Loading...
HomeMy WebLinkAbout94251218.0009.2025-05-09.Field Density Testing - CopyFIELD DENSITY TEST REPORT Report Number: Service Date: Report Date: Task: 94251218.0009 05/09/25 05/09/25 Earthwork Observations and Testing 1801 Handley Ederville Rd Fort Worth, TX 76118-7102 817-268-8600 Reg No: F-3272 Client Sawyers Construction, Inc (TX) Attn: Randy Sawyers 2307 Oak Lane Suite 210 Grand Prairie, TX 75051 121 Community Park 2701 Ira E Woods Avenue Grapevine, TX Project Project Number: 94251218 (%) Compaction (%) Content Water No. Mat. Material Information Density Max. Lab (%) Content Opt. Water Ref. No. Proctor Laboratory Classification and Description (pcf)Test Method Project RequirementsLab Test Data Min 95Min 14.01113.314.094251218.0001 Reddish Brown Clayey Sand with Trace of Gravel ASTM D698 Field Test Data No.Test Location Elev.No. Test Lift /Mat.Depth Density Probe Wet Content Water (%) Content Water Density Dry (%) Percent Compaction (in)(pcf)(pcf)(pcf) Pickle Ball Court 1 See Exhibit A-1 FG 1 6 124.1 16.6 15.4 107.5 95 2 See Exhibit A-1 FG 1 6 123.2 16.0 14.9 107.2 95 Parking Area 3 See Exhibit A-1 FG 1 6 125.0 17.2 16.0 107.8 95 4 See Exhibit A-1 FG 1 6 124.8 17.4 16.2 107.4 95 Comments: Datum:Final grade Std. Cnt. M:Std. Cnt. D:1351583 Test and/or retest results on this report meet project requirements as noted above. Last Cal. Date:Model:Make:S/N:24923 Fort Worth - Troxler 3430 01/03/2025 Perform in-place density and moisture content tests to determine degree of compaction and material moisture condition.Services: Reported To: Contractor: Greg Sutheimer with Sawyer Construction Sanchez Construction Doyle Mackey Senior Project Manager Report Distribution: (1) Sawyers Construction, Inc (TX), Randy Sawyers (1) Sawyers Construction, Inc (TX), Brandy Altonji (1) Sawyers Construction, Inc (TX), Maribel Cortez Reviewed By: Terracon Rep.: Ousainou Allen ASTM D6938Test Methods: The tests were performed in general accordance with applicable ASTM, AASHTO, or DOT test methods. This report is exclusively for the use of the client indicated above and shall not be reproduced except in full without the written consent of our company. Test results transmitted herein are only applicable to the actual samples tested at the location (s) referenced and are not necessarily indicative of the properties of other apparently similar or identical materials . CR0007, 03-31-22, Rev.8 Page 1 of 1 Exhibit 1801 Handley Ederville Rd Fort Worth, TX 76118-7102 817-268-8600 terracon.com 121 Community Park Field Density Testing A-1 Report Number: 94251218.0009 Service Date: 05/09/2025 Employee: Allen, Ousainou Scale: Refer to Drawing Test Retested / Accepted Deviation