Manufacturer Qualifications: Company specializing in manufacturing the products specified in this
section with minimum three years of documented experience.
C. Installer Qualifications: Company specializing in performing work of the type specified and with at
least three years documented experience.
1.6 FIELD CONDITIONS
A. Do not install glazing when ambient temperature is less than 40 degrees F.
B. Maintain minimum ambient temperature before, during and 24 hours after installation of glazing
compounds.
1.7 WARRANTY
A. See Section 017800 - Closeout Submittals, for additional warranty requirements.
B. Insulating Glass Units: Provide a five (5) year manufacturer warranty to include coverage for seal
failure, interpane dusting or misting, including providing products to replace failed units.
PART 2 PRODUCTS
2.2 GLASS MATERIALS
A. Float Glass: Provide float glass based glazing unless noted otherwise.
1. Annealed Type: ASTM C1036, Type I - Transparent Flat, Class 1 - Clear, Quality-Q3.
2. Heat-Strengthened and Fully Tempered Types: ASTM C1048, Kind HS and FT where required
by code.
3. Fully Tempered Safety Glass: Complies with ANSI Z97.1 and 16 CFR 1201 criteria.
2.3 GLAZING COMPOUNDS
A. Polysulfide Sealant: Two component; chemical curing, non-sagging type; ASTM C920, Type M,
Grade NS, Class 25, Uses M, A, and G; with cured Shore A hardness range of 15 to 25; color as
selected.
B. Silicone Sealant: Single component; neutral curing; capable of water immersion without loss of
properties; non-bleeding, non-staining; ASTM C920, Type S, Grade NS, Class 25, Uses M, A, and
G; with cured Shore A hardness range of 15 to 25; color as selected.
2.4 ACCESSORIES
A. Setting Blocks: Silicone, with 80 to 90 Shore A durometer hardness; ASTM C864 Option II. Length
of 0.1 inch for each square foot of glazing or minimum 4 inch by width of glazing rabbet space minus
1/16 inch by height to suit glazing method and pane weight and area.
B. Spacer Shims: Neoprene, 50 to 60 Shore A durometer hardness; ASTM C864 Option II. Minimum 3
inch long by one half the height of the glazing stop by thickness to suit application, self adhesive on
one face.
C. Glazing Splines: Resilient silicone extruded shape to suit glazing channel retaining slot; ASTM C864
Option II; color black.
D. Glazing Clips: Manufacturer's standard type.
2.5 SOURCE QUALITY CONTROL
A. Provide shop inspection and testing for insulating glass.
PART 3 EXECUTION
3.1 VERIFICATION OF CONDITIONS
A. Verify that openings for glazing are correctly sized and within tolerances, including those for size,
squareness, and offsets at corners.
B. Verify that surfaces of glazing channels or recesses are clean, free of obstructions that may impede
moisture movement, weeps are clear, and support framing is ready to receive glazing system.
C. Verify that sealing between joints of glass framing members has been completed effectively.
D. Proceed with glazing system installation only after unsatisfactory conditions have been corrected.
3.2 PREPARATION
A. Clean contact surfaces with appropriate solvent and wipe dry within maximum of 24 hours before
glazing. Remove coatings that are not tightly bonded to substrates.
B. Seal porous glazing channels or recesses with substrate compatible primer or sealer.
C. Prime surfaces scheduled to receive sealant where required for proper sealant adhesion.
3.3 INSTALLATION, GENERAL
A. Install glazing in compliance with written instructions of glass, gaskets, and other glazing material
manufacturers, unless more stringent requirements are indicated, including those in glazing
referenced standards.
B. Install glazing sealants in accordance with ASTM C1193, GANA (SM), and manufacturer's
instructions.
3.4 INSTALLATION - DRY GLAZING METHOD (GASKET GLAZING)
A. Application - Exterior and/or Interior Glazed: Set glazing infills from either the exterior or the interior
of the building.
B. Place setting blocks at 1/4 points with edge block no more than 6 inch from corners.
C. Rest glazing on setting blocks and push against fixed stop with sufficient pressure on gasket to
attain full contact.
D. Install removable stops without displacing glazing gasket; exert pressure for full continuous contact.
3.5 INSTALLATION - WET GLAZING METHOD (COMPOUND AND COMPOUND)
A. Application - Interior Glazed: Set glazing infills from the interior of the building.
B. Install glazing resting on setting blocks. Install applied stop and center pane by use of spacer shims
at 24 inch centers, kept 1/4 inch below sight line.
C. Locate and secure glazing pane using glazers' clips.
D. Fill gaps between glazing and stops with glazing compound until flush with sight line. Tool surface to
straight line.
3.6 FIELD QUALITY CONTROL
A. Glass and Glazing product manufacturers to provide field surveillance of the installation of their
products.
B. Monitor and report installation procedures and unacceptable conditions.
3.7 CLEANING
A. Remove excess glazing materials from finish surfaces immediately after application using solvents
or cleaners recommended by manufacturers.
B. Remove non-permanent labels immediately after glazing installation is complete.
C. Clean glass and adjacent surfaces after sealants are fully cured.
D. Clean glass on both exposed surfaces not more than 4 days prior to Date of Substantial Completion
in accordance with glass manufacturer's written recommendations.
3.8 PROTECTION
A. After installation, mark pane with an 'X' by using removable plastic tape or paste; do not mark heat
absorbing or reflective glass units.
B. Remove and replace glass that is damaged during construction period prior to Date of Substantial
Completion.
1.3 QUALITY ASSURANCE
A. Installer Qualifications: Company specializing in performing gypsum board installation and
finishing, with minimum three years of experience.
PART 2 PRODUCTS
2.1 BOARD MATERIALS
A. Manufacturers - Gypsum-Based Board:
1. American Gypsum Company: www.americangypsum.com/#sle.
2. CertainTeed Corporation: www.certainteed.com/#sle.
3. Georgia-Pacific Gypsum: www.gpgypsum.com/#sle.
4. National Gypsum Company: www.nationalgypsum.com/#sle.
5. USG Corporation: www.usg.com/#sle.
B. Gypsum Wallboard: Paper-faced gypsum panels as defined in ASTM C1396/C1396M; sizes to
minimize joints in place; ends square cut.
1. Application: Use for vertical surfaces, unless otherwise indicated.
2. At Assemblies Indicated with Fire-Rating: Use type required by indicated tested assembly; if
no tested assembly is indicated, use Type X board, UL or WH listed.
3. Thickness:
a. Vertical Surfaces: 5/8 inch.
C. Exterior Sheathing Board: Sizes to minimize joints in place; ends square cut.
1. Application: Exterior sheathing, unless otherwise indicated.
2. Mold Resistance: Score of 10, when tested in accordance with ASTM D3273.
3. Glass Mat Faced Sheathing: Glass mat faced gypsum substrate as defined in ASTM
C1177/C1177M.
4. Core Type: Type X, as indicated.
5. Type X Thickness: 5/8 inch.
6. Edges: Square.
7. Glass Mat Faced Products:
a. American Gypsum Company; M-Glass Exterior Sheathing Type X.
b. Georgia-Pacific Gypsum; DensGlass Fireguard Sheathing.
c. National Gypsum Company; Gold Bond eXP Sheathing.
d. Substitutions: See Section 016000 - Product Requirements.
2.2 ACCESSORIES
A. Water-Resistive Barrier: As specified in Section 072500.
B. Screws for Fastening of Gypsum Panel Products to Cold-Formed Steel Studs Less than 0.033
inch in Thickness and Wood Members: ASTM C1002; self-piercing tapping screws, corrosion
resistant.
C. Screws for Fastening of Gypsum Panel Products to Steel Members from 0.033 to 0.112 inch in
Thickness: ASTM C954; steel drill screws, corrosion resistant.
PART 3 EXECUTION
3.1 EXAMINATION
A. Verify that project conditions are appropriate for work of this section to commence.
3.2 BOARD INSTALLATION
A. Comply with ASTM C840, GA-216, and manufacturer's instructions. Install to minimize butt end
joints, especially in highly visible locations.
B. Single-Layer Non-Rated: Install gypsum board in most economical direction, with ends and
edges occurring over firm bearing.
C. Exterior Sheathing: Comply with ASTM C1280. Install sheathing vertically, with edges butted
tight and ends occurring over firm bearing.
1. Seal joints, cut edges, and holes with water-resistant sealant.
3.3 TOLERANCES
A. Maximum Variation of Finished Gypsum Board Surface from True Flatness: 1/8 inch in 10 feet in
any direction.
SECTION 092116 - GYPSUM BOARD ASSEMBLIES
PART 1 GENERAL
1.1 SECTION INCLUDES
A. Gypsum sheathing.
B. Gypsum wallboard.
1.2 REFERENCE STANDARDS
A. ASTM C645 - Standard Specification for Nonstructural Steel Framing Members; 2014, with
Editorial Revision (2015).
B. ASTM C754 - Standard Specification for Installation of Steel Framing Members to Receive
Screw-Attached Gypsum Panel Products; 2017.
C. ASTM C840 - Standard Specification for Application and Finishing of Gypsum Board; 2017a.
D. ASTM C954 - Standard Specification for Steel Drill Screws for the Application of Gypsum Panel
Products or Metal Plaster Bases to Steel Studs From 0.033 in. (0.84 mm) to 0.112 in. (2.84 mm)
in Thickness; 2015.
E. ASTM C1002 - Standard Specification for Steel Self-Piercing Tapping Screws for Application of
Gypsum Panel Products or Metal Plaster Bases to Wood Studs or Steel Studs; 2016.
F. ASTM C1177/C1177M - Standard Specification for Glass Mat Gypsum Substrate for Use as
Sheathing; 2013.
G. ASTM C1280 - Standard Specification for Application of Exterior Gypsum Panel Products for
Use as Sheathing; 2013a.
H. ASTM C1396/C1396M - Standard Specification for Gypsum Board; 2017.
I. ASTM D3273 - Standard Test Method for Resistance to Growth of Mold on the Surface of
Interior Coatings in an Environmental Chamber; 2016.
J. GA-216 - Application and Finishing of Gypsum Panel Products; 2016.
1. SUBMITTALS
A. See Section 013000 - Administrative Requirements, for submittal procedures.
B. Product Data: Provide data on metal framing, gypsum board, accessories, and joint finishing
system.
C. Test Reports: For stud framing products that do not comply with ASTM C645 or ASTM C754,
provide independent laboratory reports showing maximum stud heights at required spacings and
deflections.
SECTION 088300 -MIRRORS
PART 1 GENERAL
1.1 SECTION INCLUDES
A. Glass mirrors.
1. Tempered safety glass.
1.2 REFERENCE STANDARDS
A. ASTM C1048 -Standard Specification for Heat-Strengthened and Fully Tempered Flat Glass; 2012.
B. ASTM C1193 -Standard Guide for Use of Joint Sealants; 2016.
C. GANA (GM) -GANA Glazing Manual; 2008.
D. GANA (TIPS) -Mirrors: Handle with Extreme Care (Tips for the Professional on the Care and Handling
of Mirrors); 2011.
1.3 SUBMITTALS
A. See Section 013000 -Administrative Requirements, for submittal procedures.
B. Product Data on Mirror Types: Submit structural, physical and environmental characteristics, size
limitations, special handling and installation requirements.
C. Product Data on Glazing Compounds: Submit chemical, functional, and environmental characteristics,
limitations, special application requirements, and identify available colors.
D. Manufacturer's Certificate: Certify that mirrors, meets or exceeds specified requirements.
E. Warranty: Submit manufacturer warranty and ensure that forms have been completed in Owner's
name and registered with manufacturer.
1.4 QUALITY ASSURANCE
A. Perform Work in accordance with GANA (GM) for glazing installation methods.
B. Fabricate, store, transport, receive, install, and clean mirrors in accordance with recommendations of
GANA (TIPS).
1.5 FIELD CONITIONS
A. Do not install mirrors when ambient temperature is less than 50 degrees F.
B. Maintain minimum ambient temperature before, during and 24 hours after installation of glazing
compounds.
1.6 WARRANTY
A. See Section 017800 -Closeout Submittals, for additional warranty requirements.
B. Provide five year manufacturer warranty for reflective coating on mirrors and replacement of same.
PART 2 PRODUCTS
2.1 MANUFACTURERS
A. Mirrors:
1. Binswanger Mirror/ACI Distribution: www.binswangerglass.com/#sle.
2. Lenoir Mirror Co: www.lenoirmirror.com/#sle.
3. Trulite Glass and Aluminum Solutions: www.trulite.com/#sle.
4. Substitutions: See Section 016000 -Product Requirements.
2.2 MATERIALS
A. Mirror Design Criteria: Select materials and/or provide supports as required to limit mirror material
deflection to 1/200, or to the flexure limit of glass, with full recovery of glazing materials, whichever is
less.
B. Mirror Glass: Clear, tempered safety glass; ASTM C1048, with copper and silver coatings, and
protective overcoating.
1. Thickness: 1/4 inch.
2. Edges: Bevelled.
3. Size: As noted on drawings.
2.3 ACCESSORIES
A. Setting Blocks: Neoprene, 80 to 90 Shore A durometer hardness.
B. Spacer Shims: Neoprene, 50 to 60 Shore A durometer hardness.
C. Glazing Tape: Preformed butyl compound; 10 to 15 Shore A durometer hardness; on release paper.
D. Glazing Clips: Manufacturer's standard type.
E. Mirror Attachment Accessories: Stainless steel clips.
F. Mirror Adhesive: Silicone pre-polymer based, chemically compatible with mirror coating and wall
substrate.
1. Application Temperature: Minus 35 to 140 degrees F at contact surfaces.
G. Channel Frame: One piece, channel frame, stainless steel, Type 430, satin finish, 1/2 inch by 1/2 inch
by 3/8 inch deep with 90 degree mitered corners.
PART 3 EXECUTION
3.1 EXAMINATION
A. Verify that openings for mirrored glazing are correctly sized and within tolerance.
B. Verify that surfaces of mirror frames or recesses are clean, free of obstructions, and ready for
installation of mirrors.
3.2 PREPARATION
A. Clean contact surfaces with solvent and wipe dry.
B. Seal porous mirror frames or recesses with substrate compatible primer or sealer. Prime surfaces
scheduled to receive sealant.
C. Prepare installation in accordance with ASTM C1193 for solvent release sealants, and install sealant
in accordance with manufacturer's instructions.
3.3 INSTALLATION
A. Install mirrors in accordance with GANA (TIPS) and manufacturers recommendations.
B. Set mirrors plumb and level, and free of optical distortion.
C. Set mirrors with edge clearance free of surrounding construction including countertops or
backsplashes.
3.4 CLEANING
A. Remove wet glazing materials from finish surfaces.
B. Remove labels after work is complete.
C. Clean mirrors and adjacent surfaces.
E. Manufacturer's Certificate: Certify that products meet or exceed specified requirements.
F. Maintenance Data: Include recommended cleaning methods, cleaning materials, and stain removal
methods.
G. Maintenance Materials: Furnish the following for Owner's use in maintenance of project.
1. See Section 016000 - Product Requirements, for additional provisions.
2. Extra Tile: 1 percent of each size, color, and surface finish combination, but not less than one
box of each type.
1.5 QUALITY ASSURANCE
A. Manufacturer Qualifications: Company specializing in manufacturing the types of products specified
in this section, with minimum five years of documented experience.
B. Installer Qualifications: Company specializing in performing tile installation, with minimum of fiv e
years of documented experience.
1.6 MOCK-UP
A. See Section 014000 - Quality Requirements, for general requirements for mock-up.
B. Construct tile mock-up where indicated on drawings, incorporating all components specified for the
location.
1. Minimum size of mock-up is indicated on drawings.
2. Approved mock-up may remain as part of the Work.
1.7 DELIVERY, STORAGE, AND HANDLING
A. Protect adhesives from freezing or overheating in accordance with manufacturer's instructions.
1.8 FIELD CONDITIONS
A. Do not install solvent-based products in an unventilated environment.
B. Maintain ambient and substrate temperature of 50 degrees F during installation of mortar materials.
PART 2 PRODUCTS
2.1 TILE
A. Manufacturers:
1. Refer to Finish Legend.
2. Substitutions: See Section 016000 - Product Requirements.
B. Tile Products: As scheduled.
2.2 TRIM AND ACCESSORIES
A. Ceramic Trim: Matching bullnose, double bullnose, cove base, and cove ceramic shapes in sizes
coordinated with field tile.
1. Applications:
a. Open Edges: Bullnose.
b. Inside Corners: Jointed.
c. Floor to Wall Joints: Cove base.
2. Manufacturers: Same as for tile.
B. Non-Ceramic Trim: Satin natural anodized extruded aluminum, style and dimensions to suit
application, for setting using tile mortar or adhesive.
1. Applications:
a. Open edges of wall tile.
b. Open edges of floor tile.
c. Wall corners, outside and inside.
d. Transition between floor finishes of different heights.
e. Expansion and control joints, floor and wall.
f. Floor to wall joints.
g. Borders and other trim as indicated on drawings.
2. Manufacturers:
a. Schluter-Systems: HYPERLINK "http://www.schluter.com/#sle"www.schluter.com/#sle.
b. Substitutions: See Section 016000 - Product Requirements.
2.3 SETTING MATERIALS
A. Manufacturers:
1. ARDEX Engineered Ceme HYPERLINK "http://www.ardexamericas.com/#sle"nts:
www.ardexamericas.com/#sle.
2. Bostik HYPERLINK "http://www.bostik-us.com/#sle"Inc: www.bostik-us.com/#sle.
3. Custom Building Products HYPERLINK "http://www.custombuildingproducts.com/#sle":
www.custombuildingproducts.com/#sle.
4. LATICRETE International HYPERLINK "http://www.laticrete.com/#sle", Inc: www.laticrete.com/
#sle.
5. Merkrete, by Parex USA, Inc HYPERLINK "http://www.merkrete.com/#sle":
www.merkrete.com/#sle.
6. TEC, an H.B. Fuller Construction Products Bran HYPERLINK "http://www.tecspecialty.com/
#sle"d: www.tecspecialty.com/#sle.
7. Substitutions: See Section 016000 - Product Requirements.
B. Improved Latex-Portland Cement Mortar Bond Coat: ANSI A118.15.
1. Applications: Use this type of bond coat where indicated and where no other type of bond coat
is indicated.
2. Products:
a. ARDEX Engineered Cements; S HYPERLINK "http://www.ardexamericas.com/#sle"28:
www.ardexamericas.com/#sle.
b. Custom Building Products; Complete Contact-LFT Premium Rapid Setting Large Format
Tile Mortar, with Multi-Surface Bonding Prim HYPERLINK
"http://www.custombuildingproducts.com/#sle"er: www.custombuildingproducts.com/#sle.
c. LATICRETE International, Inc; LATICRETE 254 Platinum HYPERLINK
"http://www.laticrete.com/#sle": www.laticrete.com/#sle.
d. Substitutions: See Section 016000 - Product Requirements.
PART 3 EXECUTION
3.1 EXAMINATION
A. Verify that sub-floor surfaces are smooth and flat within the tolerances specified for that type of
work and are ready to receive tile.
B. Verify that wall surfaces are smooth and flat within the tolerances specified for that type of work,
are dust-free, and are ready to receive tile.
C. Verify that sub-floor surfaces are dust-free and free of substances that could impair bonding of
setting materials to sub-floor surfaces.
D. Verify that concrete sub-floor surfaces are ready for tile installation by testing for moisture emission
rate and alkalinity; obtain instructions if test results are not within limits recommended by tile
manufacturer and setting materials manufacturer.
E. Verify that required floor-mounted utilities are in correct location.
3.2 PREPARATION
A. Protect surrounding work from damage.
B. Vacuum clean surfaces and damp clean.
C. Seal substrate surface cracks with filler. Level existing substrate surfaces to acceptable flatness
tolerances.
D. Install backer board in accordance with ANSI A108.11 and board manufacturer's instructions. Tape
joints and corners, cover with skim coat of setting material to a feather edge.
E. Prepare substrate surfaces for adhesive installation in accordance with adhesive manufacturer's
instructions.
3.3 INSTALLATION - GENERAL
A. Install tile, thresholds, and stair treads and grout in accordance with applicable requirements of
ANSI A108.1a through ANSI A108.13, manufacturer's instructions, and TCNA (HB)
recommendations.
B. Lay tile to pattern indicated. Do not interrupt tile pattern through openings.
C. Cut and fit tile to penetrations through tile, leaving sealant joint space. Form corners and bases
neatly. Align floor joints.
D. Place tile joints uniform in width, subject to v ariance in tolerance allowed in tile size. Make grout
joints without voids, cracks, excess mortar or excess grout, or too little grout.
E. Form internal angles square and external angles bullnosed.
F. Install non-ceramic trim in accordance with manufacturer's instructions.
G. Sound tile after setting. Replace hollow sounding units.
H. Keep control and expansion joints free of mortar, grout, and adhesive.
I. Prior to grouting, allow installation to completely cure; minimum of 48 hours.
J. Grout tile joints unless otherwise indicated. Use standard grout unless otherwise indicated.
K. At changes in plane and tile-to-tile control joints, use tile sealant instead of grout, with either bond
breaker tape or backer rod as appropriate to prevent three-sided bonding.
3.4 INSTALLATION - FLOORS - THIN-SET METHODS
A. Over interior concrete substrates, install in accordance with TCNA (HB) Method F116, organic
adhesive, with standard grout, unless otherwise indicated.
1. Use uncoupling membrane under all tile unless other underlayment is indicated.
2. Where waterproofing membrane is indicated, install in accordance with TCNA (HB) Method
F122, with latex-Portland cement grout.
3. Where epoxy bond coat and grout are indicated, install in accordance with TCNA (HB) Method
F131.
3.5 CLEANING
A. Clean tile and grout surfaces.
3.6 PROTECTION
A. Do not permit traffic over finished floor surface for 4 days after installation.
SECTION 093000 - TILING
PART 1 GENERAL
1.1 SECTION INCLUDES
A. Ceramic and porcelain wall and floor tile.
B. Coated glass mat backer board as tile substrate.
C. Ceramic trim.
D. Non-ceramic trim.
1.2 REFERENCE STANDARDS
A. ANSI A108.1a - American National Standard Specifications for Installation of Ceramic Tile in the
Wet-Set Method, with Portland Cement Mortar; 2014.
B. ANSI A108.1b - American National Standard Specifications for Installation of Ceramic Tile on a
Cured Portland Cement Mortar Setting Bed with Dry-Set or Latex-Portland Cement Mortar; 1999
(Reaffirmed 2010).
C. ANSI A108.1c - Specifications for Contractors Option: Installation of Ceramic Tile in the Wet-Set
Method with Portland Cement Mortar or Installation of Ceramic Tile on a Cured Portland Cement
Mortar Bed with Dry-Set or Latex-Portland Cement; 1999 (Reaffirmed 2010).
D. ANSI A108.4 - American National Standard Specifications for Installation of Ceramic Tile with
Organic Adhesives or Water Cleanable Tile-Setting Epoxy Adhesive; 2009 (Revised).
E. ANSI A108.5 - American National Standard Specifications for Installation of Ceramic Tile with Dry-
Set Portland Cement Mortar or Latex-Portland Cement Mortar; 1999 (Reaffirmed 2010).
F. ANSI A108.6 - American National Standard Specifications for Installation of Ceramic Tile with
Chemical Resistant, Water Cleanable Tile-Setting and -Grouting Epoxy; 1999 (Reaffirmed 2010).
G. ANSI A108.8 - American National Standard Specifications for Installation of Ceramic Tile with
Chemical Resistant Furan Resin Mortar and Grout; 1999 (Reaffirmed 2010).
H. ANSI A108.9 - American National Standard Specifications for Installation of Ceramic Tile with
Modified Epoxy Emulsion Mortar/Grout; 1999 (Reaffirmed 2010).
I. ANSI A108.10 - American National Standard Specifications for Installation of Grout in Tilework;
1999 (Reaffirmed 2010).
J. ANSI A108.11 - American National Standard Specifications for Interior Installation of Cementitious
Backer Units; 2010 (Reaffirmed 2016).
K. ANSI A108.12 - American National Standard for Installation of Ceramic Tile with EGP (Exterior Glue
Plywood) Latex-Portland Cement Mortar; 1999 (Reaffirmed 2010).
L. ANSI A108.13 - American National Standard for Installation of Load Bearing, Bonded, Waterproof
Membranes for Thin-Set Ceramic Tile and Dimension Stone; 2005 (Reaffirmed 2010).
M. ANSI A118.3 - American National Standard Specifications for Chemical Resistant, Water Cleanable
Tile-Setting and -Grouting Epoxy and Water Cleanable Tile-Setting Epoxy Adhesive; 2013
(Revised).
N. ANSI A118.7 - American National Standard Specifications for High Performance Cement Grouts for
Tile Installation; 2010 (Reaffirmed 2016).
O. ANSI A118.10 - American National Standard Specifications for Load Bearing, Bonded, Waterproof
Membranes For Thin-Set Ceramic Tile And Dimension Stone Installation; 2014.
P. ANSI A118.12 - American National Standard Specifications for Crack Isolation Membranes for Thin-
Set Ceramic Tile and Dimension Stone Installation; 2014.
Q. ANSI A118.15 - American National Standard Specifications for Improved Modified Dry-Set Cement
Mortar; 2012.
R. ANSI A136.1 - American National Standard for Organic Adhesives for Installation of Ceramic Tile;
2008 (Reaffirmed 2013).
S. ASTM C1178/C1178M - Standard Specification for Coated Glass Mat Water-Resistant Gypsum
Backing Panel; 2013.
T. TCNA (HB) - Handbook for Ceramic, Glass, and Stone Tile Installation; 2017.
1.3 ADMINISTRATIVE REQUIREMENTS
A. Preinstallation Meeting: Convene a preinstallation meeting one week before starting work of this
section; require attendance by all affected installers.
1.4 SUBMITTALS
A. See Section 013000 - Administrative Requirements, for submittal procedures.
B. Product Data: Provide manufacturers' data sheets on tile, mortar, grout, and accessories. Include
instructions for using grouts and adhesives.
C. Shop Drawings: Indicate tile layout, patterns, color arrangement, perimeter conditions, junctions
with dissimilar materials, control and expansion joints, thresholds, ceramic accessories, and setting
details.
D. Samples: Mount tile and apply grout on two plywood panels, minimum 18 by 18 inches in size
illustrating pattern, color variations, and grout joint size variations.
2.4 GROUTS
A. Manufacturers:
1. ARDEX Engineered Ceme HYPERLINK "http://www.ardexamericas.com/#sle"nts:
www.ardexamericas.com/#sle.
2. Bostik HYPERLINK "http://www.bostik-us.com/#sle"Inc: www.bostik-us.com/#sle.
3. Custom Building Products HYPERLINK "http://www.custombuildingproducts.com/#sle":
www.custombuildingproducts.com/#sle.
4. LATICRETE International HYPERLINK "http://www.laticrete.com/#sle", Inc: www.laticrete.com/
#sle.
5. Merkrete, by Parex USA, Inc HYPERLINK "http://www.merkrete.com/#sle":
www.merkrete.com/#sle.
6. Substitutions: See Section 016000 - Product Requirements.
B. High Performance Polymer Modified Grout: ANSI A118.7 polymer modified cement grout.
1. Applications: Use this type of grout where indicated and where no other type of grout is
indicated.
2. Use sanded grout for joints 1/8 inch wide and larger; use unsanded grout for joints less than
1/8 inch wide.
3. Color(s): As selected by Architect from manufacturer's full line.
4. Products:
a. ARDEX Engineered Cements; ARDEX HYPERLINK "http://www.ardexamericas.com/
#sle"FL: www.ardexamericas.com/#sle.
b. Custom Building Products; Fusion Pro Single Component Grout: HYPERLINK
"http://www.custombuildingproducts.com/#sle" www.custombuildingproducts.com/#sle.
c. LATICRETE International, Inc; LATICRETE PERMACOLOR Gro HYPERLINK
"http://www.laticrete.com/#sle"ut: www.laticrete.com/#sle.
d. Merkrete, by Parex USA, Inc; Merkrete Pro Grout: HYPERLINK
"http://www.merkrete.com/#sle"www.merkrete.com/#sle.
e. Substitutions: See Section 016000 - Product Requirements.
C. Epoxy Grout: ANSI A118.3 chemical resistant and water-cleanable epoxy grout.
1. Applications: Where indicated.
2. Color(s): As selected by Architect from manufacturer's full line.
3. Products:
a. ARDEX Engineered Cements; ARDEX WA HYPERLINK "http://www.ardexamericas.com/
#sle": www.ardexamericas.com/#sle.
b. Custom Building Products; CEG-IG 100% Solids Industrial Grade Epoxy Grout:
HYPERLINK "http://www.custombuildingproducts.com/#sle"
www.custombuildingproducts.com/#sle.
c. LATICRETE International, Inc; LATICRETE SPECTRALOCK PRO Premium Grout:
HYPERLINK "http://www.laticrete.com/#sle" www.laticrete.com/#sle.
d. Merkrete, by Parex USA, Inc; Merkrete Pro Epoxy HYPERLINK "http://www.merkrete.com/
#sle": www.merkrete.com/#sle.
e. Substitutions: See Section 016000 - Product Requirements.
2.5 MAINTENANCE MATERIALS
A. Grout Sealer: Liquid-applied, moisture and stain protection for existing or new Portland cement
grout.
1. Composition: Water-based colorless silicone.
2. Products:
a. Merkrete, by Parex USA, Inc; Merkrete Grout Seale HYPERLINK
"http://www.merkrete.com/#sle"r: www.merkrete.com/#sle.
b. Substitutions: See Section 016000 - Product Requirements.
2.6 ACCESSORY MATERIALS
A. Concrete Floor Slab Crack Isolation Membrane: Material complying with ANSI A118.12; not
intended as waterproofing.
1. Type: Fluid-applied.
2. Thickness: 20 mils, maximum.
3. Crack Resistance: No failure at 1/16 inch gap, minimum.
4. Products:
a. LATICRETE International, Inc; LATICRETE Blue 92 Anti-Fracture Membrane: HYPERLINK
"http://www.laticrete.com/#sle" www.laticrete.com/#sle.
b. Merkrete, by Parex USA, Inc; Merkrete Fracture Gu HYPERLINK
"http://www.merkrete.com/#sle"ard: www.merkrete.com/#sle.
c. Substitutions: See Section 016000 - Product Requirements.
B. Waterproofing Membrane at Floors: Specifically designed for bonding to cementitious substrate
under thick mortar bed or thin-set tile; complying with ANSI A118.10.
1. Crack Resistance: No failure at 1/16 inch gap, minimum; comply with ANSI A118.12.
2. Fluid or Trowel Applied Type:
a. Material: Synthetic rubber or Acrylic.
b. Thickness: 25 mils, minimum, dry film thickness.
c. Products:
1. ARDEX Engineered Cements; ARDEX 8+ HYPERLINK
"http://www.ardexamericas.com/#sle"9: www.ardexamericas.com/#sle.
2. Custom Building Products; RedGard Crack Prevention and Waterproofing Membrane:
HYPERLINK "http://www.custombuildingproducts.com/#sle"
www.custombuildingproducts.com/#sle.
3. LATICRETE International, Inc; LATICRETE HYDRO BAN HYPERLINK
"http://www.laticrete.com/#sle": www.laticrete.com/#sle.
4. Merkrete, by Parex USA, Inc; Merkrete Hydro Guard 200 HYPERLINK
"http://www.merkrete.com/#sle"0: www.merkrete.com/#sle.
5. Substitutions: See Section 016000 - Product Requirements.
3. Bonded Sheet Membrane Type:
a. Material: Polyethylene sheet membrane with non-woven fabric laminated to both sides, 20
to 30 mils thick, nominal.
b. Products:
1. ARDEX Engineered Cements; ARDEX SK HYPERLINK
"http://www.ardexamericas.com/#sle"175: www.ardexamericas.com/#sle.
2. LATICRETE International, Inc; LATICRETE HYDRO BAN Sheet Membrane:
HYPERLINK "http://www.laticrete.com/#sle" www.laticrete.com/#sle.
3. Noble Company; NobleSeal TS HYPERLINK "http://www.noblecompany.com/#sle":
www.noblecompany.com/#sle.
4. Substitutions: See Section 016000 - Product Requirements.
C. Reinforcing Mesh: 2 by 2 inch size weave of 16/16 wire size; welded fabric, galvanized
D. Backer Board: Coated glass mat type complying with ASTM C1178/C1178M; inorganic fiberglass
mat on both surfaces and integral acrylic coating vapor retarder.
1. Fire Resistant Type: Type X core, thickness 5/8 inch.
E. Mesh Tape: 2 inch wide self-adhesive fiberglass mesh tape.
A. Organic Adhesive: ANSI A136.1, thinset mastic type.
1. Use Type I in areas subject to prolonged moisture exposure.
2. Products:
a. ARDEX Engineered Cements; ARDEX D1 HYPERLINK "http://www.ardexamericas.com/
#sle"4: www.ardexamericas.com/#sle.
b. Custom Building Products; ReliaBond Ceramic Tile Adhesive - Type 1: HYPERLINK
"http://www.custombuildingproducts.com/#sle" www.custombuildingproducts.com/#sle.
c. LATICRETE International, Inc; LATICRETE 15 Premium Mastic HYPERLINK
"http://www.laticrete.com/#sle": www.laticrete.com/#sle.
d. Merkrete, by Parex USA, Inc; Merkrete Merstik HYPERLINK "http://www.merkrete.com/
#sle": www.merkrete.com/#sle.
e. Substitutions: See Section 016000 - Product Requirements.
SHEET NUMBER
4040 N CENTRAL EXPY,
SUITE 720
DALLAS, TEXAS 75204
t 314.302.6864
www.modusarchitecture.com
FOR INFORMATION
PURPOSES ONLY. NOT TO
BE USED IN ANY CAPACITY
FOR BIDDING, PERMITTING,
OR CONSTRUCTION
REVISIONS:
SHEET NAME
ISSUE DATE:
16
2
5
L
A
N
C
A
S
T
E
R
D
R
I
V
E
GR
A
P
E
V
I
N
E
,
T
E
X
A
S
7
6
0
5
1
G133
SPECIFICATIONS
PE
R
M
I
T
S
E
T
CO
O
K
C
H
I
L
D
R
E
N
'
S
12/19/2024
PART 2 PRODUCTS
2.1 STAIR COVERING
A. Stair Treads: Rubber; full width and depth of stair tread in one piece; tapered thickness.
1. Manufacturers:
a. Roppe Corp HYPERLINK "http://www.roppe.com/#sle": www.roppe.com/#sle.
2. Critical Radiant Flux (CRF): Minimum 0.45 watt per square centimeter, when tested in
accordance with ASTM E648 or NFPA 253.
3. Nosing: Square.
4. Color: As indicated on drawings.
5. Acceptable Products: As scheduled.
B. Stair Stringers: Full height in one piece and in maximum available lengths, matching treads in
material and color.
1. Nominal Thickness: 0.080 inch.
.2.2 RESILIENT BASE
A. Resilient Base: ASTM F1861, Type TS rubber, vulcanized thermoset; top set Style B, Cove.
1. Manufacturers:
a. Johnsonite, a Tarkett Company HYPERLINK "http://www.johnsonite.com/#sle":
www.johnsonite.com/#sle.
b. Substitutions: See Section 016000 - Product Requirements.
2. Critical Radiant Flux (CRF): Minimum 0.45 watt per square centimeter, when tested in
accordance with ASTM E648 or NFPA 253.
3. Height: 4 inch.
4. Thickness: 0.125 inch.
5. Finish: Satin.
6. Color: As indicated on drawings.
7. Accessories: Premolded external corners and internal corners.
8. Acceptable Products: As scheduled.
2.3 ACCESSORIES
A. Subfloor Filler: White premix latex; type recommended by adhesive material manufacturer.
B. Primers and Adhesives: Waterproof; types recommended by flooring manufacturer.
C. Filler for Coved Base: Plastic.
PART 3 EXECUTION
3.1 EXAMINATION
A. Verify that surfaces are flat to tolerances acceptable to flooring manufacturer, free of cracks that
might telegraph through flooring, clean, dry, and free of curing compounds, surface hardeners, and
other chemicals that might interfere with bonding of flooring to substrate.
B. Verify that wall surfaces are smooth and flat within the tolerances specified for that type of work, are
dust-free, and are ready to receive resilient base.
3.2 PREPARATION
A. Prepare floor substrates as recommended by flooring and adhesive manufacturers.
B. Remove sub-floor ridges and bumps. Fill minor low spots, cracks, joints, holes, and other defects
with sub-floor filler to achieve smooth, flat, hard surface.
C. Prohibit traffic until filler is fully cured.
D. Clean substrate.
E. Apply primer as required to prevent "bleed-through" or interference with adhesion by substances
that cannot be removed.
3.3 INSTALLATION - GENERAL
A. Starting installation constitutes acceptance of sub-floor conditions.
B. Install in accordance with manufacturer's written instructions.
C. Spread only enough adhesive to permit installation of materials before initial set.
D. Fit joints and butt seams tightly.
E. Set flooring in place, press with heavy roller to attain full adhesion.
F. Where type of floor finish, pattern, or color are different on opposite sides of door, terminate flooring
under centerline of door.
3.4 INSTALLATION - RESILIENT BASE
A. Fit joints tightly and make vertical. Maintain minimum dimension of 18 inches between joints.
B. Miter internal corners. At external corners, use premolded units. At exposed ends, use premolded
units.
C. Install base on solid backing. Bond tightly to wall and floor surfaces.
D. Scribe and fit to door frames and other interruptions.
3.5 INSTALLATION - STAIR COVERINGS
A. Install stair coverings in one piece for full width and depth of tread.
B. Install stringers configured tightly to stair profile.
C. Adhere over entire surface. Fit accurately and securely.
3.6 CLEANING
A. Remove excess adhesive from floor, base, and wall surfaces without damage.
B. Clean in accordance with manufacturer's written instructions.
3.7 PROTECTION
A. Prohibit traffic on resilient flooring for 48 hours after installation.
SECTION 096500 - RESILIENT FLOORING
PART 1 GENERAL
1.1 SECTION INCLUDES
A. Resilient base.
B. Resilient stair accessories.
C. Installation accessories.
1.2 REFERENCE STANDARDS
A. ASTM E648 - Standard Test Method for Critical Radiant Flux of Floor-Covering Systems Using a
Radiant Heat Energy Source; 2017.
B. ASTM F1861 - Standard Specification for Resilient Wall Base; 2016.
C. NFPA 253 - Standard Method of Test for Critical Radiant Flux of Floor Covering Systems Using a
Radiant Heat Energy Source; 2015.
1.3 SUBMITTALS
A. See Section 013000 - Administrative Requirements, for submittal procedures.
B. Product Data: Provide data on specified products, describing physical and performance
characteristics; including sizes, patterns and colors available; and installation instructions.
C. Shop Drawings: Indicate floor patterns.
D. Verification Samples: Submit two samples, in size illustrating color and pattern for each resilient
flooring product specified.
1.4 QUALITY ASSURANCE
A. Manufacturer Qualifications: Company specializing in manufacturing specified flooring with minimum
three years documented experience.
B. Installer Qualifications: Company specializing in installing specified flooring with minimum three
years documented experience.
1.5 DELIVERY, STORAGE, AND HANDLING
A. Store all materials off of the floor in an acclimatized, weather-tight space.
B. Maintain temperature in storage area between 55 degrees F and 90 degrees F.
C. Protect roll materials from damage by storing on end.
D. Do not double stack pallets.
1.6 FIELD CONDITIONS
A. Store materials for not less than 48 hours prior to installation in area of installation at a temperature
of 70 degrees F to achieve temperature stability. Thereafter, maintain conditions above 55 degrees
F.
SECTION 096813 - TILE CARPETING
PART 1 GENERAL
1.1 SECTION INCLUDES
A. Carpet tile, fully adhered.
1.2 SUBMITTALS
A. See Section 013000 - Administrative Requirements, for submittal procedures.
B. Product Data: Provide data on specified products, describing physical and performance
characteristics; sizes, patterns, colors available, and method of installation.
C. Shop Drawings: Indicate layout of joints and direction of carpet pile.
D. Samples: Submit two carpet tiles illustrating color and pattern design for each carpet color selected.
E. Manufacturer's Installation Instructions: Indicate special procedures and perimeter conditions
requiring special attention.
F. Maintenance Data: Include maintenance procedures, recommended maintenance materials, and
suggested schedule for cleaning.
G. Maintenance Materials: Furnish the following for Owner's use in maintenance of project.
1. See Section 016000 - Product Requirements, for additional provisions.
2. Extra Carpet Tiles: Quantity equal to 5 percent of total installed of each color and pattern
installed.
1.3 QUALITY ASSURANCE
A. Manufacturer Qualifications: Company specializing in manufacturing specified carpet tile with
minimum three years documented experience.
B. Installer Qualifications: Company specializing in installing carpet tile with minimum three years
documented experience and approved by carpet tile manufacturer.
1.4 FIELD CONDITIONS
A. Store materials in area of installation for minimum period of 24 hours prior to installation.
1.5 ATTIC STOCK
A. Provide 10% attic stock for CPT.
PART 2 PRODUCTS
2.1 MATERIALS
A. Products:
1. As scheduled.
1. ACCESSORIES
A. Sub-Floor Filler: White premix latex; type recommended by flooring material manufacturer.
B. Edge Strips: Embossed aluminum, color as selected by Architect.
C. Carpet Tile Installation Tabs: Precut adhesive tabs to connect carpet tiles to produce a continuous
mat and adhere to subfloor.
1. Provide product acceptable to tile carpting manufacturer.
PART 3 EXECUTION
3.1 EXAMINATION
A. Verify that sub-floor surfaces are smooth and flat within tolerances specified for that type of work
and are ready to receive carpet tile.
B. Verify that sub-floor surfaces are dust-free and free of substances that could impair bonding of
adhesive materials to sub-floor surfaces.
C. Cementitious Sub-floor Surfaces: Verify that substrates are dry enough and ready for flooring
installation by testing for moisture and pH.
1. Test in accordance with ASTM F710.
2. Obtain instructions if test results are not within limits recommended by flooring material
manufacturer and adhesive materials manufacturer.
3.2 PREPARATION
A. Prepare floor substrates as recommended by flooring and adhesive manufacturers.
B. Remove sub-floor ridges and bumps. Fill minor or local low spots, cracks, joints, holes, and other
defects with sub-floor filler.
C. Apply, trowel, and float filler to achieve smooth, flat, hard surface. Prohibit traffic until filler is cured.
D. Vacuum clean substrate.
3.3 INSTALLATION
A. Starting installation constitutes acceptance of sub-floor conditions.
B. Install carpet tile in accordance with manufacturer's instructions.
C. Blend carpet from different cartons to ensure minimal variation in color match.
D. Cut carpet tile clean. Fit carpet tight to intersection with vertical surfaces without gaps.
E. Lay carpet tile in square pattern, with pile direction parallel to next unit, set parallel to building lines.
F. Adhere carpet tile to substrate in accordance with manufacturer's instructions.
G. Trim carpet tile neatly at walls and around interruptions.
H. Complete installation of edge strips, concealing exposed edges.
3.4 CLEANING
A. Remove excess adhesive without damage, from floor, base, and wall surfaces.
B. Clean and vacuum carpet surfaces.
SECTION 095100 - ACOUSTICAL CEILINGS
PART 1 GENERAL
1.1 SECTION INCLUDES
A. Suspended metal grid ceiling system.
B. Translucent stretched fabric ceiling panels.
C. Acoustical units.
1.2 REFERENCE STANDARDS
A. ASTM C635/C635M - Standard Specification for the Manufacture, Performance, and Testing of
Metal Suspension Systems for Acoustical Tile and Lay-in Panel Ceilings; 2017.
B. ASTM C636/C636M - Standard Practice for Installation of Metal Ceiling Suspension Systems for
Acoustical Tile and Lay-In Panels; 2013.
C. ASTM E580/E580M - Standard Practice for Installation of Ceiling Suspension Systems for
Acoustical Tile and Lay-in Panels in Areas Subject to Earthquake Ground Motions; 2017.
D. ASTM E1264 - Standard Classification for Acoustical Ceiling Products; 2014.
1.3 ADMINISTRATIVE REQUIREMENTS
A. Sequence work to ensure acoustical ceilings are not installed until building is enclosed, sufficient
heat is provided, dust generating activities have terminated, and overhead work is completed,
tested, and approved.
B. Do not install acoustical units until after interior wet work is dry.
1.4 SUBMITTALS
A. See Section 013000 - Administrative Requirements, for submittal procedures.
B. Shop Drawings: Indicate grid layout and related dimensioning.
C. Product Data: Provide data on suspension system components.
D. Samples: Submit two full size samples illustrating material and finish of acoustical units.
E. Samples: Submit two samples each, 8 inches long, of suspension system main runner.
F. Manufacturer's Installation Instructions: Indicate special procedures.
G. Maintenance Materials: Furnish the following for Owner's use in maintenance of project.
1. See Section 016000 - Product Requirements, for additional provisions.
2. Extra Acoustical Units: Quantity equal to 5 percent of total installed.
1.5 QUALITY ASSURANCE
A. Suspension System Manufacturer Qualifications: Company specializing in manufacturing the
products specified in this section with minimum three years documented experience.
B. Acoustical Unit Manufacturer Qualifications: Company specializing in manufacturing the products
specified in this section with minimum three years documented experience.
1.6 FIELD CONDITIONS
A. Maintain uniform temperature of minimum 60 degrees F, and maximum humidity of 40 percent
prior to, during, and after acoustical unit installation.
PART 2 PRODUCTS
2.1 MANUFACTURERS
A. Acoustic Tiles/Panels:
1. Armstrong World Industries, Inc HYPERLINK "http://www.armstrong.com/#sle" :
www.armstrong.com/#sle.
2. Substitutions: See Section 016000 - Product Requirements.
B. Suspension Systems:
1. Same as for acoustical units.
2. Rockfon, L HYPERLINK "http://www.rockfon.com/#sle" LC: www.rockfon.com/#sle.
3. Substitutions: See Section 016000 - Product Requirements.
C. Translucent Stretched Fabric Ceiling Panels:
1. Eco-Ceiling.
2. Substitutions: Not allowed.
2.2 ACOUSTICAL UNITS
A. Acoustical Units - General: ASTM E1264, Class A.
B. Acoustical Panels: Products as scheduled.
2.3 SUSPENSION SYSTEM(S)
A. Metal Suspension Systems - General: Complying with ASTM C635/C635M; die cut and
interlocking components, with stabilizer bars, clips, splices, perimeter moldings, and hold down
clips as required.
B. A. Exposed Steel Suspension System: Formed steel, commercial quality cold rolled; heavy-duty.
1. Profile: Tee; 15/16 inch wide face.
2. Construction: Double web.
3. Finish: White painted.
2.4 ACCESSORIES
A. Support Channels and Hangers: Galvanized steel; size and type to suit application, seismic
requirements, and ceiling system flatness requirement specified.
B. Perimeter Moldings: Same material and finish as grid.
1. At Exposed Grid: Provide L-shaped molding for mounting at same elevation as face of grid.
C. Touch-up Paint: Type and color to match acoustical and grid units.
PART 3 EXECUTION
3.1 EXAMINATION
A. Verify existing conditions before starting work.
B. Verify that layout of hangers will not interfere with other work.
3.2 INSTALLATION - SUSPENSION SYSTEM
A. Install suspension system in accordance with ASTM C636/C636M, ASTM E580/E580M, and
manufacturer's instructions and as supplemented in this section.
B. Rigidly secure system, including integral mechanical and electrical components, for maximum
deflection of 1:360.
C. Lay out system to a balanced grid design with edge units no less than 50 percent of acoustical unit
size.
D. Install after major above-ceiling work is complete. Coordinate the location of hangers with other
work.
E. Hang suspension system independent of walls, columns, ducts, pipes and conduit. Where carrying
members are spliced, avoid visible displacement of face plane of adjacent members.
F. Where ducts or other equipment prevent the regular spacing of hangers, reinforce the nearest
affected hangers and related carrying channels to span the extra distance.
G. Do not support components on main runners or cross runners if weight causes total dead load to
exceed deflection capability.
H. Support fixture loads using supplementary hangers located within 6 inches of each corner, or
support components independently.
I. Do not eccentrically load system or induce rotation of runners.
J. Perimeter Molding: Install at intersection of ceiling and vertical surfaces and at junctions with other
interruptions.
1. Use longest practical lengths.
2. Overlap and rivet corners.
3.3 INSTALLATION - ACOUSTICAL UNITS
A. Install acoustical units in accordance with manufacturer's instructions.
B. Fit acoustical units in place, free from damaged edges or other defects detrimental to appearance
and function.
C. Fit border trim neatly against abutting surfaces.
D. Install units after above-ceiling work is complete.
E. Install acoustical units level, in uniform plane, and free from twist, warp, and dents.
F. Cutting Acoustical Units:
1. Cut to fit irregular grid and perimeter edge trim.
2. Make field cut edges of same profile as factory edges.
G. Install hold-down clips on panels within 20 ft of an exterior door.
3.4 TOLERANCES
A. Maximum Variation from Flat and Level Surface: 1/8 inch in 10 feet.
B. Maximum Variation from Plumb of Grid Members Caused by Eccentric Loads: 2 degrees.
SECTION 097200 WALL COVERINGS
PART 1 GENERAL
1.1 SECTION INCLUDES
A. Surface preparation.
B. Wall covering for wall applications.
1.2 REFERENCE STANDARDS
A. ASTM E84 - Standard Test Method for Surface Burning Characteristics of Building Materials; 2017.
B. ASTM F793/F793M - Standard Classification of Wall Coverings by Use Characteristics; 2015.
1.3 SUBMITTALS
A. See Section 013000 - Administrative Requirements, for submittal procedures.
B. Product Data: Provide data on wall covering and adhesive.
C. Shop Drawings: Indicate wall elevations with seaming layout.
D. Samples: Submit two samples of wall covering in size illustrating color, finish, and texture.
E. Test Reports: Indicate verification of flame and smoke ratings, when tested by UL.
F. Manufacturer's Installation Instructions: Indicate special procedures.
G. Maintenance Data: Submit data on cleaning, touch-up, and repair of covered surfaces.
1.4 QUALITY ASSURANCE
A. Manufacturer Qualifications: Company specializing in manufacturing products specified in this
section with minimum three years of documented experience.
B. Installer Qualifications: Company specializing in performing work of the type specified and with at
least three years of documented experience.
1.5 MOCK-UP
A. Provide panel, 2 panel drops wide, full height, illustrating installed wall covering and joint seaming
technique.
B. Locate where directed.
C. Mock-up may remain as part of the Work.
1.6 DELIVERY, STORAGE, AND HANDLING
A. Inspect roll materials at arrival on site, to verify acceptability.
B. Protect packaged adhesive from temperature cycling and cold temperatures.
C. Do not store roll goods on end.
1.7 FIELD CONDITIONS
A. Do not apply materials when surface and ambient temperatures are outside the temperature ranges
required by the adhesive or wall covering product manufacturer.
B. Maintain these conditions 24 hours before, during, and after installation of adhesive and wall
covering.
C. Provide lighting level of 80 ft candles measured mid-height at substrate surfaces.
PART 2 PRODUCTS
2.1 WALL COVERINGS
A. General Requirements:
1. Surface Burning Characteristics: Flame spread/Smoke developed index of 25/50, maximum,
when tested in accordance with ASTM E84.
B. Wall Covering: Fabric-backed vinyl roll stock.
1. Conform to ASTM F793/F793M, Category V, Type II.
2. Provide digitally printed custom graphic wall covering on feature wall as indicated. Coordinate
with Architect.
3. Acceptable Products: As scheduled.
C. Wall Covering: Wood veneer.
1. Acceptable Products: As scheduled.
D. Adhesive: Type recommended by wall covering manufacturer to suit application to substrate.
E. Substrate Filler: As recommended by adhesive and wall covering manufacturers; compatible with
substrate.
PART 3 EXECUTION
3.1 EXAMINATION
A. Verify that substrate surfaces are prime painted and ready to receive work, and conform to
requirements of the wall covering manufacturer.
B. Measure moisture content of surfaces using an electronic moisture meter. Do not apply wall
coverings if moisture content of substrate exceeds level recommended by wall covering manufacturer.
C. Verify flatness tolerance of surfaces does not vary more than 1/8 inch in 10 feet nor vary at a rate
greater than 1/16 inch/ft.
3.2 PREPARATION
A. Fill cracks in substrate and smooth irregularities with filler; sand smooth.
B. Wash impervious surfaces with tetra-sodium phosphate, rinse and neutralize; wipe dry.
C. Surface Appurtenances: Remove or mask electrical plates, hardware, light fixture trim,
escutcheons, and fittings prior to preparing surfaces or finishing.
D. Surfaces: Correct defects and clean surfaces that affect work of this section. Remove existing
coatings that exhibit loose surface defects.
E. Marks: Seal with shellac those that may bleed through surface finishes.
F. Vacuum clean surfaces free of loose particles.
3.3 INSTALLATION
A. Apply adhesive and wall covering in accordance with manufacturer's instructions.
B. Apply adhesive to wall surface immediately prior to application of wall covering.
C. Razor trim edges on flat work table. Do not razor cut on gypsum board surfaces.
D. Apply wall covering smooth, without wrinkles, gaps or overlaps. Eliminate air pockets and ensure
full bond to substrate surface.
E. Butt edges tightly.
F. Horizontal seams are not acceptable.
G. Do not seam within 2 inches of internal corners or within 6 inches of external corners.
H. Install wall covering before installation of bases and items attached to or spaced slightly from wall
surface.
I. Do not install wall covering more than 1/4 inch below top of resilient base.
J. Cover spaces above and below windows, above doors, in pattern sequence from roll.
K. Where wall covering tucks into reveals, or metal wallboard or plaster stops, apply with contact
adhesive within 6 inches of wall covering termination. Ensure full contact bond.
L. Install termination trim.
M. Remove excess adhesive while wet from seam before proceeding to next wall covering sheet.
Wipe clean with dry cloth.
3.4 CLEANING
A. Clean wall coverings of excess adhesive, dust, dirt, and other contaminants.
B. Reinstall wall plates and accessories removed prior to work of this section.
3.5 PROTECTION
A. Do not permit construction activities at or near finished wall covering areas.
END OF SECTION
SECTION 099100 - PAINTING
PART 1 - GENERAL
1.1 SUMMARY
A. Related Documents: General and Supplementary Conditions of the Contract, Division 01 General
Requirements, and Drawings are applicable to this Section.
B. Section Includes:
1. Complete surface preparation and finishing for field application of coatings and requirements
for field finishing mechanical and electrical equipment.
2. Examine specifications for various other trades and their provisions regarding their painting.
Surfaces that are left unfinished by other sections of the specifications shall be painted or
finished as a part of this Section.
3. Colors, including deep tones, will be selected by the Architect. Number of colors to be used on
job will be determined by Architect.
1.2 SURFACES NOT TO RECEIVE FIELD FINISHING
A. Do not paint copper, bronze, chrome plated items, nickel, stainless steel, Monel metal, lead, face
brick, prefinished wall, ceiling, and floor coverings, items with factory applied final finish (except
where exposed on roofs and in finished spaces), elevator shafts, crawl spaces, chases, and
plenums above suspended ceilings unless otherwise specified or scheduled.
1.3 DEFINITIONS
A. Conform to ASTM D16 for interpretation of terms used in this Section.
1.4 QUALITY ASSURANCE
A. Product Manufacturer: Company specializing in manufacturing quality paint and finish products
with 3 years' experience.
B. Applicator: Company specializing in commercial painting and finishing with 2 years' experience.
C. Product Labels: Include manufacturer's name, type of paint, stock number, color and label analysis
on label of containers.
1.5 REGULATORY REQUIREMENTS
A. Conform to applicable building code for flame spread/fuel contribution/smoke development rating
requirements for finishes.
B. Comply with applicable city, county, state, and federal requirements and ordinances regarding
maximum VOC (Volatile Organic Compound) content of all coatings.
1.6 TESTS
A. Provide periodic testing with Wet Film Thickness gage to verify that proper thickness of finish
coatings are being applied.
1.7 SUBMITTALS
A. Provide product data describing physical performance criteria and composition on all finishing
products.
B. Submit 2 samples, 12 by 12 inches in size illustrating range of colors and textures selected for
each surface finishing product scheduled.
C. Submit certification from manufacturer of coatings listing all products proposed for each. Certify
that each product meets current applicable regulations and ordinances regarding maximum VOC
content.
1.8 FIELD SAMPLES
A. Provide field sample panel, 96 inches long by 96 inches wide, illustrating each coating color,
texture, and finish intended for use.
B. Locate where directed.
C. Accepted sample may remain as part of the Work.
1.9 DELIVERY, STORAGE, AND HANDLING
A. Deliver, store, and protect products under provisions of Division 01 section “Product
Requirements”
B. Deliver products to site in sealed and labeled containers; inspect to verify acceptance.
C. Container labeling to include manufacturer's name, type of paint, brand name, brand code,
coverage, surface preparation, drying time, cleanup, color designation, and instructions for mixing
and reducing.
D. Store paint materials at minimum ambient temperature of 45 degrees F and a maximum of 90
degrees F, in well-ventilated area, unless required otherwise by manufacturer's instructions.
E. Take precautionary measures to prevent fire hazards and spontaneous combustion.
1.10 ENVIRONMENTAL REQUIREMENTS
A. Do not apply materials when surface and ambient temperatures are outside the ranges required by
paint manufacturer.
B. Provide continuous ventilation and heating facilities to maintain surface and ambient temperatures
above 45 degrees F for 24 hours before, during, and 48 hours after application of finishes, unless
required otherwise by manufacturer's instructions.
C. Do not apply exterior coatings during rain or snow, or when relative humidity is above 75 percent,
unless required otherwise by manufacturer's instructions.
D. Minimum Application Temperatures for Latex Paints: 45 degrees F for interiors; 50 degrees F for
exterior; unless required otherwise by manufacturer's instructions.
E. Minimum Application Temperature for Varnish and Finishes: 65 degrees F for interior or exterior,
unless required otherwise by manufacturer's instructions.
F. Provide lighting level of 80 ft candles measured mid- height at substrate surface.
1.11 EXTRA STOCK
A. Provide a 5 gallon container of each color to Owner.
B. Label each container with color, color number, texture, and room locations, in addition to the
manufacturer's label.
C. Furnish under provisions of Section 017000.
1.12 SCAFFOLDS AND PROTECTION
A. Provide adequate safe ladders, scaffolds, and stages necessary to complete work.
B. Protect completed finish and paint work, and protect adjacent finish surfaces from paint splatter,
spills and stains. Use adequate drop cloths and masking procedures during progress of work.
1.13 PRECAUTIONS
A. Do not store paints, oils, thinners and other flammable items inside the building and shall be stored
in approved containers when not in actual use during the painting job. The fire hazard shall be kept
at a minimum.
B. Precaution shall be taken to protect the public and construction workers during the progress of the
work.
C. Furnish a temporary fire extinguisher of suitable chemicals and capacity, located near flammable
materials.
PART 2 - PRODUCTS
2.1 MANUFACTURERS
A. Acceptable Manufacturers: Subject to compliance with requirements indicated, provide products of
one of the following:
1. Sherwin-Williams.
2. P.P.G. Industries.
3. Behr Process Corporation (Behr).
B. Materials selected for coating systems for each type surface shall be product of a single
manufacturer unless otherwise specified. Secondary products such as linseed oil, turpentine and
shellacs shall be first quality products of a reputable manufacturer.
2.2 MATERIALS
A. Coatings: Ready mixed. Process pigments to a soft paste consistency, capable of being readily
and uniformly dispersed to a homogeneous coating with good flow and brushing properties;
capable of drying or curing free of streaks or sags.
B. Accessory Materials: Linseed oil, shellac, turpentine, paint thinners and other materials not
specifically indicated but required to achieve the finishes specified, of commercial quality.
C. Patching Materials: Latex filler.
2.3 FINISHES
A. Color and Sheen: As scheduled.
1. INTERIOR PAINT SCHEDULE
A. Drywall (Gypsum):
1. Acrylic Latex:
a. PPG Paints: 1 coat PPG Paints Speedhide Zero VOC Primer 6-4900XI, 2 coats PPG
Paints Speedhide Zero VOC. Sheen as indicated.
b. Sherwin-Williams: 1 coat High Build Latex Primer B28W8601, 2 coats Sherwin-Williams
c. ProMar 200 Zero VOC. Sheen as indicated.
d. Behr: 1 coat Behr Premium Plus Interior Drywall Primer 73, 2 coats Behr Pro i300 Interior
Paint. Sheen as indicated.
B. Galvanized Metal:
1. High Performance Coating, Water Based Acrylic
a. PPG Paints: 1 coat DEVFLEX Direct-to-Metal 4020 primer
1. Flat: 2 Coats DEVLFEX 4020 Primer/Finish.
2. Eggshell: 2 coats DEVFLEX High Performance WB Acrylic 4212 topcoat.
3. Semi-Gloss: 2 coats DEVFLEX High Performance WB Acrylic 4216 topcoat.
b. Sherwin-Williams:
1. Flat: 2 coats Sherwin-Williams Pro-Cryl Universal Primer B66-310 Series,
2. Eg-Shel 2 coats Sherwin-Williams Pro Industrial Acrylic Eg-Shel B66-660 Series.
3. Semi-Gloss 2 coats Sherwin-Williams Pro Industrial Acrylic Semi-Gloss B66-650
Series.
c. Behr: 1 coat Behr Premium Plus Multi-Surface Primer & Sealer 436.
1. Flat: 2 coats Premium Plus Ultra Interior Matte 1750 topcoat.
2. Eggshell: 2 coats Premium Plus Ultra Eggshell 2750 topcoat.
3. Semi-Gloss: 2 coats Direct To Metal Semi-Gloss 3200 topcoat.
C Shop Primed Ferrous Metal:
1. High Performance Coating, Water-Based Acrylic:
a. PPG Paints: Eggshell: 2 topcoats DEVFLEX High Performance WB Acrylic Eggshell 4212
over prepared substrate. Test for adhesion.
b. 2 topcoats Sherwin-Williams Pro Industrial Eg-Shel B66-660 Series.
c. Behr: Eggshell: 1 coat Premium Plus Multi-Surface Primer & Sealer, 2 coats Premium
Plus Ultra Eggshell 2750 topcoat.
H. Plaster Surfaces: Fill hairline cracks, small holes, and imperfections with latex patching plaster.
Make smooth and flush with adjacent surfaces. Wash and neutralize high alkali surfaces.
I. Uncoated Steel and Iron Surfaces: Remove grease, scale, dirt, and rust. Where heavy coatings of
scale are evident, remove by wire brushing or sandblasting; clean by washing with solvent. Apply a
treatment of phosphoric acid solution, ensuring weld joints, bolts, and nuts are similarly cleaned.
Spot prime paint after repairs.
J. Shop Primed Steel Surfaces: Sand and scrape to remove loose primer and rust. Feather edges to
make touch-up patches inconspicuous. Clean surfaces with solvent. Prime bare steel surfaces.
K. Interior Wood Items Scheduled to Receive Paint Finish: Wipe off dust and grit prior to priming. Seal
knots, pitch streaks, and sappy sections with sealer. Fill nail holes and cracks after primer has
dried; sand between coats.
L. Interior Wood Items Schedule to Receive Transparent Finish: Wipe off dust and grit prior to
sealing, seal knots, pitch streaks, and sappy sections with sealer. Fill nail holes and cracks after
sealer has dried; sand lightly between coats.
M. Exterior Wood Scheduled to Receive Transparent Finish: Remove dust, grit, and foreign matter;
seal knots, pitch streaks, and sappy sections with sealer. Fill nail holes with tinted exterior caulking
compound after sealer has been applied.
N. Shop Finished Items: Finish in accordance with AWI standards and guide lines.
O. Wood and Metal Doors Scheduled for Painting: Seal top and bottom edges with primer.
3.3 PROTECTION
A. Protect elements surrounding the work of this Section from damage or disfiguration.
B. Repair damage to other surfaces caused by work of this Section.
C. Furnish drop cloths, shields, and protective methods to prevent spray or droppings from disfiguring
other surfaces.
D. Remove empty paint containers from site.
3.4 APPLICATION
A. The intent of these Specifications is to produce the highest quality appearance of paint and finish
surfaces. Employ skilled mechanics only. The proper preparation of all surfaces will be strictly
enforced and wherever finished surfaces show any defects due to improper preparation,
workmanship, etc., the defects shall be removed and the work refinished at the expense of the
Contractor.
B. Apply products in accordance with manufacturer's instructions. Final finish coats shall have visual
evidence of solid hiding and uniform appearance, and shall be free and smooth of brush marks,
streaks, sags, runs, laps, or skipped areas.
C. Do not apply finishes to surfaces that are not dry.
D. Apply each coat to uniform finish and thickness.
E. Apply each coat of paint slightly darker than preceding coat unless otherwise approved.
F. Sand lightly between coats on wood and metal items to achieve required finish.
G. Allow applied coat to dry before next coat is applied.
H. Where clear finishes are required, tint fillers to match wood. Work fillers into the grain before set.
Wipe excess from surface.
I. Prime back surfaces of interior and exterior woodwork scheduled to be painted with primer paint.
J. Prime back surfaces of interior woodwork scheduled to receive stain or varnish finish with gloss
varnish reduced 25 percent with mineral spirits.
K. Edges of paint adjoining other materials or colors shall be sharp and clean with no overlapping.
3.5 FINISHING MECHANICAL AND ELECTRICAL EQUIPMENT
A. Paint all shop primed equipment. Paint shop prefinished items where exposed to view in finished
spaces. In mechanical rooms, repair shop pre-finished coatings which have been scratched or
otherwise damaged with identical touch-up paint. Sand prior to touching up as required.
B. Remove unfinished louvers, grilles, covers, and access panels on mechanical and electrical
components and paint separately.
C. Paint all grilles, registers, diffusers, and speaker grilles to match adjacent wall and ceiling surfaces,
except that factory pre-finished items need not be painted if installed in a suspended acoustical
ceiling system where the acoustical panels match the mechanical or electrical item color.
D. In all finished spaces, prime and paint exposed pipes, conduit, boxes, ducts, hangers, brackets,
collars and supports. Paint to match adjacent surfaces.
E. Repair or replace identification markings on mechanical or electrical equipment when painted
accidentally.
F. Paint interior surfaces of air ducts and convectors that are visible through grilles and louvers with
one coat of flat black paint, to limit of sight line. Paint dampers exposed behind louvers, grilles, and
convector to match face panels.
G. Paint all surfaces of plywood backboards for electrical and telephone equipment before installing
equipment.
H. Replace electrical plates, hardware, light fixture trim, and fittings removed prior to finishing.
I. Paint exposed air handlers, roof ventilators, goose necks, exhaust fans and other items on the roof
with 2 coats exterior enamel. Prepare surfaces in accordance with the base metal or primer as
specified herein.
J. Paint concrete support bases with gray floor deck enamel.
K. Pipe hangers and other supports need not be painted except where installed in crawl spaces,
where they shall be painted with a thick coat of asphaltic paint.
3.6 CLEANING/TOUCH-UP
A. As Work proceeds, promptly remove paint where spilled, splashed, or spattered.
B. During progress of Work maintain premises free of unnecessary accumulation of tools, equipment,
surplus materials, and debris.
C. Collect cotton waste, cloths, and material which may constitute a fire hazard, place in closed metal
containers and remove daily from site.
D. Spot painting will be allowed to correct soiled or damaged paint surfaces only when touch-up spot
will blend into surrounding finish and is invisible to normal viewing (as determined by the Architect).
Otherwise, re-coat entire section to corners or to a visible stopping point.
3.7 V.O.C. (VOLATILE ORGANIC COMPOUND) COMPLIANCE
A. Products listed in following schedule and/or substitutes proposed for use by Contractor must be
formulated to meet all applicable ordinances and regulations regarding maximum V.O.C. content.
Utilize products which have been specially formulated to meet such requirements.
PART 3 - EXECUTION
3.1 EXAMINATION
A. Verify that surfaces and substrate conditions are ready to receive work as instructed by the product
manufacturer.
B. Examine surfaces scheduled to be finished prior to commencement of work. Report to Architect
any condition that may potentially affect proper application.
C. Measure moisture content of surfaces using an electronic moisture meter. Do not apply finishes
unless moisture content of surfaces are below the following maximums
1. Plaster and Gypsum Wallboard: 12 percent.
2. Interior Located Wood: 15 percent, measured in accordance with ASTM D2016.
3. Exterior Located Wood: 15 percent, measured in accordance with ASTM D2016.
D. Test shop applied primers for compatibility with subsequent cover materials.
E. Beginning of installation means acceptance of existing surfaces and substrate.
3.2 PREPARATION
A. Remove electrical plates, hardware, light fixture trim, and fittings prior to preparing surfaces or
finishing.
B. Correct minor defects and clean surfaces which affect work of this Section. Remove existing
coatings which exhibit loose surface defects.
C. Shellac and seal marks which may bleed through surface finishes.
D. Impervious Surfaces: Remove mildew by scrubbing with solution of tri-sodium phosphate and
bleach. Rinse with clean water and allow surface to dry.
E. Insulated Coverings: Remove dirt, grease, and oil from canvas and cotton.
F. Gypsum Board Surfaces: Latex fill minor defects. Spot prime defects after repair.
G. Galvanized Surfaces: Remove surface contamination and oils and wash with solvent. Apply coat of
etching primer.
SHEET NUMBER
4040 N CENTRAL EXPY,
SUITE 720
DALLAS, TEXAS 75204
t 314.302.6864
www.modusarchitecture.com
FOR INFORMATION
PURPOSES ONLY. NOT TO
BE USED IN ANY CAPACITY
FOR BIDDING, PERMITTING,
OR CONSTRUCTION
REVISIONS:
SHEET NAME
ISSUE DATE:
16
2
5
L
A
N
C
A
S
T
E
R
D
R
I
V
E
GR
A
P
E
V
I
N
E
,
T
E
X
A
S
7
6
0
5
1
G134
SPECIFICATIONS
PE
R
M
I
T
S
E
T
CO
O
K
C
H
I
L
D
R
E
N
'
S
12/19/2024
SECTION 123600 - COUNTERTOPS
PART 1 GENERAL
1.1 SECTION INCLUDES
A. Countertops for architectural cabinet work.
1.2 REFERENCE STANDARDS
A. ANSI A208.2 - American National Standard for Medium Density Fiberboard for Interior Use;
2009.
B. ASTM E84 - Standard Test Method for Surface Burning Characteristics of Building Materials;
2017.
C. AWI (QCP) - Quality Certification Program; current editi HYPERLINK "http://www.awiqcp.org/"on
at www.awiqcp.org.
D. AWI/AWMAC/WI (AWS) - Architectural Woodwork Standards; 2014, with Errata (2016).
E. AWMAC/WI (NAAWS) - North American Architectural Woodwork Standards, U.S. Version 3.1;
2016, with Errata (2017).
F. ISFA 3-01 - Classification and Standards for Quartz Surfacing Material; 2013.
G. MIA (DSDM) - Dimensional Stone Design Manual, Version VIII; 2016.
H. NEMA LD 3 - High-Pressure Decorative Laminates; 2005.
I. PS 1 - Structural Plywood; 2009.
1.3 SUBMITTALS
A. See Section 013000 - Administrative Requirements, for submittal procedures.
B. Product Data: Manufacturer's data sheets on each product to be used, including:
1. Preparation instructions and recommendations.
2. Storage and handling requirements and recommendations.
3. Specimen warranty.
C. Shop Drawings: Complete details of materials and installation; combine with shop drawings of
cabinets and casework specified in other sections.
D. Verification Samples: For each finish product specified, minimum size 6 inches square,
representing actual product, color, and patterns.
E. Test Reports: Chemical resistance testing, showing compliance with specified requirements.
F. Certificate: Submit labels and certificates required by quality assurance and quality control
programs.
1.4 QUALITY ASSURANCE
A. Installer Qualifications: Company specializing in performing work of the type specified in this
section, with not less than three years of documented experience.
B. Quality Certification:
1. Comply with AWI (QCP) woodwork association quality certification service/program in
accordance with requirements for work specified in this sectio HYPERLINK
"http://www.awiqcp.org/#sle"n: www.awiqcp.org/#sle.
2. Provide labels or certificates indicating that the installed work complies with
AWI/AWMAC/WI (AWS) requirements for grade or grades specified.
3. Provide designated labels on shop drawings as required by certification program.
4. Provide designated labels on installed products as required by certification program.
5. Submit certifications upon completion of installation that verifies this work is in compliance
with specified requirements.
1.5 DELIVERY, STORAGE, AND HANDLING
A. Store products in manufacturer's unopened packaging until ready for installation.
B. Store and dispose of solvent-based materials, and materials used with solvent-based materials,
in accordance with requirements of local authorities having jurisdiction.
1.6 FIELD CONDITIONS
A. Maintain environmental conditions (temperature, humidity, and ventilation) within limits
recommended by manufacturer for optimum results. Do not install products under environmental
conditions outside manufacturer's absolute limits.
PART 2 PRODUCTS
2.1 COUNTERTOPS
A. Quality Standard: Custom Grade, in accordance with AWI/AWMAC/WI (AWS) or AWMAC/WI
(NAAWS), unless noted otherwise.
B. Plastic Laminate Countertops: Self-supporting high-pressure decorative laminate (HPDL) panel
with decorative surface over structural members.
1. Panels: Phenolic resin impregnated Kraft paper core with melamine impregnated decorative
surface papers; NEMA LD 3 Grade CGS.
a. Manufacturers:
1. Formica Corporatio HYPERLINK "http://www.formica.com/#sle"n:
www.formica.com/#sle.
b. Panel Thickness: 1 inch.
c. Surface Burning Characteristics: Flame spread index of 25, maximum; smoke
developed index of 450, maximum; when tested in accordance with ASTM E84.
d. Core Color: Brown.
e. Finish: Matte or suede, gloss rating of 5 to 20.
f. Surface Color and Pattern: As scheduled.
2. Exposed Edge Treatment: Square natural cut sanded and polished to semi-gloss sheen.
3. Back and End Splashes: Same material, same construction; minimum 4 inches high.
SECTION 122400 WINDOW SHADES
PART 1 GENERAL
1.1 SECTION INCLUDES
A. Window shades and accessories.
1.2 REFERENCE STANDARDS
A. NFPA 701 - Standard Methods of Fire Tests for Flame Propagation of Textiles and Films; 2015.
1.3 ADMINISTRATIVE REQUIREMENTS
A. Preinstallation Meeting: Convene one week prior to commencing work related to products of this
section; require attendance of all affected installers.
B. Sequencing:
1. Do not fabricate shades until field dimensions for each opening have been taken.
2. Do not install shades until final surface finishes and painting are complete.
1.4 SUBMITTALS
A. See Section 013000 - Administrative Requirements, for submittal procedures.
B. Product Data: Provide manufacturer's standard catalog pages and data sheets including
materials, finishes, fabrication details, dimensions, profiles, mounting requirements, and
accessories.
C. Shop Drawings: Include shade schedule indicating size, location and keys to details.
D. Shop Drawings - Motorized Shades: Provide schematic system riser diagram indicating
component interconnections. Include requirements for interface with other systems.
E. Certificates: Manufacturer's documentation that line voltage components are UL listed or UL
recognized.
F. Source Quality Control Submittals: Provide test reports indicating compliance with specified
fabric properties.
G. Selection Samples: Include fabric samples in full range of available colors and patterns.
1. Motorized Shades: Include finish selections for controls.
H. Verification Samples: Minimum size 6 inches square, representing actual materials, color and
pattern.
I. Manufacturer's Instructions: Include instructions for storage, handling, protection, examination,
preparation, and installation of product.
J. Project Record Documents: Record actual locations of control systems and show interconnecting
wiring.
K. Operation and Maintenance Data: List of all components with part numbers, sources of supply,
and operation and maintenance instructions; include copy of shop drawings.
L. Warranty: Submit sample of manufacturer's warranty and documentation of final executed
warranty completed in Owner's name and registered with manufacturer.
1.5 QUALITY ASSURANCE
A. Manufacturer Qualifications: Company specializing in manufacturing products specified in this
section, with not less than five years of documented experience.
B. Installer Qualifications: Company specializing in performing work of this type with minimum three
years of documented experience.
1.6 DELIVERY, STORAGE, AND HANDLING
A. Deliver shades in manufacturer's unopened packaging, labeled to identify each shade for each
opening.
B. Handle and store shades in accordance with manufacturer's recommendations.
1.7 FIELD CONDITIONS
A. Do not install products under environmental conditions outside manufacturer's absolute limits.
1.8 WARRANTY
A. See Section 017800 - Closeout Submittals, for additional warranty requirements.
B. Provide manufacturer's warranty from Date of Substantial Completion, covering the following:
1. Shade Hardware: One year.
2. Electric Motors: One year.
3. Fabric: One year.
4. Aluminum and Steel Coatings: One year.
PART 2 PRODUCTS
2.1 MANUFACTURERS
A. Manually Operated Roller Shades:
1. Archtiectural E Screen 7501, Hunter Douglas,
Finish: White pearl, 1% Openess
Note: 96" Railroaded on width no seam. Mount to underside of gypsum board soffit at
window opening. Do not mount to Window frame
B. Source Limitations: Furnish products produced by a single manufacturer and obtained from a
single supplier.
2.2 WINDOW SHADE APPLICATIONS
A. Interior Roller Shades: Sheer shades.
1. Type: Roll down, closed position is at window sill.
2. Fabric: As scheduled.
3. Color: As selected by Architect from manufacturer’s full range of colors.
4. Mounting: Inside (between jambs).
5. Operation: Manual.
2.3 ROLLER SHADES
A. Roller Shades: Fabric roller shades complete with mounting brackets, roller tubes, hembars,
hardware and accessories.
1. Drop: Regular roll.
2. Size: As indicated on drawings.
B. Fabric: Non-flammable, color-fast, impervious to heat and moisture, and able to retain its shape
under normal operation.
1. Sheer Shades: Reduce glare yet still reveal considerable details to the outside; no privacy;
Openness Factor greater than 1 percent.
2. Flammability: Pass NFPA 701 large and small tests.
C. Roller Tubes: As required for type of operation.
1. Material: Extruded aluminum or galvanized steel; as required for shade location.
2. Size: Manufacturer's standard, selected for suitability for installation conditions, span, and
weight of shades.
3. Fabric Attachment: Utilize extruded channel in tube to accept vinyl spline welded to fabric
edge.
D. Hembars: Designed for weight requirements and adaptation to uneven surfaces, to maintain
bottom of shade straight and flat.
1. Style: Exposed aluminum bottom bar, rectangular profile with closed ends, containing a
spline groove top to receive and secure fabric end.
2. Finish: Painted.
3. Color: As selected from manufacturer's standard colors.
E. Manual Operation for Interior Shades: Clutch operated continuous loop; beaded ball chain.
2.4 ACCESSORIES
A. Fascias: Size as required to conceal shade mounting.
1. Style: As selected by Architect from shade manufacturer’s full selection.
2. Material and Color: To match shade.
B. Brackets and Mounting Hardware: As recommended by manufacturer for mounting configuration
and span indicated.
C. Fasteners: Non-corrosive, and as recommended by shade manufacturer.
2.5 FABRICATION
A. Field measure finished openings prior to ordering or fabrication.
B. Fabricate shades to fit openings within specified tolerances.
1. Vertical Dimensions: Fill openings from head to sill with 1/2 inch space between bottom bar
and window stool.
2. Horizontal Dimensions - Inside Mounting: Provide symmetrical light gaps on both sides of
shade not to exceed 3/4 inch total.
C. Dimensional Tolerances: As recommended in writing by manufacturer.
D. At openings requiring continuous multiple shade units with separate rollers, locate roller joints at
window mullion centers; butt rollers end-to-end.
PART 3 EXECUTION
3.1 EXAMINATION
A. Examine finished openings for deficiencies that may preclude satisfactory installation.
B. If substrate preparation is the responsibility of another installer, notify Architect of unsatisfactory
preparation before proceeding.
C. Start of installation shall be considered acceptance of substrates.
3.2 PREPARATION
A. Prepare surfaces using methods recommended by manufacturer for achieving best result for
substrate under the project conditions.
B. Coordinate with window installation and placement of concealed blocking to support shades.
3.3 INSTALLATION
A. Install in accordance with manufacturer's instructions and approved shop drawings, using
mounting devices as indicated.
B. Installation Tolerances:
1. Inside Mounting: Maximum space between shade and jamb when closed of 1/16 inch.
2. Maximum Offset From Level: 1/16 inch.
C. Replace shades that exceed specified dimensional tolerances at no extra cost to Owner.
D. Adjust level, projection and shade centering from mounting bracket. Verify there is no telescoping
of shade fabric. Ensure smooth shade operation.
3.4 CLEANING
A. Clean soiled shades and exposed components as recommended by manufacturer.
B. Replace shades that cannot be cleaned to "like new" condition.
3.5 CLOSEOUT ACTIVITIES
A. See Section 017800 - Closeout Submittals, for closeout submittals.
B. See Section 017900 - Demonstration and Training, for additional requirements.
C. Demonstration: Demonstrate operation and maintenance of window shade system to Owner's
personnel.
3.6 PROTECTION
A. Protect installed products from subsequent construction operations.
B. Touch-up, repair or replace damaged products before Substantial Completion.
3.7 MAINTENANCE
A. See Section 017000 - Execution and Closeout Requirements, for additional requirements relating
to maintenance service.
END OF SECTION
SECTION 104400 - FIRE PROTECTION SPECIALTIES
PART 1 GENERAL
1.1 SECTION INCLUDES
A. Fire extinguishers.
B. Fire extinguisher cabinets.
C. Accessories.
1.2 REFERENCE STANDARDS
A. NFPA 10 - Standard for Portable Fire Extinguishers; 2017.
1.3 SUBMITTALS
A. See Section 013000 - Administrative Requirements, for submittal procedures.
B. Product Data: Provide extinguisher operational features.
C. Shop Drawings: Indicate locations of cabinets and cabinet physical dimensions.
D. Manufacturer's Installation Instructions: Indicate special criteria and wall opening coordination
requirements.
E. Manufacturer's Certificate: Certify that products meet or exceed specified requirements.
F. Maintenance Data: Include test, refill or recharge schedules and re-certification requirements.
1.4 FIELD CONDITIONS
A. Do not install extinguishers when ambient temperature may cause freezing of extinguisher
ingredients.
PART 2 PRODUCTS
2.1 MANUFACTURERS
A. Fire Extinguishers:
1. Ansul, a Tyco Business HYPERLINK "http://www.ansul.com/#sle": www.ansul.com/#sle.
2. Kidde, a unit of United Technologies C HYPERLINK "http://www.kidde.com/#sle"orp:
www.kidde.com/#sle.
3. Nystrom, Inc HYPERLINK "http://www.nystrom.com/#sle": www.nystrom.com/#sle.
4. Pyro-Chem, a Tyco Busines HYPERLINK "http://www.pyrochem.com/#sle"s:
www.pyrochem.com/#sle.
5. Substitutions: See Section 016000 - Product Requirements.
B. Fire Extinguisher Cabinets and Accessories:
1. Kidde, a unit of United Technologies C HYPERLINK "http://www.kidde.com/#sle"orp:
www.kidde.com/#sle.
2. Larsen's Manufacturing C HYPERLINK "http://www.larsensmfg.com/#sle"o:
www.larsensmfg.com/#sle.
3. Nystrom, Inc HYPERLINK "http://www.nystrom.com/#sle": www.nystrom.com/#sle.
4. Potter-Roem HYPERLINK "http://www.potterroemer.com/#sle"er: www.potterroemer.com/
#sle.
5. Substitutions: See Section 016000 - Product Requirements.
2.2 FIRE EXTINGUISHERS
A. Fire Extinguishers - General: Comply with product requirements of NFPA 10 and applicable
codes, whichever is more stringent.
B. Multipurpose Dry Chemical Type Fire Extinguishers: Carbon steel tank, with pressure gauge.
1. Class: A:B:C type.
2. Size: 5 pound.
3. Finish: Baked polyester powder coat, red color.
4. Temperature range: Minus 40 degrees F to 120 degrees F.
2.3 FIRE EXTINGUISHER CABINETS
A. Cabinet Construction: Non-fire rated.
1. Formed aluminium.
B. Cabinet Configuration: Recessed type.
1. Size to accommodate accessories.
2. Projected Trim: Returned to wall surface, with 2-1/2 inch projection, and 2 inch wide face.
3. Provide cabinet enclosure with right angle inside corners and seams, and with formed
perimeter trim.
C. Door: 0.036 inch metal thickness, reinforced for flatness and rigidity with nylon catch. Hinge
doors for 180 degree opening with two butt hinge.
D. Door Glazing: Float glass, clear, 1/8 inch thick, and set in resilient channel glazing gasket.
E. Cabinet Mounting Hardware: Appropriate to cabinet, with pre-drilled holes for placement of
anchors.
F. Weld, fill, and grind components smooth.
G. Finish of Cabinet Exterior Trim and Door: White.
2.4 ACCESSORIES
A. Extinguisher Brackets: Formed steel, galvanized and enamel finished.
PART 3 EXECUTION
3.1 EXAMINATION
A. Verify existing conditions before starting work.
B. Verify rough openings for cabinet are correctly sized and located.
3.2 INSTALLATION
A. Install in accordance with manufacturer's instructions.
B. Install cabinets plumb and level in wall openings, not more than 48 inches from finished floor to
inside bottom of cabinet.
C. Secure rigidly in place.
D. Place extinguishers in cabinets.
SECTION 101400 - SIGNAGE
PART 1 GENERAL
1.1 SECTION INCLUDES
A. Code required signage.
1.2 REFERENCE STANDARDS
A. 36 CFR 1191 - Americans with Disabilities Act (ADA) Accessibility Guidelines for Buildings and
Facilities; Architectural Barriers Act (ABA) Accessibility Guidelines; current edition.
B. ADA Standards - Americans with Disabilities Act (ADA) Standards for Accessible Design; 2010.
C. ICC A117.1 - Accessible and Usable Buildings and Facilities; 2017.
1.3 SUBMITTALS
A. See Section 013000 - Administrative Requirements, for submittal procedures.
B. Product Data: Manufacturer's printed product literature for each type of sign, indicating sign styles,
font, foreground and background colors, locations, overall dimensions of each sign.
C. Signage Schedule: Provide information sufficient to completely define each sign for fabrication,
including room number, room name, other text to be applied, sign and letter sizes, fonts, and colors.
1. When room numbers to appear on signs differ from those on drawings, include the drawing
room number on schedule.
2. When content of signs is indicated to be determined later, request such information from Owner
through Architect at least 2 months prior to start of fabrication; upon request, submit preliminary
schedule.
3. Submit for approval by Owner through Architect prior to fabrication.
D. Samples: Submit two samples of each type of sign, of size similar to that required for project,
illustrating sign style, font, and method of attachment.
E. Selection Samples: Where colors are not specified, submit two sets of color selection charts or
chips.
F. Verification Samples: Submit samples showing colors specified.
G. Manufacturer's Installation Instructions: Include installation templates and attachment devices.
H. Maintenance Materials: Furnish the following for Owner's use in maintenance of project.
1. See Section 016000 - Product Requirements, for additional provisions.
1.4 QUALITY ASSURANCE
A. Manufacturer Qualifications: Company specializing in manufacturing the products specified in this
section with minimum three years of documented experience.
1.5 DELIVERY, STORAGE, AND HANDLING
A. Package signs as required to prevent damage before installation.
B. Store tape adhesive at normal room temperature.
1.6 FIELD CONDITIONS
A. Do not install tape adhesive when ambient temperature is lower than recommended by
manufacturer.
B. Maintain this minimum temperature during and after installation of signs.
PART 2 PRODUCTS
2.1 MANUFACTURERS
A. Flat Signs:
1. Best Sign Systems HYPERLINK "http://www.bestsigns.com/#sle", Inc: www.bestsigns.com/
#sle.
2. HYPERLINK "http://www.inprocorp.com/#sle"Inpro: www.inprocorp.com/#sle.
3. Mohawk Sign Systems HYPERLINK "http://www.mohawksign.com/#sle", Inc:
www.mohawksign.com/#sle.
4. Seton Identification Produc HYPERLINK "http://www.seton.com/aec/#sle"ts:
www.seton.com/aec/#sle.
5. Substitutions: See Section 016000 - Product Requirements.
2.2 SIGNAGE APPLICATIONS
A. Accessibility Compliance: Signs are required to comply with ADA Standards and ICC A117.1 and
applicable building codes, unless otherwise indicated; in the event of conflicting requirements,
comply with the most comprehensive and specific requirements.
B. Provide interior signage only as required to comply with building code.
2.3 SIGN TYPES
A. Flat Signs: Signage media without frame.
1. Edges: Square.
2. Corners: Radiused.
3. Wall Mounting of One-Sided Signs: Tape adhesive.
B. Color and Font: Unless otherwise indicated:
1. Character Font: As approved by Architect.
2. Character Case: Upper case only.
3. Background Color: As scheduled.
4. Character Color: Contrasting color.
2.4 ACCESSORIES
A. Concealed Screws: Stainless steel, galvanized steel, chrome plated, or other non-corroding metal.
B. Tape Adhesive: Double sided tape, permanent adhesive.
PART 3 EXECUTION
3.1 EXAMINATION
A. Verify that substrate surfaces are ready to receive work.
3.2 INSTALLATION
A. Install in accordance with manufacturer's instructions.
B. Install neatly, with horizontal edges level.
C. Locate signs and mount at heights indicated on drawings and in accordance with ADA Standards
and HYPERLINK "https://global.ihs.com/doc_detail.cfm?&rid=BSD&item_s_key=00006864
&item_key_date=901231&input_doc_number=ICC&input_doc_title" ICC A117.1.
D. HYPERLINK "https://global.ihs.com/doc_detail.cfm?&rid=BSD&item_s_key=00006864
&item_key_date=901231&input_doc_number=ICC&input_doc_title"Protect from damage until
Substantial Completion; repair or replace damaged items.
SHEET NUMBER
4040 N CENTRAL EXPY,
SUITE 720
DALLAS, TEXAS 75204
t 314.302.6864
www.modusarchitecture.com
FOR INFORMATION
PURPOSES ONLY. NOT TO
BE USED IN ANY CAPACITY
FOR BIDDING, PERMITTING,
OR CONSTRUCTION
REVISIONS:
SHEET NAME
ISSUE DATE:
16
2
5
L
A
N
C
A
S
T
E
R
D
R
I
V
E
GR
A
P
E
V
I
N
E
,
T
E
X
A
S
7
6
0
5
1
G135
SPECIFICATIONS
PE
R
M
I
T
S
E
T
CO
O
K
C
H
I
L
D
R
E
N
'
S
12/19/2024
1. CONTRACTOR TO VISIT PROJECT SITE AND BUILDING,
PRIOR TO BID.
2. CONTRACTOR SHALL VERIFY THAT DESIGN INTENT
CAN BE EXECUTED AFTER THOROUGH REVIEW OF
EXISTING CONDITIONS, INCLUDING ALL STRUCTURAL
CONDITIONS.
3. BUILDING AND SITE TO REMAIN SECURE DURING
DEMOLITION AND CONSTRUCTION.
4. PROTECT ALL ITEMS TO REMAIN (WALLS, PLUMBING
FIXTURES, PIPING, HVAC UNITS, COLUMNS, ETC).
5. CONTRACTOR TO PROTECT EXISTING FINISHES
ADJACENT TO DEMOLITION WORK.
6. CONTRACTOR TO PATCH AND REPAIR ALL WORK,
ESPECIALLY WORK ADJACENT TO EXISTING AREAS,
AS REQUIRED.
7. CONTRACTOR TO REPAIR ANY AREAS DAMAGED
DURING DEMOLITION.
8. CONTRACTOR TO COORDINATE DEMOLITION
OPENINGS WITH NEW PLANS AND ELEVATIONS.
9. REMOVE EXISTING GYP BOARD OR PLASTER AS
NECESSARY TO PROVIDE NEW BLOCKING IN
EXISTING WALLS FOR NEW CASEWORK AND
EQUIPMENT.
10. REMOVE EXISTING FINISHES AS REQUIRED TO
ACCOMADATE INSTALLATION OF NEW FINISH ITEMS.
11. PATCH AND REPAIR EXIST. WALLS AS REQ TO MATCH
ADJACENT FINISH.
GENERAL NOTES
DEMOLITION PLANS
EXISTING DOOR AND FRAME TO REMAIN1
NOTES BY NUMBER
DEMOLITION PLANS
DEMO EXISTING EXTERIOR WINDOW, FRAME, AND
WALL AS REQ. PREP FOR NEW DOOR. PRICE
SEPARATELY PER ALTERNATE 01.
2
PRESERVE AND PROTECT EXISTING ROOF HATCH
LOCATION.
3
67
'
-
9
1
/
2
"
N.I.C.
N.I.C.
2'
-
0
"
17
'
-
1
1
1
/
2
"
EXTENT OF NEW CONSTRUCTION
EXTENT OF WALL, MILLWORK,
CEILING AND DOOR DEMO
EXTENT OF NEW CONSTRUCTION
EXTENT OF WALL, MILLWORK
CEILING, AND DOOR DEMO
2'
-
0
"
13
'
-
7
1
/
4
"
2' - 0"
V.I.F.
16' - 11"
1
1
V.I.F.
18' - 11"
2
2
3
REFER TO SHEET G-200 FOR GENERAL DEMOLITION NOTES.
REMOVE ALL
1. FLOOR FINISHES
2. WALL FINISHES INCLUDING WALL BASE & HVAC GRILLES
(PLASTER OR GYPSUM BOARD TO REMAIN WHERE FEASIBLE),
3. WALL PROTECTION
4. FURNISHINGS,
5. MILLWORK,
6. EQUIPMENT,
7. PLUMBING FIXTURES & ACCESSORIES RELATED TO EXISTING
TENANT FINISH OUT. DO NOT REMOVE CORE BUILDING
ELEMENTS. NOTIFY ARCHITECT IN WRITING OF ANY ITEMS OR
COMPONENTS IN QUESTION PRIOR TO DEMOLITION. CAP AND
ABANDON PLUMBING LINES ONLY AS ALLOWED BY BUILDING
MANAGEMENT
8. CEILINGS, INCLUDING BUT NOT LIMITED TO CEILING
SUPPORTS, LIGHTING, & GRILLES
REFER TO SPECIFIC KEY NOTES ON PLANS FOR EXCEPTIONS.
NOT IN CONTRACT
A
C
EXISTING ELEMENT TO REMAIN
(SHOWN GRAYSCALE)
EXISTING ELEMENTS TO BE REMOVED
(SHOWN DASHED BLACK)
REMOVE DOOR AND DOOR FRAME.
DEMOLITION LEGEND
SHEET NUMBER
4040 N CENTRAL EXPY,
SUITE 720
DALLAS, TEXAS 75204
t 314.302.6864
www.modusarchitecture.com
FOR INFORMATION
PURPOSES ONLY. NOT TO
BE USED IN ANY CAPACITY
FOR BIDDING, PERMITTING,
OR CONSTRUCTION
REVISIONS:
SHEET NAME
ISSUE DATE:
16
2
5
L
A
N
C
A
S
T
E
R
D
R
I
V
E
GR
A
P
E
V
I
N
E
,
T
E
X
A
S
7
6
0
5
1
AD111
DEMO FLOOR PLAN
PE
R
M
I
T
S
E
T
CO
O
K
C
H
I
L
D
R
E
N
'
S
12/19/2024
PLAN
NORTH
TRUE
NORTH
1/4" = 1'-0"1 DEMO FLOOR PLAN - LEVEL 01
1
1/
A
7
1
1
2/
A
7
1
1
3/A711
4/A711
6/A711
14/A711
13
/
A
7
1
1
1/
A
7
1
2
4/
A
7
1
2
6/
A
7
1
2
2/A712
5/A712
8/
A
7
1
2
15/A711
3/A712
11/A712
N.I.C.
N.I.C.
3/A712
119
EXAM 12
120
STORAGE
121
EXAM 13
122
EXAM 14
118
EXAM 11
117
EXAM 10
116
EXAM 09
115
EXAM 08
114
IT/ELEC
113
EXAM 07
110
EXAM 06
106
EXAM 03
105
EXAM 02
104
EXAM 01
111
STAFF TLT
112
BREAKROOM
127
MA
STATION
109
EXAM 05
108
EXAM 04
123
EXAM 15
124
NURSING
100
WAITING
128
LAB
125
RECEPTION
107
SHARED
OFFICE
130
STORAGE
103
VITALS
132
TLT
129
TLT
12
'
-
8
7
/
8
"
11
'
-
6
"
11
'
-
6
"
10
'
-
5
1
/
8
"
CL
E
A
R
5'
-
0
"
10
'
-
5
5
/
8
"
6'
-
1
0
5
/
8
"
CL
E
A
R
5'
-
0
"
8'
-
8
"
5'
-
8
7
/
8
"
5'
-
8
7
/
8
"
5'
-
8
7
/
8
"
8'
-
3
1
/
8
"
CLEAR
5' - 0"
CL
E
A
R
5'
-
0
"
CLEAR
5' - 0"
9' - 8 7/8"9' - 10"7' - 6"9' - 10"9' - 10"9' - 10"9' - 10"9' - 10"15' - 11 5/8"
18
'
-
0
3
/
8
"
13
'
-
3
3
/
4
"
35
'
-
1
0
1
/
8
"
2'
-
0
"
1'
-
0
"
8'
-
1
1
"
2'
-
9
1
/
2
"
7
1
/
4
"
6'
-
4
3
/
4
"
11
'
-
7
5
/
8
"
7' - 11 7/8"7' - 0"6' - 6 1/8"17' - 0 3/4"
7'
-
0
"
12
'
-
3
5
/
8
"
4'
-
1
0
"
22' - 3 7/8"3' - 2 1/4"
1' - 11 1/2"1' - 0 1/2"
4' - 6"6' - 10 5/8"
CLEAR
4' - 2"2' - 8 7/8"2' - 7"
CLEAR
4' - 0"10' - 7 3/8"
3'
-
0
5
/
8
"
7'
-
1
0
7
/
8
"
4'
-
1
0
1
/
8
"
5'
-
2
7
/
8
"
8'
-
6
1
/
4
"
4'
-
7
"
10' - 2 5/8"
1' - 7 1/4"
7' - 10 7/8"21' - 8 1/8"
2' - 4"
24' - 1 7/8"8' - 2 7/8"7' - 0 7/8"9' - 6"9' - 11 3/8"
CLEAR
5' - 3 1/2"10' - 3 1/2"5' - 11 1/8"10' - 2 5/8"
1
12
2
12
1
12
0
11
9
11
7
11
6
11
5
11
4
113
11
1
110
132
130
109
108
129
10
7
10
6
10
5
10
4
100B
10
0
A
124
12
3
12
6
125
F2C
F2C
F3C
F3C
F3C F3C
F3
C
F3
C
F3
C
F3
C
A121
1
A121
1
SIM
7'
-
6
"
7' - 2 5/8"
7'
-
6
"
7' - 2 5/8"
126
OFFICE
7/A711
5/A711
12/A711
10
/
A
7
1
2
9/A712
8/A711
10/A711
9/A711
16
/
A
7
1
1
A121
1
SIM
A121
1
SIM
EQ
EQ
102
TLT
131
EVS
102
101
RISER
ROOM
131
11
8
A6A
7'
-
7
1
/
8
"
A6
A
A6A
2
2 2
2
2
2
17
'
-
4
1
/
4
"
A6A
15
'
-
3
"
11
'
-
4
7
/
8
"
5'
-
5
7
/
8
"
CL
E
A
R
5'
-
0
"
11
'
-
7
5
/
8
"
9' - 3 7/8"7' - 0"6' - 4 7/8"3' - 10 1/4"4' - 10 7/8"1' - 11 1/8"6' - 5 3/4"
CL
E
A
R
4'
-
0
"
5'
-
0
"
CL
E
A
R
2'
-
8
"
3'
-
2
1
/
8
"
O.H.
10' - 8 3/4"
A121
6
A121
8
A121
7
F2
C
F2C
F2
C
A121
9
35.00°
2' - 2 3/4"
7' - 10"
3
3
CL
E
A
R
5'
-
0
"
1
44
4
4
4
4
A3
C
F3
C
2
7/
A
7
1
2
7/
A
7
1
2
5
17
/
A
7
1
1
15
'
-
4
3
/
8
"
4'
-
1
0
7
/
8
"
11
/
A
7
1
1
A121
10
A121
10
SIM
A121
10
SIM
A121
10
SIM
A6
C
F3C
F3C
F3C
112
5
1' - 11 3/8"5' - 4 7/8"
1'
-
1
1
3
/
8
"
12
'
-
7
5
/
8
"
CLEAR
4' - 0"
CLEAR
4' - 0"
1'
-
1
1
3
/
8
"
12
'
-
7
5
/
8
"
5' - 6 1/8"
1
1
/
4
"
7
6
CL
E
A
R
3'
-
0
3
/
4
"
13
3
10
1
7'
-
6
"
4'
-
1
1
"
CL
E
A
R
5'
-
0
"
4'
-
1
1
"
CL
E
A
R
5'
-
0
"
CL
E
A
R
5'
-
2
"
CL
E
A
R
5'
-
0
"
CLEAR
4' - 0"
TY
P
.
CLEAR
1' - 6" MIN
CL
E
A
R
1'
-
6
"
M
I
N
.
EQ EQ
2'
-
0
7
/
8
"
2'
-
4
3
/
8
"
CLEAR
6' - 0"
CLEAR
4' - 0"
ALIGN FINISH FACE TO ADJACENT WALLS1
PROVIDE OPACITY FILM ON INTERIOR SIDE OF
EXISTING STOREFRONT GLASS
BOD: FASARA GLASS FINISHES; OPAQUE MATTE
WINDOW FINISH
MANUF: 3M
COLOR: WHITE SH2MA0W
2
PROVIDE TRANSLUCENT FILM ON INTERIOR SIDE
OF EXISTING STOREFRONT GLASS.
BOD: FASARA GLASS FINISHES; SEMI-
TRANSPARENT FROSTED WINDOW FILM
MANUF: 3M
COLOR: DUSTED CRYSTAL; 7725SE-314
3
PROVIDE COLUMN WRAP AT EXISTING COLUMNS.
KEEP STUDS TIGHT TO FACE OF COLUMN
4
PROVIDE MS2 ROLLER SHADE ON INTERIOR
SIDE OF EXISTING STOREFRONT GLASS.
RE: FINISH LEGEND
5
NOTES BY NUMBER
FLOOR PLAN
LINE OF SOFFIT ABOVE.6
1. PARTITION TYPES APPLY TO INTERIOR PARTITIONS
ONLY.
2. REFERENCE REFLECTING CEILING PLANS AND
LIFESAFETY PLANS TO DETERMINE FIRE RATING
REQUIREMENTS. FIRE RATED NOTATION SUPERSEDE
HEAD CONDITION INDICATION.
3. SLIP TRACK HEAD CONDITIONS ARE REQUIRED AT ALL
PARITIONS TO DECK OR STRUCTURE. REFERENCE
STRUCTURAL FOR DEFLECTION CRITERIA.
4. GENERAL CONTRACTOR IS RESPONSIBLE FOR
CONSTRUCTING THE COMPLETE ASSEMBLY OF ALL
FIRE RATED PARTITIONS IN FULL ACCORDANCE WITH
UL LISTING.
5. ALL INTERIOR PARTIIONS STUDS TO BE 25 GAUGE
MINIMUM, SHAFT WALL STUDS TO 20 GAUGE MINIMUM.
REFER STUD SPAN FOR SPACNIG AND BRACING.
REFERENCE SPECIFICATIONS FOR FRAMED OPENING
CONDITIONS
6. REFERENCE CHART BELOW FOR MINIMUM REQUIRE
PARTITION BRACING REQUIREMENT.
7. STC RATINGS REFLECT LAB TEST INFORMATION.
8. WHEN SOUND ATTENUATION BATTS AND AN
ACOUSTICAL SEALANT AT TOP AND BOTTOM OF
PARTITION ARE INSTALLED.
9. PARTITIONS SHALL BE COORDINATED WITH
SCHEDULED FINISHES FOR PARTITION LAYOUT AND
REQUIRED CLEARANCES.
10. PROVIDE BLOCKING IN PARTITIONS FOR WALL
SUPPORTED ELEMENTS INCLUDING BUT NOT LIMITED
TO ARCHITECTURAL WOODWORK, ACCESSORIES,
FURNITURE, ART, AV VENDORS.
11. FOR INTERIOR FRAMING LIMITING HEIGHTS REFER TO
SSMA TABLES FOR INTERIOR NON-STRUCTURAL NON-
COMPOSITE PARTITIONS.
12. CONTRACTOR TO CONFIRM STUD SIZING AND
SPACING PER CRITERIA IN SPECIFICATIONS.
A = UNBRACED PARTITION TO UNDERSIDE OF DECK WALLS
WILL TERMINATE TO BOTTOM OF STRUCTURAL DECK
B = PARTITION TO UNDERSIDE OF DECK
WALLS WILL TERMINATE TO BOTTOM OF STRUCTURAL
DECK
C = PARTITION TO ABOVE CEILING
WALLS WILL TERMINATE AT A MINIMUM OF 6" ABOVE
HIGHEST ADJOINING CEILING UNLESS NOTES
OTHERWISE ON PLAN. TERMINATE 1 FULL COURSE
ABOVE AT MASONRY WALLS
D = PARTITION TO BOTTOM OF CEILING
WALL EXTENDS TO UNDERSIDE OF CEILING.
E = PARTIAL HEIGHT PARITION
RE: ELEVATIONS FOR HEIGHT.
PARTITION TYPES
TABLE A- PARTITION TYPE CONSTRUCTION ASSEMBLY
TABLE B- FRAMING DEPTH SCHEDULE
TAG NUMBER
DESIGNATION
MTL STUD
DEPTH
MTL C-H STUD
DEPTH
WOOD STUD
DEPTH
GENERAL NOTES
GN-01.PARTITIONS SHALL BE COORDINATED WITH
SCHEDULED FINISHES FOR PARTITION LAYOUT AND
REQUIRED CLEARANCES.
GN-02.PROVIDE BLOCKING IN PARTITIONS FOR WALL
SUPPORTED ELEMENTS INCLUDING BUT NOT LIMITED
TO ARCHITECTURAL WOODWORK, ACCESSORIES,
FURNITURE, ART, AV VENDORS.
GN-03.FOR INTERIOR FRAMING LIMITING HEIGHTS
REFER TO SSMA TABLES FOR INTERIOR NON-
STRUCTURAL NON-COMPOSITE PARTITIONS
GN-04. CONTRACTOR TO CONFIRM STUD SIZING AND
SPACING PER CRITERIA IN SPECIFICATIONS.
GN-06. REQUIRED MINIMUM STC RATING NOTED IN
PARTITION SCHEDULES:
SERIES SHEATHING FRAMING MEMBERS SHEATHING
1 LAYER METAL C STUD 1 LAYERA
1 LAYER METAL C STUD 1 LAYERB
1 LAYER METAL C STUD 2 LAYERSC
1 LAYER METAL C STUD NONED
2 LAYERS METAL C STUD NONEE
1 LAYER METAL HAT CHANNELNONEF
1 LAYER NONE NONEG
1 LAYER METAL C-H STUD NONEH
2 LAYERS METAL C-H STUD LINER PNLJ
1 LAYER (2) METAL C STUDS 1 LAYERK
2 LAYERS (2) METAL C STUDS 2 LAYERSL
NONE CMU NONEM
RESERVED FOR FUTURE EXPANSIONN-U
CUSTOM N/A N/AV-Z
GN-05. PROVIDE 16 AND 18 GAUGE METAL FOR
STRUCTURAL FRAMING; AND 20, 22, AND 25 GAUGE
FOR NON-STRUCTURAL FRAMING. ADJUST GAUGE
ACCORDINGLY FOR VERTICALLY SPANNING WALLS.
-
7/8" FURRING CHANNEL N/A0
1 5/8" N/A N/A1
NO FRAMING
2 1/2"N/A" N/A2
3 5/8" N/A N/A3
4" N/A N/A4
6" N/A N/A6
8" N/A N/A8
10" N/A N/A10
## / ##
WITH SOUND ATTENUATION
WITHOUT SOUND ATTENUATION
A B C D E
PARTITION TO
EXTEND TO
UNDERSIDE OF DECK
PARTIAL HEIGHT
PARTITION REF.
ELEVATION FOR
HEIGHT
3-5/8" MTL. STUD
BRACING AT 45' (TYP)
STAGGERED AT
4'-0" EACH SID
SECURED TO
STRUCTURE
PARTITION TO
EXTEND ABOVE
CEILING
EXISTING
PARTITION TO
EXTEND
ABOVE
CEILING
CEILING HEIGHT
SHOULD NOT
EXCEED MAX.
UNBRACED STUD
HEIGHT
SUSPENDED
CEILING AS
SCHEDULED
EXISTING PARTITION
TO
EXTEND TO
UNDERSIDE OF
DECK
PARTITION TAG
PARTITION HEAD CONDITION
(SEE GRAPH 1 - BELOW)
FRAMING MEMBER DEPTH
(SEE TABLE B - BELOW)
PARTITION SERIES
(SEE TABLE A - BELOW)
A4A
SOUND ATTENUATION - WALL INSTANCE
(SEE CONSTRUCTION PLAN)
PARTITION TYPE LEGEND
1 LAYER OF 5/8" GYPSUM
BOARD
METAL STUD - REFER SCHEDULE
BASIC PARTITION THICKNESS
LINE OF STRUCTURE
ACOUSTICAL OR FIRESTOPPING
SEALANT WHERE INDICATED
SOUND ATTENUATION BATTS
WHERE INDICATED
LINE OF STRUCTURE
ACOUSTICAL OR FIRESTOPPING
SEALANT WHERE INDICATED
METAL STUD TRACK
LINE OF CEILING
METAL STUD TRACK
METAL STUD - REFER SCHEDULE
LINE OF STRUCTURE
ACOUSTICAL OR FIRESTOPPING
SEALANT WHERE INDICATED
SOUND ATTENUATION BATTS
WHERE INDICATED
LINE OF STRUCTURE
ACOUSTICAL OR FIRESTOPPING
SEALANT WHERE INDICATED
METAL STUD TRACK
LINE OF CEILING
METAL STUD TRACK
1 LAYER OF 5/8" GYPSUM BOARD
1. RE: SHEET G001 FOR ADDITIONAL GENERAL NOTES
THAT ARE APPLICABLE.
2. REFERENCE SHEET G003-G004 FOR FIXTURE &
ACCESSORY MOUNTING HEIGHTS & LOCATION.
3. DIMENSIONS SHOWN ON THE FLOOR PLAN ARE TO THE
FACE OF GYP. BOARD/ WALL (FOG), FACE OF MASONRY
(FOM), FACE OF CONCRETE WALLS (FOC), AND COLUMN
GRID LINES, UNLESS NOTED OR SHOWN OTHERWISE.
4. DOOR OPENINGS NOT LOCATED BY DIMENSION SHALL
BE CENTERED IN WALL SHOWN OR LOCATED 4" FROM
FINISH WALL TO HINGE SIDE OF THE DOOR, ALWAYS
ALLOWING A MINIMUM OF 18" FROM THE PULL SIDE
(STRIKE SIDE) OF THE DOOR TO THE INTERSECTING
WALL, OR OTHER PROTRUDING OBJECTS.
5. ALL CLOSETS AND ALCOVES WITHOUT A SPACE
IDENTIFICATION NUMBER SHALL HAVE THE SAME
FINISHES AS THE ADJOINING SPACES.
6. ALL PUBLIC SPACES: WALLS WILL BE FINISHED WITH
5/8" GYP. BD. TO A LEVEL 4H ROLLER FINISH AND
PAINTED, UNLESS NOTED OR SPECIFIED OTHERWISE.
7. RE: DOOR SCHEDULE, FINISH SCHEDULE AND
SPECIFICATIONS FOR DOOR AND DOOR FRAME
FINISHES.
8. PROVIDE MINIMUM 1'-0" CLEAR FLOOR SPACE AT THE
PUSH SIDE OF EVERY DOOR WITH A CLOSER. PROVIDE
MINIMUM 1'-6" CLEAR AT THE PULL SIDE OF EVERY
DOOR, UNLESS SPECIFICALLY DIMENSIONED, NOTED
OR SHOWN OTHERWISE.
9. ALL WALL PARTITIONS ARE TYPE A3C INSULATED U.N.O.
10. OFOI FURNITURE SYSTEMS DASHED IN FOR CLARITY.
11. EXISTING WALLS TO REMAIN: PATCH AND REPAIR AS
REQ. TO PROVIDE LEVEL 4 FINISH. RE: FINISH PLAN FOR
WALL FINISH
GENERAL NOTES
FLOOR PLAN
SHEET NUMBER
4040 N CENTRAL EXPY,
SUITE 720
DALLAS, TEXAS 75204
t 314.302.6864
www.modusarchitecture.com
FOR INFORMATION
PURPOSES ONLY. NOT TO
BE USED IN ANY CAPACITY
FOR BIDDING, PERMITTING,
OR CONSTRUCTION
REVISIONS:
SHEET NAME
ISSUE DATE:
16
2
5
L
A
N
C
A
S
T
E
R
D
R
I
V
E
GR
A
P
E
V
I
N
E
,
T
E
X
A
S
7
6
0
5
1
A111
OVERALL FLOOR
PLAN
PE
R
M
I
T
S
E
T
CO
O
K
C
H
I
L
D
R
E
N
'
S
12/19/2024
PLAN
NORTH
TRUE
NORTH
1/4" = 1'-0"1 FLOOR PLAN
1 1/2" = 1'-0"2 A TYPE PARTITION
1 1/2" = 1'-0"3 F TYPE PARTITION
PARTITION
TYPE MARK
STUD
DEPTH
FIRE
RATING
TESTED
ASSEMBLY STC RTG SHEET NOTES
A3C 3 5/8" UL U419 48
A6A 5 1/2" 1 UL U419 48
A6C 5 1/2" UL U419 48
PARTITION
TYPE MARK
STUD
DEPTH
FIRE
RATING
TESTED
ASSEMBLY STC RTG SHEET NOTES
F2C 2 1/2"
F3C 3 5/8"
J
+36"
J
+3
6
"
US
B
+1
8
"
US
B
+1
8
"
USB
+18"
USB
+18"
+1
8
"
+
1
8
"
+
1
8
"
+18" +18"
+1
8
"
+
1
8
"
USB
+38"
+1
8
"
+18"
+1
8
"
+
1
8
"
+
1
8
"
+
1
8
"
+18"
+1
8
"
+
1
8
"
+
1
8
"
+
1
8
"
+
1
8
"
+
1
8
"
+
1
8
"
+
1
8
"
+4
4
"
+
4
4
"
+
4
4
"
+4
4
"
+
4
4
"
+4
4
"
+4
4
"
+
4
4
"
+1
8
"
+
1
8
"
+1
8
"
+4
4
"
+44"
+4
2
"
+
4
2
"
+
1
8
"
+42" +18" +42" +42"
+18" +18" +18"
+1
8
"
+
1
8
"
+18"+18"
+1
8
"
+
1
8
"
+18" +18"
+1
8
"
US
B
+1
8
"
USB
+42"
+18"
+18"
+18"
+18"
+18"
+1
8
"
+
1
8
"
+42"
+1
8
"
+
1
8
"
+18"
+18"
USB
+18"
US
B
+1
8
"
+18"
+1
8
"
+1
8
"
+18"
+18" +18"
+4
2
"
+1
8
"
+
1
8
"
+18"
+18"
+18"
+1
8
"
+18"
+18"
+18"
+42"
+18"
+18"
+1
8
"
USB
+18"
USB
+18"
US
B
+1
8
"
US
B
+1
8
"
+18"
+18"
+18"
+1
8
"
+1
8
"
+
1
8
"
+1
8
"
+4
4
"
+42"
+1
8
"
+1
8
"
+
1
8
"
+
1
8
"
+38"
+18"
+1
8
"
+1
8
"
USB
+18"
+18"
+1
8
"
+1
8
"
+18"
+1
8
"
+18"
+18"
+1
8
"
+1
8
"
+1
8
"
+18"
+18"
+18"
+1
8
"
+1
8
"
N.I.C.
N.I.C.
119
EXAM 12
RE: TYP. EXAM
120
STORAGE
121
EXAM 13
RE: TYP. EXAM
122
EXAM 14
RE: TYP. EXAM
118
EXAM 11
RE: TYP. EXAM
117
EXAM 10
RE: TYP. EXAM
116
EXAM 09
RE: TYP. EXAM
115
EXAM 08
114
IT/ELEC
113
EXAM 07
RE: TYP. EXAM
110
EXAM 06
106
EXAM 03
RE: TYP. EXAM
105
EXAM 02
RE: TYP. EXAM
104
EXAM 01
111
STAFF TLT
112
BREAKROOM
127
MA
STATION
109
EXAM 05
108
EXAM 04
123
EXAM 15 124
NURSING
100
WAITING
128
LAB
125
RECEPTION
107
SHARED
OFFICE
103
VITALS
132
TLT
129
TLT
126
OFFICE
1' - 6"
1' - 8"
9"
130
STORAGE
102
TLT
131
EVS
101
RISER
ROOM
2' - 0"
3'
-
4
"
3' - 0"
TYP. EXAM ROOM
3'
-
6
"
3' - 4"
3' - 4"
3'
-
6
"
2'
-
0
"
3' - 4"
3'
-
6
"
2'
-
0
"
1'
-
8
"
4'
-
2
"
3'
-
8
"
2'
-
1
0
"
EQ
EQ
EQ EQ EQ
1' - 8"
1'
-
6
"
2'
-
8
"
EQ
EQ
EQ
10
"
4'
-
8
"
5' - 0"
4'
-
0
"
2' - 8"3' - 2"6' - 0"2' - 2"2' - 2"1' - 8"
3' - 0"
2' - 0"
3'
-
4
"
1
EQ EQ
1' - 6"
3' - 0"
3'
-
4
"
1' - 2"1' - 4"
2'
-
5
"
1'
-
4
"
8'
-
1
"
1'
-
4
"
2'
-
0
"
1'
-
8
"
1'
-
4
"
1'
-
4
"
1'
-
4
"
4'
-
1
0
"
6"
3' - 6"8"
6"8"
8'
-
4
"
3'
-
2
"
3' - 2"
2'
-
4
"
1'
-
6
"
2'
-
7
1
/
2
"
2'
-
7
1
/
2
"
2'
-
7
1
/
2
"
EQ
EQ
2' - 7 1/2"
1' - 10"
5'
-
0
"
4'
-
4
"
2'
-
8
"
3'
-
7
"
4'
-
1
0
"
5'
-
1
0
"
6'
-
1
"
3'
-
1
0
"
2' - 2"
3'
-
6
"
EQ
EQ
3'
-
1
0
"
1' - 0"4' - 0"4' - 0"
2' - 0"4' - 10"2' - 4"
5'
-
8
"
2'
-
4
"
4' - 2"
2'
-
6
"
2'
-
6
"
1' - 0"
5'
-
0
"
5' - 0"
5' - 0"
5' - 0"
5'
-
0
"
3'
-
0
"
2
1. RE: SHEET G001 FOR ADDITIONAL GENERAL NOTES
THAT ARE APPLICABLE.
2. REFERENCE SHEET G003-G004 FOR FIXTURE &
ACCESSORY MOUNTING HEIGHTS & LOCATION.
3. DIMENSIONS SHOWN ON THE FLOOR PLAN ARE TO THE
FACE OF GYP. BOARD/ WALL (FOG), FACE OF MASONRY
(FOM), FACE OF CONCRETE WALLS (FOC), AND COLUMN
GRID LINES, UNLESS NOTED OR SHOWN OTHERWISE.
4. DOOR OPENINGS NOT LOCATED BY DIMENSION SHALL
BE CENTERED IN WALL SHOWN OR LOCATED 4" FROM
FINISH WALL TO HINGE SIDE OF THE DOOR, ALWAYS
ALLOWING A MINIMUM OF 18" FROM THE PULL SIDE
(STRIKE SIDE) OF THE DOOR TO THE INTERSECTING
WALL, OR OTHER PROTRUDING OBJECTS.
5. ALL CLOSETS AND ALCOVES WITHOUT A SPACE
IDENTIFICATION NUMBER SHALL HAVE THE SAME
FINISHES AS THE ADJOINING SPACES.
6. ALL PUBLIC SPACES: WALLS WILL BE FINISHED WITH
5/8" GYP. BD. TO A LEVEL 4H ROLLER FINISH AND
PAINTED, UNLESS NOTED OR SPECIFIED OTHERWISE.
7. RE: DOOR SCHEDULE, FINISH SCHEDULE AND
SPECIFICATIONS FOR DOOR AND DOOR FRAME
FINISHES.
8. PROVIDE MINIMUM 1'-0" CLEAR FLOOR SPACE AT THE
PUSH SIDE OF EVERY DOOR WITH A CLOSER. PROVIDE
MINIMUM 1'-6" CLEAR AT THE PULL SIDE OF EVERY
DOOR, UNLESS SPECIFICALLY DIMENSIONED, NOTED
OR SHOWN OTHERWISE.
9. ALL WALL PARTITIONS ARE TYPE A3C INSULATED U.N.O.
10. OFOI FURNITURE SYSTEMS DASHED IN FOR CLARITY.
11. EXISTING WALLS TO REMAIN: PATCH AND REPAIR AS
REQ. TO PROVIDE LEVEL 4 FINISH. RE: FINISH PLAN FOR
WALL FINISH
GENERAL NOTES
FLOOR PLAN
CONTROLS AND TSTAT LOCATION, RE: MECH1
NOTES BY NUMBER
POWER PLAN
PROVIDE POWER ON BACK UP BATTERY FOR LAB
REFRIGERATORS, RE: ELEC
2
SHEET NUMBER
4040 N CENTRAL EXPY,
SUITE 720
DALLAS, TEXAS 75204
t 314.302.6864
www.modusarchitecture.com
FOR INFORMATION
PURPOSES ONLY. NOT TO
BE USED IN ANY CAPACITY
FOR BIDDING, PERMITTING,
OR CONSTRUCTION
REVISIONS:
SHEET NAME
ISSUE DATE:
16
2
5
L
A
N
C
A
S
T
E
R
D
R
I
V
E
GR
A
P
E
V
I
N
E
,
T
E
X
A
S
7
6
0
5
1
A112
OVERALL POWER
PLAN
PE
R
M
I
T
S
E
T
CO
O
K
C
H
I
L
D
R
E
N
'
S
12/19/2024
PLAN
NORTH
TRUE
NORTH
1/4" = 1'-0"1 FLOOR PLAN - POWER
N.I.C.
N.I.C.
119
EXAM 12
120
STORAGE
121
EXAM 13
122
EXAM 14
118
EXAM 11
117
EXAM 10
116
EXAM 09
115
EXAM 08 114
IT/ELEC
113
EXAM 07
110
EXAM 06
106
EXAM 03
105
EXAM 02
104
EXAM 01
111
STAFF TLT
112
BREAKROOM
127
MA
STATION
109
EXAM 05
108
EXAM 04
123
EXAM 15
124
NURSING
100
WAITING
128
LAB
125
RECEPTION
107
SHARED
OFFICE
130
STORAGE
103
VITALS
132
TLT
129
TLT
A121
1
SIM
126
OFFICE
A121
1
SIM
A121
1
SIM
102
TLT
131
EVS
101
RISER
ROOM
O.H.
MFZ1
MRF1
CM1
MCW1
REF1
TV2
TV1
PC1
PC1
PT1
MS1
PT2
PT2
PT2
CH1
TYP. ALL EXAM ROOMS
PT2
AED
TYP. ALL EXAM ROOMS
ST1
LB1
B02
B03
B03
B02
A121
1
SIM
B04
B06
B02
B07
PRT2
SC1
PRT1
PRT2
PRT2
DH1
HS1
TYP. ALL EXAM ROOMS
SH1
GD1
UCF1
SD1
SD1
SD1
SD1
LRF1
VC1
VC1
PRT2
PRT2
PRT2
BELOW
BELOW
TEL1
PRT3
PRT3
PRT3
SC1 ST1
SC2
OTS1
ALZ1
EC2
EC1
EC2
EC1
DT1
WS1
EW1
CH1
HS1
DT1
SD1
PT2
LOCATE ON DOOR
MR2
1
3'
-
8
"
3'
-
8
"
FURNITURE ITEM, OFOI1
NOTES BY NUMBER
EQUIPMENT PLAN
1. RE: SHEET G001 FOR ADDITIONAL GENERAL NOTES
THAT ARE APPLICABLE.
2. REFERENCE SHEET G003-G004 FOR FIXTURE &
ACCESSORY MOUNTING HEIGHTS & LOCATION.
COORDINATE ALL DOORS TO BE CLEAR OF
ACCESSORIES AND EQUIPMENT PER ACCESSIBILITY
REQUIREMENTS.
3. DIMENSIONS SHOWN ON THE FLOOR PLAN ARE TO THE
FACE OF GYP. BOARD/ WALL (FOG), FACE OF MASONRY
(FOM), FACE OF CONCRETE WALLS (FOC), AND COLUMN
GRID LINES, UNLESS NOTED OR SHOWN OTHERWISE.
4. OFOI FURNITURE SYSTEMS DASHED IN FOR CLARITY.
5. PROVIDE WALL BLOCKING AS REQUIRED FOR ALL WALL
MOUNTED EQUIPMENT AND ACCESSORIES. PROVIDE
FIRE RATED BLOCK AT ANY RATED ASSEMBLIES PER
SPECIFICATIONS.
GENERAL NOTES
EQUIPMENT PLAN
SHEET NUMBER
4040 N CENTRAL EXPY,
SUITE 720
DALLAS, TEXAS 75204
t 314.302.6864
www.modusarchitecture.com
FOR INFORMATION
PURPOSES ONLY. NOT TO
BE USED IN ANY CAPACITY
FOR BIDDING, PERMITTING,
OR CONSTRUCTION
REVISIONS:
SHEET NAME
ISSUE DATE:
16
2
5
L
A
N
C
A
S
T
E
R
D
R
I
V
E
GR
A
P
E
V
I
N
E
,
T
E
X
A
S
7
6
0
5
1
A113
OVERALL
EQUIPMENT PLAN
PE
R
M
I
T
S
E
T
CO
O
K
C
H
I
L
D
R
E
N
'
S
12/19/2024
PLAN
NORTH
TRUE
NORTH
1/4" = 1'-0"1 FLOOR PLAN - EQUIPMENT
EQUIPMENT SCHEDULE
TYPE MARK DESCRIPTION MANUFACTURER MODEL PROCUREMENT INSTALL COMMENTS
AED SEMI-RECESSED AED ZOLL 1399837 PDC FACILITIES MGMT
ALZ1 ANALYZER ABBOTT ID NOW PDC FACILITIES MGMT
CH1 CLOTHING HOOK BOBRICK B-6777 CONTRACTOR CONTRACTOR
CM1 COFFEE MAKER TBD TBD PDC FACILITIES MGMT PROVIDE WATER CONNECTION
DH1 DOCUMENT HOLDER @ ALL EXAM ROOM DOORS TBD TBD PDC CONTRACTOR PROVIDE FR BLOCKING IN WALL AS REQ.
DT1 DRIP TRAY HENRY SCHEIN 4370010 CCPN FACILITIES MGMT
EC1 EYE CHART HENRY SCHEIN LETTERS PDC PDC
EC2 EYE CHART HENRY SCHEIN PICTURES PDC PDC
GD1 GLOVE DISPENSER @ ALL EXAM ROOMS MEDLINE MDS194097B PDC CONTRACTOR COORDINATE FINAL LOCATIONS WITH OWNER
HS1 HAND SANIZER DISPENSER @ ALL EXAM ROOMS PURELL ES4 PDC CONTRACTOR PROVIDE FR BLOCKING IN WALL AS REQ.
LB1 LAB BOXES AND STANDS TBD TBD FACILITIES MGMT CONTRACTOR COORDINATE WITH OWNER, PROVIDE FR BLOCKING IN WALLS AS REQ.
LRF1 UNDER COUNTER REFRIGERATOR @ LAB SUMMIT CT661WBISSHVADA CONTRACTOR CONTRACTOR
MCW1 COUNTERTOP MICROWAVE @ BREAKROOM SHARP 1000 R-21LTF CONTRACTOR CONTRACTOR
MFZ1 FREEZER AND REFRIGERATOR STACK FOLLET FZR5P + REF5BBP PDC FACILITIES MGMT PROVIDE DEDICATED AND COVERED POWER. SEPARATE UNITS. STACK PER MANUF. REQ.
MR2 WELDED-FRAME GLASS MIRROR BOBRICK B-290 2464 CONTRACTOR CONTRACTOR
MRF1 REFRIGERATOR @ LAB FOLLET REF25-LB-L0000G PDC FACILITIES MGMT PROVIDE DEDICATED AND COVERED POWER.
MS1 MOP SHELF BOBRICK B-224X36 CONTRACTOR CONTRACTOR
EQUIPMENT SCHEDULE
TYPE MARK DESCRIPTION MANUFACTURER MODEL PROCUREMENT INSTALL COMMENTS
OTS1 OTOSCOPE WELCH ALLYN 25020A PDC FACILITIES MGMT
PRT1 PRINT / SCAN / COPY CANON ADVANCED C4400 IT/IS IT/IS COORDINATE WITH OWNER
PRT2 PRINTER HP E50145 IT/IS IT/IS
PRT3 LABEL PRINTER TBD TBD IT/IS IT/IS
REF1 REFRIGERATOR @ BREAKROOM GE GFE24JYKFS CONTRACTOR CONTRACTOR PROVIDE WATER CONNECTION
SC1 STANDING DIGITAL SCALE HEALTH-O-METER 349KLX PDC PDC COORDINATE WITH OWNER
SC2 PEDIATRIC SCALE HEALTH-O-METER 553KL PDC PDC COORDINATE WITH OWNER
SH1 SHARPS CONTAINER @ ALL EXAM ROOMS CARDINAL HEALTH 85165H PDC CONTRACTOR
ST1 STADIOMETER @ VITALS HEALTH-O-METER 205HR PDC CONTRACTOR COORDINATE WITH OWNER
TEL1 WALL MOUNTED TELEPHONE TBD TBD
TV1 TV MOUNT PEERLESS ST650 (P) IT/IS CONTRACTOR COORDINATE WITH OWNER, PROVIDE FR BLOCKING IN WALLS AS REQ.
TV2 TV @ WAITING SAMSUNG UN55AU8000F IT/IS IT/IS
UCF1 UNDER COUNTER REFRIGERATOR @BREAKROOM SUMMIT ALFZ37BSSTB COORDINATE CLEARANCE REQUIREMENTS WITH MILLWORK PER MANUF.
VC1 VACCINE COMPUTERS @LAB TBD TBD IT/IS IT/IS PROVIDE POWER AND DATA
WS1 WIRE SHELVING NEXEL A24547C5 CONTRACTOR CONTRACTOR
TOILET ACCESSORY SCHEDULE
TYPE MARK DESCRIPTION MFR MODEL
PROCUREMEN
T INSTALL COMMENTS
GB1 GRAB BAR BOBRICK B-6806-42 CONTRACTOR CONTRACTOR PROVIDE FR BLOCKING IN WALL AS REQ.
GB2 GRAB BAR BOBRICK B-6806x36 CONTRACTOR CONTRACTOR PROVIDE FR BLOCKING IN WALL AS REQ.
MR1 WELDED-FRAME GLASS MIRROR BOBRICK B-290 2436 CONTRACTOR CONTRACTOR PROVIDE FR BLOCKING IN WALL AS REQ.
PC1 PASS-THROUGH CABINET AMERICAN SPECIALTIES 8154 CONTRACTOR CONTRACTOR REFERENCE EQUIPMENT PLAN FOR LOCATIONS. COORDINATE MODEL WITH WALL THICKNESS
PT1 PAPER TOWEL DISPENSER GEORGIA PACIFIC ENMOTION 59466 PDC CONTRACTOR PROVIDE FR BLOCKING IN WALL AS REQ., PROVIDE POWER FOR AUTO SENSOR, RE: ELEC
PT2 PAPER TOWEL DISPENSER (STAFF) BOBRICK B-26212 PDC CONTRACTOR <varies>
SD1 SOAP DISPENSER PROVON ADX-12, 8871-06 PDC CONTRACTOR PROVIDE FR BLOCKING IN WALL AS REQ.
TT1 TOILET TISSUE DISPENSER BOBRICK B-2840 CONTRACTOR CONTRACTOR PROVIDE FR BLOCKING IN WALL AS REQ.
PLUMBING FIXTURE SCHEDULE
TYPE MARK DESCRIPTION MFR MODEL COMMENTS
B01 LAVATORY WITH ADA APRON @ TLT AMERICAN STANDARD 0958.008EC /
0062.00EC
FAUCET: AMERICAN STANDARD 6540.170
B02 SINK @ HANDWASH STATIONS ELKAY LRAD221965 FAUCET: AMERICAN STANDARD 6540.170
B03 SINK @ LAB ELKAY LRAD221965 FAUCET: SPEAKMAN SEF-1800-CA
B04 SINK @ BREAKROOM ELKAY LRAD2522653 FAUCET: AMERICAN STANDARD 6540.170
B05 TOILET AMERICAN STANDARD 3043.001 FLUSH VALVE: SLOAN 111-1.28 | TOILET SEAT: CHURCH COMMERICAL: 295SSCT
B06 DRINKING FOUNTAIN TBD TBD
B07 MOP SINK FIAT TSB3010 FAUCET: T&S B-0665-BSTR
EW1 FAUCET EMERGENCY EYEWASH SPEAKMAN SEF-1800-CA
1. RE: SHEET G001 FOR ADDITIONAL GENERAL NOTES
THAT ARE APPLICABLE.
2. REFERENCE SHEET G003-G004 FOR FIXTURE &
ACCESSORY MOUNTING HEIGHTS & LOCATION.
3. DIMENSIONS SHOWN ON THE FLOOR PLAN ARE TO THE
FACE OF GYP. BOARD/ WALL (FOG), FACE OF MASONRY
(FOM), FACE OF CONCRETE WALLS (FOC), AND COLUMN
GRID LINES, UNLESS NOTED OR SHOWN OTHERWISE.
4. DOOR OPENINGS NOT LOCATED BY DIMENSION SHALL
BE CENTERED IN WALL SHOWN OR LOCATED 4" FROM
FINISH WALL TO HINGE SIDE OF THE DOOR, ALWAYS
ALLOWING A MINIMUM OF 18" FROM THE PULL SIDE
(STRIKE SIDE) OF THE DOOR TO THE INTERSECTING
WALL, OR OTHER PROTRUDING OBJECTS.
5. ALL CLOSETS AND ALCOVES WITHOUT A SPACE
IDENTIFICATION NUMBER SHALL HAVE THE SAME
FINISHES AS THE ADJOINING SPACES.
6. ALL PUBLIC SPACES: WALLS WILL BE FINISHED WITH
5/8" GYP. BD. TO A LEVEL 4H ROLLER FINISH AND
PAINTED, UNLESS NOTED OR SPECIFIED OTHERWISE.
7. RE: DOOR SCHEDULE, FINISH SCHEDULE AND
SPECIFICATIONS FOR DOOR AND DOOR FRAME
FINISHES.
8. PROVIDE MINIMUM 1'-0" CLEAR FLOOR SPACE AT THE
PUSH SIDE OF EVERY DOOR WITH A CLOSER. PROVIDE
MINIMUM 1'-6" CLEAR AT THE PULL SIDE OF EVERY
DOOR, UNLESS SPECIFICALLY DIMENSIONED, NOTED
OR SHOWN OTHERWISE.
9. ALL WALL PARTITIONS ARE TYPE A3C INSULATED U.N.O.
10. OFOI FURNITURE SYSTEMS DASHED IN FOR CLARITY.
11. EXISTING WALLS TO REMAIN: PATCH AND REPAIR AS
REQ. TO PROVIDE LEVEL 4 FINISH. RE: FINISH PLAN FOR
WALL FINISH
GENERAL NOTES
FLOOR PLAN
DOOR, RE: /1 A111
RE
:
P
L
A
N
RE: PLAN
2/A121
3/
A
1
2
1
4/A121
5/
A
1
2
1
1'
-
4
"
TT1
GB1
GB2
PC1
MR1
SD1
EQ
EQ
PT2
B01
B05
FLOOR DRAIN,
RE: PLUMBING
3' - 0 5/8"
RE: PLAN FOR
LOCATIONS
RE: PLAN
B05
TT1
GB1
GB2
IRL6
PT29E
RBC39
RE: PLAN
MR1
B01
PC1
GB2
GB1
B05
VANITY LIGHT EQ EQ
IRL6
PT29E
RBC39
3'
-
1
0
"
RE: EQUIPMENT
PLAN FOR
LOCATIONS
RE: EQUIP PLAN
RE: PLAN
MR1
B01
SD1
IRL6
PT29E
RBC39
RE: PLAN
IRL6
PT29E
RBC39
MULL-IT-OVER CAP BY MANUF.
@ 60 STC RATING. GC TO
COORD. SIZE WITH MANUF.
INTUMESCENT LAYER FOR 1HR
RATING PER MANUF.
SOUND DEADENING
COMPOSITE BY MANUF.
FIRE CAULKING
F3
C
CONTINUOUS GYP. LAYER
1 1/2"
OPACITY FILM ON INTERIOR SIDE
OF EXISTING STOREFRONT
A6A
OPACITY FILM ON INTERIOR SIDE
OF EXISTING STOREFRONT
N.I.C.
NIC
MULL-IT-OVER CAP BY MANUF.
@ 60 STC RATING. GC TO
COORD. SIZE WITH MFR.
INTUMESCENT LAYER FOR 1HR
RATING PER MANUF.
SOUND DEADENING
COMPOSITE BY MANUF.
CONTINUOUS GYP. LAYER
EXISTING STOREFRONT
2"
F3
C
A6A
OPACITY FILM ON INTERIOR SIDE
OF EXISTING STOREFRONT
MULL-IT-OVER CAP BY MANUF.
@ 60 STC RATING. GC TO
COORD. SIZE WITH MANUF.
SOUND DEADENING
COMPOSITE BY MANUF.
OPACITY FILM ON INTERIOR SIDE
OF EXISTING STOREFRONT
F3C
A3
C
2"
MULL-IT-OVER CAP BY MANUF.
@ 60 STC RATING. GC TO
COORD. SIZE WITH MANUF.
SOUND DEADENING
COMPOSITE BY MANUF.
DOOR AS SCHED.
EXISTING STOREFRONT
F2
C
F2C
F2
C
F2C
EXISTING COLUMN
GYP. BD.
CORNER GUARD
AS SCHED.
1. RE: SHEET G001 FOR ADDITIONAL GENERAL
NOTES THAT ARE APPLICABLE.
2. RE: SHEET G003/4 ACCESSIBILITY STANDARDS
FOR MOUNTING HEIGHTS OF FIXTURES AND
ACCESSORIES.
3. RE: FINISH LEGEND AND FINISH SCHEDULE
FOR SPECIFIC FINISH INFORMATION AND
LOCATIONS.
4. WALL FINISHES SHOWN ARE FOR ACCENT
CLARIFICATION ONLY. RE: FINISH FLOOR PLAN
AND FINISH LEGEND FOR ADDITIONAL ROOM
FINISHES.
5. PROVIDE GYPSUM BOARD CONTROL JOINTS
AT DOOR HEADERS WHERE GYPSUM BOARD
EXCEEDS 30 FEET (TYP.), UNLESS SHOWN
OTHERWISE. JOINTS TO BE LINED UP WITH
BOTH SIDES OF DOOR FRAMES FOR DOORS
4'-0" AND OVER AND ALL DOORS THAT ARE
LEAD LINED.
6. ALIGN ALL WALL TILE JOINTS WITH FLOOR
TILE JOINTS, UNLESS NOTED OR SHOWN
OTHERWISE.
7. TRANSITION ALL WALL AND BASE FINISHES,
AND/ OR COLOR CHANGES AT INSIDE
CORNERS, UNLESS NOTED OTHERWISE.
CONSULT ARCHITECT FOR CLARIFICATION, IF
NECESSARY.
8. CONTINUE WALL FINISH AS SCHEDULED
BEHIND ALL FURNITURE AND EQUIPMENT,
INCLUDING UNDER OPEN COUNTERS.
9. CONTINUE WALL BASE AT ALL WALLS,
FURRED OUT COLUMNS & COLUMN COVERS,
AND AT ALL CASEWORK TOE KICKS, SIDE
PANELS, AND UNDER OPEN COUNTERS,
UNLESS NOTED OTHERWISE.
10. CONTRACTOR SHALL FIELD VERIFY ALL
DIMENSIONS PRIOR TO MILLWORK/
CASEWORK FABRICATION & INSTALLATION.
11. ALL MILLWORK/CASEWORK CONSTRUCTION
SHALL MEET AWI PREMIUM STANDARDS,
UNLESS NOTED OR SPECIFIED OTHERWISE.
12. CONTRACTOR SHALL PROVIDE & INSTALL
GROMMETS AT 48” O.C. MAX. AT ALL WORK
STATIONS WITH OPEN KNEE SPACE.
COORDINATE LOCATIONS DIRECTLY WITH
ELECTRICAL/DATA DRAWINGS FOR OUTLET
LOCATIONS. COLOR TO BE SELECTED BY
ARCHITECT.
13. CONTRACTOR SHALL PROVIDE CONCEALED
COUNTERTOP BRACKETS AT OPEN KNEE
SPACES WIDER THAN 42” (TYP.). CENTER IN
OPEN AREA AND PAINT TO MATCH WALL
COLOR, UNLESS NOTED OR SHOWN
OTHERWISE.
14. ALL EXPOSED CASEWORK/MILLWORK
SURFACES SHALL BE FINISHED TO MATCH
ADJACENT PLASTIC LAMINATE SURFACES,
UNLESS NOTED OTHERWISE.
15. ALL FILLER PANELS SHALL BE FINISHES TO
MATCH ADJACENT SURFACES AND SCRIBED
TO FIT ADJACENT WALL, UNLESS NOTED
OTHERWISE.
16. RE: EQUIPMENT DRAWINGS & SPECS. FOR
EQUIPMENT ITEMS SHOWN DASHED,
PROVIDED BY EQUIP. CONSULTANT AND/ OR
SUPPLIED BY OWNER. COORDINATE WITH
OTHER TRADES AS NECESSARY.
17. MECH. & ELEC. SYMBOLS AND OUTLETS ARE
SHOWN FOR REFERENCE ONLY. COORDINATE
LOCATIONS WITH MEP DRAWINGS. CONSULT
ARCHITECT FOR CLARIFICATION, IF
NECESSARY.
GENERAL NOTES
INTERIOR ELEVS
SHEET NUMBER
4040 N CENTRAL EXPY,
SUITE 720
DALLAS, TEXAS 75204
t 314.302.6864
www.modusarchitecture.com
FOR INFORMATION
PURPOSES ONLY. NOT TO
BE USED IN ANY CAPACITY
FOR BIDDING, PERMITTING,
OR CONSTRUCTION
REVISIONS:
SHEET NAME
ISSUE DATE:
16
2
5
L
A
N
C
A
S
T
E
R
D
R
I
V
E
GR
A
P
E
V
I
N
E
,
T
E
X
A
S
7
6
0
5
1
A121
ENLARGED
RESTROOM PLAN &
PLAN DETAILS
PE
R
M
I
T
S
E
T
CO
O
K
C
H
I
L
D
R
E
N
'
S
12/19/2024
1/2" = 1'-0"1 ENLARGED PLAN - TYP. RESTROOM
1/2" = 1'-0"2 INT. ELEV - TYP. RESTROOM
1/2" = 1'-0"3 INT. ELEV - TYP. RESTROOM
1/2" = 1'-0"4 INT. ELEV - TYP. RESTROOM
1/2" = 1'-0"5 INT. ELEV - TYP. RESTROOM
TOILET ACCESSORY SCHEDULE
TYPE MARK DESCRIPTION MFR MODEL
PROCUREMEN
T INSTALL COMMENTS
GB1 GRAB BAR BOBRICK B-6806-42 CONTRACTOR CONTRACTOR PROVIDE FR BLOCKING IN WALL AS REQ.
GB2 GRAB BAR BOBRICK B-6806x36 CONTRACTOR CONTRACTOR PROVIDE FR BLOCKING IN WALL AS REQ.
MR1 WELDED-FRAME GLASS MIRROR BOBRICK B-290 2436 CONTRACTOR CONTRACTOR PROVIDE FR BLOCKING IN WALL AS REQ.
PC1 PASS-THROUGH CABINET AMERICAN SPECIALTIES 8154 CONTRACTOR CONTRACTOR REFERENCE EQUIPMENT PLAN FOR LOCATIONS. COORDINATE MODEL WITH WALL THICKNESS
PT1 PAPER TOWEL DISPENSER GEORGIA PACIFIC ENMOTION 59466 PDC CONTRACTOR PROVIDE FR BLOCKING IN WALL AS REQ., PROVIDE POWER FOR AUTO SENSOR, RE: ELEC
PT2 PAPER TOWEL DISPENSER (STAFF) BOBRICK B-26212 PDC CONTRACTOR <varies>
SD1 SOAP DISPENSER PROVON ADX-12, 8871-06 PDC CONTRACTOR PROVIDE FR BLOCKING IN WALL AS REQ.
TT1 TOILET TISSUE DISPENSER BOBRICK B-2840 CONTRACTOR CONTRACTOR PROVIDE FR BLOCKING IN WALL AS REQ.
1 1/2" = 1'-0"6 PLAN DETAIL - WALL AT GLAZING
1 1/2" = 1'-0"8 PLAN DETAIL - WALL AT GLAZING
1 1/2" = 1'-0"7 PLAN DETAIL - WALL AT GLAZING
1 1/2" = 1'-0"9 PLAN DETAIL - WALL AT GLAZING
PLUMBING FIXTURE SCHEDULE
TYPE MARK DESCRIPTION MFR MODEL COMMENTS
B01 LAVATORY WITH ADA APRON @ TLT AMERICAN STANDARD 0958.008EC /
0062.00EC
FAUCET: AMERICAN STANDARD 6540.170
B02 SINK @ HANDWASH STATIONS ELKAY LRAD221965 FAUCET: AMERICAN STANDARD 6540.170
B03 SINK @ LAB ELKAY LRAD221965 FAUCET: SPEAKMAN SEF-1800-CA
B04 SINK @ BREAKROOM ELKAY LRAD2522653 FAUCET: AMERICAN STANDARD 6540.170
B05 TOILET AMERICAN STANDARD 3043.001 FLUSH VALVE: SLOAN 111-1.28 | TOILET SEAT: CHURCH COMMERICAL: 295SSCT
B06 DRINKING FOUNTAIN TBD TBD
B07 MOP SINK FIAT TSB3010 FAUCET: T&S B-0665-BSTR
EW1 FAUCET EMERGENCY EYEWASH SPEAKMAN SEF-1800-CA
1 1/2" = 1'-0"10 PLAN DETAIL - COLUMN WRAP
HARDWARE SCHEDULE
QTY
HARDWARE SET 1.0
DESCRIPTION CATALOG NUMBER FINISH MFR
3 Hinge, Full Mortise, Hvy Wt T4A3386 NRP 4-1/2" x 4-1/2"US32D MK
Notes: Door normally closed and locked. When valid pin code is entered at keypad door will unlock
allowing ingress. Free egress at all times.
DOORS: 133
DESCRIPTION: SGL EXT KEYPAD - CLOSER W STOP
1 Access Control Cyl Lock B AU NTB613-NR 626 YA
1 Drop Plate 3148 689 YA
1 Surface Closer 2731T 689 YA
1 Gasketing 316AV PE
1 Rain Guard 346C x Width of Frame Head PE
1 Sweep 345AV x Length Required PE
1 Threshold 2009APK x Length Required x
MSES25SS
PE
1 SFIC Core x Type Required 626 BE
QTY
HARDWARE SET 2.0
DESCRIPTION CATALOG NUMBER FINISH MFR
3 Hinge, Full Mortise TA2714 4-1/2" x 4-1/2"US26D MK
DOORS: 114, 120, 130, 131
DESCRIPTION: SGL STORAGE - CLOSER W WALL STOP
1 Storeroom or Closet Lock B AU 4705LN 626 YA
1 Surface Closer 2701 689 YA
1 Wall Stop 409 US26D RO
3 Silencer 608 RO
1 SFIC Core x Type Required 626 BE
QTY
HARDWARE SET 3.0
DESCRIPTION CATALOG NUMBER FINISH MFR
3 Hinge, Full Mortise TA2714 4-1/2" x 4-1/2"US26D MK
DOORS: 107, 126
DESCRIPTION: SGL OFFICE - CLOSER W WALL STOP
1 Entry Lock B AU 4707LN 626 YA
1 Surface Closer 2701 689 YA
1 Wall Stop 409 US26D RO
3 Silencer 608 RO
1 SFIC Core x Type Required 626 BE
QTY
HARDWARE SET 4.0
DESCRIPTION CATALOG NUMBER FINISH MFR
3 Hinge, Full Mortise TA2714 4-1/2" x 4-1/2"US26D MK
Notes: Doors normally closed and secured. Push button at reception desk allowing for ingress for users
without valid credentials after signing in/out with reception.
DOORS: 100A, 100B
DESCRIPTION: SGL CLASSROOM - ELECTRIC STRIKE W CLOSER
1 Storeroom or Closet Lock B AU 4705LN 626 YA
1 Electric Strike 1500C 630 HS
1 SMART Pac Bridge Rectifier 2005M3 HS
3 Surface Closer 2701 YA
1 Kick Plate K1050 10”x 2”LDW US26D RO
689
1 Wall Stop 409 US26D RO
3 Silencer 608 RO
1 ElectroLynx Harness QC-C**** x Length Required MK
1 Power Supply AQD1 SU
1 Wiring Diagram Elevation and Point to Point as
Specified
OT
1 Push Button Release Provided by Other OT
1 SFIC Core x Type Required BE626
QTY
HARDWARE SET 5.0
DESCRIPTION CATALOG NUMBER FINISH MFR
3 Hinge, Full Mortise TA2714 4-1/2" x 4-1/2"US26D MK
DOORS: 102, 111, 124, 129, 132
DESCRIPTION: SGL PRIVACY - CLOSER W WALL STOP
1 Privacy AU YPL02 626 YA
1 Surface Closer 2701 689 YA
1 Wall Stop 409 US26D RO
3 Silencer 608 RO
QTY
HARDWARE SET 6.0
DESCRIPTION CATALOG NUMBER FINISH MFR
3 Hinge, Full Mortise TA2714 4-1/2" x 4-1/2"US26D MK
DOORS: 104, 105, 106, 108, 109, 110, 113, 115, 116, 117, 118, 119, 121, 122, 123
DESCRIPTION: SGL PASSAGE - WALL STOP
1 Passage Latch AU 4701LN 626 YA
1 Wall Stop 409 US26D RO
3 Silencer 608 RO
QTY
HARDWARE SET 7.0
DESCRIPTION CATALOG NUMBER FINISH MFR
3 Hinge, Full Mortise TA2714 4-1/2" x 4-1/2"US26D MK
DOORS: 125
DESCRIPTION: SGL PASSAGE - CLOSER W WALL STOP
1 Passage Latch AU 4701LN 626 YA
1 Wall Stop 409 US26D RO
3 Silencer 608 RO
1 Surface Closer 2701 689 YA
QTY
HARDWARE SET 8.0
DESCRIPTION CATALOG NUMBER FINISH MFR
3 Hinge, Full Mortise TA2714 4-1/2" x 4-1/2"US26D MK
DOORS: 112
DESCRIPTION: SGL PASSAGE - OVERHEAD STOP
1 Passage Latch AU 4701LN 626 YA
3 Silencer 608 RO
1 Surf Overhead Stop 10-x36 652 RF
PE
R
S
C
H
E
D
U
L
E
PER SCHEDULE
F DOOR TYPESSINGLE DOOR
DOUBLE DOOR FF
PE
R
S
C
H
E
D
U
L
E
PER SCHEDULE
NV2
4"6"
10
"
2'
-
0
"
8"
VA
R
I
E
S
6"
RE: SCHED
4"
4"
4"
10
"
GF
T
T
PE
R
S
C
H
E
D
U
L
E
TY
P
.
2"
2" TYP.
PER SCHEDULE
FRAME TYPESF1
PE
R
S
C
H
E
D
U
L
E
2"
2"
PER SCHEDULE
F2
RE: PLAN
T
A
4"1/2"
1/2"
4"1/2"
1/2"
1/
2
"
2"
PE
R
W
A
L
L
T
Y
P
E
DOOR AS SCHED.
HM DOOR FRAME
3 5/8-INCH METAL STUDS
@ 16-INCHES O.C.
INTERIOR 5/8-INCH
TYPE X GYP. BD.
3 5/8-INCH METAL STUDS
@ 16-INCHES O.C.
HM DOOR FRAME
DOOR AS SCHED.
INTERIOR 5/8-INCH
TYPE X GYP. BD.
PER WALL TYPE
2"2"1/
2
"
2"
1/2"
HM DOOR FRAME
3 5/8-INCH BOX BEAM
HEADER
INTERIOR 5/8-INCH
TYPE X GYP. BD.
3 5/8-INCH METAL
STUDS @ 16-
INCHES O.C.
DOOR AS SCHED.
1. REFERENCE SPECIFICATIONS FOR ADDITIONAL
DOOR AND DOOR HARDWARE INFORMATION.
2. G.C. TO COORDINATE AND REVIEW ALL HARDWARE
SUBMITTALS WITH ARCHITECT AND TENANT PRIOR
TO PLACING DOOR HARDWARE ORDER.
3. ALL DOORS AND DOOR HARDWARE SHALL BE
INSTALLED IN COMPLIANCE WITH THE TEXAS
ACCESSIBILITY STANDARDS.
4. SHOULD A MODIFICATION TO A RATED FRAME BE
REQUIRED, NOTIFY ARCHITECT IMMEDIATELY.
MODIFICATIONS TO EXISTING RATED FRAMES ARE
UNACCEPTABLE.
5. THE CONTRACTOR SHALL INSTALL DOORS AND
FRAMES PER MANUFACTURER'S
RECOMMENDATIONS.
6. G.C. TO COORDINATE KEY SCHEDULE (IE: MASTER |
SUB-MASTER) WITH BUILDING MANAGEMENT AND
TENANT.
7. RE-KEY EXISTING HARDWARE TO COORDINATE WITH
NEW HARDWARE.
8. ALL CLOSERS SHALL BE CONCEALED IN FRAME OR
OVERHEAD U.N.O. RE: SCHED.
9. ADJUST ALL CLOSERS TO MEET ADAAG/TAS
GUIDELINES.
10. CONTRACTOR TO ENSURE DRYWALL EDGE AND
STUD ARE NOT EXPOSED AT DOOR STRIKE
LOCATIONS.
11. CONTRACTOR TO SUPPLY AND INSTALL PANIC
HARDWARE/FIRE EXIT DEVICES AS REQUIRED BY
CODE.
12. WD REFERS TO SOLID CORE WOOD DOOR, RE:
SPECIFICATIONS RE: FINISH LEGEND FOR DOOR
FINISH.
13. FINISH OF HM DOOR FRAMES TO BE PT135E U.N.O.
RE: FINISH LEGEND.
GENERAL NOTES
DOORS
T.O DOOR FRAME
RE: DOOR SCHEDULE
FINISH FLOOR ELEVATION
RE: PLAN
BACKER ROD AND
SEALENT, BOTH SIDES
1/4" SHIM
(AS REQ.)
ALUM. THRESHOLD
SET IN FULL BED OF
MASTIC
DRIP EDGE
HOLLOW METAL
DOOR AND FRAME,
PAINTED
4 1/2"
1/
4
"
M
A
X
.
FLEXIBLE FLASHING
MEMBRANE TO CREATE
CONTINUOUS WATER TIGHT
CONDITION TO ENGAGE
MULLION HEAD, JAMB AND
SILLS, TYP.
SLOPE BUILDING SLAB
1/4" PER FOOT IN
CONDITIONS WHERE
STOREFRONT IS HELD
BACK. COORD. PRIOR
TO POURING
BUILDING SLAB
MA
X
.
1/
4
"
D
R
O
P
4 1/2"
1/
4
"
M
A
X
.
EXISTING EXTERIOR
ASSEMBLY
FLASHING AS REQ. IN
EXISTING ASSEMBLY
SLOPE SIDEWALK
1/4" PER FT. FOR
5'-0" FROM DOOR
DOOR LEGEND
T 1/4" TEMPERED GLASS
A FROST FILM 'F1'
RE: FINISH LEGEND
FINISH FLOOR ELEVATION
RE: PLAN
MA
X
1/
4
"
D
R
O
P
SLOPE SIDEWALK
1/4" PER FT. FOR
5'-0" FROM DOOR
1" INSULATED
GLASS, RE: SPECS
ALUM. THRESHOLD
SET IN FULL BED OF
MASTIC
BACKER ROD AND
SEALENT, BOTH
SIDES
1/
4
"
M
A
X
1" INSULATED
TEMPERED GLASS
T.O. DOOR FRAME
RE: DOOR SCHEDULE
WEATHER STRIP
AS REQ.
WEATHER STRIP AS
REQ.
FLEXIBLE FLASHING
MEMBRANE TO CREATE
CONTINUOUS WATER TIGHT
CONDITION TO ENGAGE
MULLION HEAD, JAMB AND
SILLS, TYP.
SLOPE BUILDING SLAB
1/4" PER FOOT IN
CONDITIONS WHERE
STOREFRONT IS HELD
BACK. COORD. PRIOR
TO POURING BUILDING
SLAB
1/
4
"
M
A
X
1/4" SHIM
(AS REQ.)
EXISTING EXTERIOR
ASSEMBLY
FLASHING AS REQ. IN
EXISTING ASSEMBLY
BACKER ROD AND
SEALENT, BOTH SIDES
1/4" SHIM
(AS REQ.)
HOLLOW METAL
DOOR AND FRAME,
PAINTED
4 1/2"
FLEXIBLE FLASHING
MEMBRANE TO CREATE
CONTINUOUS WATER TIGHT
CONDITION TO ENGAGE
MULLION HEAD, JAMB AND
SILLS, TYP.
4 1/2"
EXISTING EXTERIOR
ASSEMBLY
CONTINUOUS WEATHER
BARRIER FROM EXISTING
ASSEMBLY TO WRAP NEW
JAMB CORNER
1" INSULATED
TEMPERED GLASS
WEATHER STRIP
AS REQ.
FLEXIBLE FLASHING
MEMBRANE TO CREATE
CONTINUOUS WATER TIGHT
CONDITION TO ENGAGE
MULLION HEAD, JAMB AND
SILLS, TYP.
1/4" SHIM
(AS REQ.)
EXISTING EXTERIOR
ASSEMBLY
CONTINUOUS WEATHER
BARRIER FROM EXISTING
ASSEMBLY TO WRAP NEW
JAMB CORNER
SHEET NUMBER
4040 N CENTRAL EXPY,
SUITE 720
DALLAS, TEXAS 75204
t 314.302.6864
www.modusarchitecture.com
FOR INFORMATION
PURPOSES ONLY. NOT TO
BE USED IN ANY CAPACITY
FOR BIDDING, PERMITTING,
OR CONSTRUCTION
REVISIONS:
SHEET NAME
ISSUE DATE:
16
2
5
L
A
N
C
A
S
T
E
R
D
R
I
V
E
GR
A
P
E
V
I
N
E
,
T
E
X
A
S
7
6
0
5
1
A511
DOOR SCHEDULE
AND DETAILS
PE
R
M
I
T
S
E
T
CO
O
K
C
H
I
L
D
R
E
N
'
S
12/19/2024
1 1/2" = 1'-0"2 HM DOOR JAMB - TYP.
1 1/2" = 1'-0"1 HM DOOR HEAD - TYP.
DOOR SCHEDULE
MARK ROOM
DOOR DOOR FRAME
RATING
DETAILS
HARDWARE REMARKSWIDTH HEIGHT MATERIAL TYPE MATERIAL TYPE HEAD JAMB
100A WAITING 3' - 0" 7' - 0" WD NV2 HM F2 -- 1/A511 2/A511 4.0 1
100B WAITING 3' - 0" 7' - 0" WD NV2 HM F2 -- 1/A511 2/A511 4.0 1
101 RISER ROOM 3' - 0" 7' - 0" HM F HM F1 -- 3/A511 5/A511 - 4,5,6
102 TLT 3' - 0" 7' - 0" WD F HM F1 -- 1/A511 2/A511 5.0
104 EXAM 01 3' - 0" 7' - 0" WD F HM F1 -- 1/A511 2/A511 6.0
105 EXAM 02 3' - 0" 7' - 0" WD F HM F1 -- 1/A511 2/A511 6.0
106 EXAM 03 3' - 0" 7' - 0" WD F HM F1 -- 1/A511 2/A511 6.0
107 SHARED OFFICE 3' - 0" 7' - 0" WD F HM F1 -- 1/A511 2/A511 3.0
108 EXAM 04 3' - 0" 7' - 0" WD F HM F1 -- 1/A511 2/A511 6.0
109 EXAM 05 3' - 0" 7' - 0" WD F HM F1 -- 1/A511 2/A511 6.0
110 EXAM 06 3' - 0" 7' - 0" WD F HM F1 -- 1/A511 2/A511 6.0
111 STAFF TLT 3' - 0" 7' - 0" WD F HM F1 -- 1/A511 2/A511 5.0
112 BREAKROOM 3' - 0" 7' - 0" WD F HM F1 -- 1/A511 2/A511 8.0
113 EXAM 07 3' - 0" 7' - 0" WD F HM F1 -- 1/A511 2/A511 6.0
114 IT/ELEC 3' - 0" 7' - 0" WD F HM F1 -- 1/A511 2/A511 2.0
115 EXAM 08 3' - 0" 7' - 0" WD F HM F1 -- 1/A511 2/A511 6.0
116 EXAM 09 3' - 0" 7' - 0" WD F HM F1 -- 1/A511 2/A511 6.0
117 EXAM 10 3' - 0" 7' - 0" WD F HM F1 -- 1/A511 2/A511 6.0
118 EXAM 11 3' - 0" 7' - 0" WD F HM F1 -- 1/A511 2/A511 6.0
119 EXAM 12 3' - 0" 7' - 0" WD F HM F1 -- 1/A511 2/A511 6.0
120 STORAGE 3' - 0" 7' - 0" WD F HM F1 -- 1/A511 2/A511 2.0
121 EXAM 13 3' - 0" 7' - 0" WD F HM F1 -- 1/A511 2/A511 6.0
122 EXAM 14 3' - 0" 7' - 0" WD F HM F1 -- 1/A511 2/A511 6.0
123 EXAM 15 3' - 0" 7' - 0" WD F HM F1 -- 1/A511 2/A511 6.0
124 NURSING 3' - 0" 7' - 0" WD F HM F1 -- 1/A511 2/A511 5.0
125 RECEPTION 3' - 0" 7' - 0" WD F HM F1 -- 1/A511 2/A511 7.0
126 OFFICE 3' - 0" 7' - 0" WD F HM F1 -- 1/A511 2/A511 3.0
129 TLT 3' - 0" 7' - 0" WD F HM F1 -- 1/A511 2/A511 5.0
130 STORAGE 3' - 0" 7' - 0" WD F HM F1 -- 1/A511 2/A511 2.0
131 EVS 3' - 0" 7' - 0" WD F HM F1 -- 1/A511 2/A511 2.0
132 TLT 3' - 0" 7' - 0" WD F HM F1 -- 1/A511 2/A511 5.0
133 EXTERIOR 3' - 0" 7' - 0" AL GF AL F1 -- 4/A511 6/A511 1.0 2,3,6
DOOR SCHEDULE REMARKS:
1. REMOTE RELEASE BELOW RECEPTION COUNTER.
2. ACCESSED FROM EXTERIOR VIA KEYPAD LOCK.
3. AL DOOR AND FRAME FINISH TO BE CLEAR ANODIZED.
4. HM DOOR FRAME TO BE PT09, RE: FINISH LEGEND.
5. COORDINATE HARDWARE WITH LANDLORD
6. PROVIDE AS SEPARATE LINE ITEM ,RE: SCHEDULE OF ALTERNATES
3" = 1'-0"3 HM DOOR HEAD/SILL EXTERIOR
3" = 1'-0"4 AL DOOR HEAD/SILL EXTERIOR
3" = 1'-0"5 HM DOOR JAMB EXTERIOR
3" = 1'-0"6 AL DOOR JAMB EXTERIOR DETAIL
1. RE: SHEET G001 FOR ADDITIONAL GENERAL
NOTES THAT ARE APPLICABLE.
2. DIMENSIONS SHOWN ON THE REFLECTED
CEILING PLANS ARE TO THE FACE OF GYP.
BOARD (FOG), AND COLUMN GRID LINES,
UNLESS NOTED OR SHOWN OTHERWISE.
3. ALL ACOUSTICAL TILE CEILINGS TO BE 9'-0"
A.F.F., UNLESS NOTED OTHERWISE.
4. ALL CEILING HEIGHTS AS SHOWN ON PLANS
AND DETAILS ARE FROM SLAB OR TILE FLOOR
(FINISHED FLOOR) TO FINISH CEILING.
5. AT ALL GYP. BD. SOFFITS: EXTEND GYP. BD.
UP 6 INCHES ABOVE ADJACENT CEILING.
6. RE: DETAILS FOR ADDITIONAL CONDITIONS
AND CEILING HEIGHT INFORMATION.
7. RE: FINISH FLOOR PLAN AND FINISH LEGEND
FOR ROOM CEILING FINISHES.
8. CEILING TILES/GRID TO BE CENTERED IN THE
ROOM, UNLESS NOTED OTHERWISE.
9. RECESSED LIGHTING, SPEAKERS, SMOKE
DETECTORS, ETC. AND PENDANT LIGHT
FIXTURES - SHALL BE CENTERED IN CEILING
TILE OR GYP. BD. CEILING, UNLESS NOTED
OTHERWISE.
10. RE: INTERIOR ELEVATIONS FOR LOCATION OF
WALL MOUNTED LIGHT FIXTURES.
11. RE: ELECTRICAL SHEETS AND
SPECIFICATIONS FOR DETAILED INFORMATION
ON LIGHT FIXTURE SCHEDULE.
12. RE: MECHANICAL SHEETS AND
SPECIFICATIONS FOR DETAILED INFORMATION
ON DIFFUSERS.
13. COORDINATE ALL CEILING MOUNTED
EQUIPMENT WITH CASEWORK BELOW.
14. IF THERE IS A CONFLICT BETWEEN ANY
ABOVE- CEILING MECHANICAL / ELECTRICAL /
PLUMBING WORK & THE SCHEDULED OR
SHOWN CEILING HEIGHT, CONTACT THE
ARCHITECT IMMEDIATELY FOR CLARIFICATION
16. THE CONTRACTOR SHALL COMPARE THIS
REFLECTED CEILING PLAN WITH ELECTRICAL
LIGHTING PLANS, MECHANICAL SUPPLY,
RETURN, AND EXHAUST PLANS. THE
CONTRACTOR SHALL REPORT ANY
OMISSIONS OR INCONSISTENCIES TO THE
ARCHITECT.
17. SEE ELECTRICAL DRAWINGS FOR THE
LOCATIONS OF CEILING MOUNTED SMOKE
DETECTORS, SPEAKERS, NURSE CALL DOME
LIGHTS, EXIT SIGNAGE, FIRE ALARM DEVICES,
WALL MOUNTED EXIT LIGHTS, ETC.
18. FOR FURTHER DIMENSIONS SEE LARGE
SCALE PLANS, SECTIONS, ELEVATIONS, AND
DETAILS.
19. COORDINATE GYPSUM BOARD FURR DOWN
HEIGHTS WITH FULL HEIGHT CABINETS AND
INTERIOR ELEVATIONS.
GENERAL NOTES
RCP
CEILING TYPE
SUPPLY AIR GRILLE
REFER TO MECHANICAL DRAWINGS
FOR ADDITIONAL INFORMATION
SUSPENDED 2' X 2' ACOUSTICAL
CEILING SYSTEM
CEILING DETAIL / SECTION TAG
GYPSUM BOARD CEILING
RETURN AIR GRILLE
REFER TO MECHANICAL DRAWINGS
FOR ADDITIONAL INFORMATION
1
A101
SIM
RCP LEGEND
LIGHT FIXTURE
RECESSED CAN, RE: ELEC.
2X2 LIGHT FIXTURE
DIRECT/INDIRECT, RE: ELEC.
ITEM DESCRIPTION
2X4 LIGHT FIXTURE
DIRECT/INDIRECT, RE: ELEC.
EXIT SIGN
UNDER CABINET LIGHTING,
RE: ELEC.
XXX
X' -X"CEILING HEIGHT
PROVIDE 3 1/2" BATT INSULATION ABOVE CEILING
IN ENTIRE ROOM WHERE INDICATED
1
EXISTING ROOF HATCH ABOVE CEILING. PRESERVE
ACCESS. GC TO DESIGN BUILD JOIST PLATFORM FOR
ROOF HATCH ACCESS.
2
NOTES BY NUMBER
RCP
3 DELEGATED DESIGN - GC TO COORDINATE WOOD
OR CFMF PLATFORM ABOVE CEILING TO PROVIDE
ACCESS TO EXISTING ROOF HATCH WITH A DEAD
LOAD OF 30 PSF AND A LIVE LOAD OF 50 PSF
PERFORMANCE CRITERIA.
1
ACT
10' -0"
GYP
8' -6"
ACT
8' -6"
8' - 4"
8' - 10"
ACT
8' -6"
EQ EQ EQ EQ
EQ
EQ
EQ
EQ
EQ
EQ
EQ EQ
EQ
EQ
EQ
EQ
EQ
EQ
EQ
EQ
N.I.C.
N.I.C.
8' - 4"
8' - 4"
GYP
8' -0"
GYP
7' -10"
GYP
8' -0"
EQ EQ
EQ
EQ
3'
-
6
7
/
8
"
4' - 5 1/8"
EQ
EQ
EQ
EQ
EQ EQ
EQ EQ EQ EQ
18' - 0"
30
'
-
0
"
2'
-
3
"
3'
-
7
1
/
8
"
2' - 3"
EQ
EQ
EQ
EQ
EQ
EQ
EQ
EQ EQ
EQ EQ
EQ EQ
2'
-
0
"
EQ
EQ
EQ EQ
3'
-
4
"
EQ
EQ
EQ EQ
1' - 7 3/4"
GYP
7' -2"
GYP
8' -0"
GYP
9' -6"
8' - 10"
8' - 10"
119
EXAM 12
120
STORAGE
121
EXAM 13
122
EXAM 14
118
EXAM 11
117
EXAM 10
116
EXAM 09
115
EXAM 08
114
IT/ELEC
113
EXAM 07
110
EXAM 06
106
EXAM 03
105
EXAM 02
104
EXAM 01
111
STAFF TLT
112
BREAKROOM
127
MA
STATION
109
EXAM 05
108
EXAM 04
123
EXAM 15 124
NURSING
100
WAITING
128
LAB
125
RECEPTION
107
SHARED
OFFICE
103
VITALS
132
TLT
129
TLT
126
OFFICE
GYP
8' -0"
ACT
9' -1"
E Q
E Q
3' - 6"
2' - 0"
EQ EQ
EQ EQ
EQ
EQ
7'
-
0
"
2' - 2"2' - 2"
EQ EQ
1'
-
8
"
1'
-
8
"
1' - 8"1' - 8"
1'
-
8
"
1'
-
8
"
EQ EQ
1'
-
4
"
130
STORAGE
102
TLT
131
EVS
101
RISER
ROOM
1'
-
8
"
1'
-
8
"
EQ
EQ
7
A631
7
A631
5
A631
5
A631
7
A631
8
A631
7
A631
5
A631
3
A631
3
A631
3
A631
3
A631
EQ EQ 8
A631
5
A631
1
1
111
1
1111111
1
1
4
A631
4
A631
9
A631
6
A631
4' - 0"4' - 0"
EQ
EQ
GYP
8' -10"
8
A631
5
A631
7
A631
6
A631
5
A631
6
A631
6
A631
GYP
7' -10"
EQ EQ
EQ
EQ
2
AL
I
G
N
ALIGN 5
A631
GYP
9' -6"
8
A631
7
A631
7
A631
7
A631
5
A631
3
A631
7
A631
7
A631
13' - 3 1/2"
ALIGN
ALIGN
AL
I
G
N
2' - 0"2'
-
0
"
2'
-
0
"
OTS
OTS
GYP
9' -0"
8' - 10"
8' - 10"
2'
-
0
"
OTS
GYP
9' -0"
GYP
9' -0"
GYP
9' -0"
5
A631
3
EQ EQ
2'
-
0
"
3'
-
6
7
/
8
"
GYP
8' -6"
GYP
8' -6"GYP
8' -0"
2'
-
6
"
1' - 8"
1'
-
8
"
2' - 6"
2' - 6"
1'
-
8
"
2' - 6"
1'
-
8
"
SIM
5
A631
SIM
2X2 / 2X4 ACOUSTICAL CEILING SYSTEM
LIGHT FIXTURE SCHEDULE
DESCRIPTION
LAY-IN
MOUNTING
LITHONIA LIGHTING
MFR
2BLT4
TYPE
TYPICAL 2X4
PROVIDE 2X2 IN WAITING
COMMENTS
RECESSED CAN LIGHTS RECESSED LITHONIA LIGHTING 6JBK RD TYPICAL 6" CAN LIGHT IN GYP CEILING
SEMI-RECESSED DECORATIVE CAN LIGHT RECESSED - -PROVIDE ALLOWANCE FOR (5) DECORATIVE
FIXTURES AT RECEPTION DESK
LED LIGHT FIXTURE SUSPENDED LITHONIA LIGHTING CLX PROVIDE AT EVS AND IT/ELEC
UNDERCABINET LED LIGHT FIXTURE MOUNTED LITHONIA LIGHTING UCEL TYPICAL UNDER CABINET LIGHT FIXTURE @ LENGTH
OF UPPER CABINETS WHERE INDICATED ON RCP
WALL MOUNTED LED LIGHT FIXTURE MOUNTED ASL DOV PROVIDE (1) FIXTURE ABOVE MIRROR IN ALL TOILET
ROOMS, RE: A121
SHEET NUMBER
4040 N CENTRAL EXPY,
SUITE 720
DALLAS, TEXAS 75204
t 314.302.6864
www.modusarchitecture.com
FOR INFORMATION
PURPOSES ONLY. NOT TO
BE USED IN ANY CAPACITY
FOR BIDDING, PERMITTING,
OR CONSTRUCTION
REVISIONS:
SHEET NAME
ISSUE DATE:
16
2
5
L
A
N
C
A
S
T
E
R
D
R
I
V
E
GR
A
P
E
V
I
N
E
,
T
E
X
A
S
7
6
0
5
1
A611
REFLECTED
CEILING PLAN
PE
R
M
I
T
S
E
T
CO
O
K
C
H
I
L
D
R
E
N
'
S
12/19/2024
PLAN
NORTH
TRUE
NORTH
1/4" = 1'-0"1 REFLECTED CEILING PLAN
MI
N
.
6"
BRACE TO STRUCTURE
AS REQUIRED
PER R.C.P.
AFF
PER R.C.P.
AFF
MI
N
.
6"
1"1"
CEILING AS
SCHED.
INTERIOR 5/8-INCH
TYPE X GYP. BD.
CEILING AS
SCHED.
3 5/8-INCH METAL
STUDS @ 16-INCHES
O.C.
MI
N
.
6"
WALL PER
SCHEDULE
PER R.C.P.
PER R.C.P.
LIGHT WHERE
APPLICABLE: RE. MEP
CEILING AS SCHED.
5/8" GYP. BD. OVER METAL
STUDS
3 5/8-INCH METAL STUDS @
16-INCHES O.C.
MI
N
.
6"
PER R.C.P.
MI
N
.
6"
PER R.C.P.
PER R.C.P.
PER R.C.P.
BRACE TO STRUCTURE
AS REQUIRED
CEILING AS SCHED.CEILING AS SCHED.
3 5/8-INCH METAL
STUDS @ 16-
INCHES O.C.
INTERIOR 5/8-INCH
TYPE X GYP. BD.
PER R.C.P.
AFF
PARTITION AS SCHED.
CEILING AS SCHED.
METAL EDGE TRIM
LOOSE BATT INSULATION
ON ACT AS INDICATED IN
RCP NOTES
HUNG CEILING WIRE PER MFR.PARTITION AS SCHED.
RE: FLOOR PLAN
PER R.C.P.
INT. GYP. CEILING
AS SCHED.
HUNG CEILING WIRE
PER MFR.
RE
:
R
C
P
RE
:
I
N
T
.
E
L
E
V
A
T
I
O
N
S
PARTITION AS SCHED.
RE: FLOOR PLAN
5/8" GYP. BD.
OVER METAL
STUDS
BUILT IN CASEWORK
RE: ELEVATION
CEILING AS SCHED.
BRACE AS REQD.
PER R.C.P.
VERIFY PER CASEWORK VENDOR
U.N.O
1"
4"
VERIFY PER CASEWORK VENDOR
VERIFY W/CASEWORK DIM
1"
PE
R
I
N
T
.
EL
E
V
A
T
I
O
N
CASEWORK PER INT.
ELEVATION
PARTITION AS SCHED.
RE: FLOOR PLAN
5/8" GYP. BD. OVER
METAL STUDS
BUILT IN CASEWORK
RE: ELEVATION
BRACE AS REQD.
5/8" GYP. BD. OVER
METAL STUDS
WP01-A
MI
N
.
6"
RE: RCP
CEILING AS
SCHED.
5/8" GYP. BD. OVER
METAL STUDS
3 5/8-INCH METAL STUDS
@ 16-INCHES O.C.
PER R.C.P.
PER R.C.P.
PER R.C.P
PER R.C.P
INTERIOR 5/8-INCH
TYPE X GYP. BD.
ACOUSTICAL PANEL
CEILING W/ EXPOSED GRID
TRANSITION MOLDING
PER ACT MFR.
ROLLER SHADE
RE: RCP FOR
LOCATIONS AND
COORD. WITH MFR.
FOR ROLLER SHADE
HOUSING SIZE
PER R.C.P.
CEILING AS SCHED.
SUSPENSION WALL
ANGLE
EXISTING
STOREFRONT
EXISTING WALL
ASSEMBLY
FIRE RETARDANT
WD BLOCKING
HUNG CEILING WIRE
PER MFR.
ALIGN
1. RE: SHEET G001 FOR ADDITIONAL GENERAL
NOTES THAT ARE APPLICABLE.
2. DIMENSIONS SHOWN ON THE REFLECTED
CEILING PLANS ARE TO THE FACE OF GYP.
BOARD (FOG), AND COLUMN GRID LINES,
UNLESS NOTED OR SHOWN OTHERWISE.
3. ALL ACOUSTICAL TILE CEILINGS TO BE 9'-0"
A.F.F., UNLESS NOTED OTHERWISE.
4. ALL CEILING HEIGHTS AS SHOWN ON PLANS
AND DETAILS ARE FROM SLAB OR TILE FLOOR
(FINISHED FLOOR) TO FINISH CEILING.
5. AT ALL GYP. BD. SOFFITS: EXTEND GYP. BD.
UP 6 INCHES ABOVE ADJACENT CEILING.
6. RE: DETAILS FOR ADDITIONAL CONDITIONS
AND CEILING HEIGHT INFORMATION.
7. RE: FINISH FLOOR PLAN AND FINISH LEGEND
FOR ROOM CEILING FINISHES.
8. CEILING TILES/GRID TO BE CENTERED IN THE
ROOM, UNLESS NOTED OTHERWISE.
9. RECESSED LIGHTING, SPEAKERS, SMOKE
DETECTORS, ETC. AND PENDANT LIGHT
FIXTURES - SHALL BE CENTERED IN CEILING
TILE OR GYP. BD. CEILING, UNLESS NOTED
OTHERWISE.
10. RE: INTERIOR ELEVATIONS FOR LOCATION OF
WALL MOUNTED LIGHT FIXTURES.
11. RE: ELECTRICAL SHEETS AND
SPECIFICATIONS FOR DETAILED INFORMATION
ON LIGHT FIXTURE SCHEDULE.
12. RE: MECHANICAL SHEETS AND
SPECIFICATIONS FOR DETAILED INFORMATION
ON DIFFUSERS.
13. COORDINATE ALL CEILING MOUNTED
EQUIPMENT WITH CASEWORK BELOW.
14. IF THERE IS A CONFLICT BETWEEN ANY
ABOVE- CEILING MECHANICAL / ELECTRICAL /
PLUMBING WORK & THE SCHEDULED OR
SHOWN CEILING HEIGHT, CONTACT THE
ARCHITECT IMMEDIATELY FOR CLARIFICATION
16. THE CONTRACTOR SHALL COMPARE THIS
REFLECTED CEILING PLAN WITH ELECTRICAL
LIGHTING PLANS, MECHANICAL SUPPLY,
RETURN, AND EXHAUST PLANS. THE
CONTRACTOR SHALL REPORT ANY
OMISSIONS OR INCONSISTENCIES TO THE
ARCHITECT.
17. SEE ELECTRICAL DRAWINGS FOR THE
LOCATIONS OF CEILING MOUNTED SMOKE
DETECTORS, SPEAKERS, NURSE CALL DOME
LIGHTS, EXIT SIGNAGE, FIRE ALARM DEVICES,
WALL MOUNTED EXIT LIGHTS, ETC.
18. FOR FURTHER DIMENSIONS SEE LARGE
SCALE PLANS, SECTIONS, ELEVATIONS, AND
DETAILS.
19. COORDINATE GYPSUM BOARD FURR DOWN
HEIGHTS WITH FULL HEIGHT CABINETS AND
INTERIOR ELEVATIONS.
GENERAL NOTES
RCP
SHEET NUMBER
4040 N CENTRAL EXPY,
SUITE 720
DALLAS, TEXAS 75204
t 314.302.6864
www.modusarchitecture.com
FOR INFORMATION
PURPOSES ONLY. NOT TO
BE USED IN ANY CAPACITY
FOR BIDDING, PERMITTING,
OR CONSTRUCTION
REVISIONS:
SHEET NAME
ISSUE DATE:
16
2
5
L
A
N
C
A
S
T
E
R
D
R
I
V
E
GR
A
P
E
V
I
N
E
,
T
E
X
A
S
7
6
0
5
1
A631
CEILING DETAILS
PE
R
M
I
T
S
E
T
CO
O
K
C
H
I
L
D
R
E
N
'
S
12/19/2024
1 1/2" = 1'-0"3 CEILING DTL - HEADER
1 1/2" = 1'-0"5 CEILING DTL - WALL @ SOFFIT & LAY-IN CLNG
1 1/2" = 1'-0"6 CEILING DTL - SOFFIT
1 1/2" = 1'-0"1 CEILING DTL - WALL @ LAY-IN CLNG
1 1/2" = 1'-0"2 CEILING DTL - WALL @ GYP CLNG
1 1/2" = 1'-0"7 CEILING DTL - MILLWORK FURRDOWN
1 1/2" = 1'-0"8 CEILING DTL - GYP CLG AND MILLWORK FURRDOWN
1 1/2" = 1'-0"9 CEILING DTL - ACT TO GYP
1 1/2" = 1'-0"4 CEILING DTL - ROLLER SHADES
1. RE: SHEET G001 FOR ADDITIONAL GENERAL
NOTES THAT ARE APPLICABLE.
2. RE: SHEET G003/4 ACCESSIBILITY STANDARDS
FOR MOUNTING HEIGHTS OF FIXTURES AND
ACCESSORIES.
3. RE: FINISH LEGEND AND FINISH SCHEDULE
FOR SPECIFIC FINISH INFORMATION AND
LOCATIONS.
4. WALL FINISHES SHOWN ARE FOR ACCENT
CLARIFICATION ONLY. RE: FINISH FLOOR PLAN
AND FINISH LEGEND FOR ADDITIONAL ROOM
FINISHES.
5. PROVIDE GYPSUM BOARD CONTROL JOINTS
AT DOOR HEADERS WHERE GYPSUM BOARD
EXCEEDS 30 FEET (TYP.), UNLESS SHOWN
OTHERWISE. JOINTS TO BE LINED UP WITH
BOTH SIDES OF DOOR FRAMES FOR DOORS
4'-0" AND OVER AND ALL DOORS THAT ARE
LEAD LINED.
6. ALIGN ALL WALL TILE JOINTS WITH FLOOR
TILE JOINTS, UNLESS NOTED OR SHOWN
OTHERWISE.
7. TRANSITION ALL WALL AND BASE FINISHES,
AND/ OR COLOR CHANGES AT INSIDE
CORNERS, UNLESS NOTED OTHERWISE.
CONSULT ARCHITECT FOR CLARIFICATION, IF
NECESSARY.
8. CONTINUE WALL FINISH AS SCHEDULED
BEHIND ALL FURNITURE AND EQUIPMENT,
INCLUDING UNDER OPEN COUNTERS.
9. CONTINUE WALL BASE AT ALL WALLS,
FURRED OUT COLUMNS & COLUMN COVERS,
AND AT ALL CASEWORK TOE KICKS, SIDE
PANELS, AND UNDER OPEN COUNTERS,
UNLESS NOTED OTHERWISE.
10. CONTRACTOR SHALL FIELD VERIFY ALL
DIMENSIONS PRIOR TO MILLWORK/
CASEWORK FABRICATION & INSTALLATION.
11. ALL MILLWORK/CASEWORK CONSTRUCTION
SHALL MEET AWI PREMIUM STANDARDS,
UNLESS NOTED OR SPECIFIED OTHERWISE.
12. CONTRACTOR SHALL PROVIDE & INSTALL
GROMMETS AT 48” O.C. MAX. AT ALL WORK
STATIONS WITH OPEN KNEE SPACE.
COORDINATE LOCATIONS DIRECTLY WITH
ELECTRICAL/DATA DRAWINGS FOR OUTLET
LOCATIONS. COLOR TO BE SELECTED BY
ARCHITECT.
13. CONTRACTOR SHALL PROVIDE CONCEALED
COUNTERTOP BRACKETS AT OPEN KNEE
SPACES WIDER THAN 42” (TYP.). CENTER IN
OPEN AREA AND PAINT TO MATCH WALL
COLOR, UNLESS NOTED OR SHOWN
OTHERWISE.
14. ALL EXPOSED CASEWORK/MILLWORK
SURFACES SHALL BE FINISHED TO MATCH
ADJACENT PLASTIC LAMINATE SURFACES,
UNLESS NOTED OTHERWISE.
15. ALL FILLER PANELS SHALL BE FINISHES TO
MATCH ADJACENT SURFACES AND SCRIBED
TO FIT ADJACENT WALL, UNLESS NOTED
OTHERWISE.
16. RE: EQUIPMENT DRAWINGS & SPECS. FOR
EQUIPMENT ITEMS SHOWN DASHED,
PROVIDED BY EQUIP. CONSULTANT AND/ OR
SUPPLIED BY OWNER. COORDINATE WITH
OTHER TRADES AS NECESSARY.
17. MECH. & ELEC. SYMBOLS AND OUTLETS ARE
SHOWN FOR REFERENCE ONLY. COORDINATE
LOCATIONS WITH MEP DRAWINGS. CONSULT
ARCHITECT FOR CLARIFICATION, IF
NECESSARY.
GENERAL NOTES
INTERIOR ELEVS
MILLWORK:
TYPE
DEPTHWIDTH
KL KEY LOCK, RE: TYPICAL CASEWORK
DETAILS
TL TOT LOCK, RE: TYPICAL CASEWORK
DETAILS
LL LOCKER LOCK, RE: TYPICAL
CASEWORK DETAILS
OPEN TO BEYOND
3'
-
0
"
4' - 11"5' - 0"4' - 11"
2'
-
6
"
PL134
PL134
PL82
PL2
PL2
RBC39
PL2
PL2
A822
10
3' - 8"5' - 2"3' - 8"
1'
-
1
0
1
/
2
"
A822
10
SIM
RBC39
PL82
6
A821
SIM6
A821
SIM 7
A821
SIM7
A821
SIM
PT21
RBC39
EQ EQ
PT82
3
3
/
4
"
4
1
/
2
"
1'
-
5
3
/
4
"
2 21
2'
-
6
"
3"PER OWNER 3"
RP6
BEYOND
OPEN TO BEYOND
4' - 11"
CLEAR
5' - 0"4' - 11"
6"
2'
-
6
"
3'
-
0
"
EQ EQ EQ EQ EQ
REMOVABLE PANEL, TYP.
PRT2PRT2
PL134
PT21
PL2
RBC39
PL134
PL134 PL2
PT21
6
A821
SIM6
A821
SIM 7
A821
SIM
PT21
PL2 PL2
3
1
/
2
"
3
1
/
2
"
2' - 0"2' - 0"
11
A821 11
A821
OPEN TO BEYOND
2'
-
6
"
1"
1'
-
1
0
1
/
2
"
1"
1"4' - 4"1"
PL134
PT28
PL2
PL82
RBC39
7
A821
SIM
PT28
OPEN TO BEYONDOPEN TO BEYOND
REMOVABLE PANEL, TYP.
EQEQEQ
2'
-
6
"
PRT3 PL134
PT21
RBC39
PT21
PT21
7
A821
SIM
PT21
RP6
3
3'
-
0
"
OPEN TO BEYOND
1'
-
1
0
1
/
2
"
A822
10
SIM
6
A821
SIM
5' - 9 3/4"
PL134
PL2
PL82
PL2
RBC39
7
A821
SIM
2'
-
6
"
2'
-
4
"
2'
-
4
"
16"D
E1
35"W 16"D
E1
35"W 16"D
E1
35"W
PRT2
PT21
PL134
PT21
RBC39
9
A821
SIM.
PL82
TYP.
2'
-
4
"
2'
-
4
"
2'
-
6
"
16"D
E1
32"W 16"D
E1
32"W 16"D
E1
32"W
PT21
PL134
RBC39
PT21
9
A821
SIM.
PL82
TYP.16"D
E1
32"W
2'
-
4
"
2'
-
4
"
2'
-
6
"
16"D
E1
33"W 16"D
E1
33"W
KL KL KL KL
9
A821
SIM.
PT21
RBC39
PT21
PT21
PL82
TYP.
PL134
2'
-
6
"
6"
2'
-
6
"
3'
-
0
"
OPEN TO BEYOND
REMOVABLE
PANEL, TYP.
PT21
PL134PL134PL2
RBC39
6
A821
SIM 7
A821
SIM
PT21
24"D
A1
27"W 24"D
A1
27"W
2'
-
1
0
"
CLEARANCE W/ OWNER
COORD. REQ. FURNITURE
TL TL TL TL
TL TL TL TL
PT21
RBC39
PL82
TYP.
PL134
24"D
A1
21"W24"D
A4
21"W
ADA PANEL
C2
33"W 24"D
2'
-
0
"
2'
-
1
0
"
PT21
PL134
PL134
PL82
RBC39
PL82
TYP.
PT2
SD1
ADA PANEL
C2
33"W 24"D 24"D
A1
30"W24"D
A4
15"W
2'
-
0
"
2'
-
1
0
"
TL
TL TL
TL TL
PT28
PL134PL134
PL82
RBC39
PL82
TYP.
PT28
PT2
SD1
24"D
A4
15"W24"D
A1
30"W
2'
-
1
0
"
2'
-
0
"
2'
-
6
"
TLTL
TLTL
TL
GD1 SH1
DH1
SC2
PT21
PL134
PL134
PL82
RBC39
TYP.
R 0' - 6 "
1' - 6"
PL134
IRL6
9
A821
SIM.
2'
-
6
"
9
A821
SIM.
PT21
PL134
RBC39
ADA PANEL
C2
33"W 24"D24"D
A1
15"W 24"D
A1
18"W 24"D
A1
33"W 24"D
A1
33"W
16"D
E1
30"W 16"D
E1
30"W 16"D
E1
30"W 16"D
E1
30"W 16"D
E1
30"W
REF1
CM1 MCW1
2'
-
4
"
2'
-
0
"
2'
-
1
0
"
UCF1
TEL1
PT21
RBC39
PT21
PL134
PL134PL82
PL82
TYP.
TYP.
CLEAR
2' - 0"
PT2
HS1
PL82
END PANEL
4"
3'
-
5
"
3'
-
5
"
TYP.
1' - 0"PT21
RBC39
PT21 8
A821
7"
7"
3"
3"
LL
LL
LL
LL
LL
LL
LL
LL
LL
LL
LL
LL
LL
LL
4
TYP.
2'
-
1
0
"
24"D
A1
27"W 24"D
A1
27"W 24"D
A1
27"W
SC1
CLEARANCE W/ OWNER
COORD. REQ. FURNITURE
PT21
PL134PL82
TYP.
RBC39
TL TL
TL TL
TL TL
TL TL
TL TL
TL TL
OFOI BANNER SIGNAGE. VERIFY SIZE WITH
OWNER.
1
ALIGN HEIGHT OF STENCIL DETAIL WITH STENCIL
DETAIL ON ADJACENT WALLS. RE: FINISH DETAILS.
2
NOTES BY NUMBER
INTERIOR ELEVATIONS
CASEWORK PRINTER CART.3
LOCKER NUMBER.4
SHEET NUMBER
4040 N CENTRAL EXPY,
SUITE 720
DALLAS, TEXAS 75204
t 314.302.6864
www.modusarchitecture.com
FOR INFORMATION
PURPOSES ONLY. NOT TO
BE USED IN ANY CAPACITY
FOR BIDDING, PERMITTING,
OR CONSTRUCTION
REVISIONS:
SHEET NAME
ISSUE DATE:
16
2
5
L
A
N
C
A
S
T
E
R
D
R
I
V
E
GR
A
P
E
V
I
N
E
,
T
E
X
A
S
7
6
0
5
1
A711
INTERIOR
ELEVATIONS
PE
R
M
I
T
S
E
T
CO
O
K
C
H
I
L
D
R
E
N
'
S
12/19/2024
1/2" = 1'-0"1 INTERIOR ELEVATION - CHECK IN - FRONT
1/2" = 1'-0"2 INTERIOR ELEVATION - CHECK IN - BACK
1/2" = 1'-0"3 INTERIOR ELEVATION - CHECK OUT1/2" = 1'-0"4 INTERIOR ELEVATION - CHECK OUT
1/2" = 1'-0"6 INTERIOR ELEVATION - RECEPTION
1/2" = 1'-0"14 INTERIOR ELEVATION - WORK ROOM
1/2" = 1'-0"13 INTERIOR ELEVATION - WORK ROOM
1/2" = 1'-0"5 INTERIOR ELEVATION - WORK STATION
1/2" = 1'-0"7 INTERIOR ELEVATION - CHECK OUT
1/2" = 1'-0"8 INTERIOR ELEVATION - VITALS
1/2" = 1'-0"10 INTERIOR ELEVATION - NURSING
1/2" = 1'-0"9 INTERIOR ELEVATION - CORRIDOR
1/2" = 1'-0"11 INTERIOR ELEVATION - TYP. EXAM ROOM
1/2" = 1'-0"12 INTERIOR ELEVATION - WORK ROOM
1/2" = 1'-0"15 INTERIOR ELEVATION - BREAK ROOM
1/2" = 1'-0"16 INTERIOR ELEVATION - BREAK ROOM
1/2" = 1'-0"17 INTERIOR ELEVATION - VITALS
OPEN TO BEYOND
3'
-
0
"
2' - 10 1/2"2' - 10 1/2"2' - 10 1/2"2' - 10 1/2"2' - 10 1/2"2' - 10 1/2"2' - 10 1/2"2' - 10 1/2"
A822
10
SIM
TYP.
1'
-
1
0
1
/
2
"
3'
-
0
"
1'
-
1
0
1
/
2
"
CLEAR
5' - 0"
6
A821
SIM6
A821
SIM
PT28
PL134PL134
RBC39RBC39
OPEN TO BEYOND
3'
-
0
"
2' - 9 1/8"2' - 9 1/8"
1'
-
1
0
1
/
2
"
PT28
PL134
RBC39
A822
10
SIM6
A821
SIM
OPEN TO BEYOND
3'
-
0
"
2' - 9 1/8"2' - 9 1/4"
1'
-
1
0
1
/
2
"
A822
10
SIM
TYP.
PT28
PL134
RBC39
6
A821
SIM
3'
-
0
"
1'
-
1
0
"
2'
-
4
"
16"D
E1
30"W 16"D
E1
30"W 16"D
E1
30"W
24"D
A1
30"W 24"D
A1
30"W 24"D
A1
30"W
2'
-
4
"
1'
-
1
0
"
3'
-
0
"
24"D
A1
30"W
2'
-
6
"
PRT2 PRT2
24"D
A1
30"W24"D
A1
30"W
16"D
E1
30"W16"D
E1
30"W16"D
E1
30"W16"D
E1
30"W16"D
E1
30"W16"D
E1
30"W16"D
E1
30"W16"D
E1
30"W16"D
E1
30"W
PRT3
PL134 PL82
TYP.
PL82
TYP.
PL82
TYP.
PL82
TYP.
PL82
TYP.
PL82
TYP.
PL134PL134PL134
PL134PL82
TYP.
RBC39 RBC39 RBC39RBC39RBC39
PT28 PT28 PT28
PT28 PT28
PT28 PT28PT28
9
A821
SIM.9
A821
SIM.9
A821
SIM.
RBC39
PT28
PT28 PT28 PT28 PT28 PT28
2'
-
6
"
2'
-
6
"
OPEN TO BEYOND
EQ EQ EQ EQ EQ EQ EQ EQ
3'
-
0
"
REMOVABLE PANEL, TYP.
PT28
PL134
RBC39RBC39
REMOVABLE PANEL, TYP.
6
A821
SIM 6
A821
SIM
PL2PL2PL134
PT28 PT28
PT28
RBC39
PT28
RBC39
2'
-
6
"
6"
MFZ1
MRF1
3'
-
0
"
1'
-
1
0
"
2'
-
4
"
1'
-
1
0
"
3'
-
0
"
C2
33"W 24"D24"D
A4
15"W24"D
A1
33"W24"D
A1
30"W24"D
A1
30"W24"D
A1
30"W24"D
A1
30"W
VERIFY WITH EQ. CLEARANCE
5' - 1"24"D
A1
15"W24"D
A4
30"W 24"D
A1
30"W 24"D
A1
30"W 24"D
A1
30"W
16"D
E1
30"W 16"D
E1
30"W 16"D
E1
30"W 16"D
E1
30"W 16"D
E1
30"W 16"D
E1
30"W 16"D
E1
30"W 16"D
E1
30"W
KL KL KL KL
VC1 VC1
PRT3
LB1 LB1 LB1 LB1
PL134PL82
TYP.
RBC39
PL134
PT28
PL134
PT28
PL134
PL82
TYP.
PL82
RBC39
PL82
TYP.
PT2
ALZ1
R
0' - 6
"R 0' - 6 "SD1
OPEN TO BEYOND
EQEQ
REMOVABLE PANEL, TYP.
3'
-
0
"
PT28
PL134
RBC39
PT28
PL2
PT28
6
A821
SIM
2'
-
6
"
6"
3'
-
0
"
2'
-
0
"
ADA PANEL
C2
33"W 24"D24"D
A1
36"W 24"D
A4
15"W
TL TL
TL
TL TL
PL134
PT28
PL134
PL82
PT28
PL82
RBC39
PT2
SD1
24"D
A1
30"W 24"D
A1
30"W 24"D
A1
30"W 24"D
A1
30"W 24"D
A1
30"W 24"D
A1
30"W 24"D
A1
30"W 24"D
A4
27"W 24"D
A1
33"W 24"D
A1
33"W
C2
33"W 24"D
3'
-
0
"
LRF13'
-
0
"
1'
-
1
0
"
2'
-
4
"
16"D
E1
30"W 16"D
E1
30"W 16"D
E1
30"W 16"D
E1
30"W 16"D
E1
30"W 16"D
E1
30"W 16"D
E1
30"W
TBD BY OWNER
PL134
TYP.
RBC39
PL134
PL82
TYP.
8"
PL82
CLEAR
2' - 3"
PT28
PT28
PL82
TYP.
PL82
PT2
SD1
PC1PC1
PL82
VALENCE
2"
12" DEPTH9
A821
SIM.
PL134
ADA PANEL
27"D
A9
51"W
2'
-
0
"
3'
-
0
"
7'
-
2
"
C2
33"W 24"D24"D
A4
15"W
TL
KLKL
PL134
PT28
PT28
PT28
RBC39 RBC39
PL134
PL82
PL82
PL82
KLKL
PT2
SD1
PT28
1. RE: SHEET G001 FOR ADDITIONAL GENERAL
NOTES THAT ARE APPLICABLE.
2. RE: SHEET G003/4 ACCESSIBILITY STANDARDS
FOR MOUNTING HEIGHTS OF FIXTURES AND
ACCESSORIES.
3. RE: FINISH LEGEND AND FINISH SCHEDULE
FOR SPECIFIC FINISH INFORMATION AND
LOCATIONS.
4. WALL FINISHES SHOWN ARE FOR ACCENT
CLARIFICATION ONLY. RE: FINISH FLOOR PLAN
AND FINISH LEGEND FOR ADDITIONAL ROOM
FINISHES.
5. PROVIDE GYPSUM BOARD CONTROL JOINTS
AT DOOR HEADERS WHERE GYPSUM BOARD
EXCEEDS 30 FEET (TYP.), UNLESS SHOWN
OTHERWISE. JOINTS TO BE LINED UP WITH
BOTH SIDES OF DOOR FRAMES FOR DOORS
4'-0" AND OVER AND ALL DOORS THAT ARE
LEAD LINED.
6. ALIGN ALL WALL TILE JOINTS WITH FLOOR
TILE JOINTS, UNLESS NOTED OR SHOWN
OTHERWISE.
7. TRANSITION ALL WALL AND BASE FINISHES,
AND/ OR COLOR CHANGES AT INSIDE
CORNERS, UNLESS NOTED OTHERWISE.
CONSULT ARCHITECT FOR CLARIFICATION, IF
NECESSARY.
8. CONTINUE WALL FINISH AS SCHEDULED
BEHIND ALL FURNITURE AND EQUIPMENT,
INCLUDING UNDER OPEN COUNTERS.
9. CONTINUE WALL BASE AT ALL WALLS,
FURRED OUT COLUMNS & COLUMN COVERS,
AND AT ALL CASEWORK TOE KICKS, SIDE
PANELS, AND UNDER OPEN COUNTERS,
UNLESS NOTED OTHERWISE.
10. CONTRACTOR SHALL FIELD VERIFY ALL
DIMENSIONS PRIOR TO MILLWORK/
CASEWORK FABRICATION & INSTALLATION.
11. ALL MILLWORK/CASEWORK CONSTRUCTION
SHALL MEET AWI PREMIUM STANDARDS,
UNLESS NOTED OR SPECIFIED OTHERWISE.
12. CONTRACTOR SHALL PROVIDE & INSTALL
GROMMETS AT 48” O.C. MAX. AT ALL WORK
STATIONS WITH OPEN KNEE SPACE.
COORDINATE LOCATIONS DIRECTLY WITH
ELECTRICAL/DATA DRAWINGS FOR OUTLET
LOCATIONS. COLOR TO BE SELECTED BY
ARCHITECT.
13. CONTRACTOR SHALL PROVIDE CONCEALED
COUNTERTOP BRACKETS AT OPEN KNEE
SPACES WIDER THAN 42” (TYP.). CENTER IN
OPEN AREA AND PAINT TO MATCH WALL
COLOR, UNLESS NOTED OR SHOWN
OTHERWISE.
14. ALL EXPOSED CASEWORK/MILLWORK
SURFACES SHALL BE FINISHED TO MATCH
ADJACENT PLASTIC LAMINATE SURFACES,
UNLESS NOTED OTHERWISE.
15. ALL FILLER PANELS SHALL BE FINISHES TO
MATCH ADJACENT SURFACES AND SCRIBED
TO FIT ADJACENT WALL, UNLESS NOTED
OTHERWISE.
16. RE: EQUIPMENT DRAWINGS & SPECS. FOR
EQUIPMENT ITEMS SHOWN DASHED,
PROVIDED BY EQUIP. CONSULTANT AND/ OR
SUPPLIED BY OWNER. COORDINATE WITH
OTHER TRADES AS NECESSARY.
17. MECH. & ELEC. SYMBOLS AND OUTLETS ARE
SHOWN FOR REFERENCE ONLY. COORDINATE
LOCATIONS WITH MEP DRAWINGS. CONSULT
ARCHITECT FOR CLARIFICATION, IF
NECESSARY.
GENERAL NOTES
INTERIOR ELEVS
OPEN TO BEYOND
PL134
RBC39
PROVIDE PL82 FINISHED
SIDE PANELS WITH SIM.
4" TOE KICK.
PL82 3'
-
0
"
10
A821
SIM
MILLWORK:
TYPE
DEPTHWIDTH
KL KEY LOCK, RE: TYPICAL CASEWORK
DETAILS
TL TOT LOCK, RE: TYPICAL CASEWORK
DETAILS
LL LOCKER LOCK, RE: TYPICAL
CASEWORK DETAILS
OFOI BANNER SIGNAGE. VERIFY SIZE WITH
OWNER.
1
ALIGN HEIGHT OF STENCIL DETAIL WITH STENCIL
DETAIL ON ADJACENT WALLS. RE: FINISH DETAILS.
2
NOTES BY NUMBER
INTERIOR ELEVATIONS
CASEWORK PRINTER CART.3
LOCKER NUMBER.4
SHEET NUMBER
4040 N CENTRAL EXPY,
SUITE 720
DALLAS, TEXAS 75204
t 314.302.6864
www.modusarchitecture.com
FOR INFORMATION
PURPOSES ONLY. NOT TO
BE USED IN ANY CAPACITY
FOR BIDDING, PERMITTING,
OR CONSTRUCTION
REVISIONS:
SHEET NAME
ISSUE DATE:
16
2
5
L
A
N
C
A
S
T
E
R
D
R
I
V
E
GR
A
P
E
V
I
N
E
,
T
E
X
A
S
7
6
0
5
1
A712
INTERIOR
ELEVATIONS
PE
R
M
I
T
S
E
T
CO
O
K
C
H
I
L
D
R
E
N
'
S
12/19/2024
1/2" = 1'-0"1 INTERIOR ELEVATION - MA STATION
1/2" = 1'-0"5 INTERIOR ELEVATION - MA STATION
1/2" = 1'-0"2 INTERIOR ELEVATION - MA STATION
1/2" = 1'-0"6 INTERIOR ELEVATION - MA STATION
1/2" = 1'-0"4 INTERIOR ELEVATION - MA STATION
1/2" = 1'-0"8 INTERIOR ELEVATION - MED LAB
1/2" = 1'-0"3 INTERIOR ELEVATION - MA STATION
1/2" = 1'-0"11 INTERIOR ELEVATION - CORRIDOR HANDWASH
1/2" = 1'-0"10 INTERIOR ELEVATION - MED LAB
1/2" = 1'-0"9 INTERIOR ELEVATION - CORRIDOR HANDWASH
1/2" = 1'-0"7 INTERIOR ELEVATION - MA STATION
1"1"
2' - 4"
4"
3/4"
10"
RE
:
I
N
T
.
E
L
E
V
A
T
I
O
N
S
ACCESS PANEL -P-LAM ON
3/4" MDF
A&M CONCEALED FLAT BRACKET
OR CUSTOM EQUIVALENT
FIELD-DRILL GROMMETS AS REQ.
BASE AS SCHED
WIRINGRE
:
I
N
T
.
E
L
E
V
A
T
I
O
N
S
1 3/4"
1
1
/
2
"
7'
-2"
U
.
N
.
O
.
BACK PANEL
ADJUSTABLE SHELF, TYP.
MOUNTING RAIL
5/
8
"
1/2" PLASTIC LAMINATE
CLAD SCRIBE
INT. ELEVATIONS
14" TO FACE OF
CABINET UNO ON
RE
:
E
L
E
V
A
T
I
O
N
S
.
PULL-1, RE: MILLWORK
HARDWARE SCHEDULE
2
1
/
4
"
U.C. LIGHT, RE: ELECTRICAL
BOX DRAWER
LAMINATE COUNTERTOP, PER INT.
ELEVATIONS
BACKSPLASH, PER INT. ELEVATIONS
BACK PANEL
PULL-1, RE: MILLWORK HARDWARE
SCHEDULE
ADJUSTABLE SHELF
CLAD DOOR/DRAWERS, FINISH PER INT.
ELEVATIONS
MOUNTING RAIL
WOOD BLOCKING
ON INT. ELEVATIONS
25" U.N.O.
6"
1
1
/
2
"
3/4"
RE
:
E
L
E
V
A
T
I
O
N
S
A821
13
A821
12
BASE AS SCHED.
4"
3/4"1"
1"
2' - 8"
RE
:
I
N
T
.
E
L
E
V
A
T
I
O
N
S
1
1
/
2
"
TRANSACTION TOP BEYOND
FIELD-DRILL GROMMETS AS REQ.
A&M CONCEALED FLAT BRACKET
OR CUSTOM EQUIVALENT
1
1
/
2
"
RE
:
E
L
E
V
A
T
I
O
N
S
A821
13
A821
12
6'' DIA. SS TRASH GROMMET,
BOD: MOCKETT TM1B
TRASH RECEPTACLE, OFOI
ON INT. ELEVATIONS
25" U.N.O.
LAMINATE COUNTERTOP, PER INT.
ELEVATIONS
BACKSPLASH, PER INT. ELEVATIONS
BACK PANEL
CLAD DOOR/DRAWERS, FINISH PER INT.
ELEVATIONS
MOUNTING RAIL
WOOD BLOCKING
9"
7"
1'
-
6
"
2'
-
1
0
"
T
O
S
I
N
K
R
I
M
3/4" LIP
9"
6
1 MIN
SLOPE
6"
M
A
X
BULL NOSE AT END OF
PANEL
OF DRAIN
11"
PLASTIC LAMINATE CLAD,
REMOVABLE PANEL WITHOUT
EXPOSED FASTENERS
PLACE DRAIN TOWARD BACK
OF SINK
INTERMEDIATE STL ANGLE
SUPPORT AT 36" MAX OC AND
30" MIN OC
6" MAX TO BOTTOM OF SINK
BOWL
CONTINUOUS WOOD LEDGER
(BACK AND ENDS)
PLAM COUNTERTOP
SPLASHES AT ABUTTING
SIDEWALLS, RE: INT. ELEVATIONS
INTERIOR ELEVATIONS
2' - 1" UNO ON
MAX
6"
BOWL WIDTH
1' - 1 1/2" MAX
4'-0" CLEAR
FLOOR SPACE
PE
R
I
N
T
.
E
L
E
V
A
T
I
O
N
S
FACE OF CABINET
ADJUSTABLE
SHELF, TYP. U.N.O.
FIXED SHELF
MOUNTING RAIL
WOOD BLOCKING
1/2" PLASTIC LAMINATE
CLAD SCRIBE
BASE AS SCHED.
PE
R
I
N
T
.
E
L
E
V
A
T
I
O
N
1"
4"
PULL-1, RE: MILLWORK
HARDWARE SCHEDULE
PULL-1, RE: MILLWORK
HARDWARE SCHEDULE
PER INT. ELEVATION
A&M CONCEALED FLAT
BRACKET OR CUSTOM
EQUIVALENT
RE
:
I
N
T
E
R
I
O
R
E
L
E
V
A
T
I
O
N
S
1
1
/
2
"
U.N.O.
2' - 1"
CABINET DOOR
BASE AS SCHED.
FACE OF CABINET
3/4" WIDE MIN.
WATERPROOF MDF
3 1/4"
4
1
/
8
"
1/
8
"
FACE OF CABINET
PLASTIC
LAMINATE EDGE
ON 2 LAYERS OF
3/4" SUBSTRATE
1
1
/
2
"
1"
3/
4
"
3/4"PLASTIC
LAMINATE FINISH
AT KNEE SPACE
CONDITIONS
DRAWER/
DOOR PULL
NOTE: REFER TO FINISH LEGEND FOR COUNTERTOP MATERIAL
VARIES
RE
:
I
N
T
E
R
I
O
R
E
L
E
V
A
T
I
O
N
1"
4"
1' - 3"3"
MOUNTING
RAIL
WOOD
BLOCKING
BASE AS SCHED.
1/2" PLASTIC LAMINATE CLAD SCRIBE
DOUBLE COAT HOOK ON BOTH INTERIOR
FACING SIDES OF LOCKER, TYP.
LOCKER LOCK, RE: TYPICAL CASEWORK
DETAILS
LOCKER LOCK, RE: TYPICAL CASEWORK
DETAILS
DOUBLE COAT HOOK ON BOTH SIDES, TYP.
TY
P
.
7"
3'
-
8
"
M
A
X
.
ADJUSTABLE SHELF
ADJUSTABLE SHELF
GENERAL NOTES
CASEWORK SECTIONS
ALL SECTION DETAILS ON THIS SHEET MAY NOT APPLY
TO THIS PROJECT:
ARCHITECTURAL WOODWORK TARGETING:
TARGETS, WIDTH AND HEIGHT ARE INDICATED ON THE
INTERIOR ELEVATIONS IN THE A45 SERIES
DRAWINGS.
VERIFY AND COORDINATE CLEAR DIMENSIONS
REQUIRED FOR OWNER-FURNISHED EQUIPMENT
LOCATED WITHIN OR ADJACENT TO ANY CABINETS.
COORDINATE INSTALLATION OF SINKS WITH
ASSOCIATED PIPING AND FITTINGS PLUS WITH
INSTALLATION OF ACCESSIBLE COVER PANELS.
REQUIRED SCRIBES AND FILLER PIECES SHALL BE
INSTALLED TO ALLOW PROPER OPERATION OF
DRAWERS AND DOORS. THEY SHALL BE EVENLY
DISTRIBUTED AND OF EQUAL WIDTH ALONG A SINGLE
RUN OF CABINETS. THEY SHALL BE 3" WIDE, MAXIMUM
EXCEPT INSIDE CORNER FILLERS SHALL BE 2 1/2" WIDE,
MINIMUM. RE: TYPICAL CASEWORK DETAILS.
WHERE BASE CABINETS INTERSECT AT INSIDE CORNER
CONDITIONS PROVIDE WALL MOUNTED LEDGERS TO
SUPPORT COUNTERTOP AT CORNERS. WHERE UPPER
CABINETS INTERSECT AT INSIDE CORNER CONDITIONS
PROVIDE HORIZONTAL FILLER PANEL FLUSH WITH
BOTTOM OF CABINETS.
PROVIDE PLASTIC SCREW COVERS TO CONCEAL
SCREW HEADS AT ALL SEMI-EXPOSED CABINET
SURFACES. ALL EXPOSED SCREWS SHALL BE
COUNTERSUNK.
CORE MATERIAL FOR SHELVING GREATER THAN 30"
WIDE SHALL BE 1" THICK.
ALL VERTICAL JOINTS BETWEEN CABINETS SHALL BE
BUTT JOINTS. THEY SHALL LOOK "SEAMLESS" AND
COVERED IN PLASTIC LAMINATE.
FIELD VERIFY DIMENSIONS BEFORE CABINET
FABRICATION. NOTIFY ARCHITECT OF CONFLICTS AND
DISCREPANCIES PRIOR TO FABRICATION.
PROVIDE FILLER PANELS AS NEEDED BETWEEN BUILT-
IN APPLIANCES AND ADJACENT CABINETS OR WALLS.
ALL COUNTERTOPS 25" DEEP UNO ON INTERIOR
ELEVATIONS.
PROVIDE WALL MOUNTED BRACKETS FOR SUPPORT OF
COUNTERTOPS AT KNEE SPACES. COUNTERTOPS
SHALL BE SUPPORTED 30" MINIMUM - 36" MAXIMUM OC.
LOCATE GROMMETS AT BACK OF COUNTERTOPS
(OVER KNEE SPACE, ONLY) EVERY 36" OC WITH A
MINIMUM OF 1 PER KNEE SPACE UNO ON THE
EQUIPMENT PLAN. COORDINATE FINAL GROMMET
LOCATIONS WITH OWNER, EXCEPT DO NOT PROVIDE
GROMMETS AT ACCESSIBLE PORTION OF COUNTER, AS
INDICATED ON THE EQUIPMENT PLANS.
PROVIDE ALL BACK AND SIDE SPLASHES THAT ARE 4"
TALL X 3/4" THICK IF PLASTIC LAMINATE, 1/2" THICK IF
SOLID SURFACE MATERIAL, UNO ON THE INTERIOR
ELEVATIONS. ALL SPLASHES SHALL BE SCRIBED TO
CONFORM TO THE SURFACE OF ABUTTING WALLS. ALL
SPLASHES SHALL BE SEALED TO THE WALL WITH
CLEAR SILICONE SEALANT. PROVIDE SPLASHES ON ALL
REAR AND SIDE WALLS AT BASE CABINETS.
PROVIDE SCHEDULED BASE ALONG BOTTOM OF
EXPOSED FRONTS, BACKS, SIDES, AND ENDS OF ALL
FIXED CABINETS, PEDESTALS, VERTICAL SUPPORT
PANELS, KNEE SPACES,ETC, UNO ON THE INTERIOR
ELEVATIONS.
ALL DRAWER LENGTHS SHALL BE 20", UNO.
ALL DRAWERS GREATER THAN 30" WIDE SHALL HAVE 2
PULLS.
ALL HORIZONTAL AND VERTICAL JOINTS SHALL BE 1/8"
MAX.
ALL TOE KICK SPACES SHALL BE 4 1/8" TALL X 3 1/4"
DEEP.
TOP OF UPPER AND FULL HEIGHT CABINETS SHALL BE
7'-2" AFF UNO ON INTERIOR ELEVATIONS.
RE: REFLECTED CEILING PLAN FOR FURR DOWN
LOCATIONS.
WALL MOUNTED UPPER CABINETS SHALL INCLUDE
ADJUSTABLE SHELF (SHELVES), UNO
CABINET HEIGHT NUMBER OF SHELVES
THROUGH 24" 1
25" THROUGH 42" 2
43" THROUGH 48" 3
TOPS AND BOTTOMS OF WALL HUNG CABINETS SHALL
BE 3/4" THICK WITH PLASTIC LAMINATE ON EXPOSED
SURFACES.
BACKS OF WALL HUNG CABINETS SHALL BE 1/4" THICK
UNO.
BACKS OF BASE CABINETS SHALL BE 1/4" THICK UNO.
.
24"
A1
CABINET WIDTH
CABINET TYPE
GENERAL:
1.
2.
3.
4.
5.
6.
7.
8.
9.
10.
11.
COUNTERTOP:
1.
2.
3.
4.
BASE CABINETS:
1.
2.
3.
4.
5.
UPPER CABINETS
1.
2.
3.
4.
5.
6.
ZORO G5570201 2"
SWIVEL CASTOR, TYP.
1' - 6"
3/
4
"
2
3
/
4
"
4"
A&M CONCEALED
FLAT BRACKET OR
CUSTOM EQUIVALENT
BASE AS SCHED
1
1
/
2
"
1' - 4"
1"1"
SIDE PANEL BEYOND
RE
:
I
N
T
E
R
I
O
R
E
L
E
V
A
T
I
O
N
S
SHEET NUMBER
4040 N CENTRAL EXPY,
SUITE 720
DALLAS, TEXAS 75204
t 314.302.6864
www.modusarchitecture.com
FOR INFORMATION
PURPOSES ONLY. NOT TO
BE USED IN ANY CAPACITY
FOR BIDDING, PERMITTING,
OR CONSTRUCTION
REVISIONS:
SHEET NAME
ISSUE DATE:
16
2
5
L
A
N
C
A
S
T
E
R
D
R
I
V
E
GR
A
P
E
V
I
N
E
,
T
E
X
A
S
7
6
0
5
1
A821
TYPICAL
CASEWORK
SECTIONS
PE
R
M
I
T
S
E
T
CO
O
K
C
H
I
L
D
R
E
N
'
S
12/19/2024
1" = 1'-0"6 CASEWORK SECTION - TRANSACTION TOP
1" = 1'-0"5 TYPE E1 - UPPER CABINET
1" = 1'-0"1 TYPE A1 - BASE CABINET
1" = 1'-0"7 CASEWORK SECTION - ACCESSIBLE
1" = 1'-0"2 TYPE A4 - BASE CABINET
1" = 1'-0"4 TYPE C2 - ACCESSIBLE SINK
1 1/2" = 1'-0"3 CASEWORK SECTION - TYPE A9
1" = 1'-0"9 CASEWORK SECTION - WRITING SURFACE
3" = 1'-0"12 SECTION DETAIL - TOE KICK
3" = 1'-0"13 SECTION DETAIL - PLASTIC LAMINATE
1 1/2" = 1'-0"8 CASEWORK SECTION - LOCKERS
3" = 1'-0"11 CASEWORK SECTION - MOBILE PEDESTAL
1" = 1'-0"10 CASEWORK SECTION - TEAMWORK ISLAND
PASS THRU
48
"
M
A
X
.
A
F
F
FR BLOCKING AS
REQUIRED
PE
R
.
M
A
N
U
F
A
C
T
U
R
E
R
2"
2"2"
1
3
/
8
"
1
3
/
8
"
1
3
/
8
"
2"
1
3
/
8
"
2"
3
5
/
8
"
2"
1
3
/
8
"
MAGNETIC LOCK AT DRAWERS MAGNETIC LOCK AT CABINET DOORS
1"
1
"
1"
1
"
OUTLINE OF
CASEWORK BELOW
OUTLINE OF
CASEWORK BELOW
LEAVE CORNER SQUARE
NEXT TO EQUIPMENT
R2 CORNER AT EXPOSED
FINISHED ENDS
WALL
TITE-JOINT
FASTENER BELOW
BISCUIT
COUNTERTOP SEAM
FINISHED EDGE
1
/
8
"
7
/
8
"
1/16" 1/8"
7
/
8
"
3/4" 3/4"
CA
B
S
I
D
E
CA
B
S
I
D
E
DOORDOOR
TYPICAL CABINET SEAM
DOOR
CA
B
S
I
D
E
DO
O
R
CAB TOP
7/8"
1/8"
RE
:
E
L
E
V
1
1
/
2
"
T
Y
P
.
1
/
8
"
3/
4
"
1"
GYP. SOFFIT
DOOR
CA
B
S
I
D
E
7/
8
"
1
/
8
"
RE: ELEV
1 1/2" TYP.
1/8"
3/4"
SU
B
T
R
I
M
FACE OF
ADJACENT
WALL
DO
O
R
CAB SIDE
3
/
4
"
1/
8
"
1/8"
2
1
/
8
"
DOOR
DO
O
R
SCRIBE
CA
B
S
I
D
E
SU
B
T
R
I
M
SC
R
I
B
E
SUB TRIM
CAB SIDE
3
/
4
"
3/
4
"
7/8"
1/8"
MI
N
.
2
1
/
2
"
1/
8
"
1/8"MIN.
3 1/4"
7/
8
"
1/
8
"
3/4" 3/4"
BOTTOM BEYOND
ON UPPER CABINETS ONLY
OPEN TO FLOOR ON
TALL CABINETS AND
BASE CABINETS
1"5"1"RE: INTERIOR ELEVATIONS 1"5"1"
1
1
/
2
"
1"
5"
1"
RE
:
I
N
T
E
R
I
O
R
E
L
E
V
A
T
I
O
N
S
1"
4"
PL134
PL82
PL82
PL82PL82
PL120 PL120
1"1"
RBC39
PL2
1 1/2"1 1/2"
GENERAL NOTES
CASEWORK SECTIONS
ALL SECTION DETAILS ON THIS SHEET MAY NOT APPLY
TO THIS PROJECT:
ARCHITECTURAL WOODWORK TARGETING:
TARGETS, WIDTH AND HEIGHT ARE INDICATED ON THE
INTERIOR ELEVATIONS IN THE A45 SERIES
DRAWINGS.
VERIFY AND COORDINATE CLEAR DIMENSIONS
REQUIRED FOR OWNER-FURNISHED EQUIPMENT
LOCATED WITHIN OR ADJACENT TO ANY CABINETS.
COORDINATE INSTALLATION OF SINKS WITH
ASSOCIATED PIPING AND FITTINGS PLUS WITH
INSTALLATION OF ACCESSIBLE COVER PANELS.
REQUIRED SCRIBES AND FILLER PIECES SHALL BE
INSTALLED TO ALLOW PROPER OPERATION OF
DRAWERS AND DOORS. THEY SHALL BE EVENLY
DISTRIBUTED AND OF EQUAL WIDTH ALONG A SINGLE
RUN OF CABINETS. THEY SHALL BE 3" WIDE, MAXIMUM
EXCEPT INSIDE CORNER FILLERS SHALL BE 2 1/2" WIDE,
MINIMUM. RE: TYPICAL CASEWORK DETAILS.
WHERE BASE CABINETS INTERSECT AT INSIDE CORNER
CONDITIONS PROVIDE WALL MOUNTED LEDGERS TO
SUPPORT COUNTERTOP AT CORNERS. WHERE UPPER
CABINETS INTERSECT AT INSIDE CORNER CONDITIONS
PROVIDE HORIZONTAL FILLER PANEL FLUSH WITH
BOTTOM OF CABINETS.
PROVIDE PLASTIC SCREW COVERS TO CONCEAL
SCREW HEADS AT ALL SEMI-EXPOSED CABINET
SURFACES. ALL EXPOSED SCREWS SHALL BE
COUNTERSUNK.
CORE MATERIAL FOR SHELVING GREATER THAN 30"
WIDE SHALL BE 1" THICK.
ALL VERTICAL JOINTS BETWEEN CABINETS SHALL BE
BUTT JOINTS. THEY SHALL LOOK "SEAMLESS" AND
COVERED IN PLASTIC LAMINATE.
FIELD VERIFY DIMENSIONS BEFORE CABINET
FABRICATION. NOTIFY ARCHITECT OF CONFLICTS AND
DISCREPANCIES PRIOR TO FABRICATION.
PROVIDE FILLER PANELS AS NEEDED BETWEEN BUILT-
IN APPLIANCES AND ADJACENT CABINETS OR WALLS.
ALL COUNTERTOPS 25" DEEP UNO ON INTERIOR
ELEVATIONS.
PROVIDE WALL MOUNTED BRACKETS FOR SUPPORT OF
COUNTERTOPS AT KNEE SPACES. COUNTERTOPS
SHALL BE SUPPORTED 30" MINIMUM - 36" MAXIMUM OC.
LOCATE GROMMETS AT BACK OF COUNTERTOPS
(OVER KNEE SPACE, ONLY) EVERY 36" OC WITH A
MINIMUM OF 1 PER KNEE SPACE UNO ON THE
EQUIPMENT PLAN. COORDINATE FINAL GROMMET
LOCATIONS WITH OWNER, EXCEPT DO NOT PROVIDE
GROMMETS AT ACCESSIBLE PORTION OF COUNTER, AS
INDICATED ON THE EQUIPMENT PLANS.
PROVIDE ALL BACK AND SIDE SPLASHES THAT ARE 4"
TALL X 3/4" THICK IF PLASTIC LAMINATE, 1/2" THICK IF
SOLID SURFACE MATERIAL, UNO ON THE INTERIOR
ELEVATIONS. ALL SPLASHES SHALL BE SCRIBED TO
CONFORM TO THE SURFACE OF ABUTTING WALLS. ALL
SPLASHES SHALL BE SEALED TO THE WALL WITH
CLEAR SILICONE SEALANT. PROVIDE SPLASHES ON ALL
REAR AND SIDE WALLS AT BASE CABINETS.
PROVIDE SCHEDULED BASE ALONG BOTTOM OF
EXPOSED FRONTS, BACKS, SIDES, AND ENDS OF ALL
FIXED CABINETS, PEDESTALS, VERTICAL SUPPORT
PANELS, KNEE SPACES,ETC, UNO ON THE INTERIOR
ELEVATIONS.
ALL DRAWER LENGTHS SHALL BE 20", UNO.
ALL DRAWERS GREATER THAN 30" WIDE SHALL HAVE 2
PULLS.
ALL HORIZONTAL AND VERTICAL JOINTS SHALL BE 1/8"
MAX.
ALL TOE KICK SPACES SHALL BE 4 1/8" TALL X 3 1/4"
DEEP.
TOP OF UPPER AND FULL HEIGHT CABINETS SHALL BE
7'-2" AFF UNO ON INTERIOR ELEVATIONS.
RE: REFLECTED CEILING PLAN FOR FURR DOWN
LOCATIONS.
WALL MOUNTED UPPER CABINETS SHALL INCLUDE
ADJUSTABLE SHELF (SHELVES), UNO
CABINET HEIGHT NUMBER OF SHELVES
THROUGH 24" 1
25" THROUGH 42" 2
43" THROUGH 48" 3
TOPS AND BOTTOMS OF WALL HUNG CABINETS SHALL
BE 3/4" THICK WITH PLASTIC LAMINATE ON EXPOSED
SURFACES.
BACKS OF WALL HUNG CABINETS SHALL BE 1/4" THICK
UNO.
BACKS OF BASE CABINETS SHALL BE 1/4" THICK UNO.
.
24"
A1
CABINET WIDTH
CABINET TYPE
GENERAL:
1.
2.
3.
4.
5.
6.
7.
8.
9.
10.
11.
COUNTERTOP:
1.
2.
3.
4.
BASE CABINETS:
1.
2.
3.
4.
5.
UPPER CABINETS
1.
2.
3.
4.
5.
6.
1" = 1'-0"1 SECTION DETAIL - PASS THRU @ RR
SHEET NUMBER
4040 N CENTRAL EXPY,
SUITE 720
DALLAS, TEXAS 75204
t 314.302.6864
www.modusarchitecture.com
FOR INFORMATION
PURPOSES ONLY. NOT TO
BE USED IN ANY CAPACITY
FOR BIDDING, PERMITTING,
OR CONSTRUCTION
REVISIONS:
SHEET NAME
ISSUE DATE:
16
2
5
L
A
N
C
A
S
T
E
R
D
R
I
V
E
GR
A
P
E
V
I
N
E
,
T
E
X
A
S
7
6
0
5
1
A822
TYPICAL
CASEWORK
DETAILS
PE
R
M
I
T
S
E
T
CO
O
K
C
H
I
L
D
R
E
N
'
S
12/19/2024
1 1/2" = 1'-0"3 MAGNETIC LOCK LOCATIONS
1 1/2" = 1'-0"2 PLAN DETAIL - COUNTER TOP @ EXPOSED FINISH END
1 1/2" = 1'-0"4 LAMINATE COUNTERTOP SEAM
1 1/2" = 1'-0"5 PLAN DETAIL - DOOR REVEAL
1 1/2" = 1'-0"8 SECTION DETAIL - TOP TRIM
1 1/2" = 1'-0"7 PLAN DETAIL - SIDE TRIM
1 1/2" = 1'-0"6 SECTION DETAIL - LIGHT VALANCE
1 1/2" = 1'-0"9 PLAN DETAIL - INSIDE CORNER
GENERAL NOTE: ALL DIMENSIONS TO BE VERIFIED BY ANTON PRIOR TO FABRICATION. COORDINATE ALL MILLWORK WITH EQUIPMENT SPECIFICATIONS. PROVIDE IN-WALL BLOCKING AS REQ.
CASTERS ZORO G55700201 PLATE CASTER, 2" DIA BLACK/ZINC ANTON USE FOR PRINTER CART
Z-CLIP MF625-1-1/2 1-1/2" Z-CLIP 5/8" LIFT OFF MILL FINISH ANTON
CLOSET ROD KV 751 Ø1-1/16 CLOSET ROD CHROME ANTON
CLOSET FLANGE KV 734 Ø1-1/16 CLOSET ROD FLANGE CHROME ANTON
LOCKER NAME TAG NAPTAGS PG547 ALUMA-TOUGH LOCKER TAG 1-1/2" DIA BRUSHED ANTON
COUNTER SUPPORT A&M HARDWARE HYB (1.5) XX 1.5" HYBRID BRACKET WHITE ANTON FOR USE ON OPEN KNEE SPACES ON GYP WALLS BY OTHERS
COUNTER SUPPORT A&M HARDWARE C FLAT XX (2.0)2.0" CONCEALED FLAT BRACKET WHITE ANTON FOR USE IN TEAM WORK AND RECEPTION DESK W ALLS BUILT BY ANTON
PULL-1 4" WIRE PULL DULL CHROME ANTON
TRASH GROMMETS DOUG MOCKETT TM2B Ø6" X 2" STAINLESS STEEL GROMMET STAINLESS STEEL ANTON
GROMMETS Ø2" GROMMET WHITE ANTON WIRE GROMMENTS TO BE CUT IN FIELD. VERIFY WITH OWNER FOR FINAL LOCATIONS
SHELF BRACKETS KV 187-12 12" SHELF BRACKETS ANOCHROME ANTON
SHELF STANDARD KV 87-84 84" EXTRA HEAVY-DUTY STANDARDS ANOCHROME ANTON
ANGLE STRIKE OLYMPUS 12-2-26D LOCK CATCH ZINC ANTON USED FOR NATIONAL CAM LOCK OR OLYMPUS PAD LOCKABLE LOCKER LOCK
LOCKER LOCK OLYPMUS DCP-US26D PADLOCKABLE CAM LOCK SATIN CHROME ANTON
TOT LOCK SAFETY 1ST HS133 MAGNETIC LOCK WHITE ANTON
KEY LOCK NATIONAL C8053-14A CAM LOCK NICKEL ANTON
SHELF SUPPORTS KV 256 5MM SPOON SHELF REST CHROME ANTON
ELBOW CATCH IVES SP2-A92 ANTON USED AT PAIR OF DOORS WITH NATIONAL LOCK
DWR SLIDE ACCURIDE 3832C FULL EXTENSION 100LB DRAWER SLIDE ZINC ANTON
BASE PLATE SALICE DOMNI 2MM BASE PLATE ZINC ANTON
HINGE-2 SALICE 94 DEGREE SELF CLOSE HINGE ZINC ANTON NOTE: USE ANGLE RESTRICTION CLIP, USE ADJACENT TO TRIM STRIPS
HINGE-1 SALICE C2R9A99 120 DEGREE SELF CLOSE HINGE ZINC ANTON
DESIGNATION MANUFACTURER MANUFACTURER PART # DESCRIPTION FINISH PROVIDER *SPECIAL ORDER / LONG LEAD
MILLWORK HARDWARE SCHEDULE
1 1/2" = 1'-0"10 FINISH DETAIL - FACE OF TRANSACTION TOP
SHEET NUMBER
4040 N CENTRAL EXPY,
SUITE 720
DALLAS, TEXAS 75204
t 314.302.6864
www.modusarchitecture.com
FOR INFORMATION
PURPOSES ONLY. NOT TO
BE USED IN ANY CAPACITY
FOR BIDDING, PERMITTING,
OR CONSTRUCTION
REVISIONS:
SHEET NAME
ISSUE DATE:
16
2
5
L
A
N
C
A
S
T
E
R
D
R
I
V
E
GR
A
P
E
V
I
N
E
,
T
E
X
A
S
7
6
0
5
1
A901
FINISH LEGEND
PE
R
M
I
T
S
E
T
CO
O
K
C
H
I
L
D
R
E
N
'
S
12/19/2024
MS2 ROLLER SHADE MANUF: HUNTER DOUGLAS
TYPE: ARCHITECTURAL E SCREEN 7501
COLOR: WHITE PEARL, 1% OPENNESS
WINDOWS, TYP. U.N.O.96" RAILROADED ONE WIDTH NO SEAM. MOUNT TO UNDERSIDE OF GYP BD SOFFIT AT WINDOW OPENING. DO NOT
MOUNT TO WINDOW FRAME
F2 GLASS FILM MANUF: 3M
TYPE: FASARA GLASS FINISHES; OPAQUE MATTE WINDOW FILM
COLOR: WHITE SH2MA0W
VARIES INSTALL FILM ON INTERIOR FACE OF GLAZING WHERE PARTITION IS TO BE BUILT INFRONT OF WINDOW.
F2 GLASS FILM MANUF: 3M
TYPE: FASARA GLASS FINISHES; SEMI-TRANSPARENT FROST WINDOW FILM
COLOR: DUSTED CRYSTAL; 7725SE-314
WINDOW TREATMENT
GYP PAINTED GYP. BD. CEILING TYPE: ZERO VOC, HARMONY INTERIOR LATEX
COLOR: PT10, U.N.O.
TYPICAL PAINT TO BE ROLLER APPLIED, LIGHT STIPPLE TEXTURE, EGGSHELL FINISH
ACT ACOUSTICAL CEILING TILE MANUF: ROCKFON
STYLE: ARCTIC SQUARE TEGULAR NARROW
ITEM: 620
TILE SIZE: 24" X 24"
GRID: 15/16" SUSPENSION SYSTEM
TYPICAL ALL EXPOSED CUT TILE EDGES SHALL BE PAINTED W/ SUPERCOAT TOUCH-UP PAINT
CEILING
RP6 RESIN PANEL MANUF: 3FORM
TYPE: CHROMA
COLOR: MIDNIGHT B52
THICKNESS: 1/2"
WAITING
SS01 ALTERNATE 03: SOLID
SURFACAE
MANUF: FORMICA
TYPE: EVERFORM SOLID SURFACE
COLOR: SEA GLASS 505
COUNTER TOPS, TYP. U.N.O.
RE: SCHEDULE OF ALTERNATES
RE: SCHEDULE OF ALTERNATES
PL120 PLASTIC LAMINATE MANUF: PIONITE
TYPE: MELCORE II, TEXTURED SUEDE(SD) FINISH
COLOR: ROYAL BLUE SB009-SD
RECEPTION, MA STATION
PL82 PLASTIC LAMINATE MANUF: NEVAMAR
TYPE: PLASTIC LAMINATE, ARP (T) FINISH
COLOR: BEIGE RENAISSANCE WM8258T
DOORS AND VERTICAL MILLWORK, TYP. U.N.O.
PL134 PLASTIC LAMINATE MANUF: WILSONART
TYPE: PLASTIC LAMINATE, 60 MATTE FINISH
COLOR: CATALINA 13092
COUNTER TOPS, TYP. U.N.O.
PL2 PLASTIC LAMINATE MANUF: PIONITE
TYPE: TEXTURED SUEDE(SD) FINISH
COLOR: ANGEL WHITE SW826-SD
RECEPTION, MA STATION
MILLWORK
FRP1 FIBER REINFORCED PANEL MANUF: US FRP
PRODUCT: 4X8 FRP INDURO, SPECTURM CLASS A
COLOR: DESIGNER WHITE
EVS
IRL6 RIGID WALL PROTECTION SHEET MANUF: INPRO
TYPE: 0.040" THICK RIGID WALL PROTECTION SHEET, VELVET TEXTURE
COLOR: PORCELAIN BLUE 0379
SIZE: 4' X 8' SHEETS
EXAM, WAITING, RESTROOMS INSTALL FULL SHEETS HORIZONTALLY. OVERLAP RUBBER BASE BY 1". TOP OF SHEET TO BE AT 4'-3" AFF. DO NOT
INSTALL WHERE LAMINATE BACKSPLASH OCCURS. UTILIZE COLOR-MATCH J-MOLD TOP CAP AND SEAL SEAM WITH
CAULK. UTILIZE T-TRIM PIECES AT VERTICAL SEAMS WHERE PANELS ALIGN AND AT INSIDE CORNER CONDITIONS.
EG2 END GUARD MANUF: INPRO
TYPE: 160D SURFACE MOUNT END GUARD, PARTIAL HEIGHT, 90 DEGREE ANGLE
COLOR: PORCELAIN BLUE 0379
SIZE: 3" VINYL, 1/4" RADIUS COVER
RE: FINISH FLOOR PLAN
EG1 END GUARD MANUF: INPRO
TYPE: 160D SURFACE MOUNT END GUARD, FULL HEIGHT, 90 DEGREE ANGLE
COLOR: PORCELAIN BLUE 0379
SIZE: 3" VINYL, 1/4" RADIUS COVER
RE: FINISH FLOOR PLAN INSTALL CORNER GUARD ABOVE WALL BASE, U.N.O.
CG3 CORNER GUARD MANUF: INPRO
TYPE: SURFACE MOUNT CORNER GUARD, PARTIAL HEIGHT, CUSTOM ANGLE
COLOR: PORCELAIN BLUE 0379
SIZE: 3" VINYL, 1/4" RADIUS COVER
RE: FINISH FLOOR PLAN INSTALL CORNER GUARD ABOVE WALL BASE, U.N.O
ALIGN TOP OF CORNER GUARD WITH ADJACENT RIGID SHEET (51" A.F.F.)
CG2 CORNER GUARD MANUF: INPRO
TYPE: 150 SURFACE MOUNT CORNER GUARD, PARTIAL HEIGHT, 90 DEGREE ANGLE
COLOR: PORCELAIN BLUE 0379
SIZE: 3" VINYL, 1/4" RADIUS COVER
RE: FINISH FLOOR PLAN INSTALL CORNER GUARD ABOVE WALL BASE, U.N.O
ALIGN TOP OF CORNER GUARD WITH ADJACENT RIGID SHEET (51" A.F.F.)
CG1 CORNER GUARD MANUF: INPRO
TYPE: 150 SURFACE MOUNT CORNER GUARD, FULL HEIGHT, 90 DEGREE ANGLE
COLOR: PORCELAIN BLUE 0379
SIZE: 3" VINYL, 1/4" RADIUS COVER
RE: FINISH FLOOR PLAN INSTALL CORNER GUARD ABOVE WALL BASE, U.N.O.
WT5 WOOD TRIM PAINTED TO MATCH PT2
PAINTED WITH ROLLER APPLIED INTERIOR LATEX PAINT, SMOOTH TEXTURE, SEMI-GLOSS FINISH
SIZE: 2" X 3/8" D
WAITING INSTALL CONTINOUSLY AROUND WAITING ROOM WITH STENCIL DETAIL ABOVE, RE: INTERIOR ELEVATIONS
TOP OF WOOD TRIM TO BE ALIGNED WITH THE TOP OF METAL DOOR FRAME
RBC39 RUBBER WALL BASE MANUF: ROPPE
STYLE: 4" PINNACLE COVED BASE
COLOR: P110 BROWN
SIZE: 120' CONTINOUS ROLL
TYP. THROUGHOUT U.N.O.TRANSITIONS AT INSIDE CORNERS ONLY
WALL PROTECTION
PT135E PROMAR INDUSTRIAL DTM
ACRYLIC PAINT
MANUF: SHERWIN WILLIAMS - PPG PAINT COLOR MATCH
COLOR: 1005-7 DARK GRANITE
DOOR FRAMES, TYP. U.N.O.ROLLER APPLIED, SMOOTH TEXTURE, SEMI GLOSS FINISH
PT37 PROMAR 200 ZERO VOC
INTERIOR LATEX PAINT
MANUF:SHERWIN WILLIAMS - BENJAMIN MOORE COLOR MATCH
COLOR: BM425 LIME TWIST
CHECK IN STENCIL (SQUARE DOT)ROLLER APPLIED, LIGHT STIPPLE TEXTURE, EGGSHELL FINISH
RE: INTERIOR ELEVATIONS, FINISH FLOOR PLAN FOR LOCATION OF APPLICATION
PT29E PROMAR INDUSTRIAL DTM
ACRYLIC PAINT
MANUF: SHERWIN WILLIAMS - PPG PAINT COLOR MATCH
COLOR: 1179-1 MISTY MORN
RESTROOM WALL PAINT, TYP. U.N.O.ROLLER APPLIED, LIGHT STIPPLE TEXTURE, EGGSHELL FINISH
RE: INTERIOR ELEVATIONS, FINISH FLOOR PLAN FOR LOCATION OF APPLICATION
PT28 PROMAR 200 ZERO VOC
INTERIOR LATEX PAINT
MANUF:SHERWIN WILLIAMS - BENJAMIN MOORE COLOR MATCH
COLOR: BM2049-70 ICING ON THE CAKE + 50% WHITE
CORRIDORS, CHECK IN STENCIL (BACKGROUND)ROLLER APPLIED, LIGHT STIPPLE TEXTURE, EGGSHELL FINISH
RE: INTERIOR ELEVATIONS, FINISH FLOOR PLAN FOR LOCATION OF APPLICATION
PT21 PROMAR 200 ZERO VOC
INTERIOR LATEX PAINT
MANUF:SHERWIN WILLIAMS - BENJAMIN MOORE COLOR MATCH
COLOR: BM2067-70 WHITE SATIN
WAITING, EXAM ROLLER APPLIED, LIGHT STIPPLE TEXTURE, EGGSHELL FINISH
RE: INTERIOR ELEVATIONS, FINISH FLOOR PLAN FOR LOCATION OF APPLICATION
PT157 PROMAR 200 ZERO VOC
INTERIOR LATEX PAINT
MANUF: SHERWIN WILLIAMS
COLOR: SW6787 FOUNTAIN
CHECK IN STENCIL (DASH STRIPE)ROLLER APPLIED, LIGHT STIPPLE TEXTURE, EGGSHELL FINISH
RE: INTERIOR ELEVATIONS, FINISH FLOOR PLAN FOR LOCATION OF APPLICATION
PT10E PROMAR INDUSTRIAL DTM
ACRYLIC PAINT
MANUF: SHERWIN WILLIAMS - PPG PAINT COLOR MATCH
COLOR: 90-474 CEILING WHITE
RESTROOM CEILING PAINT, TYP. U.N.O.ROLLER APPLIED, LIGHT STIPPLE TEXTURE, EGGSHELL FINISH
RE: INTERIOR ELEVATIONS, FINISH FLOOR PLAN FOR LOCATION OF APPLICATION
PT09 PROMAR INDUSTRIAL DTM
ACRYLIC PAINT
MANUF: SHERWIN WILLIAMS - PPG PAINT COLOR MATCH
COLOR: SW7664 STEELY GRAY
EXTERIOR DOOR FRAMES ROLLER APPLIED, SMOOTH TEXTURE, SEMI GLOSS FINISH
WALL
VT127 LUXURY VINYL TILE MANUF: PATCHCRAFT
STYLE: MATERIAL EDIT, CURVED 1730V
COLOR: PORCELAIN SPRUCE 00110
SIZE: 9" X 36"
INSTALLATION: RANDOM STAGGER; RUN PLANKS PERPENDICULAR TO FIELD FLOORING
TYP. THROUGHOUT U.N.O.
CT55 CARPET TILE MANUF: INTERFACE
STYLE: CUSTOM STEP ASIDE, 141750250
COLOR: BLUE 251350-022
SIZE: 50CM X 50CM
INSTALLATION: BRICK
OFFICES, ADMIN SPACES SEAM SEAL EDGES OF CARPET PER MANUFACTURER'S INSTRUCTIONS.
FLOORING
FIN. CODE MATERIAL MANUFACTURER / DESCRIPTION GENERAL LOCATION NOTES
INTERIOR FINISH SCHEDULE
TV
TV
FLOOR FINISH:
A. ALL FLOOR FINISH MATERIALS TO BE
INSTALLED TIGHT TO DRYWALL AND
CASEGOODS
B. CENTER ALL FLOOR TRANSITIONS ON THE CL
OF DOORS U.N.O.
WALL BASE:
A. ALL RUBBER BASE SHALL BE SEALED TIGHT
TO FINISHED FLOOR MATERIAL.
B. PROVIDE SCHEDULED BASE ALONG BOTTOM
OF EXPOSED FRONTS, BACKS, SIDES, AND
ENDS OF ALL FIXED CABINETS, PEDESTALS,
VERTICAL SUPPORT PANELS, KNEE SPACES,
ETC., U.N.O. ON THE INTERIOR ELEVATIONS.
C. WHERE WALL CERAMIC TILE MEETS FLOOR,
PROVIDE A WATER RESILIENT SLICONE
CAULKING AT JOINT.
WALL FINISH:
A. WALL TEXTURE SHALL BE LEVEL 4H ROLLER
FINISH, UNLESS NOTED OTHERWISE.
B. PAINTED ALL ELECTRICAL AND ACCESS WALL
PANELS TO MATCH ADJACENT WALL COLOR.
CEILING:
A. REFER TO REFLECTED CEILING PLANS FOR
ALL CEILING HEIGHTS.
B. PAINT ALL ACCESS PANELS IN CEILING TO
MATCH ADJACENT CEILING COLOR.
DOORS/WINDOWS:
A. REFER TO DOOR SCHEDULE FOR FINISH OF
INTERIOR HOLLOW METAL DOOR & FRAME,
AND INTERIOR SURFACE OF EXTERIOR
HOLLOW METAL DOOR & FRAME.
MILLWORK:
A. PULLS ARE SHOWN FOR LOCATION ONLY, SEE
PROJECT MANUAL FOR HARDWARE STYLE
AND TYPE.
B. COUNTERTOPS, BASE AND UPPER CABNETS
TO RECEIVE PLASTIC LANIMATE U.N.O.
C. ALL KNEE SPACES ARE GREATER THAN 4'-0"
REQUIRE AN ANGLE SUPPORT(S).
COORDINATE FINAL INSTALLATION WITH
UNDER COUNTER FILE CABINETS.
D. ALL CABINET DOORS TO BE EQUAL SIZES
WITH MAXIMUM DIMENSIONS AS SHOWN AND
A MINIMUM OF 12" U.N.O.
E. REFER TO FLOOR PLANS FOR OVERALL
DIMENSIONS AND ADJUST CABINET
DIMENSIONS ACCORDINGLY (FIELD VERIFY
ALL DIMENSIONS BEFORE BUILDING
MILLWORK).
F. FINISH ALL EXPOSED & SEMI-EXPOSED
CABINET EDGES.
G. ALL MILLWORK TO HAVE MELAMINE
INTERIORS.
H. PROVIDE DOOR BUMPER GUARDS AT ALL
CABINETS DOORS & DRAWERS.
I. LOCATE CABINET DOOR PULLS SO THAT
SCREWS DO NOT DAMAGE MILLWORK AT
INTERIOR CABINETS.
J. COUNTERTOP AND SPLASH TO BE
CONSTRUCTED OF PLYWOOD.
K. INCLUDE LOCKS AS NOTED ON DRAWINGS.
CONFIRM MILLWORK KEYING REQUIREMENTS
WITH OWNER.
L. PROVIDE FULL LINE BORE FOR ADJUSTABLE
SHELVES.
M. ALL MILLWORK EDGE BANDING TO MATCH
COLOR OF ADJACENT P LAM.
GENERAL NOTES
INTERIOR FINISH PLAN
MILLWORK FINISH TAG
FLOOR FINISH
BASE FINISH
WALL FINISH
CEILING FINISH
ROOM FINISH TAG
NOT IN CONTRACT
FLOORING FINISH PATTERN
DIRECTION
INTERIOR FINISH
PLAN LEGEND
XXXX
CORNER GUARD, RE: FINISH
LEGEND
N.I.C.
N.I.C.
EXAM 12
ACT
PT21, IRL6
RBC39
VT127
119
STORAGE
ACT
PT21
RBC39
VT127
120EXAM 13
ACT
PT21, IRL6
RBC39
VT127
121
EXAM 14
ACT
PT21, IRL6
RBC39
VT127
122
EXAM 11
ACT
PT21, IRL6
RBC39
VT127
118
EXAM 10
ACT
PT21, IRL6
RBC39
VT127
117
EXAM 09
ACT
PT21, IRL6
RBC39
VT127
116
EXAM 08
ACT
PT21, IRL6
RBC39
VT127
115
IT/ELEC
-
PT21
RBC39
VT127
114
EXAM 07
ACT
PT21, IRL6
RBC39
VT127
113
EXAM 06
ACT
PT21, IRL6
RBC39
VT127
110
EXAM 03
ACT
PT21, IRL6
RBC39
VT127
106
EXAM 02
ACT
PT21, IRL6
RBC39
VT127
105EXAM 01
ACT
PT21, IRL6
RBC39
VT127
104
STAFF TLT
PT10E
PT29E, IRL6
RBC39
VT127
111
BREAKROOM
ACT, PT21
PT21
RBC39
VT127
112
MA STATION
ACT, PT28
PT28
RBC39
VT127
127
EXAM 05
ACT
PT21, IRL6
RBC39
VT127
109
EXAM 04
ACT
PT21, IRL6
RBC39
VT127
108
EXAM 15
ACT, PT21
PT21, IRL6
RBC39
VT127
123
NURSING
ACT
PT21
RBC39
VT127
124
WAITING
ACT, PT28
PT21, PT28, IRL6
RBC39
VT127
100
LAB
ACT, PT28
PT28
RBC39
VT127
128
RECEPTION
ACT, PT28
PT21
RBC39
CT55
125
SHARED
OFFICE
ACT, PT21
PT21
RBC39
CT55
107
STORAGE
ACT
PT21
RBC39
VT127
130
VITALS
ACT
PT21
RBC39
VT127
103
TLT
PT10E
PT29E, IRL6
RBC39
VT127
132
TLT
PT10E
PT29E, IRL6
RBC39
VT127
129
OFFICE
ACT
PT21
RBC39
CT55
126
TLT
PT10E
PT29E, IRL6
RBC39
VT127
102
EVS
-
FRP1
RBC39
VT127
131
101
RISER
ROOM
CT55
VT127
CT
5
5
VT
1
2
7
PT
2
8
PT
2
8
PT
2
8
PT21
PT21
PT21
PT
2
1
1 1
1
1
1
1
CG1
CG1
CG1
CG1
EG1
EG1
EG1
EG1EG1
CG1 EG1
CG1
CG1
CG1
CG1
CG1
EG1
EG1
EG1
EG1
CG1
EG1
CG1
CG3
EG1
EG1
EG1
EG1
EG1
EG1
EG1 EG1
EG1
CG1
CG1
CG1
CG1
CG1CG1
CG1
CG1
EG1 EG1
EG1 CG1
EG1
CG1 CG1
CG1
CG1
CG1
EG2
CG2
CG1CG1EG1EG1
CG2
CG2
CG2
PT21
CG1
2 2 2
2
2
2
2
2222222
2
LVT FLOORING AS SCHED.SCHLUTER SCHIENE, SATIN
NICKEL ANODIZED ALUM. (AT)
CARPET AS SCHED.
UNDERLAYMENT TO BRING
FLOORING FLUSH TO CARPET,
JOHNSONITE SUBFLOOR
LEVELER SYSTEM
1
NOTES BY NUMBER
FINISH FLOOR PLAN
WT5 TO BE APPLIED CONTINUOUSLY BETWEEN
WALLS AND DOORS. ALIGN TOP OF WT5 WITH
TOP OF DOOR FRAME. PROVIDE STENCIL
PATTERN ABOVE, TYP. RE: WALL STENCIL DETAIL.
VERIFY ALL STENCIL DETAIL LOCATIONS WITH
OWNER PRIOR TO PAINTING.
2 REFER TO FINISH LEGEND FOR EXTENTS OF IRL6.
7'-2"
LINE OF CEILING ABOVE
3"
1 1/2"
1 1/2"
1 1/2"
1 1/2"
3"
END OF WALLEND OF WALL
1'
-
2
"
1
1
/
2
"
1
1
/
2
"
1
1
/
2
"
PT37 PT157 PT37
WT5
PT28
PT21
PT28
SHEET NUMBER
4040 N CENTRAL EXPY,
SUITE 720
DALLAS, TEXAS 75204
t 314.302.6864
www.modusarchitecture.com
FOR INFORMATION
PURPOSES ONLY. NOT TO
BE USED IN ANY CAPACITY
FOR BIDDING, PERMITTING,
OR CONSTRUCTION
REVISIONS:
SHEET NAME
ISSUE DATE:
16
2
5
L
A
N
C
A
S
T
E
R
D
R
I
V
E
GR
A
P
E
V
I
N
E
,
T
E
X
A
S
7
6
0
5
1
A911
FINISH FLOOR
PLAN & FINISH
DETAILS
PE
R
M
I
T
S
E
T
CO
O
K
C
H
I
L
D
R
E
N
'
S
12/19/2024
PLAN
NORTH
TRUE
NORTH
1/4" = 1'-0"1 FINISH FLOOR PLAN
3" = 1'-0"2 FLOORING TRANSITION - CARPET TO LVT FLOORING
1" = 1'-0"3 WALL STENCIL DETAIL
NOTES BY SYMBOL: " "
1.REPLACE EXISTING 10-TON ROOFTOP UNIT WITH NEW PACKAGED ROOFTOP
UNIT. UTILIZE EXISTING ROOF CURB AND ROOF OPENINGS. PROVIDE NEW
ROOF CURB IF EXISTING CURB IS NOT COMPATIBLE WITH NEW UNIT.
2.PROVIDE AS ALTERNATE PRICE: EXTEND SUPPLY AND RETURN AIR DUCT TO
ABOVE AREA NOT IN CONTRACT AND CAP FOR FUTURE TENANT.
3.ROUTE 6"Ø EXHAUST AIR DUCT UP THROUGH ROOF AND TERMINATE WITH
ROOF CAP. INSTALL MINIMUM 10'-0" FROM ANY FRESH AIR INTAKE.
4.ROUTE 3 4" CONDENSATE DRAIN TO MOP SINK AND TERMINATE WITH AIR GAP.
5.ROUTE AND SIZE REFRIGERANT PIPING FROM OUTDOOR UNIT TO INDOOR
UNIT PER MANUFACTURER'S INSTALLATION RECOMMENDATIONS.
6.THERMOSTAT CONTROLLER FOR RTU-1, 2 & 3.
7.PROVIDE REMOTE TEMPERATURE SENSOR. WIRE BACK TO THERMOSTAT
CONTROLLER IN RECEPTION AREA.
A.NOT ALL DUCTWORK, PIPING, AND ACCESSORIES ARE NECESSARILY SHOWN ON THIS
DRAWING, BUT WHAT WAS DEEMED NECESSARY TO SHOW INTENT OF WORK
INVOLVED IN THIS PROJECT. REFER TO ALL OTHER PLANS, SECTIONS, DETAILS,
SCHEDULES AND SPECIFICATIONS FOR COMPLETE SYSTEM REQUIREMENTS.
B.COORDINATE ALL PENETRATIONS OF FLOOR, ROOF, WALLS, ETC. WITH GENERAL
CONTRACTOR. ALL PENETRATIONS THROUGH FIRE/SMOKE RATED CONSTRUCTION
SHALL BE SEALED WITH A FIRE RATED CAULK EQUAL TO OR EXCEEDING THE
CONSTRUCTION FIRE RATING.
C.FLEXIBLE AIR DUCTS SHALL CONFORM TO UL181 IN ACCORDANCE WITH SECTION
603.6 OF THE 2015 EDITION OF THE INTERNATIONAL MECHANICAL CODE. LENGTH OF
FLEX DUCT SHALL NOT EXCEED 5 FT.
D.ALL MECHANICAL EQUIPMENT SHALL BE LABELED AS TO THE AREA(S) SERVED IN
ACCORDANCE WITH SECTION 304.12 OF THE 2015 EDITION OF THE INTERNATIONAL
MECHANICAL CODE.
E.PROVIDE ACCESS DOORS OR OTHER MEANS OF APPROVED ACCESS TO ALL FIRE
DAMPERS AND FIRE/SMOKE DAMPERS. ACCESS DOORS SHALL BE LABELED ON THE
ACCESS DOOR AND ON THE CEILING BELOW.
F.PROVIDE AND INSTALL BALANCING DAMPER AT EACH BRANCH TAKE-OFF OF SUPPLY
AND EXHAUST AIR SYSTEMS. PROVIDE AND INSTALL BALANCING DAMPER AT EACH
BRANCH TAKE-OFF OF RETURN SYSTEMS WHERE INDICATED.
G.MOUNT SPACE TEMPERATURE SENSORS, THERMOSTATS, OCCUPANCY SENSORS,
AND REMOTE CONTROL DEVICES WITH CENTERLINE AT 46” AFF UNLESS OTHER WISE
INDICATED.
H.COORDINATE WITH GENERAL CONTRACTOR TO PROVIDE ROOF ACCESS FOR
MAINTENANCE OF ROOFTOP MECHANICAL EQUIPMENT.
I.COORDINATE WITH ELECTRICAL CONTRACTOR TO PROVIDE 120V OUTLET WITHIN 25
FT. OF ALL ROOFTOP AND EXTERIOR MECHANICAL EQUIPMENT.
J.ALL FRESH AIR INTAKES AND EXHAUST OPENINGS SHALL HAVE 1/4" MESH BIRD
SCREENS.
K.PROVIDE BALANCING REPORT IN ACCORDANCE WITH THE 2015 EDITION OF THE
INTERNATIONAL MECHANICAL CODE. SUBMIT TO THE ARCHITECT FOR FINAL
APPROVAL. PROVIDE BALANCING REPORT TO INSPECTOR AT TIME OF HEATING FINAL
INSPECTION.
L.DUCTWORK SHALL BE SEALED IN ACCORDANCE WITH THE SPECIFICATIONS AND THE
2015 EDITION OF THE INTERNATIONAL ENERGY CONSERVATION CODE.
M.ALL INTERIOR EXPOSED DUCT SHALL BE INTERNALLY LINED AND WITH PAINT GRIP
FINISH. REFER TO ARCHITECT FOR FINAL FINISH OF DUCTWORK.
N.COORDINATE REQUIREMENTS ASSOCIATED WITH RELOCATION AND INSTALLATION OF
OWNER PROVIDED EQUIPMENT WITH OWNER PRIOR TO BID.
GENERAL NOTES:
119
EXAM 12
120
STORAGE
121
EXAM 13
122
EXAM 14 118
EXAM 11
117
EXAM 10
116
EXAM 09
115
EXAM 08
114
IT/ELEC
113
EXAM 07
110
EXAM 06
106
EXAM 03
105
EXAM 02
104
EXAM 01
111
STAFF TLT
112
BREAKROOM
127
MA
STATION
109
EXAM 05
108
EXAM 04
123
EXAM 15 124
NURSING
100
WAITING
128
LAB
125
RECEPTION
107
SHARED
OFFICE
103
VITALS
132
TLT
129
TLT
126
OFFICE
130
STORAGE
102
TLT
131
EVS
101
RISER
ROOM
20X14
12X14
18X14
12X14
10"Ø
38X16
20X14
18
X
1
2
10
X
1
0
18X14
10
X
1
0
32
X
1
8
32
X
1
6
32X16
32X18
30X16
14X12
18
X
1
4
26
X
1
4
14X12
22X1218X12
14X14
16X12
28
X
1
4
RTU-3
RTU-1
RTU-2
FLOOR PLAN - MECHANICAL1
REVISIONS:
4040 N CENTRAL EXPY,
SUITE 720
DALLAS, TEXAS 75204
t 314.302.6864
www.modusarchitecture.com
16
2
5
L
A
N
C
A
S
T
E
R
D
R
I
V
E
GR
A
P
E
V
I
N
E
,
T
E
X
A
S
7
6
0
5
1
PE
R
M
I
T
CO
O
K
C
H
I
L
D
R
E
N
'
S
TEXAS REGISTRATION # F-20374
V3 PROJECT #:24567.001
SHEET NUMBER
SHEET NAME
ISSUE DATE 12/19/2024
M1.01
FLOOR PLAN -
MECHANICAL
12/19/2024
REVISIONS:
4040 N CENTRAL EXPY,
SUITE 720
DALLAS, TEXAS 75204
t 314.302.6864
www.modusarchitecture.com
16
2
5
L
A
N
C
A
S
T
E
R
D
R
I
V
E
GR
A
P
E
V
I
N
E
,
T
E
X
A
S
7
6
0
5
1
PE
R
M
I
T
CO
O
K
C
H
I
L
D
R
E
N
'
S
TEXAS REGISTRATION # F-20374
V3 PROJECT #:24567.001
SHEET NUMBER
SHEET NAME
ISSUE DATE 12/19/2024
M2.01
SCHEDULES & DETAILS -
MECHANICAL
12/19/2024
AIR DEVICE CONNECTION DETAIL4
EXHAUST FAN DETAIL - CEILING MOUNT3
SHOULD BE CONTINUOUS UNDER UNIT.
ROOF DECK AND ROOF INSULATION
ROOF TOP UNIT DETAIL1
EQUIPMENT ROOF CURB
CONDENSATE LINE WITHIN CURB (INSULATED)
SEAL PENETRATION
ROOFTOP HVAC UNIT
SIDE OUTLET CONNECTION
OPEN VENT
CLEANOUT
EPDM RUBBER BOOT ENCLOSURE.
SECURE WITH STAINLESS STEEL
HOSE CLAMPS.
WITH ROOF CURB MANUFACTURER.
THRU ROOF CURB. COORDINATE
3" LONG FACTORY WELDED SLEEVE
PLUMBING FIXTURE/DRAIN.
AS HIGH AS POSSIBLE TO
ROUTE CONDENSATE DRAIN LINE
CLEANOUT CAP (INSULATED)
BELOW ROOF
INSULATE CONDENSATE PIPING
ROOF TOP HVAC UNIT CONDENSATE PIPING DETAIL2
REVISIONS:
4040 N CENTRAL EXPY,
SUITE 720
DALLAS, TEXAS 75204
t 314.302.6864
www.modusarchitecture.com
16
2
5
L
A
N
C
A
S
T
E
R
D
R
I
V
E
GR
A
P
E
V
I
N
E
,
T
E
X
A
S
7
6
0
5
1
PE
R
M
I
T
CO
O
K
C
H
I
L
D
R
E
N
'
S
TEXAS REGISTRATION # F-20374
V3 PROJECT #:24567.001
SHEET NUMBER
SHEET NAME
ISSUE DATE 12/19/2024
M3.01
DETAILS - MECHANICAL
12/19/2024
PLUMBING NOTES BY SYMBOL:
1.CONNECT NEW DOMESTIC HOT AND COLD. CONNECT SANITARY TO
NEAREST EXISTING PLUMBING UTILITIES IN THE AREA. CONTRACTOR TO
FIELD VERIFY EXACT LOCATION AND SIZE PRIOR TO BID.
GENERAL NOTES:
A.CONTRACTOR TO VISIT SITE AND BECOME FAMILIAR WITH ALL EXISTING
CONDITIONS, TO DETERMINE THE EXTENT OF WORK REQUIRED TO
FACILITATE NEW CONSTRUCTION AND INCLUDE ALL SUCH WORK IN HIS/HER
BID. CONTRACTOR TO VERIFY ALL EXISTING CONDITIONS PRIOR TO BID
(INCLUDING BUT NOT LIMITED TO UNDERFLOOR SANITARY LOCATIONS AND
CIVIL CONNECTIONS). CONTRACTOR SHALL NOTIFY ARCHITECT OF ALL
DISCREPANCIES PRIOR ANY INSTALLATIONS.
B.BUILDING SEWERS: BUILDING SEWERS SHALL BE PROVIDED WITH
CLEANOUTS LOCATED NOT MORE THAN 75'-0" APART MEASURED FROM THE
UPSTREAM ENTRANCE OF THE CLEANOUT.
C.CHANGES OF DIRECTION: CLEANOUTS SHALL BE INSTALLED AT EACH
CHANGE OF DIRECTION OF THE BUILDING DRAIN HORIZONTAL WASTE OR
SOIL LINES GREATER THAN 45 DEGREES. WHERE MORE THAN ONE CHANGE
OF DIRECTION OCCURS IN A RUN OF A RUN OF PIPING, ONLY ONE
CLEANOUT SHALL BE REQUIRED FOR EACH 40'-0" FEET OF DEVELOPED
LENGTH OF THE DRAINAGE PIPING. ALL SEWER PIPING SHOWN ON THIS
PLAN IS UNDERFLOOR UNLESS OTHERWISE NOTED.
D.CONCEALED PIPING: CLEANOUTS ON CONCEALED PIPING OR PIPING UNDER
A FLOOR SLAB OR IN A CRAWL SPACE OF LESS THAN 24 INCHES IN HEIGHT
OR A PLENUM SHALL BE EXTENDED THROUGH AND TERMINATE FLUSH WITH
THE FINISHED WALL, FLOOR OR GROUND SURFACE OR SHALL BE
EXTENDED TO THE OUTSIDE OF THE BUILDING. CLEANOUT PLUGS SHALL
NOT BE COVERED WITH CEMENT, PLASTER OR ANY OTHER PERMANENT
FINISH MATERIAL. WHERE IT IS NECESSARY TO CONCEAL A CLEANOUT OR
TERMINATE A CLEANOUT IN AN AREA SUBJECT TO VEHICULAR TRAFFIC,
COVER PLATE, ACCESS DOOR OR CLEANOUT SHALL BE OF AN APPROVED
TYPE DESIGNED AND INSTALLED FOR THIS PURPOSE.
E.VERIFY MAXIMUM PRESSURE IS NOT IN EXCESS OF 55PSI. IF IT IS, PROVIDE
AND INSTALL PRESSURE REDUCING VALVES ON THE NEW LINES TO
PROVIDE A MAXIMUM PRESSURE OF 55 PSI TO THE NEW FIXTURES OR TO
EXISTING FIXTURES BEING REWORKED.
F.ALL WASTE PIPE 212" AND SMALLER SHALL HAVE A SLOPE OF NOT LESS
THAN 1/4" PER FOOT; ALL WASTE PIPE 3" AND LARGER SHALL HAVE NOT
LESS THAN 1/8" PER FOOT SLOPE.
G.ALL PLUMBING PIPE, FIXTURES AND FITTINGS SHALL BE LEAD FREE IN
ACCORDANCE WITH THE "REDUCTION OF LEAD IN DRINKING WATER ACT"
EFFECTIVE JANUARY 4, 2014.
H.REFER TO EQUIPMENT VENDOR/OWNER/ARCHITECT FOR EQUIPMENT AND
FIXTURES BREAKROOM(S). IT SHALL BE THE RESPONSIBILITY OF THE
CONTRACTOR TO COORDINATE WITH THE EQUIPMENT
VENDOR/OWNER/ARCHITECT TO PROVIDE ALL NECESSARY ITEMS FOR A
COMPLETE INSTALLATION. ALL EQUIPMENT SPECIFIED IN THE MEP
DRAWINGS SHALL BE PROVIDED BY THE PLUMBING SUB-CONTRACTOR. ALL
EQUIPMENT SPECIFIED IN THE ARCHITECTURAL DRAWINGS SHALL BE
PROVIDED BY EQUIPMENT VENDOR/OWNER/ARCHITECT.
I.ALL SHUT-OFF VALVES TO BE INSTALLED AND TO BE ACCESSIBLE WITHOUT
THE USE OF A LADDER.
J.ALL WATER AND DRAIN LINES TO AND FROM EQUIPMENT SHALL BE COPPER
WITH A MINIMUM OF 6 INCHES ABOVE FINISH FLOOR FOR CLEANING
PURPOSES.
K.ALL DOMESTIC COLD AND HOT WATER CONNECTION SIZES AND ROUGH-IN
LOCATIONS SHALL BE COORDINATED WITH ARCHITECTURAL DRAWINGS.
L.PROVIDE AHJ APPROVED BACKFLOW PREVENTION DEVICE PRIOR TO ALL
APPLIANCE AND EQUIPMENT CONNECTIONS TO DOMESTIC COLD WATER
SYSTEM. REFER TO PLUMBING BACKFLOW SCHEDULE.
M.NO PVC SHALL BE INSTALLED IN THE RETURN AIR PLENUM SPACE.
X
N.I.C.
N.I.C.
119
EXAM 12
120
STORAGE
121
EXAM 13
122
EXAM 14 118
EXAM 11
117
EXAM 10
116
EXAM 09
115
EXAM 08
114
IT/ELEC
113
EXAM 07
110
EXAM 06
106
EXAM 03
105
EXAM 02
104
EXAM 01
111
STAFF TLT
112
BREAKROOM
127
MA
STATION
109
EXAM 05
108
EXAM 04
123
EXAM 15 124
NURSING
100
WAITING
128
LAB
125
RECEPTION
107
SHARED
OFFICE
103
VITALS
132
TLT
129
TLT
126
OFFICE
130
STORAGE
102
TLT
131
EVS
101
RISER
ROOM
3"FD
WH-1
MS-1
CP-1
3"FD
3"FD
3"FD
3"FD
2" VTR
2" VTR
3" VTR
11
2"
112"
112"
11
2"
3
4"
11
4"
3 4"
112"
112"
11 2"
11 4"
1"1"
1"
11
4"
11 4"3 4"
SK1
SK1
L-2
L-2
L-2
L-2
W-2
W-2
W-2
W-2
SK1
SK1
SK1
SK1
SK1
EWC
1
1
1
1
1
1
1
1
1
1
1
1
SCALE:
FLOOR PLAN - PLUMBING
1/4" = 1'-0"1
REVISIONS:
4040 N CENTRAL EXPY,
SUITE 720
DALLAS, TEXAS 75204
t 314.302.6864
www.modusarchitecture.com
16
2
5
L
A
N
C
A
S
T
E
R
D
R
I
V
E
GR
A
P
E
V
I
N
E
,
T
E
X
A
S
7
6
0
5
1
PE
R
M
I
T
CO
O
K
C
H
I
L
D
R
E
N
'
S
TEXAS REGISTRATION # F-20374
V3 PROJECT #:24567.001
SHEET NUMBER
SHEET NAME
ISSUE DATE 12/19/2024
P1.01
FLOOR PLAN - PLUMBING
12/19/2024
PLUMBING RISER DIAGRAM1PLUMBING RISER DIAGRAM2PLUMBING RISER DIAGRAM 3
PLUMBING RISER DIAGRAM4
FLOOR
3.5" HOUSEKEEPING PAD (TYPICAL)
CIRCULATING PUMP
HOT WATER
RETURN
D
SHUT-OFF VALVE (TYP)
CHECK VALVE (TYP)
THERMAL EXPANSION
TANK EQUAL
PROVIDE PLATFORM TO ALLOW DRAIN
LINE FROM PAN TO SLOPE TO WASTE RECEPTOR.
RUN FULL SIZE DRAIN
LINE TO MOP SINK
AND TURN DOWN.
PRESSURE & TEMP.
RELIEF VALVE
3 4" DRAIN TO
NEAREST FLOOR
DRAIN
WATER HEATER DETAIL5
1
REVISIONS:
4040 N CENTRAL EXPY,
SUITE 720
DALLAS, TEXAS 75204
t 314.302.6864
www.modusarchitecture.com
16
2
5
L
A
N
C
A
S
T
E
R
D
R
I
V
E
GR
A
P
E
V
I
N
E
,
T
E
X
A
S
7
6
0
5
1
PE
R
M
I
T
CO
O
K
C
H
I
L
D
R
E
N
'
S
TEXAS REGISTRATION # F-20374
V3 PROJECT #:24567.001
SHEET NUMBER
SHEET NAME
ISSUE DATE 12/19/2024
P2.01
SCHEDULES & DETAILS -
PLUMBING
ADDENDUM 1 02/17/2025
02/17/2025
WATER HEATER SCHEDULE
THERMOSTATIC MIXING
VALVE SCHEDULE
PIPING MATERIAL SCHEDULEDOMESTIC HOT WATER RECIRCULATION PUMP SCHEDULE
INTERIOR DRAIN SCHEDULE
EQUIPMENT BACKFLOW PREVENTER SCHEDULE
ADDITIONAL PLUMBING FIXTURE SCHEDULE
MINIMUM PIPE CONNECTION SCHEDULE
BACK OF HOUSE PLUMBING FIXTURE SCHEDULE
REVISIONS:
4040 N CENTRAL EXPY,
SUITE 720
DALLAS, TEXAS 75204
t 314.302.6864
www.modusarchitecture.com
16
2
5
L
A
N
C
A
S
T
E
R
D
R
I
V
E
GR
A
P
E
V
I
N
E
,
T
E
X
A
S
7
6
0
5
1
PE
R
M
I
T
CO
O
K
C
H
I
L
D
R
E
N
'
S
TEXAS REGISTRATION # F-20374
V3 PROJECT #:24567.001
SHEET NUMBER
SHEET NAME
ISSUE DATE 12/19/2024
P2.02
SCHEDULES & DETAILS -
PLUMBING
12/19/2024
12/19/2024
119
EXAM 12
120
STORAGE
121
EXAM 13
122
EXAM 14 118
EXAM 11
117
EXAM 10
116
EXAM 09
115
EXAM 08
114
IT/ELEC
113
EXAM 07
110
EXAM 06
106
EXAM 03
105
EXAM 02
104
EXAM 01
111
STAFF TLT
112
BREAKROOM
127
MA
STATION
109
EXAM 05
108
EXAM 04
123
EXAM 15 124
NURSING
100
WAITING
128
LAB
125
RECEPTION
107
SHARED
OFFICE
103
VITALS
132
TLT
129
TLT
126
OFFICE
130
STORAGE
102
TLT
131
EVS
101
RISER
ROOM
WH-1
CP-1
NOTES BY SYMBOL:
GENERAL NOTES:
FLOOR PLAN - POWER1 REVISIONS:
4040 N CENTRAL EXPY,
SUITE 720
DALLAS, TEXAS 75204
t 314.302.6864
www.modusarchitecture.com
16
2
5
L
A
N
C
A
S
T
E
R
D
R
I
V
E
GR
A
P
E
V
I
N
E
,
T
E
X
A
S
7
6
0
5
1
PE
R
M
I
T
CO
O
K
C
H
I
L
D
R
E
N
'
S
TEXAS REGISTRATION # F-20374
V3 PROJECT #:24567.001
SHEET NUMBER
SHEET NAME
ISSUE DATE 12/19/2024
E1.02
FLOOR PLAN - POWER
12/19/2024
12/19/2024
RECEPTACLE GROUNDING DETAIL1
ARRANGEMENT FOR NOISE CONTROL
BACK TO BACK ELECTRICAL BOX
2
REVISIONS:
4040 N CENTRAL EXPY,
SUITE 720
DALLAS, TEXAS 75204
t 314.302.6864
www.modusarchitecture.com
16
2
5
L
A
N
C
A
S
T
E
R
D
R
I
V
E
GR
A
P
E
V
I
N
E
,
T
E
X
A
S
7
6
0
5
1
PE
R
M
I
T
CO
O
K
C
H
I
L
D
R
E
N
'
S
TEXAS REGISTRATION # F-20374
V3 PROJECT #:24567.001
SHEET NUMBER
SHEET NAME
ISSUE DATE 12/19/2024
PLUG LOAD CONTROL DETAIL3
E3.01
SCHEDULES & DETAILS -
ELECTRICAL
PARTIAL RISER DIAGRAM4
NOTES BY SYMBOL:
12/19/2024
S F
REVISIONS:
4040 N CENTRAL EXPY,
SUITE 720
DALLAS, TEXAS 75204
t 314.302.6864
www.modusarchitecture.com
16
2
5
L
A
N
C
A
S
T
E
R
D
R
I
V
E
GR
A
P
E
V
I
N
E
,
T
E
X
A
S
7
6
0
5
1
PE
R
M
I
T
CO
O
K
C
H
I
L
D
R
E
N
'
S
TEXAS REGISTRATION # F-20374
V3 PROJECT #:24567.001
SHEET NUMBER
SHEET NAME
ISSUE DATE 12/19/2024
MEP
GENERAL NOTES &
SYMBOLS - MEP
12/19/2024
WOOD TRUSS REINFORCING SCHEDULE
MARK CHORD REINFORCEMENT WEB REINFORCEMENT
"A""B"WEB SIZE
DIRECTION
RIGHTLEFTTOP CHORD BOTT. CHORD "C""D"
NOTES
1. REMOVE AND REINSTALL ALL BRIDGING LINES AND MECHANICAL EQUIPMENT AS NEEDED TO REINFORCE JOIST.
2. WEB QUANTITY AND CONFIGURATION SHOWN IS GENERIC AND DOES NOT REFLECT ACTUAL FIELD CONDITIONS.
3. FASTENERS SHOWN ARE MINIMUM REQUIRED.
LEFT
END
RIGHT
END
TOP CHORD REINFORCING
REF. SCHEDULE
BOTT. CHORD REINFORCING
REF. SCHEDULE
4'-0"16'-0"2x4 RTU2x4 2x4 8'-0" 8'-0"
RT-1
DIAGONAL WEB
REINFORCING
DIAGONAL WEB
REINFORCING
REF. SCHEDULE
BA
C D
119249
JULIE M. BOLDING
salasobrien.com
Registration:
PROJECT STATUS:
ISSUE DATE:
SKETCH NUMBER:
Dallas
12655 North Central Expy, Suite 720
Dallas, TX 75243
F-4111
07/18/2025
SKS-1
TRUSS REINFORCING DIAGRAM AND SCHEDULE
COOK CHILDREN'S GRAPEVINE
1625 LANCASTER DRIVE
GRAPEVINE, TEXAS 76051
07/18/2025
3/4" = 1'-0"SKS-1
1 TRUSS REINFORCING DIAGRAM AND SCHEDULE
A
A
CHORD REINF. EACH
SIDE REF. DTL
FOR SCHEDULE
CHORD REINF. EACH
SIDE REF. DTL
FOR SCHEDULE
NOTES
1. WEB REINFORCING OMITTED FOR CLARITY.
2. IF CHORD CONFIGURATION VARIES FROM WHAT IS SHOWN
NOTIFY ENGINEER PRIOR TO REINFORCING JOISTS.
EXIST. BOTTOM CHORD
EXIST. TOP
CHORD
SECTION "A"
NOTE
1. SPLICE TOP CHORD
REINFORCING PRIOR TO
INSTALLATION.
TYPICAL SPLICE DETAIL
1/SKS-1
1/SKS-1
2x REINFORCING
W/10d NAILS @ 8" O.C.
STAGGERED
EXISTING
WOOD TRUSS
NOTES
1. CHORD REINFORCING
OMITTED FOR CLARITY.
2. IF WEB CONFIGURATION
VARIES FROM WHAT IS
SHOWN NOTIFY
ENGINEER PRIOR TO
REINFORCING JOISTS.
SECTION "A"
EXISTING
WOOD TRUSS2x REINFORCING
W/10d NAILS @8" O.C.
STAGGERED
119249
JULIE M. BOLDING
salasobrien.com
Registration:
PROJECT STATUS:
ISSUE DATE:
SKETCH NUMBER:
Dallas
12655 North Central Expy, Suite 720
Dallas, TX 75243
F-4111
07/18/2025
SKS-2
TRUSS CHORD & WEB REINFORCING
COOK CHILDREN'S GRAPEVINE
1625 LANCASTER DRIVE
GRAPEVINE, TEXAS 76051
07/18/20253/4" = 1'-0"SKS-2
2 TRUSS WEB REINFORCING
3/4" = 1'-0"SKS-2
1 TRUSS CHORD REINFORCING
2 - SIMPSON HGA10 EA. SIDE
OF TRUSS
PROVIDE 2x10 BLOCKING EA.
SIDE OF TRUSS W/ 2 ROWS 16d
NAILS @ 6" O.C. ATTACHED TO
TOP CHORD & WEB
2 ROWS 16d NAILS @ 6" O.C.
(DECK TO BLOCKING)
PROVIDED 2 - 2x12
FLATWISE BLOCKING
BETWEEN TRUSSES @ POST
ATTACHMENT LOCATIONS
RTU RACK DESIGN
& CONSTRUCTION
BY OTHERS
ROOF
TRUSS, TYP.
119249
JULIE M. BOLDING
salasobrien.com
Registration:
PROJECT STATUS:
ISSUE DATE:
SKETCH NUMBER:
Dallas
12655 North Central Expy, Suite 720
Dallas, TX 75243
F-4111
07/18/2025
SKS-3
ROOF TOP A/C RACK CONNX
COOK CHILDREN'S GRAPEVINE
1625 LANCASTER DRIVE
GRAPEVINE, TEXAS 76051
07/18/2025
3/4" = 1'-0"SKS-3
1 ROOF TOP A/C RACK CONNX