Loading...
HomeMy WebLinkAbout94251218.0004.2025-04-03.Field Density TestingFIELD DENSITY TEST REPORT Report Number: Service Date: Report Date: Task: 94251218.0004 04/03/25 04/08/25 Earthwork Observations and Testing 1801 Handley Ederville Rd Fort Worth, TX 76118-7102 817-268-8600 Reg No: F-3272 Client Sawyers Construction, Inc (TX) Attn: Randy Sawyers 2307 Oak Lane Suite 210 Grand Prairie, TX 75051 121 Community Park 2701 Ira E Woods Avenue Grapevine, TX Project Project Number: 94251218 (%) Compaction (%) Content Water No. Mat. Material Information Density Max. Lab (%) Content Opt. Water Ref. No. Proctor Laboratory Classification and Description (pcf)Test Method Project RequirementsLab Test Data Min 95Min 14.01113.314.094251218.0001 Reddish Brown Clayey Sand with Trace of Gravel ASTM D698 Field Test Data No.Test Location Elev.No. Test Lift /Mat.Depth Density Probe Wet Content Water (%) Content Water Density Dry (%) Percent Compaction (in)(pcf)(pcf)(pcf) Pavillion 1 10’ North & 8’ West of SE corner of Pavillion 2/-2.8’1 6 124.6 17.0 15.8 107.6 95 2 5’ South & 15’ West of NE corner of pavillion 2/-2.8’1 6 122.9 15.7 14.6 107.2 95 3 26’ South & 40’ West of NE corner of pavillion 2/-2.8’1 6 126.0 17.7 16.3 108.3 96 4 Retest of Test 1 of Report.0003 1/-3.5’1 6 131.8 19.0 16.8 112.8 100 5 Retest of Test 2 of Report .0003 1/-3.5’1 6 127.2 17.9 16.4 109.3 96 6 12’ North & 17’ east of SW corner of pavillion (retest) 1/-3.5’1 6 127.5 17.2 15.6 110.3 97 Comments: Datum:Top of existing grade Std. Cnt. M:Std. Cnt. D:1772665 Test and/or retest results on this report meet project requirements as noted above. Last Cal. Date:Model:Make:S/N:32312 Fort Worth - Troxler 3440 06/25/2024 Perform in-place density and moisture content tests to determine degree of compaction and material moisture condition.Services: Reported To: Contractor: Greg Sutheimer with Sawyer Construction Sanchez Construction Doyle Mackey Senior Project Manager Report Distribution:Reviewed By: Terracon Rep.: Alden Massey ASTM D6938Test Methods: The tests were performed in general accordance with applicable ASTM, AASHTO, or DOT test methods. This report is exclusively for the use of the client indicated above and shall not be reproduced except in full without the written consent of our company. Test results transmitted herein are only applicable to the actual samples tested at the location (s) referenced and are not necessarily indicative of the properties of other apparently similar or identical materials . CR0007, 03-31-22, Rev.8 Page 1 of 1 Photo Log Report Number:94251218.0004 Service Date:04/03/25 1801 Handley Ederville Rd Report Date:04/08/25 Fort Worth, TX 76118-7102 Task:Earthwork Observations and Testing 817-268-8600 Reg No: F-3272 Sawyers Construction, Inc (TX) Attn: Randy Sawyers CT0001, 10-16-13, Rev.10 Page 1 of 1 (P1) test 1-3 East (P2) test 4-6 West (P3) pavilion