Loading...
HomeMy WebLinkAbout94251218.0006Rev1.2025-04-14.Concrete Compressive Strength Test - CopyReport Number: Service Date: Report Date: Task: Client Grapevine, TX 2701 Ira E Woods Avenue 121 Community ParkSawyers Construction, Inc (TX) Attn: Randy Sawyers 2307 Oak Lane Suite 210 Grand Prairie, TX 75051 817-268-8600 Reg No: F-3272 Fort Worth, TX 76118-7102 1801 Handley Ederville Rd Concrete & Reinforcing Steel Observations and Testing 94251218.0006 04/14/25 05/13/25 Revision 1 - 28-day results CONCRETE COMPRESSIVE STRENGTH TEST REPORT Project Project Number: 94251218 Specified Strength:28 days Mix ID: Supplier: Batch Time: Truck No.: 260 Cowtown Material Information 1112 P38 Plant: Ticket No.: 3A 1371451 Field Test Data Test Air Content (%): Result Specification 3 3 - 5 3.7 3 - 6 80 Max 95 80 147.0 3,500 Slump (in): psi @ Concrete Temp. (F): Ambient Temp. (F): Plastic Unit Wt. (pcf): Yield (Cu. Yds.): Sample Information Sample Date: Sampled By: Weather Conditions: Sample Time:04/14/25 1254 Keaon Griffin Clear/Light wind 5/5 10 0 0 Sidewalk west side of pavilion 50ft west from northwest corner of pavilion Sample Location: Placement Method:Chute Water Added Before (gal): Water Added After (gal): Accumulative Yards:Batch Size (cy): SidewalkPlacement Location: Sample Description:4-inch diameter cylinders Laboratory Test Data Set Avg Diam.Area DateDate Test Age at Load Max Strength Comp Frac No.ID Spec Received Tested (days)Type(in)(sq in)(lbs)(psi) Tested ByCond. Cyl. 1 A 4.00 12.57 04/15/25 04/21/25 7 47,590 2 CAPGood 3,790 1 B 4.00 12.57 04/15/25 05/12/25 28 64,760 2 CAPGood 5,150 1 C 4.00 12.57 04/15/25 05/12/25 28 61,810 2 CAPGood 4,920 1 D 4.00 12.57 04/15/25 05/12/25 28 62,810 2 CAPGood 5,000 Average (28 days) 5,020 1 E 04/15/25 Hold Initial Cure:Final Cure:Outside in shade Moist Room Comments:Average compressive strength of 28 day cylinders complies with the specified strength. Note: Reported air content does not include Aggregate Correction Factor (ACF). Samples Made By: Terracon Obtain samples of fresh concrete at the placement locations, perform required field tests and cast compressive strength samples.Services: Reported To: Contractor: Report Distribution: (1) Sawyers Construction, Inc (TX), Randy Sawyers (1) Sawyers Construction, Inc (TX), Brandy Altonji (1) Sawyers Construction, Inc (TX), Maribel Cortez Doyle Mackey Senior Project Manager Sawyer construction Greg with sawyer construction Reviewed By: ASTM C 31, ASTM C39, ASTM C138, ASTM C143, ASTM C172, ASTM C231, ASTM C1064, ASTM C1231Test Methods: Terracon Rep.: Keaon Griffin The tests were performed in general accordance with applicable ASTM, AASHTO, or DOT test methods. This report is exclusively for the use of the client indicated above and shall not be reproduced except in full without the written consent of our company. Test results transmitted herein are only applicable to the actual samples tested at the location (s) referenced and are not necessarily indicative of the properties of other apparently similar or identical materials . Page 1 of 1CR0001, 3-31-22, Rev.7 Exhibit 1801 Handley Ederville Rd Fort Worth, TX 76118-7102 817-268-8600 terracon.com 121 Community Park Concrete Compressive Strength Test A-1 Report Number: 94251218.0006 Service Date: 04/14/2025 Employee: Griffin, Keaon Scale: Refer to Drawing Test Retested / Accepted Deviation