HomeMy WebLinkAboutPMISC2025-003158City of Grapevine t, !)"1 }, Q i PO Box 95104 Project 1 Grapevine, Texas 76099 817 410 3166 to the pool Project Description: Add backflow device equipment "Shorewood Park Town Homes" 14101F r,, Issued on: 08/13/2025 at 1:20 PM ADDRESSINSPECTIONS 1924 Shorewood Dr. Grapevine, TX 76051 1. TCEQ Backflow Certification Submit 3. Plumbing Final 2. Backflow Device Inspection LEGAL Shorewood Park Town INFORMATION FIELDS Homes Blk B Lot n/a Shorewood Park Town —APPLICANT NAME (individual) Above and Beyond Plumbing Services Homes All Units & 100% —APPLICANT PHONE NUMBER 239-565-3618 Of Common Area VALUATION 500 PERMIT HOLDER Tanner Henshaw FF TOTAL A Above and Beyond Plum Plumbing Miscellaneous Fee $ 37.00 $ 37.00 $ 37,00 Bing Services LLC (469) 995-5069 TOTALS $ 37.00 $ 37.00 $ 0.00 COLLABORATORS READ AND SIGN ® Tanner Henshaw Alcove and Beyond I HEREBY CERTIFY THAT THE FOREGOINGIS CORRECT TO THE BEST OF MY KNOWLEDGE ALL K ILL F I T Plumbing Services THE DOCUMENTSV Y THE BUILDINGDEPARTMENT AND 1 LLC COMPLIANCE WITH THE CITY OF GRAPEVINE CODES REGULATING (469) 995-5069 CONSTRUCTION. IT IS UNDERSTOOD THAT THE ISSUANCE OF THIS PERMIT DOES NOT GRANT OR AUTHORIZE ANY VIOLATION OF ANY CODE OR OWNERS ORDINANCE OF THE CITY OF GRAPEVINE. • Shorewood Associates I FURTHER CERTIFY THAT ALL WORK THAT IS REQUIRED TO COMPLY WITH Lp ANY FEDERAL, STATE, AND / OR LOCAL LAW REGARDING ENERGY CONSERVATION WILL BE PERFORMED IN ACCORDANCE WITH THOSE Inez Medlock Sullivan LAWS, AND THAT VERIFICATION OF ENERGY CODE COMPLIANCE SHALL BE • Shorewood SUBMITTED TO THE CITY UPON REQUEST. Townhomes imm August 13, 2025 Date MYGOV.US 25-003158, 08/13/2025 at 1:20 PM ISSUed by: Courtney Cogburn Texas Commission on Environmental Quality BACKFLOW PREVENTION ASSEMBLY TEST AND MAMENANCE REPORT Thefblloorm must be coqKletedfoT each assembl% tested. A signed and dated original must be submitted to tbe:. ublic water su�ll,lier for rccordkc-v, in:! oses'., NAMEOFPWS: Gna i PWS ib#: 220Q0 13, PWS MAILING ADDRESS: 501 suo", PWS CONTACT -_ PERSON: Backflow Coordinator ADDRESS OF SERVICE: The backilow prevention assembly detailed below has been tested and maintained as required by coninussion regulations and is certified to be oatim_, within accept;ible parameters. TYPE OF BACKFLOW PREVENTION ASSEMBLY (BPA): P! Reduced Pressure Principle (RPBA) 0 Reduced Pressure Principle -Detector (RPBA-D) Type H 10 [jr Double Check Valve (DCVA) Double Check -Detector (DCVA-D) Type R Pressure Vacuum Breaker (P`VB) w 0 Spill -Resistant Pressure Vacuum Breaker (SVB) Manufacturer: Main: Bypass: I Size: Main: Model Number: Main: Bypass�j 1 BPA Location: Serial Number: Main: Bypass- i BPA Serves: PERMIT NUMBER - Old Model/Serial Reason for test: � New Existing EJ Replacement Is the assembly installed in accordance with manufacturer recommendations and/or local codes? Is the assembly installed on a non -potable water supply (auxiliary)? Bypass: El ;E11 No X,Ves�JOJNo TEST RESULT Type 11 Reduced Pressure Principle Assembly (RPBA) Assembly PVB & SVJ3 PAS91 01 DCVA 'Relief Valve Bypass Check Air Inlet Check Valve Check FAEL 13 1" Check 2m Check** 1� 5 IWdal Test 1,Held at LL:�L peed Held at nWqld Opened at !Held at L psid Held at 1 psid Opened at, t d ate:�,Closed Tight 0 1 �iClosa Tight Ml! In psid J Tight. :01 lClosed TIght ;E] Did not open lol I psi 13 Leaked Time: i [ 13,eaked Leaked �,.Did not icil U-caked Did it fully open J!open (Yes 01 /No 1111 Repairs and Main:' Materials Used " ypass: Test After Held at !PsidtHeldat___Jpsid qFOpenedat- �.Heldatl_lpsid! edat! usid Held at Ppen R ir Q D UI psid IClosed psid �ea Closed Closed Tight ID ITight ate in e 2111 check. numeric readim-1 re,juired for DCVA only Differential pressure gauge used- Potable: Non -Potable:" SN. Mak&Model. Date tested for accurac alar Company Name: Licensed Tester Name j"nt/T � jge)- Company Address: t ice nsed Tester Name (Signature): Company one W. BPAT License # License Expiration Date: The above is certified to be true at the time of testing. TEST RECORDS MUST BE KEPT FOR AT LEAST THREE YEARS [30 TAC §290.46(B)] ** USE ONLY MANUFACTURER'S REPLACEMENT PARTS TCEQ-20700 (Revision 04-04-2019) Page 1 of 1