HomeMy WebLinkAbout94251218.0019.2025-06-09.Concrete Compressive Strength TestReport Number: Service Date: Report Date: Task: Client Grapevine, TX 2701 Ira E Woods Avenue 121 Community ParkSawyers Construction, Inc (TX) Attn: Randy Sawyers 2307 Oak Lane Suite 210 Grand Prairie, TX 75051 817-268-8600 Reg No: F-3272 Fort Worth, TX 76118-7102 1801 Handley Ederville Rd Concrete & Reinforcing Steel Observations and Testing 94251218.0019 06/09/25 06/19/25 CONCRETE COMPRESSIVE STRENGTH TEST REPORT Project Project Number: 94251218 Specified Strength:28 days Mix ID: Supplier: Batch Time: Truck No.: 260-3 Cow Town Material Information 1023 1049 Plant: Ticket No.: 2 746358 Field Test Data Test Air Content (%): Result Specification 6 3 - 6 3.5 3 - 6 85 Max 95 79 144.0 4,000 Slump (in): psi @ Concrete Temp. (F): Ambient Temp. (F): Plastic Unit Wt. (pcf): Yield (Cu. Yds.): Sample Information Sample Date: Sampled By: Weather Conditions: Sample Time:06/09/25 1050 Kevin Ortega Clear skies 10 10 0 0 See Exhibit A-1Sample Location: Placement Method:Direct Discharge Water Added Before (gal): Water Added After (gal): Accumulative Yards:Batch Size (cy): Retaining WallPlacement Location: Sample Description:4-inch diameter cylinders Laboratory Test Data Set Avg Diam.Area DateDate Test Age at Load Max Strength Comp Frac No.ID Spec Received Tested (days)Type(in)(sq in)(lbs)(psi) Tested ByCond. Cyl. 1 A 4.00 12.57 06/10/25 06/16/25 7 42,820 2 CAPGood 3,410 1 B 4.00 12.57 06/10/25 07/07/25 28 1 C 4.00 12.57 06/10/25 07/07/25 28 1 D 4.00 12.57 06/10/25 07/07/25 28 1 E 06/10/25 Hold Initial Cure:Final Cure:Onsite Cooler Moist Room Comments:Note: Reported air content does not include Aggregate Correction Factor (ACF). Samples Made By: Terracon Obtain samples of fresh concrete at the placement locations, perform required field tests and cast compressive strength samples.Services: Reported To: Contractor: Report Distribution: (1) Sawyers Construction, Inc (TX), Randy Sawyers (1) Sawyers Construction, Inc (TX), Brandy Altonji (1) Sawyers Construction, Inc (TX), Maribel Cortez Doyle Mackey Senior Project Manager Sawyer construction Greg Sutheimer with Sawyer Construction Reviewed By: ASTM C 31, ASTM C39, ASTM C138, ASTM C143, ASTM C172, ASTM C231, ASTM C1064, ASTM C1231Test Methods: Terracon Rep.: Kevin Ortega The tests were performed in general accordance with applicable ASTM, AASHTO, or DOT test methods. This report is exclusively for the use of the client indicated above and shall not be reproduced except in full without the written consent of our company. Test results transmitted herein are only applicable to the actual samples tested at the location (s) referenced and are not necessarily indicative of the properties of other apparently similar or identical materials . Page 1 of 1CR0001, 3-31-22, Rev.7 Exhibit 1801 Handley Ederville Rd Fort Worth, TX 76118-7102 817-268-8600 terracon.com 121 Community Park Concrete Compressive Strength Test A-1 Report Number: 94251218.0019 Service Date: 06/09/2025 Employee: Ortega, Kevin Scale: Refer to Drawing Test Retested / Accepted Deviation