HomeMy WebLinkAboutSFRA2025-002639CROSSTOWN STRUCTURAL ENGINEERING HOME i FOUNDATION INSPECTION Date: August 22, 2025 Adam A. Green, P.E. (TT), MBA Austin I Dallas I Fort Worth I Houston I San Antonio I Waco (469) 751-7694 Attention: Ernando Teixera ( Subject: Load Bearing Wall post -repair evaluation 2715 Summer Wind Dr., Grapevine, TX To Whom It May Concern: «-"zv.CrosstoN%mEngineering.com Crosstown Engineering (CE) was retained to visually inspect the work completed on the subject Load Bearing Wall. We have determined the steel beam, supports and connections have been completed per our initial report and drawing dated 7/3/25. If you have any questions or need additional information, please call our office. Sincerely, Crosstown Land Development Services Texas Engineering Firm (F-15944) Adam Green, P.E., MBA Professional Engineer (TX #116597) 08/22/2025 �iE of r­%�,, ADM A,GREEN 116597 ,;4 1 of 2 CROSSTOWN STRUCTURAL ENGINEERING HOME A FOUNDATION INSPECTION DISCLOSURE & DISCLAIMER Adam A. Green, P.E. (TT), MBA Austin I Dallas I Fort Worth I Houston I San Antonio I Waco (469) 751-7694 «-"zv.CrosstoN%mEngineering.com NO WARRANTY IS EXPRESSED OR IMPLIED BY THIS ENGINEER AS TO THE PERFORMANCE OF THE BEAM OR THE REPAIRS THERETO. REPORT LLWrATIONS This report is written for informational purposes only. The opinions expressed in this report are based on a visual evaluation of current conditions observed at the time of the inspection. THERE IS NO WARRANTY, EXPRESSED OR IMPLIED, CONCERNING THIS ENGINEERING REPORT. The information in this report supersedes any verbal comments. expressed or implied, made by Crosstown Land Development Services or its principals, agents or employees. The client agrees that neither CLDS nor its employees or owners will be responsible for: 1. Knowledge of the subsurface conditions without extensive geotechnical data obtained from onsite drilling and test- ing of the recovered samples, 2. Knowledge of cracks, vertical differential displacement of floors without uncovering of the floor by the client; and 3. Any other element such as joists or beams and other structural members that is boxed or otherwise not readily available to CE for viewing, and releases CE from any liability attributable to such knowledge or conditions. Any prescribed repair or maintenance plan detailed by this report is based on observations of apparent performance of the facility at the time of this structural survey. Compliance with any code or specification other than as expressly noted is specifically excluded. This report was prepared expressly for the client and expressly for the purposes indicated by the client. Permission for use by any other person for any purpose, or by the client for different purpose is denied unless otherwise stated in writing by CE. CE SHALL HAVE NO LIABILITY FOR ACTS OR OMISSIONS BY THE CONTRACTOR OR HIS SUBCONTRAC- TORS PERFORMING WORK ON THIS PROJECT, OR THE FAILURE OF THE CONTRACTOR TO PERFORM THE WORK IN ACCORDANCE WITH THE REPAIR PLAN. CE IS NOT RESPONSIBLE FOR THE CONSTRUCTION MEANS, METHODS, TECHNIQUES, SEQUENCE OR PROCEDURES OR THE PRECAUTIONS INCIDENTAL THERETO. CE expressly DISCLAIMS ANY WARRANTY OF FITNESS FOR A PARTICULAR PURPOSE and the client expressly disclaims that it has contracted for or received any warranty of fitness for a particular purpose with respect to this report. THE REPORT UNDER THIS AGREEMENT IS THE OPINION OF CE AND THERE ARE NO WARRANTIES THAT EXTEND BEYOND THE DESCRIPTION ON THE FACE OF THIS AGREEMENT. 2of2 le CROSSTOWN STRUCTURAL ENGINEERING HOME a FOUNDATION INSPECTION Date: July 3, 2025 Austin I Dallas I Fort «V Attention: Emando Teixera ( Subject: Load Bearing Wall Evaluation 2715 Summer Wind Dr., Grapevine, TX Good Afternoon: :'edam A. Green. P.E. (TXI. MBA CITY OF GRAPEVINE THIS PAGE RELEASED FOR CONSTRUCTION RELEASE DOES NOT AUTHORIZE ANY WORK IN CONFLICT WITH THE BUILDING CODE OR ZONING ORDINANCE. CITY APPROVED PLANS TO BE KEPT ON THE JOB SITE AT ALL TIMES. 07/17/2025 BY: ARNOLDO RAMIREZ TSBPE: 1-3898 BUILDING INSPECTION DIVISION: RELEASE DOES NOT APPLY TO CONSTRUCTION IN EASEMENTS OR PUBLIC RIGHT OF WAY. ALL CHANGES MUST BE APPROVED. Crosstown Engineering (CE) was retained to inspect the subject load bearing wall and to provide an opinion. No other information was provided regarding prior engineering reports, recommendations for foundation repairs or construction documents relative to this structure. This report provides our reasonable professional opinion of the condition of the load bearing wall on the date of our inspection and does not take into consideration any changes in the condition of the load bearing wall after that date. Scove of Work Limitations: This report is for informational purposes only. The inspection excludes the detached buildings, privacy or retain- ing walls, general site drainage away from the structure, material and soil sampling/testing, and verification of concrete reinforcement or knowledge of the location of interior grade beams, boxed structural members not in plain sight or previous repair work. Removal of floor coverings or performance of invasive tests or procedures is not included. Document ReWei r: Documents were not provided for review. Analysis and Recommendations: Subject Item: PROVIDE SIGNED AND SEALED LETTER FROM REGISTERED ENGINEER CONFIRMING SITE INSPECTION AND APPROVAL OF STEEL BEAM WHEN WORK IS COMPLETE A field inspection was made to determine the beam required to replace the columns between the kitchen and living room in the first floor of the two-story, single family house. Discoveries: • The existing floor over the kitchen consists of 2x12 joists fastened into a glulam beam concealed in the attic. • The existing beam and columns can be replaced with a W10X22 x 22' Steel I -Beam, concealed in the attic. • The steel beam is to be supported by a minimum of 3.5" bearing length across the full width of the beam on the interior side and by a minimum of 5.5" bearing length across the width of the beam on the exterior end to support the notch at the top of the beam to fit under the roof decking. • The recommended beams have been designed in compliance with the 2021 IRC. • See attached drawings for more information. RECEIVED: 0710/2025 1 of 5 INSPECTOR TO VERIFY AT 25-002639 FRAMING INSPECTION 2715 SUMMER WIND DR INTERIOR ALTERATION le CROSSTOWN STRUCTURAL ENGINEERING HOME a FOUNDATION INSPECTION Disclaimer: Adam A. Green, P.E. (TX), MBA Austin I Dallas I Fort Worth I Houston I San Antonio I Waco (469) 751-7694 «sv. CrosstonnEngineering. com We do not warrant the future performance of the subject load bearing wall and the reader is urged to review the Disclosure & Disclaimer for other limitations and standard recommendations. The limit of liability is limited to the fee paid for this opinion. No further agreement shall be made, altered, or varied except by written instrument. Crosstown Engineering, its sub -contractors, and Adam Green, P.E., are not responsible for liability to the owner or others for acts or omissions of the contractor to carry out the repairs in accordance with their agreement or for the construction means, methods, techniques, sequences, procedures or the safety precautions incident thereto. The contractor is solely responsible for the warranty of the work they performed in accordance with their agree- ment. Sincerely, Crosstown Land Development Services Texas Engineering Firm (F-15944) Adam Green, P.E., MBA Professional Engineer (TX #116597) 7/3/2 PROVIDE SIGNED AND SEALED LETTER FROM REGISTERED ENGINEER CONFIRMING SITE INSPECTION AND APPROVAL OF STEEL BEAM WHEN WORK IS COMPLETE 1. GRAPYUNE CITY OF GRAPEVINE THIS PAGE RELEASED FOR CONSTRUCTION RELEASE DOES NOT AUTHORIZE ANY WORK IN CONFLICT WITH THE BUILDING CODE OR ZONING ORDINANCE CITY APPROVED PLANS TO BE KEPT ON THE JOB SITE AT ALL TIMES. 07/17/2025 BY: ARNOLDO RAMIREZ TSBPE: 1-3898 BUILDING INSPECTION DIVISION RELEASE DOES NOT APPLY TO CONSTRUCTION IN EASEMENTS OR PUBLIC RIGHT OF WAY. ALL CHANGES MUST BE APPROVED. 2 of 5 40 CROSSTOWN STRUCTURAL ENGINEERING HOME i FOUNDATION INSPECTION DISCLOSURE & DISCLAEMER Adam A. Green, P.E. (TX), MBA Austin I Dallas I Fort Worth I Houston I San Antonio I Waco (469) 751-7694 c«<z�•.Crosstonnl:. �. � _ '.. ;,com NO WARRANTY IS rxrr noSED OR IMPLIED BY THIS =4vu4r=x AS TO THE rrxrukMANCE OF THIS LOAD BEARING WALL OR THE REPAIRS THERETO. This report is written for informational purposes only. The opinions expressed in this report are based on a visual evaluation of current conditions observed at the time of the inspection. THERE IS NO WARRANTY, EXPRESSED OR IMPLIED, CONCERNING THIS ENGINEERING REPORT. The information in this report supersedes any verbal comments, expressed or implied, made by Crosstown Land Development Services or its principals, agents or employees. The client agrees that neither CLDS nor its employees or owners will be �-, , ...-Ale for: 1. Knowledge of the subsurface conditions without extensive geotechnical data obtained from onsite drilling and testing of samples, 2. Knowledge of cracks, vertical differential displacement of floors without uncovering of the floor by the client; and 3. Any other element such as joists or beams and other Structural... 1 that is boxed or otherwise not readily available to CE for viewing, and releases CE from any liability attributable to such knowledge or conditions. Any prescribed repair or maintenance plan detailed by this report is based on observations of apparent peril` ..... P: of the facility at the time of this structural survey. Compliance with any code or specification other than as expressly noted is specifically excluded. This report was prepared expressly for the client and expressly for the purposes indicated by the client. Permission for use by any other person for any purpose, or by the client for different purpose is denied unless otherwise stated in writing by CE. We recommend that the owner contact Crosstown to perform an inspection of the installations prior to drywall being placed on the wall to ensure that the I is completed properly. CE SHALL HAVE NO LIABILITY FOR ACTS OR O1Vuo6iL%ji4b BY THE CONTRACTOR OR HIS SUBCONTRAC- TORS PERFORMING WORK ON THIS PROJECT, OR THE FAILURE OF THE CONTRACTOR TO PERFORM THE WORK IN ACCORDANCE WITH THE REPAIR PLAN. CE IS NOT RESPONSIBLE FOR THE CONSTRUCTION MEANS, M=inuLS, TECHNIQUES, SEQUENCE OR PROCEDURES OR THE PRECAUTIONS INCIDENTAL 1 r1n1z 10. CE expressly DISCLAIMS ANY WARRANTY OF FITNESS FOR A PARTICULAR PURPOSE and the client expressly disclaims that it has contracted for or received any warranty of fitness for a particular purpose with respect to this report. THE REPORT UNDER THIS AGREEMENT IS THE OPINION OF CE AND THERE ARE NO WARRANTIES THAT EXTEND BEYOND THE DESCRIPTION ON THE FACE OF THIS AGREEMENT. 3of5 0 M -0 z m 5 0 z 0 O 'v 3 r -n D z 0 s m = o N � N ;LJ A C D rri r3 ------ (1) r cp — D O N 7 1 o. O O line of second floor � J � A m o CD � O m p m r 3 r m _ C � m n C 0 z o r Z cn z N 0 N 2 n 0 0 0 y rr T 7 CD N _ O_ CD fA n A nt 0 ~ i= o a — o 2 ...Ili_■...lt_1..�L■ � ■ � ■ ■ ■ � ■ _ ■ � I of second floor W1 OX22 x 22' Steel I -Beam 000 CD CD in rm0 o c 3 m N -'7IA iD Zm o a �� z 0 o. s o 44 / tE 5 A!!MA GREEN p `597 S 0703'25 joi, <rcENSEpV*p s,�ONAt F. r Crosstown Engineering Texas Engineering Firm (F-15944) 6119 Greenville Ave, Ste 320 Dallas. TX 75206 CROSSTOWN[ CROSSTOWNEh'GfNEERING BCE FlRM %-�SY4 - vnaw TONIENGINEEiHC D>w :M4�•51-7041 DALLAS%ErROPIE% PROVIDE SIGNED AND SEALED LETTER FROM REGISTERED ENGINEER CONFIRM[ G SITE INSPECTION AND APPROVAL OF STEEL BEAM WHEN WORK IS COMPLETE 2715 SU ER WIND DR. SHEET IOF2 GRAPEVINE, T� � ' (9FNFRAI NOT", t,1 N 'Ai. I i!I1 I" I'II I n W Rn Y AI I MFA11111I 1.11_N `i PI IOR TO OROERNO OR CUTTING MATERIAL. JOISTS INl1 RStQTI DSYNIIWII IISHSFAMSARi II.1IA:TFNF0TOBFAMSWIIN SIMPSON HUSTYPF HANOFRSOR FOUNALFNT - FASTEN TRIPLE LVL INTO DOUBLE LVL WITH SIMPSON HU412 MANGER O + O 0 Il0 Q*1 O 1 \ THROUGH -BOLT AT WOOD FILLER STAGGERED 24" 3.5" COILED STRAPS ON CENTER 16" LENGTH TO STRAP BEAM TO SUPPORTS BELOW STFF� RFA�0 s1nr- )oc:w CD W W iuUQLA. DO0O WU�U _jWavn V/ Z Q O zZQ� Qw z z z�w F-3: Ncn(L \ w FD cn w W z m 9 W J F- W N H 2X RAFTER a U / COILED STRAPS 12" LENGTH 48" ON CENTER TO STRAP WALL TO SIDE OF BEAM a r+A•1 CROSS SECTION VIEW OF BEAM NOTCH BEAM TO FIT ""'DER ROOF DECKING 0 0 0 �'• W y ICI W ff 1U O� 1G�y1 i';< IPir ♦�� � 10 W:� — N a,. oo € n COILED STRAPS 5.5" min 16" LENGTH TO STRAP BEAM TO o ? c7 SUPPUR I S BELOW e s N 0 N W� o: 0 z �x W LLj 2z j W Ln Q CV 0 0 u 2W� If z O N O V CROSSTOWN STRUCTURAL ENGINEERING HOME a FOUNDATION INSPECTION Date: July 3, 2025 Adam A. Green, P.E. (TX), MBA Austin I Dallas I Fort Worth I Houston I San Antonio I Waco (469) 751-7694 Attention: Emando Teixera ( Subject: Load Bearing Wall Evaluation 2715 Summer Wind Dr., Grapevine, TX Good Afternoon: Nm-%v.CrosstoN nF.ngineering.com Crosstown Engineering (CE) was retained to inspect the subject load bearing wall and to provide an opinion. No other information was provided regarding prior engineering reports, recommendations for foundation repairs or construction documents relative to this structure. This report provides our reasonable professional opinion of the condition of the load bearing wall on the date of our inspection and does not take into consideration any changes in the condition of the load bearing wall after that date. Scope of Work Limitations: This report is for informational purposes only. The inspection excludes the detached buildings, privacy or retain- ing walls, general site drainage away from the structure, material and soil sampling/testing, and verification of concrete reinforcement or knowledge of the location of interior grade beams, boxed structural members not in plain sight or previous repair work. Removal of floor coverings or performance of invasive tests or procedures is not included. Document Reriei r: Documents were not provided for review. Analysis and Recommendations: Subject Item: A field inspection was made to determine the beam required to replace the columns between the kitchen and living room in the first floor of the two-story, single family house. Discoveries: • The existing floor over the kitchen consists of 2x12 joists fastened into a glulam beam concealed in the attic. • The existing beam and columns can be replaced with a W10X22 x 22' Steel I -Beam, concealed in the attic. • The steel beam is to be supported by a minimum of 3.5" bearing length across the full width of the beam on the interior side and by a minimum of 5.5" bearing length across the width of the beam on the exterior end to support the notch at the top of the beam to fit under the roof decking. • The recommended beams have been designed in compliance with the 2021 IRC. • See attached drawings for more information. 1 of 5 40 CROSSTOWN STRUCTURAL ENGINEERING HOME i FOUNDATION INSPECT)ON Disclaimer: Adam A. Green, P.E. (TX), MBA Austin I Dallas I Fort Worth I Houston I San Antonio I Waco (469) 751-7694 c«i-%v. CrosstoT<nEngineering. com We do not warrant the future performance of the subject load bearing wall and the reader is urged to review the Disclosure & Disclaimer for other limitations and standard recommendations. The limit of liability is limited to the fee paid for this opinion. No further agreement shall be made, altered, or varied except by written instrument. Crosstown Engineering, its sub -contractors, and Adam Green, P.E., are not responsible for liability to the owner or others for acts or omissions of the contractor to carry out the repairs in accordance with their agreement or for the construction means, methods, techniques, sequences, procedures or the safety precautions incident thereto. The contractor is solely responsible for the warranty of the work they performed in accordance with their agree- ment. Sincerely, Crosstown Land Development Services Texas Engineering Firm (F-15944) Adam Green, P.E., MBA Professional Engineer (TX #116597) 7/3/2025 of rFk�slll ADAM A. GREEN ................... . ' q 116597 111 Cc 4!CENS"� S115 NAI E?_ 2of5 40 CROSSTOWN STRUCTURAL ENGINEERING HOME i FOUNDATION INSPECTION DISCLOSURE & DISCLAEMER Adam A. Green, P.E. (TX), MBA Austin I Dallas I Fort Worth I Houston I San Antonio I Waco (469) 751-7694 «sv. CrosstonnEngineering. com NO WARRANTY IS EXPRESSED OR IMPLIED BY THIS ENGINEER AS TO THE PERFORMANCE OF THIS LOAD BEARING WALL OR THE REPAIRS THERETO. This report is written for informational purposes only. The opinions expressed in this report are based on a visual evaluation of current conditions observed at the time of the inspection. THERE IS NO WARRANTY, EXPRESSED OR IMPLIED, CONCERNING THIS ENGINEERING REPORT. The information in this report supersedes any verbal comments, expressed or implied, made by Crosstown Land Development Services or its principals, agents or employees. The client agrees that neither CLDS nor its employees or owners will be responsible for: 1. Knowledge of the subsurface conditions without extensive geotechnical data obtained from onsite drilling and testing of the recovered samples, 2. Knowledge of cracks, vertical differential displacement of floors without uncovering of the floor by the client; and 3. Any other element such as joists or beams and other structural members that is boxed or otherwise not readily available to CE for viewing, and releases CE from any liability attributable to such knowledge or conditions. Any prescribed repair or maintenance plan detailed by this report is based on observations of apparent performance of the facility at the time of this structural survey. Compliance with any code or specification other than as expressly noted is specifically excluded. This report was prepared expressly for the client and expressly for the purposes indicated by the client. Permission for use by any other person for any purpose, or by the client for different purpose is denied unless otherwise stated in writing by CE. We recommend that the owner contact Crosstown to perform an inspection of the installations prior to drywall being placed on the wall to ensure that the improvement is completed properly. CE SHALL HAVE NO LIABILITY FOR ACTS OR OMISSIONS BY THE CONTRACTOR OR HIS SUBCONTRAC- TORS PERFORMING WORK ON THIS PROJECT, OR THE FAILURE OF THE CONTRACTOR TO PERFORM THE WORK IN ACCORDANCE WITH THE REPAIR PLAN. CE IS NOT RESPONSIBLE FOR THE CONSTRUCTION MEANS, METHODS, TECHNIQUES, SEQUENCE OR PROCEDURES OR THE PRECAUTIONS INCIDENTAL THERETO. CE expressly DISCLAIMS ANY WARRANTY OF FITNESS FOR A PARTICULAR PURPOSE and the client expressly disclaims that it has contracted for or received any warranty of fitness for a particular purpose with respect to this report. THE REPORT UNDER THIS AGREEMENT IS THE OPINION OF CE AND THERE ARE NO WARRANTIES THAT EXTEND BEYOND THE DESCRIPTION ON THE FACE OF THIS AGREEMENT. 3of5 KEEP THIS COLUMN BFAST DEMOLISH COLUMNS, TYPICAL line of second floor KITCHEN g DEMOLISH `- c WALLS `o line of second floor ADD 6" • TO EXTEND BFAST I ' COLUMN ■ E 0) d �m !�� ! U) ' N ■ N LIVING ' x vaulted ceiling N ■ ' O line of second .......—.. floor 3 ....... �KiTcHem I g3.5" Bearing R Length Required �o 1 pimn1 ITlnN, PI AN, line of second floor S$ t W N ut vo C me a,g V 4 G S vaulted ceiling PROPORrn RF A AA pi A No _ DESIGNED IN COMPLIANCE WITH 2O21 IRC. MrAnrarl! ti/ M VMIMI nrnr r•:rw n.n rwrww w++.v n+ra. CROSS SECTION VIEW OF BEAM I i 2X RAFTER NOTCH BEAM TO FIT I INDER ROOF DECKING 0 0 IL 0 QIL 0 0 O \ i W fF: i s�yDIo�z'� o Lh THROUGH -BOLT '' ea _ € COILED STRAPS " AT WOOD FILLER v v a 12" LENGTH 3.5" COILED STRAPS STAGGERED 24" 48" ON CENTER 5.5° min COILED STRAPS 16" LENGTH TO ON CENTER TO STRAP WALL 16" LENGTH TO N 3 STRAP BEAM TO TO SIDE OF STRAP BEAM TO SUPPORTS BEAM SUPPUK I S BELOW BELOW STFF� RFA�0 slnF )oc:w AFMF:ABI M(TTrA. CONTRACTOR TO FIELD VERIFY ALL MEASUREMENTS PRIOR TO ORDEFONG OR CUTTING MATERIAL. JOISTS INTERSECTED BY NF W FLUSH BEAMS ARE TO FASTENED TO BFAMS WITH SIMPSON HUB TYPE HANOFRS OR FOUIVALFNT - FASTEN TRIPLE LVL INTO DOUBLE LVL WITH SIMPSON HW12 HANGER DFW Wall Removal, LLC 2828 E Trinity Mills Rd, Floor 1 Trinity Square Plaza Carrollton, TX 75006 www.dfwwallremoval.com July 04, 2025 To: City of Grapevine Building Department Re: Permit Authorization for Wall Removal at 2715 Summer Wind Dr, Grapevine, TX 76051 To Whom It May Concern, This letter is to formally authorize our client. Jim Manning, to apply for and obtain all necessary permits from the City of Grapevine related solely to the wall removal portion of the residential project located at 2715 Summer Wind Dr, Grapevine, TX 76051. DFW Wall Removal, LLC, under the ownership of Ernando Teixeira, will be exclusively responsible for performing the wall removal scope only. No other construction. finish -out, or remodeling services will be provided by our company under this permit. Should you require any further information or clarification, please do not hesitate to contact us. Sincerely, Ernando Teixeira Owner, DFW Wall Removal, LLC