Loading...
HomeMy WebLinkAboutSFRA2025-002086ALL CHANGES REQUIRE APPROVAL OF REVISED PLANS APPROVED PLANS SHALL BE KEPT ON JOBSITE AT ALL TIMES SEPERATE PLUMBING, MECHANICAL, ELECTRICAL AND SIGN PERMITS SHALL BE REQUIRED. CONSTRUCTION HOURS 7:00 A.M. - 7:00 P.M. MONDAY - SATURDAY ONLY NO WORK PERMITTED ON SUNDAY w 91 EXISTING SITE PLAN SALE :1/3" a I'-0" POST TO BEAM CONNECTION SHALL BE BOLTED OR A MECHANICAL APPROVED METHOD LOT LOT 3 4 S 89 54'20" E 65.20' 8'4- \ I}, 16$' 14'2' Ln 0 0 LOT 27 LOT TWO STORY ? 28 BR,CK AND 3 �p FRAME.^ M ryT ri !" 7'4- r.{ O C3 e O O Ivi' o O Z n In {� N 89 58'20" W _ - W —WAM M65.20' �— REA..i_ STM OMN MAN HOLE, POST OAK ROAD *SIDE BEAM WITHOUT POST MUST BE LOAD BEARING TO THE FOUNDATION* LOT 5 LOT 26 u Q N 0 a � � 0 Ln oc z 4 CONTRACTOR SHALL CALL FOR INSPECTIONS: (817) 410-3010 CONTRACTOR REGISTRATION WILL BE REVOKED UPON PERMIT EXPIRATION. 2 g z N CITY OF GRAPEVINE .xu THIS PAGE RELEASED FOR CONSTRUCTION RELEASE DOES NOT AUTHORIZE ANY WORK IN CONFLICT WITH THE BUILDING CODE OR ZONING ORDINANCE. CRY APPROVED PLANS TO BE KEPT ON THE JOB SITE AT A, I TVFc 08/01/2025 .. BY: ARNOLDO RAMIREZ TSBPE: 1-3898 BUILDING INSPECTION DIVISION. RELEASE DOES NOT APPLY TO CONSTRUCTION IN EASEMENTS OR PUBLIC RIGHT OF WAY. T—I aALL CHANGES MUST 8E APPROVED. WIT CITY OF GRAPEVINE THIS PAGE RELEASED FOR CONSTRUCTION RELEASE DOES NOT AUTHORIZE ANY WORK IN CONFLICT IAITH THE BUILDING CODE OR ZONING ORDINANCE CITY APPROVED PLANS TO BE KEPT ON THE JOB SITE AT ALL TIMES. OS/01/2025 BY: ARNOLDO RAMIREZ TSBPE: 1-3898 BUILDING INSPECTION DIVISION: RELEASE DOES NOT APPLY TO CONSTRUCTION IN EASEMENTS OR PUBLIC RIGHT OF WAY. ALL CHANGES MUST BE APPROVED. 8 Q PROPOSED SITE PLAN sulF:>Vs•�ro� LOT LOT 4 LOT 3 5 S 89 54'20" E 65.20' SO co ----------I .� 34' Cr i ' � a.4x • � � 'bean• � i 18`6^ 0 9,4., c LOT vi 2% LOT 28 W TWO STORY bi BRIOC AND ` 3 LOT (p FRAME. lD 26 n m r1 r4• H o c� 16�L" : •• z ....... N 89 58'20".w . MF1ER. ! STM MAIN MAIN HOLE. POST OAK ROAD Y 1O____ 1"- V) d00 0 oN0 Ln w A -A EXTERIOR PERIMETER BEAM - 3-5/8- Kw WT a16' O.C.O.W. CONCRETE OVER 10 MIL POLY VAPOR BARRIER UK 6' PAD OF COMPACTED SELECT Flu E9STM SOL (13) STIRRUPS -3/4' 114) REBARS 2 TOP / 2 BOTTOM D-D INTERIOR BEAM F-- 3-5/8' KW MAT O.C. O16' B.W. CONCRETE OVER 10 MIL 11 I. VAPOR BARRIER •'I�.IIFi ;'_I IF={► MIN. 6' PM OF COMPACTED SELECT FILL 11�i1f. ii,'�:n E%ISTMC sole. STmwPs e3a D.C. —4-3/4" (/6) RESARS 2 TOP / 2 BOTTM &I11l:1:l=F_\�,KTA1119:KIIIjil413i►`,LIP39:1=1 LOAD BEARING TO THE FOUNDATION* E< :�. umT 4"SLAB-ON-GRADE CONIC, MIN 300D PSI 10717 OVER COMPACTED BASE @ 95% 2%ABOVE OMC REINF. No 3 Bars @ 16" O.C. Both Sides ■rrr.r.r.• O� 1s rrrrrr■.rrrr■ � ■ :.;,�. ■ ■ ■ p � • C1 a • 16-0"X16'-0" 16'-0' 22'-0" PA110 CIVER. of p ��T07 CO ETE. V ■ PATP ° ADDITION. a ; r • ■ ■ � p � a 7r■r.r•.rr..rrrrr.rrry ■ c ° q ■ 0. >' NEW ° a p CONCRETE. - 1 C 1 G 11 81411 ■ V $ N .y LOT FOUNDATION PLAN SCALE :1/2' = V-0" CITY OF GRAPEVINE THIS PAGE RELEASED FOR CONSTRUCTION RELEASE DOES NOT AUTHORIZE ANY WORK IN CONFLICT WITH THE BUILDING CODE OR ZONING ORDINANCE. CITY APPROVED PLANS TO BE KEPT ON THE JOB SITE AT ALL TIMES. OS/0112025 BY: ARNOLDO RAMIREZ TSBPE: 1-3898 BUILDING INSPECTION DIVISION: RELEASE DOES NOT APPLY TO CONSTRUCTION IN EASEMENTS OR PUBLIC RIGHT OF WAY. Y Q 0 V) 0-0 W Q Ln = z 5 z O_ F Q z 0 LL ALL CHANGES MUST BE APPROVED. III-I�L!II�II EXISTING HOUSE. 1 POST TO BEAM CONNECTION SHALL BE BOLTED OR A MECHANICAL APPROVED METHOD EXISTING HOUSE. I EXTERIOR ELEVATION : FRONT sm; vr.ra• 3MNGLE Kuut- I -LT.mr.- — EXTERIOR ELEVATION: LEFT swsvr.ra *SIDE BEAM WITHOUT POST MUST BE LOAD BEARING TO THE FOUNDATION* b E]ImICf F. I[3717 Y Q O N 0- 0 r,4 O t Ln = --] - L I - I L 1 1 - ' I - ' ' Q EXTERIOR ELEVATION : RIGHT U) z W ..J W cc ,c r �� CITY OF GRAPEVINE THIS PAGE RELEASED FOR CONSTRUCTION RELEASE DOES NOT AUTHORIZE ANY WORK IN CONFLICT WITH THE BUILDING CODE OR ZONING ORDINANCE CITY APPROVED PLANS TO BE KEPT ON THE JOB SITE AT ALL TIMES. 08/012025 BY: ARNOLDO RAMIREZ TSBPE: 1-3898 BUILDING INSPECTION DIVISION. RELEASE DOES NOT APPLY TO CONSTRUCTION IN EASEMENTS OR PUBLIC RIGHT OF WAY. ALL CHANGES MUST BE APPROVED. 1L tGRA 1i\E CITY OF GRAPEVINE THIS PAGE RELEASED FOR CONSTRUCTION RELEASE DOES NOT AUTHORIZE ANY WORK IN CONFLICT WITH THE BUILDING CODE OR ZONING ORDINANCE. CITY APPROVED PLANS TO BE KEPT ON THE JOB SITE AT ALL nMEs. 08l01/2025 BY: ARNOLDO RAMIREZTSBPE: 1-3898 BUILDING INSPECTION DIVISION: RELEASE DOES NOT APPLY TO CONSTRUCTION IN EASEMENTS OR PUBLIC RIGHT OF WAY. ALL CHANGES MUST BE APPROVE POST TO BEAM CONNECTION SHALL BE BOLTED OR A MECHANICAL APPROVED METHOD RAFTER BRACING DETAIL SCALE Vrzi-T #3 DOWEL BA:. 1 IM 24" O C. ALL SLABS SHALL BE REINFO WITH #3 REBAR Q 18" O.C. EACH WA COVERED WITH ZOF CONCRETE NEW SLAB 8• EXISTING SLAB 8 BEAM � b EXISTING COMPACTED SEII----+ f SLAB DETAIL SCALE Oman NOTE: ill A PROVIDE SIMPSON H2 5A OEVERY'° RAFTER TO BEAM 8 2 SIMPSON LSTA STRAPS Q EACH COLUMN TO BEAM ROOF SHINGLES 2X6 ROOF RAFTER 1/2' CDX SHEATHING W/ 15# BELT 2X6 ROOF RAFTERS 2X6 COLLAR TIE ® 16- METAL DRIP ECGE 112 TRIM \ 1X FASCiA SEE ELEV, 3/8' PLYWOOD SOFFIT SEE BEAM PLAN SIMPSON BEAM HEADER 8X8 TREATED COLUMN r-o' b ti 0 COLUMN FOOTER PLAN SCALE ,n. 4 8X8TREATED COLUMN (2) 04 BARS EACH N WAY (TCPIBOTTOM; CONCRETE 3000 PS. ~ I 7-0' 4 TYPICAL SECTION 2 8X8TREATED COLUMN �DTYPICAL SECTION 1 SCALE yr-r-o oil /?/ (//7 s, o' v, 6"" i *SIDE BEAM WITHOUT POST MUST BE LOAD BEARING TO THE FOUNDATION* i I (Y) Y, Y i v i i l 4' II i POST TO BEAM CONNECTION SHALL BE BOLTED OR A MECHANICAL APPROVED METHOD 1 r ,fE/ir+ wili. rer ova i � cF TO 'TOP ?L64TiL itaFTQC, ASnomr—i ,✓ALL wwc polo 1i0 z r!!✓�i✓LE OCAIS,T" wn�� •'I �V I i 1 CITY OF GRAPEVINE THIS PAGE RELEASED FOR CONSTRUCTION RELEASE DOES NOT AUTHORIZE /NYWORK IN CONFLICT VATH THE BUILDING CODE OR ZONING ORDINANCE. CITY APPROVED PLANS TO BE KEPT ON THE JOB SITE AT ALL TIMES, 08/01/2025 BY: ARNOLDO RAMIREZ TSBPE: 1.3898 BUILDING INSPECTION DIVISION. RELEASE DOES NOTAPPLY TO CONSTRUCTION IN EASEMENTS OR PUBUC RIGHT OF WAY, ALL CHANGES MUST BE APPROVED. n 55-1 1-131pce-s 9-y f.R:1 1�E CITY OF GRAPEVINE THIS PAGE RELEASED FOR CONSTRUCTION ISLE ASE DOES NOT AUTHOR ZE ANY WORK IN CONFLICT VMTH THE BULDING CODE OR ZONI N"., ORDINANCE. CITY APPROVED PLANS TO BE KEPT ON THE JOB SITE AT ALL TIMES. 08/01/2025 13Y: ARNDLDO RAMIREZ TSEIPE: 1.3898 BUILDING INSPECTION DIVISION. RELEASE DOES NOT APPLY TO CONSTRUCTION IN EASEMENTS OR PUBLIC RIGHT OF WAY. ALL CHANGES MUST BE APPROVED. 1'SIAS ON GRAD! CONC MIN KIM PSI le OVER COMPACTED BASE P 9SV. 1%ABOVE OAEC 0 REINS No S Mn B Iw 0 C. Both SIM a A -A MRIDA P RnMMR WW Q .r r fV 0 .'•.a�il.is� ............................... 1!1 OC as.•eo en ti i �i ' — t ■..' n• tam.. V . 16'-0"X16 -T 16'-0"X22 -0' It — PATIO COVER O ! CONCRETE, i • I I' PATIQ • ADDITION. ! � a • 3, . •i w r � i • ■�� y M raM - - NEW CONCRETE. 16'6" 81411 l� i....................................AC1.� i� 0 LOT 1 FOUNDATION PLAN E E1Qg1 PLAN FOUNDATION v9' • I a m Q ('BRA V)E #0) CITY OF GRAPEMNE THS PAGE RELEASED FOR CONSTRUCTION IELEASE DOES NOT AUTHORIZE ANY WOW IN CONFLICT WTHTFE BUILDING CODE OR ZONING ORDINANCE. CRY APPROVED PLANS TO BE IEPT ON THE JOB SITE AT ALL TIMES, O8101I2025 BY: ARNOLDO RAMIREZ TSBPE: 1.3898 BUILDING INSPECTION DIVISION: RELEASE DOES NOT APPLY TO CONSTRUCTION IN EASEMENTS OR PUBLIC RIGHT OF WAY. ALL CHANGES MUST BE APPROVED. *SIDE BEAM WITHOUT POST MUST BE LOAD BEARING TO THE FOUNDATION* /$,EAW Rw �T-O fI i lj i I Nr� 'r )/ P �L CITY OF GRAPEVINE THS PAGE RELEASED FOR CONSTRUCTION FE LEASE DOES NOT AUTHORIZE ANY WOKS IN CON-UCT VIA TH THE BUILDING CODE OR ZONNG ORDI NNIL E. CITY APPROVED PLANS TO BE KEPT ON TIE JOB SITE AT ALL TIMES. 08101/2025 BY: ARNOLDO RAMIREZ TSBPE: 1.3888 BUILDING INSPECTION DIVISION: RELEASE DOES NOT APPLY TO CONSTRUCTION IN EASEMENTS OR PUBLIC RIGHT OF WAY, ALL CHANGES MUST BE APPROVED. *SIDE BEAM WITHOUT POST MUST BE LOAD BEARING TO THE FOUNDATION* c S �ATo CoviE4 s�tE iS /G )C /G 1� a y CITY OF GRAPEVINE THIS PAGE RELEASED FOR CONSTRUCTION RELEASE DOES ND AUTHOR ZE ANY WORK IN CONFLICT VATH THE BULDING CODE OR ZONING ORDINANCE. CITY APPROVED PLANS TO BE KEPT ON THE JOB SITE AT ALL TIRES. 08/01/2025 I BY: ARNOLDO RAMIREZ TSBPE: 1.3898 BUILDING INSPECTION DIVISION - RELEASE DOES NOT APPLY TO CONSTRUCTION IN EASEMENTS OR PUBLIC RIGHT OF WAY. ALL CHANGES MUST BE APPROVED. FRAMING INSPECTION REQUIRED AT BEAM TO RESIDENCE CONNECTION AND LEDGER BOARDS ?X8 !R fwF b , wA�L c.riTN Y s RK sco �? ) s« ewr Pa s b foci i ' I �I Ij i *SIDE BEAM WITHOUT POST MUST BE POST TO BEAM CONNECTION LOAD BEARING TO THE FOUNDATION* SHALL BE BOLTED OR A MECHANICAL APPROVED METHOD .io /3X,Qm wal SST or TP aF ,F>ts%NG r5 - D OCR%E w ALL Cf SCR k wE o ., r?a 'or p�9TE w.7i� � `�GRc. SreEKr1' 0 A *SIDE BEAM WITHOUT POST MUST BE LOAD BEARING TO THE FOUNDATION* Lg-r-T sloz u x ,,f FRAMING INSPECTION REQUIRED AT BEAM TO RESIDENCE CONNECTION I!ZALvL �rflG� d LvL RAM F—� �t8 4CQA7 a c QO s-t Q %PF\ PIF CITY OF GRAPEVINE THS PAGE RELEASED FOR CONSTRUCTION RELEASE DOES NOT AUTHORIZE ANYWOW IN COWUCT WTHTI-E BUILDING CODE OR ZONING ORDINANCE. CRY APPROVED PLANS TO BE KEPT ON TIE JOB SITE AT ALL TIRES. 08f0112025 BY: ARNOLDO RAMIREZ TSBPE: 1.3898 BUILDING INSPECTION DIVISION RELEASE DOES NOT APPLY TO CONSTRUCTION IN EASEMENTS OR PUBLIC RIGHT OF WAY ALL CRINGES MUST BE APPROVED. POST TO BEAM CONNECTION SHALL BE BOLTED OR A MECHANICAL APPROVED METHOD r i • F,�r�r�N� 3 3 3 3 3 3 y 3 3 1 3 � 3 3 3 3 V- 2 1 KEY N oT4.s 1 ; 1-1 - Lvl SEAtAS 2 = SrxB c><owe. Poc-rS 3 2X & RAFTEes ycelo-1 if"o-C CITY OF GRAPEVINE THS PAGE RELEASED FOR CONSTRUCTION RELEASE DOES NOT AUTHORIZE ANYWDW IN CONFLICT VNTHTHE BUILDING CODE OR ZONING ORDINWCE. ALL TIMES. 0810112025 BY: ARNOLDO RAMIREZ TSBPE: 1.3898 BUILDING INSPECTION DIVISION RELEASE DOES NOT APPLY TO CONSTRUCTION IN EASEMENTS OR PUBLIC RIGHT OF WAY. ALL CFIANGES MUST BE APPRDVED.