HomeMy WebLinkAboutSFRA2925-002733PHOTOVOLTAIC ROOF MOUNT SYSTEM MONA LEE SOLAR -ROOF MOUNTED - 8.200 KW DC, 7.600 KW AC 20 MODULES P­ 2405 WHITNEY LN, GRAPEVINE, TX 76051 PROJECT DATA GENERAL NOTES VICINITY MA PROJECT 2405 WHITNEY LN, ADDRESS GRAPEVINE, TX 76051 OWNER: ADALIA KRIVULKA PARCEL ID: 05788420 ESID: 10443720006672381 SCOPE: 8.200 KW DC ROOF MOUNT SOLAR PV SYSTEM WITH 20 HANWHA SOLAR: Q,PEAK DUO BLK ML-G1 O.C+ 41OW MONO MODULES WITH 20 SOLAREDGE:S440-5NC4ARS POWER OPTIMIZERS WITH 01 SOLAREDGE TECHNOLOGIES LTD. USE760OH-USMNBL75 (24OV) INVERTER AUTHORITIES HAVING JURISDICTION: BUILDING: CITY OF GRAPEVINE ZONING: CITY OF GRAPEVINE UTILITY: ONCOR PV-1 COVERSHEET PV-2 PLOT PLAN WITH ROOF PLAN PV-3 ROOF PLAN & MODULES PV-4 ELECTRICAL PLAN PV-5 ATTACHMENT DETAIL PV-6 ELECTRICAL LINE DIAGRAM PV-7 WIRING CALCULATION PV-8 LABELS PV-9 PLACARD PV-10 OPTIMIZERCHART PV-1 I + EQUIPM ENT S PECIFICATIONS RECEIVED: 7/16/2025 25-002733 2405 WHITNEY LANE SOLAR PANELS 1, ALL COMPONENTS ARE UL LISTED AND NEC CERTIFIED, WHERE WARRANTED 2020 2 THE SOLAR PV SYSTEM WILL BE INSTALLED IN ACCORDANCE WITH ARTICLE 690 OF THE NEC 2023. 3 THE UTILITY INTERCONNECTION APPLICATION MUST BE APPROVED AND PV SYSTEM INSPECTED PRIOR TO PARALLEL OPERATION 4 ALL CONDUCTORS OF A CIRCUIT, INCLUDING THE EGO, MUST BE INSTALLED INTHE SAME RACEWAY, OR CABLE, OR OTHERWISE RUN WITH THE PV ARRAY CIRCUIT CONDUCTORS WHEN THEY LEAVE THE VICINITY OF THE PV ARRAY 5 WHERE METALLIC CONDUT COINTANING DO CONDUCTORS IS USED INSIDE THE BUILDING, IT SHALL BE IDENTIFIED AS "CAUTION', SOLAR CIRCUIT" EVERY LOFT, 6 HEIGHT OF THE AC DISCONNECT SHALL NOT EXCEED 6 -7" PER NEC CODE 240 24 T U JCF, $I! F A T 2405 Whitney Ln, 51 VIA- T 7 A GROUNDING ELECTRODE SYSTEM IN ACCORDANCE WITH NEC 690 47 AND 250 50 THROUGH 60 AND 2501166 SHALL BE — ----- PROVIDED PER NEC GROUNDING ELECTRODE SYSTEM OF EXISTING BUILDING MAY BE USED AND BONDED TO THE SERVICE % ENTRANCE,IF EXISTING SYSTEM IS INACCESSIBLE OR INADEQUATE A SUPPLEMENTAL GROUNDING ELECTRODE WILL BE USED AT THE INVERTER LOCATION CONSISTING OF A UL LISTED WFT GROUND ROD WITH ACORN CLAMP GROUNDING ELECTRODE I E I CONDUCTORS SHALL BE NO LESS THAN #8 AWG AND NO LARGER THAN #6 AWG CCPPER AND BONDED To THE EXISTING 122602 GROUND NO ELECTRODE TO PROVIDE FOR A COMPLETE SYSTEM HOUSEPHOTO 9 PHOTOVOLTAC MODULES ARE TO BE CONSIDERED NONI-COMBUSTIBLE 2a865 9 PHOTOVOLTAJC INSTALLATION WILL NOT OBSTRUCT ANY PLUMBING, MECHANICAL, OR BUILDING ROOF VENTS DATE 06J2412025 PROJECT NAME &ADDRESS 10 ALL WIRING MUST BE PROPERLY SUPPORTED BY DEVICES OR MECHANICAL MEANS DESIGNED AND LISTED FOR SUCH USE WIRING MUST BE PERMANENTLY AND COMPLETELY HELD OFF THE ROOF SURFACE 11 ALL SGNAGE TO BE PLACED IN ACCORDANCE WITH THE LOCAL BUILDING CODE IF EXPOSED TO SUNLIGHT, IT SHALL BE UV RESISTANT ALL PLAQUES AND StGNAGE WILL BE INSTALLED AS REQUIRED BY THE NEC AND AHJ, 12 INVERTER(S) USED IN UNGROUNDED SYSTEM SHALL BE LL 1741 LISTED 13 THE INSTALLATION OF EQUIPMENT AND ALL ASSOCIATED WIRING AND INTERCONNECTION SHALL BE PERFORMED ONLY BY QUALIFIED PERSONS [NEC 5904,C)l 14 ALL OUTDOOR EQUIPMENT SHALL BE NEMA 3R RATED (OR BETTER), INCLUDING ALL ROOF MOUNTED TRANSITION BOXES AND SWITCHES 15 ALL EQUIPMENT SHALL BE PROPERLY GROUNDED AND BONDED IN ACCORDANCE WITH NEC ARTICLE 250 16, SYSTEM GROUND NG SHALL BE IN ACCORDANCE WITH NEC 690 41 17 PV SYSTEM CIRCUITS INSTALLED ON OR IN BUILD NOS SHALL INCLUDE A RAPID SHUTDOWN FUNCTION IN ACCORDANCE WITH NEC 690 12 18 DISCONNECTING MEANS SHALL BE LOCATED IN A VISIBLE, READILY ACCESSIBLE LOCATION WITHIN THE PV SYSTEM EQU PMENT OR A MAXIMUM OF 10 FEET AWAY FROM THE SYSTEM [NEC 690 13(k) 19 ALL WIRING METHODS SHALL BE IN ACCORDANCE WITH NEC 690 311 20 WORK CLEARANCES AROUND ELECTRICAL EQUIPMENT WILL BE MAINTAINED PER NEC 110 26(A)(I), 110 26(A)i2) AND 110 26(A,(3) 21 ROOFTOP MOUNTED PHOTOVOLTAIC PANELS AND MODULES SHALL BE TESTED, LISTED & I IDENTIFIED I N ACCORDANCE WITH UL1703 22 ELECTRICAL CONTRACTOR TO PROVIDE CCNDUT EXPANSION JOINTS AND ANCHOR CONDUIT RUNS AS REQUIRED PER NEC 23 IN ACCORDANCE WITH 2021 EC 1205 5, 2018 fFC 1204 4, AND 2015 IFC 605 11 2 A CLEAR, BRUSH -FREE AREA OF 10 FEET(3048 MM) SHALL BE REQUIRED FOR GROUND -MOUNTED PHOTOVOLTAIC ARRAYS 24 PANEL LAYOUT ORIENTATION IS SUBJECT TO CHANGE ON DESIGNED MOUNTING PLANES z uj Vn o 'A7 x > z w Lu I-— uj V 0 m Z < co uj w < < < 0 CODE REFERENCES DRA),ON BY ESR PROJECT TO COMPLY WTH THE FOLLOWING SHEETr,ANIE 2020 NATIONAL ELECTRICAL CODE (NEC I COVER SHEET 2021 INTERNATIONAL FIRE CODE (IFC) 202� INTERNATIONAL BUILDING CODE OBC) 2102 (IRC) SHEET SIZE ANSI B V 11"X17" signed ­P by DC Hernandez, David C. Hernandez,08o207141634 SHEETNUMEER 12.0400 PV-1 1 -1 'as 0311MR601=140121relloll 20X HANWHA SOLAR: Q.PEAK DUO BLKML-GlO,C+41OW MONO MODULES ROOF MOUNTED SOLAR PHOTOVOLTAIC MODULES OC SYSTEM SIZE: 8.200 KW DC AC SYSTEM SIZE: 7.600 KW AC EQUIPMENT SUMMARY 20 HANWHA SOLAR: Q.PEAK DUO BLK ML-GIO.C, 41OW MONO MODULES 20 SOLAREDGE:S440-5NC4ARS POWER OPTIMIZERS WITH 01 SOLAREDGE TECHNOLOGIES LTD. USE760OH-USMNBL75 (240V) INVERTER ROOF ARRAY AREA #1:- 23232 SO F. ROOF ARRAY AREA #2:- 126.72 SQ FT. ROOF ARRAY AREA #3:- 63.36 SO FT. ESID # 10443720006672381 METER# NOTE:- VISIBLE, LOCKABLE, LABELED AC DISCONNECT LOCATED WITHIN 1 O'OF ONCOR METER N fl ROOF#3 (3) HANWHA SOLAR:Q.PEAK DUO BLK ML-GIO.C+ 41 OW MONO MODULES WITH SOLAREDGE:S440-5NC4ARS POWER OPTIMIZERS ROOF#2 (6) HANWHA SOLAR: O.PEAK DUO BLK ML-Gl O.C+ 41 OW MONO MODULES WITH SOLAREDGE:S440-5NC4ARS POWER OPTIMIZERS (E)CHIMNEY ROOF #1 (11) HANWHA SOLAR: Q.PEAK DUO BLK ML-GlO.C- 41 OW MONO MODULES WITH SOLAREDGE:S440-5NC4ARS POWER OPTIMIZERS m PROPERTY LINE EQUIPMENT QUANTITY MANUFACTURER NAME MODELNUMBER VOLTAGE (V) Q.PEAK DUO BLK MONA LEE SOLAR SOLAR PV MODULES 20 HANWHA SOLAR: 1 000V ML-Gll).C* 41 OW SOLAREDGE SOLAREDGE: OPTIMIZERS 20 TECHNOLOGIES LTD. S440H5NC4ARS POWER 240V OPTIMIZERS SOLAREDGE INVERTER I USE760OH-USMNBL75 240V TECHNOLOGIES LTD. (240V) INVERTER (E) TREES (E) MAIN SERVICE PANEL (OUTSIDE) NOTE: THE ONCOR METER IS NOT THE CUSTOMER OWNED MEASUREMENT AND VERIFICATION METERLOCATED (E) UTILITY METER (OUTSIDE) DOWNSTREAM FROM THE ONCOR METER (N) VISIBLE. LOCKABLE,LABELED NON -FUSED AC DISCONNECT (LOCATED WITHIN 1 YOF UTILITY METER) (OUTSIDE) (N) SOLAREDGE TECHNOLOGIES LTD. USE760OH-USMNBL75 (240V) INVERTER (OUTSIDE) RBIISIONS DESCRIPTMN I 111TI JR111 Lu Lu m 0 1 _STo HOUSE (E) FENCE (E) GATE EXISTING DRIVEWAY PROPERTY LINE I IS VISIBLE, LOCKABLE, LABELED AC DISCONNECT (VLLD) INCLUDED? DISTANCE BETWEEN VLLD AND ONCOR METER JIS THE NORTH DIRECTION SYMBOL INCLUDED? YES 10 FEET YES ESIID 10443720006672381 SERVICE ADDRESS 2405 WHITNEY LN, GRAPEVINE, TX 76051 METER NUMBER 166 610 521 22692 DATE 06!24f2025 PRJJECT NAME & ADDRESS DRAWN BY ESR SHEET NAME PLOT PLAN WITH ROOF PLAN SHEET SIZE ANSI B 11" X 17" SHEETNJOIEER PV-2 MODULE TYPE, DIMENSIONS & WEIGHT ARRAY AREA & ROOF AREA CALC'S NUMBER OF MODULES = 20 MODULES (N) SOLAREDGE TECHNOLOGIES LTD. ROOF #OF ARRAY ROOF AREA AREA ROOF AREA COVERED MODULE TYPE = HANWHA SOLAR: Q.PEAK DUO BLK ML-Gl i 41OW MONO MODULES USE760OH-USMNBL75 i INVERTER (OUTSIDE) MODULES Gq Ft,) (Sq. Ft) BY ARRAY MONA LEE SOLAR MODULE WEIGHT = 48.5 LBS 122.0 KG. MODULE DIMENSIONS = 74x 41.1 21 A2 SF (N) VISIBLE. LOCKABLE.LABELED NON -FUSED AC DISCONNECT #j 11 232,32 530 776 44 (LOCATED WITHIN 10! OF UTILITY METER) (OUTSIDE) #2 6 126 72 445914 28 (E) UTILITY METER (OUTSIDE) (E) MAIN SERVICE PANEL (OUTSIDE) #s3 63,36 203.172 31 TOTAL 20 422,40 2671887 15 ROOF#3 (3) HANWHA SOLAR:Q.PEAK DUO BLK ML-Gli 41 OW MONO MODULES WITH SOLAREDGE:S440-5NC4ARS POWER OPTIMIZERS 6; 8 _n _n m x m m m m U) (h --i --I co 03 ROOF #2 (6) HANWHA SOLAR: Q.PEAK DUO BILK ML-Gl O.C+ 41 OW MONO MODULES WITH SOLAREDGE:S440-5NC4ARS POWER OPTIMIZERS {E) CHIMNEY ROOF #1 (11) HANWHA SOLAR: Q.PEAK DUO BILK ML-G10.C- 41 OW MONO MODULES WITH SOLAREDGE:S440-5NC4ARS POWER OPTIMIZERS N:EPE`cf� TE PL*WI;MN'� pFz7,- ­z 1�,' � I ,j . z ROOF TYPE ASPHALT SHINGLE ROOF #OF ROOF RAFTER RAFTER MODULES PITCH AZIMUTH SIZE SPACING *1 11 28' 180, ZX6" 24 #2 6 28' 270' 2"X6" 24 #3 3 28' 270' 2'X6" 24' ROOF ACCESS POINT ESID#10443720006672381 METER# 166 610 521 T yJ,`i PI.GE *E £ J. SY: Pa"VO! IEZ TIC FE 1 3SIS Lf HANWHA SOLAR: 18" FIRE SETBACK Q.PEAK DUO BLK 18" FIRE SETBACK NEF ;[N; Flm ML-GI0.C+410W MONO MODULES ROOF PLAN & MODULES (N) EVEREST K2 SYSTEMS CROSSRAIL 44-X SCALE: 118" = V-0" (63) EVEREST K2 MULTI MOUNT ATTACHMENTS LEGEND SOLAREDGE TECHNOLOGIES LTD. J� USE760OH-USMNBL75 (241 INVERTER AC DISCONNECT -MAIN SERVICE PANEL -UTILITY METER -VENT, ATTIC FAN (ROOF OBSTRUCTION) -ROOFATTACHMENT -RAFTER REVISIONS IF11RITION 1,11TI REv Z.rt 122602 2 a DATE 0612412025 PROJECT NAME & ADDRESS < v z 0 - Y; i LE.) x LU > u z z (y w F— W v r) !E z < Fn 3: >w w oLo n- < r') < DRA)AN BY ESR SHEET NAME ROOF PLAN & MODULES SHEET SIZE ANSI B 11" X 17" SHEET NU,IEER PV-3 BILL OF MATERIALS EQUIPMENT QTY DESCRIPTION SOLAR PV MODULES 20 HANVvHASOLAR O.PEAK DUO ELK ML-GIO C+ 410WMON0 MODULES SOLAREDGE TECHNOLOGIES LTD INVERTER 01 UGE7F00H-USMNBL75 i24OV) INVERTER OPTIMIZERS 20 SOLAREDGE S440.5NC4ARS POWER OPTIMIZERS 6"XC,'X4" UL LISTED, STEEL WATER TIGHT NEVA JUNCTION BOXES 3 TYPE 3R, UL LISTED RAILS 13 EVEREST K2 SYSTEMS CROSSRAL 44-X, 166" SPLICE 2 SPLICE KIT MODULE CLAMPS 22 MODULE CLAMPS END CLAMPS 36 �MID END CLAMPS ATTACHMENTS 63 EVEREST K2 MULTI MOUNT ATTACHMENTS ESID # 10443720006672381 METER # 166 610 521 NOTE: THE ONCOR METER IS NOT THE CUSTOMER OWNED MEASUREMENT AND VERIFICATION METER,LOCATED DOWNSTREAM FROM THE ONCOR METER NOTE:- VISIBLE, LOCKABLE, LABELED AC DISCONNECT LOCATED WITHIN 1 O'OF ONCOR METER (20) SOLAREDGE:S440-5NC4ARS POWER OPTIMIZERS STRING#2 (09 MODULES) �i 1) JUNCTION BOX (TYP.) STRING#1 (11 MODULES) ELECTRICAL PLAN SCALE: 118" = V-C" (N) SOLAREDGE TECHNOLOGIES LTD. USE760OH-USMNBL75 (24OV) INVERTER (OUTSIDE) (N) VISIBLE. LOCKABLE.LABELED NON -FUSED AC DISCONNECT (LOCATED WITHIN 10'OF UTILITY METER) (OUTSIDE) (E) UTILITY METER (OUTSIDE) (E) MAIN SERVICE PANEL (OUTSIDE) ZZ STRING LEGENDS STRING RNG#I STRING #2 MONA LEE SOLAR RE,10ONS DE CRI PTION I DATE I Wl (N) CONDUIT z DATE 0612412025 rn PRWECT NAME & ADDRESS r- z < z (D _j w r- D o x > UJI Z Z X W N Uj V r") z < Fn >w w Lo Co- < ry < 0 DRAIIIN BY LEGEND ESR JUNCTION BOX SHEET NAME -MAIN SERVICE PANEL ELECTRICAL PLAN I -UTILITY METER AC DISCONNECT SHEE qZE SOLAREDGE TECHNOLOGIES LTD. ANSI -USMNBL75 (24OV) INVERT USE7600H ER 11 " X 17" CONDUIT SHEETNU1,16ER SOLAREDI,IC4ARS PV-4 POWER OPTIM IZERS ATTACHMENT DETAIL (SIDE VIEW,I 71— 51 SCALE: N T S M7 'cv (N) 13X25MM T-BOLT KIT nlil P:'�.V- R J �q 3 Fl� �LT (E) ASPHALT SHINGLE 'V—F,-jVCP 2'X6- RAFTER tci ATTACHMENT DETAIL (ENLARGED VIEW) 7711 SCALE: N.T.S. INU \MP (N) CROSSRAIL 44-X 166", MILL (N) K2 MULTI MOUNT ATTACHMENTS um��• i� (1) 5/16" LAG SCREW WITH MINIMUM 2,5" THREAD EMBEDMENT, STRUCTURAL DETAIL SEALED PENETRATION MONA LEE SOLAR REVISIONS DERC R,p PON "c" {WC S40%1F 122602 rATE 06124,2025 7711-�ECTNl �E&ADDRESTS —J UJ :D 0 >- >< > Z F- Qui r uj r") z LLI Lo 0Ui 0- - < 4 N (Y DRA)AN BY ESR SHEET W-A E ATTACHMENT DETAIL SHEET SSE ANSI B 11" X 17" SHEETW,IEER PV-5 EQUIPMENT QUANTITY MANUFACTURER NAME MODEL NUMBER VOLTAGE(V) INTERCONNECTION NOTES: GROUNDING & GENERAL NOTES: 1 INTERCONNECTION SIZING, LIMITATIONS AND COMPLIANCE 1 GROUNDING ELECTRODES AND GROUNDING ELECTRODE CONDUCTORS SOLAR PV MODULES 20 HANWHA SOLAR: Q.PEAK DUO BILK l000v DETERMINED IN ACCORDANCE WITH [NEC 705 121, AND [NEC 690 591 ADDITIONAL GROUNDING ELECTRODES SHALL BE PERMITTED TO BE INSTALLED IN ML-GI0.C+410W 2 GROUND FAULT PROTECTION IN ACCORDANCE WITH [NEC 215 91, ACCORDANCEWITH 2-0 52 AND 250 54 GROUND NO ELECTRODES SHALL BE SOLAREDGE: [NEC 230 9E] PERVII TTED TO BE CONNECTED DIRECTLY TO THE PV MODULE FRAME(S) OR SUPPORT MONA LEE SOLAR SOLAREDGE 3, ALL EQUIPMENT TO BE RATED FOR BACKFEECING STRUCTURE PER [NEC 6W 47(BII OPTIMIZERS 20 S440-5NC4ARS POWER 240V 4 PV BREAKER TO BE POSITIONED AT THE OPPOSITE END OF THE 2 PV INVERTER SUNGROUNDED, TRANSFORMER -LESS TYPE TECHNOLOGIES LTD. OPTIMIZERS BUSBAR RELATIVE TO THE MAN BREAKER 3 DO DEC AND AC EGO TO REMAIN UNSPLICED, OR SPLICED TO EXISTING SOLAREDGE USE7600H-USMNBL75 ELECTRODE INVERTER I TECHNOLOGIES LTD. (240V) INVERTER 240V DISCONNECT NOTES 4 ANY EXISTING WIRNG INVOLVED W TH PV SYSTEM CONNECTION THAT IS I DISCONNECTING SWITCHES SHALL BE WIRED SUCH THAT WHEN FOUND TO BE INADEQUATE PER CODE SHALL BE CORRECTED PRIOR TO FINAL THE SWITCHISOPENED THE CONDUCTORS REMAINING LIVE ARE INSPECTION NOTE THE ONCOR METER IS NOT THE CUSTOMER OWNED MEASURE N I k,D CONNECTED TO THE TERMINALS MARKED'L!NE SIDE'(TYPI CALLY 5 SOLADECVJUNCTION BOX QUANTITIES, AND PLACEMENT SUBJECT TO CHANGE IN VERIFICATION METERLOCATED DOWNSTREAM FROM THE ONCOR THE UPPER TERMI NALS) THE FIELD - SOLADECK/JUNCTI ON BOX DEPICTED ON ELECTRICAL DIAGRAM 2 AC DISCONNECT MUST BE ACCESSIBLE TO QUALIFIED UTILITY REPRESENT W RE TYPE TRANSITIONS PERSONNEL, BE LOCKABLE, AND BE A VISIBLE -BREAK SWITCH 6 AC DISCONNECT NOTED IN EQUIPMENT SCHEDULE OPTIONAL IF OTHER 3 DISCONNECT MEANS AND THEIR LOCATION SHALL BE IN AC DISCONNECTING MEANS IS LOCATED WITHIN 10'OF SERVICE DISCONNECT ACCORDANCE WITH [NEC 210.70(AK 1)] AND (NEC 230 70i A)(2)1 7 RACEWAYS AND CABLES EXPOSED TO SUNLIGHT ON ROOFTOPS SHOULD BE I F 4 C A INSTALLED MORE THAN OF' ABOVE THE ROOF USING CONDUIT SUPPORTS 8 ALL NEW SERVICE INSTALLATICNIS AND REPLACEMENTS REQUIRE A RACKING NOTES: 3�' VL, 1 30,671, THE SURGE -PROTECTIVE DEVICE (lPD) IN WITH [NEC 2, 1 BOND EVERY OTHER RAiL NTH #6 BARE COPPER SPD SHALL BE TYPE 1 OR TYPE 2 AND IS REQUIRED TO BEAN INTEGRAL PART OF THE SERVICE EQUIPMENT OR LOCATED IMMEDIATELY ADJACENT THERETO NOTE - VIS SUE, LOCKABLE, LABELED AC DI SCONNECT LOCATED WITHIN 10'OF ONCOR SOLAREDGE TEC�INOLQGES LTD METER REM SCjNS 120) HAM'HA SOLAR Q PEAK CU F I USE 760OH-USMNBL75 (240V} I NVERTER R TO UTILITY OD DESCRIPTION HITI lEl ML­I� 240 VAC, 32 OA, 9914 CEC WE GHTED SHIELDED 4 lrW MD" EFFICI ENCY, NEMA 3R, ILL LISTED, INTERNAL CATE& M —L2 GFDI WTH INTEGRATED DO DISCONNECT CABLE N BI-DIRECTIONAL UTILITY STRNG#1 METER FrSCONIIECT 120,24OV, 1�, 341 IVAI 240V, 10, 3W METER NO, - 166 610 521 IT 60A RATED Li f + NEMA3R _2 (E) MA! N BREAKER TO (EATON N HOUSE 240V, 200A,2P IS) MAIN SERV CE — ---------- LINE PANEL,200A DG222URB) RATED, 240tf DATE 06,24/2025 LOADSIDE PROJECT NAME & ADDRESS 77—Ti N INTERCONNECTION AT 40AJ2P PER ART 705 1? ( #2 MAINPANEL 171 11, 21 1____ T i L 30ov, NEVA DR, BACK -FEED BREAKER z 0 JUNCTION BOX, UL LISTED REP LI LOAD N G uj 2020 NEC 7D5 12(B), 31(2) x Lu L2 > z z --------- LI A4 AVVG CU, MIAIN ix Lu I_ Ld Ll G BONDING JUMFER V 0 —= z PER CEC 250 8 &250 28 3: > SOLAREDGE POWER OPTI MIZERS S4401 0 VISIBLE, SEC (E) BONDING JUMPER L0 Lli DO I NPUT POWER, 440WATTS LABELED AC DISCONNECT PER NEC 250 92{k 2) _j W 0 CL MAXIMUM INPUT VOLTAGE- 60 VDC LOCATED WITHIN 3 4 < MPPT RANGE - 8 TO 60 VDC OF PPL METER EXISTING GROUNDING N n- MAXIMUM SHORT STRING CURRENT- 14 5 ADD ELECTRODE SYSTEM TO EARTH < CD MAXIMUM OUTPUT CURRENT - 15 ADO RISE NEC 25052,250511A) STRI ING LIMITATIONS- 8 TO 25 OPTIMIZERS, ESID #10443720006672381�� 6800 WATTS STC PER STRING MAXIMUM METER# 166 610 521DRM1N BY ESIO 10443720006672381 DO SYSTEM SIZE 8 200 MN DC BACKFEED BREAKER CALCULATION (1201/.RULEI: ESR 2405 WHITNEY LN GRAPEVINE, TX AD SYSTEM SIZE 7,600 W AC (MAIN BUSS X 12 - MAIN BREAKER) — (INMERTERCUKRENT'l 25; SERVICE ADDRESS (200A A 1 2 - 200A) — (40A) SHEET HAM E 76051 20 HANNHA SOLAR 0 PEAK DUO ELK ML-rl 0 C+ 41 OW MONO MODULES WITF- (40A) — (40A) HENCE OK ELECTRICAL LINE METER NUMBER 166 610 521 20 SOLAREDGE S440-5NC4ARS POWER OPTIMIZERS WITH I I 1 IS VISIBLE, LOCKABLE, LABELED AC DISCONNECT LLD 01 SOLAREDGE TECHNOLOGIES LTD USE16IIH-USIINEIL-1 124W) INVERTER CONDUIT DIAGRAM YES OTY CONDUCTORINFORMATION CONDUIT TYPE SIZE INCLUDED? (01) STIM NO OF 11 MODULES AND SHEET SIZE IDISTANCE BETWEEN VILUD AND ONCOR METER 10 FEET ;01)STRNGOF 09 MODULESCONNECTED IN SERIES 14) flOAWG - PVWRE'USE­2 NA rVA ANSI B CIS THE NORTH DIRECTION SYMBOL INCLU YES (1) #6AWG - BARE COPPER I N FREE N R (4) #10AWG - CU,THVVN42 311, 11 " X 17" INSTALLER; ELECTRCIAN NOTE: (1, #I0AWG - CU,THW\­2 GND EMT OR LRAC SHEETNUMBER ELECTRICAL LINE DIAGRAM EC IS TO MEASURE VOLTAGE BEFORE STARTING WORK (2) #SAWG - CU,TI-WN-2 IF RESULT IS ANY OTHER VOLTAGE MEASURED THAN 1201240V (1) #8AWS - CU'71-WN,2 N EMT OR PVC 34" PV-6 Pvlo SCALE NTS IS OBSERVED, DO NOT PROCEED CONTACT ENGINEER Il) #10AWC - CU,TI­WN2 ONO SOLAR MODULE SPECIFICATIONS INVERTER SPECIFICATIONS � AMBIENT TEMPERATURE SPECS � PERCENT OF NUMBER OF CURRENT' HANWHA SOLAR Q PEAK DUO BLK SOLAREDGE � � RECORD LOW TEMP -9" � VALUES CARRYING CONDUCTORS IN EMT`- ' MANUFAC7URERr M11OD'EL# ML-G10C+ 410VVPVNIODULES MANUFACTURER+MODEL# TECHNOLOGIES LTD USE76001-FUSMNBL75 AMBIENTTEMF!HIGHTEMP2°af 40' I 80 4-6 MONALEE SOLAR VMP 3?,84V (240VI INVERTER I 70 7-0 1 IMP 10 89A NOMINAL AC POWER I MODULE TEMPERATURE COEFFICIENT ENT OF ?'fK 7 600 kW Voc 02 50 t0.20 MCC 45, 37V NOMINAL OUTPUT VOLTAGE 240 VAC NOMINAL OUTPUT CURRENT 32A Sc 11 20A TEMP, COEFF. VOC-0,27%tK MODULE DIMENSION 741 x 411'VV x 1260 AC F£EDERCALCUa.ATMS iUt'1z TtA TORS AMPACRY AMBIENTTEMP.} FEEDERCKR- AMPACITY£t7NII1RT CCXtlDtAT CIRCtAT ORIGIN DES NUIT IVOE'AEC }25 DOEIZE}_-CON AMPS "FiA' NEUTRALSILE GROUND SIZE TUCZOR �FORAM&EMPERATU £NO€C CORCONDU AMPACITY CCONDUCTORS-BYCAMPACItY(A1 CHPACITECk YNEC DERAT£D � LENGTH RESISTANCE DROP AT SITE FOCI (xi { - !AC IN RACEWAY ) 3dd.PS;B3{i3 310.75{C3iS} {At t } (OHM/.FT) RAVOLTAGE .ax..,,.,- A:?.S'J"�4C.,fix ,Aw" sI < CUMULATIVE VOLTAGE - REVISIONS DFSCRIPTI(1N ( Di%TE REV DC FEEDER CALCULATIONS - TOTALCC VITIATION FACTOR DERATION FACTOR FULL LOAD CIRCUITVOLTAGE Ft$`S.2S DCPD "PLA,I 15'C AMPACDY AMBIENT CONDUCT 90'C FORAMBIENT FORCONDUCTORS- WCAMPACITY AMPACTY FEEDER CONDUCTOR VOLTAGE CONDUIT CONDUIT CIRCUIT ORIGIN MAYS INATI DESTINATION (V) (A} SkXE (At GROUND S'ZE CONDUCTOR SITE AMPACITY LENGTH DROP AT FIA CHECK n1 TEMP_('C) ORS IN AMYACitY(ap 7EPflP£RA7 URL PER RACEWAY N€C DERAfi ED;A) CHECK aT SIZE FILL {+a7 (A} (Ai (O.MANC£ ifEETJ (flxMIKFT} {3b} ' RACEWAY NEC 316.ES{8)41} 31415{C}j13 STk Nei+, i,11C'iN WX 't) Snti 137=. 26 RAF, (GPPFR++f, As4( 1 C (`Ab7C. 1s - if J `TR Ni, i I.,S[T.'JN ICY ''it 3,Ga ;P'S 20 ( 3AFr CJP"[R a.Y.i. n C n44C 3S" '�. - 4' 2 _., C,51 Y - 15 z »5 , _, :i. A- --,. CaCT (`.N Bs`X _ f*.4'rkT�'R xn.) - ECZ<- 'e'"+ 't--- -£.ql,^^. AVv C, ,-_{.. Yif d`N5 ?E --_- .7C. - -t -- "vi <^.t J= _ - -;: Ili F _.,-- STr,nq i Voitagc Drap ... _ • --. 51—g2 Voltage Drop : ',;. ( DATE 06124,2025 PRO. ECT NA'M E K ADDRESS ELECTRICAL NOTES 1. ALL EQUIPMENT TO BE LISTED BY UL OR OTHER NRTL, AND LABELED FOR ITS APPLICATION. 2. ALL CONDUCTORS SHALL BE COPPER, RATED FOR 600 V AND 90 DEGREE C WET ENVIRONMENT. 8. WIRING, CONDUIT, AND RACEWAYS MOUNTED ON ROOFTOPS SHALL BE ROUTED DIRECTLY TO, AND LOCATED AS CLOSE AS POSSIBLE TO THE NEAREST RIDGE, HIP, OR VALLEY. 4. WORKING CLEARANCES AROUND ALL NEW AND EXISTING ELECTRICAL EQUIPMENT SHALL COMPLY WITH NEC 110.26. 5. DRAWINGS INDICATE THE GENERAL ARRANGEMENT OF SYSTEMS. CONTRACTOR SHALL FURNISH ALL NECESSARY OUTLETS, SUPPORTS, FITTINGS AND ACCESSORIES TO FULFILL APPLICABLE CODES AND STANDARDS. 6, WHERE SIZES OF JUNCTION BOX, RACEWAYS, AND CONDUITS ARE NOT SPECIFIED. THE CONTRACTOR SHALL SIZE THEM ACCORDINGLY. 7. ALL WIRE TERMINATIONS SHALL BE APPROPRIATELY LABELED AND READILY VISIBLE. 8. MODULE GROUNDING CLIPS TO BE INSTALLED BETWEEN MODULE FRAME AND MODULE SUPPORT RAIL, PER THE GROUNDING CLIP MANUFACTURER'S INSTRUCTION. 9, MODULE SUPPORT RAIL TO BE BONDED TO CONTINUOUS COPPER G.E.C. VIA WEEK LUG OR ILSCO GBL-4DBT LAY -IN LUG. 10. TEMPERATURE RATINGS OF ALL CONDUCTORS, TERMINATIONS, BREAKERS, OR OTHER DEVICES ASSOCIATED WITH THE SOLAR PV SYSTEM SHALL BE RATED FOR AT LEAST 75 DEGREE C. z O L1.I J Li LU kF - Lu z `C w w Lo < 4< 0 W Q DRACirN BY ESR SHEET NAM E WIRING CALCULATIONS SHEET FZE ANSI B 11" X 17" SHEETNJI,IEER PV-7 & WARNING ELECTRIC SHOCK HAZARD TERMINALS ON THE LINE AND LOAD SIDES MAY BE ENERGIZED IN THE OPEN POSITION LABEL-1 LABEL LOCATION. AC DI SCONNECT COMBINER CODE REF NEC 6901318) POWER SOURCE OUTPUT CONNECTION. DO NOT RELOCATE THIS OVERCURRENT DEVICE LABEL- 2 LABEL LOCATION MAIN SERVICE PANEL (ONLY IF SOLAR I S RACK�FED) SUBPANEL (ONLY IF POLAR S BACK,FED) CODE REP NEC 7 5 12,B),3)(2) SOLAR PV SYSTEM EQUIPPED WITH RAPID SHUTDOWN TURN RAPID SHUTDOM SV\ATa-I TO THE "OFF" POSITION TO SHOT DOWN RV BY STEM AND REDU.�E SHOOK HAZARD IN THE ARRAY LABEL 3 LABEL LOCATION MAIN SERVICE PANEL CODE REF NFC2022I20541(1)&NEC(SQ56tC, Ar jr f A LA -Vi"! OW k LABEL, 4 LABEL LOCATI CN� A - DISCONNECT CODE REP NEC 690 56t1)(2) LABEL-5 LABEL LOCATI ON EIATCONDLATRACEWAY SOLADECK I JUNCTION BOX CODE REP NEC 690 31 (D)Q) 240 V V 32 A LABEL6 LABEL LOCATION INVERTER CODE REF NEC 690 54 F i&WARNING DUAL PCI SOURCE SECOND WARNING IS PHOTOVOLTAIC SYSTEM LABEL- 7 LABEL LOCATI ON PRODLICTI ON M ETER UTILITY METER MAIN SERVICE PANEL SUSPANEL CODE REP NEC 705 12(C) & NEC 690 59 P2 V, 5 A LABEL- 8 LABEL LOCATION INVERTER ODE REF NEC 690 53 LABEL 09 LABEL LOCATION. A' DISCONNECT _4 1- LABEL- 10 LABEL LOCATION AC DISCONNECT PHOTOVOLTAIC SYSTEM CIRCUIT IS BACKFEED LABEL 11 LABEL LOCATION MAIN SERVICE PANEL (ONLY IF SOLAR IS BACK -FED) SUBPANEL (ONLY IF SOLAR IS BACK -FED) CODE REP NEC 690 13 (F), NEC 705 12{13)!34) & NEC 690 59 Ai L �.: 5t APPIIUJ,,­. MONA LEE SOLAR REMCiNS DESCRIPTION 111TI III_ DATE 06,24/2025 PROJECT NAME & ADDRESS z CD LU -i > (.5 x w z >- Ix w zw v 0 Z < U) >w w DRA`I1N BY ESR SHEET NAM E LABELS SHEET SIZE ANSI B 11 " X 17" SHEETNUMBER PV-8 MONA LEE SOLAR I ji if] IIIIIIIII Mil 4 ql;L*ll!j :4111111 41-Wol 2:01714 zi (E) UTILITY METER (OUTSIDE) ---- (N) MAIN SERVICE PANEL (OUTSIDE) — (N) VISIBLE. LOCKABLELABELED NON -FUSED AC DISCONNECT (LOCATED WITHIN 10' OF UTILITY METER) (OUTSIDE) 1) SOLAREDGE TECHNOLOGIES rD. USE760OH-USMNBL75 (24OV) IVERTER (OUTSIDE) (N) JUNCTION BOX (TYP.) N (N) PV ARRAY 2405 WHITNEY LN, GRAPEVINE, TX 76051 DIRECTORY PERMANENT PLAQUE OR DIRECTORY PROVIDING THE LOCATION OF THE SERVICE DISCONNECTING MEANS AND THE PHOTOVOLTAIC SYSTEM, (ALL PLAQUES AND SIGNAGE WILL BE INSTALLED AS OUTLINED WITHIN: NEC 690.56(A)(B), (NEC 705.101) LABELING NOTES 1 LABELS CALLED OUT ACCORDING TO ALL COMMON CONFIGURATIONS. ELECTRIC AN TO DETERMINE EXACT REQUIREMENTS IN THE FIELD PER CURRENT NEC AND LOCAL CODES AND MAKE APPROPRIATE ADJUSTMENTS 2 LABELING REQUIREMENTS BASED ON THE 2014 NEC, OSHA STANDARD 19010 145, ANSI Z535. 3 MATERIAL BASED ON THE REQUIREMENTS OF THE AUTHORITY HAVING JURISDICTION 4 LABELS TO BE OF SUFFICIENT DURABILITY TO WITHSTAND THE ENVIRONMENT INVOLVED [NEC 110 211 REMShDNS D111"llf"T'IN NTI Ill_ DATE 06,24/2025 PROJECT NAME &ADDRESS z Lu > LU Z Z Fy w I-- Ui V 0 —= z < F5 3: 5 I Lu L0 LIJ 0 CL < ry '�t < (N n, < CD -eg DRMMN BY E.S. ' R�;UIA �EO FOR C�,m 'N SHEET NAME PLACARD jzaB sIl__ Al SIZE ANSI 11 " X 17" SHEETNUMBER MUl bl:, 1�­RUVE" IPV_9 MONA LEE SOLAR -IT r-1 E VINE j- 16PPr REV15IONS DESCRIPTIMN D11TE SATE 0612412026 FFZD.ECT NAP A E &ADDRESS z ICE w D C) _j (o r-- > z Wz *� w Z > w < LED C) D- "i < EN < DRA),uN BY ESR SHEET NAME OPTIMIZER CHART SHEET SIZE ANSI B 11" X 17" SHEETNWEER PV-10 OPEAK DUO BLK ML-G10+ SERIES ocells 395-415Wp I 132Celis 21,1% Maximum Module Efficiency � W—M& Includes Domestic Content Breaking the 21% efficiency barrier 2751 A reliable investment Enduring high performance ,r-C Extreme weather rating Par beyond the standard Th. id-1 Oluv— for 'DCA Module Option: 177-771 A;= MONA LEE SOLAR ACH- SERIES a Mechanical Specification U— a Electrical Characteristics ----- - --------- ------- REVISIONS POWER CLASS 395 400 40S 410 415 DESCRIPTION MTE REV -1,." r'r 0 M EF, P". mpp t" as 122602 DATE 06124,2025 —P 'A — PRCJ.ECT NA,E& ADDRESS 0,0L, PERFORMANCE WARRANTY PERFORMANCE AT LOW IRRADIANCE UJ _3 UJ F W LU LO W C) < q. < TEMPERATURE COEFFICIENTS < qr,— t sr;—P a Properties for System Design DRAIAN BY lv� 1.1-11'.""',— A-1- I" 6173,� 7 ESR SHEET NAME EQUIPMENT Qualifications and Certificates SPECIFICATION SHEET siZE ANSI B 11 " X 17" SHEETNJIIEER ocells PV-1 1 MONA LEE SOLAR SolarEdge Home Hub Inverter USA Domestic Content Eligible* 0 Single Phase, for North America SE WOH-US 1 SEWOOH-US /SE7600H- US/ SE I 0000H-US/ M SEI 140OH-US co r) C 0 Madie i­AUSA1";' SolarEdge's USA -manufactured residential single phase inverter offering for storage and backup applications SolarEdge Home Hub Inverter SolarEdge Home Hub Inverter USA Domestic Content Eligible USA Domestic Content Eligible Single Phase, for North America Single Phase, for North America S1 i800H-US .,SB7,)0Hr tIS", 5-1600H US SE 1000('*1 UIS SET 1400H Us 5E�8OOH-USISF570OH-(1S557606H u5,rSE10000H-115/SF11400H-US D-1—TO. I w REMSONS MCRIPTION I 011TE I REV tM opt ySpS it 122602 DATE 06124,2025 PRCJ.ECT NAM E & ADDRESS z LIJ > LLJ Li LU F- Ld z >w w LO C) < 4 < 0 N W < (D DRAM BY ESR SHEET NAME EQUIPMENT SPECIFICATION SHEET siZE ANSI B 11" X 17" SHEETWMEER PV-12 MONA LEE SOLAR Sbecifically designed to vork with Salaydge Faster installations wim sim ' obtfisol wtre residential Inserters management and easy assembly using a smqlil bolt Distarts abnormal PV connector frehavro,, farevanting potential safety ,sues Flex,ble system design fut tuaxilrluln space U01,zatpon Mod.le, laser voltage shutdown fit installs, and !ireftqnter safety Compatible with Wawa] PV inoduies Sopef:o' effide-Ity f99'5%j 2 Meets NEC iegwitnrerit} fat aic fault protection tAKII and fsliotovoftaic Rapti Shutdown System Mitigates all types of module rnismato loss fPVRSS) from manufacturing vorame to partial shad no Solaredge.corn solia r Y Residential Power Optimizer For North America S500B / S650B S440 OUTPUT DURING OPERATION tPOWER OPTIMIZER CONNECTED TO OPERATING SOLAREDGE INVERTER) OUTPUT DURING STANDBY IPOVVER OPTIMIZER DISCONNECTED FROM SOLAREDGE INVERTER OR INVERTER OFF) STANDARD COMPLIANCE INSTALLATION SPECIFICATIONS RoMS REVISIONS MCRIPTION I 0117E I REV Orr, LZ 122602 DATE 06124,2025 PRCJ.ECT NAS E & ADDRESS z LIJ _3 (.) x > Eu Z W LU F- w cr Z > W W LO ED < 4 < 0 N X < (D DRAWN BY ESR SHEET NAME EQUIPMENT SPECIFICATION SHEET siZE ANSI B 11 " X 17" SHEET WOEER PV-13 MONA LEE SOLAR MONA LEE SOLAR Units: mm (in) ft , - REV' SONS MCR IPTION I 011TE I REV wwr ySpS4�0CwtF�S LZ '5W6 , E — HE I R 0 1 D I I 1 2 122602 DATE 06124,2025 PRCJ.ECT NAM E & ADDRESS z UJ > Lu W LU z F- w z >w Lu Lo C) CL < < DRAM BY ESR SHEET NAME EQUIPMENT SPECIFICATION SHEET siZE ANSI B 11 " X 17" SHEETW4EER PV-15 MONA LEE SOLAR e support PV systems �- Formerly Everest Solar Systems jk v} - REVISIONS MCRIPTION I NTE REV we ySpS4�0CwtF LZ PAv,O ,C... .kCRNnN0E2 1202 25 i� DATE 06124,2025 � MMM��N �, �, PRCJ.ECT NAM E &ADORESS a.. J r- LU i tJ .... z w to < 4 < ✓K ±Sint rd J= Q Technical Data - - DRAM BY ESR SHEET NAME s i,i, t F„4 ,,id EQUIPMENT SPECIFICATION SHEET siZE ANSI B r." 1, is „-,"a M n'T,, 11" X 17" - - - - SHEET NY,iEER PV-16 CERTIFICATE OF COMPLIANCE MONA LEE SOLAR Certificate Number E467724 Report Reference E467724-20150108 Date 2021-April-07 Issued to: K2 Systems LLC 2835 La Mirada Dr, Suite A Vista CA, 92081 US REMSONS MCRIPTION NTE REV This is to certify that MOUNTING SYSTEMS, MOUNTING DEVICES, representative samples of CLAMPING DEVICES AND GROUND LUGS FOR USE WITH PHOTOVOLTAIC MODULES AND PANELS Everest Crossrail System, utilizing Crossrail 48, 48-S, 48-X, 48-XL, 44-X rails, and Everest MiniRail XPRess System for 122602 System Fire Classification and Bonding, 'v, k1M' DATE 06124,2025 Everest CrossRail System, utilizing CrossRail 80 for PROJECT NAM E & ADDRESS Bonding. Se Z 0 Have been investigated by UL in accordance with the —1 UJ :D ( ' > - Z F_ Standards indicated indicated on this Certificate. — Z W LU F- Ld — r Z 3: > W LO W C) 0- Standard(s) for Safety: UL 2703, Mounting Systems, Mounting Devices, < 4 < Clamping/Retention Devices, and Ground Lugs for use with < Flat -Plate Photovoltaic Modules and Panels. DRAM BY Additional Information: See the UL Online Certifications Directory at ESR hftr,)s://ia.ulDrosr)lector.com for additional information SHEET NAME EQUIPMENT This Certificate of Compliance does not provide authorization to apply the UL Mark. Only the UL Follow -Up SPECIFICATION Services Procedure provides authorization to apply the UL Mark. SHEET aIZE Only those products bearing the UL Mark should be considered as being UL Certified and covered under UL*s ANSI B Follow -Up Services- 11 " X 17" Look for the UL Certification Mark on the product. SHEETWMEER PV-17 T 4-f Z..., _j 3 -j Eaton General duty non -fusible safety Switch, single -throw, 60 A, NEMA 3R, Rainproof. Painted galvanized steel. Two -pole, Two - wire 240 V Eaton s-Cloi HWY Mt4o5rlW Ife:y 7VI 73?44238 381.' '4 38 8 Om 41b Eaten Selimg P-Cy 25 00 one t 1) year NEC 230 62 (C) Cnmplialli Banta, 1— fill. HAI r,f ms ai4r,thm "I the 081:1-1hs f-, the of 01, plectIf UL U,,ted ,h,Hv,e, o­­ MONA LEE SOLAR NEMA 3R 240v iql,,fi,liuv T— p0n, G,ne.lo,ly it,,H,l REVfRONS 2 MCRIPTION rxlTE REV N.111.,14be i qla-thro. - HE I R ii . 0 1 22602 Hel 2 DATE 06124,2025 TROJBCT —NAME & ADDRESS < Z Uj > Z LU 2 LU F -Ne Z < E.ml Corporal— Pit, W LO co- < q. < r, 4, 1ped e. R ubltD0 Petro kad Urn s a reqistorpd iraviintark, E A N E'non clom Affothcr tr,,d(!rl­k5;j'o 202-41EWo, AllRight, proHe nyf1h,lfrn,,olech— DRAM BY W" ESR SHEET NAME EQUIPMENT SPECIFICATION L!, SHEET SIZE 0 EZ ANSI B 11"X17" L SHEETNUMEER PV-18 W,W N