Loading...
HomeMy WebLinkAboutSFRA2025-002685JOB ADDRESS: AIJG o 6 w; RECEIVED: 07/11/2025 DATE OF ISSUANCE: 25-002685 1805 QUAIL HOLLOW DR 25-002685 SOLAR PANEL INSTALL PERMIT #: BUILDING PERMIT APPLICATION ELECTRONIC REVIEW (PLEASE PRINT LEGIBLY - COMPLETE ENTIRE FORM) 1805 Quail Hollow Dr. Grapevine TX 76051 SUITE # LOT: BLOCK: SUBDIVISION: BUILDING CONTRACTOR (company name): SunSolar Solutions CURRENT MAILING ADDRESS: 8932 W Cactus Rd CITY/STATE/ZIP: Phoenix, AZ 85381 pH: # 607-773-6675 Fax # PROPERTY OWNER: Pelagio Del Mar CURRENT MAILING ADDRESS: 1805 Quail Hollow Dr. CITY/STATE/ZIP: Grapevine, TX 76051 PHONE NUMBER: 817-368-6337 PROJECT VALUE: $ 13,737.00 FIRE SPRINKLERED? YES NO WHAT TRADES WILL BE NEEDED? (Check ones that apply) ELECTRIC X PLUMBING MECHANICAL DESCRIPTION OF WORK TO BE DONE: Installation of a 4.150 kW rooftop mounted photovoltaic system. USE OF BUILDING OR STRUCTURE: NAME OF BUSINESS: SunSolar Solutions Total Square Footage under roof: Square Footage of alteration/addition: [� I hereby certify that plans have been reviewed and the building will be inspected by a certified energy code inspector in accordance with State Law. Plan review and inspection documentation shalt be made available to the Building Department (required for new buildings, alterations and additions) ❑ I hereby certify that plans have been submitted to the Texas Department of Licensing and Regulation for Accessibility Review. Control Number: (Not required for I & 2 family dwellings) f I hereby certify that an asbestos survey has been conducted for this structure in accordance with the regulatory requirements of the Texas Department of Health. (REQUIRED FOR DEMOLITIONS, ADDITIONS AND OR ALTERATION TO COMMERCIAL AND PUBLIC BUILDINGS) I hereby certify that the foregoing is correct to the best of my knowledge and all work will be performed according to the documents approved by the Building Department and in compliance with the City Of Grapevine Ordinance regulating construction. It is understood that the issuance of this permit does not grant or authorize any violation of any code or ordinance of the City Of Grapevine. I FURTHERMORE UNDERSTAND THAT PLANS AND SPECIFICATIONS ARE NOT REVIEWED FOR HANDICAPPED ACCESSIBILITY BY THE CITY, AND THAT THE DESIGN PROFESSIONAL/OWNER IS RESPONSIBLE FOR OBTAINING SUCH APPROVAL FROM THE APPROPRIATE STATE AND OR FEDERAL AGENCY(S). ��A PRINT NAME: Kassie Perez SIGNATURE 7slarsolutions. ® CHECK BOX IF PREFERRED TO BE CONTACTED BY E-MAIL THE FOLLOWING IS TO BE COMPLETED BY THE BUILDING INSPECTION DEPARTMENT Construction Type: B Permit \ aluation: `5 Setbacks Approval to Issue Occupancy Group:- 3 Fire Sprinkler: YES NO Front: Electrical ►� Division: Building Depth: Zoning: Q`- Sy Building Width: Occupancy Load: _ --Lc4rease Trap Plan Review Approval: /j ate: 4! Site Plan Approval: Date: Fire Department: Date: Public Works Department: Date: Health Department: Date: Approved for Permit: Date: Lot Drainage Submitted: Approved: P.O. BOX 95104, GRAPEVINE, TX 76099 (817) 410-3165 Left: Rear: Right: Building Permit Fee: Plan Review Fee: Lot Drainage Fee: Sewer Availability Rate: Water Availability Rate: Total Fees: Plumbing X Mechanical �{ Hood X Total Amount Due: 150.00 O:FORMS\DSPERMITAPPLICATIONS 1/0-Rev.11/04,5J06,2/07,1 /09,4/1 19 City of Grapevine Building - Residential PO Box 95104 Alteration Grapevine, Texas 76099 817) 410-3166 Project # 25-002685 Project Description: Installation of a 4.150 kW rooftop mounted photovoltaic system. [ELECTRONIC REVIEW] Issued on: 08/06/2025 at 11:36 AM ADDRESS INSPECTIONS 1 1805 Quail Hollow Dr. Grapevine, TX 76051 1. Building Final LEGAL INFORMATION FIELDS Hunters Ridge Addition- "APPLICANT NAME (Individual) Kassie Perez Gpv Blk 7 Lot 6 S 'APPLICANT PHONE NUMBER 602-609-6680 APPLICANT E-MAIL PERMIT HOLDER Brian Fennemore VALUATION 13737.00 Sunsolar Solutions Square Footage 3030 (602) 773-6675 * CONSTRUCTION TYPE VB COLLABORATORS " OCCUPANCY GROUP R-3 • Brian Fennemore DOCUMENTS - MISC 01 Grapevine Application.pdf Sunsolar Solutions PELAGIO DEL MAR SND250445_25- (602) 773-6675 DOCUMENTS MISC 02 04037_Structural_Plans_Stamped.pdf PELAGIO DEL MAR SND250445 25- OWNERS DOCUMENTS - MISC 03 04037_Calcs_Stam ped. pdf • Mar, Pelagio M Del PELAGIO DEL MAR SND250445 25- DOCUMENTS MISC 04 04037_Cert Letter_Stamped.pdf ZONING DISTRICT R-5.0 FEE TOTAL PAID DUE Building Permit Fee, ($150.00 Flat Fee) Simple Alteration $ 150.00 $ 150.00 $ 150.00 TOTALS $ 150.00 $ 150.00 $ 0.00 READ AND SIGN I HEREBY CERTIFY THAT THE FOREGOING IS CORRECT TO THE BEST OF MY KNOWLEDGE AND ALL WORK WILL BE PERFORMED ACCORDING TO THE DOCUMENTS APPROVED BY THE BUILDING DEPARTMENT AND IN COMPLIANCE WITH THE CITY OF GRAPEVINE ORDINANCE REGULATING CONSTRUCTION. IT IS UNDERSTOOD THAT THE ISSUANCE OF THIS PERMIT DOES NOT GRANT OR AUTHORIZE ANY VIOLATION OF ANY CODE OR ORDINANCE OF THE CITY OF GRAPEVINE. FURTHERMORE UNDERSTAND THAT PLANS AND SPECIFICATIONS ARE Page 1/2 MYGov.us 25-002685, 08/06/2025 al 11:36 AM Issued by: Courtney Cogburn MSP VIEW (1)MSP VIEW (2)AERIAL VIEW TAKE OFF QTY: MODULES:TRINA SOLAR TSM-415NE09RC.05 10.00 INVERTER:TESLA 5 1.00 INVERTER: INVERTER: MICRO/MCI:MCI-2 4.00 METER SOCKET: PLASTIC METER COVER: JBOX:1.00 DISCONNECT:SIEMENS GNF221RLLZA 1.00 FUSED DISCONNECT: FUSE REJECTION PINS: FUSE ADAPTER: DISCO HUB:ECHA075 1.00 FUSES: COMBINER PANEL: BACKFEED BREAKER:30A 1.00 MSA: COMBINER BREAKER: COMBINER BREAKER: COMBINER BREAKER: CELL KIT:1.00 ATTACHMENTS:FLASHKIT PRO 30.00 ATTACHMENTS: ATTACHMENTS: HOOK FLASHING:N/A (COMP SHINGLE)30.00 HOOK FLASHING: POP-UP FLASHING:RN3 (COMP SHINGLE)1.00 POP-UP FLASHING: RAIL:NXT 168RLM1 7.00 RAIL CLAMPS:SHCLMPM1 30.00 MIDS:CCLAMPD1 14.00 ENDS:NUHECLMP1 18.00 SPLICES:RLSPLCM2 2.00 MLPE BOLT/ GROUND LUG:NULGMLP1 8.00 NS WIRE CLAMPS:WRMCNSD1 8.00 WIRE RETENTION CLIPS:WRMCLPD1 12.00 MC4's:MALE 4.00 MC4's:FEMALE 4.00 CONDUIT TYPE 3/4" EMT 1.00 WORK INCLUDES PV ROOF ATTACHMENTS PV RACKING SYSTEM INSTALLATION PV MODULE AND INVERTER INSTALLATION PV EQUIPMENT GROUNDING PV SYSTEM WIRING TO A ROOF-MOUNTED JUNCTION BOX PV SYSTEM MONITORING EQUIPMENT (IF NEC.) PV LOAD CENTERS (IF NEC.) PV METERING (IF NEC.) PV DISCONNECTS PV GROUNDING ELECTRODE & BONDING TO (E) GEC PV FINAL COMMISSIONING NEC - 2020, IRC - 2021, IBC - 2021, IFC - 2021 (E) ELECTRICAL EQUIPMENT RETROFIT FOR PV SCOPE OF WORK THE INSTALLATION OF A SOLAR PHOTOVOLTAIC (PV) SYSTEM WHERE THE POWER GENERATED WILL BE INTERCONNECTED WITH THE LOCAL UTILITY COMPANY BY MEANS OF THE EXISTING ELECTRICAL SERVICE EQUIPMENT SHEET TABLE C-1 COVER PAGE A-1 SITE PLAN A-2 ATTACHMENT AND STRING LAYOUT A-3 MOUNTING PLAN E-1 ELECTRICAL 1-LINE DIAGRAM E-2 ELECTRICAL 3-LINE DIAGRAM E-3 WIRING CALCULATIONS E-4 WARNING LABELS S-1 MODULE SPEC SHEET S-2 INVERTER SPEC SHEET S-3 INVERTER SPEC SHEET 2 S-4 UNIRAC SPEC SHEET S-5 MOUNTING SPEC SHEET Rev Sheet Name Sheet Size Sheet Number ANSI B 11" X 17" DateDescription REVISIONS Project Name & Address 00Initial Design PARCEL # DESIGNER: 20789-7-6  SND250445 SSS # SYSTEM SIZE 4.150 kW DC 5.000 kW AC ADRIAN PE L A G I O D E L M A R 18 0 5 Q U A I L H O L L O W D R GR A P E V I N E , T X 7 6 0 5 1 32 . 9 5 6 8 6 1 7 , - 9 7 . 0 9 3 5 9 0 6 6/23/2025 SunSolar Solutions 8932 W Cactus Rd Peoria, AZ 85381 Phone: (602) 773-6675 LIC : 38275 EXPIRES : 07/06/26 PHOTOVOLTAIC ROOF MOUNT SYSTEM AHJ- 10 MODULES-ROOF MOUNTED- 4.150 kW DC, 5.000 kW AC COVER SHEET C-1 CITY OF GRAPEVINE SITE MAP DESIGN CRITERIA GROUND SNOW: 5 PSF WIND SPEED: 115 MPH EXPOSURE CATEGORY: C RISK CATEGORY: II EXP. 06/30/2026 S T A T E O F TEX A S S T R U C T UR A L E N G I N E ER LIC E N S E D F-15844 1805 Quail Hollow Dr, Grapevine, TX 76051 11 1 . 2 ' 53.0' ECB SES ED I UD SUB SYSTEM LEGEND 4 CONDUIT ROOF TOP JUNCTION BOX ROOF OBSTRUCTIONS TRINA SOLAR TSM-415NE09RC.0510 NEW FIRE PATHWAY SES SECTION & POINT OF INTERCONNECTION. TIED TO EXTERIOR UTILITY EXISTING EXTERIOR SERVICE ENTRANCE ROOF SECTIONS ASPHALT SHINGLE ASPHALT SHINGLE ARRAY 1 ARRAY 2 NEW MODULE - 5 SLOPE - 28° AZIMUTH - 90° MATERIAL - NEW MODULE - 5 SLOPE - 28° AZIMUTH - 270° MATERIAL - TOTAL ROOF AREA:3030 SQFT TOTAL PV ARRAY AREA: 559 SQFT PV COVERAGE:18.45% (1) 5.0kW TESLA INVERTERI NEW TESLA MCI-2 DEVICES MOUNTED ON THE BACK OF MODULE. EXTERIOR RUN MANUFACTURER: TESLA INC. MODEL NUMBER: 5.0kW 1538000-XX-Y(240V) MANUFACTURER: TRINA SOLAR MODEL NUMBER: TSM-415NE09RC.05 MANUFACTURER: TRINA SOLAR MODEL NUMBER: TSM-415NE09RC.05 UD UTILITY DISCONNECT SWITCH (VISIBLE LOCKABLE LABELED AC DISCONNECT (VLLD)) EXISTING LOAD CENTER INSIDE GARAGESUB EXISTING DISCONNECTED EXISTING COMBINER PANELECB 16 EXISTING QCELL Q.PEAK DUO BLK ML-G10.a+ 395W MODULES ASPHALT SHINGLE ARRAY 3 EXISTING MODULE - 16 SLOPE - 28° AZIMUTH - 270° MATERIAL - MANUFACTURER: Q. CELL MODEL NUMBER: Q.PEAK DUO BLK ML-G10.a+ 395 ONCOR UTILITY A. AC DISCONNECT LOCATED ON ACCESSIBLE EXTERIOR WALL WITHIN 10 FEET OF UTILITY METER Rev Sheet Name Sheet Size Sheet Number ANSI B 11" X 17" DateDescription REVISIONS Project Name & Address 00Initial Design PARCEL # DESIGNER: 20789-7-6  SND250445 SSS # SYSTEM SIZE 4.150 kW DC 5.000 kW AC ADRIAN PE L A G I O D E L M A R 18 0 5 Q U A I L H O L L O W D R GR A P E V I N E , T X 7 6 0 5 1 32 . 9 5 6 8 6 1 7 , - 9 7 . 0 9 3 5 9 0 6 6/23/2025 SunSolar Solutions 8932 W Cactus Rd Peoria, AZ 85381 Phone: (602) 773-6675 LIC : 38275 EXPIRES : 07/06/26 SITE PLAN A-1 N SCALE: 1" = 1'-0" 1 SITE PLAN A-1 AR R A Y 3 LOAD CENTER VISIBLE LOCKABLE LABELED DISCONNECT (EXTERNAL HANDLE) 6' MAX. 4' MIN. JURISDICTIONAL NOTES AND ELEVATION EXAMPLE VIEW 10' MAX 10" MIN. INVERTER UTILITY METER ESI ID: 10443720007477885 NOTE: AC DISCONNECT LOCATED ON ACCESSIBLE EXTERIOR WALL WITHIN 10 FEET OF ONCOR METER DRIVEWAY QUAIL HOLLOW DR FENCE PARCEL LINE AR R A Y 2 AR R A Y 1 36" RAKE FIRE SETBACK 18" RIDGE FIRE SETBACK (PER SIDE) BRIAN FENNEMORE MASTER ELECTRICIAN LIC : 38275 EXPIRES : 07/06/26 EXP. 06/30/2026 S T A T E O F TEX A S S T R U C T UR A L E N G I N E ER LIC E N S E D F-15844 1805 Quail Hollow Dr, Grapevine, TX 76051 # MODULE - 5 STRING #01 INVERTER 1 # MODULE - 5 STRING #02 TESLA 4'-0" MAXIMUM ATTACHMENT SPACING NUMBER OF MCI STRING #1 2 STRING #2 2 TOTAL 4 MID-CURRENT INTERRUPTER (MCI) & RAPID SHUTDOWN COMPLIANCE SYSTEM MID-CURRENT INTERRUPTER (MCI) MAP Rev Sheet Name Sheet Size Sheet Number ANSI B 11" X 17" DateDescription REVISIONS Project Name & Address 00Initial Design PARCEL # DESIGNER: 20789-7-6  SND250445 SSS # SYSTEM SIZE 4.150 kW DC 5.000 kW AC ADRIAN PE L A G I O D E L M A R 18 0 5 Q U A I L H O L L O W D R GR A P E V I N E , T X 7 6 0 5 1 32 . 9 5 6 8 6 1 7 , - 9 7 . 0 9 3 5 9 0 6 6/23/2025 SunSolar Solutions 8932 W Cactus Rd Peoria, AZ 85381 Phone: (602) 773-6675 LIC : 38275 EXPIRES : 07/06/26 SYSTEM LEGEND STRINGS = MCI DEVICE = ATTACHMENT POINTS 28 = RAFTER = RAIL A-2 ATTACHMENT AND STRING LAYOUT NEC - 2020, IRC - 2021, IBC - 2021, IFC - 2021 SCALE1:10 2 ATTACHMENT AND STRING LAYOUT A-2 N 2 X 4 PRE-FABRICATED TRUSSES @ 2'-0" SPACING PV ARRAY 1 - FLUSH MOUNTED PV ARRAY 2 - FLUSH MOUNTED BRIAN FENNEMORE MASTER ELECTRICIAN LIC : 38275 EXPIRES : 07/06/26 NOTES: MAXIMUM SPACING BETWEEN STANDOFFS SHALL NOT EXCEED 4'-0" W/ 1'-4" OVERHANGS. MAXIMUM HORIZONTAL TRUSS TOP CHORD DIMENSION BETWEEN INTERMEDIATE WEB SUPPORTS AT PV ATTACHMENT LOCATIONS SHALL NOT EXCEED 8'-4". INSTALLERS TO VERIFY FRAMING SIZE, SPACING AND MAXIMUM HORIZONTAL SPAN, AND NOTIFY E.O.R. OF ANY DISCREPANCIES BEFORE PROCEEDING EXP. 06/30/2026 S T A T E O F TEX A S S T R U C T UR A L E N G I N E ER LIC E N S E D F-15844 1805 Quail Hollow Dr, Grapevine, TX 76051 *AVERAGE WEIGHT PER MODULE(1 UNIT) = LBS58.791ASPHALT SHINGLE MOUNTING DETAIL NO SCALE 4'-0" 2'-0" (PORT R A I T ) (LAND S C A P E ) 3' MIN (WHE N R E Q U I R E D B Y A H J ) MAX 8 " 8" FLASHING L-FOOT 2 1/2 " MINIMUM ATTACHMENT DEPTH EMBEDDED IN WOOD BUILDING STRUCTURE ROOF DECK (STANDARD ROOF CONSTRUCTION) 5/16" STAINLESS STEEL LAG BOLT 3/4" MIN. EDGE DISTANCE TO CENTER OF LAG BOLT (WITHDRAWL) SECTION L-FOOT FLASHING DETAIL SM FLASHKIT PRO L-FOOT INSTALLATION SIDE SECTION L-FOOT FLASHING DETAIL ARRAY 1 5 MODULES (TYP. OF 1) ROOFING MATERIAL FRAMING 2"X4" TRUSS@24" O.C. SLOPE 28° AZIMUTH 270° ARRAY AREA (SF)108 (21.51SF X # OF MODULES) ARRAY LOADING (LBS)293.95 TOTAL WEIGHT OF ARRAY ARRAY LOADING (PSF)2.73 STANDOFFS MIN.14 MODULES (TYP. OF 1) ROOFING MATERIAL FRAMING 2"X4" TRUSS@24" O.C. SLOPE AZIMUTH ARRAY AREA (SF) ARRAY LOADING (LBS)TOTAL WEIGHT OF ARRAY ARRAY LOADING (PSF) STANDOFFS MIN. ARRAY 2 5 28° 90° 108 (21.51SF X # OF MODULES) 293.95 2.73 14 ASPHALT SHINGLE ASPHALT SHINGLE 5 1.5 LBS 8 LBS MID-CLAMP 6 0.17 LBS 1 LBS END-CLAMP 8 0.30 LBS 2 LBS RAIL LENGTH (LINEAR FT)4 0.79 LBS 3 LBS SPLICE BAR 0 0.65 LBS 0 LBSX X X X X = = = = = 1.5 LBS MID-CLAMP 0.17 LBS END-CLAMP 0.30 LBS RAIL LENGTH (LINEAR FT)0.79 LBS SPLICE BAR 0.65 LBSX X X X X = = = = = 5 8 LBS 6 1 LBS 8 2 LBS 4 3 LBS 0 0 LBS OPTIMIZERS OPTIMIZERS Rev Sheet Name Sheet Size Sheet Number ANSI B 11" X 17" DateDescription REVISIONS Project Name & Address 00Initial Design PARCEL # DESIGNER: 20789-7-6  SND250445 SSS # SYSTEM SIZE 4.150 kW DC 5.000 kW AC ADRIAN PE L A G I O D E L M A R 18 0 5 Q U A I L H O L L O W D R GR A P E V I N E , T X 7 6 0 5 1 32 . 9 5 6 8 6 1 7 , - 9 7 . 0 9 3 5 9 0 6 6/23/2025 SunSolar Solutions 8932 W Cactus Rd Peoria, AZ 85381 Phone: (602) 773-6675 LIC : 38275 EXPIRES : 07/06/26 MOUNTING PLAN A-3 EXP. 06/30/2026 S T A T E O F TEX A S S T R U C T UR A L E N G I N E ER LIC E N S E D F-15844 1805 Quail Hollow Dr, Grapevine, TX 76051 30A POINT OF INTERCONNECT, LOAD SIDE 705.12(B) BUSBAR CALCULATIONS SES BUS RATING: MAX CURRENT RATING: INVERTER(S) MAX OUTPUT X 125%:21A X 1.25 = 26.25A MAIN BREAKER: NEW TOTAL AMPERAGE 226.25A 200A 240A(200 X 120%) 200A UTILITY DISCONNECT SIEMENS GNF221RLLZA (240VAC, 30A, NON-FUSED, 2-POLE 10K AIC, TYPE 3R VISIBLE/LOCKABLE) CC MCI MCI INVERTER 1 JUNCTION BOX 600 V, NEMA 4 UL LISTED A B5 PV MODULES & 2 MCI-2 DEVICES IN BRANCH CIRCUIT #2 * NOTE: IF EXPOSED, CONDUCTORS SHALL BE IN 3/4" EMT CONDUIT PER NEC ARTICLES 250.120(C). 5 PV MODULES & 2 MCI-2 DEVICES IN BRANCH CIRCUIT #1 5.0 kW TESLA SINGLE PHASE INVERTER TESLA SOLAR RAPID SHUTDOWN DEVICE MANUFACTURER/MODEL MAXIMUM SYSTEM VOLTAGE (PVHCS) DC NOM INPUT CURRENT RATING (IMP) 1000V DC TESLA MCI-2 CONNECTOR 15A 19ADC MAX INPUT CURRENT (ISC) INVERTER 1 SPECIFICATIONS - MANUFACTURER MAX INPUT VOLTAGE 600 VOLTS SYSTEM ISC (A) PER MPPT 17 AMPS DC OPERATING VOLTAGE OUTPUT 240 VOLTS DC INPUT VOLTAGE RANGE 60-550 VOLTS MAX. AC CURRENT OUTPUT 21 AMPS SYSTEM OPEN CIRCUIT VOLTAGE SEE LARGEST STRING ON E-3 OCPD RATING 30 AMPS OPERATING CURRENT SEE 3-STRING CALCULATIONS MAX AC POWER OUTPUT 5000 WATTS TESLA 5.0kW 1538000-45-A(240V) TESLA 5.0 PV MODULE RATING @ STC MANUFACTURER MAX. POWER-POINT CURRENT (IMP)9.77 AMPS MAX. POWER-POINT VOLTAGE (VMP)42.50 VOLTS OPEN-CIRCUIT VOLTAGE (VOC)50.50 VOLTS SHORT-CIRCUIT CURRENT (ISC)10.40 AMPS MAX. REVERSE CURRENT 25 AMPS NOM. MAX. POWER AT STC (PMAX)415 WATTS MAX. SYSTEM VOLTAGE 1500 VDC TEMPERATURE COEFFICIENT PMAX -0.30° %/C TRINA SOLAR TSM-415NE09RC.05 CONDUIT CONDUCTOR SCHEDULE (UNLESS OTHERWISE SPECIFIED CONDUCTORS SHALL BE COPPER) TAG#DESCRIPTION # OF CONDUCTORS CONDUIT TYPE & SIZE A #10 CU PV WIRE (HR)FREE IN AIR* #8 BARE GROUND 1 GROUND FREE IN AIR* B 1 GROUND C 1 GROUND 4 4#10 AWG CU THWN-2 (HR) #10 GROUND 3/4" EMT 3/4" EMT #10 AWG CU THWN-2 (HR)3 3/4" EMT #10 GROUND 3/4" EMT NOTE: -ALL EQUIPMENT, WIRE AND TERMINAL SHALL BE RATED MINIMUM 75°C CONDUIT LOCATED ON ROOF SHALL BE INSTALLED A MINIMUM OF 7/8" ABOVE THE ROOF SURFACE PER NEC 310.15(B)(3)(C) ESI ID: 10443720007477885 VISIBLE LOCKABLE LABELED AC DISCONNECT (VLLD) NOTE: AC DISCONNECT LOCATED ON ACCESSIBLE EXTERIOR WALL WITHIN 10 FEET OF ONCOR METER EXISTING JUNCTION BOX EXISTING COMBINER BOX 15A/2P 20A/2P MONITORING ENVOY EXISTING DISCONNECT EXISTING WIRING L1L2 N TO UTILITY GRID BI-DIRECTIONAL UTILITY METER 1-PHASE, 3-W, 120V/240V 200A EXISTING 240V/200A BUSBAR RATING,SERVICE PANEL, SINGLE PHASE WITH A 200A MAIN DISCONNECT EXISTING EXISTING WIRING EXISTING WIRING EXISTING WIRING EXISTING SYSTEM EXISTING TAP KIT 16 EXISTING QCELL Q.PEAK DUO BLK ML-G10.a+ 395W MODULES 16 EXISTING ENPHASE IQ7+ MICRO INVERTERS ON THE BACK OF EACH MODULE Rev Sheet Name Sheet Size Sheet Number ANSI B 11" X 17" DateDescription REVISIONS Project Name & Address 00Initial Design PARCEL # DESIGNER: 20789-7-6  SND250445 SSS # SYSTEM SIZE 4.150 kW DC 5.000 kW AC ADRIAN PE L A G I O D E L M A R 18 0 5 Q U A I L H O L L O W D R GR A P E V I N E , T X 7 6 0 5 1 32 . 9 5 6 8 6 1 7 , - 9 7 . 0 9 3 5 9 0 6 6/23/2025 SunSolar Solutions 8932 W Cactus Rd Peoria, AZ 85381 Phone: (602) 773-6675 LIC : 38275 EXPIRES : 07/06/26 E-1 1-LINE DIAGRAM BRIAN FENNEMORE MASTER ELECTRICIAN LIC : 38275 EXPIRES : 07/06/26 30A POINT OF INTERCONNECT, LOAD SIDE 705.12(B) BUSBAR CALCULATIONS SES BUS RATING: MAX CURRENT RATING: INVERTER(S) MAX OUTPUT X 125%:21A X 1.25 = 26.25A MAIN BREAKER: NEW TOTAL AMPERAGE 226.25A 200A 240A(200 X 120%) 200A G UTILITY DISCONNECT SIEMENS GNF221RLLZA (240VAC, 30A, NON-FUSED, 2-POLE 10K AIC, TYPE 3R VISIBLE/LOCKABLE) CC MCI MCI G L1 L2 INVERTER 1 N G 240V +_ +_ JUNCTION BOX 600 V, NEMA 4 UL LISTED G L1 L1 L2 L2 L1 L1 L2 L2 A B5 PV MODULES & 2 MCI-2 DEVICES IN BRANCH CIRCUIT #2 * NOTE: IF EXPOSED, CONDUCTORS SHALL BE IN 3/4" EMT CONDUIT PER NEC ARTICLES 250.120(C). 5 PV MODULES & 2 MCI-2 DEVICES IN BRANCH CIRCUIT #1 5.0 kW TESLA SINGLE PHASE INVERTER TESLA SOLAR RAPID SHUTDOWN DEVICE MANUFACTURER/MODEL MAXIMUM SYSTEM VOLTAGE (PVHCS) DC NOM INPUT CURRENT RATING (IMP) 1000V DC TESLA MCI-2 CONNECTOR 15A 19ADC MAX INPUT CURRENT (ISC) INVERTER 1 SPECIFICATIONS - MANUFACTURER MAX INPUT VOLTAGE 600 VOLTS SYSTEM ISC (A) PER MPPT 17 AMPS DC OPERATING VOLTAGE OUTPUT 240 VOLTS DC INPUT VOLTAGE RANGE 60-550 VOLTS MAX. AC CURRENT OUTPUT 21 AMPS SYSTEM OPEN CIRCUIT VOLTAGE SEE LARGEST STRING ON E-3 OCPD RATING 30 AMPS OPERATING CURRENT SEE 3-STRING CALCULATIONS MAX AC POWER OUTPUT 5000 WATTS TESLA 5.0kW 1538000-45-A(240V) TESLA 5.0 PV MODULE RATING @ STC MANUFACTURER MAX. POWER-POINT CURRENT (IMP)9.77 AMPS MAX. POWER-POINT VOLTAGE (VMP)42.50 VOLTS OPEN-CIRCUIT VOLTAGE (VOC)50.50 VOLTS SHORT-CIRCUIT CURRENT (ISC)10.40 AMPS MAX. REVERSE CURRENT 25 AMPS NOM. MAX. POWER AT STC (PMAX)415 WATTS MAX. SYSTEM VOLTAGE 1500 VDC TEMPERATURE COEFFICIENT PMAX -0.30° %/C TRINA SOLAR TSM-415NE09RC.05 CONDUIT CONDUCTOR SCHEDULE (UNLESS OTHERWISE SPECIFIED CONDUCTORS SHALL BE COPPER) TAG#DESCRIPTION # OF CONDUCTORS CONDUIT TYPE & SIZE A #10 CU PV WIRE (HR)FREE IN AIR* #8 BARE GROUND 1 GROUND FREE IN AIR* B 1 GROUND C 1 GROUND 4 4#10 AWG CU THWN-2 (HR) #10 GROUND 3/4" EMT 3/4" EMT #10 AWG CU THWN-2 (HR)3 3/4" EMT #10 GROUND 3/4" EMT NOTE: -ALL EQUIPMENT, WIRE AND TERMINAL SHALL BE RATED MINIMUM 75°C CONDUIT LOCATED ON ROOF SHALL BE INSTALLED A MINIMUM OF 7/8" ABOVE THE ROOF SURFACE PER NEC 310.15(B)(3)(C) ESI ID: 10443720007477885 VISIBLE LOCKABLE LABELED AC DISCONNECT (VLLD) NOTE: AC DISCONNECT LOCATED ON ACCESSIBLE EXTERIOR WALL WITHIN 10 FEET OF ONCOR METER EXISTING JUNCTION BOX EXISTING COMBINER BOX G L1 L1 L2 L2 15A/2P 20A/2P +_ +_ MONITORING N G ENVOY G EXISTING DISCONNECT EXISTING WIRING L1L2 N N TO UTILITY GRID BI-DIRECTIONAL UTILITY METER 1-PHASE, 3-W, 120V/240V N G 200A EXISTING 240V/200A BUSBAR RATING,SERVICE PANEL, SINGLE PHASE WITH A 200A MAIN DISCONNECT EXISTING EXISTING WIRING EXISTING WIRING EXISTING WIRING EXISTING SYSTEM EXISTING TAP KIT 16 EXISTING QCELL Q.PEAK DUO BLK ML-G10.a+ 395W MODULES 16 EXISTING ENPHASE IQ7+ MICRO INVERTERS ON THE BACK OF EACH MODULE Rev Sheet Name Sheet Size Sheet Number ANSI B 11" X 17" DateDescription REVISIONS Project Name & Address 00Initial Design PARCEL # DESIGNER: 20789-7-6  SND250445 SSS # SYSTEM SIZE 4.150 kW DC 5.000 kW AC ADRIAN PE L A G I O D E L M A R 18 0 5 Q U A I L H O L L O W D R GR A P E V I N E , T X 7 6 0 5 1 32 . 9 5 6 8 6 1 7 , - 9 7 . 0 9 3 5 9 0 6 6/23/2025 SunSolar Solutions 8932 W Cactus Rd Peoria, AZ 85381 Phone: (602) 773-6675 LIC : 38275 EXPIRES : 07/06/26 3-LINE DIAGRAM E-2 BRIAN FENNEMORE MASTER ELECTRICIAN LIC : 38275 EXPIRES : 07/06/26 CONDUCTOR CALCULATIONS WIRE GAUGE CALCULATED FROM CODE ART. 310.15(B)(16) WITH AMBIENT TEMPERATURE CALCULATIONS FROM ART. 310.15(B)(2)(A). FOR "ON ROOF" CONDUCTORS WE USE THE 90°C COLUMN AMPACITY, THE RELEVANT AMBIENT TEMPERATURE ADJUSTMENT, AND RACEWAY FILL ADJUSTMENTS FROM 310.15(B)(16). CONDUIT SHALL BE INSTALLED AT LEAST 7/8" ABOVE THE ROOF DECK. FOR "OFF ROOF" CONDUCTORS WE USE THE 75°C COLUMN AMPACITY, OR THE 90°C COLUMN AMPACITY WITH THE RELEVANT AMBIENT TEMPERATURE AND RACEWAY FILL ADJUSTMENTS, WHICHEVER IS LESS.THE RATING OF THE CONDUCTOR AFTER ADJUSTMENTS MUST BE GREATER THAN, OR EQUAL TO, THE CONTINUOUS DUTY UPRATED OUTPUT CURRENT. CALCULATION EXAMPLE - WIRE RATING (90°C) X AMBIENT TEMPERATURE ADJUSTMENT X CONDUIT FILL ADJUSTMENT >= CONTINUOUS DUTY OUTPUT CURRENT ELECTRICAL NOTES · DESIGNED ACCORDING TO AND ALL CODE CITATIONS ARE RELEVANT TO THE 2020 NATIONAL ELECTRICAL CODE. · TAGS - USE 87% TEMPERATURE DERATE FOR CONDITIONS OF USE (ADJUSTED AMBIENT) · REFER TO FAULT CURRENT MITIGATION TABLE · PHOTOVOLTAIC UTILITY METER AND PHOTOVOLTAIC UTILITY DISCONNECT SWITCH TO BE INSTALLED AND LABELED AS REQUIRED BY ESS PAGE 11-43 · SYSTEM GROUNDING & BONDING DESIGNED IN COMPLIANCE WITH 690.47(C)3 AND 250.64(E) · EQUIPMENT SHALL BE LISTED, TESTED, AND MARKED TO WITHSTAND THE AVAILABLE SHORT CIRCUIT CURRENT NOTE: ROOF CONDUIT WILL BE INSTALLED A MINIMUM OF 7/8" ABOVE ROOF SURFACE PER 310.15 (B)(3)(C) NEC TABLE 310.15 (B)(3)(9) PERCENT OF VALUES NUMBER OF CURRENT CARRYING CONDUCTORS IN CONDUIT 0.80 4-6 0.70 7-9 0.50 10-20 ROOFTOP CONDUCTOR AMPACITIES DESIGNED IN COMPLIANCE WITH ART. 690.8, TABLES 310.15(B)(2)(A), 310.15(B)(3)(A), 310.15(B)(3)(C), 310.15(B)(16), CHAPTER 9 TABLE 4, 5, & 9. LOCATION SPECIFIC TEMPERATURE OBTAINED FROM ASHRAE 2017 DATA TABLES RECORD LOW TEMP - 1° AMBIENT TEMP (HIGH TEMP 2%)43° MINIMUM CONDUIT HEIGHT ABOVE ROOF 7/8" ROOF TOP TEMP 65° CONDUCTOR TEMPERATURE RATE 90° 415 WATTS 50.50 VOLTS 10.40 AMPS 25 AMPS TEMPERATURE COEFFICIENT PMAX MAX. SYSTEM VOLTAGE NOM. MAX. POWER AT STC (PMAX) MAX. REVERSE CURRENT MANUFACTURER PV MODULE RATING @ STC MAX. POWER-POINT CURRENT (IMP)9.77 AMPS MAX. POWER-POINT VOLTAGE (VMP)42.50 VOLTS OPEN-CIRCUIT VOLTAGE (VOC) SHORT-CIRCUIT CURRENT (ISC) 1500 VDC  -0.30° %/C INVERTER 1 SPECIFICATIONS - MANUFACTURER MAX INPUT VOLTAGE 600 VOLTS SYSTEM ISC (A) PER MPPT 17 AMPS DC OPERATING VOLTAGE OUTPUT 240 VOLTS DC INPUT VOLTAGE RANGE 60-550 VOLTS MAX. AC CURRENT OUTPUT 21 AMPS SYSTEM OPEN CIRCUIT VOLTAGE SEE LARGEST STRING ON E-3 OCPD RATING 30 AMPS OPERATING CURRENT SEE 3-STRING CALCULATIONS MAX AC POWER OUTPUT 5000 WATTS TESLA 5.0kW 1538000-45-A(240V) TESLA TEMPERATURE COEFFICIENT PMAX MAX. SYSTEM VOLTAGE NOM. MAX. POWER AT STC (PMAX) MAX. REVERSE CURRENT MANUFACTURER PV MODULE RATING @ STC MAX. POWER-POINT CURRENT (IMP) MAX. POWER-POINT VOLTAGE (VMP) OPEN-CIRCUIT VOLTAGE (VOC) SHORT-CIRCUIT CURRENT (ISC) TRINA SOLAR TSM-415NE09RC.05 ADJUSTED VOC ASHRAE EXTREME MIN. TEMP. ADJUSTED VMP ASHRAE HIGH TEMP. 53.41 VOLTS 40.36 VOLTS 415 WATTS 50.50 VOLTS 10.40 AMPS 25 AMPS 9.77 AMPS 42.50 VOLTS 1500 VDC  -0.30° %/C OCPD CALCULATIONS OCPD SIZED TO MAXIMUM OUTPUT CURRENT OF LISTED INVERTERS. PER ART. 690.8(A) (1) INVERTER TESLA 5.0 = MAX OUTPUT CURRENT 21 AMPS; OCPD = 21 X 1.25 = 26.25A BREAKER MAX OCPD NEED = 26.25 = 30A OCPD TAG WIRE # OF CONDUCTORS CONDUIT TYPE & SIZE CALCULATION AMPACITY CHECK A 10 GAUGE WIRE RATED FOR 35A FREE AIR 35 A x 0.87 x 1= 32.90A B 10 GAUGE WIRE RATED FOR 35A 35 A x 0.87 x 0.8= 24.36A C CONDUIT FILL CALCULATIONS TAG # WIRE AWG WIRE TYPE AREA OF WIRE (SQ-INCH)# OF WIRE TOTAL AREA OF WIRES (SQ-INCH) SIZE OF CONDUIT(INCH) AREA OF CONDUIT (SQ-INCH) MAX. OCCUPANCY FOR 3+ CABLES 40%RESULT A 10 PV WIRE (HR)FREE IN AIR 4 N/A N/A N/A N/A N/A 8 PV WIRE (BARE)FREE IN AIR 1 B 10 4 10 1 C 0.0211 0.0844 3/4"0.533 15.83%15.83%<40% 0.0211 IN 3/4" EMT 10 GAUGE WIRE RATED FOR 35A 3 IN 3/4" EMT 35A x 0.87 x 1= 30.45A 21A X 1.25= 26.25A < 30.45A THWN-2 (HR) GROUND 10 THWN-2 (HR)0.0211 3 0.0634 3/4"0.533 11.89%11.89%<40% 10 GROUND 0.0211 1 4 4 10.40A X 1.25= 13.00 A < 32.90A 10.40A X 1.25= 13.00A < 24.36A STRING CALCULATIONS ADJUSTED VOC (V) ADJUSTED VMP (V)ISC (A) IMP (A)MODULES MODULE (WATTS)POWER (WATTS) TOTAL 20.80A STRINGS 19.54A 5 MODULES 267.04V 10.40 9.77201.79V 5 MODULES 267.04V 201.79V 10.40 9.77 415 415 2075 2075 4150W 5 5 TRINA SOLAR TSM-415NE09RC.05 Rev Sheet Name Sheet Size Sheet Number ANSI B 11" X 17" DateDescription REVISIONS Project Name & Address 00Initial Design PARCEL # DESIGNER: 20789-7-6  SND250445 SSS # SYSTEM SIZE 4.150 kW DC 5.000 kW AC ADRIAN PE L A G I O D E L M A R 18 0 5 Q U A I L H O L L O W D R GR A P E V I N E , T X 7 6 0 5 1 32 . 9 5 6 8 6 1 7 , - 9 7 . 0 9 3 5 9 0 6 6/23/2025 SunSolar Solutions 8932 W Cactus Rd Peoria, AZ 85381 Phone: (602) 773-6675 LIC : 38275 EXPIRES : 07/06/26 WIRE CALCS E-3 BRIAN FENNEMORE MASTER ELECTRICIAN LIC : 38275 EXPIRES : 07/06/26 NEC 2020 LABELS UD DISCONNECT SOLAR ELECTRIC PV PANELS SOLAR PV SYSTEM EQUIPPED WITH RAPID SHUTDOWN TURN RAPID SHUTDOWN SWITCH TO THE "OFF" POSITION TO SHUT DOWN CONDUCTORS WITHIN THE ARRAY REMAIN ENERGIZED IN SUNLIGHT DUAL POWER SUPPLY SOURCES: UTILITY GRID AND PV SOLAR ELECTRIC SYSTEM ELECTRIC SHOCK HAZARD TERMINALS ON THE LINE AND LOAD SIDES MAY BE ENERGIZED IN THE OPEN POSITION MAIN PANEL WARNING PHOTOVOLTAIC SYSTEM AC DISCONNECT OPERATING VOLTAGE OPERATING CURRENT 240 VOLTS AMPS MAXIMUM RATED OUTPUT CURRENT OF THE CHARGE CONTROLLER OR DC-TO-DC CONVERTER (IF INSTALLED) MAXIMUM CIRCUIT CURRENT MAXIMUM VOLTAGE N/A A 267.04 V ELECTRIC SHOCK HAZARD THE DC CONDUCTORS OF THIS PHOTOVOLTAIC SYSTEM ARE UNGROUNDED AND MAY BE ENERGIZED WARNING INVERTER 1 PHOTOVOLTAIC SYSTEM AC DISCONNECT OPERATING VOLTAGE OPERATING CURRENT AMPS ELECTRIC SHOCK HAZARD TERMINALS ON THE LINE AND LOAD SIDES MAY BE ENERGIZED IN THE OPEN POSITION WARNING 240 VOLTS 21 21 26.00 POWER SOURCE OUTPUT CONNECTION DO NOT RELOCATE THIS OVERCURRENT DEVICE WARNING PV BACKFEED BREAKER Rev Sheet Name Sheet Size Sheet Number ANSI B 11" X 17" DateDescription REVISIONS Project Name & Address 00Initial Design PARCEL # DESIGNER: 20789-7-6  SND250445 SSS # SYSTEM SIZE 4.150 kW DC 5.000 kW AC ADRIAN PE L A G I O D E L M A R 18 0 5 Q U A I L H O L L O W D R GR A P E V I N E , T X 7 6 0 5 1 32 . 9 5 6 8 6 1 7 , - 9 7 . 0 9 3 5 9 0 6 6/23/2025 SunSolar Solutions 8932 W Cactus Rd Peoria, AZ 85381 Phone: (602) 773-6675 LIC : 38275 EXPIRES : 07/06/26 WARNING LABELS E-4