Loading...
HomeMy WebLinkAboutNSFR2025-002313ADDRESS 3405 Witt Ct Grapevine, TX 76092 LEGAL Ferguson Place Block 1 Lot 8 PERMIT HOLDER Eason Maykus Kosse M aykus K M Properties, Inc. DBA Maykus Custom H (817) 329-3111 COLLABORATORS •Eason Maykus Maykus Homes (817) 329-3111 •Eason Maykus Kosse Maykus K M Properties, Inc. DBA Maykus Custom H (817) 329-3111 OWNERS •Lonesome Dove Llc Ferguson INSPECTIONS 13 1. Building Tree Inspection 2. Building Setback 3. Building Foundation/Footing 4. Building Pier 5. Building Framing 6. Building Bracing / Sheathing 7. Building Wall Tie Inspection 8. Building Drive Approach 9. Sidewalk Inspection 10. Building Termite Verification 11. Building Energy Code 12. Lot Drainage Inspection 13. Building Final INFORMATION FIELDS **APPLICANT NAME (Individual)Eric Schwarze **APPLICANT PHONE NUMBER 817-2293-590 APPLICANT E-MAIL VALUATION 787930 Square Footage 4761 * CONSTRUCTION TYPE VB * OCCUPANCY GROUP R-3 DOCUMENT - LOT DRAINAGE PLOT PLAN (CITY STAFF USE ONLY)25-002313 LOT DRAINAGE REVIEW.pdf DOCUMENTS - MISC 01 3405 witt BUILDING PERMIT APPLICATION1.pdf DOCUMENTS - MISC 02 Grading and Drainage plan.pdf DOCUMENTS - MISC 03 3405 construction docs.pdf DOCUMENTS - MISC 04 3405 Witt - 18-SP1.3.pdf, 3405 Witt - 18- SP1.2.pdf, 3405 Witt - 18-SP1.1.pdf * ZONING DISTRICT R-7.5 APPROVED TO ISSUE ELECTRIC YES APPROVED TO ISSUE MECHANICAL YES APPROVED TO ISSUE PLUMBING YES SETBACK: LEFT 6 SETBACK: FRONT 30 City of Grapevine PO Box 95104 Grapevine, Texas 76099 817) 410-3166 Building - Single Family Residence Project # 25-002313 Project Description: Construct New Single Family Residence [ELECTRONIC REVIEW] Issued on: 07/31/2025 at 1:38 PM MYGOV.US 25-002313, 07/31/2025 at 1:38 PM Issued by: Courtney Cogburn Page 1/3 SETBACK: REAR 25 SETBACK: RIGHT 6 WATER DEPT. LOT DRAINAGE FEE 150 INFORMATION FIELDS FEE TOTAL PAID DUE **Building Permit Fee, R-3 (New Construction) SF $ 2,618.55 $ 2,618.55 $ 2,618.55 Residential Lot Drainage Fee $ 150.00 $ 150.00 $ 150.00 TOTALS $ 2,768.55 $ 2,768.55 $ 0.00 READ AND SIGN I HEREBY CERTIFY THAT THE FOREGOING IS CORRECT TO THE BEST OF MY KNOWLEDGE AND ALL WORK WILL BE PERFORMED ACCORDING TO THE DOCUMENTS APPROVED BY THE BUILDING DEPARTMENT AND IN COMPLIANCE WITH THE CITY OF GRAPEVINE ORDINANCE REGULATING CONSTRUCTION. IT IS UNDERSTOOD THAT THE ISSUANCE OF THIS PERMIT DOES NOT GRANT OR AUTHORIZE ANY VIOLATION OF ANY CODE OR ORDINANCE OF THE CITY OF GRAPEVINE. I FURTHERMORE UNDERSTAND THAT PLANS AND SPECIFICATIONS ARE NOT REVIEWED FOR HANDICAPPED ACCESSIBILITY BY THE CITY AND THAT THE DESIGN PROFESSIONAL / OWNER IS RESPONSIBLE FOR OBTAINING SUCH APPROVAL FROM THE APPROPRIATE STATE AND OR FEDERAL AGENCY(S). July 31, 2025 Signature Date City of Grapevine Building - Single Family Residence Project # 25-002313 NOTICES 1) ALL work must be done in compliance with the 2021 INTERNATIONAL BUILDING CODE. ** ALL work ISSUED prior to January 1, 2024, must be done in compliance with the 2006 INTERNATIONAL BUILDING CODE. 2) City Approved Stamped Plans must be on-site for ALL INSPECTIONS. 3) Project address must be clearly posted at the job site. NOTES MYGOV.US 25-002313, 07/31/2025 at 1:38 PM Issued by: Courtney Cogburn Page 2/3 RECEIVED: 6�t7�2025 DATE OF ISSUANCE-iJ jj 7Il. 25-002313 3405 WITT COURT PERMIT #: 25-002313 NEW SINGLE FAMILY RESIDENCE iW 1 L D EN U 11I: KMIT APPLICATION 1 ELECTRONIC REVIEW (PLEASE PRINT LEGIBLY — COMPLETE ENTIRE FORM) JOB ADDRESS: 3405 Witt Court LOT: 8 BLOCK: 1 SUBDIVISION: Furgeson Place BUILDING CONTRACTOR (company name): Maykus Homes CURRENT MAILING ADDRESS: PO BOX 92747 CITY/STATE/ZIP: Southlake TX 76092 PROPERTY OWNER: Maykus Homes CURRENT MAILING ADDRESS: PO BOX 92742 CITY/STATE/ZIP: Southlake TX 76092 PROJECT VALUE: $ 787930 SUITE # PH: # 817-329-3111 Fax # PHONE NUMBER: 817-329-3111 FIRE SPRINKLERED? YES NO X WHAT TRADES WILL BE NEEDED? (check ones that apply) ELECTRIC X PLUMBING X MECHANICAL X DESCRIPTION OF WORK TO BE DONE: construction of a new single family home USE OF BUILDING OR STRUCTURE: single family residence NAME OF BUSINESS: Total Square Footage under roof: 4761 Square Footage of alteration/addition: Ek I hereby certify that plans have been reviewed and the building will be inspected by a certified energy code inspector in accordance with State Law. Plan review and inspection documentation shall be made available to the Building Department (required for new buildings, alterations and additions) ❑ I hereby certify that plans have been submitted to the Texas Department of Licensing and Regulation for Accessibility Review. Control Number: (Not required for I & 2 family dwellings) ❑ I hereby certify that an asbestos survey has been conducted for this structure in accordance with the regulatory requirements of the Texas Department of Health. (REQUIRED FOR DEMOLITIONS, ADDITIONS AND OR ALTERATION TO COMMERCIAL AND PUBLIC BUILDINGS) I hereby certify that the foregoing is correct to the best of my knowledge and all work will be performed according to the documents approved by the Building Department and in compliance with the City Of Grapevine Ordinance regulating construction. It is understood that the issuance of this permit does not grant or authorize any violation of any code or ordinance of the City Of Grapevine. I FURTHERMORE UNDERSTAND THAT PLANS AND SPECIFICATIONS ARE NOT REVIEWED FOR HANDICAPPED ACCESSIBILITY BY THE CITY, AND THAT THE DESIGN PROFESSIONAL/OWNER IS RESPONSIBLE FOR OBTAINING SUCH APPROVAL FROM THE APPROPRIATE STATE AND OR FEDERAL AGENCY(S). PRINT NAME: Eric Schwarze SIGNATURE rzG 'Sc4aaAl PHONE* 817-229-3590 EMAIL: ❑ CHECK BOX IF PREFERRED TO BE CONTACTED BY E-MAIL THE FOLLOWING IS TO BE COMPLETED BY THE BUILDING INSPECTION DEPARTMENT Construction Type: VB I Permit Valuation: $ Setbacks Approval to Issu Occupancy Grout): - 3 Fire Sprinkler: YES NO I Front: ?0 I Electrical I Y f � Division: I Building Depth: Left: (P Plumbing Zoning: le` Bilding Width: I Rear: 7,� Mechanical Occupancy Load: I �/ , Grease Trap Ri,,ht: & Hood 41 �� Plan Review Approval: >roval: Date: , - �3' Building Permit Fee: 2,618.55 Site Plan Approval: Date: Plan Review Fee: Fire Department: Date: Lot Drainage Fee: 150.00 0 Public Works Department: Date: Sewer Availability Rate: 845.00, co 00 Health Department: Date: Water Availability Rate: 1,543.00 *" Approved for Permit: Date: Total Fees: Lot Drainage Submitted: Approved: Total Amount Due: 2,768.55 �11104,316,2) P.O. BOX 95104, GRAPEVINE, TX76099(817) 410-3165 I TAP FEES: SEWER, 40.00, WATER, 150.00 O:FORMF\DSPERMITAPPLICATIONS I/02-Rev 11/09,4/11,2119 ge.or ywoe ;sw.t fes IN E PER PLAT ,513D [Lit \r 1G. PA VE1� WALK I I I No BGZFT-) y1 I -.fat-:.:•.� ,_— DRIVE ACH C2@3660,FT� �TG 3405 LUITT GOURT. ED SaF CONSTRUCTION STARTS. 1, EROSION CONTROL REQUt .. 2. NO CONSTRUCTIONS FIk.�-fNO1 CUTTING, OR GRADE CHANGE IN EASEMENT WITHOUT RA DRAINAGE PATTERN. 3. MAINTAIN CURRENT 4. GRASSIEROSION CONTROL REQUIRED BEFORE FINAL. NSF A AUSTIN 13801 Avenue K Austin, TX 78728 p. (512) 251-1044 f. (512) 251-0681 BELTON/TEMPLE 2016 S. Highway Blvd. Belton, TX 76513 p. (254) 939-0888 f. (254) 939-0823 SAN ANTONIO 464 Rodeo Drive Spring Branch, TX 78070 p. (210) 657-2741 f. (210) 657-4764 DALLAS/FT. WORTH 4329 Clay Ave Haltom City, TX 76117 p. (817) 577-9444 f. (817) 577-9949 March 18, 2025 Maykus Custom Homes P.O. Box 92747 Southlake, TX 76092 Re: 3405 Witt Court (Lot 8/Block 1) Ferguson Place Grapevine, TX To Whom it May Concern: The foundation for the above referenced project was designed using current engineering practices and site-specific geotechnical data. The design complies with recommendations set forth by the Post-Tensioning Institute (PTI) 3rd Edition and/or specifications stated in the 2021 International Residential Code. Geotechnical information used for the design is as follows: Geotechnical Lab: EWI Report #: HC226957R Report Date: 01/23 Allowable Bearing Capacity: 1500 PSF Please contact us if you have any questions. Sincerely, Alan Golightly, PE F-4031 Foundation Maintenance and Care for Homeowners Your new home has been constructed using a concrete slab-on-grade foundation. This is the most used type of foundation system in Texas. This type of foundation can be reinforced with conven tional mild steel reinforcing, post- tensioned tendons, or a combination of the two. Most builders in the area use post- tensioning, along with some conventional reinforcing. All slab-on-grade foundations are designed to sit on top of the ground and float or flex with movement in the bearing soils. The foundations are built with a certain amount of rigidity; however, they are allowed by normal design parameters to deflect and bend a certain amount. Typically, foundation movements are caused by some change in the bearing soils beneath and directly surrounding the house. The most critical "changeable" factor in the sub-grade soils is the moisture content. This is important because most of the clay soils in the Central Texas area are "active", that is, they ha ve an electromagnetic attraction for water and swell or heave upward when they can absorb water. On the other hand, these clays shrink and subside when they become dry. Thus, it is said that to stabilize and control the movement of clay soils, it is necessary to control their access to water. If the moisture content under the foundation is maintained in a stable condition, the foundation itself will tend to be more stable, and deflection or crac king in the walls of the home should be minimized. When a home is constructed, the moisture content of the soil beneath the foundation is fairly uniform and evenly distributed. The slab foundation acts as a lid or covering, and protects and stabilizes it, except at the edges. Around the edges, swellin g or subsidence can take place, depending upon environmental influences. If the soil outside the foundation along the perimeter is not well - drained, rainwater, sprinkler water or other irrigation water may puddle and slowly saturate the adjacent soil under the foun dation. The saturated soil will swell and heave upward, causing "edge lift". On the other hand, if watering is neglected, and the soil is exposed to summer sun and hot breezes, the soil will dry out, shrink, crack visibly, and subside, causing "edge drop" or "cen ter lift". Either of these conditions may progress to the point where the foundation of the home is deflected, and the frame structure above is distorted and develops severe cracking. It is important that as a homeowner you realize that your foundation is more than just inert, passive concrete and steel. It is an element that will respond to changing conditions, and it needs understanding and maintenance if it is going to give satisfact ory service. The following are several recommended procedures, which will be helpful in this regard: 1) Be certain that the yard around the house slopes away from the foundation. Any standing or ponding water next to the foundation can cause undue unnecessary soil and foundation movement. Be sure the builder has sloped the yar d for good drainage and that all drainage swales are working. A 5% slope is now recommended by the International Residential Code. (5% equals a 6-inch drop in 10 feet) 2) Even and consistent watering should be performed regularly and increased during dry or "drought" periods. Watering should be done around all sides of the home. If a sprinkler system is installed, it should water the entire perimeter. Zoning the system is recommended where over-saturation might otherwise occur along various portions of the ho me. During dry periods and if it is intended to water only the foundation, a soaker hose laid approximately 18" from the foundation can be allowed to drip moisture slowly into the soils several hours a week. This procedure has been used successfully. (How much water is enough? The answer is that soil should be damp to the touch and should be able to be squeezed into a ball, which will retain its shape. If the soil is hard or dusty or cracked, it is too dry. If it is saturated or "squishy", it is too wet.) 3) Trees and shrubs can absorb large quantities of water and their root systems can undermine your foundation. It is typically recommended that new trees be planted more than 1/2 the canopy width of the mature tree away from the foundation, but no closer than 20 feet. Existing trees adjacent to the foundation should be removed. The large r the tree, the greater the threat. Deep planter beds filled with absorbent planter mix soils should not be placed adjacent to the foundation. 4) It is recommended that you check for leaky hose bibs and air conditioner condensation drainpipes which could induce localized water into the sub-grade. 5) Gutters can typically be used to help prevent roof -run-off from dumping concentrated quantities of water into the ground at re - entrant areas and roof valley locations. Homes with gutters should have downspout exten sions and splash blocks and the systems should be cleaned regularly. The splash blocks should not direct the flow into planter beds. 6) Be aware that alterations and improvements such as new landscaping, addition, pools, decks, sidewalks, etc., can change the drainage patterns of your home and could induce problems if area drainage is not properly addressed. Note changes in surrounding of adjacent lots since additional water could be directed at your residence. EX U R B S T U D I O ww w . E X U R B S T U D I O . c O m POOL 37 ' - 8 " 11 ' - 0 " 4' - 1 " 20 ' - 5 " 73 ' - 2 " 4' - 2 " 48 ' - 0 " 4' - 0 " 1' - 7 " 15 ' - 5 " 73 ' - 2 " 36'-8"16'-0"1'-4" 54'-0" 3'-2"13'-9"21'-1"15'-1"11" 54'-0" 6"10 SP @ 3'-912" = 38'-0"4 SP @ 3'-614" = 14'-1"6" 6" 4 S P @ 3 ' - 1 0 14" = 1 5 ' - 5 " 4' - 0 " 12 S P @ 4 ' - 0 12" = 4 8 ' - 7 " 4' - 2 " 6" DEAD END FOR BEAM STRAND ONLY. MID BEAM 2-#5's T&B 2-#5's T&B 2-#5's T&B 2-#5's T&B SL O P E SL O P E SL O P E 10'-0" 4' - 2 " 11 ' - 0 14" 10 ' - 6 14" 10 ' - 6 14" 10 ' - 6 1 4" 10 ' - 6 14" 7' - 8 12" 8' - 2 12" 10'-10"10'-4"10'-4"10'-4"10'-10" / C1 S1 . 0 / C2 S 1 . 0 / C2 S1 . 0 / 2 S2 . 0 / 2 S2 . 0 / 2 S2 . 0 / 4 S2 . 0 /3 S2.0 /3 S2.0 /1 S2.0 /C2 S1.0 /2 S2.0 /2 S2.0 (TYP.) INT. BEAM. 10" 17' 18' 55' 50 ' 76 ' 52' 55' 55' 55' 56' 54 ' 56 ' 56 ' 75 ' 75 ' 75 ' 75 ' 75 ' / 1 8 ' 56 ' 56 ' 56 ' 56 ' 56 ' 54 ' 54 ' 54 ' 54 ' 17' 17' 17' 52' 55' 56' 56' 55' 55' 55' 55' 55' 55' 55' 55' 2-#4 SHEAR BARS. (TYP.) (W) BEAM WIDTH REF. PLAN 4" VAPOR BARRIER 3' - 0 " M I N . NOTE: CONTINUE POOL BARRIER FOR 10' . (ALL SIDES) SCALE: 3/4" = 1'-0"C2 POOL BARRIER DETAIL (TO BE USED FOR POOLS WITHIN 10'-0" OF FOUNDATION) VAPOR BARRIER (W) BEAM WIDTH REF. PLAN 4" VAPOR BARRIER 3' - 0 " M I N . SCALE: 3/4" = 1'-0"C1 POOL BARRIER DETAIL (TO BE USED FOR POOLS WITHIN 10'-0" OF FOUNDATION) VAPOR BARRIER 512" 112" NOTE: CONTINUE POOL BARRIER FOR 10' . (ALL SIDES) SLAB TENDON 5" t o 6 " SLAB TENDON 5" t o 6 " 2 #5(s) BOTTOM SLAB TENDON ONE OR TWO BEAM TENDONS REF. PLAN 2 #5(s) BOTTOM SLAB TENDON ONE OR TWO BEAM TENDONS REF. PLAN DRAWN BY: JOB NUMBER: DATE SHEET REVISION NOTES SCALE BEAM NOTE CONCRETE INFO FOUNDATION PLAN TX FIRM REG. NO. F-4031WWW.CRITEXAS.COM = 1 BEAM TENDON, NO SLAB TENDON = 2 BEAM TENDON, 1 SLAB TENDON = 2 BEAM TENDON, NO SLAB TENDON = 1 BEAM TENDON, 1 SLAB TENDON (817) 577-9444 CO N T A C T C R I F O R PT I C E R T I F I E D M A T E R I A L 81 7 - 5 7 7 - 9 4 4 4 DF W M A T E R A I L S @ C R I T E X A S . C O M S1.0 03/17/25 34 0 5 W I T T C O U R T MA Y K U S H O M E S & N E I G H B O R H O O D S 10" 26" 26" GeoT:Report No. Date: Em(Cntr)Ym(Cntr)Em(Edge) Brg. Cap.= Ym(Edge) Ed.psf 3rd EWI HC226957R 01/23 1500 7.4 4.4 1.3 1.9 NOTE: THE CONTRACTOR SHALL VERIFY ALL DROPS, DIMENSIONS, AND BRICK LEDGES. (DO NOT SET FORMS OFF OF FOUNDATION PLAN.) ANY DROPS ADJUSTED IN THE FIELD TO AN OVERALL HEIGHT GREATER THAN 18" WILL REQUIRE REVISED PLANS. SEE BEAM NOTES ON PAGE ONE FOR BEAM DEPTH & ANY ADDITIONAL BEAM REINFORCEMENT. NOTES AND SPECIFICATIONS DESIGN 1.This design is based on acceptable engineering practices per requirements of PTI, BRAB report #33 WRI, IRC and ACI 318 and appropriate soil reports. 2.The design shown is applicable for this specific location. Use of this design for other locations is prohibited. 3.Beam sizes shown on drawings are minimums. 4.Live loads per IRC. Dead loads per building material weights. MATERIALS 1.All concrete to be normal weight Type I or II with a compressive strength of 3000 psi at 28 days. Additives with calcium chloride are prohibited. 2.All post-tensioned tendons to be ½ inch 270 ksi unbonded strand. 3.All non-prestressed reinforcing to be ASTM 615 Gr 60 except #3 bars may be Gr 40. 4.Vapor barrier to be minimum of 6 mil, unless governing jurisdiction directs otherwise. Contractor is responsible for required vapor barrier thickness. 5.Waterproofing for walls below grade to be miradrain 6000/6200 or approved equal 6.In form fill to be TX DOT road base or crusher fines. CONSTRUCTION 1.Remove all vegetation and top 6 inches of top soil prior to constructing foundation. 2.In form fill does not need to be compacted. 3.Drainage around the perimeter of the foundation shall be done per IRC such that no water shall collect under or adjacent to the slab. 4.All downspouts and A/C overflow outlets should be directed away from the foundation or connected to an underground drainage system. 5.Heavy vegetation such as trees within 10 ft. of foundation may cause excessive water removal and possible damage to foundations. No trees should be planted within 10 ft or the mature height of the tree planted. 6.Unless directed by the Geotechnical report or otherwise noted on the plans, exterior beams to be a minimum of 12 inches into undisturbed soil or compacted select fill. When conditions prohibit this depth, contact the Engineer of record. 7.Provide a vapor barrier under the slab, drape vapor barrier down beam sides a minimum of 6 inches, adjacent sheets shall be overlapped 6 inches and pinned or sealed. 8.Additional beam reinforcing required for beams over 48 inches deep. See Deep beam reinforcing details. 9.For field conditions not explicitly covered by plans and details, contact Engineer of Record. 10.Adequately support tendons and rebar. 11.Stress tendons at concrete strength of 2000 psi or at 7 to 10 days. 12.Properly consolidate concrete especially around anchors with vibrators. 13.Do not set forms by the foundation plans, use architectural plans. 14.Contractor to verify all drops, dimensions, and brick ledges. 15.Exterior beam depths change with topography, see details. 16.Report all conflicts to the Engineer of record. 17.For PI of less than 15 or solid rock, notify Engineer of record 18.Waterproofing on walls below grade that enclose interior spaces shall extend from bottom of the footing to finished grade. All joints shall be lapped and sealed per manuf. requirements. 19.Cold weather concreting shall meet to requirements of ACI 305 and hot weather concreting shall meet the requirements of ACI 305 20.Pre-pour inspections of slabs are valid for one week only. FILL MATERIAL All foundations built in compacted fill material in areas of expansive clays shall comply with the requirements of the report of the geotechnical firm of record or the following. 1.Maximum PI of material passing the No. 4 sieve shall not exceed 35 2.The material shall have at least 50 percent passing the No. 4 sieve 3.Minimum PI of 3 4.Minimum and maximum passing #200 sieve: 10% to 70% 5.No stones larger than 3 inches 6.Lifts shall not exceed 8 inches prior to compaction 7.Each lift should be compacted to 95 percent of maximum laboratory density per ASTM D998 8.Fill shall be within 4 percentage points of optimum moisture content during compaction 9.Each lift shall be inspected and tested for density compliance by a qualified geotechnical firm under the supervision of a geotechnical engineer prior to placing the next lift. 10.Not less than one field density test per 2500 square feet or a minimum of 3 per lift is required 11.Fill to extend 3 foot outside foundation prior to sloping at 1:6 to natural grade 512" 112" (W) BEAM WIDTH REF. PLAN 4" SLAB TENDON 5" t o 6 " 6" SLAB TENDON ONE OR TWO BEAM TENDONS REF. PLAN (D ) BE A M D E P T H RE F P L A N 12 " M I N . E M B E D M E N T IN T O N A T U R A L G R A D E OR C O M P A C T E D F I L L VAPOR BARRIER SCALE: 3/4" = 1'-0"1 EXTERIOR BEAM WITH BRICK LEDGE (W) BEAM WIDTH REF. PLAN 4" SLAB TENDON 5" t o 6 " 6" SLAB TENDON ONE OR TWO BEAM TENDONS REF. PLAN (D ) BE A M D E P T H RE F P L A N SLOPE EXTERIOR GRADE AWAY FROM BUILDING, TYP. 12 " M I N . E M B E D M E N T IN T O N A T U R A L G R A D E OR C O M P A C T E D F I L L VAPOR BARRIER SCALE: 3/4" = 1'-0"2 EXTERIOR BEAM WITHOUT BRICK LEDGE 512" 112" (W) BEAM WIDTH REF. PLAN 4" SLAB TENDON 5" t o 6 " 6" SLAB TENDON ONE OR TWO BEAM TENDONS REF. PLAN (D ) BE A M D E P T H RE F P L A N SLOPE EXTERIOR GRADE AWAY FROM BUILDING, TYP. 12 " M I N . E M B E D M E N T IN T O N A T U R A L G R A D E OR C O M P A C T E D F I L L VAPOR BARRIER SCALE: 3/4" = 1'-0"3 EXTERIOR BEAM WITH BRICK LEDGE & CURB 6" M A X . VA R I E S 112" (W) BEAM WIDTH REF. PLAN 4" SLAB TENDON 5" t o 6 " 6" SLAB TENDON ONE OR TWO BEAM TENDONS REF. PLAN (D ) BE A M D E P T H RE F P L A N VAPOR BARRIER SCALE: 3/4" = 1'-0"4 EXTERIOR BEAM AT GARAGE ENTRY (W) BEAM WIDTH REF. PLAN 4" SLAB TENDON 5" t o 6 " 6" SLAB TENDON ONE OR TWO BEAM TENDONS REF. PLAN (D ) BE A M D E P T H RE F P L A N SLOPE EXTERIOR GRADE AWAY FROM BUILDING, TYP. 12 " M I N . E M B E D M E N T IN T O N A T U R A L G R A D E OR C O M P A C T E D F I L L VAPOR BARRIER SCALE: 3/4" = 1'-0"5 EXTERIOR BEAM WITH CURB 6" M A X VA R I E S 512" 112" (W) BEAM WIDTH REF. PLAN 4" SLAB TENDON 5" t o 6 " (D ) BE A M D E P T H RE F P L A N SLOPE EXTERIOR GRADE AWAY FROM BUILDING, TYP. 12 " M I N . E M B E D M E N T IN T O N A T U R A L G R A D E OR C O M P A C T E D F I L L VAPOR BARRIER SCALE: 3/4" = 1'-0"6 EXTERIOR BEAM WITH BRICK LEDGE 3" C L R . TY P . #3 @ 24" O.C. 2-#5's TOP CONT. 2-#5's BOTT. CONT. (W) BEAM WIDTH REF. PLAN 4" SLAB TENDON 5" t o 6 " (D ) BE A M D E P T H RE F P L A N SLOPE EXTERIOR GRADE AWAY FROM BUILDING, TYP. 12 " M I N . E M B E D M E N T IN T O N A T U R A L G R A D E OR C O M P A C T E D F I L L VAPOR BARRIER SCALE: 3/4" = 1'-0"7 EXTERIOR BEAM WITHOUT BRICK LEDGE 3" C L R . TY P . #3 @ 24" O.C. 2-#5's TOP CONT. 2-#5's BOTT. CONT. SCALE: 3/4" = 1'-0"8 TYPICAL INTERIOR BEAM (W) BEAM WIDTH REF. PLAN 4" SLAB TENDON 6" SLAB TENDON ONE OR TWO BEAM TENDONS REF. PLAN (D ) BE A M D E P T H RE F P L A N VAPOR BARRIER THE CONTRACTOR SHALL VERIFY ALL DROPS, DIMENSIONS, AND BRICK LEDGES. (DO NOT SET FORMS OFF OF FOUNDATION PLAN.) 512" 112" (W) BEAM WIDTH REF. PLAN 4" SLAB TENDON 5" t o 6 " 6" SLAB TENDON ONE OR TWO BEAM TENDONS REF. PLAN (D ) BE A M D E P T H RE F P L A N SLOPE EXTERIOR GRADE AWAY FROM BUILDING, TYP. 12 " M I N . E M B E D M E N T IN T O N A T U R A L G R A D E OR C O M P A C T E D F I L L VAPOR BARRIER 6" T O 4 ' - 6 " #4 @ 12" O.C. VERT. #4 @ 12" O.C. HORIZ. SCALE: 3/4" = 1'-0"9 STEM WALL WITH BRICK LEDGE EXTERIOR BEAM SLOPE EXTERIOR GRADE AWAY FROM BUILDING, TYP. FILL DRAWN BY: DETAIL INFO: TX FIRM REG. NO. F-4031 WWW.CRITEXAS.COM DATE SHEET REVISION NOTES SCALE 06/17/24 S2.0 DE T A I L S H E E T T Y P I C A L P O S T - T E N S I O N SCALE: 3/4" = 1'-0"11 DRAPED BEAM DETAIL (W) BEAM WIDTH REF. PLAN 10 " 6" M E A S U R E D F R O M SC H E D U L E D ( D E S I G N ) D E P T H SLAB TENDON ONE OR TWO BEAM TENDONS REF. PLAN (D ) BE A M D E P T H RE F P L A N (W) BEAM WIDTH REF. PLAN SLAB TENDON SCALE: 3/4" = 1'-0"10 INTERIOR DROP UP TO 18" 4" 112" T O 1 8 " PROVIDE #4's @ 18" O.C. IF DROP EXCEEDS 8" NO BEAM REQUIRED PROVIDE #4 CONT. IF DROP EXCEEDS 8" SCALE: 3/4" = 1'-0"13 INTERIOR DROP OVER 18" 24" 24" 5" T O 6 " 18 " T O 4 8 " 4" SLAB TENDON BEAM TENDON BEAM TENDON SLAB TENDON #4's CONT. (TYP.) #4's CONT. (TYP.) SLAB TENDON #4 "Z" BARS @ 18" O.C. BEAM IS REQUIRED (D ) BE A M D E P T H RE F P L A N VAPOR BARRIER DE P T H ( S E E A R C H . ) 48 " T O 1 0 ' - 0 " M A X . CONTINUOUS GRAVEL POCKET: 12"x12" WATERPROOF BELOW GRADE PER 2015 IRC R406.2 4" PERFORATED DRAIN TO DAYLIGHT. MINIMUM SLOPE: 14"/ FT WRAP IN FILTER CLOTH. BEAM TENDON OR REBAR PER PLAN SLAB TENDON 4" SLAB 1/2" JOINT SEALANT TOP TENDON #4 @ 12" O.C. HORIZ. #5 @ 16" O.C. VERT. 26 " CONSTR. JOINT W/WATER STOP 10" PROFILE OF BEAM BEYOND FILL VAPOR BARRIER FILL (D ) BE A M D E P T H RE F P L A N SCALE: 3/4" = 1'-0"12 WITH DROP BRICK LEDGE EXTERIOR BEAM UP TO 4'-0" SCALE: 3/4" = 1'-0"14 DETAIL @ 48" TO 10' DROPPED SLAB SCALE: 3/4" = 1'-0"15 EXTERIOR DEEP BEAM REINFORCING DETAIL (W) BEAM WIDTH REF. PLAN (W) BEAM WIDTH REF. PLAN CONTINUOUS GRAVEL POCKET: 12"X12" MIRA DRAIN 6000/6200 OR APPROVED EQUAL INSTALL PER MANUF. REQUIREMENTS 4" PERFORATED DRAIN TO DAYLIGHT. MINIMUM SLOPE: 14"/ FT WRAP IN FILTER CLOTH. PROFILE OF SLAB BEYOND DEEP BEAM REINFORCING CHART WALL HEIGHT ("W") WALL THICKNESS BARS (A) BARS (B) EMBEDMENT (E) SOIL / ROCK >6' TO 9' * >9' TO 12' * >12' TO 15' >15' TO 18' 12" 12" 12" 12" 15" #4 @ 12" #5 @ 16" #5 @ 12" #6 @ 12" 1' 1' 1'6" 6" 6" 6" 6" >4' TO 6' * 2' 2' #4 @ 16"#4 @ 16" #4 @ 12" #5 @ 16" #5 @ 16" #4 @ 12" NOTE: DRAIN MAY BE OMITTED IF DROP IS LESS THAN 24" REINFORCEMENT: PER DESIGN ADDITIONAL REINFORCEMENT: 2-#5 T&B W/ #3 STIRRUPS @ 18" O.C. (W) BEAM WIDTH REF. PLAN 4" VAPOR BARRIER 1' - 0 " B E L O W LO W E S T R O O T OR 2 ' - 0 " B E L O W RE Q ' D E M B E D , WH I C H E V E R I S GR E A T E R TREE NOTE: CONTINUE ROOT BARRIER FOR 10' FROM CENTERLINE OF TREE (BOTH SIDES) SCALE: 3/4" = 1'-0"16 BEAM ROOT BARRIER DETAIL 5'-0" (MIN.) (TO BE USED FOR TREES WITHIN 20'-0" OF FOUNDATION) 512" (W) BEAM WIDTH REF. PLAN 4" SLAB TENDON 5" t o 6 " SLAB TENDON ONE OR TWO BEAM TENDONS REF. PLAN VAPOR BARRIER 512" VA R I E S 18 " M I N . 6' - 0 " ( M A X . ) SLOPE EXTERIOR GRADE AWAY FROM BUILDING, TYP. 12 " M I N . E M B E D M E N T IN T O N A T U R A L G R A D E OR C O M P A C T E D F I L L SLAB TENDON OPTIONAL CONSTR. JOINT W/WATER STOP WA L L H T . (E ) EM B E D M E N T 5" T O 6 " ONE OR TWO BEAM TENDONS REF. PLAN (W) BEAM WIDTH REF. CHART BAR (A) BAR (B) SLAB TENDON 4" VAPOR BARRIER SLOPE EXTERIOR GRADE AWAY FROM BUILDING, TYP. 512" MASONRY VENEER REF. ARCH'L MAX HEIGHT OF VENEER SUPPORTED BY FOUNDATION = 30'-0" MASONRY LEDGE WHERE REQ'D MIN. 18" DEEP 2-#3's CONT. #3 CORNER BAR @ 36" O.C. 2-#4's CONT. #4 CORNER BAR @ 36" O.C. 6" M I N . BAR (B) BAR (A) BE A M D E P T H MIN. VERTICAL BAR LAP SPLICE =30" GRADE LEVEL 4' - 0 " BRICK LEDGE 3" 512" MI N . 3 0 " L A P DRAWN BY: DETAIL INFO: TX FIRM REG. NO. F-4031 WWW.CRITEXAS.COM DATE SHEET REVISION NOTES SCALE 06/17/24 S2.1 DE T A I L S H E E T T Y P I C A L P O S T - T E N S I O N 23'-0"13'-3"16'-0"1'-4" 3'-2"13'-4"9'-8"26'-1"1'-4" 37 ' - 8 " 11 ' - 0 " 4' - 1 " 5' - 0 " 4' - 7 " 47 ' - 2 " 4' - 0 " 2' - 0 " 53'-7" 57 ' - 9 " 57 ' - 9 " 53'-7" CS-WSP CS-WSP CS-WSP CS-WSP CS-WSP CS-WSP CS - W S P CS - W S P CS - W S P CS - W S P CS - W S P CS - W S P CS - W S P BWL A BWL A BWL 1BWL 1 BWL C BWL C BWL 3BWL 3 BWL A BWL A 4' - 1 " 5' - 8 " OS B (1 S I D E ) OS B ( 1 S I D E ) 22'-4"27'-11"1'-4" 2' - 3 " 2' - 3 " 22'-4"27'-11"1'-4" 5'-0" 4'-0"5'-6"BWL 2BWL 2 27 ' - 6 " 24 ' - 0 " 27 ' - 6 " 24 ' - 0 " 4' - 0 " **** 30"30" EXTENT OF HEADER OSB (1 SIDE) OSB (1 SIDE) OSB (1 SIDE) 2'-0" 2'-0" 3'-3" * REF. DETAIL 4/S4.0 FOR HOLD DOWN INFO. PFH (TWO SIDED) 39" REQUIRED FOR BWP. EXTEND SHEATHING TO INSIDE AS SHOWN DTT1Z HOLD-DOWN DRAWN BY: JOB NUMBER: TX FIRM REG. NO. F-4031 WWW.CRITEXAS.COM DATE SHEET REVISION NOTES SCALE THIS DESIGN MEETS OR EXCEEDS REQUIREMENTS OF PRESCRIPTIVE METHOD FOR WIND BRACING DESIGN PER R602.10 OF ADOPTED CODE. WHERE STRUCTURAL ELEMENTS EXCEEDS THE LIMIT OF THIS METHOD, ENGINEERED DESIGN HAS BEEN APPLIED PER SECTION R301.1.3 OF ADOPTED CODE. NOTES WIND BRACING PLAN THESE PLANS AND SPECIFICATIONS ARE THE SOLE PROPERTY OF CRI AND MAY ONLY BE USED ONCE FOR THE SINGLE SITE OR LOT LOCATION FOR WHICH THEY ARE PREPARED. NO OWNERSHIP RIGHTS ARE CONVEYED FOR THE FUTURE USE OF THESE PLANS. THE REPRODUCTION OR REUSE OF THESE PLANS AND SPECIFICATIONS AT ANY OTHER LOCATION OR FOR ANY OTHER PURPOSE IS STRICTLY PROHIBITED. S3.0 NOTES: 1.WIND LOADS PER 2021 INTERNATIONAL RESIDENTIAL CODE: ULTIMATE WIND SPEED: 115 MPH (3 SEC. GUST) EXPOSURE: B BUILDING CATEGORY II I = 1.0 2.SHEATHING TO BE 716" STRUCTURAL PLYWOOD OR OSB. ATTACH WITH/ FASTENERS 6" O.C. @ EDGES AND 12" O.C. INTERMEDIATE STUDS. PER ADOPTED IRC. TABLE R602.3 (1). 2x STUDS AT 16" O.C.. FASTEN STUDS PER ADOPTED IRC. 3.IN LIEU OF NAILS, INTERIOR PANELS MAY BE ATTACHED TO STUDS W/ 16GA x 7 16" CROWN x 13 4" LEG STAPLES @ 3" ON CENTER AT PANEL EDGES AND @ 6" O.C. AT INTERMEDIATE STUDS. THE CROWNS OF THE STAPLES SHALL BE PARALLEL WITH THE LONG DIMENSION OF THE FRAMING MEMBER 4.FASTENERS BETWEEN PANEL ENDS SHALL BE PER ADOPTED IRC. 5.FLOOR DECK SHALL BE 3 4" (MIN.) PLYWOOD OR OSB FASTENED WITH 8D COMMON NAILS @ 6" O.C. (EDGES) AND 12" O.C. (INTERMEDIATE) 6.ROOF DECK SHALL BE 716" (MIN.) PLYWOOD OR OSB FASTENED WITH 8D COMMON NAILS @ 6" O.C. (EDGES) AND 12" O.C. (INTERMEDIATE) 7.ALL GYPSUM SHEATHING SHALL BE 12" THICK, AND FASTENED WITH 112" GALVANIZED ROOFING NAIL; 112" SCREW, TYPE W (REF. TABLE R602.10.4) NAILS/SCREWS @ 7" O.C. SYMBOL DESCRIPTION * [REF. TABLE R602.3(1)] [REF. TABLE R602.10.4] 1/2" 7/16" LEGEND BRACING METHOD (1) THICKNESS (TABLE R602.10.4) FASTENERS (TABLE R602.10.4) NOT USED NOT USED GB PF 7 16" PLYWOOD / OSB SHEATHING WSP: WOOD STRUCTURAL PANEL (2) PFH (3) / PFG (4) / CS-PF (5), REFER PLAN AND DETAIL 11/ 12/ 14 ON SHEET S4.1 CS-SFB: STRUCTURAL FIBER BOARD HOLD DOWN LOCATION REF. DETAIL 4/S4.0 FOR USE, TYPE AND CAPACITY 7 16" PORTAL FRAME (PLYWOOD/OSB) STRUCTURAL GRADE T- PLY (THERMO PLY) NOT USED NOT USED GYPSUM BOARD PORTAL FRAME BRACING METHOD (1) CS-WSP CONT. SHEATHED WOOD STRUCTURAL PANEL 7 16"8d COMMON (2 12" LONG x 0.131" DIA.) NAILS. (1)IRC 2021: R602.10.4 (2)EITHER SIDE OF WALL ON INTERIOR WALLS. NOTED SIDE PREFERRED. (3)PORTAL FRAME (INTERMITTENT) WITH HOLD DOWNS. (4)PORTAL FRAME AT GARAGE. (5)CONTINUOUSLY SHEATHED PORTAL FRAME 03/26/25 34 0 5 W I T T C O U R T MA Y K U S H O M E S & N E I G H B O R H O O D S 9'-0"27'-8"16'-0" 3'-73 4"16'-63 8"16'-53 4"16'-0" 7' - 7 " 2' - 0 " 30 ' - 6 " 4' - 1 0 " 1' - 1 0 3 4" 46 ' - 9 3 4" 52'-8" 52'-8" 46 ' - 9 3 4" CS-WSP CS-WSP CS-WSP CS-WSP CS-WSP CS-WSP CS-WSP CS - W S P CS - W S P CS - W S P * CS - W S P BWL A BWL A BWL 1BWL 1 BWL 2BWL 2 BWL C BWL C 7' - 8 " 4' - 0 " OS B ( 1 S I D E ) OS B (1 S I D E ) BWL B BWL B 36'-11"15'-9" 36'-11"15'-9" 39 ' - 8 " 3' - 4 " 3' - 9 3 4" 3' - 9 3 4" 39 ' - 8 " 3' - 4 " DTT1Z HOLD-DOWN OR LSTA18 ALTERNATIVELY DRAWN BY: JOB NUMBER: TX FIRM REG. NO. F-4031 WWW.CRITEXAS.COM DATE SHEET REVISION NOTES SCALE THIS DESIGN MEETS OR EXCEEDS REQUIREMENTS OF PRESCRIPTIVE METHOD FOR WIND BRACING DESIGN PER R602.10 OF ADOPTED CODE. WHERE STRUCTURAL ELEMENTS EXCEEDS THE LIMIT OF THIS METHOD, ENGINEERED DESIGN HAS BEEN APPLIED PER SECTION R301.1.3 OF ADOPTED CODE. NOTES 2nd FLR. WIND BRACING PLAN THESE PLANS AND SPECIFICATIONS ARE THE SOLE PROPERTY OF CRI AND MAY ONLY BE USED ONCE FOR THE SINGLE SITE OR LOT LOCATION FOR WHICH THEY ARE PREPARED. NO OWNERSHIP RIGHTS ARE CONVEYED FOR THE FUTURE USE OF THESE PLANS. THE REPRODUCTION OR REUSE OF THESE PLANS AND SPECIFICATIONS AT ANY OTHER LOCATION OR FOR ANY OTHER PURPOSE IS STRICTLY PROHIBITED. S3.1 NOTES: 1.WIND LOADS PER 2021 INTERNATIONAL RESIDENTIAL CODE: ULTIMATE WIND SPEED: 115 MPH (3 SEC. GUST) EXPOSURE: B BUILDING CATEGORY II I = 1.0 2.SHEATHING TO BE 716" STRUCTURAL PLYWOOD OR OSB. ATTACH WITH/ FASTENERS 6" O.C. @ EDGES AND 12" O.C. INTERMEDIATE STUDS. PER ADOPTED IRC. TABLE R602.3 (1). 2x STUDS AT 16" O.C.. FASTEN STUDS PER ADOPTED IRC. 3.IN LIEU OF NAILS, INTERIOR PANELS MAY BE ATTACHED TO STUDS W/ 16GA x 7 16" CROWN x 13 4" LEG STAPLES @ 3" ON CENTER AT PANEL EDGES AND @ 6" O.C. AT INTERMEDIATE STUDS. THE CROWNS OF THE STAPLES SHALL BE PARALLEL WITH THE LONG DIMENSION OF THE FRAMING MEMBER 4.FASTENERS BETWEEN PANEL ENDS SHALL BE PER ADOPTED IRC. 5.FLOOR DECK SHALL BE 3 4" (MIN.) PLYWOOD OR OSB FASTENED WITH 8D COMMON NAILS @ 6" O.C. (EDGES) AND 12" O.C. (INTERMEDIATE) 6.ROOF DECK SHALL BE 716" (MIN.) PLYWOOD OR OSB FASTENED WITH 8D COMMON NAILS @ 6" O.C. (EDGES) AND 12" O.C. (INTERMEDIATE) 7.ALL GYPSUM SHEATHING SHALL BE 12" THICK, AND FASTENED WITH 112" GALVANIZED ROOFING NAIL; 112" SCREW, TYPE W (REF. TABLE R602.10.4) NAILS/SCREWS @ 7" O.C. SYMBOL DESCRIPTION * [REF. TABLE R602.3(1)] [REF. TABLE R602.10.4] 1/2" 7/16" LEGEND BRACING METHOD (1) THICKNESS (TABLE R602.10.4) FASTENERS (TABLE R602.10.4) NOT USED NOT USED GB PF 7 16" PLYWOOD / OSB SHEATHING WSP: WOOD STRUCTURAL PANEL (2) PFH (3) / PFG (4) / CS-PF (5), REFER PLAN AND DETAIL 11/ 12/ 14 ON SHEET S4.1 CS-SFB: STRUCTURAL FIBER BOARD HOLD DOWN LOCATION REF. DETAIL 4/S4.0 FOR USE, TYPE AND CAPACITY 7 16" PORTAL FRAME (PLYWOOD/OSB) STRUCTURAL GRADE T- PLY (THERMO PLY) NOT USED NOT USED GYPSUM BOARD PORTAL FRAME BRACING METHOD (1) CS-WSP CONT. SHEATHED WOOD STRUCTURAL PANEL 7 16"8d COMMON (2 12" LONG x 0.131" DIA.) NAILS. (1)IRC 2021: R602.10.4 (2)EITHER SIDE OF WALL ON INTERIOR WALLS. NOTED SIDE PREFERRED. (3)PORTAL FRAME (INTERMITTENT) WITH HOLD DOWNS. (4)PORTAL FRAME AT GARAGE. (5)CONTINUOUSLY SHEATHED PORTAL FRAME 03/26/25 34 0 5 W I T T C O U R T MA Y K U S H O M E S & N E I G H B O R H O O D S ONE STORY WALL PANEL1 T.O. PLATE T.O.C. 716" PLYWOOD (STRUCTURAL I) OR T-PLY SHEATHING EXTERIOR WALL ONLY EN D O F P A N E L T Y P . TWO STORY WALL PANEL2 T.O.C. T.O. PLATE T.O. PLATE EN D O F P A N E L T Y P . EN D O F P A N E L T Y P . 38" FROM SHEATHING EDGE, TYP. PANEL DETAIL5 SHEAR WALL CONNECTION6 SHEAR WALL 2 STORY BEARING WALL CONN.7 TYPICAL NON SHEAR/ AT SHEAR WALL8 DRAG TRUSS TRUSS ALIGNED W/ SHEAR WALL AT SHEAR WALL9 DRAG TRUSS TRUSS ALIGNED W/ SHEAR WALL 2" MIN. 914" MAX. NOTE: DETAIL SHOWS OSB SHEATHING. FOR T-PLY, PANELS WILL OVERLAP CONNECTION WHEN PARALLEL TO FLOOR/CEILING FRAMING BRACED WALL PANEL FRAMING CONNECTION3 PERPENDICULAR FRAMING PERPENDICULAR FRAMING CONNECTION WHEN PERPENDICULAR TO FLOOR/CEILING FRAMING MINIMUM WALL STUD FRAMING NOMINAL SIZE AND GRADE MAXIMUM PONY WALL HEIGHT (feet) MAXIMUM TOTAL WALL HEIGHT (feet) MAXIMUM OPENING WIDTH (feet) TENSION STRAP CAPACITY REQUIRED (pounds)a Ultimate Design Wind Speed Vult (mph) ≤ 110 115 130 ≤ 110 115 130 Exposure B Exposure C 2 x 4 No. 2 Grade 0 10 18 1,000 1,000 1,000 1,000 1,000 1,050 1 10 9 1,000 1,000 1,000 1,000 1,000 1,750 16 1,000 1,025 2,050 2,075 2,500 3,950 18 1,000 1,275 2,375 2,400 2,850 DR 2 10 9 1,000 1,000 1,475 1,500 1,875 3,125 16 1,775 2,175 3,525 3,550 4,125 DR 18 2,075 2,500 3,950 3,975 DR DR 2 12 9 1,150 1,500 2,650 2,675 3,175 DR 16 2,875 3,375 DR DR DR DR 18 3425 3,975 DR DR DR DR 4 12 9 2,275 2,750 DR DR DR DR 12 3,225 3,775 DR DR DR DR 2 x 6 Stud Grade 2 12 9 1,000 1,000 1,700 1,700 2,025 3,050 16 1,825 2,150 3,225 3,225 3,675 DR 18 2,200 2,550 3,725 3,750 DR DR 4 12 9 1,450 1,750 2,700 2,725 3,125 DR 16 2,050 2,400 DR DR DR DR 18 3,350 3,800 DR DR DR DR DR = Design Required a. Straps shall be installed in accordance with manufacturer's recommendations. PORTAL FRAME HEADER STRAP CAPACITY10 DESCRIPTION OF USE HOLD-DOWN CAPACITY REQUIRED HOLD-DOWN TO USE (SIMPSON OR EQUIVALENT)a,b AT PFH PORTAL FRAME (STRAP TYPE HOLD-DOWN)3500 LB STHD14/ STHD14RJ AT PFH PORTAL FRAME (STRAP TYPE HOLD-DOWN)1000 LB LSTHD8 AT END OF BRACED WALL LINE HOLD-DOWN (WHERE REQUIRED) 800 LB DTT1Z AT CS-PF PORTAL FRAME OVER RAISED WOOD FLOOR (FRAMING ANCHOR OPTION) 670 LB LTP4 (LONG DIMENSION HORIZONTAL) OR LSTA18 (STRAP TYPE OPTION) a. Connector shall be installed in accordance with manufacturer's recommendations. b. Hold-Down/ Connectors can be replaced with like or better option if required. HOLD-DOWN SCHEDULE4 REF. SHEAR WALL SCHEDULE (SHT 1 NOTE 2) FOR FASTENER SPACING (INTERIOR) REF. SHEAR WALL SCHEDULE (SHT 1 NOTE 2) FOR FASTENER SPACING (EDGE) HORIZONTAL BLOCKING AT PANEL EDGES (SEE DETAIL 5) 2x SILL PLATE ANCHOR BOLTS MAY SUBSTITUTED WITH X-C PAF (21316" LONG) @ 9" O.C. DBL. PLATEDETAIL 5 2x STUD @ 16" O.C. DETAIL 5 2x SILL PLATE 12"x10" (7" EMBEDMENT) ANCHOR BOLTS @ 6'-0" O.C. MAX. REF. SHEAR WALL SCHEDULE (SHT 1 NOTE 2) FOR FASTENER SPACING (INTERIOR) REF. SHEAR WALL SCHEDULE (SHT 1 NOTE 2) FOR FASTENER SPACING (EDGE) RIM BOARD HORIZONTAL BLOCKING AT PANEL EDGES (SEE DETAIL 5) DBL. PLATE 2x STUD @ 16" O.C. DETAIL 6 2x STUD SHEATHING EDGE REF. SHEAR WALL SCHEDULE (SHT 1 NOTE 2) FOR FASTENER SPACING HORIZ. BLOCKING AT SHEATHING EDGES 2x STUD PLYWOOD FLOOR REF. SHEAR WALL SCHEDULE (SHT 1 NOTE 2) FOR FASTENER SPACING RIM BOARD 2x STUD FLOOR JOIST 2x PLATE TOP PLATE 2-SIMPSON STC CLIPS OR 1-DTC CLIPS EACH SIDE OF 2x4 3-16d NAILS CEILING JOISTS/TRUSSES 2x4 FLAT BLOCKING @ 24" O.C. EA. CLIP BETWEEN ROOF TRUSSES 2x STUD WALL (NO SHEAR/LOAD BEARING) SHEATHING PER GSN PRE-ENGINEERED ROOF TRUSS BY OTHERS 2x4 HORIZONTAL BRACE @ 48" O.C. 2-16d NAILS DRAG TRUSS A35/LTP4 @ 24" O.C. INSTALL AFTER ROOF IS LOADED SHEAR WALL PER PLAN TRUSS OFFEST FROM WALL. CLIP TRUSS TO TOP PLATE W/ LPT4 @ 24" O.C. LPT4 TO BE LAID FLAT AND FASTENED UP INTO BOTTOM OF TRUSS AND DOWN INTO TOP OF PLATE 16d TOE NAIL AT 12" O.C. SHEATHING PER GSN PRE-ENGINEERED ROOF TRUSS BY OTHERS 2x CONT. NAILER 16d NAILS @ 6" O.C. SHEAR WALL PER PLAN 2-16d AT 12" O.C. 12"x10" (7" EMBEDMENT) ANCHOR BOLTS @ 6'-0" O.C. MAX. CONTINUOUS RIM OR END JOIST 8d @ 6" O.C. ALONG BRACED WALL PANEL BRACED WALL PANEL 3-16d @ 16" O.C. ALONG BRACED WALL PANEL CONTINUOUS RIM OR END JOIST ADDITIONAL FRAMING MEMBER DIRECTLY BELOW BRACED WALL PANEL ADDITIONAL FRAMING MEMBER DIRECTLY ABOVE BRACED WALL PANEL FULL-HEIGHT BLOCKING @ 16" O.C. ALONG BRACED WALL PANEL TOE NAIL 3-8d NAILS AT EACH BLOCKING MEMBER 2-16d NAILS EACH SIDE FULL-HEIGHT BLOCKING @ 16" O.C. ALONG BRACED WALL PANEL 3-16d @ 16" O.C. ALONG BRACED WALL PANEL 8d @ 6" O.C. ALONG BRACED WALL PANEL BRACED WALL PANEL 3-16d AT EACH BLOCKING MEMBER BRACED WALL PANEL CONTINUOUS RIM OR BAND JOIST 8d @ 6" O.C. ALONG BRACED WALL PANEL 8d @ 6" O.C. ALONG BRACED WALL PANEL BRACED WALL PANEL BRACED WALL PANEL 3-16d @ 16" O.C. ALONG BRACED WALL PANEL 3-16d @ 16" O.C. ALONG BRACED WALL PANEL FULL-HEIGHT BLOCKING CONTINUOUS ALONG LENGTH OF BRACED WALL PANEL FULL-HEIGHT BLOCKING CONTINUOUS ALONG LENGTH OF BRACED WALL PANEL DRAWN BY: DETAIL INFO: TX FIRM REG. NO. F-4031 WWW.CRITEXAS.COM DATE SHEET REVISION NOTES SCALE 05/02/24 S4.0 TY P I C A L L A T E R A L WI N D B R A C I N G D E T A I L S MI N . O V E R L A P 914" EXTENT OF HEADER WITH SINGLE PORTAL FRAME (ONE BRACED WALL PANEL: SEE NOTE) 2'-18' FINISHED WIDTH OF OPENING FOR SINGLE OR DOUBLE PORTAL EXTENT OF HEADER WITH DOUBLE PORTAL FRAMES (TWO BRACED WALL PANELS) 12 ' M A X . T O T A L W A L L H E I G H T 10 ' M A X . H E I G H T MIN.3"x11 14" NET HEADER STEEL HEADER PROHIBITED IF 12" SPACER IS USED, PLACE ON BACK-SIDE OF HEADER PO N Y W A L L HE I G H T OVER CONCRETE OR MASONRY BLOCK FOUNDATION OVER RAISED WOOD FLOOR - FRAMING ANCHOR OPTION (WHERE PORTAL SHEATHING DOES NOT LAP OVER BAND OR RIM JOIST) OVER RAISED WOOD FLOOR - OVERLAP OPTION (WHERE PORTAL SHEATHING LAPS OVER BAND OR RIM BOARD) SECTION @ A-AFRONT ELEVATION NOTE: HEADER SHALL NOT EXTEND OVER MORE THAN ONE OPENING. A-A A-A PORTAL FRAME (PFH) - WITH HOLD-DOWNS11 EXTENT OF HEADER WITH SINGLE PORTAL FRAME (ONE BRACED WALL PANEL: SEE NOTE) 2'-18' FINISHED WIDTH OF OPENING FOR SINGLE OR DOUBLE PORTAL EXTENT OF HEADER WITH DOUBLE PORTAL FRAMES (TWO BRACED WALL PANELS) 12 ' M A X . T O T A L W A L L H E I G H T 10 ' M A X . H E I G H T MIN.3"x11 14" NET HEADER STEEL HEADER PROHIBITED IF 12" SPACER IS USED, PLACE ON BACK-SIDE OF HEADER SECTION @ A-AFRONT ELEVATION NOTE: HEADER SHALL NOT EXTEND OVER MORE THAN ONE OPENING. A-A A-A PO N Y W A L L HE I G H T PORTAL FRAME AT GARAGE (PFG)12 CONTINUOUSLY SHEATHED PORTAL FRAME (CS-PF) 12"-24" C.I. PORTAL FRAME (PFH) - ALTERNATIVE14 METHOD MINIMUM PANEL LENGTH (inches) CONTRIBUTING LENGTH (inches)PORTAL HEADER HEIGHT 8 Feet 9 Feet 10 Feet 11 Feet 12 Feet PFH Supporting roof only 16 16 16 Note b Note b 48 Supporting one story and roof 24 24 24 Note b Note b 12" - 24" C.I. PFH Supporting roof only 12 12 12 Note b Note b 48 Supporting one story and roof 24 24 24 Note b Note b PFG 24 27 30 Note c Note c 1.5 x Actuala CS-PF SDC A, B AND C 16 18 20 Note d Note d 1.5 x Actuala a. Use the actual length where it is greater than or equal to the minimum length. b. Maximum header height for PFH, 12" PFH is 10 feet, but wall height shall be permitted to be increased of 12 feet with pony wall. c. Maximum header height for PFG is 10 feet, but wall height shall be permitted to be increased of 12 feet with pony wall. d. Maximum header height for CS-PF is 10 feet, but wall height shall be permitted to be increased of 12 feet with pony wall. MINIMUM LENGTH OF PANEL ON PORTAL FRAME13 SECTION B-B (2x4 WALL FRAMING) 10 ' - 0 " ( M A X ) 6'-0" TO 18"-0" EXTENT OF HEADER DOUBLE PORTAL FRAME (ONE BRACED WALL PANEL) 83 4" (12" C.I. PFH) 2034" (24" C.I. PFH)SECTION A-A A-A A-A B-B B-B 12 ' - 0 " ( M A X ) W I T H P O N Y W A L L MIN. (2) 2"x12" W/ 716" OSB SPACER HEADER OR EQUIVALENT ENGINEERED WOOD BEAM FRONT ELEVATION SECTION B-B (2x6 WALL FRAMING) BACK ELEVATION NAIL SOLE PLATE TO JOIST PER ADOPTED IRC CODE FASTEN SHEATHING TO HEADER WITH 8D COMMON OR GALVANIZED BOX NAILS IN 3" GRID PATTERN AS SHOWN HEADER TO JACK-STUD STRAP PER SCHEDULE ON DETAIL 10 ON BOTH SIDES OF OPENING OPPOSITE SIDE OF SHEATHING MIN. DOUBLE 2x4 FRAMING COVERED WITH MIN. 716" THICK WOOD STRUCTURAL PANEL SHEATHING WITH 8D COMMON OR GALVANIZED BOX NAILS AT 3" O.C. IN ALL FRAMING (STUDS, BLOCKING, AND SILLS) TYP. MIN. LENGTH OF PANEL PER TABLE ON DETAIL 13 TENSION STRAP PER SCHEDULE ON DETAIL 10 (ON OPPOSITE SIDE OF SHEATHING) IF NEEDED, PANEL SPLICE EDGES SHALL OCCUR OVER AND BE NAILED TO COMMON BLOCKING WITHIN THE MIDDLE 24" OF THE PORTAL-LEG HEIGHT. ONE ROW OF 3" O.C. NAILING IS REQUIRED IN EACH PANEL EDGE. TYPICAL PORTAL FRAME CONSTRUCTION MIN. DOUBLE 2x4 POST (KING AND JACK STUD). NUMBER OF JACK STUDS PER TABLES R602.7(1) & (2) U.N.O ON FRAMING PLAN FASTEN KING STUD TO HEADER WITH (6) 16D SINKERS FASTEN TOP PLATE TO HEADER WITH TWO ROWS OF 16D SINKER NAILS AT 3" O.C. TYP. MIN. 716" WOOD STRUCTURAL PANEL SHEATHING MIN. (2) 12" DIAMETER ANCHOR BOLT INSTALLED (MIN. 7" EMBEDMENT REQUIRED) - WITH 2"x2"x316" PLATE WASHER. BRACED WALL LINE CONTINUOUSLY SHEATHED WITH WOOD STRUCTURAL PANELS MEETING MINIMUM LENGTH REQUIREMENTS OF TABLE R602.10.5 OF ADOPTED IRC CODE. (INTERMITTENT BRACED WALL PANEL FOR PFG) ANCHOR BOLTS PER DETAIL 1 OR 2 WOOD STRUCTURAL PANEL SHEATHING TO TOP OF BAND OR RIM JOIST (2) FRAMING ANCHORS APPLIED ACROSS SHEATHING JOINT WITH A CAPACITY OF 670 LBS IN THE HORIZONTAL AND VERTICAL DIRECTIONS APPROVED BAND OR RIM JOIST NAIL SOLE PLATE TO JOIST PER ADOPTED IRC CODE WOOD STRUCTURAL PANEL SHEATHING TO TOP OF BAND OR RIM JOIST NAIL SOLE PLATE TO JOIST PER ADOPTED IRC CODE WOOD STRUCTURAL PANEL SHEATHING OVER APPROVED BAND OR RIM JOIST ATTACH SHEATHING TO BAND OR RIM JOIST WITH 8D COMMON NAILS AT 3" O.C. TOP AND BOTTOM APPROVED BAND OR RIM JOIST NAIL SOLE PLATE TO JOIST PER ADOPTED IRC CODE WOOD STRUCTURAL PANEL SHEATHING OVER APPROVED BAND OR RIM JOIST FASTEN SHEATHING TO HEADER WITH 8D COMMON OR GALVANIZED BOX NAILS IN 3" GRID PATTERN AS SHOWN HEADER TO JACK-STUD STRAP PER SCHEDULE ON DETAIL 10 ON BOTH SIDES OF OPENING OPPOSITE SIDE OF SHEATHING HEADER IS PERMITTED TO EXTEND TO THE END OF A PORTAL WITH A BEARING BLOCK IF PONY WALL NOT PRESENT AND A 1000 POUND TENSION STRAP IS PROVIDED. MIN. DOUBLE 2x4 FRAMING COVERED WITH MIN. 3 8" THICK WOOD STRUCTURAL PANEL SHEATHING WITH 8D COMMON OR GALVANIZED BOX NAILS AT 3" O.C. IN ALL FRAMING (STUDS, BLOCKING, AND SILLS) TYP. MIN. LENGTH OF PANEL PER TABLE ON DETAIL 13 (2) STHD14 SIMPSON Strong-Tie OR MIN. (2) 3500 LB STRAP-TYPE HOLD-DOWNS (EMBEDDED INTO CONCRETE WITH MANUFACTURER'S REQUIRED EDGE DISTANCE AND NAILED TO FRAMING) MIN. REINFORCING OF FOUNDATION, ONE #4 BAR TOP AND BOTTOM OF FOOTING. LAP BARS 15" MIN. MIN. FOOTING SIZE UNDER OPENING IS 12"x12". A TURNED-DOWN SLAB SHALL BE PERMITTED AT DOOR OPENINGS. MIN. (1) 5 8" DIAMETER ANCHOR BOLT INSTALLED (MIN. 7" EMBEDMENT REQUIRED) - WITH 2"x2"x316" PLATE WASHER. TENSION STRAP PER SCHEDULE ON DETAIL 10 (ON OPPOSITE SIDE OF SHEATHING) IF NEEDED, PANEL SPLICE EDGES SHALL OCCUR OVER AND BE NAILED TO COMMON BLOCKING WITHIN THE MIDDLE 24" OF THE PORTAL-LEG HEIGHT. ONE ROW OF 3" O.C. NAILING IS REQUIRED IN EACH PANEL EDGE. TYPICAL PORTAL FRAME CONSTRUCTION MIN. DOUBLE 2x4 POST (KING AND JACK STUD). NUMBER OF JACK STUDS PER TABLES R602.7(1) & (2) U.N.O ON FRAMING PLAN LSTHD8 SIMPSON Strong-Tie OR MIN. 1000 LB. HOLD-DOWN DEVICE (EMBEDDED INTO CONCRETE AND NAILED INTO FRAMING FASTEN KING STUD TO HEADER WITH (6) 16D SINKERS FASTEN TOP PLATE TO HEADER WITH TWO ROWS OF 16D SINKER NAILS AT 3" O.C. TYP. MIN. 3 8" WOOD STRUCTURAL PANEL SHEATHING TREATED SP BOTTOM PLATE EACH SIDE MIN. 3500 LB TIE DOWN (REF. SIMPSON STHD14) ATTACHED DIRECTLY TO FLUSH EDGES OF STUDS, INSTALLED PER MANUFACTURER'S RECOMMENDATION 716" OSB FASTENED BETWEEN (4) FLATWISE 2x4. 2x4 FRAMING MEMBERS TO BE NAILED WITH (2) 3"x0.131" NAILS, EVERY 6" ON INTERIOR SIDE OF THE PIERS. NAIL KING STUD W/ (2) 314"x0.131" NAILS @ 6" O.C. EACH SIDE OF PORTAL FRAME MIN. 3500 LB TIE DOWN DEVICE (REF. SIMPSON STHD14) ATTACHED DIRECTLY TO FLUSH EDGES OF STUDS. MAY BE PLACED ON EITHER TO FRONT OR BACK-SIDE OF THE PIER OSB, PLYWOOD, OX-IS, THERMO-PLY OR ISO-RED CI SHEATHING-INSTALL WITH 1" CROWN 114" LONG 16 GA STAPLES (MINIMUM) , AT 3" ON-CENTER, ON THE EXTERIOR WALL - USE CONSTRUCTION ADHESIVE ASTM C-557 OVER 3500 LBS HOLD-DOWN FOR ATTACHMENT IF NECESSARY 2990LB HEADER STRAPS (REF. SIMPSON MSTC-28 OR EQUIVALENT) ATTACHED OVER SHEATHING OPTIONAL PONY WALL - OSB, PLYWOOD, OX-IS, SI-STRONG, THERMO-PLY OR ISO-RED CI CONTINUOUS FROM TOP PLATE TO BOTTOM EDGE OF HEADER BEAM. ALL EDGES BLOCKED & FASTENED @ 3" O.C. ON ALL FRAMING MEMBERS 3 ROWS OF FASTENERS ON HEADER @ 3" O.C. 716" OSB MIN. LENGTH OF PANEL PER TABLE ON DETAIL 13 2990LB HEADER STRAPS (REF. MSTC-28 OR EQUIVALENT) ATTACHED TO HEADER AND JACK STUDS (OR BOTH JACK AND KING STUDS AS APPLICABLE) OVER SHEATHING. NAIL PER MANUFACTURER'S RECOMMENDATION. FILL ALL NAIL HOLES. RESISTANCE TO ANY OUT-OF-PLANE LOADING REQUIREMENTS SHALL BE IN ACCORDANCE WITH TABLE IN DETAIL 10 OR ADOPTED IRC. 2x4 SPF PLATE BETWEEN STUDS AND HEADER (OPTIONAL) CONTINUOUS 2x4 STUD ATTACHED OVER SHEATHING. FASTEN WITH 2 ROWS OF 3" x 0.131" NAILS SPACED 4" O.C. TO KING STUD, JACK STUDS, AND HEADER. WHERE THE PORTAL FRAME IS NOT LOCATED AT THE CORNER OF A BUILDING, THIS STUD IS PERMITTED TO BE REPLACED WITH A 2990LB HEADER STRAP (REF. SIMPSON MSTC-28 OR EQUIVALENT). (2) 2x12 w/ 716" OSB SPACER HEADER OR EQUIVALENT ENGINEERED WOOD BEAM 2x4 FLAT-WISE 2x4 FLAT-WISE 2x6 STUD 2990 LB HEADER STRAPS (TYP. 3 LOCATIONS) OPTIONAL: FILL CAVITY OF PIER WITH 1 12" THICK PIECES OF OSB, PLYWOOD OR ISO-RED CONTINUOUSLY INSULATED (CI) (OR EQUIVALENT) 716" OSB 2990 LB HEADER STRAPS (TYP. 3 LOCATIONS) 2x4 STUD OSB, PLYWOOD, OX-IS, SI-STRONG, ISO RED CI, OR THERMO-PLY SHEATHING HEADER VERTICAL STRAPS CONNECTING HEADER TO JACK STUDS OF PIERS. CENTER VERTICAL STRAPS (26" MIN. LENGTH) AT THE BOTTOM OF THE HEADER AND ALIGN TO INSIDE FACE OF JACK STUD 2x4 STUD WHEN PERPENDICULAR WALL IS PRESENT TO CONNECT HEADER. WHERE THE PORTAL FRAME IS NOT AT CORNER OF THE BUILDING, THIS STUD IS PERMITTED TO BE REPLACED WITH A STRAP (2990 LB STRAP TO FLUSH AT OUTSIDE EDGE OF KING STUD) JACK STUDS FOUNDATION PER ADOPTED CODE DRAWN BY: DETAIL INFO: TX FIRM REG. NO. F-4031 WWW.CRITEXAS.COM DATE SHEET REVISION NOTES SCALE 05/02/24 S4.1 TY P I C A L L A T E R A L WI N D B R A C I N G D E T A I L S ()3 -2x6 7' ()3-2x8 10' ()3-2x6 6'()2-2x12 14' ()3-2x12 16' ()3-2x12 16' ()2 -2x6 3' ()3 -2x8 7'()3 -2x6 4' ()3-2x12 16'-13 4" x 18" LVL ()2 24' -13 4" x 16" LVL ()2 16' -1 3 4" x 1 6 " L V L ( ) 2 16 ' -1 3 4" x 1 6 " L V L ( ) 2 22 ' ( ) 3-2 x 6 3' ( ) 3 -2 x 6 4' ( ) 2-2 x 6 3' ( ) 3 -2 x 6 4' ( ) 2-2 x 1 2 6' ( ) 3-2 x 6 7' CRI IS NOT RESPONSIBLE FOR FLOOR SYSTEM DESIGN. REFER TO FLOOR LAYOUTS AND DIAGRAMS BY FLOOR SYSTEM ENGINEER FOR ALL APPLICABLE DESIGN INFORMATION. ALL HEADERS UNDER FLOOR LAYOUT TO BE SIZED BY FLOOR SYSTEM ENGINEER. BE A M S S I Z E D B Y FL O O R S Y S T E M EN G I N E E R , T Y P . U . N . O . BEAMS SIZED BY FLOOR SYSTEM ENGINEER, TYP. U.N.O. BEAMS SIZED BY FLOOR SYSTEM ENGINEER, TYP. U.N.O. DB L DBL DB L 2x 8 @ 2 4 " O . C . USE BOLTED LINTEL PER DETAIL D/S6.0 USE BOLTED LINTEL PER DETAIL D/S6.0 OPEN TO ABOVE DB L BEAMS SIZED BY FLOOR SYSTEM ENGINEER, TYP. U.N.O. HEADERS NOT DESIGNED TO SUPPORT MASONRY, TYP. 6x6 WOOD POST W/ SIMPSON METAL POST BASE AND CAP, TYP. BEAMS SIZED BY FLOOR SYSTEM ENGINEER, TYP. U.N.O. BEAMS SIZED BY FLOOR SYSTEM ENGINEER, TYP. U.N.O. BE A M S S I Z E D B Y FL O O R S Y S T E M EN G I N E E R , T Y P . U . N . O . DRAWN BY: JOB NUMBER: TX FIRM REG. NO. F-4031 WWW.CRITEXAS.COM DATE SHEET REVISION NOTES SCALE THE LENGTHS OF FRAMING MEMBERS GIVEN IS A COURTESY EXTENDED TO THE CLIENT FROM CRI, AND SHOULD BE USED FOR COST ESTIMATION PURPOSES ONLY. ACTUAL LENGTHS SHOULD BE VERIFIED PRIOR TO CONSTRUCTION. NOTES THESE PLANS AND SPECIFICATIONS ARE THE SOLE PROPERTY OF CRI AND MAY ONLY BE USED ONCE FOR THE SINGLE SITE OR LOT LOCATION FOR WHICH THEY ARE PREPARED. NO OWNERSHIP RIGHTS ARE CONVEYED FOR THE FUTURE USE OF THESE PLANS. THE REPRODUCTION OR REUSE OF THESE PLANS AND SPECIFICATIONS AT ANY OTHER LOCATION OR FOR ANY OTHER PURPOSE IS STRICTLY PROHIBITED. S5.0 CEILING FRAMING PLAN 03/26/25 34 0 5 W I T T C O U R T MA Y K U S H O M E S & N E I G H B O R H O O D S 2021 COMPOSITION SHINGLE OR METAL ROOF. PLAN NOTES: 1.ALL CONSTRUCTION SHALL CONFORM TO THE REQUIREMENTS OF THE ____ EDITION OF THE INTERNATIONAL RESIDENTIAL CODE. 2.DESIGN IS FOR A 2x6 RAFTERS @ O.C. TYP. (U.N.O) 3.CEILING JOISTS SHALL BE 2x6 @ ON CENTER UNLESS NOTED OTHERWISE. 4.REFERENCE FRAMING NOTES SHEET FOR ADDITIONAL REQUIREMENTS. 5.NO STORAGE ALLOWED IN ATTIC (U.N.O.) EXCEPT IN HATCHED AREA 24" 24" ()3-2x12 14' ()2-2x6 3' ()2 -2x6 4' ()3-2x10 12'()3-2x10 14' ()3-2x6 6'()2-2x6 4' ()3-2x6 4' ()2-2x6 3' ()2-2x6 5' ()3-2x10 14'()3-2x10 12'()3-2x10 14' ()3-2x10 14' ()3 -2x6 4'()3 -2x6 4'()3 -2x6 4' ()2 -2x6 5' ()2-2x6 5' ()3 -2x6 3' ()3-2x10 7' ( ) 3 -2 x 8 7' ( ) 2 -2 x 6 3' ( ) 2-2 x 6 3' ( ) 2-2 x 6 4' ( ) 2 -2 x 6 3' ( ) 2 -2 x 6 3' ( ) 3 -2 x 6 4' ( ) 3-2 x 6 3' ( ) 2-2 x 1 2 14 ' ( ) 2-2 x 1 2 14 ' ( ) 3 -2 x 6 3' ( ) 3-2 x 1 2 14 ' ( ) 2 -2 x 6 5' ()2-2x6 3' ( ) 2 -2 x 6 5' -1 3 4" x 1 4 " L V L ( ) 3 20 ' -1 3 4" x 1 4 " L V L ( ) 3 18 ' ( ) 3 -2 x 6 5' ( ) 3 -2 x 8 7' ()2-2x6 4' ()2-13 4" x 117 8" LVL 7' ()2-2x12 12' ( ) 2-2 x 6 6' CONTINUOUS HEADER CONTINUOUS HEADER CO N T I N U O U S H E A D E R CO N T I N U O U S H E A D E R HATCH INDICATES LIMITED ATTIC STORAGE. DB L DB L DB L DB L DB L DB L DBL DBL DBLDBL BO T T O M F L U S H W I T H C E I L I N G BR A C E T O P E D G E E V E R Y 8 ' - 0 " BO T T O M F L U S H W I T H C E I L I N G BR A C E T O P E D G E E V E R Y 8 ' - 0 " (5)2x4 STUD PACK DB L (4)2x4 STUD PACK DBL DBL DBL (3)2x4 STUD PACK EA. END BUILD PONY WALL ABOVE UP TO ROOF DB L DB L DRAWN BY: JOB NUMBER: TX FIRM REG. NO. F-4031 WWW.CRITEXAS.COM DATE SHEET REVISION NOTES SCALE THE LENGTHS OF FRAMING MEMBERS GIVEN IS A COURTESY EXTENDED TO THE CLIENT FROM CRI, AND SHOULD BE USED FOR COST ESTIMATION PURPOSES ONLY. ACTUAL LENGTHS SHOULD BE VERIFIED PRIOR TO CONSTRUCTION. NOTES THESE PLANS AND SPECIFICATIONS ARE THE SOLE PROPERTY OF CRI AND MAY ONLY BE USED ONCE FOR THE SINGLE SITE OR LOT LOCATION FOR WHICH THEY ARE PREPARED. NO OWNERSHIP RIGHTS ARE CONVEYED FOR THE FUTURE USE OF THESE PLANS. THE REPRODUCTION OR REUSE OF THESE PLANS AND SPECIFICATIONS AT ANY OTHER LOCATION OR FOR ANY OTHER PURPOSE IS STRICTLY PROHIBITED. S5.1 2nd FLR. CEILING FRAMING PLAN 03/26/25 34 0 5 W I T T C O U R T MA Y K U S H O M E S & N E I G H B O R H O O D S 2021 COMPOSITION SHINGLE OR METAL ROOF. PLAN NOTES: 1.ALL CONSTRUCTION SHALL CONFORM TO THE REQUIREMENTS OF THE ____ EDITION OF THE INTERNATIONAL RESIDENTIAL CODE. 2.DESIGN IS FOR A 2x6 RAFTERS @ O.C. TYP. (U.N.O) 3.CEILING JOISTS SHALL BE 2x6 @ ON CENTER UNLESS NOTED OTHERWISE. 4.REFERENCE FRAMING NOTES SHEET FOR ADDITIONAL REQUIREMENTS. 5.NO STORAGE ALLOWED IN ATTIC (U.N.O.) EXCEPT IN HATCHED AREA 24" 24" ( ) 2 x 8 5' () 2x8 20' () 2x8 22'() 2x8 20'() 2x8 20' () 2x8 20' ( ) 2 x 8 20 ' ( ) 2 x 8 12 ' ( ) 2 x 8 16 ' ( ) 2 x 8 16 ' ( ) 2 x 8 12 ' ( ) 2 x 8 16' ( ) 2x8 1 6 ' ( ) 2 x 8 1 4 ' ( ) 2x8 1 4 ' ( ) 2x 8 7' ( ) 2 x 8 14' ( ) 2x 8 14' ( ) 2 x 8 1 4 ' 2x6 RAFTERS @ 24" O.C., TYP. U.N.O. 2x6 PURLIN, TYP. U.N.O. PITCH BREAK METAL ROOF BY OTHERS WALL SUPPORTED BY CEILING BELOW DRAWN BY: JOB NUMBER: TX FIRM REG. NO. F-4031 WWW.CRITEXAS.COM DATE SHEET REVISION NOTES SCALE THE LENGTHS OF FRAMING MEMBERS GIVEN IS A COURTESY EXTENDED TO THE CLIENT FROM CRI, AND SHOULD BE USED FOR COST ESTIMATION PURPOSES ONLY. ACTUAL LENGTHS SHOULD BE VERIFIED PRIOR TO CONSTRUCTION. NOTES THESE PLANS AND SPECIFICATIONS ARE THE SOLE PROPERTY OF CRI AND MAY ONLY BE USED ONCE FOR THE SINGLE SITE OR LOT LOCATION FOR WHICH THEY ARE PREPARED. NO OWNERSHIP RIGHTS ARE CONVEYED FOR THE FUTURE USE OF THESE PLANS. THE REPRODUCTION OR REUSE OF THESE PLANS AND SPECIFICATIONS AT ANY OTHER LOCATION OR FOR ANY OTHER PURPOSE IS STRICTLY PROHIBITED. S5.2 ROOF FRAMING PLAN 03/26/25 34 0 5 W I T T C O U R T MA Y K U S H O M E S & N E I G H B O R H O O D S 2021 COMPOSITION SHINGLE OR METAL ROOF. PLAN NOTES: 1.ALL CONSTRUCTION SHALL CONFORM TO THE REQUIREMENTS OF THE ____ EDITION OF THE INTERNATIONAL RESIDENTIAL CODE. 2.DESIGN IS FOR A 2x6 RAFTERS @ O.C. TYP. (U.N.O) 3.CEILING JOISTS SHALL BE 2x6 @ ON CENTER UNLESS NOTED OTHERWISE. 4.REFERENCE FRAMING NOTES SHEET FOR ADDITIONAL REQUIREMENTS. 5.NO STORAGE ALLOWED IN ATTIC (U.N.O.) EXCEPT IN HATCHED AREA 24" 24" NOTE: 3x3x1/4 STEEL PLATE STOPS WELDED TO ANGLE @24" O.C. FOR ROOF PITCH GREATER THAN 7:12 BUT NO MORE THAN 12:12 12 SEE ARCH'L. ARCH'L. ROOF, SEE ARCH'L DWGS. 716" PLYWOOD ROOF SHEATHING RAFTERS, SEE PLAN SEE ARCH'L DWGS. FOR SOFFIT, EAVE DETAILS ARCH'L. FINISH SEE ARCH'L DWGS. WALL SHEATHING STUDS @ 16" O.C. DOUBLE TOP PLATE CEILING JOIST, SEE PLAN SECTION A MASONRY VENEER, SEE ARCH'L DWGS. WALL SHEATHING STUDS @ 16" O.C. INTERMEDIATE DOUBLE PLATE AT CEILING FRAMING. WHERE CEILING FRAMING IS NOT PRESENT WALL MUST BE CONTINUOUS TO ROOF CEILING JOIST, SEE PLAN RAFTERS, SEE PLAN OUTLOOKERS: 2x4 @ 24" O.C. UP TO 3' OVERHANG OR 2x6 @ 24" O.C. UP TO 4' OVERHANG ARCH'L. ROOF, SEE ARCH'L DWGS. 716" PLYWOOD ROOF SHEATHING VA R I E S SECTION B 12 SEE ARCH'L. ARCH'L. ROOF, SEE ARCH'L DWGS.7 16" PLYWOOD ROOF SHEATHING RAFTERS, SEE PLAN SEE ARCH'L DWGS. FOR SOFFIT, EAVE DETAILS WALL SHEATHING STUDS @ 16" O.C. DOUBLE TOP PLATE SECTION C 12 SEE ARCH'L. ARCH'L. ROOF, SEE ARCH'L DWGS. 7 16" PLYWOOD ROOF SHEATHING RAFTERS, SEE PLAN SEE ARCH'L DWGS. FOR SOFFIT, EAVE DETAILS L6x4x3 8 STEEL LINTEL 8" MIN. BEARING EACH END. BOLT TO WOOD HEADER W/2- 12"Øx3" LAG BOLTS @ 16" O.C. PROVIDE 4" BEARING & RUST INHIBITIVE PAINT WALL SHEATHING CEILING JOIST, SEE PLAN DOUBLE TOP PLATE STUDS @ 16" O.C. GARAGE HEADER, SEE PLAN FOUR #2 YP 2x STUDS UNDER END OF HEADER BEYOND (TYP.) SECTION D 12 SEE ARCH'L. ARCH'L. ROOF, SEE ARCH'L DWGS. 7 16" PLYWOOD ROOF SHEATHING RAFTERS, SEE PLAN SEE ARCH'L DWGS. FOR SOFFIT, EAVE DETAILS CEILING JOIST, SEE PLAN WOOD BEAM, SEE PLAN SECTION E STUD WALL PER PLAN ATTACH FIRST RAFTER TO EACH STUD W/ (3) 3/8"X5" LAG SCREWS MASONRY VENEER, SEE ARCH'L DWGS. L4x4x14 STEEL LINTEL. LOCATE DIRECTLY ON TOP OF ROOF CONSTRUCTION TOP OF ROOF DECKING (TYP) TRIPLE RAFTERS ATTACHED TO STUD WALL (TYP) SEE ARCH'L DWGS. FOR SOFFIT, EAVE DETAILS ARCH'L. FINISH SEE ARCH'L DWGS. ARCH'L. FINISH SEE ARCH'L DWGS. BLOCKING BLOCKING BLOCKING BLOCKING BLOCKING DOUBLE RAFTER DOUBLE TOP PLATE STONE VENEERHEADER MORTAR JOINT LOOSE LINTEL PER SCHEDULE STUD WALL LOOSE LINTEL SECTION SIZE OF STEEL ANGLE (INCHES) NO STORY ABOVE 6'-0"4'-6" 8'-0"6'-0" 10'-0"8'-0" 14'-0"9'-6" 3 x 3 x 14 4 x 3 x 14 5 x 312 x 5 16 6 x 312 x 5 16 ONE STORY ABOVE ALLOWABLE SPANS FOR LINTELS SUPPORTING MASONRY VENEER 6" X 4" X 5/16" STEEL ANGLE ATTACHED TO STUD WITH FASTENERS MASONRY VENEER STUD WALL W/DOUBLED STUDS@16" O.C. VENEER TIE ROOF FRAMING 7 16" ROOF DECK 7 16" WALL SHEATHING 2- 1/2"Ø X 4" LAG SCREWS @ 16" O.C. FLASHING BY OTHERS CONT, LEDGER ONE SIZE LARGER THAN RAFTER FOR SLOPES UP TO 9:12 TWO SIZES LARGER THAN RAFTER FOR SLOPES EXCEEDING 9:12 2- 1/2"Ø X 4" LAG SCREWS @ 16" O.C. LOOSE LINTEL DETAIL J VENEER ABOVE ROOF SECTION I SUPPORT OF MASONRY BLOCKING VENEER ABOVE ROOF SECTION H SUPPORT OF MASONRY DORMER FRAMING DETAIL G STUDS FOR EXTERIOR WALL TOP PLATE FOR EXTERIOR WALL DOUBLE HEADER STUDS FOR GABLE DORMER TOP PLATE FOR GABLE DORMER DOUBLE HEADER CEILING JOISTS, SEE PLAN FOR SIZE AND SPACING TRIPLE RAFTER ROOF RAFTERS, SEE PLAN FOR SIZE AND SPACING RIDGE BOARD, SEE PLAN FOR SIZE VALLEY BOARD, SEE PLAN FOR SIZE KN E E B R A C E RA F T E R KN E E B R A C E RA F T E R KN E E B R A C E KN E E B R A C E KN E E B R A C E KN E E B R A C E RA F T E R NOTES 1.KNEE BRACES SHALL BE SAME DIMENSIONAL SIZE AS RAFTERS. 2.KNEE BRACES SHALL BE NAILED TO THE SIDE OF THE RAFTERS W/ 2-10d NAILS @ 16" O.C. 3.AT CEILING JOISTS, PROVIDE 4-10d FACE NAILS FROM EACH SIDE BETWEEN RAFTER AND CEILING JOIST. 4.AT CEILING BEAM PROVIDE 21-10d FACE NAILS @ 2" O.C. EACH WAY FROM EACH SIDE BETWEEN RAFTERS AND BEAM. KNEE B R A C E RAFT E R B E Y O N D CEILING JOIST REF. NOTE 3 2-PLY BEAM AT CEILING REF. NOTE 4 KNEE BRACE CONNECTION DETAIL F CUT KNEE BRACE TO FIT TIGHT ALONG BOTTOM OF CEILING JOIST RA F T E R RA F T E R NOTES: 1.MASONRY VENEER SHALL NOT SUPPORT ANY VERTICAL LOAD OTHER THAN THE LOAD OF THE VENEER ABOVE 2.PROVIDE MINIMUM 4" BEARING AT EACH END OF THE OPENING 3.PROVIDE ONE ANGLE FOR EACH 4" NOMINAL WYTHE OF VENEER 4.LONG LEG OF ANGLE SHALL BE PLACED IN THE VERTICAL POSITION 5.STEEL LINTELS SHALL BE SHOP COATED WITH A RUST-INHIBITIVE PAINT, EXCEPT FOR LINTELS MADE OF CORROSION-RESISTANT STEEL OR STEEL TREATED WITH COATINGS TO PROVIDE CORROSION RESISTANCE 6.IF SPAN EXCEEDS ALLOWABLE SPAN LISTED IN TABLE, USE A BOLTED LINTEL PER DETAIL D 3-PLY BEAM AT CEILING REF. NOTE 4 CEILING JOIST OR BEAM ATTACH 2ND & 3RD RAFTER W/ 2-10d NAILS @ 16" O.C. DOUBLE CEILING JOIST DRAWN BY: DETAIL INFO: TX FIRM REG. NO. F-4031 WWW.CRITEXAS.COM DATE SHEET REVISION NOTES SCALE 05/18/23 S6.0 DE T A I L S H E E T T Y P I C A L F R A M I N G PERSPECTIVE ROOF OPENING SIMPSON A35 - ANGLE, SEE MANUFACTURER FOR INSTALLATION AND FASTENING REQ'S. CHIMNEY FRAMING DETAIL O FLOOR TRUSS SECTIONS P 2" 2"13 4" ASSEMBLY A: 3 ROWS OF 10d NAILS @ 12" O.C. ALL MULTIPLE PLY-MEMBERS TO BE NAILED, SCREWED OR BOLTED TOGETHER. AS PER DETAIL ASSEMBLY "A" 2 PLY OF 13 4" ASSEMBLY "B" 3 PLY OF 13 4" ASSEMBLY "C" 4 PLY OF 13 4" ELEVATION PLAN 3'-0" MAX 3' - 0 " M A X 1X4 LET IN BRACE TYP. EACH FACE SECURE TO STUDS WITH 2- 16D NAILS AT EACH STUD. 3- 2X4 STUDS, TYP. EA. CORNER DOUBLE TOP PLATE 20 ' - 0 " M A X ( N . T . S . ) 3'-0" MAX DOUBLE TOP PLATE ROOF STRUCTURE, SHOWN GRAYED OUT FOR CLARITY SIMPSON RPS 18 STRAP. SECURE TO STUDS WITH 2- 16D NAILS AT EACH END TYP. AT EACH CORNER. 1X4 BRACE TYP. EACH FACE SECURE TO STUDS WITH NAILING PER TABLE R602.3 IN THE EDITION OF THE IRC ADOPTED BY THE LOCAL JURISTICTION 3- 2X4 STUDS, TYP. EA. CORNER SECURE DOUBLE TOP PLATE TO STUDS PER TABLE R602.3 IN THE EDITION OF THE IRC ADOPTED BY THE LOCAL JURISTICTION 716" PLYWOOD OR OSB SHEATHING 2X4 @ 16" O.C. MAX STUDS 30° MIN TYP NOTCH STUD FOR LET-IN BRACE, TYP. 716" SHEATHING CONTINUOUS TO PLATE BELOW ROOF FRAMING CONTINUE LET-IN BRACING TO FOUNDATION 1 1. 7 5 MA X 716" PLYWOOD OR OSB SHEATHING WITH 6d NAILS @ 4" O.C. AT EDGES AND @ 12" O.C. FOR INTERMEDIATE SUPPORTS. BLOCK ALL EDGES THAT ARE NOT AT STUDS OR PLATES. EXTERIOR STUD WALL TYP. 3 4" PLYWOOD FLOOR DECK FLOOR TRUSS BY TRUSS MANUFACTURER OR I JOIST BLOCKING BETWEEN TRUSSES PER TRUSS MANUFACTURER CONT. DOUBLE TOP PLATE 7 16" PLYWOOD WALL SHEATHING 2x4 BRIDGING @ 24" O.C. CONT. DOUBLE TOP PLATE LADDER TRUSS BY TRUSS MANUFACTURER OR RIM BOARD FLOOR TRUSS PER TRUSS MANUFACTURER OR I JOIST 7 16" PLYWOOD WALL SHEATHING EXTERIOR STUD WALL TYP. 3 4" PLYWOOD FLOOR DECK ASSEMBLY B: 3 ROWS OF 10d NAILS @ 9" O.C. ASSEMBLY C: 2 ROWS SIMPSON SDS @ 16" O.C. OR 2 ROWS OF 12" THROUGH BOLTS @ 12" O.C. 2" 2" 2" 2" SIMPSON SDS (TYP.) WOOD BEAMS, REFERENCE PLAN REFERENCE HANGER SCHEDULE (TYP) 4-1/4"x3 12" SDS BY SIMPSON ON EACH SIDE OF SUPPORTED BEAM AS SHOWN 8-SCREW CONNECTION DETAIL L TYPICAL SIDE LOADED LVL 11 2" M I N . 2" 2" EQ U A L SP A C I N G MULTIPLE MEMBER CONNECTION DETAIL K CONNECTION DETAIL R COLUMN BASE 2" MIN. SIDECOVER (TYP) FASTEN WITH 6-10d 12"Ø HILTI KWIK-BOLT 3 TREATED 4x4 COLUMN CONCRETE FOUNDATION (TYP) 4x4 COLUMN FASTEN WITH 8-12d 5 8"Ø HILTI KWIK-BOLT 3 TREATED 6x6 COLUMN SIMPSON ABW44Z FOR 4x4 OR ABW44RZ FOR 4x4 ROUGH SAWN CEDARSIMPSON ABW66Z FOR 6x6 OR ABW66RZ FOR 6x6 ROUGH SAWN CEDAR CONNECTION (TOP) DETAIL Q BEAM TO COLUMN ~ BEAMS PER PLAN (TYP) FILL ALL HOLES W/ 16d NAILS (TYP) 4x4 COLUMN: SIMPSON AC4 AT MIDSPAN & ACE4 AT CORNERS (TYP) 6x6 COLUMN: SIMPSON AC6 AT MIDSPAN & ACE6 AT CORNERS (TYP) CONTINUOUS COLUMN PER PLAN (TYP) SPLICED MEMBER 2x4x2' BRACE NAILED W/ 3-10d NAILS (6 TOTAL) TO BOTH HIP/VALLEY/RIDGE BOARDS 7 16"x2" PLYWOOD OR OSB (BOTH SIDES) NAILED W/ 8-8d NAILS FROM EACH SIDE AS SHOWN (16 TOTAL) 2x6 BRACE 2x6 STRONGBACK CENTER ALL MEMBERS ON SPLICE POINT SPLICE DETAIL M HIP/VALLEY/RIDGE SPLICE POINT MUST OCCUR AT BRACE INSTALL 2x4 DIAGONAL BRACES AT 45° FROM TOP OF BEAM TO PLATE. CONNECT W/ (3) 3x0.0131 TOE NAILS EACH END REFERENCE FRAMING NOTES FOR ADDITIONAL BRACING REQUIREMENTS ADD FULL HEIGHT STUDS BELOW BEAM FOR BEARING PER NOTES BEAM BRACING DETAIL T FLOOR TRUSSES PARALLEL TO WALL ABOVE NON-LOAD BEARING WALL PARALLEL TO TRUSSES BELOW 2X6 BLOCKING @24" O.C. 2X BLOCKING 3 4" PLYWOOD FLOOR DECKING BOTTOM PLATE PARALLEL TRUSS/WALL DETAIL S CEILING JOIST DBL. TOP PLATE 6x6 COLUMN WOOD BEAM, REF. PLAN NOTE: WHERE SUPPORTING BEAM IS 3 OR 4 PLIES, 8 ADDITIONAL SDS SCREWS ARE REQUIRED AT THE BACK SIDE OF THE BEAM. 4-10d NAILS FROM EACH SIDE (8 TOTAL) PURLIN REFERENCE PLANRAFTER REFERENCE PLAN RAFTER SPLICE AT PURLIN N 2'-0 " M I N . L A P CEN T E R E D O N PUR L I N STIFFBACK PER FRAMING NOTES BRACE PER FRAMING NOTES DRAWN BY: DETAIL INFO: TX FIRM REG. NO. F-4031 WWW.CRITEXAS.COM DATE SHEET REVISION NOTES SCALE 05/18/23 S6.1 DE T A I L S H E E T T Y P I C A L F R A M I N G FACE MOUNT HANGER SCHEDULE MEMBER SIMPSONS PRODUCT NUMBER CAPACITY (lbs) (100%) 2x4 2x6, 2x8 2x10 2x12 2-2x4 2-2x6, 2-2x8 2-2x10, 2-2x12 2-1.75x11.25 LVL 2-1.75x14 LVL, 2-1.75x16 LVL 2-1.75x18 LVL 3-2x10 3-2x12 3-1.75x11.25 LVL 3-1.75x14-24 LVL 4-2x10, 4-2x12 4-1.75x11.25 LVL 4-1.75x14-24 LVL ALL 5 PLY LVL 45° SKEWED HANGER 2x6 2x8 2x10, 2x12 2-2x6, 2-2x8 2-2x10, 2-2x12 2-1.75x11.25 LVL, 2-1.75x14 LVL 2-1.75x16 LVL, 2-1.75x18 LVL OR APPROVED EQUAL* LUS24 LUS26 LUS28 LUS210 LUS24-2 HGUS48 HU210-3 HU212-3 HGUS5.50/12 HHUS210-4 HGUS7.25/12 HHGU9.00-SDS LSU26 LSSU28 LSSU210 SUR/L26-2 HSUR/L414 LUS26-2 LUS210-2 HGUS410 HGUS414 HGUS5.50/14 HGUS7.25/14 SUR/L210-2 HSUR/L410 670 865 1100 1340 800 1030 1830 7460 9100 10100 2085 2380 9600 10100 5635 9600 10100 17845 695 885 995 1150 2015 2975 3870 3-1.75x9.25 LVL HGUS5.50/10 9100 4-1.75x9.25 LVL HGUS7.25/10 9100 2-1.75x9.25 LVL HGUS410 9100 2-1.75x24 LVL HGU3.63-SDS 13160 WHERE THIS FOOTNOTE IS REFERENCED ON THE PLAN, USE THE FOLLOWING SIMPSON STRONG-DRIVE SDS FACE SCREWS IN LIEU OF NAILS WITH A SIMPSON FACE MOUNT HANGER SELECTED FROM THE TABLE ABOVE. WHEN THE FOLLOWING FACE SCREWS ARE NOT COMPATIBLE WITH THE SELECTED FACE MOUNT HANGER, SELECT AN EQUIVALENT OR STRONGER COMPATIBLE HANGER. FACE MOUNT (SUPPORTING)FACE MOUNT STRONG-DRIVE BEAM NUMBER OF PLIES:SDS SCREWS REQUIRED: 2-PLY 1/4" X 3-1/2" SDS 3-PLY 1/4" X 5" SDS 4-PLY 1/4" X 8" SDS 1 1 STRUCTURAL NOTES THESE STRUCTURAL NOTES SHALL APPLY UNLESS OTHERWISE SPECIFICALLY NOTED ON PLANS AND DETAILS. THE CONTRACTOR SHALL VERIFY ALL DIMENSIONS, NEW AND/OR EXISTING, AND SHALL COORDINATE ALL STRUCTURAL PLANS AND DETAILS WITH ARCHITECTURAL DRAWINGS BEFORE STARTING WORK. THE ENGINEER SHALL BE NOTIFIED OF ANY DISCREPANCIES PRIOR TO CONSTRUCTION. IN CASE THERE ARE DISCREPANCIES AMONG DRAWINGS AND NOTES, THE MORE STRINGENT REQUIREMENT SHALL GOVERN. DESIGN, CONSTRUCTION, WORKMANSHIP AND MATERIALS SHALL COMPLY WITH THE LATEST EDITION OF THE INTERNATIONAL RESIDENTIAL CODE. STRUCTURAL STEEL 1.ALL HOT ROLLED STRUCTURAL STEEL W-SHAPES SHALL CONFORM TO ASTM SPECIFICATION A992, GRADE 50. 2.ALL STRUCTURAL STEEL TUBING SHALL CONFORM TO ASTM SPECIFICATION A-500, GRADE B. 3.ALL STRUCTURAL STEEL M-SHAPES, S-SHAPES, CHANNELS, ANGLES, PLATES AND BARS SHALL CONFORM TO ASTM SPECIFICATION A36 UNLESS OTHERWISE SHOWN OR NOTED OTHERWISE. 4.ALL ROUND, SQUARE AND RECTANGULAR HOLLOW STRUCTURAL SHAPES (HSS) SHALL CONFORM TO ASTM A500, GRADE B. 5.ALL STRUCTURAL STEEL PIPE SHALL CONFORM TO ASTM SPECIFICATION A53, GRADE B. 6.ALL ANCHOR RODS SHALL CONFORM TO ASTM SPECIFICATION F1554, GRADE 55. 7.ALL STRUCTURAL STEEL SHALL BE DESIGNED, FABRICATED AND ERECTED IN ACCORDANCE WITH THE LATEST SPECIFICATIONS OF THE AMERICAN INSTITUTE OF STEEL CONSTRUCTION AND THE STEEL JOIST INSTITUTE. 8.ALL STRUCTURAL STEEL BOLTS SHALL CONFORM TO ASTM A325, TYPE I, HEAVY HEX UNLESS OTHERWISE SHOWN OR NOTED. FURNISH HEAVY HEX CARBON-STEEL NUTS PER ASTM A563 AND HARDENED CARBON-STEEL WASHERS PER ASTM F436 AT ALL BOLTED CONNECTIONS, INCLUDING ANCHOR RODS. ANCHOR RODS SHALL BE ASTM A307. 10.ALL BEAMS AND COLUMNS SHALL BE FULL LENGTH WITHOUT SPLICES UNLESS OTHERWISE INDICATED ON PLANS. 11.ALL SHOP AND FIELD WELDS SHALL BE MADE BY WELDERS WHO HAVE BEEN QUALIFIED AND CERTIFIED TO MAKE THE REQUIRED WELDS WITHIN THE PREVIOUS SIX MONTHS IN ACCORDANCE WITH THE LATEST AMERICAN WELDING SOCIETY SPECIFICATIONS A.W.S. D1.1. 12.WELD FILLER METAL SHALL BE E70XX ELECTRODES, UNLESS OTHERWISE SPECIFIED. MINIMUM WELD SIZE SHALL BE 1/4 INCH FILLET WELD, UNLESS OTHERWISE NOTED. STEEL JOISTS SHALL BE FABRICATED IN ACCORDANCE WITH A.W.S. D1.1. 13.ERECTION CONNECTORS SHALL BE PROVIDED IN ORDER TO PROPERLY ALIGN AND BE TRUE AND PLUMB WHEN WELDS ARE MADE. 14.SHOP DRAWINGS SHALL BE PREPARED FOR ALL STRUCTURAL STEEL AND SUBMITTED FOR REVIEW BY ENGINEER. ENGINEERING DRAWINGS SHALL NOT BE REPRODUCED AND USED AS SHOP DRAWINGS. 15.ALL COMPLETE PENETRATION WELDS, BOTH SHOP AND FIELD, SHALL BE MADE UNDER THE OBSERVATION OF A QUALIFIED TESTING LABORATORY INSPECTOR. 16.THE FABRICATOR SHALL SUPPLY BACK UP PLATES AND EXTENSION TABS FOR ALL COMPLETE PENETRATION WELDS. 17.ALL STRUCTURAL STEEL MEMBERS SHALL BE CLEANED IN ACCORDANCE WITH STEEL STRUCTURES PAINTING COUNCIL (SSPC) SP-1 SOLVENT CLEANING. 18.SHOP PAINT ALL STEEL EXCEPT GALVANIZED ITEMS, ITEMS EMBEDDED IN CONCRETE, AND AREA TO BE WELDED, WITH 5 MIL COAT OF PITTSBURGH PPG PITT-GUARD PRIMER AND 3 MIL COAT OF PPG PITTHANE. COLOR TO BE SELECTED BY OWNER. 19.ALL STEEL BEAMS BENEATH PLYWOOD FLOOR OR ROOF DECKS SHALL BE INSTALLED WITH A 2x NAILER AT THE TOP OF THE BEAM. THE WIDTH OF THE NAILER SHALL MATCH THE WIDTH OF THE BEAM AND BE CONNECTED WITH TWO TB1460S SCREWS BY SIMPSON EVERY 6” ON CENTER. FLOOR FRAMING 1.UNLESS NOTED OTHERWISE, ALL LUMBER SHALL BE CLEARLY MARKED SOUTHERN PINE #2 BY THE SPIB. 2.LATERALLY SUPPORT FLOOR JOISTS OR TRUSSES AT THE ENDS BY FULL DEPTH SOLID BLOCKING OR CONTINUOUS RIM BOARD. WHERE CONNECTED TO THE FACE OF A HEADER USE A HANGER SPECIFIED IN THE FACE MOUNT HANGER SCHEDULE. 3.PROVIDE A MINIMUM OF 1.5” OF BEARING FOR ALL JOISTS. 4.WHERE 2x12 FRAMING IS USED, PROVIDE FULL DEPTH BLOCKING OR BRIDGING AT 8' ON CENTER MAXIMUM. 5.FLOOR DECKING SHALL BE 3/4" MINIMUM THICKNESS, TONGUE AND GROOVE, RATED FOR THE SPACING OF THE SUPPORTING JOISTS. 6.AT EXTERIOR DECKS, CONTRACTOR SHALL PROVIDE TREATED LUMBER OR FULLY WEATHERPROOF ALL FRAMING MEMBERS. 7.IF FLOOR BEAMS ARE TO BE DESIGNED BY OTHERS, THE DESIGNER SHALL VERIFY THAT ALL LOADS FROM ROOFS, CEILINGS, AND WALLS ABOVE ARE ADEQUATELY SUPPORTED BY THE FLOOR FRAMING SYSTEM. 8.BEAMS DESIGNED BY OTHERS THAT DIRECTLY OR INDIRECTLY SUPPORT MASONRY VENEER SHALL BE DESIGNED TO LIMIT THE TOTAL LOAD DEFLECTION TO L/600. WALL FRAMING 1.UNLESS OTHERWISE NOTED, ALL STUDS SHALL BE CLEARLY MARKED SOUTHERN PINE #2 BY THE SPIB. 2.END JOINTED LUMBER GRADED BY SPIB MAY BE USED INTERCHANGABLY WITH SOLID SAWN LUMBER OF THE SAME SPECIES AND GRADE. 3.MAXIMUM LATERALLY UNSUPPORTED LENGTHS OF WOOD WALL STUDS FOR THE GIVEN STUD SIZE AND SPACING: SUPPORTING ROOF ONLY 2x4 @ 16” O.C.12'-0” 2x6 @ 24” O.C.14'-0” 2x6 @ 16” O.C. 16'-0” 2x6 @ 12” O.C.18'-0” 2x6 @ 8” O.C.20'-0” SUPPORTING ONE FLOOR AND A ROOF 2x4 @ 16” O.C.10'-0” 2x6 @ 24” O.C.12'-0” 2x6 @ 16” O.C.16'-0” 2x6 @ 12” O.C.18'-0” 2x6 @ 8” O.C.20'-0” SUPPORTING TWO FLOORS AND A ROOF 2x6 @ 24” O.C.10'-0” 2x6 @ 16” O.C.14'-0” 2x6 @ 12” O.C.16'-0” 2x6 @ 8” O.C.18'-0” 4.WOOD STUD WALLS SHALL BE CAPPED WITH A DOUBLE TOP PLATE INSTALLED TO PROVIDE OVERLAPPING AT CORNERS AND INTERSECTIONS WITH BEARING PARTITIONS. 5.ALL WOOD STUD WALLS SHALL BE FULL HEIGHT WITHOUT INTERMEDIATE PLATE LINE UNLESS DETAILED OTHERWISE. 6.BOTTOM PLATES IN CONTACT WITH CONCRETE MUST BE PRESSURE TREATED AND SHALL BE ANCHORED TO THE CONCRETE BY THE FOLLOWING METHODS: EXTERIOR PLATES: 1/2" DIAMETER x 7” EMBEDMENT BOLTS WITH WASHERS AT 6'-0” ON CENTER MAX, OR MASA BY SIMPSON AT 6'-0” ON CENTER MAX. INTERIOR PLATES: 1/2" DIAMETER x 7” EMBEDMENT BOLTS WITH WASHERS AT 6'-0” ON CENTER MAX, OR X-C PAF (2 13/16” LONG) BY HILTI @ 9” ON CENTER MAX. 7.GABLE WALLS SHALL BE BRACED BY CEILING FRAMING AT THE TOP PLATE. PROVIDE BLOCKING BETWEEN CEILING JOISTS. PROVIDE STUDS THAT COMPLY WITH MAXIMUM HEIGHT LISTED IN THESE NOTES. 8.THE CONTINUOUS DOUBLE TOP PLATE MAY BE INTERRUPTED IF NEEDED TO INSTALL THE SPECIFIED HEADER. IF THE TOP PLATE IS INTERRUPTED BY A HEADER, ATTACH THE TOP PLATE TO THE HEADER AT EACH END WITH 3"x12"x0.036" GALVANIZED STEEL PLATE WITH (12)8d NAILS AT EACH SIDE OF THE JOINT. CEILING FRAMING 1.UNLESS NOTED OTHERWISE, ALL LUMBER SHALL BE CLEARLY MARKED SOUTHERN PINE #2 BY THE SPIB. 2.UNLESS NOTED OTHERWISE, CEILING JOISTS SHALL BE 2x6 @ 24” ON CENTER. 3.PROVIDE MINIMUM 1.5” BEARING AT THE ENDS OF ALL JOISTS. WHERE JOISTS FRAME INTO THE SIDE OF A BEAM, USE METAL JOIST HANGERS AS INDICATED IN THE FACE MOUNT HANGER SCHEDULE. 4.PROVIDE BLOCKING BETWEEN CEILING JOISTS AT EXTERIOR WALLS. WHERE THE JOISTS ARE 2X10 OR 2X12, BLOCKING IS REQUIRED AT ALL SUPPORTS. FOR 2X10 FRAMING, PROVIDE FULL DEPTH BLOCKING, DIAGONAL BRIDGING (WOOD OR METAL), OR A CONTINUOUS 1-INCH BY 3-INCH WOOD STRIP NAILED ACROSS THE CEILING JOISTS AT INTERVALS NOT EXCEEDING 8 FEET. FOR 2X12 FRAMING, PROVIDE FULL DEPTH BLOCKING AT INTERVALS NOT EXCEEDING 8 FEET. 5.WHERE CEILING JOISTS ARE PARALLEL TO A NONBEARING WALL, BRACE THE TOP OF THE WALL WITH 2x4 BLOCKING AT 24” ON CENTER BETWEEN JOISTS. ROOF AND RAFTERS 1.UNLESS NOTED OTHERWISE, ALL LUMBER SHALL BE CLEARLY MARKED SOUTHERN PINE #2 BY THE SPIB. 2.FRAMING FOR COMPOSITION SHINGLE OR METAL ROOFS IS DESIGNED ASSUMING THE ROOFING MATERIAL WEIGHS A MAXIMUM OF 5 PSF. CONTACT ENGINEER IF ROOFING MATERIAL EXCEEDS THIS WEIGHT. 3.FRAMING FOR TILE ROOFS IS DESIGNED ASSUMING THE ROOFING MATERIAL WEIGHS A MAXIMUM OF 10 PSF. CONTACT ENGINEER IF ROOFING MATERIAL EXCEEDS THIS WEIGHT. 4.PROVIDE BLOCKING BETWEEN RAFTERS AT EXTERIOR WALLS. FOR 2x12 FRAMING, PROVIDE FULL DEPTH BLOCKING OR BRIDGING AT 8'-0” ON CENTER MAXIMUM. 5.ROOF BRACING SHALL BE INSTALLED SUCH THAT THE SLOPE OF THE BRACE IS BETWEEN VERTICAL AND 45 DEGREES. PROVIDE TWO STUDS BELOW THE BRACE WHERE THE BRACE IS SUPPORTED BY A WALL. IF THE SUPPORTING WALL IS ON AN UPPER LEVEL, PROVIDE STUDS ON ALL LEVELS BELOW TO PROVIDE A CONTINUOUS LOAD PATH TO THE FOUNDATION. 6.AT POINT OF SUPPORT FOR ROOF BRACES, ADEQUATELY BLOCK WALLS AND BEAMS TO PREVENT ROTATION AND HORIZONTAL MOVEMENT. 7.BRACES UP TO 6' MAY BE CONSTRUCTED WITH A SINGLE 2x4. BRACES LONGER THAN 6' AND UP TO 14' MAY BE CONSTRUCTED WITH A 2x4 WITH A 2x4 STIFFBACK. BRACES LONGER THAN 14' AND UP TO 22' MAY BE CONSTRUCTED WITH A 2x6 WITH A 2x6 STIFFBACK. CONTACT ENGINEER IF BRACE LENGTH EXCEEDS 22'. 8.ROOF DECKING SHALL BE MINIMUM 7/16” PLYWOOD OR OSB ATTACHED PER THE FASTENING SCHEDULE. ENGINEERED BEAMS 1.LVL BEAMS (LAMINATED VENEER LUMBER) SHALL HAVE A MINIMUM Fb=2600psi, Fv=285psi, E=2000ksi. 2.PSL BEAMS (PARALLEL STRAND LUMBER) SHALL HAVE A MINIMUM Fb=2900psi, Fv=290psi, E=2000ksi. 3.APB BEAMS (ANTHONY POWER BEAM) SHALL HAVE A MINIMUM Fb=3000psi, Fv=300psi, E=2100ksi. 4.FOR BEAMS BEARING ON STUD WALLS, PROVIDE STUDS DIRECTLY BENEATH THE BEAM. IF THE BEAM IS ON AN UPPER LEVEL, PROVIDE STUDS ON ALL LEVELS BELOW TO PROVIDE A CONTINUOUS LOAD PATH TO THE FOUNDATION. THERE SHALL BE TWO STUDS BELOW BEAMS UP TO 4” WIDE, THREE STUDS BELOW BEAMS UP TO 6” WIDE, AND FOUR STUDS FOR BEAMS UP TO 8” WIDE. 5.ALL BEAMS SHALL BE LATERALLY BRACED AT ALL SUPPORT POINTS. BEAMS WHICH ARE NOT DIRECTLY LOADED BY CEILING JOISTS SHALL HAVE ADDITIONAL LATERAL SUPPORTS AT 1/3 SPAN POINTS. 6.GLU-LAM OR PSL BEAMS MAY BE SUBSTITUED FOR BEAMS INDICATED ON THE DRAWINGS, PROVIDED THAT THEIR DESIGN VALUES MEET OR EXCEED THOSE LISTED ABOVE AND THE WIDTH AND DEPTH MEET OR EXCEED THOSE OF THE SPECIFIED BEAM. LVL BEAMS MAY NOT BE SUBSTITUTED FOR GLU-LAM OR PSL BEAMS UNLESS APPROVED BY THE ENGINEER.DRAWN BY: DETAIL INFO: TX FIRM REG. NO. F-4031 WWW.CRITEXAS.COM DATE SHEET REVISION NOTES SCALE 05/18/23 S6.2 DE T A I L / S P E C S S H E E T T Y P I C A L F R A M I N G FASTENER SCHEDULE FOR STRUCTURAL MEMBERS DESCRIPTION OF BUILDING ELEMENTS NUMBER AND TYPE OF FASTENER SPACING AND LOCATION BLOCKING BETWEEN CEILING JOISTS OR RAFTERS TO TOP PLATE ITEM 4-8d BOX (2 12" x 0.113") OR 3-8d COMMON (2 12" x 0.131"); OR 3-10d BOX (3" x 0.128"); OR 3-3" x 0.131" NAILS 1 TOE NAIL CEILING JOISTS TO TOP PLATE 4-8d BOX (2 12" x 0.113") OR 3-8d COMMON (2 12" x 0.131"); OR 3-10d BOX (3" x 0.128"); OR 3-3" x 0.131" NAILS 2 PER JOIST, TOE NAIL CEILING JOIST NOT ATTACHED TO PARALLEL RAFTER, LAPS OVER PARTITIONS [SEE SECTIONS R802.3.1, R802.3.2 AND TABLE R802.5.1(9)] 4-10d BOX (3" x 0.128"); OR 3-16d COMMON (3 12" x 0.162"); OR 4-3" x 0.131" NAILS 3 FACE NAIL CEILING JOIST ATTACHED TO PARALLEL RAFTER (HEEL JOINT) [SEE SECTIONS R802.3.1, R802.3.2 AND TABLE R802.5.1(9)] TABLE R802.5.1(9)4 FACE NAIL RAFTER OR ROOF TRUSS TO PLATE 3-16d BOX NAILS (3 12" x 0.135"); OR 3-10d COMMON NAILS (3" x 0.148"); OR 4-10d BOX (3" x 0.128"); OR 4-3" x 0.131" NAILS 5 2 TOE NAILS ON ONE SIDE AND 1 TOE NAIL ON OPPOSITE SIDE OF EACH RAFTER OR TRUSS ROOF RAFTERS TO RIDGE, VALLEY OR HIP RAFTERS OR ROOF RAFTER TO MINIMUM 2" RIDGE BEAM 4-16d (3 12" x 0.135"); OR 3-10d COMMON (3 12" x 0.148"); OR 4-10d BOX (3" x 0.128"); OR 4-3" x 0.131" NAILS6 TOE NAIL 3-16d BOX (3 12" x 0.135"); OR 2-16d COMMON (3 12" x 0.162"); OR 3-10d BOX (3" x 0.128"); OR 3-3" x 0.131" NAILS END NAIL ROOF WALL STUD TO STUD (NOT AT BRACED WALL PANELS) 16d COMMON (3 12" x 0.162") 7 10d BOX (3" x 0.128"); OR 3" x 0.131" NAILS 24" O.C. FACE NAIL 16" O.C. FACE NAIL STUD TO STUD AND ABUTTING STUDS AT INTERSECTING WALL CORNERS (AT BRACED WALL PANELS)16d COMMON (3 12" x 0.162") 8 16d BOX (3 12" x 0.135"); OR 3" x 0.131" NAILS 16" O.C. FACE NAIL 12" O.C. FACE NAIL BUILT-UP HEADER (2" TO 2" HEADER WITH 12" SPACER) 16d COMMON (3 12" x 0.162") 9 16" O.C. EACH EDGE FACE NAIL 12" O.C. EACH EDGE FACE NAIL16d BOX (3 12" x 0.135") CONTINUOUS HEADER TO STUD 5-8d BOX (2 12" x 0.113"); OR 4-8d COMMON (2 12" x 0.131"); OR 4-10d BOX (3" x 0.128") 10 TOE NAIL TOP PLATE TO TOP PLATE 16d COMMON (3 12" x 0.162") 11 10d BOX (3" x 0.128"); OR 3" x 0.131" NAILS 16" O.C. FACE NAIL 12" O.C. FACE NAIL DOUBLE TOP PLATE SPLICE12 FACE NAIL ON EACH SIDE OF END JOINT (MINIMUM 24" LAP SPLICE LENGTH EACH SIDE OF END JOINT) 8-16d COMMON (3 12" x 0.162"); OR 12-16d BOX (3 12" x 0.135"); OR 12-10d BOX (3" x 0.128"); OR 12-3" x 0.131" NAILS BOTTOM PLATE TO JOIST, RIM JOIST, BAND JOIST OR BLOCKING (NOT AT BRACED WALL PANELS) 16d COMMON (3 12" x 0.162") 13 16d BOX (3 12" x 0.135"); OR 3" x 0.131" NAILS 16" O.C. FACE NAIL 12" O.C. FACE NAIL BOTTOM PLATE TO JOIST, RIM JOIST, BAND JOIST OR BLOCKING (AT BRACED WALL PANELS) 14 3 EACH 16" O.C. FACE NAIL 2 EACH 16" O.C. FACE NAIL 4 EACH 16" O.C. FACE NAIL 3-16d BOX (3 12" x 0.135"); OR 2-16d COMMON (3 12" x 0.162"); OR 4-3" x 0.131" NAILS TOP OR BOTTOM PLATE TO STUD 4-8d BOX (2 12" x 0.113"); OR 3-16d BOX (3 12" x 0.135"); OR 4-8d COMMON (2 12" x 0.131"); OR 4-10d BOX (3" x 0.128"); OR 4-3" x 0.131" NAILS15 TOE NAIL 3-16d BOX (3 12" x 0.135"); OR 2-16d COMMON (3 12" x 0.162"); OR 3-10d BOX (3" x 0.128"); OR 3-3" x 0.131" NAILS END NAIL TOP PLATES, LAPS AT CORNERS AND INTERSECTIONS16 FACE NAIL 3-10d BOX (3" x 0.128"); OR 2-16d COMMON (3 12" x 0.162"); OR 3-3" x 0.131" NAILS 1" BRACE TO EACH STUD AND PLATE17 FACE NAIL 3-8d BOX (2 12" x 0.113"); OR 2-8d COMMON (2 12" x 0.131"); OR 2-10d BOX (3" x 0.128"); OR 2 STAPLES 1 3 4" JOIST TO SILL, TOP PLATE OR GIRDER18 TOE NAIL 4-8d BOX (2 12" x 0.113"); OR 3-8d COMMON (2 12" x 0.131"); OR 3-10d BOX (3" x 0.128"); OR 3-3" x 0.131" NAILS RIM JOIST, BAND JOIST OR BLOCKING TO SILL OR TOP PLATE (ROOF APPLICATIONS ALSO) 8d BOX (2 12" x 0.113") 19 8d COMMON (2 12" x 0.131"); OR 10d BOX (3" x 0.128"); OR 3" x 0.131" NAILS 4" O.C. TOE NAIL 6" O.C. TOE NAIL 1" x 6" SUBFLOOR OR LESS EACH JOIST FACE NAIL 3-8d BOX (2 12" x 0.113"); OR 2-8d COMMON (2 12" x 0.131"); OR 3-10d BOX (3" x 0.128"); OR 2 STAPLES, 1" CROWN, 16 ga. 1 3 4" LONG 20 FLOOR 2" SUBFLOOR TO JOIST OR GIRDER21 BLIND AND FACE NAIL3-16d BOX (3 12" x 0.135"); OR 2-16d COMMON (3 12" x 0.162") 2" PLANKS (PLANK & BEAM - FLOOR & ROOF)22 AT EACH BEARING, FACE NAIL3-16d BOX (3 12" x 0.135"); OR 2-16d COMMON (3 12" x 0.162") BAND OR RIM JOIST TO JOIST END NAIL 3-16d COMMON (3 12" x 0.162"); OR 4-10d BOX (3" x 0.128"); OR 4-3" x 0.131" NAILS; OR 4-3" x 14 ga. STAPLES, 716" CROWN 23 BUILT-UP GIRDERS AND BEAMS, 2-INCH LUMBER LAYERS REFERENCE DETAIL K24 LEDGER STRIP SUPPORTING JOISTS OR RAFTERS25 AT EACH JOIST OR RAFTER, FACE NAIL 4-16d BOX (3 12" x 0.135"); OR 3-16d COMMON (3 12" x 0.162"); OR 4-10d BOX (3" x 0.128"); OR 4-3" x 0.131" NAILS BRIDGING TO JOIST26 EACH END, TOE NAIL2-10d (3" x 0.128") DESCRIPTION OF BUILDING ELEMENTS NUMBER AND TYPE OF FASTENER SPACING OF FASTENERS ITEM EDGES (INCHES) INTERMEDIATE SUPPORT (INCHES) WOOD STRUCTURAL PANELS, SUBFLOOR, ROOF AND INTERIOR WALL SHEATHING TO FRAMING AND PARTICLEBOARD WALL SHEATHING TO FRAMING [SEE TABLE R602.3(3) FOR WOOD STRUCTURAL PANEL EXTERIOR WALL SHEATHING TO WALL FRAMING 3 8" - 12"27 6d COMMON (2" x 0.113") NAIL (SUBFLOOR, WALL) 8d COMMON (2 12" x 0.131") NAIL (ROOF)6 12f 19 32" - 1"28 8d COMMON (2 12" x 0.131")6 12f 1 18" - 1 14"29 10d COMMON (3" x 0.148") NAIL; OR 8d (2 12" x 0.131") DEFORMED NAIL 6 12 OTHER WALL SHEATHING 12" STRUCTURAL CELLULOSIC FIBERBOARD SHEATHING30 1 12" GALVANIZED ROOFING NAIL, 716" HEAD DIAMETER, OR 1" CROWN STAPLE 16 ga. , 1 14" LONG 3 6 25 32" STRUCTURAL CELLULOSIC FIBERBOARD SHEATHING31 1 3 4" GALVANIZED ROOFING NAIL, 716" HEAD DIAMETER, OR 1" CROWN STAPLE 16 ga. , 1 14" LONG 3 6 12" GYPSUM SHEATHINGd32 1 12" GALVANIZED ROOFING NAIL; STAPLE GALVANIZED, 1 12" LONG; 1 14" SCREWS, TYPE W OR S 7 7 5 8" GYPSUM SHEATHINGd33 1 3 4" GALVANIZED ROOFING NAIL; STAPLE GALVANIZED, 1 5 8" LONG; 1 5 8" SCREWS, TYPE W OR S 7 7 WOOD STRUCTURAL PANELS, COMBINATION SUBFLOOR UNDERLAYMENT TO FRAMING 3 4" AND LESS34 6d DEFORMED (2" x 0.120") NAIL; OR 8d COMMON (2 12" x 0.131") NAIL 6 12 7 8" - 1"35 8d COMMON (2 12" x 0.131") NAIL; OR 8d DEFORMED (2" x 0.120") NAIL 6 12 1 18" - 1 14"36 10d COMMON (3" x 0.148") NAIL; OR 8d DEFORMED (2 12" x 0.120") NAIL 6 12 DRAWN BY: DETAIL INFO: TX FIRM REG. NO. F-4031 WWW.CRITEXAS.COM DATE SHEET REVISION NOTES SCALE 05/18/23 S6.3 DE T A I L / S P E C S S H E E T T Y P I C A L F R A M I N G EX U R B S T U D I O ww w . E X U R B S T U D I O . c O m EX U R B S T U D I O ww w . E X U R B S T U D I O . c O m EX U R B S T U D I O ww w . E X U R B S T U D I O . c O m EX U R B S T U D I O ww w . E X U R B S T U D I O . c O m EX U R B S T U D I O ww w . E X U R B S T U D I O . c O m EX U R B S T U D I O ww w . E X U R B S T U D I O . c O m EX U R B S T U D I O ww w . E X U R B S T U D I O . c O m EX U R B S T U D I O ww w . E X U R B S T U D I O . c O m EX U R B S T U D I O ww w . E X U R B S T U D I O . c O m EX U R B S T U D I O ww w . E X U R B S T U D I O . c O m EX U R B S T U D I O ww w . E X U R B S T U D I O . c O m EX U R B S T U D I O ww w . E X U R B S T U D I O . c O m EX U R B S T U D I O ww w . E X U R B S T U D I O . c O m Alpine, an ITW company 155 Harlem Ave. North Building, 4th Floor Glenview, IL 60025 Phone: (800)326-4102 (314)344-9121 alpineitw.com Site Information:Page 1: Customer: Sweeney Lumber Job Number: TS2207 Job Description: 84 LUMBER Address: 3405 WITT CT Job Engineering Criteria: Design Code: IRC 2021 IntelliVIEW Version: 24.01.01A JRef #: 1YaK94620001 Wind Standard: ASCE710 Wind Speed (mph): 0 Design Loading (psf): 55.00 Building Type: This package contains general notes pages, 26 truss drawing(s) and 2 detail(s). Item Drawing Number Truss Item Drawing Number Truss 1 155.25.1734.36293 F1 2 155.25.1734.56613 F2 3 155.25.1735.06903 F3 4 155.25.1735.08897 F4 5 155.25.1735.10843 F5 6 155.25.1735.12420 F6 7 155.25.1735.13950 F7 8 155.25.1735.15350 F8 9 155.25.1735.17210 F9 10 155.25.1734.38020 F10 11 155.25.1734.39960 F11 12 155.25.1734.42223 F12 13 155.25.1734.44203 F13 14 155.25.1734.46230 F14 15 155.25.1734.47637 F15 16 155.25.1734.49100 F16 17 155.25.1734.50577 F17 18 155.25.1734.51927 F18 19 155.25.1734.54947 F19 20 155.25.1734.58470 F20 21 155.25.1735.00437 F21 22 155.25.1735.02527 F22 23 155.25.1735.03823 F23 24 155.25.1735.05227 F24 25 155.25.1735.18447 KW1 26 155.25.1735.21720 KW2 27 STRBRIBR1014 28 DEFLCAMB1014 #%INDEX?$ $%Lbl:Cover Sheet?$ 06/04/2025 General Notes Truss Design Engineer Scope of Work, Design Assumptions and Design Responsibilities: The design responsibilities assumed in the preparation of these design drawings are those specified in ANSI/TPI 1, Chapter 2; and the National Design Standard for Metal Plate Connected Wood Truss Construction, by the Truss Plate Institute. The truss component designs conform to the applicable provisions of ANSI/TPI 1 and NDS, the National Design Specification for Wood Construction by AWC. The truss component designs are based on the specified loading and dimension information furnished by others to the Truss Design Engineer. The Truss Design Engineer has no duty to independently verify the accuracy or completeness of the information provided by others and may rely on that information without liability. The responsibility for verification of that information remains with others neither employed nor controlled by the Truss Design Engineer. The Truss Design Engineer’s seal and signature on the attached drawings, or cover page listing these drawings, indicates acceptance of professional engineering responsibility solely for the truss component designs and not for the technical information furnished by others which technical information and consequences thereof remain their sole responsibility. The suitability and use of these drawings for any particular structure is the responsibility of the Building Designer in accordance with ANSI/TPI 1 Chapter 2. The Building Designer is responsible for determining that the dimensions and loads for each truss component match those required by the plans and by the actual use of the individual component, and for ascertaining that the loads shown on the drawings meet or exceed applicable building code requirements and any additional factors required in the particular application. Truss components using metal connector plates with integral teeth shall not be placed in environments that will cause the moisture content of the wood in which plates are embedded to exceed 19% and/or cause corrosion of connector plates and other metal fasteners. The Truss Design Engineer shall not be responsible for items beyond the specific scope of the agreed contracted work set forth herein, including but not limited to: verifying the dimensions of the truss component, calculation of any of the truss component design loads, inspection of the truss components before or after installation, the design of temporary or permanent bracing and their attachment required in the roof and/or floor systems, the design of diaphragms or shear walls, the design of load transfer connections to and from diaphragms and shear walls, the design of load transfer to the foundation, the design of connections for truss components to their bearing supports, the design of the bearing supports, installation of the truss components, observation of the truss component installation process, review of truss assembly procedures, sequencing of the truss component installation, construction means and methods, site and/or worker safety in the installation of the truss components and/or its connections. This document may be a high-quality facsimile of the original engineering document which is a digitally signed electronic file with third party authentication. A wet or embossed seal copy of this engineering document is available upon request. Temporary Lateral Restraint and Bracing: Temporary lateral restraint and diagonal bracing shall be installed according to the provisions of BCSI chapters B1, B2, B7 and/or B10 (Building Component Safety Information, by TPI and SBCA), or as specified by the Building Designer or other Registered Design Professional. The required locations for lateral restraint and/or bracing depicted on these drawings are only for the permanent lateral support of the truss members to reduce buckling lengths, and do not apply to and may not be relied upon for the temporary stability of the truss components during their installation. Permanent Lateral Restraint and Bracing: The required locations for lateral restraint or bracing depicted on these drawings are for the permanent lateral support of the truss members to reduce buckling lengths. Permanent lateral support shall be installed according to the provisions of BCSI chapters B3, B7 and/or B10, or as specified by the Building Designer or other Registered Design Professional. These drawings do not depict or specify installation/erection bracing, wind bracing, portal bracing or similar building stability bracing which are parts of the overall building design to be specified, designed, and detailed by the Building Designer. Connector Plate Information: Alpine connector plates are made of ASTM A653 or ASTM A1063 galvanized steel with the following designations, gauges and grades: W=Wave, 20ga, grade 40; H=High Strength, 20ga, grade 60; S=Super Strength, 18ga, grade 60. Information on model code compliance is contained in the ICC Evaluation Service report ESR-1118, available on-line at www.icc-es.org. Bearing Information: The bearing area factor, Cb, is considered for the allowable capacity of solid sawn wood bearings supporting trusses that are located a minimum of 3” from the end of the lumber piece. #%NOSEAL?$ Page 1 of 3 General Notes (continued) Coated Lumber: Coated lumber must be properly re-dried and maintained below 19% or less moisture level through all stages of construction and usage. Coated lumber has no adjustments to lumber properties. Coated lumber may be more brittle than uncoated lumber. Special handling care must be taken to prevent breakage during all handling activities. Refer to manufacturer literature, specifications, and code evaluation reports for restrictions, details, and requirements. Fire Retardant Treated Lumber: Fire retardant treated lumber must be properly re-dried and maintained below 19% or less moisture level through all stages of construction and usage. Fire retardant treated lumber may be more brittle than untreated lumber. Special handling care must be taken to prevent breakage during all handling activities. Key to Terms: Information provided on drawings reflects a summary of the pertinent information required for the truss design. Detailed information on load cases, reactions, member lengths, forces and members requiring permanent lateral support may be found in calculation sheets available upon written request. BCDL = Bottom Chord standard design Dead Load in pounds per square foot. BCLL = Bottom Chord standard design Live Load in pounds per square foot. C = Coated lumber. C-AT = AtTEK coated lumber. C-FX = FX Lumber Guard coated lumber. C -TE = TechWood 4400 coated lumber. CL = Certified lumber. Des Ld = total of TCLL, TCDL, BCLL and BCDL Design Load in pounds per square foot. FRT = Fire Retardant Treated lumber. FRT-BF = Boraflame Fire Retardant Treated lumber FRT-DB = D-Blaze Fire Retardant Treated lumber. FRT-DC = Dricon Fire Retardant Treated lumber. FRT-FP = FirePRO Fire Retardant Treated lumber. FRT-FL = FlamePRO Fire Retardant Treated lumber. FRT-FT = FlameTech Fire Retardant Treated lumber. FRT-ON = OnWood Fire Retardant Treated lumber. FRT-PG = PYRO-GUARD Fire Retardant Treated lumber. FRT-PR = ProWood Fire Retardant Treated lumber. g = green lumber. HORZ(LL) = maximum Horizontal panel point deflection due to Live Load, in inches. HORZ(TL) = maximum Horizontal panel point long term deflection in inches, due to Total Load, including creep adjustment. HPL = additional Horizontal Load added to a truss Piece in pounds per linear foot or pounds. Ic = Incised lumber. FJ = Finger Jointed lumber. L/# = user specified divisor for limiting span/deflection ratio for evaluation of actual L/defl value. L/defl = ratio of Length between bearings, in inches, divided by the vertical Deflection due to creep, in inches, at the referenced panel point. Reported as 999 if greater than or equal to 999. Loc = Location, starting location of left end of bearing or panel point (joint) location of deflection. Max BC CSI = Maximum bending and axial Combined Stress Index for Bottom Chords for all load cases. Max TC CSI = Maximum bending and axial Combined Stress Index for Top Chords for all load cases. Max Web CSI= Maximum bending and axial Combined Stress Index for Webs for all load cases. NCBCLL = Non-Concurrent Bottom Chord design Live Load in pounds per square foot. PL = additional Load applied at a user specified angle on a truss Piece in pounds per linear foot or pounds. PLB = additional vertical load added to a Bottom chord Piece of a truss in pounds per linear foot or pounds PLT = additional vertical load added to a Top chord Piece of a truss in pounds per linear foot or pounds. PP = Panel Point. R = maximum downward design Reaction, in pounds, from all specified gravity load cases, at the indicated location (Loc). -R = maximum upward design Reaction, in pounds, from all specified gravity load cases, at the identified location (Loc). Rh = maximum horizontal design Reaction in either direction, in pounds, from all specified gravity load cases, at the indicated location (Loc). RL = maximum horizontal design Reaction in either direction, in pounds, from all specified non-gravity (wind or seismic) load cases, at the indicated location (Loc). #%NOSEAL?$ Page 2 of 3 General Notes (continued) Key to Terms (continued): Rw = maximum downward design Reaction, in pounds, from all specified non-gravity (wind or seismic) load cases, at the identified location (Loc). TCDL = Top Chord standard design Dead Load in pounds per square foot. TCLL = Top Chord standard design Live Load in pounds per square foot. U = maximum Upward design reaction, in pounds, from all specified non-gravity (wind or seismic) load cases, at the indicated location (Loc). VERT(CL) = maximum Vertical panel point deflection in inches due to Live Load and Creep Component of Dead Load in inches. VERT(CTL) = maximum Vertical panel point deflection ratios due to Live Load and Creep Component of Dead Load, and maximum long term Vertical panel point deflection in inches due to Total load, including creep adjustment. VERT(LL) = maximum Vertical panel point deflection in inches due to Live Load. VERT(TL) = maximum Vertical panel point long term deflection in inches due to Total load, including creep adjustment. W = Width of non-hanger bearing, in inches. Refer to ASCE-7 for Wind and Seismic abbreviations. Uppercase Acronyms not explained above are as defined in TPI 1. References: 1. AWC: American Wood Council; 222 Catoctin Circle SE, Suite 201; Leesburg, VA 20175; www.awc.org. 2. ICC: International Code Council; www.iccsafe.org. 3. Alpine, a division of ITW Building Components Group Inc.: 155 Harlem Ave, North Building, 4th Floor, Glenview, IL 60025; www.alpineitw.com. 4. TPI: Truss Plate Institute, 2670 Crain Highway, Suite 203, Waldorf, MD 20601; www.tpinst.org. 5. SBCA: Wood Truss Council of America, 6300 Enterprise Lane, Madison, WI 53719; www. sbcacomponents.com #%NOSEAL?$ Page 3 of 3 **WARNING**READ AND FOLLOW ALL NOTES ON THIS DRAW ING! **IMPORTANT**FURNISH THIS DRAW ING TO ALL CONTRACTORS INCLUDING THE INSTALLERSTrusses require extreme care in fabricating, handling, shipping, installing and bracing. Refer to and follow the latest edition of BCSI (BuildingComponent Safety Information, by TPI and SBCA) for safety practices prior to performing these functions. Installers shall provide temporarybracing per BCSI. Unless noted otherwise, top chord shall have properly attached structural sheathing and bottom chord shall have a properlyattached rigid ceiling. Locations shown for permanent lateral restraint of webs shall have continuous lateral restraint (CLR), installed withdiagonal bracing installed on the CLR per BCSI sections B3, B7, or B10, as applicable. Apply plates to each face of truss and position asshown above and on the Joint Details, unless noted otherwise. Refer to drawings 160A-Z for standard plate positions. Refer to job's GeneralNotes page for additional information.Alpine, a division of ITW Building Components Group Inc. shall not be responsible for any deviation from this drawing, any failure to build thetruss in conformance with ANSI/TPI 1, or for handling, shipping, installation and bracing of trusses. A seal on this drawing or cover pagelisting this drawing, indicates acceptance of professional engineering responsibility solely for the design shown. The suitability and use of thisdrawing for any structure is the responsibility of the Building Designer per ANSI/TPI 1 Sec.2. For more information see these web sites: Alpine: alpineitw.com; TPI: tpinst.org; SBCA: sbcacomponents.com; ICC: iccsafe.org; AWC: awc.org 155 Harlem Ave North Building, 4th Floor Glenview, IL 60025 Lumber Top chord: 4x2 SP #2; Bot chord: 4x2 SP #2; Webs: 4x2 SP #3; Loading Bottom chord checked for 10.00 psf non-concurrent live load. Additional Notes + 2x6 continuous strongback. See detail STRBRIBR1014 for bracing and bridging recommendations. Truss must be installed as shown with top chord up. Maximum Reactions (lbs) Gravity Non-Gravity Loc R+/ R-/ Rh / Rw / U / RL R 865 /-/-/-/-/- J 865 /-/-/-/-/- R Brg Wid = 3.5 Min Req =1.5 (Truss) J Brg Wid = 3.5 Min Req =1.5 (Truss) Bearings R & J are a rigid surface. Members not listed have forces less than 375# Maximum Top Chord Forces Per Ply (lbs) Chords Tens.Comp. A - B 0 -633 B - C 0 -1588 C - D 0 -2060 D - E 0 -2139 Chords Tens.Comp. E - F 0 -2131 F - G 0 -1576 G - H 0 -637 Maximum Bot Chord Forces Per Ply (lbs) Chords Tens.Comp. Q - P 1224 0 P - O 1931 0 O - N 2141 0 Chords Tens.Comp. N - M 2139 0 M - L 1918 0 L - K 1227 0 Maximum Web Forces Per Ply (lbs) Webs Tens.Comp. S - R 0 -865 A - S 0 -848 A - Q 977 0 Q - B 0 -938 B - P 577 0 P - C 0 -546 M - F 505 0 Webs Tens.Comp. F - L 0 -543 L - G 555 0 G - K 0 -937 K - H 982 0 H - I 0 -850 I - J 0 -855 Loading Criteria (psf) TCLL:40.00 TCDL:10.00 BCLL:0.00 BCDL:5.00 Des Ld:55.00 NCBCLL:10.00 Soffit:2.00 Load Duration: 1.00 Spacing: 24.0 " Wind Criteria Wind Std:NA Speed:NA mph Enclosure: NA Category: NA EXP: NA Kzt: NA Mean Height: NA ft TCDL: NA psf BCDL: NA psf MWFRS Parallel Dist: NA C&C Dist a: NA Loc. from endwall: NA I: NA GCpi: NA Wind Duration: NA Snow Criteria (Pg,Pf in PSF) Pg: NA Ct: NA CAT: NA Pf: NA Ce: NA Lu: NA Cs: NA Snow Duration: NA Building Code: IRC 2021 TPI Std:2014 Rep Fac: Yes FT/RT:12(0)/10(0) Plate Type(s): WAVE Defl/CSI Criteria PP Deflection in loc L/defl L/# VERT(LL):0.160 D 999 360 VERT(CL):0.211 D 885 240 HORZ(LL):0.029 B - - HORZ(TL):0.041 B - - Creep Factor: 2.0 Max TC CSI:0.588 Max BC CSI:0.884 Max Web CSI:0.468 VIEW Ver: 24.01.01A.0510.10 Job Number:TS2207 84 LUMBER Truss Label:F1 Ply: 1 Qty:6 SEQN:120285 SY42 FROM: SC Cust: R 9462 JRef:1YaK94620001 T84 DrwNo:155.25.1734.36293 /BM 06/04/2025 3"12 15'11"8 3"2'6" (TYP) 1'3"12 3" 7'10"8 7'10"8 9'4" 1'5"8 15'11"8 6'7"8 1'8"+ A B C D E F G H I JKLMNOPQR S 1X34X4 2X4 4X4 3X4 3X3 3X3 3X3 3X3 1X3 1X3 3X3 3X3 3X3 3X3 4X4 4X4 2X4 1X3 **WARNING**READ AND FOLLOW ALL NOTES ON THIS DRAW ING! **IMPORTANT**FURNISH THIS DRAW ING TO ALL CONTRACTORS INCLUDING THE INSTALLERSTrusses require extreme care in fabricating, handling, shipping, installing and bracing. Refer to and follow the latest edition of BCSI (BuildingComponent Safety Information, by TPI and SBCA) for safety practices prior to performing these functions. Installers shall provide temporarybracing per BCSI. Unless noted otherwise, top chord shall have properly attached structural sheathing and bottom chord shall have a properlyattached rigid ceiling. Locations shown for permanent lateral restraint of webs shall have continuous lateral restraint (CLR), installed withdiagonal bracing installed on the CLR per BCSI sections B3, B7, or B10, as applicable. Apply plates to each face of truss and position asshown above and on the Joint Details, unless noted otherwise. Refer to drawings 160A-Z for standard plate positions. Refer to job's GeneralNotes page for additional information.Alpine, a division of ITW Building Components Group Inc. shall not be responsible for any deviation from this drawing, any failure to build thetruss in conformance with ANSI/TPI 1, or for handling, shipping, installation and bracing of trusses. A seal on this drawing or cover pagelisting this drawing, indicates acceptance of professional engineering responsibility solely for the design shown. The suitability and use of thisdrawing for any structure is the responsibility of the Building Designer per ANSI/TPI 1 Sec.2. For more information see these web sites: Alpine: alpineitw.com; TPI: tpinst.org; SBCA: sbcacomponents.com; ICC: iccsafe.org; AWC: awc.org 155 Harlem Ave North Building, 4th Floor Glenview, IL 60025 Lumber Top chord: 4x2 SP #2; Bot chord: 4x2 SP #2; Webs: 4x2 SP #3; Loading Bottom chord checked for 10.00 psf non-concurrent live load. Additional Notes + 2x6 continuous strongback. See detail STRBRIBR1014 for bracing and bridging recommendations. Truss must be installed as shown with top chord up. Maximum Reactions (lbs) Gravity Non-Gravity Loc R+/ R-/ Rh / Rw / U / RL R 865 /-/-/-/-/- J 865 /-/-/-/-/- R Brg Wid = 3.5 Min Req =1.5 (Truss) J Brg Wid = 3.5 Min Req =1.5 (Truss) Bearings R & J are a rigid surface. Members not listed have forces less than 375# Maximum Top Chord Forces Per Ply (lbs) Chords Tens.Comp. A - B 0 -633 B - C 0 -1588 C - D 0 -2060 D - E 0 -2139 Chords Tens.Comp. E - F 0 -2131 F - G 0 -1576 G - H 0 -637 Maximum Bot Chord Forces Per Ply (lbs) Chords Tens.Comp. Q - P 1224 0 P - O 1931 0 O - N 2141 0 Chords Tens.Comp. N - M 2139 0 M - L 1918 0 L - K 1227 0 Maximum Web Forces Per Ply (lbs) Webs Tens.Comp. S - R 0 -865 A - S 0 -848 A - Q 977 0 Q - B 0 -938 B - P 577 0 P - C 0 -546 M - F 505 0 Webs Tens.Comp. F - L 0 -543 L - G 555 0 G - K 0 -937 K - H 982 0 H - I 0 -850 I - J 0 -855 Loading Criteria (psf) TCLL:40.00 TCDL:10.00 BCLL:0.00 BCDL:5.00 Des Ld:55.00 NCBCLL:10.00 Soffit:2.00 Load Duration: 1.00 Spacing: 24.0 " Wind Criteria Wind Std:NA Speed:NA mph Enclosure: NA Category: NA EXP: NA Kzt: NA Mean Height: NA ft TCDL: NA psf BCDL: NA psf MWFRS Parallel Dist: NA C&C Dist a: NA Loc. from endwall: NA I: NA GCpi: NA Wind Duration: NA Snow Criteria (Pg,Pf in PSF) Pg: NA Ct: NA CAT: NA Pf: NA Ce: NA Lu: NA Cs: NA Snow Duration: NA Building Code: IRC 2021 TPI Std:2014 Rep Fac: Yes FT/RT:12(0)/10(0) Plate Type(s): WAVE Defl/CSI Criteria PP Deflection in loc L/defl L/# VERT(LL):0.160 D 999 360 VERT(CL):0.211 D 885 240 HORZ(LL):0.029 B - - HORZ(TL):0.041 B - - Creep Factor: 2.0 Max TC CSI:0.588 Max BC CSI:0.884 Max Web CSI:0.468 VIEW Ver: 24.01.01A.0510.10 Job Number:TS2207 84 LUMBER Truss Label:F1 Ply: 1 Qty:6 SEQN:120285 SY42 FROM: SC Cust: R 9462 JRef:1YaK94620001 T84 DrwNo:155.25.1734.36293 /BM 06/04/2025 3"12 15'11"8 3"2'6" (TYP) 1'3"12 3" 7'10"8 7'10"8 9'4" 1'5"8 15'11"8 6'7"8 1'8"+ A B C D E F G H I JKLMNOPQR S 1X34X4 2X4 4X4 3X4 3X3 3X3 3X3 3X3 1X3 1X3 3X3 3X3 3X3 3X3 4X4 4X4 2X4 1X3 $%Lbl:F1?$ 06/04/2025 **WARNING**READ AND FOLLOW ALL NOTES ON THIS DRAW ING! **IMPORTANT**FURNISH THIS DRAW ING TO ALL CONTRACTORS INCLUDING THE INSTALLERSTrusses require extreme care in fabricating, handling, shipping, installing and bracing. Refer to and follow the latest edition of BCSI (BuildingComponent Safety Information, by TPI and SBCA) for safety practices prior to performing these functions. Installers shall provide temporarybracing per BCSI. Unless noted otherwise, top chord shall have properly attached structural sheathing and bottom chord shall have a properlyattached rigid ceiling. Locations shown for permanent lateral restraint of webs shall have continuous lateral restraint (CLR), installed withdiagonal bracing installed on the CLR per BCSI sections B3, B7, or B10, as applicable. Apply plates to each face of truss and position asshown above and on the Joint Details, unless noted otherwise. Refer to drawings 160A-Z for standard plate positions. Refer to job's GeneralNotes page for additional information.Alpine, a division of ITW Building Components Group Inc. shall not be responsible for any deviation from this drawing, any failure to build thetruss in conformance with ANSI/TPI 1, or for handling, shipping, installation and bracing of trusses. A seal on this drawing or cover pagelisting this drawing, indicates acceptance of professional engineering responsibility solely for the design shown. The suitability and use of thisdrawing for any structure is the responsibility of the Building Designer per ANSI/TPI 1 Sec.2. For more information see these web sites: Alpine: alpineitw.com; TPI: tpinst.org; SBCA: sbcacomponents.com; ICC: iccsafe.org; AWC: awc.org 155 Harlem Ave North Building, 4th Floor Glenview, IL 60025 Lumber Top chord: 4x2 SP SS; Bot chord: 4x2 SP #2; Webs: 4x2 SP #3; Special Loads ------(Lumber Dur.Fac.=1.00 / Plate Dur.Fac.=1.00) TC: From 650 plf at 0.12 to 650 plf at 12.12 BC: From 10 plf at 0.00 to 10 plf at 12.12 TC: 400 lb Conc. Load at 4.12 Plating Notes All plates are 3X6 except as noted. Loading Bottom chord checked for 10.00 psf non-concurrent live load. Additional Notes See detail STRBRIBR1014 for bracing and bridging recommendations. Truss must be installed as shown with top chord up. Maximum Reactions (lbs) Gravity Non-Gravity Loc R+/ R-/ Rh / Rw / U / RL P 1734 /-/-/-/-/- M 4454 /-/-/-/-/- H 2146 /-/-/-/-/- P Brg Wid = 3.5 Min Req =1.5 (Truss) M Brg Wid = 3.5 Min Req =1.9 (Truss) H Brg Wid = 3.5 Min Req =1.5 (Truss) Bearings P, M, & H are a rigid surface. Members not listed have forces less than 375# Maximum Top Chord Forces Per Ply (lbs) Chords Tens.Comp. A - B 0 -912 B - C 0 -1027 C - D 0 -1027 Chords Tens.Comp. D - E 0 -959 E - F 0 -2136 F - G 0 -1132 Maximum Bot Chord Forces Per Ply (lbs) Chords Tens.Comp. O - N 1757 0 L - K 2132 0 Chords Tens.Comp. K - J 2136 0 J - I 2141 0 Maximum Web Forces Per Ply (lbs) Webs Tens.Comp. Q - P 0 -1730 A - Q 0 -1679 A - O 1344 0 O - B 0 -1276 B - N 0 -1173 C - N 0 -689 N - D 1854 0 Webs Tens.Comp. D - M 0 -4219 D - L 1718 0 L - E 0 -1790 F - I 0 -1525 I - G 1608 0 H - G 399 -5 G - H 0 -2522 Loading Criteria (psf) TCLL:40.00 TCDL:10.00 BCLL:0.00 BCDL:5.00 Des Ld:55.00 NCBCLL:10.00 Soffit:2.00 Load Duration: 1.00 Spacing: 24.0 " Wind Criteria Wind Std:NA Speed:NA mph Enclosure: NA Category: NA EXP: NA Kzt: NA Mean Height: NA ft TCDL: NA psf BCDL: NA psf MWFRS Parallel Dist: NA C&C Dist a: NA Loc. from endwall: NA I: NA GCpi: NA Wind Duration: NA Snow Criteria (Pg,Pf in PSF) Pg: NA Ct: NA CAT: NA Pf: NA Ce: NA Lu: NA Cs: NA Snow Duration: NA Building Code: IRC 2021 TPI Std:2014 Rep Fac: Varies by Ld Case FT/RT:12(0)/10(0) Plate Type(s): WAVE Defl/CSI Criteria PP Deflection in loc L/defl L/# VERT(LL):0.063 F 999 360 VERT(CL):0.084 F 906 240 HORZ(LL):0.007 H - - HORZ(TL):0.010 H - - Creep Factor: 2.0 Max TC CSI:0.797 Max BC CSI:0.598 Max Web CSI:0.580 VIEW Ver: 24.01.01A.0510.10 Job Number:TS2207 84 LUMBER Truss Label:F2 Ply: 1 Qty:3 SEQN:120287 SY42 FROM: SC Cust: R 9462 JRef:1YaK94620001 T85 DrwNo:155.25.1734.56613 /BM 06/04/2025 3"12 5'6"6'7"8 3"2'6" (TYP) 1'4"8 3"3" 12'1"8 4'2"4 4'2"4 4'4"6 2"2 5'6" 1'1"10 8'3" 2'9" 9'3" 1' 10'7"8 1'4"8 10'9"11 2"3 12'1"8 1'3"13 1'8" 1"8 A B C D E F G HIJKLMNOP Q 1X34X6 3X6 5X6 3X6 6X8 6X12 5X6 6X6 4X6 4X6 6X6 6X6 3X6 **WARNING**READ AND FOLLOW ALL NOTES ON THIS DRAW ING! **IMPORTANT**FURNISH THIS DRAW ING TO ALL CONTRACTORS INCLUDING THE INSTALLERSTrusses require extreme care in fabricating, handling, shipping, installing and bracing. Refer to and follow the latest edition of BCSI (BuildingComponent Safety Information, by TPI and SBCA) for safety practices prior to performing these functions. Installers shall provide temporarybracing per BCSI. Unless noted otherwise, top chord shall have properly attached structural sheathing and bottom chord shall have a properlyattached rigid ceiling. Locations shown for permanent lateral restraint of webs shall have continuous lateral restraint (CLR), installed withdiagonal bracing installed on the CLR per BCSI sections B3, B7, or B10, as applicable. Apply plates to each face of truss and position asshown above and on the Joint Details, unless noted otherwise. Refer to drawings 160A-Z for standard plate positions. Refer to job's GeneralNotes page for additional information.Alpine, a division of ITW Building Components Group Inc. shall not be responsible for any deviation from this drawing, any failure to build thetruss in conformance with ANSI/TPI 1, or for handling, shipping, installation and bracing of trusses. A seal on this drawing or cover pagelisting this drawing, indicates acceptance of professional engineering responsibility solely for the design shown. The suitability and use of thisdrawing for any structure is the responsibility of the Building Designer per ANSI/TPI 1 Sec.2. For more information see these web sites: Alpine: alpineitw.com; TPI: tpinst.org; SBCA: sbcacomponents.com; ICC: iccsafe.org; AWC: awc.org 155 Harlem Ave North Building, 4th Floor Glenview, IL 60025 Lumber Top chord: 4x2 SP SS; Bot chord: 4x2 SP #2; Webs: 4x2 SP #3; Special Loads ------(Lumber Dur.Fac.=1.00 / Plate Dur.Fac.=1.00) TC: From 650 plf at 0.12 to 650 plf at 12.12 BC: From 10 plf at 0.00 to 10 plf at 12.12 TC: 400 lb Conc. Load at 4.12 Plating Notes All plates are 3X6 except as noted. Loading Bottom chord checked for 10.00 psf non-concurrent live load. Additional Notes See detail STRBRIBR1014 for bracing and bridging recommendations. Truss must be installed as shown with top chord up. Maximum Reactions (lbs) Gravity Non-Gravity Loc R+/ R-/ Rh / Rw / U / RL P 1734 /-/-/-/-/- M 4454 /-/-/-/-/- H 2146 /-/-/-/-/- P Brg Wid = 3.5 Min Req =1.5 (Truss) M Brg Wid = 3.5 Min Req =1.9 (Truss) H Brg Wid = 3.5 Min Req =1.5 (Truss) Bearings P, M, & H are a rigid surface. Members not listed have forces less than 375# Maximum Top Chord Forces Per Ply (lbs) Chords Tens.Comp. A - B 0 -912 B - C 0 -1027 C - D 0 -1027 Chords Tens.Comp. D - E 0 -959 E - F 0 -2136 F - G 0 -1132 Maximum Bot Chord Forces Per Ply (lbs) Chords Tens.Comp. O - N 1757 0 L - K 2132 0 Chords Tens.Comp. K - J 2136 0 J - I 2141 0 Maximum Web Forces Per Ply (lbs) Webs Tens.Comp. Q - P 0 -1730 A - Q 0 -1679 A - O 1344 0 O - B 0 -1276 B - N 0 -1173 C - N 0 -689 N - D 1854 0 Webs Tens.Comp. D - M 0 -4219 D - L 1718 0 L - E 0 -1790 F - I 0 -1525 I - G 1608 0 H - G 399 -5 G - H 0 -2522 Loading Criteria (psf) TCLL:40.00 TCDL:10.00 BCLL:0.00 BCDL:5.00 Des Ld:55.00 NCBCLL:10.00 Soffit:2.00 Load Duration: 1.00 Spacing: 24.0 " Wind Criteria Wind Std:NA Speed:NA mph Enclosure: NA Category: NA EXP: NA Kzt: NA Mean Height: NA ft TCDL: NA psf BCDL: NA psf MWFRS Parallel Dist: NA C&C Dist a: NA Loc. from endwall: NA I: NA GCpi: NA Wind Duration: NA Snow Criteria (Pg,Pf in PSF) Pg: NA Ct: NA CAT: NA Pf: NA Ce: NA Lu: NA Cs: NA Snow Duration: NA Building Code: IRC 2021 TPI Std:2014 Rep Fac: Varies by Ld Case FT/RT:12(0)/10(0) Plate Type(s): WAVE Defl/CSI Criteria PP Deflection in loc L/defl L/# VERT(LL):0.063 F 999 360 VERT(CL):0.084 F 906 240 HORZ(LL):0.007 H - - HORZ(TL):0.010 H - - Creep Factor: 2.0 Max TC CSI:0.797 Max BC CSI:0.598 Max Web CSI:0.580 VIEW Ver: 24.01.01A.0510.10 Job Number:TS2207 84 LUMBER Truss Label:F2 Ply: 1 Qty:3 SEQN:120287 SY42 FROM: SC Cust: R 9462 JRef:1YaK94620001 T85 DrwNo:155.25.1734.56613 /BM 06/04/2025 3"12 5'6"6'7"8 3"2'6" (TYP) 1'4"8 3"3" 12'1"8 4'2"4 4'2"4 4'4"6 2"2 5'6" 1'1"10 8'3" 2'9" 9'3" 1' 10'7"8 1'4"8 10'9"11 2"3 12'1"8 1'3"13 1'8" 1"8 A B C D E F G HIJKLMNOP Q 1X34X6 3X6 5X6 3X6 6X8 6X12 5X6 6X6 4X6 4X6 6X6 6X6 3X6 $%Lbl:F2?$ 06/04/2025 **WARNING**READ AND FOLLOW ALL NOTES ON THIS DRAW ING! **IMPORTANT**FURNISH THIS DRAW ING TO ALL CONTRACTORS INCLUDING THE INSTALLERSTrusses require extreme care in fabricating, handling, shipping, installing and bracing. Refer to and follow the latest edition of BCSI (BuildingComponent Safety Information, by TPI and SBCA) for safety practices prior to performing these functions. Installers shall provide temporarybracing per BCSI. Unless noted otherwise, top chord shall have properly attached structural sheathing and bottom chord shall have a properlyattached rigid ceiling. Locations shown for permanent lateral restraint of webs shall have continuous lateral restraint (CLR), installed withdiagonal bracing installed on the CLR per BCSI sections B3, B7, or B10, as applicable. Apply plates to each face of truss and position asshown above and on the Joint Details, unless noted otherwise. Refer to drawings 160A-Z for standard plate positions. Refer to job's GeneralNotes page for additional information.Alpine, a division of ITW Building Components Group Inc. shall not be responsible for any deviation from this drawing, any failure to build thetruss in conformance with ANSI/TPI 1, or for handling, shipping, installation and bracing of trusses. A seal on this drawing or cover pagelisting this drawing, indicates acceptance of professional engineering responsibility solely for the design shown. The suitability and use of thisdrawing for any structure is the responsibility of the Building Designer per ANSI/TPI 1 Sec.2. For more information see these web sites: Alpine: alpineitw.com; TPI: tpinst.org; SBCA: sbcacomponents.com; ICC: iccsafe.org; AWC: awc.org 155 Harlem Ave North Building, 4th Floor Glenview, IL 60025 Lumber Top chord: 4x2 SP #2; Bot chord: 4x2 SP #2; Webs: 4x2 SP #3; Loading Bottom chord checked for 10.00 psf non-concurrent live load. Additional Notes + 2x6 continuous strongback. See detail STRBRIBR1014 for bracing and bridging recommendations. Truss must be installed as shown with top chord up. Maximum Reactions (lbs) Gravity Non-Gravity Loc R+/ R-/ Rh / Rw / U / RL U 221 /-/-/-/-/- R 945 /-/-/-/-/- K 651 /-/-/-/-/- U Brg Wid = 3.5 Min Req =1.5 (Truss) R Brg Wid = 3.5 Min Req =1.5 (Truss) K Brg Wid = 3.5 Min Req =1.5 (Truss) Bearings U, R, & K are a rigid surface. Members not listed have forces less than 375# Maximum Top Chord Forces Per Ply (lbs) Chords Tens.Comp. E - F 0 -986 F - G 0 -1166 Chords Tens.Comp. G - H 0 -1021 H - I 0 -443 Maximum Bot Chord Forces Per Ply (lbs) Chords Tens.Comp. Q - P 789 0 P - O 1165 0 O - N 1166 0 Chords Tens.Comp. N - M 1166 0 M - L 853 0 Maximum Web Forces Per Ply (lbs) Webs Tens.Comp. D - R 0 -914 D - Q 702 0 Q - E 0 -668 H - L 0 -651 Webs Tens.Comp. L - I 685 0 I - J 0 -623 J - K 0 -632 Loading Criteria (psf) TCLL:40.00 TCDL:10.00 BCLL:0.00 BCDL:5.00 Des Ld:55.00 NCBCLL:10.00 Soffit:2.00 Load Duration: 1.00 Spacing: 24.0 " Wind Criteria Wind Std:NA Speed:NA mph Enclosure: NA Category: NA EXP: NA Kzt: NA Mean Height: NA ft TCDL: NA psf BCDL: NA psf MWFRS Parallel Dist: NA C&C Dist a: NA Loc. from endwall: NA I: NA GCpi: NA Wind Duration: NA Snow Criteria (Pg,Pf in PSF) Pg: NA Ct: NA CAT: NA Pf: NA Ce: NA Lu: NA Cs: NA Snow Duration: NA Building Code: IRC 2021 TPI Std:2014 Rep Fac: Yes FT/RT:12(0)/10(0) Plate Type(s): WAVE Defl/CSI Criteria PP Deflection in loc L/defl L/# VERT(LL):0.058 G 999 360 VERT(CL):0.086 G 999 240 HORZ(LL):0.010 L - - HORZ(TL):0.016 B - - Creep Factor: 2.0 Max TC CSI:0.487 Max BC CSI:0.515 Max Web CSI:0.334 VIEW Ver: 24.01.01A.0510.10 Job Number:TS2207 84 LUMBER Truss Label:F3 Ply: 1 Qty:3 SEQN:120289 SY42 FROM: SC Cust: R 9462 JRef:1YaK94620001 T86 DrwNo:155.25.1735.06903 /BM 06/04/2025 3"12 4'11'11"8 3" 1'3"12 1'3"12 3" 2'6" (TYP) 3" 15'11"8 1'7"8 1'7"8 2'6" 10"8 4' 1'6" 9'3" 5'3" 10'7" 1'4" 15'11"8 5'4"8 1'8" + A B C D E F G H I J KLMNOPQRSTU 1X33X3 2X4 3X3 1X3 1X3 3X3 4X6 2X4 4X4 3X3 3X3 3X3 1X3 1X3 3X3 3X3 3X3 3X4 3X4 2X4 1X3 **WARNING**READ AND FOLLOW ALL NOTES ON THIS DRAW ING! **IMPORTANT**FURNISH THIS DRAW ING TO ALL CONTRACTORS INCLUDING THE INSTALLERSTrusses require extreme care in fabricating, handling, shipping, installing and bracing. Refer to and follow the latest edition of BCSI (BuildingComponent Safety Information, by TPI and SBCA) for safety practices prior to performing these functions. Installers shall provide temporarybracing per BCSI. Unless noted otherwise, top chord shall have properly attached structural sheathing and bottom chord shall have a properlyattached rigid ceiling. Locations shown for permanent lateral restraint of webs shall have continuous lateral restraint (CLR), installed withdiagonal bracing installed on the CLR per BCSI sections B3, B7, or B10, as applicable. Apply plates to each face of truss and position asshown above and on the Joint Details, unless noted otherwise. Refer to drawings 160A-Z for standard plate positions. Refer to job's GeneralNotes page for additional information.Alpine, a division of ITW Building Components Group Inc. shall not be responsible for any deviation from this drawing, any failure to build thetruss in conformance with ANSI/TPI 1, or for handling, shipping, installation and bracing of trusses. A seal on this drawing or cover pagelisting this drawing, indicates acceptance of professional engineering responsibility solely for the design shown. The suitability and use of thisdrawing for any structure is the responsibility of the Building Designer per ANSI/TPI 1 Sec.2. For more information see these web sites: Alpine: alpineitw.com; TPI: tpinst.org; SBCA: sbcacomponents.com; ICC: iccsafe.org; AWC: awc.org 155 Harlem Ave North Building, 4th Floor Glenview, IL 60025 Lumber Top chord: 4x2 SP #2; Bot chord: 4x2 SP #2; Webs: 4x2 SP #3; Loading Bottom chord checked for 10.00 psf non-concurrent live load. Additional Notes + 2x6 continuous strongback. See detail STRBRIBR1014 for bracing and bridging recommendations. Truss must be installed as shown with top chord up. Maximum Reactions (lbs) Gravity Non-Gravity Loc R+/ R-/ Rh / Rw / U / RL U 221 /-/-/-/-/- R 945 /-/-/-/-/- K 651 /-/-/-/-/- U Brg Wid = 3.5 Min Req =1.5 (Truss) R Brg Wid = 3.5 Min Req =1.5 (Truss) K Brg Wid = 3.5 Min Req =1.5 (Truss) Bearings U, R, & K are a rigid surface. Members not listed have forces less than 375# Maximum Top Chord Forces Per Ply (lbs) Chords Tens.Comp. E - F 0 -986 F - G 0 -1166 Chords Tens.Comp. G - H 0 -1021 H - I 0 -443 Maximum Bot Chord Forces Per Ply (lbs) Chords Tens.Comp. Q - P 789 0 P - O 1165 0 O - N 1166 0 Chords Tens.Comp. N - M 1166 0 M - L 853 0 Maximum Web Forces Per Ply (lbs) Webs Tens.Comp. D - R 0 -914 D - Q 702 0 Q - E 0 -668 H - L 0 -651 Webs Tens.Comp. L - I 685 0 I - J 0 -623 J - K 0 -632 Loading Criteria (psf) TCLL:40.00 TCDL:10.00 BCLL:0.00 BCDL:5.00 Des Ld:55.00 NCBCLL:10.00 Soffit:2.00 Load Duration: 1.00 Spacing: 24.0 " Wind Criteria Wind Std:NA Speed:NA mph Enclosure: NA Category: NA EXP: NA Kzt: NA Mean Height: NA ft TCDL: NA psf BCDL: NA psf MWFRS Parallel Dist: NA C&C Dist a: NA Loc. from endwall: NA I: NA GCpi: NA Wind Duration: NA Snow Criteria (Pg,Pf in PSF) Pg: NA Ct: NA CAT: NA Pf: NA Ce: NA Lu: NA Cs: NA Snow Duration: NA Building Code: IRC 2021 TPI Std:2014 Rep Fac: Yes FT/RT:12(0)/10(0) Plate Type(s): WAVE Defl/CSI Criteria PP Deflection in loc L/defl L/# VERT(LL):0.058 G 999 360 VERT(CL):0.086 G 999 240 HORZ(LL):0.010 L - - HORZ(TL):0.016 B - - Creep Factor: 2.0 Max TC CSI:0.487 Max BC CSI:0.515 Max Web CSI:0.334 VIEW Ver: 24.01.01A.0510.10 Job Number:TS2207 84 LUMBER Truss Label:F3 Ply: 1 Qty:3 SEQN:120289 SY42 FROM: SC Cust: R 9462 JRef:1YaK94620001 T86 DrwNo:155.25.1735.06903 /BM 06/04/2025 3"12 4'11'11"8 3" 1'3"12 1'3"12 3" 2'6" (TYP) 3" 15'11"8 1'7"8 1'7"8 2'6" 10"8 4' 1'6" 9'3" 5'3" 10'7" 1'4" 15'11"8 5'4"8 1'8" + A B C D E F G H I J KLMNOPQRSTU 1X33X3 2X4 3X3 1X3 1X3 3X3 4X6 2X4 4X4 3X3 3X3 3X3 1X3 1X3 3X3 3X3 3X3 3X4 3X4 2X4 1X3 $%Lbl:F3?$ 06/04/2025 **WARNING**READ AND FOLLOW ALL NOTES ON THIS DRAW ING! **IMPORTANT**FURNISH THIS DRAW ING TO ALL CONTRACTORS INCLUDING THE INSTALLERSTrusses require extreme care in fabricating, handling, shipping, installing and bracing. Refer to and follow the latest edition of BCSI (BuildingComponent Safety Information, by TPI and SBCA) for safety practices prior to performing these functions. Installers shall provide temporarybracing per BCSI. Unless noted otherwise, top chord shall have properly attached structural sheathing and bottom chord shall have a properlyattached rigid ceiling. Locations shown for permanent lateral restraint of webs shall have continuous lateral restraint (CLR), installed withdiagonal bracing installed on the CLR per BCSI sections B3, B7, or B10, as applicable. Apply plates to each face of truss and position asshown above and on the Joint Details, unless noted otherwise. Refer to drawings 160A-Z for standard plate positions. Refer to job's GeneralNotes page for additional information.Alpine, a division of ITW Building Components Group Inc. shall not be responsible for any deviation from this drawing, any failure to build thetruss in conformance with ANSI/TPI 1, or for handling, shipping, installation and bracing of trusses. A seal on this drawing or cover pagelisting this drawing, indicates acceptance of professional engineering responsibility solely for the design shown. The suitability and use of thisdrawing for any structure is the responsibility of the Building Designer per ANSI/TPI 1 Sec.2. For more information see these web sites: Alpine: alpineitw.com; TPI: tpinst.org; SBCA: sbcacomponents.com; ICC: iccsafe.org; AWC: awc.org 155 Harlem Ave North Building, 4th Floor Glenview, IL 60025 Lumber Top chord: 4x2 SP #2; Bot chord: 4x2 SP #2; Webs: 4x2 SP #3; Loading Bottom chord checked for 10.00 psf non-concurrent live load. Additional Notes + 2x6 continuous strongback. See detail STRBRIBR1014 for bracing and bridging recommendations. This truss spaced @ 16.0" oc supports additional concentrated load at left end from 10.00' stud wall (11.00 PSF) supporting 10-0-0 roof spans with 1-0-0 overhang. Roof load: 40.00 psf LL and 20.00 psf DL. Truss must be installed as shown with top chord up. Maximum Reactions (lbs) Gravity Non-Gravity Loc R+/ R-/ Rh / Rw / U / RL W 1387 /-/-/-/-/- T 564 /-/-/-/-/- M 361 /-43 /-/-/-/- W Brg Wid = 3.5 Min Req =1.5 (Truss) T Brg Wid = 3.5 Min Req =1.5 (Truss) M Brg Wid = 3.5 Min Req =1.5 (Truss) Bearings W , T, & M are a rigid surface. Members not listed have forces less than 375# Maximum Top Chord Forces Per Ply (lbs) Chords Tens.Comp. A - B 629 0 B - C 2032 0 C - D 1671 0 D - E 1662 0 E - F 1654 0 Chords Tens.Comp. F - G 1021 -14 G - H 644 -277 H - I 402 -497 I - J 216 -497 Maximum Bot Chord Forces Per Ply (lbs) Chords Tens.Comp. X - W 0 -1210 W -V 0 -2001 V - U 0 -1662 U - T 0 -1336 T - S 0 -1336 Chords Tens.Comp. S - R 133 -834 R - Q 494 -409 Q - P 497 -402 P - O 501 -395 O - N 451 -106 Maximum Web Forces Per Ply (lbs) Webs Tens.Comp. A - X 0 -945 X - B 923 0 B - W 0 -1216 W -C 0 -526 C - V 664 0 U - F 26 -563 Webs Tens.Comp. F - T 69 -510 F - S 663 0 S - G 0 -633 G - R 454 0 R - H 0 -543 Loading Criteria (psf) TCLL:40.00 TCDL:10.00 BCLL:0.00 BCDL:5.00 Des Ld:55.00 NCBCLL:10.00 Soffit:2.00 Load Duration: 1.00 Spacing: 16.0 " Wind Criteria Wind Std:NA Speed:NA mph Enclosure: NA Category: NA EXP: NA Kzt: NA Mean Height: NA ft TCDL: NA psf BCDL: NA psf MWFRS Parallel Dist: NA C&C Dist a: NA Loc. from endwall: NA I: NA GCpi: NA Wind Duration: NA Snow Criteria (Pg,Pf in PSF) Pg: NA Ct: NA CAT: NA Pf: NA Ce: NA Lu: NA Cs: NA Snow Duration: NA Building Code: IRC 2021 TPI Std:2014 Rep Fac: Yes FT/RT:12(0)/10(0) Plate Type(s): WAVE Defl/CSI Criteria PP Deflection in loc L/defl L/# VERT(LL):0.137 Y 352 360 VERT(CL):0.224 Y 216 240 HORZ(LL):-0.038 A - - HORZ(TL):0.062 A - - Creep Factor: 2.0 Max TC CSI:0.944 Max BC CSI:0.631 Max Web CSI:0.439 VIEW Ver: 24.01.01A.0510.10 Job Number:TS2207 84 LUMBER Truss Label:F4 Ply: 1 Qty:4 SEQN:120293 SY42 FROM: SC Cust: R 9462 JRef:1YaK94620001 T87 DrwNo:155.25.1735.08897 /BM 06/04/2025 3"8 3"8 3"12 4'1"4'12' 2'7"8 1'6"8 1'4"8 1'3"12 3" 2'6" (TYP) 3" 20'1" 4'2"12 4'2"12 5'8"12 1'6"6'7" 10"4 8'1" 1'6"13'4" 5'3" 14'8"8 1'4"8 20'1" 5'4"8 1'8" + A B C D E F G H I J K MNOPQRSTUVWXY 1X3 1X3 3X3 1X3 4X4 4X4 3X6 3X6 3X4 1X3 1X3 3X3 4X6 2X4 3X4 3X3 3X3 3X3 1X3 1X3 3X3 3X3 3X3 3X3 3X3 2X4 1X3 **WARNING**READ AND FOLLOW ALL NOTES ON THIS DRAW ING! **IMPORTANT**FURNISH THIS DRAW ING TO ALL CONTRACTORS INCLUDING THE INSTALLERSTrusses require extreme care in fabricating, handling, shipping, installing and bracing. Refer to and follow the latest edition of BCSI (BuildingComponent Safety Information, by TPI and SBCA) for safety practices prior to performing these functions. Installers shall provide temporarybracing per BCSI. Unless noted otherwise, top chord shall have properly attached structural sheathing and bottom chord shall have a properlyattached rigid ceiling. Locations shown for permanent lateral restraint of webs shall have continuous lateral restraint (CLR), installed withdiagonal bracing installed on the CLR per BCSI sections B3, B7, or B10, as applicable. Apply plates to each face of truss and position asshown above and on the Joint Details, unless noted otherwise. Refer to drawings 160A-Z for standard plate positions. Refer to job's GeneralNotes page for additional information.Alpine, a division of ITW Building Components Group Inc. shall not be responsible for any deviation from this drawing, any failure to build thetruss in conformance with ANSI/TPI 1, or for handling, shipping, installation and bracing of trusses. A seal on this drawing or cover pagelisting this drawing, indicates acceptance of professional engineering responsibility solely for the design shown. The suitability and use of thisdrawing for any structure is the responsibility of the Building Designer per ANSI/TPI 1 Sec.2. For more information see these web sites: Alpine: alpineitw.com; TPI: tpinst.org; SBCA: sbcacomponents.com; ICC: iccsafe.org; AWC: awc.org 155 Harlem Ave North Building, 4th Floor Glenview, IL 60025 Lumber Top chord: 4x2 SP #2; Bot chord: 4x2 SP #2; Webs: 4x2 SP #3; Loading Bottom chord checked for 10.00 psf non-concurrent live load. Additional Notes + 2x6 continuous strongback. See detail STRBRIBR1014 for bracing and bridging recommendations. This truss spaced @ 16.0" oc supports additional concentrated load at left end from 10.00' stud wall (11.00 PSF) supporting 10-0-0 roof spans with 1-0-0 overhang. Roof load: 40.00 psf LL and 20.00 psf DL. Truss must be installed as shown with top chord up. Maximum Reactions (lbs) Gravity Non-Gravity Loc R+/ R-/ Rh / Rw / U / RL W 1387 /-/-/-/-/- T 564 /-/-/-/-/- M 361 /-43 /-/-/-/- W Brg Wid = 3.5 Min Req =1.5 (Truss) T Brg Wid = 3.5 Min Req =1.5 (Truss) M Brg Wid = 3.5 Min Req =1.5 (Truss) Bearings W , T, & M are a rigid surface. Members not listed have forces less than 375# Maximum Top Chord Forces Per Ply (lbs) Chords Tens.Comp. A - B 629 0 B - C 2032 0 C - D 1671 0 D - E 1662 0 E - F 1654 0 Chords Tens.Comp. F - G 1021 -14 G - H 644 -277 H - I 402 -497 I - J 216 -497 Maximum Bot Chord Forces Per Ply (lbs) Chords Tens.Comp. X - W 0 -1210 W -V 0 -2001 V - U 0 -1662 U - T 0 -1336 T - S 0 -1336 Chords Tens.Comp. S - R 133 -834 R - Q 494 -409 Q - P 497 -402 P - O 501 -395 O - N 451 -106 Maximum Web Forces Per Ply (lbs) Webs Tens.Comp. A - X 0 -945 X - B 923 0 B - W 0 -1216 W -C 0 -526 C - V 664 0 U - F 26 -563 Webs Tens.Comp. F - T 69 -510 F - S 663 0 S - G 0 -633 G - R 454 0 R - H 0 -543 Loading Criteria (psf) TCLL:40.00 TCDL:10.00 BCLL:0.00 BCDL:5.00 Des Ld:55.00 NCBCLL:10.00 Soffit:2.00 Load Duration: 1.00 Spacing: 16.0 " Wind Criteria Wind Std:NA Speed:NA mph Enclosure: NA Category: NA EXP: NA Kzt: NA Mean Height: NA ft TCDL: NA psf BCDL: NA psf MWFRS Parallel Dist: NA C&C Dist a: NA Loc. from endwall: NA I: NA GCpi: NA Wind Duration: NA Snow Criteria (Pg,Pf in PSF) Pg: NA Ct: NA CAT: NA Pf: NA Ce: NA Lu: NA Cs: NA Snow Duration: NA Building Code: IRC 2021 TPI Std:2014 Rep Fac: Yes FT/RT:12(0)/10(0) Plate Type(s): WAVE Defl/CSI Criteria PP Deflection in loc L/defl L/# VERT(LL):0.137 Y 352 360 VERT(CL):0.224 Y 216 240 HORZ(LL):-0.038 A - - HORZ(TL):0.062 A - - Creep Factor: 2.0 Max TC CSI:0.944 Max BC CSI:0.631 Max Web CSI:0.439 VIEW Ver: 24.01.01A.0510.10 Job Number:TS2207 84 LUMBER Truss Label:F4 Ply: 1 Qty:4 SEQN:120293 SY42 FROM: SC Cust: R 9462 JRef:1YaK94620001 T87 DrwNo:155.25.1735.08897 /BM 06/04/2025 3"8 3"8 3"12 4'1"4'12' 2'7"8 1'6"8 1'4"8 1'3"12 3" 2'6" (TYP) 3" 20'1" 4'2"12 4'2"12 5'8"12 1'6"6'7" 10"4 8'1" 1'6"13'4" 5'3" 14'8"8 1'4"8 20'1" 5'4"8 1'8" + A B C D E F G H I J K MNOPQRSTUVWXY 1X3 1X3 3X3 1X3 4X4 4X4 3X6 3X6 3X4 1X3 1X3 3X3 4X6 2X4 3X4 3X3 3X3 3X3 1X3 1X3 3X3 3X3 3X3 3X3 3X3 2X4 1X3 $%Lbl:F4?$ 06/04/2025 **WARNING**READ AND FOLLOW ALL NOTES ON THIS DRAW ING! **IMPORTANT**FURNISH THIS DRAW ING TO ALL CONTRACTORS INCLUDING THE INSTALLERSTrusses require extreme care in fabricating, handling, shipping, installing and bracing. Refer to and follow the latest edition of BCSI (BuildingComponent Safety Information, by TPI and SBCA) for safety practices prior to performing these functions. Installers shall provide temporarybracing per BCSI. Unless noted otherwise, top chord shall have properly attached structural sheathing and bottom chord shall have a properlyattached rigid ceiling. Locations shown for permanent lateral restraint of webs shall have continuous lateral restraint (CLR), installed withdiagonal bracing installed on the CLR per BCSI sections B3, B7, or B10, as applicable. Apply plates to each face of truss and position asshown above and on the Joint Details, unless noted otherwise. Refer to drawings 160A-Z for standard plate positions. Refer to job's GeneralNotes page for additional information.Alpine, a division of ITW Building Components Group Inc. shall not be responsible for any deviation from this drawing, any failure to build thetruss in conformance with ANSI/TPI 1, or for handling, shipping, installation and bracing of trusses. A seal on this drawing or cover pagelisting this drawing, indicates acceptance of professional engineering responsibility solely for the design shown. The suitability and use of thisdrawing for any structure is the responsibility of the Building Designer per ANSI/TPI 1 Sec.2. For more information see these web sites: Alpine: alpineitw.com; TPI: tpinst.org; SBCA: sbcacomponents.com; ICC: iccsafe.org; AWC: awc.org 155 Harlem Ave North Building, 4th Floor Glenview, IL 60025 Lumber Top chord: 4x2 SP #2; Bot chord: 4x2 SP #1; B2 4x2 SP #2; Webs: 4x2 SP #3; Special Loads ------(Lumber Dur.Fac.=1.00 / Plate Dur.Fac.=1.00) TC: From 67 plf at 0.00 to 67 plf at 21.08 BC: From 7 plf at 0.00 to 7 plf at 21.21 TC: 600 lb Conc. Load at 5.48 TC: 325 lb Conc. Load at 9.33 Loading Bottom chord checked for 10.00 psf non-concurrent live load. Additional Notes + 2x6 continuous strongback. See detail STRBRIBR1014 for bracing and bridging recommendations. Maximum panel length exceeds 30". TPI allows non-bearing partition walls to be supported at any point when panels are 30" or less. Truss must be installed as shown with top chord up. Maximum Reactions (lbs) Gravity Non-Gravity Loc R+/ R-/ Rh / Rw / U / RL Y 1412 /-/-/-/-/- M 1060 /-/-/-/-/- Y Brg Wid = 3.5 Min Req =1.5 (Truss) M Brg Wid = 3.5 Min Req =1.5 (Truss) Bearings Y & M are a rigid surface. Members not listed have forces less than 375# Maximum Top Chord Forces Per Ply (lbs) Chords Tens.Comp. A - B 0 -1065 B - C 0 -3038 C - D 0 -4070 D - E 0 -4574 E - F 0 -4574 Chords Tens.Comp. F - G 0 -4728 G - H 0 -4194 H - I 0 -3351 I - J 0 -2251 J - K 0 -831 Maximum Bot Chord Forces Per Ply (lbs) Chords Tens.Comp. X - W 2131 0 W -V 4038 0 V - U 4383 0 U - T 4747 0 T - S 4506 0 Chords Tens.Comp. S - R 3848 0 R - Q 3848 0 Q - P 2866 0 P - O 2866 0 O - N 1618 0 Maximum Web Forces Per Ply (lbs) Webs Tens.Comp. A - Y 0 -1399 A - X 1693 0 X - B 0 -1694 B - W 1440 0 W -C 0 -1478 C - V 390 0 V - D 0 -502 G - S 0 -496 S - H 533 0 Webs Tens.Comp. H - Q 0 -766 Q - I 770 0 I - O 0 -978 O - J 1004 0 J - N 0 -1249 N - K 1283 0 K - L 0 -1046 L - M 0 -1050 Loading Criteria (psf) TCLL:40.00 TCDL:10.00 BCLL:0.00 BCDL:5.00 Des Ld:55.00 NCBCLL:10.00 Soffit:2.00 Load Duration: 1.00 Spacing: 16.0 " Wind Criteria Wind Std:NA Speed:NA mph Enclosure: NA Category: NA EXP: NA Kzt: NA Mean Height: NA ft TCDL: NA psf BCDL: NA psf MWFRS Parallel Dist: NA C&C Dist a: NA Loc. from endwall: NA I: NA GCpi: NA Wind Duration: NA Snow Criteria (Pg,Pf in PSF) Pg: NA Ct: NA CAT: NA Pf: NA Ce: NA Lu: NA Cs: NA Snow Duration: NA Building Code: IRC 2021 TPI Std:2014 Rep Fac: Varies by Ld Case FT/RT:12(0)/10(0) Plate Type(s): WAVE, HS Defl/CSI Criteria PP Deflection in loc L/defl L/# VERT(LL):0.461 F 540 360 VERT(CL):0.556 F 448 240 HORZ(LL):0.079 B - - HORZ(TL):0.096 B - - Creep Factor: 2.0 Max TC CSI:0.861 Max BC CSI:0.960 Max Web CSI:0.806 VIEW Ver: 24.01.01A.0510.10 Job Number:TS2207 84 LUMBER Truss Label:F5 Ply: 1 Qty:7 SEQN:120295 SY42 FROM: SC Cust: R 9462 JRef:1YaK94620001 T88 DrwNo:155.25.1735.10843 /BM 06/04/2025 B2 3"12 21'2"8 3" 2'6" (TYP) 2'8"1'4"4 1'6"12 2'6"12 2'6"12 3" 1'8" ++ A B C D E F G H I J KL MNOPQRSTUVWXY 5X6 2X4 5X6 5X6 5X6 4X4 3X3 3X3W=3X4 3X3 3X3 3X3 3X3 3X3 4X4 1X3 4X4 W=H0310 4X4 4X4 4X4 4X6 4X4 2X4 1X3 **WARNING**READ AND FOLLOW ALL NOTES ON THIS DRAW ING! **IMPORTANT**FURNISH THIS DRAW ING TO ALL CONTRACTORS INCLUDING THE INSTALLERSTrusses require extreme care in fabricating, handling, shipping, installing and bracing. Refer to and follow the latest edition of BCSI (BuildingComponent Safety Information, by TPI and SBCA) for safety practices prior to performing these functions. Installers shall provide temporarybracing per BCSI. Unless noted otherwise, top chord shall have properly attached structural sheathing and bottom chord shall have a properlyattached rigid ceiling. Locations shown for permanent lateral restraint of webs shall have continuous lateral restraint (CLR), installed withdiagonal bracing installed on the CLR per BCSI sections B3, B7, or B10, as applicable. Apply plates to each face of truss and position asshown above and on the Joint Details, unless noted otherwise. Refer to drawings 160A-Z for standard plate positions. Refer to job's GeneralNotes page for additional information.Alpine, a division of ITW Building Components Group Inc. shall not be responsible for any deviation from this drawing, any failure to build thetruss in conformance with ANSI/TPI 1, or for handling, shipping, installation and bracing of trusses. A seal on this drawing or cover pagelisting this drawing, indicates acceptance of professional engineering responsibility solely for the design shown. The suitability and use of thisdrawing for any structure is the responsibility of the Building Designer per ANSI/TPI 1 Sec.2. For more information see these web sites: Alpine: alpineitw.com; TPI: tpinst.org; SBCA: sbcacomponents.com; ICC: iccsafe.org; AWC: awc.org 155 Harlem Ave North Building, 4th Floor Glenview, IL 60025 Lumber Top chord: 4x2 SP #2; Bot chord: 4x2 SP #1; B2 4x2 SP #2; Webs: 4x2 SP #3; Special Loads ------(Lumber Dur.Fac.=1.00 / Plate Dur.Fac.=1.00) TC: From 67 plf at 0.00 to 67 plf at 21.08 BC: From 7 plf at 0.00 to 7 plf at 21.21 TC: 600 lb Conc. Load at 5.48 TC: 325 lb Conc. Load at 9.33 Loading Bottom chord checked for 10.00 psf non-concurrent live load. Additional Notes + 2x6 continuous strongback. See detail STRBRIBR1014 for bracing and bridging recommendations. Maximum panel length exceeds 30". TPI allows non-bearing partition walls to be supported at any point when panels are 30" or less. Truss must be installed as shown with top chord up. Maximum Reactions (lbs) Gravity Non-Gravity Loc R+/ R-/ Rh / Rw / U / RL Y 1412 /-/-/-/-/- M 1060 /-/-/-/-/- Y Brg Wid = 3.5 Min Req =1.5 (Truss) M Brg Wid = 3.5 Min Req =1.5 (Truss) Bearings Y & M are a rigid surface. Members not listed have forces less than 375# Maximum Top Chord Forces Per Ply (lbs) Chords Tens.Comp. A - B 0 -1065 B - C 0 -3038 C - D 0 -4070 D - E 0 -4574 E - F 0 -4574 Chords Tens.Comp. F - G 0 -4728 G - H 0 -4194 H - I 0 -3351 I - J 0 -2251 J - K 0 -831 Maximum Bot Chord Forces Per Ply (lbs) Chords Tens.Comp. X - W 2131 0 W -V 4038 0 V - U 4383 0 U - T 4747 0 T - S 4506 0 Chords Tens.Comp. S - R 3848 0 R - Q 3848 0 Q - P 2866 0 P - O 2866 0 O - N 1618 0 Maximum Web Forces Per Ply (lbs) Webs Tens.Comp. A - Y 0 -1399 A - X 1693 0 X - B 0 -1694 B - W 1440 0 W -C 0 -1478 C - V 390 0 V - D 0 -502 G - S 0 -496 S - H 533 0 Webs Tens.Comp. H - Q 0 -766 Q - I 770 0 I - O 0 -978 O - J 1004 0 J - N 0 -1249 N - K 1283 0 K - L 0 -1046 L - M 0 -1050 Loading Criteria (psf) TCLL:40.00 TCDL:10.00 BCLL:0.00 BCDL:5.00 Des Ld:55.00 NCBCLL:10.00 Soffit:2.00 Load Duration: 1.00 Spacing: 16.0 " Wind Criteria Wind Std:NA Speed:NA mph Enclosure: NA Category: NA EXP: NA Kzt: NA Mean Height: NA ft TCDL: NA psf BCDL: NA psf MWFRS Parallel Dist: NA C&C Dist a: NA Loc. from endwall: NA I: NA GCpi: NA Wind Duration: NA Snow Criteria (Pg,Pf in PSF) Pg: NA Ct: NA CAT: NA Pf: NA Ce: NA Lu: NA Cs: NA Snow Duration: NA Building Code: IRC 2021 TPI Std:2014 Rep Fac: Varies by Ld Case FT/RT:12(0)/10(0) Plate Type(s): WAVE, HS Defl/CSI Criteria PP Deflection in loc L/defl L/# VERT(LL):0.461 F 540 360 VERT(CL):0.556 F 448 240 HORZ(LL):0.079 B - - HORZ(TL):0.096 B - - Creep Factor: 2.0 Max TC CSI:0.861 Max BC CSI:0.960 Max Web CSI:0.806 VIEW Ver: 24.01.01A.0510.10 Job Number:TS2207 84 LUMBER Truss Label:F5 Ply: 1 Qty:7 SEQN:120295 SY42 FROM: SC Cust: R 9462 JRef:1YaK94620001 T88 DrwNo:155.25.1735.10843 /BM 06/04/2025 B2 3"12 21'2"8 3" 2'6" (TYP) 2'8"1'4"4 1'6"12 2'6"12 2'6"12 3" 1'8" ++ A B C D E F G H I J KL MNOPQRSTUVWXY 5X6 2X4 5X6 5X6 5X6 4X4 3X3 3X3W=3X4 3X3 3X3 3X3 3X3 3X3 4X4 1X3 4X4 W=H0310 4X4 4X4 4X4 4X6 4X4 2X4 1X3 $%Lbl:F5?$ 06/04/2025 **WARNING**READ AND FOLLOW ALL NOTES ON THIS DRAW ING! **IMPORTANT**FURNISH THIS DRAW ING TO ALL CONTRACTORS INCLUDING THE INSTALLERSTrusses require extreme care in fabricating, handling, shipping, installing and bracing. Refer to and follow the latest edition of BCSI (BuildingComponent Safety Information, by TPI and SBCA) for safety practices prior to performing these functions. Installers shall provide temporarybracing per BCSI. Unless noted otherwise, top chord shall have properly attached structural sheathing and bottom chord shall have a properlyattached rigid ceiling. Locations shown for permanent lateral restraint of webs shall have continuous lateral restraint (CLR), installed withdiagonal bracing installed on the CLR per BCSI sections B3, B7, or B10, as applicable. Apply plates to each face of truss and position asshown above and on the Joint Details, unless noted otherwise. Refer to drawings 160A-Z for standard plate positions. Refer to job's GeneralNotes page for additional information.Alpine, a division of ITW Building Components Group Inc. shall not be responsible for any deviation from this drawing, any failure to build thetruss in conformance with ANSI/TPI 1, or for handling, shipping, installation and bracing of trusses. A seal on this drawing or cover pagelisting this drawing, indicates acceptance of professional engineering responsibility solely for the design shown. The suitability and use of thisdrawing for any structure is the responsibility of the Building Designer per ANSI/TPI 1 Sec.2. For more information see these web sites: Alpine: alpineitw.com; TPI: tpinst.org; SBCA: sbcacomponents.com; ICC: iccsafe.org; AWC: awc.org 155 Harlem Ave North Building, 4th Floor Glenview, IL 60025 Lumber Top chord: 4x2 SP #2; Bot chord: 4x2 SP #2; Webs: 4x2 SP #3; Loading Bottom chord checked for 10.00 psf non-concurrent live load. Additional Notes + 2x6 continuous strongback. See detail STRBRIBR1014 for bracing and bridging recommendations. Truss must be installed as shown with top chord up. Maximum Reactions (lbs) Gravity Non-Gravity Loc R+/ R-/ Rh / Rw / U / RL R 857 /-/-/-/-/- J 838 /-/-/-/-/- R Brg Wid = 3.5 Min Req =1.5 (Truss) J Brg Wid = 3.5 Min Req =1.5 (Truss) Bearings R & J are a rigid surface. Members not listed have forces less than 375# Maximum Top Chord Forces Per Ply (lbs) Chords Tens.Comp. A - B 0 -581 B - C 0 -1501 C - D 0 -1941 D - E 0 -2010 Chords Tens.Comp. E - F 0 -2004 F - G 0 -1510 G - H 0 -613 Maximum Bot Chord Forces Per Ply (lbs) Chords Tens.Comp. Q - P 1153 0 P - O 1828 0 O - N 2013 0 Chords Tens.Comp. N - M 2010 0 M - L 1827 0 L - K 1181 0 Maximum Web Forces Per Ply (lbs) Webs Tens.Comp. A - R 0 -849 A - Q 927 0 Q - B 0 -908 B - P 552 0 P - C 0 -519 M - F 434 -9 Webs Tens.Comp. F - L 0 -504 L - G 522 0 G - K 0 -903 K - H 946 0 H - I 0 -822 I - J 0 -827 Loading Criteria (psf) TCLL:40.00 TCDL:10.00 BCLL:0.00 BCDL:5.00 Des Ld:55.00 NCBCLL:10.00 Soffit:2.00 Load Duration: 1.00 Spacing: 24.0 " Wind Criteria Wind Std:NA Speed:NA mph Enclosure: NA Category: NA EXP: NA Kzt: NA Mean Height: NA ft TCDL: NA psf BCDL: NA psf MWFRS Parallel Dist: NA C&C Dist a: NA Loc. from endwall: NA I: NA GCpi: NA Wind Duration: NA Snow Criteria (Pg,Pf in PSF) Pg: NA Ct: NA CAT: NA Pf: NA Ce: NA Lu: NA Cs: NA Snow Duration: NA Building Code: IRC 2021 TPI Std:2014 Rep Fac: Yes FT/RT:12(0)/10(0) Plate Type(s): WAVE Defl/CSI Criteria PP Deflection in loc L/defl L/# VERT(LL):0.136 D 999 360 VERT(CL):0.187 D 966 240 HORZ(LL):0.025 B - - HORZ(TL):0.034 B - - Creep Factor: 2.0 Max TC CSI:0.485 Max BC CSI:0.754 Max Web CSI:0.450 VIEW Ver: 24.01.01A.0510.10 Job Number:TS2207 84 LUMBER Truss Label:F6 Ply: 1 Qty:2 SEQN:120297 SY42 FROM: SC Cust: R 9462 JRef:1YaK94620001 T89 DrwNo:155.25.1735.12420 /BM 06/04/2025 3"12 15'6"4 3"2'6" (TYP) 1'3"12 3" 7'10"8 7'10"8 8'10"12 1'0"4 15'6"4 6'7"8 1'8"+ A B C D E F G H I JKLMNOPQR 4X6 2X4 4X4 3X3 3X3 3X3 3X3 3X3 1X3 1X3 3X3 3X3 3X3 3X3 4X4 4X4 2X4 1X3 **WARNING**READ AND FOLLOW ALL NOTES ON THIS DRAW ING! **IMPORTANT**FURNISH THIS DRAW ING TO ALL CONTRACTORS INCLUDING THE INSTALLERSTrusses require extreme care in fabricating, handling, shipping, installing and bracing. Refer to and follow the latest edition of BCSI (BuildingComponent Safety Information, by TPI and SBCA) for safety practices prior to performing these functions. Installers shall provide temporarybracing per BCSI. Unless noted otherwise, top chord shall have properly attached structural sheathing and bottom chord shall have a properlyattached rigid ceiling. Locations shown for permanent lateral restraint of webs shall have continuous lateral restraint (CLR), installed withdiagonal bracing installed on the CLR per BCSI sections B3, B7, or B10, as applicable. Apply plates to each face of truss and position asshown above and on the Joint Details, unless noted otherwise. Refer to drawings 160A-Z for standard plate positions. Refer to job's GeneralNotes page for additional information.Alpine, a division of ITW Building Components Group Inc. shall not be responsible for any deviation from this drawing, any failure to build thetruss in conformance with ANSI/TPI 1, or for handling, shipping, installation and bracing of trusses. A seal on this drawing or cover pagelisting this drawing, indicates acceptance of professional engineering responsibility solely for the design shown. The suitability and use of thisdrawing for any structure is the responsibility of the Building Designer per ANSI/TPI 1 Sec.2. For more information see these web sites: Alpine: alpineitw.com; TPI: tpinst.org; SBCA: sbcacomponents.com; ICC: iccsafe.org; AWC: awc.org 155 Harlem Ave North Building, 4th Floor Glenview, IL 60025 Lumber Top chord: 4x2 SP #2; Bot chord: 4x2 SP #2; Webs: 4x2 SP #3; Loading Bottom chord checked for 10.00 psf non-concurrent live load. Additional Notes + 2x6 continuous strongback. See detail STRBRIBR1014 for bracing and bridging recommendations. Truss must be installed as shown with top chord up. Maximum Reactions (lbs) Gravity Non-Gravity Loc R+/ R-/ Rh / Rw / U / RL R 857 /-/-/-/-/- J 838 /-/-/-/-/- R Brg Wid = 3.5 Min Req =1.5 (Truss) J Brg Wid = 3.5 Min Req =1.5 (Truss) Bearings R & J are a rigid surface. Members not listed have forces less than 375# Maximum Top Chord Forces Per Ply (lbs) Chords Tens.Comp. A - B 0 -581 B - C 0 -1501 C - D 0 -1941 D - E 0 -2010 Chords Tens.Comp. E - F 0 -2004 F - G 0 -1510 G - H 0 -613 Maximum Bot Chord Forces Per Ply (lbs) Chords Tens.Comp. Q - P 1153 0 P - O 1828 0 O - N 2013 0 Chords Tens.Comp. N - M 2010 0 M - L 1827 0 L - K 1181 0 Maximum Web Forces Per Ply (lbs) Webs Tens.Comp. A - R 0 -849 A - Q 927 0 Q - B 0 -908 B - P 552 0 P - C 0 -519 M - F 434 -9 Webs Tens.Comp. F - L 0 -504 L - G 522 0 G - K 0 -903 K - H 946 0 H - I 0 -822 I - J 0 -827 Loading Criteria (psf) TCLL:40.00 TCDL:10.00 BCLL:0.00 BCDL:5.00 Des Ld:55.00 NCBCLL:10.00 Soffit:2.00 Load Duration: 1.00 Spacing: 24.0 " Wind Criteria Wind Std:NA Speed:NA mph Enclosure: NA Category: NA EXP: NA Kzt: NA Mean Height: NA ft TCDL: NA psf BCDL: NA psf MWFRS Parallel Dist: NA C&C Dist a: NA Loc. from endwall: NA I: NA GCpi: NA Wind Duration: NA Snow Criteria (Pg,Pf in PSF) Pg: NA Ct: NA CAT: NA Pf: NA Ce: NA Lu: NA Cs: NA Snow Duration: NA Building Code: IRC 2021 TPI Std:2014 Rep Fac: Yes FT/RT:12(0)/10(0) Plate Type(s): WAVE Defl/CSI Criteria PP Deflection in loc L/defl L/# VERT(LL):0.136 D 999 360 VERT(CL):0.187 D 966 240 HORZ(LL):0.025 B - - HORZ(TL):0.034 B - - Creep Factor: 2.0 Max TC CSI:0.485 Max BC CSI:0.754 Max Web CSI:0.450 VIEW Ver: 24.01.01A.0510.10 Job Number:TS2207 84 LUMBER Truss Label:F6 Ply: 1 Qty:2 SEQN:120297 SY42 FROM: SC Cust: R 9462 JRef:1YaK94620001 T89 DrwNo:155.25.1735.12420 /BM 06/04/2025 3"12 15'6"4 3"2'6" (TYP) 1'3"12 3" 7'10"8 7'10"8 8'10"12 1'0"4 15'6"4 6'7"8 1'8"+ A B C D E F G H I JKLMNOPQR 4X6 2X4 4X4 3X3 3X3 3X3 3X3 3X3 1X3 1X3 3X3 3X3 3X3 3X3 4X4 4X4 2X4 1X3 $%Lbl:F6?$ 06/04/2025 **WARNING**READ AND FOLLOW ALL NOTES ON THIS DRAW ING! **IMPORTANT**FURNISH THIS DRAW ING TO ALL CONTRACTORS INCLUDING THE INSTALLERSTrusses require extreme care in fabricating, handling, shipping, installing and bracing. Refer to and follow the latest edition of BCSI (BuildingComponent Safety Information, by TPI and SBCA) for safety practices prior to performing these functions. Installers shall provide temporarybracing per BCSI. Unless noted otherwise, top chord shall have properly attached structural sheathing and bottom chord shall have a properlyattached rigid ceiling. Locations shown for permanent lateral restraint of webs shall have continuous lateral restraint (CLR), installed withdiagonal bracing installed on the CLR per BCSI sections B3, B7, or B10, as applicable. Apply plates to each face of truss and position asshown above and on the Joint Details, unless noted otherwise. Refer to drawings 160A-Z for standard plate positions. Refer to job's GeneralNotes page for additional information.Alpine, a division of ITW Building Components Group Inc. shall not be responsible for any deviation from this drawing, any failure to build thetruss in conformance with ANSI/TPI 1, or for handling, shipping, installation and bracing of trusses. A seal on this drawing or cover pagelisting this drawing, indicates acceptance of professional engineering responsibility solely for the design shown. The suitability and use of thisdrawing for any structure is the responsibility of the Building Designer per ANSI/TPI 1 Sec.2. For more information see these web sites: Alpine: alpineitw.com; TPI: tpinst.org; SBCA: sbcacomponents.com; ICC: iccsafe.org; AWC: awc.org 155 Harlem Ave North Building, 4th Floor Glenview, IL 60025 Lumber Top chord: 4x2 SP #2; Bot chord: 4x2 SP #2; Webs: 4x2 SP #3; Loading Bottom chord checked for 10.00 psf non-concurrent live load. Additional Notes + 2x6 continuous strongback. See detail STRBRIBR1014 for bracing and bridging recommendations. Truss must be installed as shown with top chord up. Maximum Reactions (lbs) Gravity Non-Gravity Loc R+/ R-/ Rh / Rw / U / RL S 857 /-/-/-/-/- J 847 /-/-/-/-/- S Brg Wid = 3.5 Min Req =1.5 (Truss) J Brg Wid = 3.8 Min Req =1.5 (Truss) Bearings S & I are a rigid surface. Members not listed have forces less than 375# Maximum Top Chord Forces Per Ply (lbs) Chords Tens.Comp. A - B 0 -581 B - C 0 -1501 C - D 0 -1941 D - E 0 -2017 Chords Tens.Comp. E - F 0 -2012 F - G 0 -1565 G - H 0 -649 H - I 0 -676 Maximum Bot Chord Forces Per Ply (lbs) Chords Tens.Comp. R - Q 1153 0 Q - P 1827 0 P - O 2019 0 Chords Tens.Comp. O - N 2017 0 N - M 1852 0 M - L 1265 0 Maximum Web Forces Per Ply (lbs) Webs Tens.Comp. A - S 0 -849 A - R 927 0 R - B 0 -908 B - Q 552 0 Q - C 0 -518 Webs Tens.Comp. N - F 405 -27 F - M 0 -456 M - G 475 0 G - L 0 -936 L - I 1009 0 Loading Criteria (psf) TCLL:40.00 TCDL:10.00 BCLL:0.00 BCDL:5.00 Des Ld:55.00 NCBCLL:10.00 Soffit:2.00 Load Duration: 1.00 Spacing: 24.0 " Wind Criteria Wind Std:NA Speed:NA mph Enclosure: NA Category: NA EXP: NA Kzt: NA Mean Height: NA ft TCDL: NA psf BCDL: NA psf MWFRS Parallel Dist: NA C&C Dist a: NA Loc. from endwall: NA I: NA GCpi: NA Wind Duration: NA Snow Criteria (Pg,Pf in PSF) Pg: NA Ct: NA CAT: NA Pf: NA Ce: NA Lu: NA Cs: NA Snow Duration: NA Building Code: IRC 2021 TPI Std:2014 Rep Fac: Yes FT/RT:12(0)/10(0) Plate Type(s): WAVE Defl/CSI Criteria PP Deflection in loc L/defl L/# VERT(LL):0.138 D 999 360 VERT(CL):0.189 D 958 240 HORZ(LL):0.025 B - - HORZ(TL):0.035 B - - Creep Factor: 2.0 Max TC CSI:0.799 Max BC CSI:0.698 Max Web CSI:0.481 VIEW Ver: 24.01.01A.0510.10 Job Number:TS2207 84 LUMBER Truss Label:F7 Ply: 1 Qty:5 SEQN:120299 SY42 FROM: SC Cust: R 9462 JRef:1YaK94620001 T90 DrwNo:155.25.1735.13950 /BM 06/04/2025 15'6"4 3"2'6" (TYP) 1'3"12 5"4 7'10"8 7'10"8 8'8"8 10" 15'6"4 6'9"12 1'8" 1'5" 3" + A B C D E F G H I J KLMNOPQRS 4X6 2X4 4X4 3X3 3X3 3X3 3X3 3X3 1X3 1X3 3X3 3X3 3X3 3X3 3X3 4X6 4X6 1X3 **WARNING**READ AND FOLLOW ALL NOTES ON THIS DRAW ING! **IMPORTANT**FURNISH THIS DRAW ING TO ALL CONTRACTORS INCLUDING THE INSTALLERSTrusses require extreme care in fabricating, handling, shipping, installing and bracing. Refer to and follow the latest edition of BCSI (BuildingComponent Safety Information, by TPI and SBCA) for safety practices prior to performing these functions. Installers shall provide temporarybracing per BCSI. Unless noted otherwise, top chord shall have properly attached structural sheathing and bottom chord shall have a properlyattached rigid ceiling. Locations shown for permanent lateral restraint of webs shall have continuous lateral restraint (CLR), installed withdiagonal bracing installed on the CLR per BCSI sections B3, B7, or B10, as applicable. Apply plates to each face of truss and position asshown above and on the Joint Details, unless noted otherwise. Refer to drawings 160A-Z for standard plate positions. Refer to job's GeneralNotes page for additional information.Alpine, a division of ITW Building Components Group Inc. shall not be responsible for any deviation from this drawing, any failure to build thetruss in conformance with ANSI/TPI 1, or for handling, shipping, installation and bracing of trusses. A seal on this drawing or cover pagelisting this drawing, indicates acceptance of professional engineering responsibility solely for the design shown. The suitability and use of thisdrawing for any structure is the responsibility of the Building Designer per ANSI/TPI 1 Sec.2. For more information see these web sites: Alpine: alpineitw.com; TPI: tpinst.org; SBCA: sbcacomponents.com; ICC: iccsafe.org; AWC: awc.org 155 Harlem Ave North Building, 4th Floor Glenview, IL 60025 Lumber Top chord: 4x2 SP #2; Bot chord: 4x2 SP #2; Webs: 4x2 SP #3; Loading Bottom chord checked for 10.00 psf non-concurrent live load. Additional Notes + 2x6 continuous strongback. See detail STRBRIBR1014 for bracing and bridging recommendations. Truss must be installed as shown with top chord up. Maximum Reactions (lbs) Gravity Non-Gravity Loc R+/ R-/ Rh / Rw / U / RL S 857 /-/-/-/-/- J 847 /-/-/-/-/- S Brg Wid = 3.5 Min Req =1.5 (Truss) J Brg Wid = 3.8 Min Req =1.5 (Truss) Bearings S & I are a rigid surface. Members not listed have forces less than 375# Maximum Top Chord Forces Per Ply (lbs) Chords Tens.Comp. A - B 0 -581 B - C 0 -1501 C - D 0 -1941 D - E 0 -2017 Chords Tens.Comp. E - F 0 -2012 F - G 0 -1565 G - H 0 -649 H - I 0 -676 Maximum Bot Chord Forces Per Ply (lbs) Chords Tens.Comp. R - Q 1153 0 Q - P 1827 0 P - O 2019 0 Chords Tens.Comp. O - N 2017 0 N - M 1852 0 M - L 1265 0 Maximum Web Forces Per Ply (lbs) Webs Tens.Comp. A - S 0 -849 A - R 927 0 R - B 0 -908 B - Q 552 0 Q - C 0 -518 Webs Tens.Comp. N - F 405 -27 F - M 0 -456 M - G 475 0 G - L 0 -936 L - I 1009 0 Loading Criteria (psf) TCLL:40.00 TCDL:10.00 BCLL:0.00 BCDL:5.00 Des Ld:55.00 NCBCLL:10.00 Soffit:2.00 Load Duration: 1.00 Spacing: 24.0 " Wind Criteria Wind Std:NA Speed:NA mph Enclosure: NA Category: NA EXP: NA Kzt: NA Mean Height: NA ft TCDL: NA psf BCDL: NA psf MWFRS Parallel Dist: NA C&C Dist a: NA Loc. from endwall: NA I: NA GCpi: NA Wind Duration: NA Snow Criteria (Pg,Pf in PSF) Pg: NA Ct: NA CAT: NA Pf: NA Ce: NA Lu: NA Cs: NA Snow Duration: NA Building Code: IRC 2021 TPI Std:2014 Rep Fac: Yes FT/RT:12(0)/10(0) Plate Type(s): WAVE Defl/CSI Criteria PP Deflection in loc L/defl L/# VERT(LL):0.138 D 999 360 VERT(CL):0.189 D 958 240 HORZ(LL):0.025 B - - HORZ(TL):0.035 B - - Creep Factor: 2.0 Max TC CSI:0.799 Max BC CSI:0.698 Max Web CSI:0.481 VIEW Ver: 24.01.01A.0510.10 Job Number:TS2207 84 LUMBER Truss Label:F7 Ply: 1 Qty:5 SEQN:120299 SY42 FROM: SC Cust: R 9462 JRef:1YaK94620001 T90 DrwNo:155.25.1735.13950 /BM 06/04/2025 15'6"4 3"2'6" (TYP) 1'3"12 5"4 7'10"8 7'10"8 8'8"8 10" 15'6"4 6'9"12 1'8" 1'5" 3" + A B C D E F G H I J KLMNOPQRS 4X6 2X4 4X4 3X3 3X3 3X3 3X3 3X3 1X3 1X3 3X3 3X3 3X3 3X3 3X3 4X6 4X6 1X3 $%Lbl:F7?$ 06/04/2025 **WARNING**READ AND FOLLOW ALL NOTES ON THIS DRAW ING! **IMPORTANT**FURNISH THIS DRAW ING TO ALL CONTRACTORS INCLUDING THE INSTALLERSTrusses require extreme care in fabricating, handling, shipping, installing and bracing. Refer to and follow the latest edition of BCSI (BuildingComponent Safety Information, by TPI and SBCA) for safety practices prior to performing these functions. Installers shall provide temporarybracing per BCSI. Unless noted otherwise, top chord shall have properly attached structural sheathing and bottom chord shall have a properlyattached rigid ceiling. Locations shown for permanent lateral restraint of webs shall have continuous lateral restraint (CLR), installed withdiagonal bracing installed on the CLR per BCSI sections B3, B7, or B10, as applicable. Apply plates to each face of truss and position asshown above and on the Joint Details, unless noted otherwise. Refer to drawings 160A-Z for standard plate positions. Refer to job's GeneralNotes page for additional information.Alpine, a division of ITW Building Components Group Inc. shall not be responsible for any deviation from this drawing, any failure to build thetruss in conformance with ANSI/TPI 1, or for handling, shipping, installation and bracing of trusses. A seal on this drawing or cover pagelisting this drawing, indicates acceptance of professional engineering responsibility solely for the design shown. The suitability and use of thisdrawing for any structure is the responsibility of the Building Designer per ANSI/TPI 1 Sec.2. For more information see these web sites: Alpine: alpineitw.com; TPI: tpinst.org; SBCA: sbcacomponents.com; ICC: iccsafe.org; AWC: awc.org 155 Harlem Ave North Building, 4th Floor Glenview, IL 60025 Lumber Top chord: 4x2 SP #2; Bot chord: 4x2 SP #2; Webs: 4x2 SP #3; Loading Bottom chord checked for 10.00 psf non-concurrent live load. Additional Notes + 2x6 continuous strongback. See detail STRBRIBR1014 for bracing and bridging recommendations. Truss must be installed as shown with top chord up. Maximum Reactions (lbs) Gravity Non-Gravity Loc R+/ R-/ Rh / Rw / U / RL O 701 /-/-/-/-/- H 701 /-/-/-/-/- O Brg Wid = 3.5 Min Req =1.5 (Truss) H Brg Wid = 3.5 Min Req =1.5 (Truss) Bearings O & H are a rigid surface. Members not listed have forces less than 375# Maximum Top Chord Forces Per Ply (lbs) Chords Tens.Comp. A - B 0 -457 B - C 0 -1119 C - D 0 -1320 Chords Tens.Comp. D - E 0 -1321 E - F 0 -1118 F - G 0 -457 Maximum Bot Chord Forces Per Ply (lbs) Chords Tens.Comp. N - M 905 0 M - L 1307 0 L - K 1321 0 Chords Tens.Comp. K - J 1320 0 J - I 903 0 Maximum Web Forces Per Ply (lbs) Webs Tens.Comp. A - O 0 -693 A - N 728 0 N - B 0 -712 Webs Tens.Comp. F - I 0 -708 I - G 729 0 G - H 0 -679 Loading Criteria (psf) TCLL:40.00 TCDL:10.00 BCLL:0.00 BCDL:5.00 Des Ld:55.00 NCBCLL:10.00 Soffit:2.00 Load Duration: 1.00 Spacing: 24.0 " Wind Criteria Wind Std:NA Speed:NA mph Enclosure: NA Category: NA EXP: NA Kzt: NA Mean Height: NA ft TCDL: NA psf BCDL: NA psf MWFRS Parallel Dist: NA C&C Dist a: NA Loc. from endwall: NA I: NA GCpi: NA Wind Duration: NA Snow Criteria (Pg,Pf in PSF) Pg: NA Ct: NA CAT: NA Pf: NA Ce: NA Lu: NA Cs: NA Snow Duration: NA Building Code: IRC 2021 TPI Std:2014 Rep Fac: Yes FT/RT:12(0)/10(0) Plate Type(s): WAVE Defl/CSI Criteria PP Deflection in loc L/defl L/# VERT(LL):0.069 D 999 360 VERT(CL):0.095 D 999 240 HORZ(LL):0.013 I - - HORZ(TL):0.018 I - - Creep Factor: 2.0 Max TC CSI:0.452 Max BC CSI:0.443 Max Web CSI:0.347 VIEW Ver: 24.01.01A.0510.10 Job Number:TS2207 84 LUMBER Truss Label:F8 Ply: 1 Qty:5 SEQN:120301 SY42 FROM: SC Cust: R 9462 JRef:1YaK94620001 T91 DrwNo:155.25.1735.15350 /BM 06/04/2025 12'9" 3"2'6" (TYP) 1'3"12 3" 6'7"8 6'7"8 7'4"8 9" 12'9" 5'4"8 1'8" + A B C D E F G HIJKLMNO 3X6 2X4 4X4 3X3 3X3 3X3 3X3 1X3 1X3 3X3 3X3 3X3 4X4 3X6 2X4 **WARNING**READ AND FOLLOW ALL NOTES ON THIS DRAW ING! **IMPORTANT**FURNISH THIS DRAW ING TO ALL CONTRACTORS INCLUDING THE INSTALLERSTrusses require extreme care in fabricating, handling, shipping, installing and bracing. Refer to and follow the latest edition of BCSI (BuildingComponent Safety Information, by TPI and SBCA) for safety practices prior to performing these functions. Installers shall provide temporarybracing per BCSI. Unless noted otherwise, top chord shall have properly attached structural sheathing and bottom chord shall have a properlyattached rigid ceiling. Locations shown for permanent lateral restraint of webs shall have continuous lateral restraint (CLR), installed withdiagonal bracing installed on the CLR per BCSI sections B3, B7, or B10, as applicable. Apply plates to each face of truss and position asshown above and on the Joint Details, unless noted otherwise. Refer to drawings 160A-Z for standard plate positions. Refer to job's GeneralNotes page for additional information.Alpine, a division of ITW Building Components Group Inc. shall not be responsible for any deviation from this drawing, any failure to build thetruss in conformance with ANSI/TPI 1, or for handling, shipping, installation and bracing of trusses. A seal on this drawing or cover pagelisting this drawing, indicates acceptance of professional engineering responsibility solely for the design shown. The suitability and use of thisdrawing for any structure is the responsibility of the Building Designer per ANSI/TPI 1 Sec.2. For more information see these web sites: Alpine: alpineitw.com; TPI: tpinst.org; SBCA: sbcacomponents.com; ICC: iccsafe.org; AWC: awc.org 155 Harlem Ave North Building, 4th Floor Glenview, IL 60025 Lumber Top chord: 4x2 SP #2; Bot chord: 4x2 SP #2; Webs: 4x2 SP #3; Loading Bottom chord checked for 10.00 psf non-concurrent live load. Additional Notes + 2x6 continuous strongback. See detail STRBRIBR1014 for bracing and bridging recommendations. Truss must be installed as shown with top chord up. Maximum Reactions (lbs) Gravity Non-Gravity Loc R+/ R-/ Rh / Rw / U / RL O 701 /-/-/-/-/- H 701 /-/-/-/-/- O Brg Wid = 3.5 Min Req =1.5 (Truss) H Brg Wid = 3.5 Min Req =1.5 (Truss) Bearings O & H are a rigid surface. Members not listed have forces less than 375# Maximum Top Chord Forces Per Ply (lbs) Chords Tens.Comp. A - B 0 -457 B - C 0 -1119 C - D 0 -1320 Chords Tens.Comp. D - E 0 -1321 E - F 0 -1118 F - G 0 -457 Maximum Bot Chord Forces Per Ply (lbs) Chords Tens.Comp. N - M 905 0 M - L 1307 0 L - K 1321 0 Chords Tens.Comp. K - J 1320 0 J - I 903 0 Maximum Web Forces Per Ply (lbs) Webs Tens.Comp. A - O 0 -693 A - N 728 0 N - B 0 -712 Webs Tens.Comp. F - I 0 -708 I - G 729 0 G - H 0 -679 Loading Criteria (psf) TCLL:40.00 TCDL:10.00 BCLL:0.00 BCDL:5.00 Des Ld:55.00 NCBCLL:10.00 Soffit:2.00 Load Duration: 1.00 Spacing: 24.0 " Wind Criteria Wind Std:NA Speed:NA mph Enclosure: NA Category: NA EXP: NA Kzt: NA Mean Height: NA ft TCDL: NA psf BCDL: NA psf MWFRS Parallel Dist: NA C&C Dist a: NA Loc. from endwall: NA I: NA GCpi: NA Wind Duration: NA Snow Criteria (Pg,Pf in PSF) Pg: NA Ct: NA CAT: NA Pf: NA Ce: NA Lu: NA Cs: NA Snow Duration: NA Building Code: IRC 2021 TPI Std:2014 Rep Fac: Yes FT/RT:12(0)/10(0) Plate Type(s): WAVE Defl/CSI Criteria PP Deflection in loc L/defl L/# VERT(LL):0.069 D 999 360 VERT(CL):0.095 D 999 240 HORZ(LL):0.013 I - - HORZ(TL):0.018 I - - Creep Factor: 2.0 Max TC CSI:0.452 Max BC CSI:0.443 Max Web CSI:0.347 VIEW Ver: 24.01.01A.0510.10 Job Number:TS2207 84 LUMBER Truss Label:F8 Ply: 1 Qty:5 SEQN:120301 SY42 FROM: SC Cust: R 9462 JRef:1YaK94620001 T91 DrwNo:155.25.1735.15350 /BM 06/04/2025 12'9" 3"2'6" (TYP) 1'3"12 3" 6'7"8 6'7"8 7'4"8 9" 12'9" 5'4"8 1'8" + A B C D E F G HIJKLMNO 3X6 2X4 4X4 3X3 3X3 3X3 3X3 1X3 1X3 3X3 3X3 3X3 4X4 3X6 2X4 $%Lbl:F8?$ 06/04/2025 **WARNING**READ AND FOLLOW ALL NOTES ON THIS DRAW ING! **IMPORTANT**FURNISH THIS DRAW ING TO ALL CONTRACTORS INCLUDING THE INSTALLERSTrusses require extreme care in fabricating, handling, shipping, installing and bracing. Refer to and follow the latest edition of BCSI (BuildingComponent Safety Information, by TPI and SBCA) for safety practices prior to performing these functions. Installers shall provide temporarybracing per BCSI. Unless noted otherwise, top chord shall have properly attached structural sheathing and bottom chord shall have a properlyattached rigid ceiling. Locations shown for permanent lateral restraint of webs shall have continuous lateral restraint (CLR), installed withdiagonal bracing installed on the CLR per BCSI sections B3, B7, or B10, as applicable. Apply plates to each face of truss and position asshown above and on the Joint Details, unless noted otherwise. Refer to drawings 160A-Z for standard plate positions. Refer to job's GeneralNotes page for additional information.Alpine, a division of ITW Building Components Group Inc. shall not be responsible for any deviation from this drawing, any failure to build thetruss in conformance with ANSI/TPI 1, or for handling, shipping, installation and bracing of trusses. A seal on this drawing or cover pagelisting this drawing, indicates acceptance of professional engineering responsibility solely for the design shown. The suitability and use of thisdrawing for any structure is the responsibility of the Building Designer per ANSI/TPI 1 Sec.2. For more information see these web sites: Alpine: alpineitw.com; TPI: tpinst.org; SBCA: sbcacomponents.com; ICC: iccsafe.org; AWC: awc.org 155 Harlem Ave North Building, 4th Floor Glenview, IL 60025 Lumber Top chord: 4x2 SP SS; Bot chord: 4x2 SP #2; Webs: 4x2 SP #3; Special Loads ------(Lumber Dur.Fac.=1.00 / Plate Dur.Fac.=1.00) TC: From 400 plf at 0.00 to 400 plf at 19.69 BC: From 10 plf at 0.25 to 10 plf at 19.69 Loading Bottom chord checked for 10.00 psf non-concurrent live load. Additional Notes See detail STRBRIBR1014 for bracing and bridging recommendations. Truss must be installed as shown with top chord up. Maximum Reactions (lbs) Gravity Non-Gravity Loc R+/ R-/ Rh / Rw / U / RL A 1773 /-/-/-/-/- S 4288 /-/-/-/-/- M 2028 /-/-/-/-/- A Brg Wid = 3.0 Min Req =1.5 (Truss) S Brg Wid = 3.0 Min Req =1.8 (Truss) M Brg Wid = 3.5 Min Req =1.5 (Truss) Bearings A, S, & M are a rigid surface. Members not listed have forces less than 375# Maximum Top Chord Forces Per Ply (lbs) Chords Tens.Comp. B - C 0 -1295 C - D 0 -2453 D - E 0 -2457 E - F 0 -2430 F - G 0 -500 Chords Tens.Comp. G - H 0 -751 H - I 0 -3018 I - J 0 -3046 J - K 0 -2934 K - L 0 -1336 Maximum Bot Chord Forces Per Ply (lbs) Chords Tens.Comp. W -V 2450 0 V - U 2457 0 U - T 1793 0 T - S 0 -861 S - R 0 -861 Chords Tens.Comp. R - Q 2198 0 Q - P 3046 0 P - O 3061 0 O - N 2672 0 Maximum Web Forces Per Ply (lbs) Webs Tens.Comp. B - W 1889 0 W -C 0 -1746 E - U 0 -636 U - F 1030 0 F - T 0 -1965 T - G 1894 0 G - S 0 -4040 G - R 2078 0 Webs Tens.Comp. R - H 0 -2204 H - Q 1294 0 Q - I 0 -660 O - K 412 0 K - N 0 -2018 N - L 2011 0 L - M 0 -2038 Loading Criteria (psf) TCLL:40.00 TCDL:10.00 BCLL:0.00 BCDL:5.00 Des Ld:55.00 NCBCLL:10.00 Soffit:2.00 Load Duration: 1.00 Spacing: 24.0 " Wind Criteria Wind Std:NA Speed:NA mph Enclosure: NA Category: NA EXP: NA Kzt: NA Mean Height: NA ft TCDL: NA psf BCDL: NA psf MWFRS Parallel Dist: NA C&C Dist a: NA Loc. from endwall: NA I: NA GCpi: NA Wind Duration: NA Snow Criteria (Pg,Pf in PSF) Pg: NA Ct: NA CAT: NA Pf: NA Ce: NA Lu: NA Cs: NA Snow Duration: NA Building Code: IRC 2021 TPI Std:2014 Rep Fac: Varies by Ld Case FT/RT:12(0)/10(0) Plate Type(s): WAVE Defl/CSI Criteria PP Deflection in loc L/defl L/# VERT(LL):0.119 J 999 360 VERT(CL):0.166 J 728 240 HORZ(LL):-0.015 L - - HORZ(TL):0.021 L - - Creep Factor: 2.0 Max TC CSI:0.884 Max BC CSI:0.888 Max Web CSI:0.616 VIEW Ver: 24.01.01A.0510.10 Job Number:TS2207 84 LUMBER Truss Label:F9 Ply: 1 Qty:1 SEQN:120305 SY42 FROM: SC Cust: R 9462 JRef:1YaK94620001 T92 DrwNo:155.25.1735.17210 /BM 06/04/2025 9'4"8 10'3"12 4"8 2'6" (TYP) 1'3"12 1'3"12 3"1'3"12 3" 19'8"4 4'3" 4'3" 5'4"8 1'1"8 8' 2'7"8 8'2"3 2"3 9'4"8 1'2"5 13'4"8 4' 14'3"12 11"4 18'2"4 3'10"8 18'4"7 2"3 19'8"4 1'3"13 1'5" 3" 1"8 1'8" AB C D E F G H I J K L MNOPQRSTUVWX3X6 5X6 6X6 5X6 3X4 3X6 3X6 4X6 5X6 6X6 6X12 5X6 6X6 6X6 5X6 3X6 3X6 3X4 3X4 5X6 6X6 6X6 3X6 **WARNING**READ AND FOLLOW ALL NOTES ON THIS DRAW ING! **IMPORTANT**FURNISH THIS DRAW ING TO ALL CONTRACTORS INCLUDING THE INSTALLERSTrusses require extreme care in fabricating, handling, shipping, installing and bracing. Refer to and follow the latest edition of BCSI (BuildingComponent Safety Information, by TPI and SBCA) for safety practices prior to performing these functions. Installers shall provide temporarybracing per BCSI. Unless noted otherwise, top chord shall have properly attached structural sheathing and bottom chord shall have a properlyattached rigid ceiling. Locations shown for permanent lateral restraint of webs shall have continuous lateral restraint (CLR), installed withdiagonal bracing installed on the CLR per BCSI sections B3, B7, or B10, as applicable. Apply plates to each face of truss and position asshown above and on the Joint Details, unless noted otherwise. Refer to drawings 160A-Z for standard plate positions. Refer to job's GeneralNotes page for additional information.Alpine, a division of ITW Building Components Group Inc. shall not be responsible for any deviation from this drawing, any failure to build thetruss in conformance with ANSI/TPI 1, or for handling, shipping, installation and bracing of trusses. A seal on this drawing or cover pagelisting this drawing, indicates acceptance of professional engineering responsibility solely for the design shown. The suitability and use of thisdrawing for any structure is the responsibility of the Building Designer per ANSI/TPI 1 Sec.2. For more information see these web sites: Alpine: alpineitw.com; TPI: tpinst.org; SBCA: sbcacomponents.com; ICC: iccsafe.org; AWC: awc.org 155 Harlem Ave North Building, 4th Floor Glenview, IL 60025 Lumber Top chord: 4x2 SP SS; Bot chord: 4x2 SP #2; Webs: 4x2 SP #3; Special Loads ------(Lumber Dur.Fac.=1.00 / Plate Dur.Fac.=1.00) TC: From 400 plf at 0.00 to 400 plf at 19.69 BC: From 10 plf at 0.25 to 10 plf at 19.69 Loading Bottom chord checked for 10.00 psf non-concurrent live load. Additional Notes See detail STRBRIBR1014 for bracing and bridging recommendations. Truss must be installed as shown with top chord up. Maximum Reactions (lbs) Gravity Non-Gravity Loc R+/ R-/ Rh / Rw / U / RL A 1773 /-/-/-/-/- S 4288 /-/-/-/-/- M 2028 /-/-/-/-/- A Brg Wid = 3.0 Min Req =1.5 (Truss) S Brg Wid = 3.0 Min Req =1.8 (Truss) M Brg Wid = 3.5 Min Req =1.5 (Truss) Bearings A, S, & M are a rigid surface. Members not listed have forces less than 375# Maximum Top Chord Forces Per Ply (lbs) Chords Tens.Comp. B - C 0 -1295 C - D 0 -2453 D - E 0 -2457 E - F 0 -2430 F - G 0 -500 Chords Tens.Comp. G - H 0 -751 H - I 0 -3018 I - J 0 -3046 J - K 0 -2934 K - L 0 -1336 Maximum Bot Chord Forces Per Ply (lbs) Chords Tens.Comp. W -V 2450 0 V - U 2457 0 U - T 1793 0 T - S 0 -861 S - R 0 -861 Chords Tens.Comp. R - Q 2198 0 Q - P 3046 0 P - O 3061 0 O - N 2672 0 Maximum Web Forces Per Ply (lbs) Webs Tens.Comp. B - W 1889 0 W -C 0 -1746 E - U 0 -636 U - F 1030 0 F - T 0 -1965 T - G 1894 0 G - S 0 -4040 G - R 2078 0 Webs Tens.Comp. R - H 0 -2204 H - Q 1294 0 Q - I 0 -660 O - K 412 0 K - N 0 -2018 N - L 2011 0 L - M 0 -2038 Loading Criteria (psf) TCLL:40.00 TCDL:10.00 BCLL:0.00 BCDL:5.00 Des Ld:55.00 NCBCLL:10.00 Soffit:2.00 Load Duration: 1.00 Spacing: 24.0 " Wind Criteria Wind Std:NA Speed:NA mph Enclosure: NA Category: NA EXP: NA Kzt: NA Mean Height: NA ft TCDL: NA psf BCDL: NA psf MWFRS Parallel Dist: NA C&C Dist a: NA Loc. from endwall: NA I: NA GCpi: NA Wind Duration: NA Snow Criteria (Pg,Pf in PSF) Pg: NA Ct: NA CAT: NA Pf: NA Ce: NA Lu: NA Cs: NA Snow Duration: NA Building Code: IRC 2021 TPI Std:2014 Rep Fac: Varies by Ld Case FT/RT:12(0)/10(0) Plate Type(s): WAVE Defl/CSI Criteria PP Deflection in loc L/defl L/# VERT(LL):0.119 J 999 360 VERT(CL):0.166 J 728 240 HORZ(LL):-0.015 L - - HORZ(TL):0.021 L - - Creep Factor: 2.0 Max TC CSI:0.884 Max BC CSI:0.888 Max Web CSI:0.616 VIEW Ver: 24.01.01A.0510.10 Job Number:TS2207 84 LUMBER Truss Label:F9 Ply: 1 Qty:1 SEQN:120305 SY42 FROM: SC Cust: R 9462 JRef:1YaK94620001 T92 DrwNo:155.25.1735.17210 /BM 06/04/2025 9'4"8 10'3"12 4"8 2'6" (TYP) 1'3"12 1'3"12 3"1'3"12 3" 19'8"4 4'3" 4'3" 5'4"8 1'1"8 8' 2'7"8 8'2"3 2"3 9'4"8 1'2"5 13'4"8 4' 14'3"12 11"4 18'2"4 3'10"8 18'4"7 2"3 19'8"4 1'3"13 1'5" 3" 1"8 1'8" AB C D E F G H I J K L MNOPQRSTUVWX3X6 5X6 6X6 5X6 3X4 3X6 3X6 4X6 5X6 6X6 6X12 5X6 6X6 6X6 5X6 3X6 3X6 3X4 3X4 5X6 6X6 6X6 3X6 $%Lbl:F9?$ 06/04/2025 **WARNING**READ AND FOLLOW ALL NOTES ON THIS DRAW ING! **IMPORTANT**FURNISH THIS DRAW ING TO ALL CONTRACTORS INCLUDING THE INSTALLERSTrusses require extreme care in fabricating, handling, shipping, installing and bracing. Refer to and follow the latest edition of BCSI (BuildingComponent Safety Information, by TPI and SBCA) for safety practices prior to performing these functions. Installers shall provide temporarybracing per BCSI. Unless noted otherwise, top chord shall have properly attached structural sheathing and bottom chord shall have a properlyattached rigid ceiling. Locations shown for permanent lateral restraint of webs shall have continuous lateral restraint (CLR), installed withdiagonal bracing installed on the CLR per BCSI sections B3, B7, or B10, as applicable. Apply plates to each face of truss and position asshown above and on the Joint Details, unless noted otherwise. Refer to drawings 160A-Z for standard plate positions. Refer to job's GeneralNotes page for additional information.Alpine, a division of ITW Building Components Group Inc. shall not be responsible for any deviation from this drawing, any failure to build thetruss in conformance with ANSI/TPI 1, or for handling, shipping, installation and bracing of trusses. A seal on this drawing or cover pagelisting this drawing, indicates acceptance of professional engineering responsibility solely for the design shown. The suitability and use of thisdrawing for any structure is the responsibility of the Building Designer per ANSI/TPI 1 Sec.2. For more information see these web sites: Alpine: alpineitw.com; TPI: tpinst.org; SBCA: sbcacomponents.com; ICC: iccsafe.org; AWC: awc.org 155 Harlem Ave North Building, 4th Floor Glenview, IL 60025 Lumber Top chord: 4x2 SP #2; Bot chord: 4x2 SP #1; Webs: 4x2 SP #3; Special Loads ------(Lumber Dur.Fac.=1.00 / Plate Dur.Fac.=1.00) TC: From 220 plf at 0.00 to 220 plf at 0.12 TC: From 320 plf at 0.12 to 320 plf at 16.48 TC: From 100 plf at 16.48 to 100 plf at 16.62 BC: From 10 plf at 0.00 to 10 plf at 16.62 Plating Notes All plates are 7X8 except as noted. Loading Bottom chord checked for 10.00 psf non-concurrent live load. Additional Notes + 2x6 continuous strongback. See detail STRBRIBR1014 for bracing and bridging recommendations. Truss must be installed as shown with top chord up. Maximum Reactions (lbs) Gravity Non-Gravity Loc R+/ R-/ Rh / Rw / U / RL S 2758 /-/-/-/-/- J 2683 /-/-/-/-/- S Brg Wid = 2.0 Min Req =1.5 (Truss) J Brg Wid = 3.5 Min Req =1.5 (Truss) Bearings S & J are a rigid surface. Members not listed have forces less than 375# Maximum Top Chord Forces Per Ply (lbs) Chords Tens.Comp. A - B 0 -2235 B - C 0 -5565 C - D 0 -7362 D - E 0 -7881 Chords Tens.Comp. E - F 0 -7379 F - G 0 -5611 G - H 0 -2291 Maximum Bot Chord Forces Per Ply (lbs) Chords Tens.Comp. R - Q 4302 0 Q - P 6815 0 P - O 7881 0 O - N 7881 0 Chords Tens.Comp. N - M 7882 0 M - L 6847 0 L - K 4356 0 Maximum Web Forces Per Ply (lbs) Webs Tens.Comp. T - S 0 -2804 A - T 0 -2746 A - R 3293 0 R - B 0 -3124 B - Q 1908 0 Q - C 0 -1891 C - P 898 0 P - D 0 -930 Webs Tens.Comp. E - M 0 -908 M - F 878 0 F - L 0 -1867 L - G 1896 0 G - K 0 -3122 K - H 3196 0 H - J 0 -2160 I - U 0 -447 Loading Criteria (psf) TCLL:40.00 TCDL:10.00 BCLL:0.00 BCDL:5.00 Des Ld:55.00 NCBCLL:10.00 Soffit:2.00 Load Duration: 1.00 Spacing: 24.0 " Wind Criteria Wind Std:NA Speed:NA mph Enclosure: NA Category: NA EXP: NA Kzt: NA Mean Height: NA ft TCDL: NA psf BCDL: NA psf MWFRS Parallel Dist: NA C&C Dist a: NA Loc. from endwall: NA I: NA GCpi: NA Wind Duration: NA Snow Criteria (Pg,Pf in PSF) Pg: NA Ct: NA CAT: NA Pf: NA Ce: NA Lu: NA Cs: NA Snow Duration: NA Building Code: IRC 2021 TPI Std:2014 Rep Fac: Varies by Ld Case FT/RT:12(0)/10(0) Plate Type(s): WAVE Defl/CSI Criteria PP Deflection in loc L/defl L/# VERT(LL):0.325 N 607 360 VERT(CL):0.447 N 441 240 HORZ(LL):0.044 J - - HORZ(TL):0.061 J - - Creep Factor: 2.0 Max TC CSI:0.963 Max BC CSI:0.927 Max Web CSI:0.908 VIEW Ver: 24.01.01A.0510.10 Job Number:TS2207 84 LUMBER Truss Label:F10 Ply: 1 Qty:1 SEQN:120468 SY42 FROM: SC Cust: R 9462 JRef:1YaK94620001 T105 DrwNo:155.25.1734.38020 /BM 06/04/2025 3"12 2" 3"8 16'9" 3"2'6" (TYP) 3" 7'10"8 7'10"8 8'10"8 1' 15'3" 6'4"8 15'5"3 2"3 16'9" 1'3"13 1'8" 1"8 + A B C D E F G H I JKLMNOPQRS T U 1X3 4X6 6X8 7X12 5X6 5X6 4X4 3X6 3X6 4X4 5X6 5X6 7X12 6X8 3X6 1X3 1X3 **WARNING**READ AND FOLLOW ALL NOTES ON THIS DRAW ING! **IMPORTANT**FURNISH THIS DRAW ING TO ALL CONTRACTORS INCLUDING THE INSTALLERSTrusses require extreme care in fabricating, handling, shipping, installing and bracing. Refer to and follow the latest edition of BCSI (BuildingComponent Safety Information, by TPI and SBCA) for safety practices prior to performing these functions. Installers shall provide temporarybracing per BCSI. Unless noted otherwise, top chord shall have properly attached structural sheathing and bottom chord shall have a properlyattached rigid ceiling. Locations shown for permanent lateral restraint of webs shall have continuous lateral restraint (CLR), installed withdiagonal bracing installed on the CLR per BCSI sections B3, B7, or B10, as applicable. Apply plates to each face of truss and position asshown above and on the Joint Details, unless noted otherwise. Refer to drawings 160A-Z for standard plate positions. Refer to job's GeneralNotes page for additional information.Alpine, a division of ITW Building Components Group Inc. shall not be responsible for any deviation from this drawing, any failure to build thetruss in conformance with ANSI/TPI 1, or for handling, shipping, installation and bracing of trusses. A seal on this drawing or cover pagelisting this drawing, indicates acceptance of professional engineering responsibility solely for the design shown. The suitability and use of thisdrawing for any structure is the responsibility of the Building Designer per ANSI/TPI 1 Sec.2. For more information see these web sites: Alpine: alpineitw.com; TPI: tpinst.org; SBCA: sbcacomponents.com; ICC: iccsafe.org; AWC: awc.org 155 Harlem Ave North Building, 4th Floor Glenview, IL 60025 Lumber Top chord: 4x2 SP #2; Bot chord: 4x2 SP #1; Webs: 4x2 SP #3; Special Loads ------(Lumber Dur.Fac.=1.00 / Plate Dur.Fac.=1.00) TC: From 220 plf at 0.00 to 220 plf at 0.12 TC: From 320 plf at 0.12 to 320 plf at 16.48 TC: From 100 plf at 16.48 to 100 plf at 16.62 BC: From 10 plf at 0.00 to 10 plf at 16.62 Plating Notes All plates are 7X8 except as noted. Loading Bottom chord checked for 10.00 psf non-concurrent live load. Additional Notes + 2x6 continuous strongback. See detail STRBRIBR1014 for bracing and bridging recommendations. Truss must be installed as shown with top chord up. Maximum Reactions (lbs) Gravity Non-Gravity Loc R+/ R-/ Rh / Rw / U / RL S 2758 /-/-/-/-/- J 2683 /-/-/-/-/- S Brg Wid = 2.0 Min Req =1.5 (Truss) J Brg Wid = 3.5 Min Req =1.5 (Truss) Bearings S & J are a rigid surface. Members not listed have forces less than 375# Maximum Top Chord Forces Per Ply (lbs) Chords Tens.Comp. A - B 0 -2235 B - C 0 -5565 C - D 0 -7362 D - E 0 -7881 Chords Tens.Comp. E - F 0 -7379 F - G 0 -5611 G - H 0 -2291 Maximum Bot Chord Forces Per Ply (lbs) Chords Tens.Comp. R - Q 4302 0 Q - P 6815 0 P - O 7881 0 O - N 7881 0 Chords Tens.Comp. N - M 7882 0 M - L 6847 0 L - K 4356 0 Maximum Web Forces Per Ply (lbs) Webs Tens.Comp. T - S 0 -2804 A - T 0 -2746 A - R 3293 0 R - B 0 -3124 B - Q 1908 0 Q - C 0 -1891 C - P 898 0 P - D 0 -930 Webs Tens.Comp. E - M 0 -908 M - F 878 0 F - L 0 -1867 L - G 1896 0 G - K 0 -3122 K - H 3196 0 H - J 0 -2160 I - U 0 -447 Loading Criteria (psf) TCLL:40.00 TCDL:10.00 BCLL:0.00 BCDL:5.00 Des Ld:55.00 NCBCLL:10.00 Soffit:2.00 Load Duration: 1.00 Spacing: 24.0 " Wind Criteria Wind Std:NA Speed:NA mph Enclosure: NA Category: NA EXP: NA Kzt: NA Mean Height: NA ft TCDL: NA psf BCDL: NA psf MWFRS Parallel Dist: NA C&C Dist a: NA Loc. from endwall: NA I: NA GCpi: NA Wind Duration: NA Snow Criteria (Pg,Pf in PSF) Pg: NA Ct: NA CAT: NA Pf: NA Ce: NA Lu: NA Cs: NA Snow Duration: NA Building Code: IRC 2021 TPI Std:2014 Rep Fac: Varies by Ld Case FT/RT:12(0)/10(0) Plate Type(s): WAVE Defl/CSI Criteria PP Deflection in loc L/defl L/# VERT(LL):0.325 N 607 360 VERT(CL):0.447 N 441 240 HORZ(LL):0.044 J - - HORZ(TL):0.061 J - - Creep Factor: 2.0 Max TC CSI:0.963 Max BC CSI:0.927 Max Web CSI:0.908 VIEW Ver: 24.01.01A.0510.10 Job Number:TS2207 84 LUMBER Truss Label:F10 Ply: 1 Qty:1 SEQN:120468 SY42 FROM: SC Cust: R 9462 JRef:1YaK94620001 T105 DrwNo:155.25.1734.38020 /BM 06/04/2025 3"12 2" 3"8 16'9" 3"2'6" (TYP) 3" 7'10"8 7'10"8 8'10"8 1' 15'3" 6'4"8 15'5"3 2"3 16'9" 1'3"13 1'8" 1"8 + A B C D E F G H I JKLMNOPQRS T U 1X3 4X6 6X8 7X12 5X6 5X6 4X4 3X6 3X6 4X4 5X6 5X6 7X12 6X8 3X6 1X3 1X3 $%Lbl:F10?$ 06/04/2025 **WARNING**READ AND FOLLOW ALL NOTES ON THIS DRAW ING! **IMPORTANT**FURNISH THIS DRAW ING TO ALL CONTRACTORS INCLUDING THE INSTALLERSTrusses require extreme care in fabricating, handling, shipping, installing and bracing. Refer to and follow the latest edition of BCSI (BuildingComponent Safety Information, by TPI and SBCA) for safety practices prior to performing these functions. Installers shall provide temporarybracing per BCSI. Unless noted otherwise, top chord shall have properly attached structural sheathing and bottom chord shall have a properlyattached rigid ceiling. Locations shown for permanent lateral restraint of webs shall have continuous lateral restraint (CLR), installed withdiagonal bracing installed on the CLR per BCSI sections B3, B7, or B10, as applicable. Apply plates to each face of truss and position asshown above and on the Joint Details, unless noted otherwise. Refer to drawings 160A-Z for standard plate positions. Refer to job's GeneralNotes page for additional information.Alpine, a division of ITW Building Components Group Inc. shall not be responsible for any deviation from this drawing, any failure to build thetruss in conformance with ANSI/TPI 1, or for handling, shipping, installation and bracing of trusses. A seal on this drawing or cover pagelisting this drawing, indicates acceptance of professional engineering responsibility solely for the design shown. The suitability and use of thisdrawing for any structure is the responsibility of the Building Designer per ANSI/TPI 1 Sec.2. For more information see these web sites: Alpine: alpineitw.com; TPI: tpinst.org; SBCA: sbcacomponents.com; ICC: iccsafe.org; AWC: awc.org 155 Harlem Ave North Building, 4th Floor Glenview, IL 60025 Lumber Top chord: 4x2 SP #2; Bot chord: 4x2 SP #2; Webs: 4x2 SP #3; Special Loads ------(Lumber Dur.Fac.=1.00 / Plate Dur.Fac.=1.00) TC: From 100 plf at 0.12 to 100 plf at 23.88 BC: From 10 plf at 0.00 to 10 plf at 23.88 TC: 650 lb Conc. Load at 12.58,18.00 Loading Bottom chord checked for 10.00 psf non-concurrent live load. Additional Notes + 2x6 continuous strongback. See detail STRBRIBR1014 for bracing and bridging recommendations. Truss must be installed as shown with top chord up. Maximum Reactions (lbs) Gravity Non-Gravity Loc R+/ R-/ Rh / Rw / U / RL AB 897 /-/-/-/-/- R 2911 /-/-/-/-/- N 315 /-162 /-/-/-/- AB Brg Wid = 2.0 Min Req =1.5 (Truss) R Brg Wid = 2.0 Min Req =1.5 (Truss) N Brg Wid = 3.5 Min Req =1.5 (Truss) Bearings AB, R, & N are a rigid surface. Members not listed have forces less than 375# Maximum Top Chord Forces Per Ply (lbs) Chords Tens.Comp. A - B 0 -674 B - C 0 -1676 C - D 0 -2207 D - E 0 -2207 E - F 0 -2294 F - G 0 -1916 Chords Tens.Comp. G - H 0 -1619 H - I 603 0 I - J 934 0 J - K 934 0 K - L 548 -179 Maximum Bot Chord Forces Per Ply (lbs) Chords Tens.Comp. AA- Z 1291 0 Z - Y 2040 0 Y - X 2362 0 X - W 2362 0 W -V 2203 0 V - U 1711 0 Chords Tens.Comp. U - T 538 -5 T - S 538 -5 S - R 0 -1814 R - Q 0 -1814 Q - P 54 -792 Maximum Web Forces Per Ply (lbs) Webs Tens.Comp. AC-AB 0 -912 A -AC 0 -896 A -AA 1041 0 AA- B 0 -979 B - Z 612 0 Z - C 0 -578 F - V 0 -591 V - G 534 0 G - U 0 -1141 Webs Tens.Comp. U - H 1599 0 H - S 0 -1811 S - I 1818 0 I - R 0 -2757 I - Q 1433 0 J - Q 56 -532 Q - K 0 -691 K - P 479 0 P - L 0 -422 Loading Criteria (psf) TCLL:40.00 TCDL:10.00 BCLL:0.00 BCDL:5.00 Des Ld:55.00 NCBCLL:10.00 Soffit:2.00 Load Duration: 1.00 Spacing: 24.0 " Wind Criteria Wind Std:NA Speed:NA mph Enclosure: NA Category: NA EXP: NA Kzt: NA Mean Height: NA ft TCDL: NA psf BCDL: NA psf MWFRS Parallel Dist: NA C&C Dist a: NA Loc. from endwall: NA I: NA GCpi: NA Wind Duration: NA Snow Criteria (Pg,Pf in PSF) Pg: NA Ct: NA CAT: NA Pf: NA Ce: NA Lu: NA Cs: NA Snow Duration: NA Building Code: IRC 2021 TPI Std:2014 Rep Fac: Varies by Ld Case FT/RT:12(0)/10(0) Plate Type(s): WAVE Defl/CSI Criteria PP Deflection in loc L/defl L/# VERT(LL):0.202 W 979 360 VERT(CL):0.247 W 801 240 HORZ(LL):0.036 B - - HORZ(TL):0.044 B - - Creep Factor: 2.0 Max TC CSI:0.920 Max BC CSI:0.723 Max Web CSI:0.866 VIEW Ver: 24.01.01A.0510.10 Job Number:TS2207 84 LUMBER Truss Label:F11 Ply: 1 Qty:2 SEQN:120470 SY42 FROM: SC Cust: R 9462 JRef:1YaK94620001 T106 DrwNo:155.25.1734.39960 /BM 06/04/2025 3"12 16'8"4 7'2"4 3" 2'6" (TYP) 2'6"12 2'6"12 2'1"12 1'6"8 3" 1'2"4 7"8 3" 23'10"8 16'8"4 16'8"4 23'10"8 7'2"4 1'8" + A B C D E F G H I J K L M NOPQRSTUVWXYZAAAB AC 1X3 2X4 4X4 4X6 3X4 3X4 3X3W=3X4 3X3 3X4 1X3 3X3 3X3 3X3 3X3 5X6 W=3X4 5X6 6X6 5X12 4X4 1X3 5X8 3X3 3X3 3X3 3X3 3X4 2X4 **WARNING**READ AND FOLLOW ALL NOTES ON THIS DRAW ING! **IMPORTANT**FURNISH THIS DRAW ING TO ALL CONTRACTORS INCLUDING THE INSTALLERSTrusses require extreme care in fabricating, handling, shipping, installing and bracing. Refer to and follow the latest edition of BCSI (BuildingComponent Safety Information, by TPI and SBCA) for safety practices prior to performing these functions. Installers shall provide temporarybracing per BCSI. Unless noted otherwise, top chord shall have properly attached structural sheathing and bottom chord shall have a properlyattached rigid ceiling. Locations shown for permanent lateral restraint of webs shall have continuous lateral restraint (CLR), installed withdiagonal bracing installed on the CLR per BCSI sections B3, B7, or B10, as applicable. Apply plates to each face of truss and position asshown above and on the Joint Details, unless noted otherwise. Refer to drawings 160A-Z for standard plate positions. Refer to job's GeneralNotes page for additional information.Alpine, a division of ITW Building Components Group Inc. shall not be responsible for any deviation from this drawing, any failure to build thetruss in conformance with ANSI/TPI 1, or for handling, shipping, installation and bracing of trusses. A seal on this drawing or cover pagelisting this drawing, indicates acceptance of professional engineering responsibility solely for the design shown. The suitability and use of thisdrawing for any structure is the responsibility of the Building Designer per ANSI/TPI 1 Sec.2. For more information see these web sites: Alpine: alpineitw.com; TPI: tpinst.org; SBCA: sbcacomponents.com; ICC: iccsafe.org; AWC: awc.org 155 Harlem Ave North Building, 4th Floor Glenview, IL 60025 Lumber Top chord: 4x2 SP #2; Bot chord: 4x2 SP #2; Webs: 4x2 SP #3; Special Loads ------(Lumber Dur.Fac.=1.00 / Plate Dur.Fac.=1.00) TC: From 100 plf at 0.12 to 100 plf at 23.88 BC: From 10 plf at 0.00 to 10 plf at 23.88 TC: 650 lb Conc. Load at 12.58,18.00 Loading Bottom chord checked for 10.00 psf non-concurrent live load. Additional Notes + 2x6 continuous strongback. See detail STRBRIBR1014 for bracing and bridging recommendations. Truss must be installed as shown with top chord up. Maximum Reactions (lbs) Gravity Non-Gravity Loc R+/ R-/ Rh / Rw / U / RL AB 897 /-/-/-/-/- R 2911 /-/-/-/-/- N 315 /-162 /-/-/-/- AB Brg Wid = 2.0 Min Req =1.5 (Truss) R Brg Wid = 2.0 Min Req =1.5 (Truss) N Brg Wid = 3.5 Min Req =1.5 (Truss) Bearings AB, R, & N are a rigid surface. Members not listed have forces less than 375# Maximum Top Chord Forces Per Ply (lbs) Chords Tens.Comp. A - B 0 -674 B - C 0 -1676 C - D 0 -2207 D - E 0 -2207 E - F 0 -2294 F - G 0 -1916 Chords Tens.Comp. G - H 0 -1619 H - I 603 0 I - J 934 0 J - K 934 0 K - L 548 -179 Maximum Bot Chord Forces Per Ply (lbs) Chords Tens.Comp. AA- Z 1291 0 Z - Y 2040 0 Y - X 2362 0 X - W 2362 0 W -V 2203 0 V - U 1711 0 Chords Tens.Comp. U - T 538 -5 T - S 538 -5 S - R 0 -1814 R - Q 0 -1814 Q - P 54 -792 Maximum Web Forces Per Ply (lbs) Webs Tens.Comp. AC-AB 0 -912 A -AC 0 -896 A -AA 1041 0 AA- B 0 -979 B - Z 612 0 Z - C 0 -578 F - V 0 -591 V - G 534 0 G - U 0 -1141 Webs Tens.Comp. U - H 1599 0 H - S 0 -1811 S - I 1818 0 I - R 0 -2757 I - Q 1433 0 J - Q 56 -532 Q - K 0 -691 K - P 479 0 P - L 0 -422 Loading Criteria (psf) TCLL:40.00 TCDL:10.00 BCLL:0.00 BCDL:5.00 Des Ld:55.00 NCBCLL:10.00 Soffit:2.00 Load Duration: 1.00 Spacing: 24.0 " Wind Criteria Wind Std:NA Speed:NA mph Enclosure: NA Category: NA EXP: NA Kzt: NA Mean Height: NA ft TCDL: NA psf BCDL: NA psf MWFRS Parallel Dist: NA C&C Dist a: NA Loc. from endwall: NA I: NA GCpi: NA Wind Duration: NA Snow Criteria (Pg,Pf in PSF) Pg: NA Ct: NA CAT: NA Pf: NA Ce: NA Lu: NA Cs: NA Snow Duration: NA Building Code: IRC 2021 TPI Std:2014 Rep Fac: Varies by Ld Case FT/RT:12(0)/10(0) Plate Type(s): WAVE Defl/CSI Criteria PP Deflection in loc L/defl L/# VERT(LL):0.202 W 979 360 VERT(CL):0.247 W 801 240 HORZ(LL):0.036 B - - HORZ(TL):0.044 B - - Creep Factor: 2.0 Max TC CSI:0.920 Max BC CSI:0.723 Max Web CSI:0.866 VIEW Ver: 24.01.01A.0510.10 Job Number:TS2207 84 LUMBER Truss Label:F11 Ply: 1 Qty:2 SEQN:120470 SY42 FROM: SC Cust: R 9462 JRef:1YaK94620001 T106 DrwNo:155.25.1734.39960 /BM 06/04/2025 3"12 16'8"4 7'2"4 3" 2'6" (TYP) 2'6"12 2'6"12 2'1"12 1'6"8 3" 1'2"4 7"8 3" 23'10"8 16'8"4 16'8"4 23'10"8 7'2"4 1'8" + A B C D E F G H I J K L M NOPQRSTUVWXYZAAAB AC 1X3 2X4 4X4 4X6 3X4 3X4 3X3W=3X4 3X3 3X4 1X3 3X3 3X3 3X3 3X3 5X6 W=3X4 5X6 6X6 5X12 4X4 1X3 5X8 3X3 3X3 3X3 3X3 3X4 2X4 $%Lbl:F11?$ 06/04/2025 **WARNING**READ AND FOLLOW ALL NOTES ON THIS DRAW ING! **IMPORTANT**FURNISH THIS DRAW ING TO ALL CONTRACTORS INCLUDING THE INSTALLERSTrusses require extreme care in fabricating, handling, shipping, installing and bracing. Refer to and follow the latest edition of BCSI (BuildingComponent Safety Information, by TPI and SBCA) for safety practices prior to performing these functions. Installers shall provide temporarybracing per BCSI. Unless noted otherwise, top chord shall have properly attached structural sheathing and bottom chord shall have a properlyattached rigid ceiling. Locations shown for permanent lateral restraint of webs shall have continuous lateral restraint (CLR), installed withdiagonal bracing installed on the CLR per BCSI sections B3, B7, or B10, as applicable. Apply plates to each face of truss and position asshown above and on the Joint Details, unless noted otherwise. Refer to drawings 160A-Z for standard plate positions. Refer to job's GeneralNotes page for additional information.Alpine, a division of ITW Building Components Group Inc. shall not be responsible for any deviation from this drawing, any failure to build thetruss in conformance with ANSI/TPI 1, or for handling, shipping, installation and bracing of trusses. A seal on this drawing or cover pagelisting this drawing, indicates acceptance of professional engineering responsibility solely for the design shown. The suitability and use of thisdrawing for any structure is the responsibility of the Building Designer per ANSI/TPI 1 Sec.2. For more information see these web sites: Alpine: alpineitw.com; TPI: tpinst.org; SBCA: sbcacomponents.com; ICC: iccsafe.org; AWC: awc.org 155 Harlem Ave North Building, 4th Floor Glenview, IL 60025 Lumber Top chord: 4x2 SP #2; Bot chord: 4x2 SP #2; Webs: 4x2 SP #3; Special Loads ------(Lumber Dur.Fac.=1.00 / Plate Dur.Fac.=1.00) TC: From 250 plf at 0.12 to 250 plf at 13.25 TC: From 100 plf at 13.25 to 100 plf at 24.29 BC: From 10 plf at 0.12 to 10 plf at 24.29 TC: 946 lb Conc. Load at 0.12 TC: 650 lb Conc. Load at 13.00,18.42 Plating Notes All plates are 5X6 except as noted. Loading Bottom chord checked for 10.00 psf non-concurrent live load. Additional Notes + 2x6 continuous strongback. See detail STRBRIBR1014 for bracing and bridging recommendations. Negative reaction(s) of -484# MAX. from a non-wind load case requires uplift connection. See Maximum Reactions. Truss must be installed as shown with top chord up. Maximum Reactions (lbs) Gravity Non-Gravity Loc R+/ R-/ Rh / Rw / U / RL AD 3044 /-/-/-/-/- T 3976 /-/-/-/-/- O 332 /-484 /-/-/-/- AD Brg Wid = 3.5 Min Req =1.5 (Truss) T Brg Wid = 2.0 Min Req =1.6 (Truss) O Brg Wid = 3.5 Min Req =1.5 (Truss) Bearings AD, T, & O are a rigid surface. Members not listed have forces less than 375# Maximum Top Chord Forces Per Ply (lbs) Chords Tens.Comp. A - B 0 -1674 B - C 0 -3953 C - D 0 -5090 D - E 0 -5082 E - F 0 -5082 F - G 0 -3897 G - H 0 -3119 Chords Tens.Comp. H - I 0 -3119 I - J 990 0 J - K 2323 0 K - L 2323 0 L - M 1446 -244 M - N 448 -174 Maximum Bot Chord Forces Per Ply (lbs) Chords Tens.Comp. AC-AB 3098 0 AB-AA 4796 0 AA- Z 4796 0 Z - Y 5367 0 Y - X 5367 0 X - W 4761 0 W -V 3288 0 Chords Tens.Comp. V - U 1101 0 U - T 0 -3026 T - S 0 -3026 S - R 0 -3026 R - Q 114 -2008 Q - P 328 -926 Maximum Web Forces Per Ply (lbs) Webs Tens.Comp. AD- A 0 -2330 A -AD 13 -971 A -AC 2263 0 AC- B 0 -2169 B -AB 1322 0 AB- C 0 -1305 C - Z 472 0 Z - D 0 -427 D - X 0 -448 X - F 514 0 F - W 0 -1334 W -G 1123 0 G - V 0 -1943 Webs Tens.Comp. V - I 2900 0 I - U 0 -2999 U - J 2956 0 J - T 0 -3660 J - R 1637 0 K - R 9 -514 R - L 0 -1010 L - Q 849 0 Q - M 0 -786 M - P 723 -233 P - N 246 -694 N - O 426 -382 Loading Criteria (psf) TCLL:40.00 TCDL:10.00 BCLL:0.00 BCDL:5.00 Des Ld:55.00 NCBCLL:10.00 Soffit:2.00 Load Duration: 1.00 Spacing: 24.0 " Wind Criteria Wind Std:NA Speed:NA mph Enclosure: NA Category: NA EXP: NA Kzt: NA Mean Height: NA ft TCDL: NA psf BCDL: NA psf MWFRS Parallel Dist: NA C&C Dist a: NA Loc. from endwall: NA I: NA GCpi: NA Wind Duration: NA Snow Criteria (Pg,Pf in PSF) Pg: NA Ct: NA CAT: NA Pf: NA Ce: NA Lu: NA Cs: NA Snow Duration: NA Building Code: IRC 2021 TPI Std:2014 Rep Fac: Varies by Ld Case FT/RT:12(0)/10(0) Plate Type(s): WAVE Defl/CSI Criteria PP Deflection in loc L/defl L/# VERT(LL):0.234 D 854 360 VERT(CL):0.319 D 626 240 HORZ(LL):0.038 A - - HORZ(TL):0.051 A - - Creep Factor: 2.0 Max TC CSI:0.730 Max BC CSI:0.872 Max Web CSI:0.780 VIEW Ver: 24.01.01A.0510.10 Job Number:TS2207 84 LUMBER Truss Label:F12 Ply: 1 Qty:1 SEQN:120474 SY42 FROM: SC Cust: R 9462 JRef:1YaK94620001 T107 DrwNo:155.25.1734.42223 /BM 06/04/2025 3"8 3"12 5"16'8"4 7'2"4 1"8 17'6"6'8" 3" 0"8 2"8 2'6" (TYP) 2'6"12 2'6"12 2'2"4 3" 1'2"4 7"8 3" 24'3"8 13'0"12 13'0"12 13'3"2 2"6 15'8"12 2'5"10 15'10"15 2"3 17'1"4 1'2"5 24'3"8 7'2"4 1'8" 1"8 + A B C D E F G H I J K L M N OPQRSTUVWXYZAAABACAD 1X3 1X3 6X12 6X8 6X6 6X6 4X6 W=3X64X4 4X4 3X6 4X4 W=3X44X6 5X6 4X6 6X6 W=3X46X8 7X8 7X12 W=3X4 3X6 6X8 4X6 4X6 4X4 3X4 **WARNING**READ AND FOLLOW ALL NOTES ON THIS DRAW ING! **IMPORTANT**FURNISH THIS DRAW ING TO ALL CONTRACTORS INCLUDING THE INSTALLERSTrusses require extreme care in fabricating, handling, shipping, installing and bracing. Refer to and follow the latest edition of BCSI (BuildingComponent Safety Information, by TPI and SBCA) for safety practices prior to performing these functions. Installers shall provide temporarybracing per BCSI. Unless noted otherwise, top chord shall have properly attached structural sheathing and bottom chord shall have a properlyattached rigid ceiling. Locations shown for permanent lateral restraint of webs shall have continuous lateral restraint (CLR), installed withdiagonal bracing installed on the CLR per BCSI sections B3, B7, or B10, as applicable. Apply plates to each face of truss and position asshown above and on the Joint Details, unless noted otherwise. Refer to drawings 160A-Z for standard plate positions. Refer to job's GeneralNotes page for additional information.Alpine, a division of ITW Building Components Group Inc. shall not be responsible for any deviation from this drawing, any failure to build thetruss in conformance with ANSI/TPI 1, or for handling, shipping, installation and bracing of trusses. A seal on this drawing or cover pagelisting this drawing, indicates acceptance of professional engineering responsibility solely for the design shown. The suitability and use of thisdrawing for any structure is the responsibility of the Building Designer per ANSI/TPI 1 Sec.2. For more information see these web sites: Alpine: alpineitw.com; TPI: tpinst.org; SBCA: sbcacomponents.com; ICC: iccsafe.org; AWC: awc.org 155 Harlem Ave North Building, 4th Floor Glenview, IL 60025 Lumber Top chord: 4x2 SP #2; Bot chord: 4x2 SP #2; Webs: 4x2 SP #3; Special Loads ------(Lumber Dur.Fac.=1.00 / Plate Dur.Fac.=1.00) TC: From 250 plf at 0.12 to 250 plf at 13.25 TC: From 100 plf at 13.25 to 100 plf at 24.29 BC: From 10 plf at 0.12 to 10 plf at 24.29 TC: 946 lb Conc. Load at 0.12 TC: 650 lb Conc. Load at 13.00,18.42 Plating Notes All plates are 5X6 except as noted. Loading Bottom chord checked for 10.00 psf non-concurrent live load. Additional Notes + 2x6 continuous strongback. See detail STRBRIBR1014 for bracing and bridging recommendations. Negative reaction(s) of -484# MAX. from a non-wind load case requires uplift connection. See Maximum Reactions. Truss must be installed as shown with top chord up. Maximum Reactions (lbs) Gravity Non-Gravity Loc R+/ R-/ Rh / Rw / U / RL AD 3044 /-/-/-/-/- T 3976 /-/-/-/-/- O 332 /-484 /-/-/-/- AD Brg Wid = 3.5 Min Req =1.5 (Truss) T Brg Wid = 2.0 Min Req =1.6 (Truss) O Brg Wid = 3.5 Min Req =1.5 (Truss) Bearings AD, T, & O are a rigid surface. Members not listed have forces less than 375# Maximum Top Chord Forces Per Ply (lbs) Chords Tens.Comp. A - B 0 -1674 B - C 0 -3953 C - D 0 -5090 D - E 0 -5082 E - F 0 -5082 F - G 0 -3897 G - H 0 -3119 Chords Tens.Comp. H - I 0 -3119 I - J 990 0 J - K 2323 0 K - L 2323 0 L - M 1446 -244 M - N 448 -174 Maximum Bot Chord Forces Per Ply (lbs) Chords Tens.Comp. AC-AB 3098 0 AB-AA 4796 0 AA- Z 4796 0 Z - Y 5367 0 Y - X 5367 0 X - W 4761 0 W -V 3288 0 Chords Tens.Comp. V - U 1101 0 U - T 0 -3026 T - S 0 -3026 S - R 0 -3026 R - Q 114 -2008 Q - P 328 -926 Maximum Web Forces Per Ply (lbs) Webs Tens.Comp. AD- A 0 -2330 A -AD 13 -971 A -AC 2263 0 AC- B 0 -2169 B -AB 1322 0 AB- C 0 -1305 C - Z 472 0 Z - D 0 -427 D - X 0 -448 X - F 514 0 F - W 0 -1334 W -G 1123 0 G - V 0 -1943 Webs Tens.Comp. V - I 2900 0 I - U 0 -2999 U - J 2956 0 J - T 0 -3660 J - R 1637 0 K - R 9 -514 R - L 0 -1010 L - Q 849 0 Q - M 0 -786 M - P 723 -233 P - N 246 -694 N - O 426 -382 Loading Criteria (psf) TCLL:40.00 TCDL:10.00 BCLL:0.00 BCDL:5.00 Des Ld:55.00 NCBCLL:10.00 Soffit:2.00 Load Duration: 1.00 Spacing: 24.0 " Wind Criteria Wind Std:NA Speed:NA mph Enclosure: NA Category: NA EXP: NA Kzt: NA Mean Height: NA ft TCDL: NA psf BCDL: NA psf MWFRS Parallel Dist: NA C&C Dist a: NA Loc. from endwall: NA I: NA GCpi: NA Wind Duration: NA Snow Criteria (Pg,Pf in PSF) Pg: NA Ct: NA CAT: NA Pf: NA Ce: NA Lu: NA Cs: NA Snow Duration: NA Building Code: IRC 2021 TPI Std:2014 Rep Fac: Varies by Ld Case FT/RT:12(0)/10(0) Plate Type(s): WAVE Defl/CSI Criteria PP Deflection in loc L/defl L/# VERT(LL):0.234 D 854 360 VERT(CL):0.319 D 626 240 HORZ(LL):0.038 A - - HORZ(TL):0.051 A - - Creep Factor: 2.0 Max TC CSI:0.730 Max BC CSI:0.872 Max Web CSI:0.780 VIEW Ver: 24.01.01A.0510.10 Job Number:TS2207 84 LUMBER Truss Label:F12 Ply: 1 Qty:1 SEQN:120474 SY42 FROM: SC Cust: R 9462 JRef:1YaK94620001 T107 DrwNo:155.25.1734.42223 /BM 06/04/2025 3"8 3"12 5"16'8"4 7'2"4 1"8 17'6"6'8" 3" 0"8 2"8 2'6" (TYP) 2'6"12 2'6"12 2'2"4 3" 1'2"4 7"8 3" 24'3"8 13'0"12 13'0"12 13'3"2 2"6 15'8"12 2'5"10 15'10"15 2"3 17'1"4 1'2"5 24'3"8 7'2"4 1'8" 1"8 + A B C D E F G H I J K L M N OPQRSTUVWXYZAAABACAD 1X3 1X3 6X12 6X8 6X6 6X6 4X6 W=3X64X4 4X4 3X6 4X4 W=3X44X6 5X6 4X6 6X6 W=3X46X8 7X8 7X12 W=3X4 3X6 6X8 4X6 4X6 4X4 3X4 $%Lbl:F12?$ 06/04/2025 **WARNING**READ AND FOLLOW ALL NOTES ON THIS DRAW ING! **IMPORTANT**FURNISH THIS DRAW ING TO ALL CONTRACTORS INCLUDING THE INSTALLERSTrusses require extreme care in fabricating, handling, shipping, installing and bracing. Refer to and follow the latest edition of BCSI (BuildingComponent Safety Information, by TPI and SBCA) for safety practices prior to performing these functions. Installers shall provide temporarybracing per BCSI. Unless noted otherwise, top chord shall have properly attached structural sheathing and bottom chord shall have a properlyattached rigid ceiling. Locations shown for permanent lateral restraint of webs shall have continuous lateral restraint (CLR), installed withdiagonal bracing installed on the CLR per BCSI sections B3, B7, or B10, as applicable. Apply plates to each face of truss and position asshown above and on the Joint Details, unless noted otherwise. Refer to drawings 160A-Z for standard plate positions. Refer to job's GeneralNotes page for additional information.Alpine, a division of ITW Building Components Group Inc. shall not be responsible for any deviation from this drawing, any failure to build thetruss in conformance with ANSI/TPI 1, or for handling, shipping, installation and bracing of trusses. A seal on this drawing or cover pagelisting this drawing, indicates acceptance of professional engineering responsibility solely for the design shown. The suitability and use of thisdrawing for any structure is the responsibility of the Building Designer per ANSI/TPI 1 Sec.2. For more information see these web sites: Alpine: alpineitw.com; TPI: tpinst.org; SBCA: sbcacomponents.com; ICC: iccsafe.org; AWC: awc.org 155 Harlem Ave North Building, 4th Floor Glenview, IL 60025 Lumber Top chord: 4x2 SP #2; Bot chord: 4x2 SP #2; Webs: 4x2 SP #3; Special Loads ------(Lumber Dur.Fac.=1.00 / Plate Dur.Fac.=1.00) TC: From 100 plf at 0.12 to 100 plf at 24.29 BC: From 10 plf at 0.12 to 10 plf at 24.29 TC: 946 lb Conc. Load at 0.12 TC: 650 lb Conc. Load at 13.00,18.42 Loading Bottom chord checked for 10.00 psf non-concurrent live load. Additional Notes + 2x6 continuous strongback. See detail STRBRIBR1014 for bracing and bridging recommendations. Negative reaction(s) of -246# MAX. from a non-wind load case requires uplift connection. See Maximum Reactions. Truss must be installed as shown with top chord up. Maximum Reactions (lbs) Gravity Non-Gravity Loc R+/ R-/ Rh / Rw / U / RL AC 1920 /-/-/-/-/- T 2901 /-/-/-/-/- O 397 /-246 /-/-/-/- AC Brg Wid = 3.5 Min Req =1.5 (Truss) T Brg Wid = 2.0 Min Req =1.5 (Truss) O Brg Wid = 3.5 Min Req =1.5 (Truss) Bearings AC, T, & O are a rigid surface. Members not listed have forces less than 375# Maximum Top Chord Forces Per Ply (lbs) Chords Tens.Comp. B - C 26 -602 C - D 0 -1615 D - E 0 -2167 E - F 0 -2297 F - G 0 -2297 G - H 0 -1978 Chords Tens.Comp. H - I 0 -1693 I - J 598 0 J - K 1252 -186 K - L 1252 -186 L - M 751 -382 Maximum Bot Chord Forces Per Ply (lbs) Chords Tens.Comp. AB-AA 1212 0 AA- Z 1992 0 Z - Y 2333 0 Y - X 2333 0 X - W 2237 0 W -V 1783 0 Chords Tens.Comp. V - U 646 0 U - T 0 -1802 T - S 0 -1802 S - R 0 -1802 R - Q 321 -1066 Q - P 412 -464 Maximum Web Forces Per Ply (lbs) Webs Tens.Comp. A -AC 28 -846 AC- B 0 -996 B -AB 954 0 AB- C 0 -996 C -AA 675 0 AA- D 0 -632 G - W 0 -443 W -H 403 0 H - V 0 -1136 V - I 1590 0 Webs Tens.Comp. I - U 0 -1802 U - J 1810 0 J - T 0 -2748 J - R 1430 0 K - R 8 -587 R - L 0 -688 L - Q 500 0 Q - M 0 -455 M - P 382 -319 N - O 253 -375 Loading Criteria (psf) TCLL:40.00 TCDL:10.00 BCLL:0.00 BCDL:5.00 Des Ld:55.00 NCBCLL:10.00 Soffit:2.00 Load Duration: 1.00 Spacing: 24.0 " Wind Criteria Wind Std:NA Speed:NA mph Enclosure: NA Category: NA EXP: NA Kzt: NA Mean Height: NA ft TCDL: NA psf BCDL: NA psf MWFRS Parallel Dist: NA C&C Dist a: NA Loc. from endwall: NA I: NA GCpi: NA Wind Duration: NA Snow Criteria (Pg,Pf in PSF) Pg: NA Ct: NA CAT: NA Pf: NA Ce: NA Lu: NA Cs: NA Snow Duration: NA Building Code: IRC 2021 TPI Std:2014 Rep Fac: Varies by Ld Case FT/RT:12(0)/10(0) Plate Type(s): WAVE Defl/CSI Criteria PP Deflection in loc L/defl L/# VERT(LL):0.177 X 999 360 VERT(CL):0.245 X 813 240 HORZ(LL):0.033 A - - HORZ(TL):0.046 A - - Creep Factor: 2.0 Max TC CSI:0.916 Max BC CSI:0.723 Max Web CSI:0.862 VIEW Ver: 24.01.01A.0510.10 Job Number:TS2207 84 LUMBER Truss Label:F13 Ply: 1 Qty:3 SEQN:120477 SY42 FROM: SC Cust: R 9462 JRef:1YaK94620001 T108 DrwNo:155.25.1734.44203 /BM 06/04/2025 3"8 3"8 5"16'8"4 7'2"4 6" 2'6" (TYP) 2'6"12 2'6"12 2'2"4 1'6"8 3" 1'2"4 7"8 3" 24'3"8 17'1"4 17'1"4 24'3"8 7'2"4 1'8" + A B C D E F G H I J K L M N OPQRSTUVWXYZAAABACAD 1X3 1X3 3X3 1X33X3 4X4 4X4 3X4 3X4 3X3 3X3 3X4 1X3 3X3 W=3X43X3 3X3 3X3 5X6 5X6 6X6 5X12 4X4W=3X4 1X3 5X8 3X3 3X3 3X3 3X3 3X4 2X4 **WARNING**READ AND FOLLOW ALL NOTES ON THIS DRAW ING! **IMPORTANT**FURNISH THIS DRAW ING TO ALL CONTRACTORS INCLUDING THE INSTALLERSTrusses require extreme care in fabricating, handling, shipping, installing and bracing. Refer to and follow the latest edition of BCSI (BuildingComponent Safety Information, by TPI and SBCA) for safety practices prior to performing these functions. Installers shall provide temporarybracing per BCSI. Unless noted otherwise, top chord shall have properly attached structural sheathing and bottom chord shall have a properlyattached rigid ceiling. Locations shown for permanent lateral restraint of webs shall have continuous lateral restraint (CLR), installed withdiagonal bracing installed on the CLR per BCSI sections B3, B7, or B10, as applicable. Apply plates to each face of truss and position asshown above and on the Joint Details, unless noted otherwise. Refer to drawings 160A-Z for standard plate positions. Refer to job's GeneralNotes page for additional information.Alpine, a division of ITW Building Components Group Inc. shall not be responsible for any deviation from this drawing, any failure to build thetruss in conformance with ANSI/TPI 1, or for handling, shipping, installation and bracing of trusses. A seal on this drawing or cover pagelisting this drawing, indicates acceptance of professional engineering responsibility solely for the design shown. The suitability and use of thisdrawing for any structure is the responsibility of the Building Designer per ANSI/TPI 1 Sec.2. For more information see these web sites: Alpine: alpineitw.com; TPI: tpinst.org; SBCA: sbcacomponents.com; ICC: iccsafe.org; AWC: awc.org 155 Harlem Ave North Building, 4th Floor Glenview, IL 60025 Lumber Top chord: 4x2 SP #2; Bot chord: 4x2 SP #2; Webs: 4x2 SP #3; Special Loads ------(Lumber Dur.Fac.=1.00 / Plate Dur.Fac.=1.00) TC: From 100 plf at 0.12 to 100 plf at 24.29 BC: From 10 plf at 0.12 to 10 plf at 24.29 TC: 946 lb Conc. Load at 0.12 TC: 650 lb Conc. Load at 13.00,18.42 Loading Bottom chord checked for 10.00 psf non-concurrent live load. Additional Notes + 2x6 continuous strongback. See detail STRBRIBR1014 for bracing and bridging recommendations. Negative reaction(s) of -246# MAX. from a non-wind load case requires uplift connection. See Maximum Reactions. Truss must be installed as shown with top chord up. Maximum Reactions (lbs) Gravity Non-Gravity Loc R+/ R-/ Rh / Rw / U / RL AC 1920 /-/-/-/-/- T 2901 /-/-/-/-/- O 397 /-246 /-/-/-/- AC Brg Wid = 3.5 Min Req =1.5 (Truss) T Brg Wid = 2.0 Min Req =1.5 (Truss) O Brg Wid = 3.5 Min Req =1.5 (Truss) Bearings AC, T, & O are a rigid surface. Members not listed have forces less than 375# Maximum Top Chord Forces Per Ply (lbs) Chords Tens.Comp. B - C 26 -602 C - D 0 -1615 D - E 0 -2167 E - F 0 -2297 F - G 0 -2297 G - H 0 -1978 Chords Tens.Comp. H - I 0 -1693 I - J 598 0 J - K 1252 -186 K - L 1252 -186 L - M 751 -382 Maximum Bot Chord Forces Per Ply (lbs) Chords Tens.Comp. AB-AA 1212 0 AA- Z 1992 0 Z - Y 2333 0 Y - X 2333 0 X - W 2237 0 W -V 1783 0 Chords Tens.Comp. V - U 646 0 U - T 0 -1802 T - S 0 -1802 S - R 0 -1802 R - Q 321 -1066 Q - P 412 -464 Maximum Web Forces Per Ply (lbs) Webs Tens.Comp. A -AC 28 -846 AC- B 0 -996 B -AB 954 0 AB- C 0 -996 C -AA 675 0 AA- D 0 -632 G - W 0 -443 W -H 403 0 H - V 0 -1136 V - I 1590 0 Webs Tens.Comp. I - U 0 -1802 U - J 1810 0 J - T 0 -2748 J - R 1430 0 K - R 8 -587 R - L 0 -688 L - Q 500 0 Q - M 0 -455 M - P 382 -319 N - O 253 -375 Loading Criteria (psf) TCLL:40.00 TCDL:10.00 BCLL:0.00 BCDL:5.00 Des Ld:55.00 NCBCLL:10.00 Soffit:2.00 Load Duration: 1.00 Spacing: 24.0 " Wind Criteria Wind Std:NA Speed:NA mph Enclosure: NA Category: NA EXP: NA Kzt: NA Mean Height: NA ft TCDL: NA psf BCDL: NA psf MWFRS Parallel Dist: NA C&C Dist a: NA Loc. from endwall: NA I: NA GCpi: NA Wind Duration: NA Snow Criteria (Pg,Pf in PSF) Pg: NA Ct: NA CAT: NA Pf: NA Ce: NA Lu: NA Cs: NA Snow Duration: NA Building Code: IRC 2021 TPI Std:2014 Rep Fac: Varies by Ld Case FT/RT:12(0)/10(0) Plate Type(s): WAVE Defl/CSI Criteria PP Deflection in loc L/defl L/# VERT(LL):0.177 X 999 360 VERT(CL):0.245 X 813 240 HORZ(LL):0.033 A - - HORZ(TL):0.046 A - - Creep Factor: 2.0 Max TC CSI:0.916 Max BC CSI:0.723 Max Web CSI:0.862 VIEW Ver: 24.01.01A.0510.10 Job Number:TS2207 84 LUMBER Truss Label:F13 Ply: 1 Qty:3 SEQN:120477 SY42 FROM: SC Cust: R 9462 JRef:1YaK94620001 T108 DrwNo:155.25.1734.44203 /BM 06/04/2025 3"8 3"8 5"16'8"4 7'2"4 6" 2'6" (TYP) 2'6"12 2'6"12 2'2"4 1'6"8 3" 1'2"4 7"8 3" 24'3"8 17'1"4 17'1"4 24'3"8 7'2"4 1'8" + A B C D E F G H I J K L M N OPQRSTUVWXYZAAABACAD 1X3 1X3 3X3 1X33X3 4X4 4X4 3X4 3X4 3X3 3X3 3X4 1X3 3X3 W=3X43X3 3X3 3X3 5X6 5X6 6X6 5X12 4X4W=3X4 1X3 5X8 3X3 3X3 3X3 3X3 3X4 2X4 $%Lbl:F13?$ 06/04/2025 **WARNING**READ AND FOLLOW ALL NOTES ON THIS DRAW ING! **IMPORTANT**FURNISH THIS DRAW ING TO ALL CONTRACTORS INCLUDING THE INSTALLERSTrusses require extreme care in fabricating, handling, shipping, installing and bracing. Refer to and follow the latest edition of BCSI (BuildingComponent Safety Information, by TPI and SBCA) for safety practices prior to performing these functions. Installers shall provide temporarybracing per BCSI. Unless noted otherwise, top chord shall have properly attached structural sheathing and bottom chord shall have a properlyattached rigid ceiling. Locations shown for permanent lateral restraint of webs shall have continuous lateral restraint (CLR), installed withdiagonal bracing installed on the CLR per BCSI sections B3, B7, or B10, as applicable. Apply plates to each face of truss and position asshown above and on the Joint Details, unless noted otherwise. Refer to drawings 160A-Z for standard plate positions. Refer to job's GeneralNotes page for additional information.Alpine, a division of ITW Building Components Group Inc. shall not be responsible for any deviation from this drawing, any failure to build thetruss in conformance with ANSI/TPI 1, or for handling, shipping, installation and bracing of trusses. A seal on this drawing or cover pagelisting this drawing, indicates acceptance of professional engineering responsibility solely for the design shown. The suitability and use of thisdrawing for any structure is the responsibility of the Building Designer per ANSI/TPI 1 Sec.2. For more information see these web sites: Alpine: alpineitw.com; TPI: tpinst.org; SBCA: sbcacomponents.com; ICC: iccsafe.org; AWC: awc.org 155 Harlem Ave North Building, 4th Floor Glenview, IL 60025 Lumber Top chord: 4x2 SP #2; Bot chord: 4x2 SP #2; Webs: 4x2 SP #3; Special Loads ------(Lumber Dur.Fac.=1.00 / Plate Dur.Fac.=1.00) TC: From 100 plf at 0.12 to 100 plf at 13.00 TC: From 325 plf at 13.00 to 325 plf at 23.10 BC: From 10 plf at 0.12 to 10 plf at 23.10 TC: 946 lb Conc. Load at 0.12 TC: 650 lb Conc. Load at 13.00,18.42 Plating Notes All plates are W =3X4 except as noted. Loading Bottom chord checked for 10.00 psf non-concurrent live load. Additional Notes + 2x6 continuous strongback. See detail STRBRIBR1014 for bracing and bridging recommendations. Negative reaction(s) of -254# MAX. from a non-wind load case requires uplift connection. See Maximum Reactions. Truss must be installed as shown with top chord up. Maximum Reactions (lbs) Gravity Non-Gravity Loc R+/ R-/ Rh / Rw / U / RL AC 2000 /-/-/-/-/- S 4410 /-/-/-/-/- N 943 /-254 /-/-/-/- AC Brg Wid = 3.5 Min Req =1.5 (Truss) S Brg Wid = 2.0 Min Req =1.9 (Truss) N Brg Wid = 3.5 Min Req =1.5 (Truss) Bearings AC, S, & N are a rigid surface. Members not listed have forces less than 375# Maximum Top Chord Forces Per Ply (lbs) Chords Tens.Comp. A - B 0 -825 B - C 0 -2076 C - D 0 -2848 D - E 0 -3140 E - F 0 -3140 F - G 0 -2912 Chords Tens.Comp. G - H 0 -2667 H - I 0 -2667 J - K 1118 -245 K - L 882 -541 L - M 251 -461 Maximum Bot Chord Forces Per Ply (lbs) Chords Tens.Comp. AB-AA 1562 0 AA- Z 2572 0 Z - Y 2572 0 Y - X 3111 0 X - W 3111 0 W -V 3132 0 V - U 2765 0 Chords Tens.Comp. U - T 1475 0 T - S 0 -1953 S - R 0 -1953 R - Q 0 -1953 Q - P 364 -1069 P - O 866 -537 Maximum Web Forces Per Ply (lbs) Webs Tens.Comp. AC- A 0 -1186 A -AC 14 -959 A -AB 1180 0 AB- B 0 -1116 B -AA 793 0 AA- C 0 -766 C - Y 430 0 Y - D 0 -400 F - V 8 -406 G - U 0 -1119 U - I 1686 0 Webs Tens.Comp. I - T 0 -2574 T - J 2477 0 J - S 0 -4076 J - Q 1889 0 Q - K 0 -1619 K - P 779 0 P - L 0 -895 L - O 432 -612 O - M 635 -391 M - N 211 -1160 Loading Criteria (psf) TCLL:40.00 TCDL:10.00 BCLL:0.00 BCDL:5.00 Des Ld:55.00 NCBCLL:10.00 Soffit:2.00 Load Duration: 1.00 Spacing: 24.0 " Wind Criteria Wind Std:NA Speed:NA mph Enclosure: NA Category: NA EXP: NA Kzt: NA Mean Height: NA ft TCDL: NA psf BCDL: NA psf MWFRS Parallel Dist: NA C&C Dist a: NA Loc. from endwall: NA I: NA GCpi: NA Wind Duration: NA Snow Criteria (Pg,Pf in PSF) Pg: NA Ct: NA CAT: NA Pf: NA Ce: NA Lu: NA Cs: NA Snow Duration: NA Building Code: IRC 2021 TPI Std:2014 Rep Fac: Varies by Ld Case FT/RT:12(0)/10(0) Plate Type(s): WAVE Defl/CSI Criteria PP Deflection in loc L/defl L/# VERT(LL):0.152 W 999 360 VERT(CL):0.197 W 999 240 HORZ(LL):0.023 A - - HORZ(TL):0.029 A - - Creep Factor: 2.0 Max TC CSI:0.783 Max BC CSI:0.521 Max Web CSI:0.899 VIEW Ver: 24.01.01A.0510.10 Job Number:TS2207 84 LUMBER Truss Label:F14 Ply: 1 Qty:1 SEQN:120481 SY42 FROM: SC Cust: R 9462 JRef:1YaK94620001 T109 DrwNo:155.25.1734.46230 /BM 06/04/2025 3"8 3"12 5"16'8"4 6' 1"8 17'6"5'5"12 3" 0"8 2"8 2'6" (TYP) 2'6"12 2'6"12 2'2"4 3"1'10"8 3" 23'1"4 13'0"12 13'0"12 13'3"2 2"6 15'8"12 2'5"10 15'10"15 2"3 17'1"4 1'2"5 23'1"4 6' 1'8" 1"8 + A B C D E F G H I J K L M NOPQRSTUVWXYZAAABAC 1X3 1X34X6 5X12 5X6 4X6 4X6 4X4 3X4 4X4 3X6 3X4 3X4 3X4 3X4 5X6 6X6 6X8 7X12 5X6 5X8 3X6 3X6 4X4 4X6 5X6 3X4 **WARNING**READ AND FOLLOW ALL NOTES ON THIS DRAW ING! **IMPORTANT**FURNISH THIS DRAW ING TO ALL CONTRACTORS INCLUDING THE INSTALLERSTrusses require extreme care in fabricating, handling, shipping, installing and bracing. Refer to and follow the latest edition of BCSI (BuildingComponent Safety Information, by TPI and SBCA) for safety practices prior to performing these functions. Installers shall provide temporarybracing per BCSI. Unless noted otherwise, top chord shall have properly attached structural sheathing and bottom chord shall have a properlyattached rigid ceiling. Locations shown for permanent lateral restraint of webs shall have continuous lateral restraint (CLR), installed withdiagonal bracing installed on the CLR per BCSI sections B3, B7, or B10, as applicable. Apply plates to each face of truss and position asshown above and on the Joint Details, unless noted otherwise. Refer to drawings 160A-Z for standard plate positions. Refer to job's GeneralNotes page for additional information.Alpine, a division of ITW Building Components Group Inc. shall not be responsible for any deviation from this drawing, any failure to build thetruss in conformance with ANSI/TPI 1, or for handling, shipping, installation and bracing of trusses. A seal on this drawing or cover pagelisting this drawing, indicates acceptance of professional engineering responsibility solely for the design shown. The suitability and use of thisdrawing for any structure is the responsibility of the Building Designer per ANSI/TPI 1 Sec.2. For more information see these web sites: Alpine: alpineitw.com; TPI: tpinst.org; SBCA: sbcacomponents.com; ICC: iccsafe.org; AWC: awc.org 155 Harlem Ave North Building, 4th Floor Glenview, IL 60025 Lumber Top chord: 4x2 SP #2; Bot chord: 4x2 SP #2; Webs: 4x2 SP #3; Special Loads ------(Lumber Dur.Fac.=1.00 / Plate Dur.Fac.=1.00) TC: From 100 plf at 0.12 to 100 plf at 13.00 TC: From 325 plf at 13.00 to 325 plf at 23.10 BC: From 10 plf at 0.12 to 10 plf at 23.10 TC: 946 lb Conc. Load at 0.12 TC: 650 lb Conc. Load at 13.00,18.42 Plating Notes All plates are W =3X4 except as noted. Loading Bottom chord checked for 10.00 psf non-concurrent live load. Additional Notes + 2x6 continuous strongback. See detail STRBRIBR1014 for bracing and bridging recommendations. Negative reaction(s) of -254# MAX. from a non-wind load case requires uplift connection. See Maximum Reactions. Truss must be installed as shown with top chord up. Maximum Reactions (lbs) Gravity Non-Gravity Loc R+/ R-/ Rh / Rw / U / RL AC 2000 /-/-/-/-/- S 4410 /-/-/-/-/- N 943 /-254 /-/-/-/- AC Brg Wid = 3.5 Min Req =1.5 (Truss) S Brg Wid = 2.0 Min Req =1.9 (Truss) N Brg Wid = 3.5 Min Req =1.5 (Truss) Bearings AC, S, & N are a rigid surface. Members not listed have forces less than 375# Maximum Top Chord Forces Per Ply (lbs) Chords Tens.Comp. A - B 0 -825 B - C 0 -2076 C - D 0 -2848 D - E 0 -3140 E - F 0 -3140 F - G 0 -2912 Chords Tens.Comp. G - H 0 -2667 H - I 0 -2667 J - K 1118 -245 K - L 882 -541 L - M 251 -461 Maximum Bot Chord Forces Per Ply (lbs) Chords Tens.Comp. AB-AA 1562 0 AA- Z 2572 0 Z - Y 2572 0 Y - X 3111 0 X - W 3111 0 W -V 3132 0 V - U 2765 0 Chords Tens.Comp. U - T 1475 0 T - S 0 -1953 S - R 0 -1953 R - Q 0 -1953 Q - P 364 -1069 P - O 866 -537 Maximum Web Forces Per Ply (lbs) Webs Tens.Comp. AC- A 0 -1186 A -AC 14 -959 A -AB 1180 0 AB- B 0 -1116 B -AA 793 0 AA- C 0 -766 C - Y 430 0 Y - D 0 -400 F - V 8 -406 G - U 0 -1119 U - I 1686 0 Webs Tens.Comp. I - T 0 -2574 T - J 2477 0 J - S 0 -4076 J - Q 1889 0 Q - K 0 -1619 K - P 779 0 P - L 0 -895 L - O 432 -612 O - M 635 -391 M - N 211 -1160 Loading Criteria (psf) TCLL:40.00 TCDL:10.00 BCLL:0.00 BCDL:5.00 Des Ld:55.00 NCBCLL:10.00 Soffit:2.00 Load Duration: 1.00 Spacing: 24.0 " Wind Criteria Wind Std:NA Speed:NA mph Enclosure: NA Category: NA EXP: NA Kzt: NA Mean Height: NA ft TCDL: NA psf BCDL: NA psf MWFRS Parallel Dist: NA C&C Dist a: NA Loc. from endwall: NA I: NA GCpi: NA Wind Duration: NA Snow Criteria (Pg,Pf in PSF) Pg: NA Ct: NA CAT: NA Pf: NA Ce: NA Lu: NA Cs: NA Snow Duration: NA Building Code: IRC 2021 TPI Std:2014 Rep Fac: Varies by Ld Case FT/RT:12(0)/10(0) Plate Type(s): WAVE Defl/CSI Criteria PP Deflection in loc L/defl L/# VERT(LL):0.152 W 999 360 VERT(CL):0.197 W 999 240 HORZ(LL):0.023 A - - HORZ(TL):0.029 A - - Creep Factor: 2.0 Max TC CSI:0.783 Max BC CSI:0.521 Max Web CSI:0.899 VIEW Ver: 24.01.01A.0510.10 Job Number:TS2207 84 LUMBER Truss Label:F14 Ply: 1 Qty:1 SEQN:120481 SY42 FROM: SC Cust: R 9462 JRef:1YaK94620001 T109 DrwNo:155.25.1734.46230 /BM 06/04/2025 3"8 3"12 5"16'8"4 6' 1"8 17'6"5'5"12 3" 0"8 2"8 2'6" (TYP) 2'6"12 2'6"12 2'2"4 3"1'10"8 3" 23'1"4 13'0"12 13'0"12 13'3"2 2"6 15'8"12 2'5"10 15'10"15 2"3 17'1"4 1'2"5 23'1"4 6' 1'8" 1"8 + A B C D E F G H I J K L M NOPQRSTUVWXYZAAABAC 1X3 1X34X6 5X12 5X6 4X6 4X6 4X4 3X4 4X4 3X6 3X4 3X4 3X4 3X4 5X6 6X6 6X8 7X12 5X6 5X8 3X6 3X6 4X4 4X6 5X6 3X4 $%Lbl:F14?$ 06/04/2025 **WARNING**READ AND FOLLOW ALL NOTES ON THIS DRAW ING! **IMPORTANT**FURNISH THIS DRAW ING TO ALL CONTRACTORS INCLUDING THE INSTALLERSTrusses require extreme care in fabricating, handling, shipping, installing and bracing. Refer to and follow the latest edition of BCSI (BuildingComponent Safety Information, by TPI and SBCA) for safety practices prior to performing these functions. Installers shall provide temporarybracing per BCSI. Unless noted otherwise, top chord shall have properly attached structural sheathing and bottom chord shall have a properlyattached rigid ceiling. Locations shown for permanent lateral restraint of webs shall have continuous lateral restraint (CLR), installed withdiagonal bracing installed on the CLR per BCSI sections B3, B7, or B10, as applicable. Apply plates to each face of truss and position asshown above and on the Joint Details, unless noted otherwise. Refer to drawings 160A-Z for standard plate positions. Refer to job's GeneralNotes page for additional information.Alpine, a division of ITW Building Components Group Inc. shall not be responsible for any deviation from this drawing, any failure to build thetruss in conformance with ANSI/TPI 1, or for handling, shipping, installation and bracing of trusses. A seal on this drawing or cover pagelisting this drawing, indicates acceptance of professional engineering responsibility solely for the design shown. The suitability and use of thisdrawing for any structure is the responsibility of the Building Designer per ANSI/TPI 1 Sec.2. For more information see these web sites: Alpine: alpineitw.com; TPI: tpinst.org; SBCA: sbcacomponents.com; ICC: iccsafe.org; AWC: awc.org 155 Harlem Ave North Building, 4th Floor Glenview, IL 60025 Lumber Top chord: 4x2 SP #2; Bot chord: 4x2 SP #2; Webs: 4x2 SP #3; Special Loads ------(Lumber Dur.Fac.=1.00 / Plate Dur.Fac.=1.00) TC: From 325 plf at 0.00 to 325 plf at 3.17 TC: From 100 plf at 3.17 to 100 plf at 8.67 BC: From 10 plf at 0.00 to 10 plf at 8.67 Loading Bottom chord checked for 10.00 psf non-concurrent live load. Additional Notes Truss must be installed as shown with top chord up. Maximum Reactions (lbs) Gravity Non-Gravity Loc R+/ R-/ Rh / Rw / U / RL K 1062 /-/-/-/-/- F 604 /-/-/-/-/- K Brg Wid = 2.0 Min Req =1.5 (Truss) F Brg Wid = 3.5 Min Req =1.5 (Truss) Bearings K & F are a rigid surface. Members not listed have forces less than 375# Maximum Top Chord Forces Per Ply (lbs) Chords Tens.Comp. A - B 0 -634 B - C 0 -926 Chords Tens.Comp. C - D 0 -920 D - E 0 -418 Maximum Bot Chord Forces Per Ply (lbs) Chords Tens.Comp. J - I 1116 0 I - H 920 0 Chords Tens.Comp. H - G 912 0 Maximum Web Forces Per Ply (lbs) Webs Tens.Comp. A - J 801 0 K - A 0 -1296 J - B 0 -729 Webs Tens.Comp. D - G 0 -747 G - E 639 0 E - F 0 -553 Loading Criteria (psf) TCLL:40.00 TCDL:10.00 BCLL:0.00 BCDL:5.00 Des Ld:55.00 NCBCLL:10.00 Soffit:2.00 Load Duration: 1.00 Spacing: 24.0 " Wind Criteria Wind Std:NA Speed:NA mph Enclosure: NA Category: NA EXP: NA Kzt: NA Mean Height: NA ft TCDL: NA psf BCDL: NA psf MWFRS Parallel Dist: NA C&C Dist a: NA Loc. from endwall: NA I: NA GCpi: NA Wind Duration: NA Snow Criteria (Pg,Pf in PSF) Pg: NA Ct: NA CAT: NA Pf: NA Ce: NA Lu: NA Cs: NA Snow Duration: NA Building Code: IRC 2021 TPI Std:2014 Rep Fac: Varies by Ld Case FT/RT:12(0)/10(0) Plate Type(s): WAVE Defl/CSI Criteria PP Deflection in loc L/defl L/# VERT(LL):0.069 I 999 360 VERT(CL):0.093 I 999 240 HORZ(LL):0.018 B - - HORZ(TL):0.023 B - - Creep Factor: 2.0 Max TC CSI:0.632 Max BC CSI:0.490 Max Web CSI:0.381 VIEW Ver: 24.01.01A.0510.10 Job Number:TS2207 84 LUMBER Truss Label:F15 Ply: 1 Qty:1 SEQN:120307 SY42 FROM: SC Cust: R 9462 JRef:1YaK94620001 T93 DrwNo:155.25.1734.47637 /BM 06/04/2025 8'8" 3"2'6" (TYP) 1'3"12 3" 4'1"8 4'1"8 5'9"8 1'8" 8'8" 2'10"8 1'8" 1"8 A B C D E FGHIJK 3X4 5X6 4X6 3X4 3X4 3X6 3X6 3X4 4X6 5X6 2X4 **WARNING**READ AND FOLLOW ALL NOTES ON THIS DRAW ING! **IMPORTANT**FURNISH THIS DRAW ING TO ALL CONTRACTORS INCLUDING THE INSTALLERSTrusses require extreme care in fabricating, handling, shipping, installing and bracing. Refer to and follow the latest edition of BCSI (BuildingComponent Safety Information, by TPI and SBCA) for safety practices prior to performing these functions. Installers shall provide temporarybracing per BCSI. Unless noted otherwise, top chord shall have properly attached structural sheathing and bottom chord shall have a properlyattached rigid ceiling. Locations shown for permanent lateral restraint of webs shall have continuous lateral restraint (CLR), installed withdiagonal bracing installed on the CLR per BCSI sections B3, B7, or B10, as applicable. Apply plates to each face of truss and position asshown above and on the Joint Details, unless noted otherwise. Refer to drawings 160A-Z for standard plate positions. Refer to job's GeneralNotes page for additional information.Alpine, a division of ITW Building Components Group Inc. shall not be responsible for any deviation from this drawing, any failure to build thetruss in conformance with ANSI/TPI 1, or for handling, shipping, installation and bracing of trusses. A seal on this drawing or cover pagelisting this drawing, indicates acceptance of professional engineering responsibility solely for the design shown. The suitability and use of thisdrawing for any structure is the responsibility of the Building Designer per ANSI/TPI 1 Sec.2. For more information see these web sites: Alpine: alpineitw.com; TPI: tpinst.org; SBCA: sbcacomponents.com; ICC: iccsafe.org; AWC: awc.org 155 Harlem Ave North Building, 4th Floor Glenview, IL 60025 Lumber Top chord: 4x2 SP #2; Bot chord: 4x2 SP #2; Webs: 4x2 SP #3; Special Loads ------(Lumber Dur.Fac.=1.00 / Plate Dur.Fac.=1.00) TC: From 325 plf at 0.00 to 325 plf at 3.17 TC: From 100 plf at 3.17 to 100 plf at 8.67 BC: From 10 plf at 0.00 to 10 plf at 8.67 Loading Bottom chord checked for 10.00 psf non-concurrent live load. Additional Notes Truss must be installed as shown with top chord up. Maximum Reactions (lbs) Gravity Non-Gravity Loc R+/ R-/ Rh / Rw / U / RL K 1062 /-/-/-/-/- F 604 /-/-/-/-/- K Brg Wid = 2.0 Min Req =1.5 (Truss) F Brg Wid = 3.5 Min Req =1.5 (Truss) Bearings K & F are a rigid surface. Members not listed have forces less than 375# Maximum Top Chord Forces Per Ply (lbs) Chords Tens.Comp. A - B 0 -634 B - C 0 -926 Chords Tens.Comp. C - D 0 -920 D - E 0 -418 Maximum Bot Chord Forces Per Ply (lbs) Chords Tens.Comp. J - I 1116 0 I - H 920 0 Chords Tens.Comp. H - G 912 0 Maximum Web Forces Per Ply (lbs) Webs Tens.Comp. A - J 801 0 K - A 0 -1296 J - B 0 -729 Webs Tens.Comp. D - G 0 -747 G - E 639 0 E - F 0 -553 Loading Criteria (psf) TCLL:40.00 TCDL:10.00 BCLL:0.00 BCDL:5.00 Des Ld:55.00 NCBCLL:10.00 Soffit:2.00 Load Duration: 1.00 Spacing: 24.0 " Wind Criteria Wind Std:NA Speed:NA mph Enclosure: NA Category: NA EXP: NA Kzt: NA Mean Height: NA ft TCDL: NA psf BCDL: NA psf MWFRS Parallel Dist: NA C&C Dist a: NA Loc. from endwall: NA I: NA GCpi: NA Wind Duration: NA Snow Criteria (Pg,Pf in PSF) Pg: NA Ct: NA CAT: NA Pf: NA Ce: NA Lu: NA Cs: NA Snow Duration: NA Building Code: IRC 2021 TPI Std:2014 Rep Fac: Varies by Ld Case FT/RT:12(0)/10(0) Plate Type(s): WAVE Defl/CSI Criteria PP Deflection in loc L/defl L/# VERT(LL):0.069 I 999 360 VERT(CL):0.093 I 999 240 HORZ(LL):0.018 B - - HORZ(TL):0.023 B - - Creep Factor: 2.0 Max TC CSI:0.632 Max BC CSI:0.490 Max Web CSI:0.381 VIEW Ver: 24.01.01A.0510.10 Job Number:TS2207 84 LUMBER Truss Label:F15 Ply: 1 Qty:1 SEQN:120307 SY42 FROM: SC Cust: R 9462 JRef:1YaK94620001 T93 DrwNo:155.25.1734.47637 /BM 06/04/2025 8'8" 3"2'6" (TYP) 1'3"12 3" 4'1"8 4'1"8 5'9"8 1'8" 8'8" 2'10"8 1'8" 1"8 A B C D E FGHIJK 3X4 5X6 4X6 3X4 3X4 3X6 3X6 3X4 4X6 5X6 2X4 $%Lbl:F15?$ 06/04/2025 **WARNING**READ AND FOLLOW ALL NOTES ON THIS DRAW ING! **IMPORTANT**FURNISH THIS DRAW ING TO ALL CONTRACTORS INCLUDING THE INSTALLERSTrusses require extreme care in fabricating, handling, shipping, installing and bracing. Refer to and follow the latest edition of BCSI (BuildingComponent Safety Information, by TPI and SBCA) for safety practices prior to performing these functions. Installers shall provide temporarybracing per BCSI. Unless noted otherwise, top chord shall have properly attached structural sheathing and bottom chord shall have a properlyattached rigid ceiling. Locations shown for permanent lateral restraint of webs shall have continuous lateral restraint (CLR), installed withdiagonal bracing installed on the CLR per BCSI sections B3, B7, or B10, as applicable. Apply plates to each face of truss and position asshown above and on the Joint Details, unless noted otherwise. Refer to drawings 160A-Z for standard plate positions. Refer to job's GeneralNotes page for additional information.Alpine, a division of ITW Building Components Group Inc. shall not be responsible for any deviation from this drawing, any failure to build thetruss in conformance with ANSI/TPI 1, or for handling, shipping, installation and bracing of trusses. A seal on this drawing or cover pagelisting this drawing, indicates acceptance of professional engineering responsibility solely for the design shown. The suitability and use of thisdrawing for any structure is the responsibility of the Building Designer per ANSI/TPI 1 Sec.2. For more information see these web sites: Alpine: alpineitw.com; TPI: tpinst.org; SBCA: sbcacomponents.com; ICC: iccsafe.org; AWC: awc.org 155 Harlem Ave North Building, 4th Floor Glenview, IL 60025 Lumber Top chord: 4x2 SP #2; Bot chord: 4x2 SP #2; Webs: 4x2 SP #3; Special Loads ------(Lumber Dur.Fac.=1.00 / Plate Dur.Fac.=1.00) TC: From 100 plf at 0.00 to 100 plf at 8.92 BC: From 10 plf at 0.00 to 10 plf at 8.92 TC: 700 lb Conc. Load at 3.33 Loading Bottom chord checked for 10.00 psf non-concurrent live load. Additional Notes Truss must be installed as shown with top chord up. Maximum Reactions (lbs) Gravity Non-Gravity Loc R+/ R-/ Rh / Rw / U / RL L 934 /-/-/-/-/- G 747 /-/-/-/-/- L Brg Wid = 3.5 Min Req =1.5 (Truss) G Brg Wid = 3.5 Min Req =1.5 (Truss) Bearings L & G are a rigid surface. Members not listed have forces less than 375# Maximum Top Chord Forces Per Ply (lbs) Chords Tens.Comp. A - B 0 -645 B - C 0 -1434 C - D 0 -1434 Chords Tens.Comp. D - E 0 -1239 E - F 0 -491 Maximum Bot Chord Forces Per Ply (lbs) Chords Tens.Comp. K - J 1278 0 J - I 1387 0 Chords Tens.Comp. I - H 972 0 Maximum Web Forces Per Ply (lbs) Webs Tens.Comp. A - L 0 -925 A - K 1028 0 K - B 0 -1006 B - J 439 0 C - J 12 -495 Webs Tens.Comp. I - E 424 0 E - H 0 -764 H - F 783 0 F - G 0 -724 Loading Criteria (psf) TCLL:40.00 TCDL:10.00 BCLL:0.00 BCDL:5.00 Des Ld:55.00 NCBCLL:10.00 Soffit:2.00 Load Duration: 1.00 Spacing: 24.0 " Wind Criteria Wind Std:NA Speed:NA mph Enclosure: NA Category: NA EXP: NA Kzt: NA Mean Height: NA ft TCDL: NA psf BCDL: NA psf MWFRS Parallel Dist: NA C&C Dist a: NA Loc. from endwall: NA I: NA GCpi: NA Wind Duration: NA Snow Criteria (Pg,Pf in PSF) Pg: NA Ct: NA CAT: NA Pf: NA Ce: NA Lu: NA Cs: NA Snow Duration: NA Building Code: IRC 2021 TPI Std:2014 Rep Fac: Varies by Ld Case FT/RT:12(0)/10(0) Plate Type(s): WAVE Defl/CSI Criteria PP Deflection in loc L/defl L/# VERT(LL):0.064 C 999 360 VERT(CL):0.076 C 999 240 HORZ(LL):0.010 H - - HORZ(TL):0.011 H - - Creep Factor: 2.0 Max TC CSI:0.483 Max BC CSI:0.454 Max Web CSI:0.489 VIEW Ver: 24.01.01A.0510.10 Job Number:TS2207 84 LUMBER Truss Label:F16 Ply: 1 Qty:3 SEQN:120326 SY42 FROM: SC Cust: R 9462 JRef:1YaK94620001 T94 DrwNo:155.25.1734.49100 /BM 06/04/2025 8'11" 3"2'6" (TYP) 7" 9"14 2'0"2 3" 1'8" A B C D E F GHIJKL 4X6 2X4 4X6 3X3 1X3 4X4 3X3 3X3 3X3 4X4 3X6 2X4 **WARNING**READ AND FOLLOW ALL NOTES ON THIS DRAW ING! **IMPORTANT**FURNISH THIS DRAW ING TO ALL CONTRACTORS INCLUDING THE INSTALLERSTrusses require extreme care in fabricating, handling, shipping, installing and bracing. Refer to and follow the latest edition of BCSI (BuildingComponent Safety Information, by TPI and SBCA) for safety practices prior to performing these functions. Installers shall provide temporarybracing per BCSI. Unless noted otherwise, top chord shall have properly attached structural sheathing and bottom chord shall have a properlyattached rigid ceiling. Locations shown for permanent lateral restraint of webs shall have continuous lateral restraint (CLR), installed withdiagonal bracing installed on the CLR per BCSI sections B3, B7, or B10, as applicable. Apply plates to each face of truss and position asshown above and on the Joint Details, unless noted otherwise. Refer to drawings 160A-Z for standard plate positions. Refer to job's GeneralNotes page for additional information.Alpine, a division of ITW Building Components Group Inc. shall not be responsible for any deviation from this drawing, any failure to build thetruss in conformance with ANSI/TPI 1, or for handling, shipping, installation and bracing of trusses. A seal on this drawing or cover pagelisting this drawing, indicates acceptance of professional engineering responsibility solely for the design shown. The suitability and use of thisdrawing for any structure is the responsibility of the Building Designer per ANSI/TPI 1 Sec.2. For more information see these web sites: Alpine: alpineitw.com; TPI: tpinst.org; SBCA: sbcacomponents.com; ICC: iccsafe.org; AWC: awc.org 155 Harlem Ave North Building, 4th Floor Glenview, IL 60025 Lumber Top chord: 4x2 SP #2; Bot chord: 4x2 SP #2; Webs: 4x2 SP #3; Special Loads ------(Lumber Dur.Fac.=1.00 / Plate Dur.Fac.=1.00) TC: From 100 plf at 0.00 to 100 plf at 8.92 BC: From 10 plf at 0.00 to 10 plf at 8.92 TC: 700 lb Conc. Load at 3.33 Loading Bottom chord checked for 10.00 psf non-concurrent live load. Additional Notes Truss must be installed as shown with top chord up. Maximum Reactions (lbs) Gravity Non-Gravity Loc R+/ R-/ Rh / Rw / U / RL L 934 /-/-/-/-/- G 747 /-/-/-/-/- L Brg Wid = 3.5 Min Req =1.5 (Truss) G Brg Wid = 3.5 Min Req =1.5 (Truss) Bearings L & G are a rigid surface. Members not listed have forces less than 375# Maximum Top Chord Forces Per Ply (lbs) Chords Tens.Comp. A - B 0 -645 B - C 0 -1434 C - D 0 -1434 Chords Tens.Comp. D - E 0 -1239 E - F 0 -491 Maximum Bot Chord Forces Per Ply (lbs) Chords Tens.Comp. K - J 1278 0 J - I 1387 0 Chords Tens.Comp. I - H 972 0 Maximum Web Forces Per Ply (lbs) Webs Tens.Comp. A - L 0 -925 A - K 1028 0 K - B 0 -1006 B - J 439 0 C - J 12 -495 Webs Tens.Comp. I - E 424 0 E - H 0 -764 H - F 783 0 F - G 0 -724 Loading Criteria (psf) TCLL:40.00 TCDL:10.00 BCLL:0.00 BCDL:5.00 Des Ld:55.00 NCBCLL:10.00 Soffit:2.00 Load Duration: 1.00 Spacing: 24.0 " Wind Criteria Wind Std:NA Speed:NA mph Enclosure: NA Category: NA EXP: NA Kzt: NA Mean Height: NA ft TCDL: NA psf BCDL: NA psf MWFRS Parallel Dist: NA C&C Dist a: NA Loc. from endwall: NA I: NA GCpi: NA Wind Duration: NA Snow Criteria (Pg,Pf in PSF) Pg: NA Ct: NA CAT: NA Pf: NA Ce: NA Lu: NA Cs: NA Snow Duration: NA Building Code: IRC 2021 TPI Std:2014 Rep Fac: Varies by Ld Case FT/RT:12(0)/10(0) Plate Type(s): WAVE Defl/CSI Criteria PP Deflection in loc L/defl L/# VERT(LL):0.064 C 999 360 VERT(CL):0.076 C 999 240 HORZ(LL):0.010 H - - HORZ(TL):0.011 H - - Creep Factor: 2.0 Max TC CSI:0.483 Max BC CSI:0.454 Max Web CSI:0.489 VIEW Ver: 24.01.01A.0510.10 Job Number:TS2207 84 LUMBER Truss Label:F16 Ply: 1 Qty:3 SEQN:120326 SY42 FROM: SC Cust: R 9462 JRef:1YaK94620001 T94 DrwNo:155.25.1734.49100 /BM 06/04/2025 8'11" 3"2'6" (TYP) 7" 9"14 2'0"2 3" 1'8" A B C D E F GHIJKL 4X6 2X4 4X6 3X3 1X3 4X4 3X3 3X3 3X3 4X4 3X6 2X4 $%Lbl:F16?$ 06/04/2025 **WARNING**READ AND FOLLOW ALL NOTES ON THIS DRAW ING! **IMPORTANT**FURNISH THIS DRAW ING TO ALL CONTRACTORS INCLUDING THE INSTALLERSTrusses require extreme care in fabricating, handling, shipping, installing and bracing. Refer to and follow the latest edition of BCSI (BuildingComponent Safety Information, by TPI and SBCA) for safety practices prior to performing these functions. Installers shall provide temporarybracing per BCSI. Unless noted otherwise, top chord shall have properly attached structural sheathing and bottom chord shall have a properlyattached rigid ceiling. Locations shown for permanent lateral restraint of webs shall have continuous lateral restraint (CLR), installed withdiagonal bracing installed on the CLR per BCSI sections B3, B7, or B10, as applicable. Apply plates to each face of truss and position asshown above and on the Joint Details, unless noted otherwise. Refer to drawings 160A-Z for standard plate positions. Refer to job's GeneralNotes page for additional information.Alpine, a division of ITW Building Components Group Inc. shall not be responsible for any deviation from this drawing, any failure to build thetruss in conformance with ANSI/TPI 1, or for handling, shipping, installation and bracing of trusses. A seal on this drawing or cover pagelisting this drawing, indicates acceptance of professional engineering responsibility solely for the design shown. The suitability and use of thisdrawing for any structure is the responsibility of the Building Designer per ANSI/TPI 1 Sec.2. For more information see these web sites: Alpine: alpineitw.com; TPI: tpinst.org; SBCA: sbcacomponents.com; ICC: iccsafe.org; AWC: awc.org 155 Harlem Ave North Building, 4th Floor Glenview, IL 60025 Lumber Top chord: 4x2 SP #2; Bot chord: 4x2 SP #2; Webs: 4x2 SP #3; Special Loads ------(Lumber Dur.Fac.=1.00 / Plate Dur.Fac.=1.00) TC: From 225 plf at 0.00 to 225 plf at 8.92 BC: From 10 plf at 0.00 to 10 plf at 8.92 TC: 500 lb Conc. Load at 2.00 Loading Bottom chord checked for 10.00 psf non-concurrent live load. Additional Notes Truss must be installed as shown with top chord up. Maximum Reactions (lbs) Gravity Non-Gravity Loc R+/ R-/ Rh / Rw / U / RL L 1444 /-/-/-/-/- F 1152 /-/-/-/-/- L Brg Wid = 3.5 Min Req =1.5 (Truss) F Brg Wid = 3.5 Min Req =1.5 (Truss) Bearings L & F are a rigid surface. Members not listed have forces less than 375# Maximum Top Chord Forces Per Ply (lbs) Chords Tens.Comp. A - B 0 -1041 B - C 0 -1659 Chords Tens.Comp. C - D 0 -1668 D - E 0 -753 Maximum Bot Chord Forces Per Ply (lbs) Chords Tens.Comp. K - J 1442 0 J - I 1442 0 Chords Tens.Comp. I - H 1824 0 H - G 1487 0 Maximum Web Forces Per Ply (lbs) Webs Tens.Comp. A - L 0 -1423 A - K 1589 0 K - B 0 -1204 B - I 416 0 Webs Tens.Comp. D - G 0 -1110 G - E 1112 0 E - F 0 -1228 Loading Criteria (psf) TCLL:40.00 TCDL:10.00 BCLL:0.00 BCDL:5.00 Des Ld:55.00 NCBCLL:10.00 Soffit:2.00 Load Duration: 1.00 Spacing: 24.0 " Wind Criteria Wind Std:NA Speed:NA mph Enclosure: NA Category: NA EXP: NA Kzt: NA Mean Height: NA ft TCDL: NA psf BCDL: NA psf MWFRS Parallel Dist: NA C&C Dist a: NA Loc. from endwall: NA I: NA GCpi: NA Wind Duration: NA Snow Criteria (Pg,Pf in PSF) Pg: NA Ct: NA CAT: NA Pf: NA Ce: NA Lu: NA Cs: NA Snow Duration: NA Building Code: IRC 2021 TPI Std:2014 Rep Fac: Varies by Ld Case FT/RT:12(0)/10(0) Plate Type(s): WAVE Defl/CSI Criteria PP Deflection in loc L/defl L/# VERT(LL):0.062 C 999 360 VERT(CL):0.079 C 999 240 HORZ(LL):0.006 F - - HORZ(TL):0.008 F - - Creep Factor: 2.0 Max TC CSI:0.448 Max BC CSI:0.382 Max Web CSI:0.757 VIEW Ver: 24.01.01A.0510.10 Job Number:TS2207 84 LUMBER Truss Label:F17 Ply: 1 Qty:1 SEQN:120328 SY42 FROM: SC Cust: R 9462 JRef:1YaK94620001 T95 DrwNo:155.25.1734.50577 /BM 06/04/2025 8'11" 3"1'9"1'8"2'6" (TYP) 3" 1'8" 1"8 A B C D E FGHIJKL 6X6 3X4 6X8 4X6 3X6 3X4 3X4 3X4 3X6 5X6 5X6 3X4 **WARNING**READ AND FOLLOW ALL NOTES ON THIS DRAW ING! **IMPORTANT**FURNISH THIS DRAW ING TO ALL CONTRACTORS INCLUDING THE INSTALLERSTrusses require extreme care in fabricating, handling, shipping, installing and bracing. Refer to and follow the latest edition of BCSI (BuildingComponent Safety Information, by TPI and SBCA) for safety practices prior to performing these functions. Installers shall provide temporarybracing per BCSI. Unless noted otherwise, top chord shall have properly attached structural sheathing and bottom chord shall have a properlyattached rigid ceiling. Locations shown for permanent lateral restraint of webs shall have continuous lateral restraint (CLR), installed withdiagonal bracing installed on the CLR per BCSI sections B3, B7, or B10, as applicable. Apply plates to each face of truss and position asshown above and on the Joint Details, unless noted otherwise. Refer to drawings 160A-Z for standard plate positions. Refer to job's GeneralNotes page for additional information.Alpine, a division of ITW Building Components Group Inc. shall not be responsible for any deviation from this drawing, any failure to build thetruss in conformance with ANSI/TPI 1, or for handling, shipping, installation and bracing of trusses. A seal on this drawing or cover pagelisting this drawing, indicates acceptance of professional engineering responsibility solely for the design shown. The suitability and use of thisdrawing for any structure is the responsibility of the Building Designer per ANSI/TPI 1 Sec.2. For more information see these web sites: Alpine: alpineitw.com; TPI: tpinst.org; SBCA: sbcacomponents.com; ICC: iccsafe.org; AWC: awc.org 155 Harlem Ave North Building, 4th Floor Glenview, IL 60025 Lumber Top chord: 4x2 SP #2; Bot chord: 4x2 SP #2; Webs: 4x2 SP #3; Special Loads ------(Lumber Dur.Fac.=1.00 / Plate Dur.Fac.=1.00) TC: From 225 plf at 0.00 to 225 plf at 8.92 BC: From 10 plf at 0.00 to 10 plf at 8.92 TC: 500 lb Conc. Load at 2.00 Loading Bottom chord checked for 10.00 psf non-concurrent live load. Additional Notes Truss must be installed as shown with top chord up. Maximum Reactions (lbs) Gravity Non-Gravity Loc R+/ R-/ Rh / Rw / U / RL L 1444 /-/-/-/-/- F 1152 /-/-/-/-/- L Brg Wid = 3.5 Min Req =1.5 (Truss) F Brg Wid = 3.5 Min Req =1.5 (Truss) Bearings L & F are a rigid surface. Members not listed have forces less than 375# Maximum Top Chord Forces Per Ply (lbs) Chords Tens.Comp. A - B 0 -1041 B - C 0 -1659 Chords Tens.Comp. C - D 0 -1668 D - E 0 -753 Maximum Bot Chord Forces Per Ply (lbs) Chords Tens.Comp. K - J 1442 0 J - I 1442 0 Chords Tens.Comp. I - H 1824 0 H - G 1487 0 Maximum Web Forces Per Ply (lbs) Webs Tens.Comp. A - L 0 -1423 A - K 1589 0 K - B 0 -1204 B - I 416 0 Webs Tens.Comp. D - G 0 -1110 G - E 1112 0 E - F 0 -1228 Loading Criteria (psf) TCLL:40.00 TCDL:10.00 BCLL:0.00 BCDL:5.00 Des Ld:55.00 NCBCLL:10.00 Soffit:2.00 Load Duration: 1.00 Spacing: 24.0 " Wind Criteria Wind Std:NA Speed:NA mph Enclosure: NA Category: NA EXP: NA Kzt: NA Mean Height: NA ft TCDL: NA psf BCDL: NA psf MWFRS Parallel Dist: NA C&C Dist a: NA Loc. from endwall: NA I: NA GCpi: NA Wind Duration: NA Snow Criteria (Pg,Pf in PSF) Pg: NA Ct: NA CAT: NA Pf: NA Ce: NA Lu: NA Cs: NA Snow Duration: NA Building Code: IRC 2021 TPI Std:2014 Rep Fac: Varies by Ld Case FT/RT:12(0)/10(0) Plate Type(s): WAVE Defl/CSI Criteria PP Deflection in loc L/defl L/# VERT(LL):0.062 C 999 360 VERT(CL):0.079 C 999 240 HORZ(LL):0.006 F - - HORZ(TL):0.008 F - - Creep Factor: 2.0 Max TC CSI:0.448 Max BC CSI:0.382 Max Web CSI:0.757 VIEW Ver: 24.01.01A.0510.10 Job Number:TS2207 84 LUMBER Truss Label:F17 Ply: 1 Qty:1 SEQN:120328 SY42 FROM: SC Cust: R 9462 JRef:1YaK94620001 T95 DrwNo:155.25.1734.50577 /BM 06/04/2025 8'11" 3"1'9"1'8"2'6" (TYP) 3" 1'8" 1"8 A B C D E FGHIJKL 6X6 3X4 6X8 4X6 3X6 3X4 3X4 3X4 3X6 5X6 5X6 3X4 $%Lbl:F17?$ 06/04/2025 **WARNING**READ AND FOLLOW ALL NOTES ON THIS DRAW ING! **IMPORTANT**FURNISH THIS DRAW ING TO ALL CONTRACTORS INCLUDING THE INSTALLERSTrusses require extreme care in fabricating, handling, shipping, installing and bracing. Refer to and follow the latest edition of BCSI (BuildingComponent Safety Information, by TPI and SBCA) for safety practices prior to performing these functions. Installers shall provide temporarybracing per BCSI. Unless noted otherwise, top chord shall have properly attached structural sheathing and bottom chord shall have a properlyattached rigid ceiling. Locations shown for permanent lateral restraint of webs shall have continuous lateral restraint (CLR), installed withdiagonal bracing installed on the CLR per BCSI sections B3, B7, or B10, as applicable. Apply plates to each face of truss and position asshown above and on the Joint Details, unless noted otherwise. Refer to drawings 160A-Z for standard plate positions. Refer to job's GeneralNotes page for additional information.Alpine, a division of ITW Building Components Group Inc. shall not be responsible for any deviation from this drawing, any failure to build thetruss in conformance with ANSI/TPI 1, or for handling, shipping, installation and bracing of trusses. A seal on this drawing or cover pagelisting this drawing, indicates acceptance of professional engineering responsibility solely for the design shown. The suitability and use of thisdrawing for any structure is the responsibility of the Building Designer per ANSI/TPI 1 Sec.2. For more information see these web sites: Alpine: alpineitw.com; TPI: tpinst.org; SBCA: sbcacomponents.com; ICC: iccsafe.org; AWC: awc.org 155 Harlem Ave North Building, 4th Floor Glenview, IL 60025 Lumber Top chord: 4x2 SP #2; Bot chord: 4x2 SP #2; Webs: 4x2 SP #3; Loading Bottom chord checked for 10.00 psf non-concurrent live load. Additional Notes Truss must be installed as shown with top chord up. Maximum Reactions (lbs) Gravity Non-Gravity Loc R+/ R-/ Rh / Rw / U / RL A 474 /-/-/-/-/- H 486 /-/-/-/-/- A Brg Wid = 3.5 Min Req =1.5 (Truss) H Brg Wid = 3.5 Min Req =1.5 (Truss) Bearings A & H are a rigid surface. Members not listed have forces less than 375# Maximum Top Chord Forces Per Ply (lbs) Chords Tens.Comp. D - E 0 -586 Chords Tens.Comp. E - F 0 -587 Maximum Bot Chord Forces Per Ply (lbs) Chords Tens.Comp. L - K 584 0 K - J 587 0 Chords Tens.Comp. J - I 584 0 Maximum Web Forces Per Ply (lbs) Webs Tens.Comp. B - L 483 0 L - D 0 -414 F - I 0 -477 Webs Tens.Comp. I - G 454 0 G - H 0 -459 Loading Criteria (psf) TCLL:40.00 TCDL:10.00 BCLL:0.00 BCDL:5.00 Des Ld:55.00 NCBCLL:10.00 Soffit:2.00 Load Duration: 1.00 Spacing: 24.0 " Wind Criteria Wind Std:NA Speed:NA mph Enclosure: NA Category: NA EXP: NA Kzt: NA Mean Height: NA ft TCDL: NA psf BCDL: NA psf MWFRS Parallel Dist: NA C&C Dist a: NA Loc. from endwall: NA I: NA GCpi: NA Wind Duration: NA Snow Criteria (Pg,Pf in PSF) Pg: NA Ct: NA CAT: NA Pf: NA Ce: NA Lu: NA Cs: NA Snow Duration: NA Building Code: IRC 2021 TPI Std:2014 Rep Fac: Yes FT/RT:12(0)/10(0) Plate Type(s): WAVE Defl/CSI Criteria PP Deflection in loc L/defl L/# VERT(LL):0.053 E 999 360 VERT(CL):0.083 E 999 240 HORZ(LL):-0.015 M - - HORZ(TL):0.023 M - - Creep Factor: 2.0 Max TC CSI:0.578 Max BC CSI:0.417 Max Web CSI:0.230 VIEW Ver: 24.01.01A.0510.10 Job Number:TS2207 84 LUMBER Truss Label:F18 Ply: 1 Qty:1 SEQN:120313 SY42 FROM: SC Cust: R 9462 JRef:1YaK94620001 T96 DrwNo:155.25.1734.51927 /BM 06/04/2025 8'9" 5"2'6" (TYP) 1'3"12 3" 4'3"8 4'3"8 5'10"8 1'7" 8'9" 2'10"8 1'5" 3" 1'8" A B C D E F G HIJKLM1X3 3X6 3X3 3X3 3X3 3X3 1X3 1X3 3X3 3X3 3X4 2X4 **WARNING**READ AND FOLLOW ALL NOTES ON THIS DRAW ING! **IMPORTANT**FURNISH THIS DRAW ING TO ALL CONTRACTORS INCLUDING THE INSTALLERSTrusses require extreme care in fabricating, handling, shipping, installing and bracing. Refer to and follow the latest edition of BCSI (BuildingComponent Safety Information, by TPI and SBCA) for safety practices prior to performing these functions. Installers shall provide temporarybracing per BCSI. Unless noted otherwise, top chord shall have properly attached structural sheathing and bottom chord shall have a properlyattached rigid ceiling. Locations shown for permanent lateral restraint of webs shall have continuous lateral restraint (CLR), installed withdiagonal bracing installed on the CLR per BCSI sections B3, B7, or B10, as applicable. Apply plates to each face of truss and position asshown above and on the Joint Details, unless noted otherwise. Refer to drawings 160A-Z for standard plate positions. Refer to job's GeneralNotes page for additional information.Alpine, a division of ITW Building Components Group Inc. shall not be responsible for any deviation from this drawing, any failure to build thetruss in conformance with ANSI/TPI 1, or for handling, shipping, installation and bracing of trusses. A seal on this drawing or cover pagelisting this drawing, indicates acceptance of professional engineering responsibility solely for the design shown. The suitability and use of thisdrawing for any structure is the responsibility of the Building Designer per ANSI/TPI 1 Sec.2. For more information see these web sites: Alpine: alpineitw.com; TPI: tpinst.org; SBCA: sbcacomponents.com; ICC: iccsafe.org; AWC: awc.org 155 Harlem Ave North Building, 4th Floor Glenview, IL 60025 Lumber Top chord: 4x2 SP #2; Bot chord: 4x2 SP #2; Webs: 4x2 SP #3; Loading Bottom chord checked for 10.00 psf non-concurrent live load. Additional Notes Truss must be installed as shown with top chord up. Maximum Reactions (lbs) Gravity Non-Gravity Loc R+/ R-/ Rh / Rw / U / RL A 474 /-/-/-/-/- H 486 /-/-/-/-/- A Brg Wid = 3.5 Min Req =1.5 (Truss) H Brg Wid = 3.5 Min Req =1.5 (Truss) Bearings A & H are a rigid surface. Members not listed have forces less than 375# Maximum Top Chord Forces Per Ply (lbs) Chords Tens.Comp. D - E 0 -586 Chords Tens.Comp. E - F 0 -587 Maximum Bot Chord Forces Per Ply (lbs) Chords Tens.Comp. L - K 584 0 K - J 587 0 Chords Tens.Comp. J - I 584 0 Maximum Web Forces Per Ply (lbs) Webs Tens.Comp. B - L 483 0 L - D 0 -414 F - I 0 -477 Webs Tens.Comp. I - G 454 0 G - H 0 -459 Loading Criteria (psf) TCLL:40.00 TCDL:10.00 BCLL:0.00 BCDL:5.00 Des Ld:55.00 NCBCLL:10.00 Soffit:2.00 Load Duration: 1.00 Spacing: 24.0 " Wind Criteria Wind Std:NA Speed:NA mph Enclosure: NA Category: NA EXP: NA Kzt: NA Mean Height: NA ft TCDL: NA psf BCDL: NA psf MWFRS Parallel Dist: NA C&C Dist a: NA Loc. from endwall: NA I: NA GCpi: NA Wind Duration: NA Snow Criteria (Pg,Pf in PSF) Pg: NA Ct: NA CAT: NA Pf: NA Ce: NA Lu: NA Cs: NA Snow Duration: NA Building Code: IRC 2021 TPI Std:2014 Rep Fac: Yes FT/RT:12(0)/10(0) Plate Type(s): WAVE Defl/CSI Criteria PP Deflection in loc L/defl L/# VERT(LL):0.053 E 999 360 VERT(CL):0.083 E 999 240 HORZ(LL):-0.015 M - - HORZ(TL):0.023 M - - Creep Factor: 2.0 Max TC CSI:0.578 Max BC CSI:0.417 Max Web CSI:0.230 VIEW Ver: 24.01.01A.0510.10 Job Number:TS2207 84 LUMBER Truss Label:F18 Ply: 1 Qty:1 SEQN:120313 SY42 FROM: SC Cust: R 9462 JRef:1YaK94620001 T96 DrwNo:155.25.1734.51927 /BM 06/04/2025 8'9" 5"2'6" (TYP) 1'3"12 3" 4'3"8 4'3"8 5'10"8 1'7" 8'9" 2'10"8 1'5" 3" 1'8" A B C D E F G HIJKLM1X3 3X6 3X3 3X3 3X3 3X3 1X3 1X3 3X3 3X3 3X4 2X4 $%Lbl:f18?$ 06/04/2025 **WARNING**READ AND FOLLOW ALL NOTES ON THIS DRAW ING! **IMPORTANT**FURNISH THIS DRAW ING TO ALL CONTRACTORS INCLUDING THE INSTALLERSTrusses require extreme care in fabricating, handling, shipping, installing and bracing. Refer to and follow the latest edition of BCSI (BuildingComponent Safety Information, by TPI and SBCA) for safety practices prior to performing these functions. Installers shall provide temporarybracing per BCSI. Unless noted otherwise, top chord shall have properly attached structural sheathing and bottom chord shall have a properlyattached rigid ceiling. Locations shown for permanent lateral restraint of webs shall have continuous lateral restraint (CLR), installed withdiagonal bracing installed on the CLR per BCSI sections B3, B7, or B10, as applicable. Apply plates to each face of truss and position asshown above and on the Joint Details, unless noted otherwise. Refer to drawings 160A-Z for standard plate positions. Refer to job's GeneralNotes page for additional information.Alpine, a division of ITW Building Components Group Inc. shall not be responsible for any deviation from this drawing, any failure to build thetruss in conformance with ANSI/TPI 1, or for handling, shipping, installation and bracing of trusses. A seal on this drawing or cover pagelisting this drawing, indicates acceptance of professional engineering responsibility solely for the design shown. The suitability and use of thisdrawing for any structure is the responsibility of the Building Designer per ANSI/TPI 1 Sec.2. For more information see these web sites: Alpine: alpineitw.com; TPI: tpinst.org; SBCA: sbcacomponents.com; ICC: iccsafe.org; AWC: awc.org 155 Harlem Ave North Building, 4th Floor Glenview, IL 60025 Lumber Top chord: 4x2 SP #2; Bot chord: 4x2 SP #2; Webs: 4x2 SP #3; Special Loads ------(Lumber Dur.Fac.=1.00 / Plate Dur.Fac.=1.00) TC: From 100 plf at 0.00 to 100 plf at 23.21 BC: From 10 plf at 0.00 to 10 plf at 23.21 TC: 946 lb Conc. Load at 0.00 TC: 650 lb Conc. Load at 12.88,18.29 Loading Bottom chord checked for 10.00 psf non-concurrent live load. Additional Notes + 2x6 continuous strongback. See detail STRBRIBR1014 for bracing and bridging recommendations. Negative reaction(s) of -202# MAX. from a non-wind load case requires uplift connection. See Maximum Reactions. Truss must be installed as shown with top chord up. Maximum Reactions (lbs) Gravity Non-Gravity Loc R+/ R-/ Rh / Rw / U / RL AB 1920 /-/-/-/-/- R 2834 /-/-/-/-/- N 270 /-202 /-/-/-/- AB Brg Wid = 3.5 Min Req =1.5 (Truss) R Brg Wid = 3.5 Min Req =1.5 (Truss) N Brg Wid = 3.5 Min Req =1.5 (Truss) Bearings AB, R, & N are a rigid surface. Members not listed have forces less than 375# Maximum Top Chord Forces Per Ply (lbs) Chords Tens.Comp. B - C 42 -516 C - D 0 -1556 D - E 0 -2148 E - F 0 -2148 F - G 0 -2297 Chords Tens.Comp. G - H 0 -1978 H - I 0 -1694 I - J 473 0 J - K 865 0 K - L 649 -75 Maximum Bot Chord Forces Per Ply (lbs) Chords Tens.Comp. AA- Z 1131 0 Z - Y 1954 0 Y - X 2333 0 X - W 2333 0 W -V 2237 0 V - U 1784 0 Chords Tens.Comp. U - T 641 0 T - S 641 0 S - R 0 -1655 R - Q 0 -1655 Q - P 0 -839 P - O 203 -393 Maximum Web Forces Per Ply (lbs) Webs Tens.Comp. A -AB 28 -848 AB- B 0 -996 B -AA 954 0 AA- C 0 -996 C - Z 675 0 Z - D 0 -632 G - V 0 -569 V - H 522 0 H - U 0 -1112 Webs Tens.Comp. U - I 1556 0 I - S 0 -1769 S - J 1777 0 J - R 0 -2680 J - Q 1353 0 Q - K 0 -1145 K - P 488 0 P - L 0 -503 Loading Criteria (psf) TCLL:40.00 TCDL:10.00 BCLL:0.00 BCDL:5.00 Des Ld:55.00 NCBCLL:10.00 Soffit:2.00 Load Duration: 1.00 Spacing: 24.0 " Wind Criteria Wind Std:NA Speed:NA mph Enclosure: NA Category: NA EXP: NA Kzt: NA Mean Height: NA ft TCDL: NA psf BCDL: NA psf MWFRS Parallel Dist: NA C&C Dist a: NA Loc. from endwall: NA I: NA GCpi: NA Wind Duration: NA Snow Criteria (Pg,Pf in PSF) Pg: NA Ct: NA CAT: NA Pf: NA Ce: NA Lu: NA Cs: NA Snow Duration: NA Building Code: IRC 2021 TPI Std:2014 Rep Fac: Varies by Ld Case FT/RT:12(0)/10(0) Plate Type(s): WAVE Defl/CSI Criteria PP Deflection in loc L/defl L/# VERT(LL):0.200 W 996 360 VERT(CL):0.246 W 809 240 HORZ(LL):0.037 A - - HORZ(TL):0.044 A - - Creep Factor: 2.0 Max TC CSI:0.744 Max BC CSI:0.724 Max Web CSI:0.846 VIEW Ver: 24.01.01A.0510.10 Job Number:TS2207 84 LUMBER Truss Label:F19 Ply: 1 Qty:1 SEQN:120315 SY42 FROM: SC Cust: R 9462 JRef:1YaK94620001 T97 DrwNo:155.25.1734.54947 /BM 06/04/2025 3"8 3"8 5"16'8"4 6'2"12 6" 2'6" (TYP) 2'6"12 2'6"12 2'2"4 1'6"8 3"2'1"4 3" 23'4" 17'1"4 17'1"4 23'4" 6'2"12 1'8" + A B C D E F G H I J K L M NOPQRSTUVWXYZAAABAC 1X3 1X3 3X3 1X33X3 4X4 4X4 3X4 3X4 3X3 3X3 W=3X43X4 1X3 3X3 3X3 3X3 3X3 5X6W=3X4 5X6 5X6 5X12 3X3 4X6 3X3 3X3 3X3 3X3 3X4 2X4 **WARNING**READ AND FOLLOW ALL NOTES ON THIS DRAW ING! **IMPORTANT**FURNISH THIS DRAW ING TO ALL CONTRACTORS INCLUDING THE INSTALLERSTrusses require extreme care in fabricating, handling, shipping, installing and bracing. Refer to and follow the latest edition of BCSI (BuildingComponent Safety Information, by TPI and SBCA) for safety practices prior to performing these functions. Installers shall provide temporarybracing per BCSI. Unless noted otherwise, top chord shall have properly attached structural sheathing and bottom chord shall have a properlyattached rigid ceiling. Locations shown for permanent lateral restraint of webs shall have continuous lateral restraint (CLR), installed withdiagonal bracing installed on the CLR per BCSI sections B3, B7, or B10, as applicable. Apply plates to each face of truss and position asshown above and on the Joint Details, unless noted otherwise. Refer to drawings 160A-Z for standard plate positions. Refer to job's GeneralNotes page for additional information.Alpine, a division of ITW Building Components Group Inc. shall not be responsible for any deviation from this drawing, any failure to build thetruss in conformance with ANSI/TPI 1, or for handling, shipping, installation and bracing of trusses. A seal on this drawing or cover pagelisting this drawing, indicates acceptance of professional engineering responsibility solely for the design shown. The suitability and use of thisdrawing for any structure is the responsibility of the Building Designer per ANSI/TPI 1 Sec.2. For more information see these web sites: Alpine: alpineitw.com; TPI: tpinst.org; SBCA: sbcacomponents.com; ICC: iccsafe.org; AWC: awc.org 155 Harlem Ave North Building, 4th Floor Glenview, IL 60025 Lumber Top chord: 4x2 SP #2; Bot chord: 4x2 SP #2; Webs: 4x2 SP #3; Special Loads ------(Lumber Dur.Fac.=1.00 / Plate Dur.Fac.=1.00) TC: From 100 plf at 0.00 to 100 plf at 23.21 BC: From 10 plf at 0.00 to 10 plf at 23.21 TC: 946 lb Conc. Load at 0.00 TC: 650 lb Conc. Load at 12.88,18.29 Loading Bottom chord checked for 10.00 psf non-concurrent live load. Additional Notes + 2x6 continuous strongback. See detail STRBRIBR1014 for bracing and bridging recommendations. Negative reaction(s) of -202# MAX. from a non-wind load case requires uplift connection. See Maximum Reactions. Truss must be installed as shown with top chord up. Maximum Reactions (lbs) Gravity Non-Gravity Loc R+/ R-/ Rh / Rw / U / RL AB 1920 /-/-/-/-/- R 2834 /-/-/-/-/- N 270 /-202 /-/-/-/- AB Brg Wid = 3.5 Min Req =1.5 (Truss) R Brg Wid = 3.5 Min Req =1.5 (Truss) N Brg Wid = 3.5 Min Req =1.5 (Truss) Bearings AB, R, & N are a rigid surface. Members not listed have forces less than 375# Maximum Top Chord Forces Per Ply (lbs) Chords Tens.Comp. B - C 42 -516 C - D 0 -1556 D - E 0 -2148 E - F 0 -2148 F - G 0 -2297 Chords Tens.Comp. G - H 0 -1978 H - I 0 -1694 I - J 473 0 J - K 865 0 K - L 649 -75 Maximum Bot Chord Forces Per Ply (lbs) Chords Tens.Comp. AA- Z 1131 0 Z - Y 1954 0 Y - X 2333 0 X - W 2333 0 W -V 2237 0 V - U 1784 0 Chords Tens.Comp. U - T 641 0 T - S 641 0 S - R 0 -1655 R - Q 0 -1655 Q - P 0 -839 P - O 203 -393 Maximum Web Forces Per Ply (lbs) Webs Tens.Comp. A -AB 28 -848 AB- B 0 -996 B -AA 954 0 AA- C 0 -996 C - Z 675 0 Z - D 0 -632 G - V 0 -569 V - H 522 0 H - U 0 -1112 Webs Tens.Comp. U - I 1556 0 I - S 0 -1769 S - J 1777 0 J - R 0 -2680 J - Q 1353 0 Q - K 0 -1145 K - P 488 0 P - L 0 -503 Loading Criteria (psf) TCLL:40.00 TCDL:10.00 BCLL:0.00 BCDL:5.00 Des Ld:55.00 NCBCLL:10.00 Soffit:2.00 Load Duration: 1.00 Spacing: 24.0 " Wind Criteria Wind Std:NA Speed:NA mph Enclosure: NA Category: NA EXP: NA Kzt: NA Mean Height: NA ft TCDL: NA psf BCDL: NA psf MWFRS Parallel Dist: NA C&C Dist a: NA Loc. from endwall: NA I: NA GCpi: NA Wind Duration: NA Snow Criteria (Pg,Pf in PSF) Pg: NA Ct: NA CAT: NA Pf: NA Ce: NA Lu: NA Cs: NA Snow Duration: NA Building Code: IRC 2021 TPI Std:2014 Rep Fac: Varies by Ld Case FT/RT:12(0)/10(0) Plate Type(s): WAVE Defl/CSI Criteria PP Deflection in loc L/defl L/# VERT(LL):0.200 W 996 360 VERT(CL):0.246 W 809 240 HORZ(LL):0.037 A - - HORZ(TL):0.044 A - - Creep Factor: 2.0 Max TC CSI:0.744 Max BC CSI:0.724 Max Web CSI:0.846 VIEW Ver: 24.01.01A.0510.10 Job Number:TS2207 84 LUMBER Truss Label:F19 Ply: 1 Qty:1 SEQN:120315 SY42 FROM: SC Cust: R 9462 JRef:1YaK94620001 T97 DrwNo:155.25.1734.54947 /BM 06/04/2025 3"8 3"8 5"16'8"4 6'2"12 6" 2'6" (TYP) 2'6"12 2'6"12 2'2"4 1'6"8 3"2'1"4 3" 23'4" 17'1"4 17'1"4 23'4" 6'2"12 1'8" + A B C D E F G H I J K L M NOPQRSTUVWXYZAAABAC 1X3 1X3 3X3 1X33X3 4X4 4X4 3X4 3X4 3X3 3X3 W=3X43X4 1X3 3X3 3X3 3X3 3X3 5X6W=3X4 5X6 5X6 5X12 3X3 4X6 3X3 3X3 3X3 3X3 3X4 2X4 $%Lbl:f19?$ 06/04/2025 **WARNING**READ AND FOLLOW ALL NOTES ON THIS DRAW ING! **IMPORTANT**FURNISH THIS DRAW ING TO ALL CONTRACTORS INCLUDING THE INSTALLERSTrusses require extreme care in fabricating, handling, shipping, installing and bracing. Refer to and follow the latest edition of BCSI (BuildingComponent Safety Information, by TPI and SBCA) for safety practices prior to performing these functions. Installers shall provide temporarybracing per BCSI. Unless noted otherwise, top chord shall have properly attached structural sheathing and bottom chord shall have a properlyattached rigid ceiling. Locations shown for permanent lateral restraint of webs shall have continuous lateral restraint (CLR), installed withdiagonal bracing installed on the CLR per BCSI sections B3, B7, or B10, as applicable. Apply plates to each face of truss and position asshown above and on the Joint Details, unless noted otherwise. Refer to drawings 160A-Z for standard plate positions. Refer to job's GeneralNotes page for additional information.Alpine, a division of ITW Building Components Group Inc. shall not be responsible for any deviation from this drawing, any failure to build thetruss in conformance with ANSI/TPI 1, or for handling, shipping, installation and bracing of trusses. A seal on this drawing or cover pagelisting this drawing, indicates acceptance of professional engineering responsibility solely for the design shown. The suitability and use of thisdrawing for any structure is the responsibility of the Building Designer per ANSI/TPI 1 Sec.2. For more information see these web sites: Alpine: alpineitw.com; TPI: tpinst.org; SBCA: sbcacomponents.com; ICC: iccsafe.org; AWC: awc.org 155 Harlem Ave North Building, 4th Floor Glenview, IL 60025 Lumber Top chord: 4x2 SP #2; Bot chord: 4x2 SP #1; B2 4x2 SP #2; Webs: 4x2 SP #3; Loading Bottom chord checked for 10.00 psf non-concurrent live load. Deflection Max JT VERT DEFL: LL: 0.30" DL: 0.20". See detail DEFLCAMB1014 for camber recommendations. Additional Notes + 2x6 continuous strongback. See detail STRBRIBR1014 for bracing and bridging recommendations. This truss spaced @ 16.0" oc supports additional concentrated load at left end from 10.00' stud wall (11.00 PSF) supporting 10-0-0 roof spans with 1-0-0 overhang. Roof load: 40.00 psf LL and 20.00 psf DL. Truss must be installed as shown with top chord up. Maximum Reactions (lbs) Gravity Non-Gravity Loc R+/ R-/ Rh / Rw / U / RL AB 1499 /-/-/-/-/- N 839 /-/-/-/-/- AB Brg Wid = 3.5 Min Req =1.5 (Truss) N Brg Wid = 3.5 Min Req =1.5 (Truss) Bearings AB & N are a rigid surface. Members not listed have forces less than 375# Maximum Top Chord Forces Per Ply (lbs) Chords Tens.Comp. B - C 0 -604 C - D 0 -1655 D - E 0 -2395 E - F 0 -2855 F - G 0 -2855 Chords Tens.Comp. G - H 0 -2995 H - I 0 -2864 I - J 0 -2414 J - K 0 -1683 K - L 0 -637 Maximum Bot Chord Forces Per Ply (lbs) Chords Tens.Comp. AA- Z 1199 0 Z - Y 2093 0 Y - X 2701 0 X - W 2701 0 W -V 2995 0 V - U 2995 0 Chords Tens.Comp. U - T 2995 0 T - S 2715 0 S - R 2715 0 R - Q 2715 0 Q - P 2114 0 P - O 1237 0 Maximum Web Forces Per Ply (lbs) Webs Tens.Comp. A -AB 31 -552 AB- B 0 -872 B -AA 915 0 AA- C 0 -949 C - Z 734 0 Z - D 0 -703 D - Y 487 0 Y - E 0 -479 W -G 75 -448 Webs Tens.Comp. H - T 104 -419 I - Q 0 -465 Q - J 476 0 J - P 0 -683 P - K 709 0 K - O 0 -954 O - L 983 0 L - M 0 -818 M - N 0 -824 Loading Criteria (psf) TCLL:40.00 TCDL:10.00 BCLL:0.00 BCDL:5.00 Des Ld:55.00 NCBCLL:10.00 Soffit:2.00 Load Duration: 1.00 Spacing: 16.0 " Wind Criteria Wind Std:NA Speed:NA mph Enclosure: NA Category: NA EXP: NA Kzt: NA Mean Height: NA ft TCDL: NA psf BCDL: NA psf MWFRS Parallel Dist: NA C&C Dist a: NA Loc. from endwall: NA I: NA GCpi: NA Wind Duration: NA Snow Criteria (Pg,Pf in PSF) Pg: NA Ct: NA CAT: NA Pf: NA Ce: NA Lu: NA Cs: NA Snow Duration: NA Building Code: IRC 2021 TPI Std:2014 Rep Fac: Yes FT/RT:12(0)/10(0) Plate Type(s): WAVE, HS Defl/CSI Criteria PP Deflection in loc L/defl L/# VERT(LL):0.302 U 900 360 VERT(CL):0.416 U 653 240 HORZ(LL):0.049 A - - HORZ(TL):0.069 A - - Creep Factor: 2.0 Max TC CSI:0.551 Max BC CSI:0.795 Max Web CSI:0.468 VIEW Ver: 24.01.01A.0510.10 Job Number:TS2207 84 LUMBER Truss Label:F20 Ply: 1 Qty:13 SEQN:120317 SY42 FROM: SC Cust: R 9462 JRef:1YaK94620001 T98 DrwNo:155.25.1734.58470 /BM 06/04/2025 B2 3"8 3"8 5"22'11" 6" 2'6" (TYP) 2'6"12 2'6"12 2'6"12 2'6"12 3" 23'4" 10'10"8 10'10"8 12'10" 1'11"8 23'4" 10'6" 1'8" ++ A B C D E F G H I J K LM NOPQRSTUVWXYZAAABAC 1X3 1X3 3X3 1X33X3 4X4 4X4 4X4 4X4 3X3 3X3 3X4 1X3 W=3X4 3X3 3X3 1X3 1X3 3X3 3X3 3X4 1X3W=H03103X3 3X3 4X4 4X4 4X4 4X4 2X4 1X3 **WARNING**READ AND FOLLOW ALL NOTES ON THIS DRAW ING! **IMPORTANT**FURNISH THIS DRAW ING TO ALL CONTRACTORS INCLUDING THE INSTALLERSTrusses require extreme care in fabricating, handling, shipping, installing and bracing. Refer to and follow the latest edition of BCSI (BuildingComponent Safety Information, by TPI and SBCA) for safety practices prior to performing these functions. Installers shall provide temporarybracing per BCSI. Unless noted otherwise, top chord shall have properly attached structural sheathing and bottom chord shall have a properlyattached rigid ceiling. Locations shown for permanent lateral restraint of webs shall have continuous lateral restraint (CLR), installed withdiagonal bracing installed on the CLR per BCSI sections B3, B7, or B10, as applicable. Apply plates to each face of truss and position asshown above and on the Joint Details, unless noted otherwise. Refer to drawings 160A-Z for standard plate positions. Refer to job's GeneralNotes page for additional information.Alpine, a division of ITW Building Components Group Inc. shall not be responsible for any deviation from this drawing, any failure to build thetruss in conformance with ANSI/TPI 1, or for handling, shipping, installation and bracing of trusses. A seal on this drawing or cover pagelisting this drawing, indicates acceptance of professional engineering responsibility solely for the design shown. The suitability and use of thisdrawing for any structure is the responsibility of the Building Designer per ANSI/TPI 1 Sec.2. For more information see these web sites: Alpine: alpineitw.com; TPI: tpinst.org; SBCA: sbcacomponents.com; ICC: iccsafe.org; AWC: awc.org 155 Harlem Ave North Building, 4th Floor Glenview, IL 60025 Lumber Top chord: 4x2 SP #2; Bot chord: 4x2 SP #1; B2 4x2 SP #2; Webs: 4x2 SP #3; Loading Bottom chord checked for 10.00 psf non-concurrent live load. Deflection Max JT VERT DEFL: LL: 0.30" DL: 0.20". See detail DEFLCAMB1014 for camber recommendations. Additional Notes + 2x6 continuous strongback. See detail STRBRIBR1014 for bracing and bridging recommendations. This truss spaced @ 16.0" oc supports additional concentrated load at left end from 10.00' stud wall (11.00 PSF) supporting 10-0-0 roof spans with 1-0-0 overhang. Roof load: 40.00 psf LL and 20.00 psf DL. Truss must be installed as shown with top chord up. Maximum Reactions (lbs) Gravity Non-Gravity Loc R+/ R-/ Rh / Rw / U / RL AB 1499 /-/-/-/-/- N 839 /-/-/-/-/- AB Brg Wid = 3.5 Min Req =1.5 (Truss) N Brg Wid = 3.5 Min Req =1.5 (Truss) Bearings AB & N are a rigid surface. Members not listed have forces less than 375# Maximum Top Chord Forces Per Ply (lbs) Chords Tens.Comp. B - C 0 -604 C - D 0 -1655 D - E 0 -2395 E - F 0 -2855 F - G 0 -2855 Chords Tens.Comp. G - H 0 -2995 H - I 0 -2864 I - J 0 -2414 J - K 0 -1683 K - L 0 -637 Maximum Bot Chord Forces Per Ply (lbs) Chords Tens.Comp. AA- Z 1199 0 Z - Y 2093 0 Y - X 2701 0 X - W 2701 0 W -V 2995 0 V - U 2995 0 Chords Tens.Comp. U - T 2995 0 T - S 2715 0 S - R 2715 0 R - Q 2715 0 Q - P 2114 0 P - O 1237 0 Maximum Web Forces Per Ply (lbs) Webs Tens.Comp. A -AB 31 -552 AB- B 0 -872 B -AA 915 0 AA- C 0 -949 C - Z 734 0 Z - D 0 -703 D - Y 487 0 Y - E 0 -479 W -G 75 -448 Webs Tens.Comp. H - T 104 -419 I - Q 0 -465 Q - J 476 0 J - P 0 -683 P - K 709 0 K - O 0 -954 O - L 983 0 L - M 0 -818 M - N 0 -824 Loading Criteria (psf) TCLL:40.00 TCDL:10.00 BCLL:0.00 BCDL:5.00 Des Ld:55.00 NCBCLL:10.00 Soffit:2.00 Load Duration: 1.00 Spacing: 16.0 " Wind Criteria Wind Std:NA Speed:NA mph Enclosure: NA Category: NA EXP: NA Kzt: NA Mean Height: NA ft TCDL: NA psf BCDL: NA psf MWFRS Parallel Dist: NA C&C Dist a: NA Loc. from endwall: NA I: NA GCpi: NA Wind Duration: NA Snow Criteria (Pg,Pf in PSF) Pg: NA Ct: NA CAT: NA Pf: NA Ce: NA Lu: NA Cs: NA Snow Duration: NA Building Code: IRC 2021 TPI Std:2014 Rep Fac: Yes FT/RT:12(0)/10(0) Plate Type(s): WAVE, HS Defl/CSI Criteria PP Deflection in loc L/defl L/# VERT(LL):0.302 U 900 360 VERT(CL):0.416 U 653 240 HORZ(LL):0.049 A - - HORZ(TL):0.069 A - - Creep Factor: 2.0 Max TC CSI:0.551 Max BC CSI:0.795 Max Web CSI:0.468 VIEW Ver: 24.01.01A.0510.10 Job Number:TS2207 84 LUMBER Truss Label:F20 Ply: 1 Qty:13 SEQN:120317 SY42 FROM: SC Cust: R 9462 JRef:1YaK94620001 T98 DrwNo:155.25.1734.58470 /BM 06/04/2025 B2 3"8 3"8 5"22'11" 6" 2'6" (TYP) 2'6"12 2'6"12 2'6"12 2'6"12 3" 23'4" 10'10"8 10'10"8 12'10" 1'11"8 23'4" 10'6" 1'8" ++ A B C D E F G H I J K LM NOPQRSTUVWXYZAAABAC 1X3 1X3 3X3 1X33X3 4X4 4X4 4X4 4X4 3X3 3X3 3X4 1X3 W=3X4 3X3 3X3 1X3 1X3 3X3 3X3 3X4 1X3W=H03103X3 3X3 4X4 4X4 4X4 4X4 2X4 1X3 $%Lbl:F20?$ 06/04/2025 **WARNING**READ AND FOLLOW ALL NOTES ON THIS DRAW ING! **IMPORTANT**FURNISH THIS DRAW ING TO ALL CONTRACTORS INCLUDING THE INSTALLERSTrusses require extreme care in fabricating, handling, shipping, installing and bracing. Refer to and follow the latest edition of BCSI (BuildingComponent Safety Information, by TPI and SBCA) for safety practices prior to performing these functions. Installers shall provide temporarybracing per BCSI. Unless noted otherwise, top chord shall have properly attached structural sheathing and bottom chord shall have a properlyattached rigid ceiling. Locations shown for permanent lateral restraint of webs shall have continuous lateral restraint (CLR), installed withdiagonal bracing installed on the CLR per BCSI sections B3, B7, or B10, as applicable. Apply plates to each face of truss and position asshown above and on the Joint Details, unless noted otherwise. Refer to drawings 160A-Z for standard plate positions. Refer to job's GeneralNotes page for additional information.Alpine, a division of ITW Building Components Group Inc. shall not be responsible for any deviation from this drawing, any failure to build thetruss in conformance with ANSI/TPI 1, or for handling, shipping, installation and bracing of trusses. A seal on this drawing or cover pagelisting this drawing, indicates acceptance of professional engineering responsibility solely for the design shown. The suitability and use of thisdrawing for any structure is the responsibility of the Building Designer per ANSI/TPI 1 Sec.2. For more information see these web sites: Alpine: alpineitw.com; TPI: tpinst.org; SBCA: sbcacomponents.com; ICC: iccsafe.org; AWC: awc.org 155 Harlem Ave North Building, 4th Floor Glenview, IL 60025 Lumber Top chord: 4x2 SP #2; Bot chord: 4x2 SP #2; Webs: 4x2 SP #3; Special Loads ------(Lumber Dur.Fac.=1.00 / Plate Dur.Fac.=1.00) TC: From 200 plf at -0.12 to 200 plf at 0.00 TC: From 267 plf at 0.00 to 267 plf at 3.62 TC: From 67 plf at 3.62 to 67 plf at 19.71 TC: From 267 plf at 19.71 to 267 plf at 23.08 TC: From 200 plf at 23.08 to 200 plf at 23.21 BC: From 7 plf at 0.00 to 7 plf at 23.21 TC: 631 lb Conc. Load at 0.00 TC: 200 lb Conc. Load at 3.71,19.38 Plating Notes All plates are W =3X4 except as noted. Loading Bottom chord checked for 10.00 psf non-concurrent live load. Additional Notes + 2x6 continuous strongback. See detail STRBRIBR1014 for bracing and bridging recommendations. Truss must be installed as shown with top chord up. Maximum Reactions (lbs) Gravity Non-Gravity Loc R+/ R-/ Rh / Rw / U / RL AD 2448 /-/-/-/-/- P 1726 /-/-/-/-/- AD Brg Wid = 3.5 Min Req =1.5 (Truss) P Brg Wid = 3.5 Min Req =1.5 (Truss) Bearings AD & P are a rigid surface. Members not listed have forces less than 375# Maximum Top Chord Forces Per Ply (lbs) Chords Tens.Comp. A - B 0 -1299 B - C 0 -2823 C - D 0 -2823 D - E 0 -3447 E - F 0 -4116 F - G 0 -4455 G - H 0 -4455 Chords Tens.Comp. H - I 0 -4465 I - J 0 -4465 J - K 0 -4148 K - L 0 -3490 L - M 0 -3027 M - N 0 -1274 Maximum Bot Chord Forces Per Ply (lbs) Chords Tens.Comp. AC-AB 2458 0 AB-AA 3029 0 AA- Z 3858 0 Z - Y 3858 0 Y - X 4359 0 X - W 4539 0 Chords Tens.Comp. W -V 4539 0 V - U 4379 0 U - T 3898 0 T - S 3898 0 S - R 3087 0 R - Q 2509 0 Maximum Web Forces Per Ply (lbs) Webs Tens.Comp. AD- A 0 -2005 A -AD 8 -645 A -AC 1786 0 AC- B 0 -1752 B -AB 815 0 AB- D 0 -643 D -AA 632 0 AA- E 0 -621 E - Y 391 0 Webs Tens.Comp. U - K 385 0 K - S 0 -624 S - L 620 0 L - R 0 -681 R - M 887 0 M - Q 0 -1866 Q - N 1879 0 N - O 0 -1661 O - P 0 -1683 Loading Criteria (psf) TCLL:40.00 TCDL:10.00 BCLL:0.00 BCDL:5.00 Des Ld:55.00 NCBCLL:10.00 Soffit:2.00 Load Duration: 1.00 Spacing: 16.0 " Wind Criteria Wind Std:NA Speed:NA mph Enclosure: NA Category: NA EXP: NA Kzt: NA Mean Height: NA ft TCDL: NA psf BCDL: NA psf MWFRS Parallel Dist: NA C&C Dist a: NA Loc. from endwall: NA I: NA GCpi: NA Wind Duration: NA Snow Criteria (Pg,Pf in PSF) Pg: NA Ct: NA CAT: NA Pf: NA Ce: NA Lu: NA Cs: NA Snow Duration: NA Building Code: IRC 2021 TPI Std:2014 Rep Fac: Varies by Ld Case FT/RT:12(0)/10(0) Plate Type(s): WAVE Defl/CSI Criteria PP Deflection in loc L/defl L/# VERT(LL):0.283 H 963 360 VERT(CL):0.392 H 694 240 HORZ(LL):0.043 A - - HORZ(TL):0.060 A - - Creep Factor: 2.0 Max TC CSI:0.661 Max BC CSI:0.691 Max Web CSI:0.447 VIEW Ver: 24.01.01A.0510.10 Job Number:TS2207 84 LUMBER Truss Label:F21 Ply: 1 Qty:1 SEQN:120320 SY42 FROM: SC Cust: R 9462 JRef:1YaK94620001 T99 DrwNo:155.25.1735.00437 /BM 06/04/2025 3"8 3"8 5"22'11" 1"8 15'11"7'3"8 3" 0"8 2"8 8"8 5"12 2'6" (TYP) 2'6"12 2'6"12 3" 23'4" 1'10"8 1'10"8 2'0"11 2"3 19'6"12 17'6"1 19'8"12 2" 21'10" 2'1"4 22'0"3 2"3 23'4" 1'3"13 1'8" 1"8 ++ + A B C D E F G H I J K L M N O PQRSTUVWXYZAAABACAD AE 1X3 1X34X6 6X12 6X6 4X6 3X6 5X6 4X6 4X6 4X4 3X4 3X4 3X4 4X4 3X6 3X4 3X4 3X4 4X4 4X6 4X6 4X6 5X6 6X6 5X6 3X6 1X3 **WARNING**READ AND FOLLOW ALL NOTES ON THIS DRAW ING! **IMPORTANT**FURNISH THIS DRAW ING TO ALL CONTRACTORS INCLUDING THE INSTALLERSTrusses require extreme care in fabricating, handling, shipping, installing and bracing. Refer to and follow the latest edition of BCSI (BuildingComponent Safety Information, by TPI and SBCA) for safety practices prior to performing these functions. Installers shall provide temporarybracing per BCSI. Unless noted otherwise, top chord shall have properly attached structural sheathing and bottom chord shall have a properlyattached rigid ceiling. Locations shown for permanent lateral restraint of webs shall have continuous lateral restraint (CLR), installed withdiagonal bracing installed on the CLR per BCSI sections B3, B7, or B10, as applicable. Apply plates to each face of truss and position asshown above and on the Joint Details, unless noted otherwise. Refer to drawings 160A-Z for standard plate positions. Refer to job's GeneralNotes page for additional information.Alpine, a division of ITW Building Components Group Inc. shall not be responsible for any deviation from this drawing, any failure to build thetruss in conformance with ANSI/TPI 1, or for handling, shipping, installation and bracing of trusses. A seal on this drawing or cover pagelisting this drawing, indicates acceptance of professional engineering responsibility solely for the design shown. The suitability and use of thisdrawing for any structure is the responsibility of the Building Designer per ANSI/TPI 1 Sec.2. For more information see these web sites: Alpine: alpineitw.com; TPI: tpinst.org; SBCA: sbcacomponents.com; ICC: iccsafe.org; AWC: awc.org 155 Harlem Ave North Building, 4th Floor Glenview, IL 60025 Lumber Top chord: 4x2 SP #2; Bot chord: 4x2 SP #2; Webs: 4x2 SP #3; Special Loads ------(Lumber Dur.Fac.=1.00 / Plate Dur.Fac.=1.00) TC: From 200 plf at -0.12 to 200 plf at 0.00 TC: From 267 plf at 0.00 to 267 plf at 3.62 TC: From 67 plf at 3.62 to 67 plf at 19.71 TC: From 267 plf at 19.71 to 267 plf at 23.08 TC: From 200 plf at 23.08 to 200 plf at 23.21 BC: From 7 plf at 0.00 to 7 plf at 23.21 TC: 631 lb Conc. Load at 0.00 TC: 200 lb Conc. Load at 3.71,19.38 Plating Notes All plates are W =3X4 except as noted. Loading Bottom chord checked for 10.00 psf non-concurrent live load. Additional Notes + 2x6 continuous strongback. See detail STRBRIBR1014 for bracing and bridging recommendations. Truss must be installed as shown with top chord up. Maximum Reactions (lbs) Gravity Non-Gravity Loc R+/ R-/ Rh / Rw / U / RL AD 2448 /-/-/-/-/- P 1726 /-/-/-/-/- AD Brg Wid = 3.5 Min Req =1.5 (Truss) P Brg Wid = 3.5 Min Req =1.5 (Truss) Bearings AD & P are a rigid surface. Members not listed have forces less than 375# Maximum Top Chord Forces Per Ply (lbs) Chords Tens.Comp. A - B 0 -1299 B - C 0 -2823 C - D 0 -2823 D - E 0 -3447 E - F 0 -4116 F - G 0 -4455 G - H 0 -4455 Chords Tens.Comp. H - I 0 -4465 I - J 0 -4465 J - K 0 -4148 K - L 0 -3490 L - M 0 -3027 M - N 0 -1274 Maximum Bot Chord Forces Per Ply (lbs) Chords Tens.Comp. AC-AB 2458 0 AB-AA 3029 0 AA- Z 3858 0 Z - Y 3858 0 Y - X 4359 0 X - W 4539 0 Chords Tens.Comp. W -V 4539 0 V - U 4379 0 U - T 3898 0 T - S 3898 0 S - R 3087 0 R - Q 2509 0 Maximum Web Forces Per Ply (lbs) Webs Tens.Comp. AD- A 0 -2005 A -AD 8 -645 A -AC 1786 0 AC- B 0 -1752 B -AB 815 0 AB- D 0 -643 D -AA 632 0 AA- E 0 -621 E - Y 391 0 Webs Tens.Comp. U - K 385 0 K - S 0 -624 S - L 620 0 L - R 0 -681 R - M 887 0 M - Q 0 -1866 Q - N 1879 0 N - O 0 -1661 O - P 0 -1683 Loading Criteria (psf) TCLL:40.00 TCDL:10.00 BCLL:0.00 BCDL:5.00 Des Ld:55.00 NCBCLL:10.00 Soffit:2.00 Load Duration: 1.00 Spacing: 16.0 " Wind Criteria Wind Std:NA Speed:NA mph Enclosure: NA Category: NA EXP: NA Kzt: NA Mean Height: NA ft TCDL: NA psf BCDL: NA psf MWFRS Parallel Dist: NA C&C Dist a: NA Loc. from endwall: NA I: NA GCpi: NA Wind Duration: NA Snow Criteria (Pg,Pf in PSF) Pg: NA Ct: NA CAT: NA Pf: NA Ce: NA Lu: NA Cs: NA Snow Duration: NA Building Code: IRC 2021 TPI Std:2014 Rep Fac: Varies by Ld Case FT/RT:12(0)/10(0) Plate Type(s): WAVE Defl/CSI Criteria PP Deflection in loc L/defl L/# VERT(LL):0.283 H 963 360 VERT(CL):0.392 H 694 240 HORZ(LL):0.043 A - - HORZ(TL):0.060 A - - Creep Factor: 2.0 Max TC CSI:0.661 Max BC CSI:0.691 Max Web CSI:0.447 VIEW Ver: 24.01.01A.0510.10 Job Number:TS2207 84 LUMBER Truss Label:F21 Ply: 1 Qty:1 SEQN:120320 SY42 FROM: SC Cust: R 9462 JRef:1YaK94620001 T99 DrwNo:155.25.1735.00437 /BM 06/04/2025 3"8 3"8 5"22'11" 1"8 15'11"7'3"8 3" 0"8 2"8 8"8 5"12 2'6" (TYP) 2'6"12 2'6"12 3" 23'4" 1'10"8 1'10"8 2'0"11 2"3 19'6"12 17'6"1 19'8"12 2" 21'10" 2'1"4 22'0"3 2"3 23'4" 1'3"13 1'8" 1"8 ++ + A B C D E F G H I J K L M N O PQRSTUVWXYZAAABACAD AE 1X3 1X34X6 6X12 6X6 4X6 3X6 5X6 4X6 4X6 4X4 3X4 3X4 3X4 4X4 3X6 3X4 3X4 3X4 4X4 4X6 4X6 4X6 5X6 6X6 5X6 3X6 1X3 $%Lbl:F21?$ 06/04/2025 **WARNING**READ AND FOLLOW ALL NOTES ON THIS DRAW ING! **IMPORTANT**FURNISH THIS DRAW ING TO ALL CONTRACTORS INCLUDING THE INSTALLERSTrusses require extreme care in fabricating, handling, shipping, installing and bracing. Refer to and follow the latest edition of BCSI (BuildingComponent Safety Information, by TPI and SBCA) for safety practices prior to performing these functions. Installers shall provide temporarybracing per BCSI. Unless noted otherwise, top chord shall have properly attached structural sheathing and bottom chord shall have a properlyattached rigid ceiling. Locations shown for permanent lateral restraint of webs shall have continuous lateral restraint (CLR), installed withdiagonal bracing installed on the CLR per BCSI sections B3, B7, or B10, as applicable. Apply plates to each face of truss and position asshown above and on the Joint Details, unless noted otherwise. Refer to drawings 160A-Z for standard plate positions. Refer to job's GeneralNotes page for additional information.Alpine, a division of ITW Building Components Group Inc. shall not be responsible for any deviation from this drawing, any failure to build thetruss in conformance with ANSI/TPI 1, or for handling, shipping, installation and bracing of trusses. A seal on this drawing or cover pagelisting this drawing, indicates acceptance of professional engineering responsibility solely for the design shown. The suitability and use of thisdrawing for any structure is the responsibility of the Building Designer per ANSI/TPI 1 Sec.2. For more information see these web sites: Alpine: alpineitw.com; TPI: tpinst.org; SBCA: sbcacomponents.com; ICC: iccsafe.org; AWC: awc.org 155 Harlem Ave North Building, 4th Floor Glenview, IL 60025 Lumber Top chord: 4x2 SP #2; Bot chord: 4x2 SP #1; B2 4x2 SP #2; Webs: 4x2 SP #3; Special Loads ------(Lumber Dur.Fac.=1.00 / Plate Dur.Fac.=1.00) TC: From 67 plf at 0.00 to 67 plf at 23.08 BC: From 7 plf at 0.00 to 7 plf at 23.21 TC: 631 lb Conc. Load at 0.00 TC: 200 lb Conc. Load at 3.71,19.38 Loading Bottom chord checked for 10.00 psf non-concurrent live load. Additional Notes + 2x6 continuous strongback. See detail STRBRIBR1014 for bracing and bridging recommendations. Truss must be installed as shown with top chord up. Maximum Reactions (lbs) Gravity Non-Gravity Loc R+/ R-/ Rh / Rw / U / RL AC 1702 /-/-/-/-/- P 1022 /-/-/-/-/- AC Brg Wid = 3.5 Min Req =1.5 (Truss) P Brg Wid = 3.5 Min Req =1.5 (Truss) Bearings AC & P are a rigid surface. Members not listed have forces less than 375# Maximum Top Chord Forces Per Ply (lbs) Chords Tens.Comp. B - C 0 -706 C - D 0 -1827 D - E 0 -1827 E - F 0 -2417 F - G 0 -3038 G - H 0 -3038 Chords Tens.Comp. H - I 0 -3356 I - J 0 -3372 J - K 0 -3087 K - L 0 -2493 L - M 0 -2058 M - N 0 -798 Maximum Bot Chord Forces Per Ply (lbs) Chords Tens.Comp. AB-AA 1468 0 AA- Z 2027 0 Z - Y 2798 0 Y - X 3265 0 X - W 3439 0 W -V 3439 0 Chords Tens.Comp. V - U 3296 0 U - T 3296 0 T - S 2861 0 S - R 2119 0 R - Q 1554 0 Maximum Web Forces Per Ply (lbs) Webs Tens.Comp. A -AC 33 -550 AC- B 0 -1070 B -AB 1154 0 AB- C 0 -1210 C -AA 859 0 AA- E 0 -676 E - Z 619 0 Z - F 0 -604 F - Y 382 0 Webs Tens.Comp. K - S 0 -596 S - L 604 0 L - R 0 -744 R - M 913 0 M - Q 0 -1201 Q - N 1231 0 N - O 0 -1008 O - P 0 -1012 Loading Criteria (psf) TCLL:40.00 TCDL:10.00 BCLL:0.00 BCDL:5.00 Des Ld:55.00 NCBCLL:10.00 Soffit:2.00 Load Duration: 1.00 Spacing: 16.0 " Wind Criteria Wind Std:NA Speed:NA mph Enclosure: NA Category: NA EXP: NA Kzt: NA Mean Height: NA ft TCDL: NA psf BCDL: NA psf MWFRS Parallel Dist: NA C&C Dist a: NA Loc. from endwall: NA I: NA GCpi: NA Wind Duration: NA Snow Criteria (Pg,Pf in PSF) Pg: NA Ct: NA CAT: NA Pf: NA Ce: NA Lu: NA Cs: NA Snow Duration: NA Building Code: IRC 2021 TPI Std:2014 Rep Fac: Varies by Ld Case FT/RT:12(0)/10(0) Plate Type(s): WAVE, HS Defl/CSI Criteria PP Deflection in loc L/defl L/# VERT(LL):0.353 W 770 360 VERT(CL):0.492 W 552 240 HORZ(LL):0.058 A - - HORZ(TL):0.081 A - - Creep Factor: 2.0 Max TC CSI:0.532 Max BC CSI:0.993 Max Web CSI:0.586 VIEW Ver: 24.01.01A.0510.10 Job Number:TS2207 84 LUMBER Truss Label:F22 Ply: 1 Qty:1 SEQN:120322 SY42 FROM: SC Cust: R 9462 JRef:1YaK94620001 T100 DrwNo:155.25.1735.02527 /BM 06/04/2025 B2 3"8 3"8 5"22'11" 6" 2'6" (TYP) 8"8 5"12 2'6"12 2'6"12 1'1"12 3" 23'4" 1'8"++ + A B C D E F G H I J K L M NO PQRSTUVWXYZAAABACAD 1X3 1X3 3X3 1X33X3 4X4 4X6 4X4 1X3 4X6 3X4 3X4 3X3W=3X4 3X3 3X3 3X3 3X4 1X3 3X3W=H0310 3X3 3X3 3X3 3X3 3X3 4X4 4X4 4X6 4X4 2X4 1X3 **WARNING**READ AND FOLLOW ALL NOTES ON THIS DRAW ING! **IMPORTANT**FURNISH THIS DRAW ING TO ALL CONTRACTORS INCLUDING THE INSTALLERSTrusses require extreme care in fabricating, handling, shipping, installing and bracing. Refer to and follow the latest edition of BCSI (BuildingComponent Safety Information, by TPI and SBCA) for safety practices prior to performing these functions. Installers shall provide temporarybracing per BCSI. Unless noted otherwise, top chord shall have properly attached structural sheathing and bottom chord shall have a properlyattached rigid ceiling. Locations shown for permanent lateral restraint of webs shall have continuous lateral restraint (CLR), installed withdiagonal bracing installed on the CLR per BCSI sections B3, B7, or B10, as applicable. Apply plates to each face of truss and position asshown above and on the Joint Details, unless noted otherwise. Refer to drawings 160A-Z for standard plate positions. Refer to job's GeneralNotes page for additional information.Alpine, a division of ITW Building Components Group Inc. shall not be responsible for any deviation from this drawing, any failure to build thetruss in conformance with ANSI/TPI 1, or for handling, shipping, installation and bracing of trusses. A seal on this drawing or cover pagelisting this drawing, indicates acceptance of professional engineering responsibility solely for the design shown. The suitability and use of thisdrawing for any structure is the responsibility of the Building Designer per ANSI/TPI 1 Sec.2. For more information see these web sites: Alpine: alpineitw.com; TPI: tpinst.org; SBCA: sbcacomponents.com; ICC: iccsafe.org; AWC: awc.org 155 Harlem Ave North Building, 4th Floor Glenview, IL 60025 Lumber Top chord: 4x2 SP #2; Bot chord: 4x2 SP #1; B2 4x2 SP #2; Webs: 4x2 SP #3; Special Loads ------(Lumber Dur.Fac.=1.00 / Plate Dur.Fac.=1.00) TC: From 67 plf at 0.00 to 67 plf at 23.08 BC: From 7 plf at 0.00 to 7 plf at 23.21 TC: 631 lb Conc. Load at 0.00 TC: 200 lb Conc. Load at 3.71,19.38 Loading Bottom chord checked for 10.00 psf non-concurrent live load. Additional Notes + 2x6 continuous strongback. See detail STRBRIBR1014 for bracing and bridging recommendations. Truss must be installed as shown with top chord up. Maximum Reactions (lbs) Gravity Non-Gravity Loc R+/ R-/ Rh / Rw / U / RL AC 1702 /-/-/-/-/- P 1022 /-/-/-/-/- AC Brg Wid = 3.5 Min Req =1.5 (Truss) P Brg Wid = 3.5 Min Req =1.5 (Truss) Bearings AC & P are a rigid surface. Members not listed have forces less than 375# Maximum Top Chord Forces Per Ply (lbs) Chords Tens.Comp. B - C 0 -706 C - D 0 -1827 D - E 0 -1827 E - F 0 -2417 F - G 0 -3038 G - H 0 -3038 Chords Tens.Comp. H - I 0 -3356 I - J 0 -3372 J - K 0 -3087 K - L 0 -2493 L - M 0 -2058 M - N 0 -798 Maximum Bot Chord Forces Per Ply (lbs) Chords Tens.Comp. AB-AA 1468 0 AA- Z 2027 0 Z - Y 2798 0 Y - X 3265 0 X - W 3439 0 W -V 3439 0 Chords Tens.Comp. V - U 3296 0 U - T 3296 0 T - S 2861 0 S - R 2119 0 R - Q 1554 0 Maximum Web Forces Per Ply (lbs) Webs Tens.Comp. A -AC 33 -550 AC- B 0 -1070 B -AB 1154 0 AB- C 0 -1210 C -AA 859 0 AA- E 0 -676 E - Z 619 0 Z - F 0 -604 F - Y 382 0 Webs Tens.Comp. K - S 0 -596 S - L 604 0 L - R 0 -744 R - M 913 0 M - Q 0 -1201 Q - N 1231 0 N - O 0 -1008 O - P 0 -1012 Loading Criteria (psf) TCLL:40.00 TCDL:10.00 BCLL:0.00 BCDL:5.00 Des Ld:55.00 NCBCLL:10.00 Soffit:2.00 Load Duration: 1.00 Spacing: 16.0 " Wind Criteria Wind Std:NA Speed:NA mph Enclosure: NA Category: NA EXP: NA Kzt: NA Mean Height: NA ft TCDL: NA psf BCDL: NA psf MWFRS Parallel Dist: NA C&C Dist a: NA Loc. from endwall: NA I: NA GCpi: NA Wind Duration: NA Snow Criteria (Pg,Pf in PSF) Pg: NA Ct: NA CAT: NA Pf: NA Ce: NA Lu: NA Cs: NA Snow Duration: NA Building Code: IRC 2021 TPI Std:2014 Rep Fac: Varies by Ld Case FT/RT:12(0)/10(0) Plate Type(s): WAVE, HS Defl/CSI Criteria PP Deflection in loc L/defl L/# VERT(LL):0.353 W 770 360 VERT(CL):0.492 W 552 240 HORZ(LL):0.058 A - - HORZ(TL):0.081 A - - Creep Factor: 2.0 Max TC CSI:0.532 Max BC CSI:0.993 Max Web CSI:0.586 VIEW Ver: 24.01.01A.0510.10 Job Number:TS2207 84 LUMBER Truss Label:F22 Ply: 1 Qty:1 SEQN:120322 SY42 FROM: SC Cust: R 9462 JRef:1YaK94620001 T100 DrwNo:155.25.1735.02527 /BM 06/04/2025 B2 3"8 3"8 5"22'11" 6" 2'6" (TYP) 8"8 5"12 2'6"12 2'6"12 1'1"12 3" 23'4" 1'8"++ + A B C D E F G H I J K L M NO PQRSTUVWXYZAAABACAD 1X3 1X3 3X3 1X33X3 4X4 4X6 4X4 1X3 4X6 3X4 3X4 3X3W=3X4 3X3 3X3 3X3 3X4 1X3 3X3W=H0310 3X3 3X3 3X3 3X3 3X3 4X4 4X4 4X6 4X4 2X4 1X3 $%Lbl:F22?$ 06/04/2025 **WARNING**READ AND FOLLOW ALL NOTES ON THIS DRAW ING! **IMPORTANT**FURNISH THIS DRAW ING TO ALL CONTRACTORS INCLUDING THE INSTALLERSTrusses require extreme care in fabricating, handling, shipping, installing and bracing. Refer to and follow the latest edition of BCSI (BuildingComponent Safety Information, by TPI and SBCA) for safety practices prior to performing these functions. Installers shall provide temporarybracing per BCSI. Unless noted otherwise, top chord shall have properly attached structural sheathing and bottom chord shall have a properlyattached rigid ceiling. Locations shown for permanent lateral restraint of webs shall have continuous lateral restraint (CLR), installed withdiagonal bracing installed on the CLR per BCSI sections B3, B7, or B10, as applicable. Apply plates to each face of truss and position asshown above and on the Joint Details, unless noted otherwise. Refer to drawings 160A-Z for standard plate positions. Refer to job's GeneralNotes page for additional information.Alpine, a division of ITW Building Components Group Inc. shall not be responsible for any deviation from this drawing, any failure to build thetruss in conformance with ANSI/TPI 1, or for handling, shipping, installation and bracing of trusses. A seal on this drawing or cover pagelisting this drawing, indicates acceptance of professional engineering responsibility solely for the design shown. The suitability and use of thisdrawing for any structure is the responsibility of the Building Designer per ANSI/TPI 1 Sec.2. For more information see these web sites: Alpine: alpineitw.com; TPI: tpinst.org; SBCA: sbcacomponents.com; ICC: iccsafe.org; AWC: awc.org 155 Harlem Ave North Building, 4th Floor Glenview, IL 60025 Lumber Top chord: 4x2 SP #2; Bot chord: 4x2 SP #2; Webs: 4x2 SP #3; Plating Notes All plates are 1X3 except as noted. Loading Bottom chord checked for 10.00 psf non-concurrent live load. Additional Notes + 2x6 continuous strongback. See detail STRBRIBR1014 for bracing and bridging recommendations. Truss must be installed as shown with top chord up. Maximum Reactions (lbs), or *=PLF Gravity Non-Gravity Loc R+/ R-/ Rh / Rw / U / RL U*146 /-/-/-/-/- K 336 /-/-/-/-/- U Brg Wid = 96.0 Min Req =- K Brg Wid = 3.5 Min Req =1.5 (Truss) Bearings U & K are a rigid surface. Members not listed have forces less than 375# Maximum Web Forces Per Ply (lbs) Webs Tens.Comp. O - G 0 -382 Webs Tens.Comp. G - N 378 0 Loading Criteria (psf) TCLL:40.00 TCDL:10.00 BCLL:0.00 BCDL:5.00 Des Ld:55.00 NCBCLL:10.00 Soffit:2.00 Load Duration: 1.00 Spacing: 24.0 " Wind Criteria Wind Std:NA Speed:NA mph Enclosure: NA Category: NA EXP: NA Kzt: NA Mean Height: NA ft TCDL: NA psf BCDL: NA psf MWFRS Parallel Dist: NA C&C Dist a: NA Loc. from endwall: NA I: NA GCpi: NA Wind Duration: NA Snow Criteria (Pg,Pf in PSF) Pg: NA Ct: NA CAT: NA Pf: NA Ce: NA Lu: NA Cs: NA Snow Duration: NA Building Code: IRC 2021 TPI Std:2014 Rep Fac: Yes FT/RT:20(0)/10(0) Plate Type(s): WAVE Defl/CSI Criteria PP Deflection in loc L/defl L/# VERT(LL):0.030 I 999 360 VERT(CL):0.044 I 999 240 HORZ(LL):-0.013 J - - HORZ(TL):0.020 J - - Creep Factor: 2.0 Max TC CSI:0.435 Max BC CSI:0.348 Max Web CSI:0.180 VIEW Ver: 24.01.01A.0510.10 Job Number:TS2207 84 LUMBER Truss Label:F23 Ply: 1 Qty:1 SEQN:120324 SY42 FROM: SC Cust: R 9462 JRef:1YaK94620001 T101 DrwNo:155.25.1735.03823 /BM 06/04/2025 13'8"8 1'4" (TYP) 3"7'8"4 1'4"8 1'7"12 2'6"3" 3" 3" 1'3"4 1'0"4 7'9" 6'5"12 9'4"8 1'7"8 10'10" 1'5"8 13'8"8 2'10"8 1'8" + A G H I J KLMNOU 2X4 2X4 2X4 3X4 3X3 3X3 3X3 3X4 2X4 **WARNING**READ AND FOLLOW ALL NOTES ON THIS DRAW ING! **IMPORTANT**FURNISH THIS DRAW ING TO ALL CONTRACTORS INCLUDING THE INSTALLERSTrusses require extreme care in fabricating, handling, shipping, installing and bracing. Refer to and follow the latest edition of BCSI (BuildingComponent Safety Information, by TPI and SBCA) for safety practices prior to performing these functions. Installers shall provide temporarybracing per BCSI. Unless noted otherwise, top chord shall have properly attached structural sheathing and bottom chord shall have a properlyattached rigid ceiling. Locations shown for permanent lateral restraint of webs shall have continuous lateral restraint (CLR), installed withdiagonal bracing installed on the CLR per BCSI sections B3, B7, or B10, as applicable. Apply plates to each face of truss and position asshown above and on the Joint Details, unless noted otherwise. Refer to drawings 160A-Z for standard plate positions. Refer to job's GeneralNotes page for additional information.Alpine, a division of ITW Building Components Group Inc. shall not be responsible for any deviation from this drawing, any failure to build thetruss in conformance with ANSI/TPI 1, or for handling, shipping, installation and bracing of trusses. A seal on this drawing or cover pagelisting this drawing, indicates acceptance of professional engineering responsibility solely for the design shown. The suitability and use of thisdrawing for any structure is the responsibility of the Building Designer per ANSI/TPI 1 Sec.2. For more information see these web sites: Alpine: alpineitw.com; TPI: tpinst.org; SBCA: sbcacomponents.com; ICC: iccsafe.org; AWC: awc.org 155 Harlem Ave North Building, 4th Floor Glenview, IL 60025 Lumber Top chord: 4x2 SP #2; Bot chord: 4x2 SP #2; Webs: 4x2 SP #3; Plating Notes All plates are 1X3 except as noted. Loading Bottom chord checked for 10.00 psf non-concurrent live load. Additional Notes + 2x6 continuous strongback. See detail STRBRIBR1014 for bracing and bridging recommendations. Truss must be installed as shown with top chord up. Maximum Reactions (lbs), or *=PLF Gravity Non-Gravity Loc R+/ R-/ Rh / Rw / U / RL U*146 /-/-/-/-/- K 336 /-/-/-/-/- U Brg Wid = 96.0 Min Req =- K Brg Wid = 3.5 Min Req =1.5 (Truss) Bearings U & K are a rigid surface. Members not listed have forces less than 375# Maximum Web Forces Per Ply (lbs) Webs Tens.Comp. O - G 0 -382 Webs Tens.Comp. G - N 378 0 Loading Criteria (psf) TCLL:40.00 TCDL:10.00 BCLL:0.00 BCDL:5.00 Des Ld:55.00 NCBCLL:10.00 Soffit:2.00 Load Duration: 1.00 Spacing: 24.0 " Wind Criteria Wind Std:NA Speed:NA mph Enclosure: NA Category: NA EXP: NA Kzt: NA Mean Height: NA ft TCDL: NA psf BCDL: NA psf MWFRS Parallel Dist: NA C&C Dist a: NA Loc. from endwall: NA I: NA GCpi: NA Wind Duration: NA Snow Criteria (Pg,Pf in PSF) Pg: NA Ct: NA CAT: NA Pf: NA Ce: NA Lu: NA Cs: NA Snow Duration: NA Building Code: IRC 2021 TPI Std:2014 Rep Fac: Yes FT/RT:20(0)/10(0) Plate Type(s): WAVE Defl/CSI Criteria PP Deflection in loc L/defl L/# VERT(LL):0.030 I 999 360 VERT(CL):0.044 I 999 240 HORZ(LL):-0.013 J - - HORZ(TL):0.020 J - - Creep Factor: 2.0 Max TC CSI:0.435 Max BC CSI:0.348 Max Web CSI:0.180 VIEW Ver: 24.01.01A.0510.10 Job Number:TS2207 84 LUMBER Truss Label:F23 Ply: 1 Qty:1 SEQN:120324 SY42 FROM: SC Cust: R 9462 JRef:1YaK94620001 T101 DrwNo:155.25.1735.03823 /BM 06/04/2025 13'8"8 1'4" (TYP) 3"7'8"4 1'4"8 1'7"12 2'6"3" 3" 3" 1'3"4 1'0"4 7'9" 6'5"12 9'4"8 1'7"8 10'10" 1'5"8 13'8"8 2'10"8 1'8" + A G H I J KLMNOU 2X4 2X4 2X4 3X4 3X3 3X3 3X3 3X4 2X4 $%Lbl:F23?$ 06/04/2025 **WARNING**READ AND FOLLOW ALL NOTES ON THIS DRAW ING! **IMPORTANT**FURNISH THIS DRAW ING TO ALL CONTRACTORS INCLUDING THE INSTALLERSTrusses require extreme care in fabricating, handling, shipping, installing and bracing. Refer to and follow the latest edition of BCSI (BuildingComponent Safety Information, by TPI and SBCA) for safety practices prior to performing these functions. Installers shall provide temporarybracing per BCSI. Unless noted otherwise, top chord shall have properly attached structural sheathing and bottom chord shall have a properlyattached rigid ceiling. Locations shown for permanent lateral restraint of webs shall have continuous lateral restraint (CLR), installed withdiagonal bracing installed on the CLR per BCSI sections B3, B7, or B10, as applicable. Apply plates to each face of truss and position asshown above and on the Joint Details, unless noted otherwise. Refer to drawings 160A-Z for standard plate positions. Refer to job's GeneralNotes page for additional information.Alpine, a division of ITW Building Components Group Inc. shall not be responsible for any deviation from this drawing, any failure to build thetruss in conformance with ANSI/TPI 1, or for handling, shipping, installation and bracing of trusses. A seal on this drawing or cover pagelisting this drawing, indicates acceptance of professional engineering responsibility solely for the design shown. The suitability and use of thisdrawing for any structure is the responsibility of the Building Designer per ANSI/TPI 1 Sec.2. For more information see these web sites: Alpine: alpineitw.com; TPI: tpinst.org; SBCA: sbcacomponents.com; ICC: iccsafe.org; AWC: awc.org 155 Harlem Ave North Building, 4th Floor Glenview, IL 60025 Lumber Top chord: 4x2 SP #2; Bot chord: 4x2 SP #2; Webs: 4x2 SP #3; Special Loads ------(Lumber Dur.Fac.=1.00 / Plate Dur.Fac.=1.00) TC: From 347 plf at 0.00 to 347 plf at 7.42 TC: From 280 plf at 7.42 to 280 plf at 7.67 BC: From 7 plf at 0.00 to 7 plf at 7.42 Loading Bottom chord checked for 10.00 psf non-concurrent live load. Additional Notes Truss must be installed as shown with top chord up. Maximum Reactions (lbs) Gravity Non-Gravity Loc R+/ R-/ Rh / Rw / U / RL J 1310 /-/-/-/-/- E 1310 /-/-/-/-/- J Brg Wid = 3.5 Min Req =1.5 (Truss) E Brg Wid = 3.5 Min Req =1.5 (Truss) Bearings J & E are a rigid surface. Members not listed have forces less than 375# Maximum Top Chord Forces Per Ply (lbs) Chords Tens.Comp. A - B 0 -749 B - C 0 -1463 Chords Tens.Comp. C - D 0 -749 Maximum Bot Chord Forces Per Ply (lbs) Chords Tens.Comp. I - H 1463 0 H - G 1463 0 Chords Tens.Comp. G - F 1463 0 Maximum Web Forces Per Ply (lbs) Webs Tens.Comp. A - J 263 -1536 A - I 1066 0 I - B 0 -1080 Webs Tens.Comp. C - F 0 -1080 F - D 1066 0 D - E 0 -1536 Loading Criteria (psf) TCLL:40.00 TCDL:10.00 BCLL:0.00 BCDL:5.00 Des Ld:55.00 NCBCLL:10.00 Soffit:2.00 Load Duration: 1.00 Spacing: 16.0 " Wind Criteria Wind Std:NA Speed:NA mph Enclosure: NA Category: NA EXP: NA Kzt: NA Mean Height: NA ft TCDL: NA psf BCDL: NA psf MWFRS Parallel Dist: NA C&C Dist a: NA Loc. from endwall: NA I: NA GCpi: NA Wind Duration: NA Snow Criteria (Pg,Pf in PSF) Pg: NA Ct: NA CAT: NA Pf: NA Ce: NA Lu: NA Cs: NA Snow Duration: NA Building Code: IRC 2021 TPI Std:2014 Rep Fac: Varies by Ld Case FT/RT:12(0)/10(0) Plate Type(s): WAVE Defl/CSI Criteria PP Deflection in loc L/defl L/# VERT(LL):0.047 B 999 360 VERT(CL):0.066 B 999 240 HORZ(LL):0.005 B - - HORZ(TL):0.007 B - - Creep Factor: 2.0 Max TC CSI:0.704 Max BC CSI:0.333 Max Web CSI:0.507 VIEW Ver: 24.01.01A.0510.10 Job Number:TS2207 84 LUMBER Truss Label:F24 Ply: 1 Qty:1 SEQN:120330 SY42 FROM: SC Cust: R 9462 JRef:1YaK94620001 T102 DrwNo:155.25.1735.05227 /BM 06/04/2025 7'5" 3"2'6" (TYP) 3" 2'10"8 2'10"8 4'6"8 1'8" 7'5" 2'10"8 1'8" 1"8 A B C D EFGHIJ 5X6 3X4 5X6 4X4 3X6 3X6 4X4 5X6 5X6 3X4 **WARNING**READ AND FOLLOW ALL NOTES ON THIS DRAW ING! **IMPORTANT**FURNISH THIS DRAW ING TO ALL CONTRACTORS INCLUDING THE INSTALLERSTrusses require extreme care in fabricating, handling, shipping, installing and bracing. Refer to and follow the latest edition of BCSI (BuildingComponent Safety Information, by TPI and SBCA) for safety practices prior to performing these functions. Installers shall provide temporarybracing per BCSI. Unless noted otherwise, top chord shall have properly attached structural sheathing and bottom chord shall have a properlyattached rigid ceiling. Locations shown for permanent lateral restraint of webs shall have continuous lateral restraint (CLR), installed withdiagonal bracing installed on the CLR per BCSI sections B3, B7, or B10, as applicable. Apply plates to each face of truss and position asshown above and on the Joint Details, unless noted otherwise. Refer to drawings 160A-Z for standard plate positions. Refer to job's GeneralNotes page for additional information.Alpine, a division of ITW Building Components Group Inc. shall not be responsible for any deviation from this drawing, any failure to build thetruss in conformance with ANSI/TPI 1, or for handling, shipping, installation and bracing of trusses. A seal on this drawing or cover pagelisting this drawing, indicates acceptance of professional engineering responsibility solely for the design shown. The suitability and use of thisdrawing for any structure is the responsibility of the Building Designer per ANSI/TPI 1 Sec.2. For more information see these web sites: Alpine: alpineitw.com; TPI: tpinst.org; SBCA: sbcacomponents.com; ICC: iccsafe.org; AWC: awc.org 155 Harlem Ave North Building, 4th Floor Glenview, IL 60025 Lumber Top chord: 4x2 SP #2; Bot chord: 4x2 SP #2; Webs: 4x2 SP #3; Special Loads ------(Lumber Dur.Fac.=1.00 / Plate Dur.Fac.=1.00) TC: From 347 plf at 0.00 to 347 plf at 7.42 TC: From 280 plf at 7.42 to 280 plf at 7.67 BC: From 7 plf at 0.00 to 7 plf at 7.42 Loading Bottom chord checked for 10.00 psf non-concurrent live load. Additional Notes Truss must be installed as shown with top chord up. Maximum Reactions (lbs) Gravity Non-Gravity Loc R+/ R-/ Rh / Rw / U / RL J 1310 /-/-/-/-/- E 1310 /-/-/-/-/- J Brg Wid = 3.5 Min Req =1.5 (Truss) E Brg Wid = 3.5 Min Req =1.5 (Truss) Bearings J & E are a rigid surface. Members not listed have forces less than 375# Maximum Top Chord Forces Per Ply (lbs) Chords Tens.Comp. A - B 0 -749 B - C 0 -1463 Chords Tens.Comp. C - D 0 -749 Maximum Bot Chord Forces Per Ply (lbs) Chords Tens.Comp. I - H 1463 0 H - G 1463 0 Chords Tens.Comp. G - F 1463 0 Maximum Web Forces Per Ply (lbs) Webs Tens.Comp. A - J 263 -1536 A - I 1066 0 I - B 0 -1080 Webs Tens.Comp. C - F 0 -1080 F - D 1066 0 D - E 0 -1536 Loading Criteria (psf) TCLL:40.00 TCDL:10.00 BCLL:0.00 BCDL:5.00 Des Ld:55.00 NCBCLL:10.00 Soffit:2.00 Load Duration: 1.00 Spacing: 16.0 " Wind Criteria Wind Std:NA Speed:NA mph Enclosure: NA Category: NA EXP: NA Kzt: NA Mean Height: NA ft TCDL: NA psf BCDL: NA psf MWFRS Parallel Dist: NA C&C Dist a: NA Loc. from endwall: NA I: NA GCpi: NA Wind Duration: NA Snow Criteria (Pg,Pf in PSF) Pg: NA Ct: NA CAT: NA Pf: NA Ce: NA Lu: NA Cs: NA Snow Duration: NA Building Code: IRC 2021 TPI Std:2014 Rep Fac: Varies by Ld Case FT/RT:12(0)/10(0) Plate Type(s): WAVE Defl/CSI Criteria PP Deflection in loc L/defl L/# VERT(LL):0.047 B 999 360 VERT(CL):0.066 B 999 240 HORZ(LL):0.005 B - - HORZ(TL):0.007 B - - Creep Factor: 2.0 Max TC CSI:0.704 Max BC CSI:0.333 Max Web CSI:0.507 VIEW Ver: 24.01.01A.0510.10 Job Number:TS2207 84 LUMBER Truss Label:F24 Ply: 1 Qty:1 SEQN:120330 SY42 FROM: SC Cust: R 9462 JRef:1YaK94620001 T102 DrwNo:155.25.1735.05227 /BM 06/04/2025 7'5" 3"2'6" (TYP) 3" 2'10"8 2'10"8 4'6"8 1'8" 7'5" 2'10"8 1'8" 1"8 A B C D EFGHIJ 5X6 3X4 5X6 4X4 3X6 3X6 4X4 5X6 5X6 3X4 $%Lbl:F24?$ 06/04/2025 **WARNING**READ AND FOLLOW ALL NOTES ON THIS DRAW ING! **IMPORTANT**FURNISH THIS DRAW ING TO ALL CONTRACTORS INCLUDING THE INSTALLERSTrusses require extreme care in fabricating, handling, shipping, installing and bracing. Refer to and follow the latest edition of BCSI (BuildingComponent Safety Information, by TPI and SBCA) for safety practices prior to performing these functions. Installers shall provide temporarybracing per BCSI. Unless noted otherwise, top chord shall have properly attached structural sheathing and bottom chord shall have a properlyattached rigid ceiling. Locations shown for permanent lateral restraint of webs shall have continuous lateral restraint (CLR), installed withdiagonal bracing installed on the CLR per BCSI sections B3, B7, or B10, as applicable. Apply plates to each face of truss and position asshown above and on the Joint Details, unless noted otherwise. Refer to drawings 160A-Z for standard plate positions. Refer to job's GeneralNotes page for additional information.Alpine, a division of ITW Building Components Group Inc. shall not be responsible for any deviation from this drawing, any failure to build thetruss in conformance with ANSI/TPI 1, or for handling, shipping, installation and bracing of trusses. A seal on this drawing or cover pagelisting this drawing, indicates acceptance of professional engineering responsibility solely for the design shown. The suitability and use of thisdrawing for any structure is the responsibility of the Building Designer per ANSI/TPI 1 Sec.2. For more information see these web sites: Alpine: alpineitw.com; TPI: tpinst.org; SBCA: sbcacomponents.com; ICC: iccsafe.org; AWC: awc.org 155 Harlem Ave North Building, 4th Floor Glenview, IL 60025 Lumber Top chord: 4x2 SP #2; Bot chord: 4x2 SP #2; Webs: 4x2 SP #3; Bracing Sheathing is required for any longitudinal(drag) forces. All connections to be designed by the building designer. Fasten rated sheathing to one face of this frame. Plating Notes All plates are 1X3 except as noted. Loading Bottom chord checked for 10.00 psf non-concurrent live load. Additional Notes Truss must be installed as shown with top chord up. Maximum Reactions (lbs), or *=PLF Gravity Non-Gravity Loc R+/ R-/ Rh / Rw / U / RL AA*108 /-/-/-/-/- AA Brg Wid = 191 Min Req =- Bearing AA is a rigid surface. Members not listed have forces less than 375# Loading Criteria (psf) TCLL:40.00 TCDL:10.00 BCLL:0.00 BCDL:5.00 Des Ld:55.00 NCBCLL:10.00 Soffit:2.00 Load Duration: 1.00 Spacing: 24.0 " Wind Criteria Wind Std:NA Speed:NA mph Enclosure: NA Category: NA EXP: NA Kzt: NA Mean Height: NA ft TCDL: NA psf BCDL: NA psf MWFRS Parallel Dist: NA C&C Dist a: NA Loc. from endwall: NA I: NA GCpi: NA Wind Duration: NA Snow Criteria (Pg,Pf in PSF) Pg: NA Ct: NA CAT: NA Pf: NA Ce: NA Lu: NA Cs: NA Snow Duration: NA Building Code: IRC 2021 TPI Std:2014 Rep Fac: Yes FT/RT:20(0)/10(0) Plate Type(s): WAVE Defl/CSI Criteria PP Deflection in loc L/defl L/# VERT(LL):0.000 G 999 360 VERT(CL):0.000 G 999 240 HORZ(LL):0.000 B - - HORZ(TL):0.000 B - - Creep Factor: 2.0 Max TC CSI:0.087 Max BC CSI:0.018 Max Web CSI:0.032 VIEW Ver: 24.01.01A.0510.10 Job Number:TS2207 84 LUMBER Truss Label:KW1 Ply: 1 Qty:1 SEQN:120462 SY42 FROM: SC Cust: R 9462 JRef:1YaK94620001 T103 DrwNo:155.25.1735.18447 /BM 06/04/2025 3"12 15'11"8 1'2"8 1'4" (TYP) 3"7'8"12 (TYP) 3" 1'8" A G M O U AA 1X3 2X4 4X4 4X4 2X4 1X3 **WARNING**READ AND FOLLOW ALL NOTES ON THIS DRAW ING! **IMPORTANT**FURNISH THIS DRAW ING TO ALL CONTRACTORS INCLUDING THE INSTALLERSTrusses require extreme care in fabricating, handling, shipping, installing and bracing. Refer to and follow the latest edition of BCSI (BuildingComponent Safety Information, by TPI and SBCA) for safety practices prior to performing these functions. Installers shall provide temporarybracing per BCSI. Unless noted otherwise, top chord shall have properly attached structural sheathing and bottom chord shall have a properlyattached rigid ceiling. Locations shown for permanent lateral restraint of webs shall have continuous lateral restraint (CLR), installed withdiagonal bracing installed on the CLR per BCSI sections B3, B7, or B10, as applicable. Apply plates to each face of truss and position asshown above and on the Joint Details, unless noted otherwise. Refer to drawings 160A-Z for standard plate positions. Refer to job's GeneralNotes page for additional information.Alpine, a division of ITW Building Components Group Inc. shall not be responsible for any deviation from this drawing, any failure to build thetruss in conformance with ANSI/TPI 1, or for handling, shipping, installation and bracing of trusses. A seal on this drawing or cover pagelisting this drawing, indicates acceptance of professional engineering responsibility solely for the design shown. The suitability and use of thisdrawing for any structure is the responsibility of the Building Designer per ANSI/TPI 1 Sec.2. For more information see these web sites: Alpine: alpineitw.com; TPI: tpinst.org; SBCA: sbcacomponents.com; ICC: iccsafe.org; AWC: awc.org 155 Harlem Ave North Building, 4th Floor Glenview, IL 60025 Lumber Top chord: 4x2 SP #2; Bot chord: 4x2 SP #2; Webs: 4x2 SP #3; Bracing Sheathing is required for any longitudinal(drag) forces. All connections to be designed by the building designer. Fasten rated sheathing to one face of this frame. Plating Notes All plates are 1X3 except as noted. Loading Bottom chord checked for 10.00 psf non-concurrent live load. Additional Notes Truss must be installed as shown with top chord up. Maximum Reactions (lbs), or *=PLF Gravity Non-Gravity Loc R+/ R-/ Rh / Rw / U / RL AA*108 /-/-/-/-/- AA Brg Wid = 191 Min Req =- Bearing AA is a rigid surface. Members not listed have forces less than 375# Loading Criteria (psf) TCLL:40.00 TCDL:10.00 BCLL:0.00 BCDL:5.00 Des Ld:55.00 NCBCLL:10.00 Soffit:2.00 Load Duration: 1.00 Spacing: 24.0 " Wind Criteria Wind Std:NA Speed:NA mph Enclosure: NA Category: NA EXP: NA Kzt: NA Mean Height: NA ft TCDL: NA psf BCDL: NA psf MWFRS Parallel Dist: NA C&C Dist a: NA Loc. from endwall: NA I: NA GCpi: NA Wind Duration: NA Snow Criteria (Pg,Pf in PSF) Pg: NA Ct: NA CAT: NA Pf: NA Ce: NA Lu: NA Cs: NA Snow Duration: NA Building Code: IRC 2021 TPI Std:2014 Rep Fac: Yes FT/RT:20(0)/10(0) Plate Type(s): WAVE Defl/CSI Criteria PP Deflection in loc L/defl L/# VERT(LL):0.000 G 999 360 VERT(CL):0.000 G 999 240 HORZ(LL):0.000 B - - HORZ(TL):0.000 B - - Creep Factor: 2.0 Max TC CSI:0.087 Max BC CSI:0.018 Max Web CSI:0.032 VIEW Ver: 24.01.01A.0510.10 Job Number:TS2207 84 LUMBER Truss Label:KW1 Ply: 1 Qty:1 SEQN:120462 SY42 FROM: SC Cust: R 9462 JRef:1YaK94620001 T103 DrwNo:155.25.1735.18447 /BM 06/04/2025 3"12 15'11"8 1'2"8 1'4" (TYP) 3"7'8"12 (TYP) 3" 1'8" A G M O U AA 1X3 2X4 4X4 4X4 2X4 1X3 $%Lbl:KW1?$ 06/04/2025 **WARNING**READ AND FOLLOW ALL NOTES ON THIS DRAW ING! **IMPORTANT**FURNISH THIS DRAW ING TO ALL CONTRACTORS INCLUDING THE INSTALLERSTrusses require extreme care in fabricating, handling, shipping, installing and bracing. Refer to and follow the latest edition of BCSI (BuildingComponent Safety Information, by TPI and SBCA) for safety practices prior to performing these functions. Installers shall provide temporarybracing per BCSI. Unless noted otherwise, top chord shall have properly attached structural sheathing and bottom chord shall have a properlyattached rigid ceiling. Locations shown for permanent lateral restraint of webs shall have continuous lateral restraint (CLR), installed withdiagonal bracing installed on the CLR per BCSI sections B3, B7, or B10, as applicable. Apply plates to each face of truss and position asshown above and on the Joint Details, unless noted otherwise. Refer to drawings 160A-Z for standard plate positions. Refer to job's GeneralNotes page for additional information.Alpine, a division of ITW Building Components Group Inc. shall not be responsible for any deviation from this drawing, any failure to build thetruss in conformance with ANSI/TPI 1, or for handling, shipping, installation and bracing of trusses. A seal on this drawing or cover pagelisting this drawing, indicates acceptance of professional engineering responsibility solely for the design shown. The suitability and use of thisdrawing for any structure is the responsibility of the Building Designer per ANSI/TPI 1 Sec.2. For more information see these web sites: Alpine: alpineitw.com; TPI: tpinst.org; SBCA: sbcacomponents.com; ICC: iccsafe.org; AWC: awc.org 155 Harlem Ave North Building, 4th Floor Glenview, IL 60025 Lumber Top chord: 4x2 SP #2; Bot chord: 4x2 SP #2; Webs: 4x2 SP #3; Plating Notes All plates are 1X3 except as noted. Loading Bottom chord checked for 10.00 psf non-concurrent live load. Additional Notes + 2x6 continuous strongback. See detail STRBRIBR1014 for bracing and bridging recommendations. Truss must be installed as shown with top chord up. Maximum Reactions (lbs), or *=PLF Gravity Non-Gravity Loc R+/ R-/ Rh / Rw / U / RL AO*72 /-/-/-/-/- AB*75 /-/-/-/-/- AO Brg Wid = 191 Min Req =- AB Brg Wid = 87.5 Min Req =- Bearings AO & AB are a rigid surface. Members not listed have forces less than 375# Loading Criteria (psf) TCLL:40.00 TCDL:10.00 BCLL:0.00 BCDL:5.00 Des Ld:55.00 NCBCLL:10.00 Soffit:2.00 Load Duration: 1.00 Spacing: 16.0 " Wind Criteria Wind Std:NA Speed:NA mph Enclosure: NA Category: NA EXP: NA Kzt: NA Mean Height: NA ft TCDL: NA psf BCDL: NA psf MWFRS Parallel Dist: NA C&C Dist a: NA Loc. from endwall: NA I: NA GCpi: NA Wind Duration: NA Snow Criteria (Pg,Pf in PSF) Pg: NA Ct: NA CAT: NA Pf: NA Ce: NA Lu: NA Cs: NA Snow Duration: NA Building Code: IRC 2021 TPI Std:2014 Rep Fac: Yes FT/RT:20(0)/10(0) Plate Type(s): WAVE Defl/CSI Criteria PP Deflection in loc L/defl L/# VERT(LL):0.001 B 999 360 VERT(CL):0.001 B 999 240 HORZ(LL):0.001 T - - HORZ(TL):0.001 T - - Creep Factor: 2.0 Max TC CSI:0.070 Max BC CSI:0.017 Max Web CSI:0.023 VIEW Ver: 24.01.01A.0510.10 Job Number:TS2207 84 LUMBER Truss Label:KW2 Ply: 1 Qty:1 SEQN:120464 SY42 FROM: SC Cust: R 9462 JRef:1YaK94620001 T104 DrwNo:155.25.1735.21720 /BM 06/04/2025 3"8 3"8 1"8 23'2"8 1'8"8 1'4" (TYP) 5"4 22'6"4 3" 23'4" 7"8 7"8 1'9"4 1'1"12 23'1" 21'3"12 23'4" 3" 1'8" + A B I T V ABAN AO 1X3 1X3 3X3 3X3 W=3X4 W=3X4 2X4 1X3 **WARNING**READ AND FOLLOW ALL NOTES ON THIS DRAW ING! **IMPORTANT**FURNISH THIS DRAW ING TO ALL CONTRACTORS INCLUDING THE INSTALLERSTrusses require extreme care in fabricating, handling, shipping, installing and bracing. Refer to and follow the latest edition of BCSI (BuildingComponent Safety Information, by TPI and SBCA) for safety practices prior to performing these functions. Installers shall provide temporarybracing per BCSI. Unless noted otherwise, top chord shall have properly attached structural sheathing and bottom chord shall have a properlyattached rigid ceiling. Locations shown for permanent lateral restraint of webs shall have continuous lateral restraint (CLR), installed withdiagonal bracing installed on the CLR per BCSI sections B3, B7, or B10, as applicable. Apply plates to each face of truss and position asshown above and on the Joint Details, unless noted otherwise. Refer to drawings 160A-Z for standard plate positions. Refer to job's GeneralNotes page for additional information.Alpine, a division of ITW Building Components Group Inc. shall not be responsible for any deviation from this drawing, any failure to build thetruss in conformance with ANSI/TPI 1, or for handling, shipping, installation and bracing of trusses. A seal on this drawing or cover pagelisting this drawing, indicates acceptance of professional engineering responsibility solely for the design shown. The suitability and use of thisdrawing for any structure is the responsibility of the Building Designer per ANSI/TPI 1 Sec.2. For more information see these web sites: Alpine: alpineitw.com; TPI: tpinst.org; SBCA: sbcacomponents.com; ICC: iccsafe.org; AWC: awc.org 155 Harlem Ave North Building, 4th Floor Glenview, IL 60025 Lumber Top chord: 4x2 SP #2; Bot chord: 4x2 SP #2; Webs: 4x2 SP #3; Plating Notes All plates are 1X3 except as noted. Loading Bottom chord checked for 10.00 psf non-concurrent live load. Additional Notes + 2x6 continuous strongback. See detail STRBRIBR1014 for bracing and bridging recommendations. Truss must be installed as shown with top chord up. Maximum Reactions (lbs), or *=PLF Gravity Non-Gravity Loc R+/ R-/ Rh / Rw / U / RL AO*72 /-/-/-/-/- AB*75 /-/-/-/-/- AO Brg Wid = 191 Min Req =- AB Brg Wid = 87.5 Min Req =- Bearings AO & AB are a rigid surface. Members not listed have forces less than 375# Loading Criteria (psf) TCLL:40.00 TCDL:10.00 BCLL:0.00 BCDL:5.00 Des Ld:55.00 NCBCLL:10.00 Soffit:2.00 Load Duration: 1.00 Spacing: 16.0 " Wind Criteria Wind Std:NA Speed:NA mph Enclosure: NA Category: NA EXP: NA Kzt: NA Mean Height: NA ft TCDL: NA psf BCDL: NA psf MWFRS Parallel Dist: NA C&C Dist a: NA Loc. from endwall: NA I: NA GCpi: NA Wind Duration: NA Snow Criteria (Pg,Pf in PSF) Pg: NA Ct: NA CAT: NA Pf: NA Ce: NA Lu: NA Cs: NA Snow Duration: NA Building Code: IRC 2021 TPI Std:2014 Rep Fac: Yes FT/RT:20(0)/10(0) Plate Type(s): WAVE Defl/CSI Criteria PP Deflection in loc L/defl L/# VERT(LL):0.001 B 999 360 VERT(CL):0.001 B 999 240 HORZ(LL):0.001 T - - HORZ(TL):0.001 T - - Creep Factor: 2.0 Max TC CSI:0.070 Max BC CSI:0.017 Max Web CSI:0.023 VIEW Ver: 24.01.01A.0510.10 Job Number:TS2207 84 LUMBER Truss Label:KW2 Ply: 1 Qty:1 SEQN:120464 SY42 FROM: SC Cust: R 9462 JRef:1YaK94620001 T104 DrwNo:155.25.1735.21720 /BM 06/04/2025 3"8 3"8 1"8 23'2"8 1'8"8 1'4" (TYP) 5"4 22'6"4 3" 23'4" 7"8 7"8 1'9"4 1'1"12 23'1" 21'3"12 23'4" 3" 1'8" + A B I T V ABAN AO 1X3 1X3 3X3 3X3 W=3X4 W=3X4 2X4 1X3 $%Lbl:KW2?$ 06/04/2025 155 Harlem Ave North Building, 4th Floor Glenview, IL 60025 #%DETAIL?$ $%Lbl:STRBRIBR1014?$ 06/04/2025 155 Harlem Ave North Building, 4th Floor Glenview, IL 60025 #%DETAIL?$ $%Lbl:DEFLCAMB1014?$ 06/04/2025 84 L u m b e r 34 0 5 W i Ʃ C t . Gr a p e v i n e , T X Fi n a l F l o o r T r u s s L a y o u t Th e s e p l a c e m e n t p l a n s f o r t h e p r o d u c t s sp e c i f i e d w e r e b a s e d o n t h e i n f o r m a Ɵ o n pr o v i d e d t o u s . T h i s s e r v i c e i s s o l e l y in t e n d e d f o r p r o d u c t a p p l i c a Ɵ o n as s u r a n c e ; i t i s n o t i n t e n d e d t o c i r c u m v e n t th e n e e d f o r a d e s i g n p r o f e s s i o n a l a s de t e r m i n e d b y t h e b u i l d i n g c o d e s . T h e de s i g n e r o f r e c o r d a n d / o r b u i l d e r / f r a m e r is r e s p o n s i b l e t o a s s u r e t h e s e d r a w i n g s ar e c o m p a Ɵ b l e w i t h t h e o v e r a l l p r o j e c t . EsƟmator: -EsƟmator- Tracking: -Tracking- Sheet 1 of 1 Scale 1/4"=1'0" Tag Qty Product Len Cut Logic Header M3 3 1-3/4"x24" LVL 22'3x{1/22} Beam M1 5 1-3/4"x20" LVL 24'5x{1/24} M1 4 1-3/4"x20" LVL 22'4x{1/22} M1 3 1-3/4"x20" LVL 20'3x{1/19} M1 2 1-3/4"x20" LVL 16'2x{1/16} M2 2 1-3/4"x16" LVL 12'2x{1/11} Hanger H1 12 THA422 Simpson Strong Tie H2 1 EGQ5.50-SDS3 Hanger Simpson Strong Tie H4 1 HGUS412 Simpson Strong Tie H5 1 HUC412 Simpson Strong Tie TRUSS AND BEAM LAYOUT AND BEAM SIZES REVIEWED AND APPROVED BY JOHN MILLETT, PE TXPE 49558 FIRM #4391 JUNE 8, 2025